Military Engineer Services Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_658472_2Bid Award Id
ViewTender No
865/EWS(NIT-57)/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L providing and fixing Gypsum board 6mm thick and 600x600mm in size in ceiling fixed with screw or with staples on snap grid as per manufactures instructions, complete all as specified and directed by Engr-in-charge.
280
-
-
M&L for 2nd class soft wood clean sawn as in battens for grids of ceiling & lining fixed with nails exc 13 sqcm and n exc 25 sqcm in section.complete all as specified and as directed.
780
-
-
M&L for 2nd class soft wood clean sawn as in beeding for edges of Ceiling ,lining ,or wooden flooring work fixed with nails exc 6 sqcm and n exc 13 sqcm in section.complete all as specified and as directed.
205
-
-
M&L for covered fillets of standard hard board not less than 6mm thick and up to 40mm wide and fixing with screws complete all as specified and as directed.
120
-
-
M&L 6mm (5 ply) thick veneered decorative (Knoty Pine) plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed with nails to timber frame work as wall panelling, complete all as specified and as directed.
120
-
-
M&L 6mm (5 ply) thick veneered decorative (Knoty Pine) plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed with nails to timber frame work as ceiling panelling, complete all as specified and as directed.
50
-
-
M&L French polishing on wood or wood based surface of any width or girth or any description,including cleaning and preparing the surface including a coat of wood filler o new surface with two or more coats complete all as specified and as directed.
170
-
-
M&L in repair for 9mm thick prelaminated particle board medium interior grade, prelaminated one side with decorated choice lamination & other side balancing white lamination fixed with screws to timber frame work as in wall panelling, shelves/boarding complete all as specified and as directed.
350
-
-
M&L in repair for 9mm thick prelaminated particle board medium interior grade, prelaminated one side with decorated choice lamination & other side balancing white lamination fixed with screws to timber frame work as in ceiling panelling, shelves/boarding complete all as specified and as directed.
250
-
-
Dismantling boarding / wooden flooring of any description ,fixed in any positon, complete all as specified.
150
-
-
M&L for hard wood 2nd class factory made wooden boarded floors 10mm thick and skirtings planed one side & edges tonged and grooved or rebated , including backing with thermocol sheets or as specified by manufacture all as specified and directed.
150
-
-
Dismantling floor, hearth or wall tiling including wall cement mortar bedding (But not backing ) and rubbish of premises complete all as directed.
560
-
-
M&L for vitrified ceramic tiles 10mm thick (light shade ) (square/rectangular) polished, area of each tiles not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles and screed bed with M (1:6) 15mm thick for laying floor tiles all as specified and directed.
180
-
-
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11Sqm and nexc .18 Sqm in floor etc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match the screed bed with CM (1:6) 15mm thick laying floor tiles complete all as specified and directed.
300
-
-
M&L for Glazed ceramic coloured tiles in vertical surfaces 350 x 250 x 7mm /450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match over 10mm thick CM (1:4) in dado/skirting tiles complete all as specified and directed.
80
-
-
Demolition of cement concrete in ground floor and pavings n'exc 15cm thickness (below or above ground level complete all as specified and as directed.
55.1
-
-
M&L for cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement percubic metre, thickness of concrete 25 cm or less, complete all as specified and as directed.
40
-
-
Supply only metalic floor harderner (300gm/Sqm), complete all as specified.
15
-
-
M & L for 75 mm PCC 1:3:6 type C-2 (using 20mm graded crushed stone aggregate) as plinth protection finished even and smooth with out using extra cement, complete all as specified and as directed.
55
-
-
M & L for 100 mm PCC 1:2:4 type B-1 using 20mm graded aggregate as in floor of hard standing finished even and smooth with out using extra cement all as specified.
300
-
-
M&L for Cement concrete type B-2,1:4:8 (40mm graded aggreate) 75 mm thick as in sub -floors ,sub- bases ,floors and pavings,etc.complete all as specified and as directed.
300
-
-
M & L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' for 100mm thick concrete,complete all as specified and as directed.
12
-
-
M&L forming contraction (Dummy) joints 65mm deep X 10mm wide , filled with sealing compound Grade 'A' , complete all as specified and as directed.
15
-
-
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.5 Sqm and not exceeding 4 Sqm each complete all as directed by Engr-in-charge.
28
-
-
Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed.
22
-
-
Taking down shutters of any description area exceeding 1 Sqm and not exceeding 2 Sqm each complete all as directed by Engr-in-charge.
