Military Engineer Services Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 45,720Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680496_1Tender No
GEAF/T-16/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking out old unserviceable compressor from split type Air Conditioner (All weather) of capacity 2 TR and supply,& fixing, commissioning and testing of new compressor complete with connection incoming and outgoing required at site all as specified. Make:- Voltas/ carrier/ LG/Videocon)
5
-
-
Taking out old unserviceable compressor from split type Air Conditioner (All weather) of capacity 1.5 TR and supply,& fixing, commissioning and testing of new compressor complete with connection incoming and outgoing required at site all as specified. Make:- Voltas/ carrier/ LG/Videocon)
5
-
-
Taking out old unserviceable compressor from window type Air Conditioner (All weather) of capacity 1.5 TR and supply,& fixing, commissioning and testing of new compressor complete with connection incoming and outgoing required at site all as specified. Make:- Voltas/ carrier/ LG/Videocon)
5
-
-
M&L for Taking out old unserviceable compressor from Deepfreezer/upright chiller/freezer of any type of any size and supply & fixing, commissioning and testing of new compressor complete with connection incoming and outgoing required at site all as specified. Make :- cell frost/vest frost/blue star/voltas.
5
-
-
Supply & fixing in replacement of outdoor unit fan motor single phase AC supply 230 volts 50 HZ for split type AC (All weather) 1.5 TON as per existing make and size complete all as specified and directed by Engr-in-Charge.
4
-
-
Supply & fixing in replacement of outdoor unit fan motor single phase AC supply 230 volts 50 HZ for split type AC (All weather) 2.0 TON as per existing make and size complete all as specified and directed by Engr-in-Charge.
4
-
-
Supply & fixing in replacement of condensor fan motor single phase AC supply 230 volts 50 HZ for wimdow type AC 1.5 TON as per existing make and size complete all as specified and directed by Engr-in-Charge.
2
-
-
Supply and fixing in replacement of suction valve spring loaded type for split type AC 1.5 TR complete all as specified and directed by Engr-in-Charge..
5
-
-
Supply and fixing in replacement of discharge valve for split type AC 1.5 TR.
5
-
-
Supply and replacement of spares parts of window type and split type AC (All weather) 1.5 TR as under :-
-
-
-
Starting relay.
5
-
-
Overload protector.
5
-
-
Starting capacitor 120/150 mfd.
5
-
-
Running capacitor 6 mfd.
5
-
-
Running capacitor 45 mfd.
5
-
-
Thermostat.
5
-
-
S& F in replacement of PCB with remote control for window type AC (All weather) of cap 1.5 TR as per existing make complete all as specified and directed by Engr-in-Charge.
4
-
-
S& F in replacement of PCB with remote control for Split type AC (All weather) of cap 1.5/2 TR as per existing make complete all as specified and directed by Engr-in-Charge.
4
-
-
Taking out of unserviceable automatic voltage stabilizer of capacity 4/5 KVA and transporting it to electrical repair shop for checking its serviceability and making complete functional to give constant rated voltage after repalcing all unseviceable parts and refixing it completely on site complete all as specified and directed by Engr-in-Charge.
4
-
-
Takind down old cracked UNSV copper pipe split line and refixing with new insulated copper split line pipe 50mm dully connected with end of indoor and outdoor unit with suitable nut, bolts or weld as required on site for split type airconditioner complete all as specified and directed by Engr-in-charge.
80
-
-
Taking down of exhaust fan single phase of any size and type complete all as specified and directed.
30
-
-
M&L for Rewinding of ceiling fan 1200mm sweep single phase 230 volts, 50 c/s any make and type with appropriate gauge super enameled copper winding wire with allied insulation winding material, varnishing with air drying insulation varnish including fixing of any item found damaged/unserviceable i.e capacitor of appropriate cap, rubber pads etc and testing complete after rewinding and assembling. Note: Capacitor, rubber pads, etc if any replaced, shall be measured separately under respective items complete all as specified and directed by Engr-in-Charge..
10
-
-
M&L for Rewinding of exhaust fan single phase 230 volts, 50 c/s 450 mm sweep, any make and type with appropriate gauge super enameled copper winding wire with allied insulation winding material, varnishing with air drying insulation varnish including fixing of any item found damaged/unserviceable i.e capacitor of appropriate cap, rubber pads etc and testing complete after rewinding and assembling. Make of winding wire: Devidyal/Atlas. Note: Capacitor, rubber pads, etc if any replaced, shall be measured separately under respective items complete all as specified and directed by Engr-in-Charge..
