Military Engineer Services Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 3,12,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_656595_2Tender No
CEAFU-01-2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(e) 25 mm thick Expansion joints through the depth of PQC shall be made as per intervals specified by Engineer-in-charge. The joints shall be filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound of Grade ‘B’.
(f) Doors: Supply and fixing of Sandwich PUF panel 60 mm thick (42 Kg per cum of density) with 0.5 mm thick Pre-coated (Approved colour) Galvalume sheets of yield strength 240 Mpa on both inner and outer side with zinc coating mass of 120 GSM.
(g) Heat Insulation between Sliding Doors: Supply and fixing of 50 mm thick or as per design and 300 mm wide gasket made out of rubber or other synthetic material fixed with suitable Aluminum beading and screwed to sliding door panel between overlap of the door to provide heat insulation from inside to outside the door and Vice –Versa.
(h) Supply, Installation, testing & commissioning of motorized door for remote operation of leaves of hanger doors from both ends including control system wire/ cables, motors, gear mechanisms, safety arrangements for motorized operations etc. The arragements may include the following apart from other equipments for efficient opertaion.
(i) Three phase electric motors of min capacity 3HP.
(ii) The drive transimission between the motors and drive wheel shall be through an efficient gear box of speed 8 to 10 meter/ min for door movement.
(iii) The eletric opertaion of each door shall be carried out from control panel mounted at the extreme end of the door opening inside the building. The operation shall have to keep the open and close push button pressed to provide arrangement enable the door automatcially open / close through the control power cut on /off through limit switches
(iv) An emergency STOP button (STAY-PUT-TYPE) shall also be provided on the control pannel.
(v) In case of power failure the door to be operated manually by disengaging the gearbox.
(vi) Each door control panel shall be provided with flashing light that shall start and continue to operate during the time the door is working / closing / opening.
-
-
-
Notes:- (a) All necessary arrangements for movement of doors including gearbox, cables for electric supply to motors, panels and any other arrangement required for smooth functioning of motors and as directed shall deemed to be included in the quoted rates. No claims whatsoever shall be entertained at the belated stage. (b) The lump sum quoted rates shall deemed to be include all arrangement/ requirements for satisfactory opertaions including safety arragements and shall include 3 years maintenance for satisfactory operations.
(j) PAINTING: All new steel surfaces including PUF panel shall be painted with two coats of acrylic Emulsion paint of approved make over a coat of steel primer. The work shall be executed at a height upto 10 metre. The quoted rate are inclusive of necessary scaffolding and formwork required to execute the work. Therefore, this aspect shall be considered by the bidders before quoting the rates for this item. No claims whatsoever shall be entertained at the belated stage. The painting of all surfaces shall be done by spray painting only.
-
-
-
(k) Camouflage Painting : The outer side face of sliding gates of Blat Pen 07 and 08 shall be painted in Camouflage pattern by applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS : 15489 : 2004. The Paint shall be Alkali and Fungal resistance, dust resistance of approved shade with silicon additives @ 1.43 Liter/10Sqm over and including priming coat @ 0.90 Liter/10Sqm all as specified and as directed by Engineer-in-Charge. The work shall be executed at a height upto 10 meter. The quoted rate are inclusive of necessary scaffolding and formwork required to execute the work. Therefore, this aspect shall be considered by the bidders before quoting the rates for this item. No claims whatsoever shall be entertained at the belated stage.
-
-
-
(l) The design parameters for incorporation in the provn of sliding doors and heating facility works are furnished as under:-
a. Load shall be as per IS 875 Part I to V latest revision.
b. Structural steel design shall confirm to IS 800 latest revision in limit state design method. c. RCC design shall confirm to IS-456 latest revision read in conjunction with IS-1893 and IS 13920 latest revision.
d. The work is being executed in Leh. Hence the snow load shall confirm to the IS 875 part-IV and snow load chart along with local practices for snow loads in Leh, whichever produces critical stresses.
e. The sliding doors shall have an inbuilt fail-safe mechanism to ensure that they do not fall off the rails due to failure.
f. The sliding doors shall also offer airtight space to the existing blast pen for which the door propose to close.
-
-
-
Total amount of Schedule 'A' PART-I (BUILDING WORK)
-
-
-
Total amount of Sch 'A' PART-II (SEC-I)( CENTRAL HEATING SYSTEM)
1
535562
-
Total amount of Sch 'A' PART-II (SEC-II)( CENTRAL HEATING SYSTEM)Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
Supply, installation,testing and commissioning of diesel fired air space heater of capacity 1,50,000 Kcal/Hr with 04 Nos flue gas passes, at 80 degree celcius outlet air flow not less than of 14000 m3/hr with combustion chamber with outer jacket module duly insulated,smoke tubes,automatic monoblock burner assembly, control panel with sequence controller,thermal overload relays,starter with MCBs, contactor, relay, photocell for flame failure HT transfer electrode,blower assembly, electric control panel with selector switch, indication lamp, alarm hooter, digital temperature controller, centrifugal blower with electric motor driven of suitable capacity with belt and pulley , powder coated casing flanged ductable type inlet and outlet suitable for operation on 50Hz 3 phase 415 volt AC supply comprising of the followings:- (i) Cylindrical diesel tank of capacity as per manufacture instructions complete with inter-connecting piping with valve, fuel filter assembly, MS mounting legs and level indicator. Note: (i) PCC for foundation of space heater shall deemed to be included in the quoted rate. (ii) To maintain the inside desired temperature at 20°C +/- 2°C (degree Celsius) and relative humidity at 45% +/- 10% when ambient temperature drops to -25°C.