20
-
-
S&F 2nd class soft wood plain, solid, straight chowkets and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete(Glass shall be measured Seperately) all as directed by Engr-in-Charge.
1.2
-
-
S&F for 35mm thick 2nd class soft wood plain framed paneled shutters (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, Supply and fixed to chowkats , complete all as directed by Engr-in-charge.
38
-
-
S&F for 40 mm thick Flush shutters, solid core construction ,with block board core and plywood face panels commercial type on both sides , Supply and fixed to chowkats , complete all as directed by Engr-in-charge.
32
-
-
S&F 2nd class soft wood 35 mm thick Glazed and skelton shutter, open and prapared to receive the glass, gauze etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc. (Glass / Wiremesh should be measured seperately) complete all as specified and as directed by the Engr-in-Charge..
12
-
-
S&F mild steel butt hinges, medium weight cold rolled 100mm size complete all as specified and as directed.
60
-
-
S&F stainless steel butt hinges, medium weight cold rolled 100mm size complete all as specified and as directed.
40
-
-
S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified and as directed.
45
-
-
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed.
45
-
-
S&F mild steel butt hinges, medium weight cold rolled 75mm size complete all as specified and as directed.
30
-
-
S&F 100mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified and as directed.
30
-
-
S&F 100mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed.
40
-
-
S&F in repair 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
12
-
-
S&F in repair 250mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and as directed.
20
-
-
M & L for preparing new wood & wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
210
-
-
Providing and fixing Anodised aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever
required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P.
brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
52
-
-
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc. complete all as specified
22
-
-
S&F Anodised aluminium window and ventilator shutters,including aluminium jali fixed in one side, side hung type without sash,aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150mm long (1 Nos) hinges type B-21 100mm long (2 Nos) suitable handle (1 Nos) etc. complete all as specified
26
-
-
M&L for aluminium (extruded section body) door closer hydraulically regulated designation No 3, universal type, suitable for door shutterof 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed completed all as spd and directed.
10
-
-
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
50
-
-
Hacking out old broken glass (any thick ness, size, quality or description) from wooden panes or stone, concrete or brick surrounds, glazed with oil putty or fixed with beads complete all as specified and as directed .
57
-
-
S&F in repairs 5.5mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed
45
-
-
S&F in repairs 3.0mm thick figured glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
12
-
-
S&F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples all as specified and as directed
10
-
-
Dismantling wrought iron or mild steel work of any description not otherwise provided for angle iron or flat iron as in post and guard bar or grating complete all as specified and directed by Engr-in-Charge.
5.7
-
-
Dismantling of Asbestos cement sheeting any gauge, thickness as in roof covering complete all as specified and as directed.
102
-
-
S&F Pre painted galvalumealuminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall fixed with self tapping screws as specified ( Note : Work to be executed in hanger up to height 9 mtr to 12 mtr including with the help of hydra/ crane ).
80
-
-
S&F Pre painted galvalumealuminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall fixed with self tapping screws as specified.
Note : Work to be executed in hanger up to height 9 mtr to 12 mtr, including with the help of hydra/ crane.
22
-
-
S&F Plates Fe-410W(GdeE-250) Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated, complete all as specified and as directed.
312
-
-
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe-410 Gde 250 quality A including distance pieces, cleats etc, complete all as specified and as directed.
255
-
-
Demolition of precast concrete block walling built in cement mortar including all quoins, arches , pillars etc all as specified and as directed.
10
-
-
M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonary exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:6 all as Spd, complete all as specified and as directed.
8
-
-
All as per Srl Item No 60 here-in-above but except blocks complete all as specified and as directed.
2
-
-
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed.
150
-
-
M&L for cement plastering 10mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed.
45
-
-
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair without fair extra cement complete all as specified and directed.
Note : WPC will be measured and paid separately.
180
-
-
Supply only integral liquid water proofing compound complete all as specified and directed.
6.8
-
-
M&L for preperation of new plastered wall surface of any description and applying two coat OBD over a coat of primer complete all as specified and as directed.
45
-
-
M&L for preperation of new plastered wall surface of any description and applying two coats of cement based paint complete all as specified and as directed.
180
-
-
S & F in repair Vitreous china wash down water closet (Pedestal), white (EWC) including Plastic seat cover of same colour of WC, closed patttern with flat bottom, and cover and Mild steel chromium plated hinging device complete.
2
-
-
S&F flushing cistern of PVC 10 litre. capacity with dual flushing system, white colour, valveless syphonic action type, low level, with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.