10
-
-
All as per srl item No 20 above but for exhaust fan of size 300mm sweep complete all as specified and directed by Engr-in-Charge..
10
-
-
S &F ball bearing suitable for exhaust fan 450mm sweep to replace the unserviceble ball bearing of fan motor complete all as specified and directed. Make: SKF/NBC
5
-
-
S &F ball bearing suitable for exhaust fan 300mm sweep to replace the unserviceble ball bearing of fan motor complete all as specified and directed. Make: SKF/NBC
5
-
-
S &F ball bearing suitable for ceiling fan 1200mm sweep to replace the unserviceble ball bearing of fan motor complete all as specified and directed. Make: SKF/NBC
5
-
-
S & F of only capacitor 4.0 mfd 50 c/s oil filled complete all as specified and directed by Engr-in-Charge.. Make: Usha/Universal
10
-
-
S & F of only capacitor 2.5 mfd 50 c/s oil filled complete all as specified and directed by Engr-in-Charge.. Make: Usha/Universal
10
-
-
Supply & fix only capacitors with new capacitors, 3.25 mfd, 50Hz, AC 220/440 Volts complete all as specified and directed.
20
-
-
M&L in Replacement of old fan regulators 5 step type with new fan regulators, stepped type electronic, piano switch type dully fixed on the existing laminated sheet/ board etc, complete all as specified and directed.
30
-
-
S & F in replacements of exhaust fan motor 450mm complete all as specified and directed. Make:Bajaj/Havells or equivalent make
5
-
-
S & F in replacements of exhaust fan motor 300mm complete all as specified and directed. Make:Bajaj/Havells or equivalent make
7
-
-
S & F in replacements of exhaust fan motor 250mm complete all as specified and directed. Make:Bajaj/Havells or equivalent make
5
-
-
S & F hole fastener complete set 4 inch long complete all specified and directed.
100
-
-
S & F hole fastener complete set 6 inch long complete all specified and directed.
100
-
-
S & F in replacements of exhaust fan Louver Shutter Metallic body for 450mm sweep exhaust fan complete all as specified and directed.
5
-
-
S & F in replacements of exhaust fan Louver Shutter Metallic body for 300mm sweep exhaust fan complete all as specified and directed.
8
-
-
S & F in replacements of exhaust fan Louver Shutter Metallic body for 250mm sweep exhaust fan complete all as specified and directed.
8
-
-
S&F in repair of DOL starter for 3 to 6 HP 3 Phase motor, of relay range 9 to 15 Amp, with single phase protection complete all as specified and directed by Engr-in Charge. Make L&T, Seimns, ABB.
4
-
-
S&F in repair of PVC copper Conducter 3 Core 6 Sqmm form starter to motor Flat/ Round complete all as specifed Make Finolex, Polycab, Havells.
600
-
-
S&F in repair of PVC copper Conducter 3 Core 10 Sqmm form starter to motor Flat/ Round complete all as specifed Make Finolex, Polycab, Havells.
400
-
-
S& F in replacment in repair Automatic volatage stablizer of Copper wound of volatage range between 140 V to 260 V with tripping mechanism having Voltmeter and Amp meter with digital display of capacity of 5 KVA complete all as specified and directed Make Microtek, V-Guard, Servokon.
3
-
-
Servicing of Hot Water Boiler , Disconnecting electric drain out water opening of burner chamber boiler assembly, all accessories and mounting taking out helical coil of make-Alfa Therm hot generator 100000/200000 K Cal/Hrs, cleaning of combustion chamber repairing/replacement of any unserviceable parts as specified in each it complete all as specified and directed. ms mentioned. Note :- The Job shall be carried out after every 2 Month of Boiler run and shall be measured and paid separately, no of times carried out during entire period of contract
15
-
-
S&F in replacement sheet metal, single pole and neutral enclosure (factory made) with socket plug top and MCB, with a 2-pin and earth plug and socket, 240 volts, 20 amps, for AC point, complete all as specified and as directed.
5
-
-
Repair of hot water boiler of capacity 100000 /200000 K cal/Hr including repair/replacement of following parts from item no 43.01 to 43.14 to make it functional as specified and directed by Engr-in-Charge.
-
-
-
Replacement of complete helical coil assembly.
1
-
-
Replacement of input ignition transformer 220 Volts of output 11 KV to 14 KV.