(iii) The supply and fixing of central heating system including the duct system shall be undertaken under strict supervision of technician from the approved manufacturer.
(iv) Any other technical requirement to improve the efficiency of heating system shall deemed to be included in the quoted rate of this item.
4
-
-
NOTE :-( i) All Accessories required for smooth opertation of Space heating system shall deemed to be included in the quoted rate.
(ii) The rating of space heater has been estimated on the basis of desired human comfort conditions in the conditioned space,however if the rating is revised upwards subsequently no claim in this reqard shall be admissible therefore the bidder is advised to visit the site before quoting the rate for this item.
(iii) Two space heater have been considered for conditioned space of each blast pen out of which one will act as standby.
(iv) Seperate air distribution through duct has to be done from each space heater to be installed on the opposite sides of the blast pen.
(v) Please note that anything missed out above and required for smooth functioning of the plant to achieve the desired smooth functional condition shall deemed to be included in the quoted rates. No Devation Order on plus side/ claim shall be admissible in this regard at the later stage.
(vi) The installation of space heater including ducting shall be done under the supervision of rep of the OEM of air space heater.
-
-
-
Supply & fixing of Chimney for exhaust of effluent flue gases (burnt smoke) of height 4 metre with minimum diameter 150mm , fabricated of B class MS pipe having minimum thickness 4mm, including canopy at the outlet of the chimney, flange to fix the chimney with the space heater complete all as specified and as directed by the Engineer-in-charge. Notes :- (a) The item shall be complete with the mounting/fixing arrangement all as specified by the space heater manufacturer including the dia of the exhaust flue gas chimney as per the design and specification of space heater installed-01 Nos. (b) The space heater shall be directly connected to the chimney. (c) The mechanical stability of the chimney has to be ensured by providing proper supports
4
-
-
Ducting work :-
Supply, installation and testing of Site fabricated GI sheet metal ducts, as per IS: 655 and IS:277 in accordance with the approved shop drawings and as required by the specifications for the following sizes of ducting work complete all as specified and as directed by the Engineer-in-charge.
-
-
-
(a) 20 Gauge Thickness
502
-
-
(b) 22 Guage Thickness
166
-
-
Notes for Ducting work :- (a) The Supply Duct should be 1 meter from the Finished floor level by providing bracket support and the spacing between Supply Duct and Return duct should be of minimum 0.5 meter . (b) The cost for Cutting of holes for ducting, making good the surface,cost of Angle fastener, nuts, bolts etc. shall deemed to be included in the quoted rates for the respective item
-
-
-
Duct Insulation :-
Supply, installation, testing and commissioning of fire retardant nitrile insulation material of thickness 19 mm of thermal conductivity as per specification (Joint shall be sealed with self adhesive tape) including Aluminum clading sheet wrapped all around of 5 mm thickness minimum complete all as specified and as directed by the Engineer-in-charge.
668
-
-
Supply Air Grilles/ Diffusers :-
Supply, installation, testing and balancing of powder coated Extruded Aluminium supply air Grilles/Diffusers with volume control dampers in accordance with the approved shop drawings and specifications complete all as specified and as directed by the Engineer-in-charge.
5
-
-
Material and labour for LT distribution panel, made out of 3.15 mm thick MS sheet, powder coated, dust & vermin proof, IP-66 Protection, Outdoor type factory made cubical totally enclosed type with front and rear door opening as per engineering practice provided with locking arrangement for opening of panel with provision of seperate chamber in upper part to enclose Copper busbar of capacity 200 Amps on epoxy insulators in horizontal position and stepped manner with min 20cm distance between busbars & panel body and 06 Nos separate chambers of adequate size embedded in 40mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate), on angle iron of size 40mmx40mmx6mm with footing 30 cm clear space between bottom of panel and flooring including all accessories prewired with insulated copper wires of suitable size. The panel shall compromise of the following fittings and fixture: INCOMING : (i) MCCB Four pole 160 Amps Icu =36 KA at 415 volts with microprocessor release & fixed magnetic setting for short circuit protection - 01 Nos with adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and Class II front face with positive break indication with double break contacts -01 Nos
1
-
-
OUTGOING (i) MCCB Four pole 63 Amps Icu =16 KA at 415 volts with thermal magnetic release - 05 Nos with adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and Class II front face with positive break indication with double break contacts. (ii) MCB SPN 40 Amp 10 KA - 02 Nos. (iii) Indicating lamps LED type (RYB). (iv) Digital Voltmeters of size 96mm X 96mm -01 No (v) Digital Ammeters of size 96mm X 96mm with suitable CT ratios -01 Nos
-
-
-
Material & labour for cutting existing road/Hard Rock/ PCC hard Standing/ pavement/ drain for taking out / laying of undergroung GI pipe light grade of size 80mm dia for laying of cable including necessary earth work and making good to match with the existing surface with PCC work in type B2 (1:2:4) (using 40mm graded crushed stone aggregate) complete all as specified and as directed by Engineer-in-charge. NOTE- The cost of GI pipe light grade of size 80mm dia and Plain Cement Concrete, if required on the site shall deemed to be included in the quoted rates for this item.
10
-
-
Total amount of Schedule 'A' PART-II (Sec-II) (Central heating sysyem)
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%