Make : Hindware or Cera (Corona) or Prayag (Vintage) equivalent from Parryware
2
-
-
S&F vitreous china premium/1st quality wash basin full pedestal, white, flat back, size 500x400 mm including pedestal, screws & plug and brackets etc. all accessories as recommended by manufacturer and incl 32mm brass CP waste coupling half thread and complete in all respect as per manufacturer's instructions and taking down existing of any description/size all as specified.
Make : Hindware (WHB-Cleo (Cat No.- 10012&11027), Waste Coupling-Cat No.- F850023 (Economy Model), or equivalent from Parryware/Cera as approved by AO
2
-
-
S & F of ISI marked Pillar Tap of 15mm bore dia, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
2
-
-
S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified.
2
-
-
M&L for preparing bituminous surfaces of road and marking 2.5 mm thick centre lines, stop lines, dashes ,arrows etc and the like n. exc 15cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed.
255
-
-
Taking down existing unserviceable/old copper / alluminium point wiring (light,fan,socket,power point ) complete excluding fitting fixtures such as switches ,ceiling roses, pendant/angle holders regulators, sockets etc complete all as specified and directed
90
-
-
M&L for point wiring for one light point or fan point controlled by one light/exhaust fan controlled by one way switch with PVC insulated FRLS copper conductor stranded cable of size 1.5 sqmm and including PVC casing/caping terminated in existing sunk CI/pressed steel terminal boxes for fixing and 1.5 sqmm PVC insulated copper wire as earth wire connected to earth wire connected to earth folly and 3.0mm thick plastic laminated sheet cover all as specified and directed by Engr-in-Charge. (a) One Light point /Fan controlled by one way switch
40
-
-
All as per item No 75 here in before but for one switch socket outlet 6 Amp 230 volts point on independent board.
30
-
-
All as per item No 75 here in before but for one switch socket outlet 6 Amp 230 volts point on same board.
20
-
-
M & L for point wiring with 4 sq mm PVC insulated, unsheathed single core stranded copper conductor 1100 Volt grade in PVC concealed Conduit pipe on wall /floor etc with all accessories of suitable size MS/Pressed steel terminal boxes 1.6 mm thk with bakelite sheet cover (hylum) 3mm thick /PVC Gang box for mounting switch, socket, Cup washers complete with all accessories for one 6 pin 15 Amp socket outlet point on independent board including 4 sqmm PVC insulated copper conductor in green colour common earth and connecting to earth dolly all as specified.
40
-
-
S&F in replacement switch piano flush button single pole one way 6 Amp, 240 Volts complete all as specified and directed.
90
-
-
S & F in replacement switch socket outlet, 2 in 1,5 Pin, 6 Amp 240 volt flush type complete all as specified and directed.
50
-
-
S&F in replacement switch socket combination piano flush button single pole one way, multipurpose, 5pin ,5 and 16 Amp, 240 Volts complete all as specified and directed.
40
-
-
S & F in replacement ceiling rose surface Bakelite three terminals complete all as specified and directed.
20
-
-
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 12 Ways all as specified and directed by Engr-in-Charge.
8
-
-
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 08 Ways all as specified and directed by Engr-in-Charge.
15
-
-
Supply and fix in replacement of MCB SPN 63 Amp 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge.
23
-
-
Supply and fix in replacement of MCB SP 6-32 Amps. 240 Volts 50 HZ complete all as directed.
45
-
-
Supply and Fixing only in Replacement LED light fitting 1X20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
50
-
-
Supply and fixing in repalcement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
12
-
-
Supply and fixing in repalcement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete
20
-
-
Supply and fix in repair plug top 15A, 240 volts complete all as specified and directed.
25
-
-
Supply and fix in repair plug top 5A, 240 volts complete all as specified and directed.
5
-
-
Supply and fix in repair LED Lamp 12 watt complete all as specified and directed.
40
-
-
M&L for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for batten fittings complete all as directed by Engr-in-charge.
10
-
-
S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
20
-
-
S&F Buzzer Ding Dong AC.230 Volts single pole complete all as specified and directed.