2
-
-
Replacement of gasket suitable for hot water boiler.
3
-
-
Replacement of sequence controller for hot water boiler.
1
-
-
Replacement of refectory plate as per sample.
2
-
-
Replacement of Pressure Gauge - 0 to 10 Kg/Cm square suitable for hot water boiler.
2
-
-
Replacement of Photo cell for hot water boiler.
2
-
-
Supply and Fixing in replacement motorised barrel pump of capacity 0.5HP, 2850 RPM , Single phase with rubber hose pipe 15 RM complete with all accessories complete all as specified and directed by enger in charge. Make : Bharat, Kirloskar
4
-
-
Replacement of un-serviceable gate valve of capacity 50 mm Dia suitable for hot/cold water Make Leader/Surya Parkash ISI marked
4
-
-
Replacement of un-serviceable gate valve of capacity 40 mm Dia suitable for hot/cold water Make : Leader/Surya Parkash ISI marked.
4
-
-
Replacement of solenoid valve for hot water boiler.
4
-
-
Replacement of fuel TPL pipe to burning assembly for hot water boiler.
2
-
-
Replacement of fuel filter assembly 1/2 Ltr capacity with filter.
15
-
-
Replacement of Burner Pump
2
-
-
S&F in repair/ Replacement of Burner of Boiler for 1 L K cal make Eco flame or Equivalent or as per sample
2
-
-
S&F in repair/ Replacement of Starting Panel of Boiler for 1 L K cal make as per sample Rapid Cool
1
-
-
S&F in repair/replacement of Electronic Buzzer for Hot Water Boiler of 1 l Kcal.
2
-
-
S&F in repair/replacement of MNX 9 Contactor type for Hot Water Boiler of 1 l Kcal.
3
-
-
S&F in repair/replacement of Bimetallic Relay of 3 to 5 Amp for Hot Water Boiler of 1 l Kcal.
2
-
-
S&F in repair/replacement of Single Phase Preventer for Hot Water Boiler of 1 l Kcal.
3
-
-
S&F in repair/replacement of Control Module for Hot Water Boiler of 1 l Kcal.
1
-
-
Supply and fixing in replacement, testing and commissioning of centrifugal pump set of capacity 3 HP, 3 Phase,2880 RPM, Head 22 to 33m, size 50x40 mm, discharge 4.50 to 2.50 l/s as specified and directed by Engr-in-Charge.
2
-
-
Supply and fixing in replacement, testing and commissioning of centrifugal pump set of capacity 5 HP, 3 Phase,2880 RPM, Head 22 to 33m, size 50x40 mm, discharge 4.50 to 2.50 l/s as specified and directed by Engr-in-Charge.
2
-
-
S&F in replacement Complete Insulation wrapping for the tank in all boiler with 75 mm thick bounded mineral wool with wire mesh including provision of aluminium foil cover complete all as specified and directed by Engr-in-Charge.
2
-
-
Rewinding of Pump motor of capacity 5 HP with super enamelled copper & wire of same gauge etc using best quality of insulation materials turning polishing of motor shaft by machining, replacement of bearing - 02 Nos including all necessary repair work to make the equipment functional, as directed by Engineer-in-Charge.
1
-
-
Rewinding of pump 3 HP with replacement of different unserviceable parts including all necessary repair work to make the equipment fully functional, as directed by Engineer-in-Charge.
Note :-Spare parts to be replaced for this item will be measured and paid separately.
1
-
-
S&F in replacement of following item No from 56.01 to 56.06 as required for overhauling/repairing the Centrifugal pump complete as per item no 54 & 55 above
-
-
-
Impeller
1
-
-
Pump shaft
2
-
-
Thrust Bearing
2
-
-
Water seal
2
-
-
NRV
1
-
-
Bushing
4
-
-
Taking down of existing MS Sheet hot water storage 1500 /2000 Ltrs tubular tank from the mounting and checking it for any leakages, damages etc and making on site arrangement for repair of tank by welding with suitable size MS plate making it completely leak proof and refixing the same after wrapping with insulation at the existing height and dully fixing with fastener, nuts and bolts etc complete all as specified and directed by Engr-in-Charge.
5
-
-
Repair/Attending break down of Boiler to make completely functional in all respect to with out replacing spare parts complete all as specified and as directed.
Note:- The Item include any type of breakdown and sundry item cost deemed to be include in the quoted rate.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%