5
-
-
Taking down old unserviceabole exhaust fan and supply and fix in repair exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
8
-
-
Supply and fixing LED attractive and decorative strip type Warm lights 11/15 watts,system Lumen Efficiency110 Lm/W operating voltage between 140-270 Vac, power factor more thn 0.90% LED driving current70% of rated maximum forward current, THD less than 20% CRI more than 80%, Luminaire intergal driver with 2 KV surge protection, overload protection,No load protection and BIS marking (Ref no for Driver), Driver certification IEC6437-2-13 IS (15885) Over all electrical Eficiency more than 90%, driver electrical efficiency will be85%. (Note:- Each strip have minimum 5 Mtr lambai, seperate led driver and seperate point wiring. The point wiring and swithes measured seperately.) all as specified and directed.
4
-
-
M & L for Sub main wiring with two run of 2.50 Sqmm (2x2.5 Sqmm) 1100 volts grade single core FRLS PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x2.5 sq. mm + 1x 2.50 sq. mm unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 1.50 Sqmm (1x1.50 sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge.
Note:- 2 runs of 2.50 Sqmm (2x2.50sqmm), one run of 1.50 Sqmm (1x1.50 sqmm) cable and one metre of PVC casing caping will be measured as one unit.
200
-
-
M & L for Sub main wiring with two run of 10.00 Sqmm (2x10 sqmm) 1100 volts grade single core FRLS PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x10.0 sq. mm + 1x 6.0 sq. mm unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6.00 Sqmm (1x4sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge.
Note:- 2 runs of 10 Sqmm (2x10 sqmm), one run of 6 Sqmm (1x6 Sqmm) cable and one metre of PVC casing caping will be measured as one unit.
50
-
-
Taking down old unserviceable TPN DB of any type and supply and fix in replacement VTPN DB 4 way along with MCCB 160 Amp 4 Pole, 415 Volts, 50 HZ double door surface mounted complete all as specified and directed.
1
-
-
M&L for Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying UG cable in trenches on plan and n exc 1.5 m in depth in any type of soil and getting out all as specified and directed by Engr-in-Charge.
108
-
-
M&L for Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc. 25m, complete all as specified.
55
-
-
M&L for Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the strating point, complete all as specified.
53
-
-
M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, complete all as specified. Note : Punned thickness of 18 CM will be measured and paid for
41
-
-
Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 flate size 250mm x 150mm x 40mm, complete all as specified and directed
2666
-
-
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 240 Sqmm 3.5 core laid in trenches or passing through pipes ducts or fixed to walls/poles complete all as specified.
100
-
-
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 70 Sqmm 3.5 core laid in trences or passing through pipes ducts or fixed to walls/poles complete all as specified.
300
-
-
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
5
-
-
Supply and fixing LED high bay light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
5
-
-
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
5
-
-
Taking down old unserviceable feeder pillar box and supply and fix in replacement feeder pillar box of suitable size with incommer MCCB of cpacity 160 Amps, 415V , with 4 Nos aluminium bus bar strip along with 14 Nos MCB SPN 63 Amps, 240 Volts, C type with Din rail for mounting and necessary wiring for MCB,s complete size all as specified and directed.
1
-
-
Taking down old unserviceable feeder pillar box and supply and fix in replacement feeder pillar box of suitable size with incommer MCCB of cpacity 100 Amps, 415V , with 4 Nos aluminium bus bar strip along with 14 Nos MCB SPN 63 Amps, 240 Volts, C type with Din rail for mounting and necessary wiring for MCBs complete size all as specified and directed.
1
-
-
Taking down old unserviceable feeder pillar box and supply and fix in replacement feeder pillar box of suitable size with incommer MCCB of cpacity 63 Amps, 415V , with 4 Nos aluminium bus bar strip along with 14 Nos MCB SPN 63 Amps, 240 Volts, C type with Din rail for mounting and necessary wiring for MCB,s complete size all as specified and directed.
1
-
-
Supply and fixing in replacement of MCCB Triple Pole 630 Amp 415 Volt rupturing capacity not less than 25 KA complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of MCCB Triple Pole 400 Amp 415 Volt rupturing capacity not less than 35 KA complete all as specified and as directed.
10
-
-
Supply and fixing in replacement of MCCB Triple Pole 250 Amp 415 Volt rupturing capacity not less than 35 KA complete all as specified and as directed.
6
-
-
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed by Engr-in-Charge.
15
-
-
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 300 Amps complete all as specified and directed by Engr-in-Charge.
10
-
-
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps complete all as specified and directed by Engr-in-Charge.
5
-
-
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable) and accessories suitable for XLPE armoured, aluminum conductor cable of size upto 70 sqmm 3.5 core complete all as specified and directed by Engineer-In-Charge.
5
-
-
Evaluation Notes How It Works ?