Smart City Thiruvananthapuram Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Smart City Thiruvananthapuram Limited Tender

Works
Eprocure
Opening Date28 Dec 2020
Closing Date21 Jan 2021
Tender Amount₹ 23,34,47,460 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

387.26

-

-

... More
Disposal of excavated earth by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more

433.52

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

504.85

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations,footings, bases for columns

5.68

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

19.3

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

298.24

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,landings, balconies and access platform

150.51

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,girders bressumers and cantilevers

100.4

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers,Abutments, Posts and Struts

23.64

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

15.06

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more

17050.77

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

143.98

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM1:6 ( 1 cement : 6 coarse sand ) etc complete

10.5

-

-

... More
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

133.4

-

-

... More
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM1:6 ( 1 cement : 6 coarse sand) etc complete

50.11

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

114.83

-

-

... More
Providing and fixing ball bearing for rolling shutters.

68

-

-

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

5506.41

-

-

... More
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

730.8

-

-

... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

141.78

-

-

... More
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.

141.78

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1139.43

-

-

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

99.38

-

-

... More
Providing and laying Vitrified anti skid floor tiles of size 300 x 300 mm (thickness to be specified by the manufacturer),with water absorption less than 0.08% and conforming to IS: 15622, of approve make, in colours and shades, laid on 20 mm thick cement mortar 1:4(1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg /sqm including grouting the joints with white cement and matching pigment etc.complete.

190.51

-

-

... More
Providing and fixing mineral fibre false ceiling tiles at all heights of size595X595mm of approved texture,design and pattern. The tiles should haveHumidity Resistance (RH) of 99%, Light Reflectance ?85%,ThermalConductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6&7)in true horizontal level suspended on interlocking T-Grid of hot dipped allround galvanized iron section of 0.33mm thick (galvanized @120 gsm )comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32mm of length 600 mm to form grid module of size 600x600 mm suspendedfrom ceiling using galvanized mild steel item (galvanised@80gsm) 50 mmlong 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2mm, spaced at 1200 mm centre to centre along main ‘T’. The system shouldrest on periphery walls /partitions with the help of GI perimeter wall angle ofsize24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall withhelp of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S.screws. The exposed bottom portion of all T-sections used in false ceilingsupport system shall be pre-painted with polyester baked paint, for all heights.The work shall be carried out as per specifications, drawings and as perdirections of the engineer-in-charge.With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)

1141.69

-

-

... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

1605.76

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

4883.61

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

4883.61

-

-

... More
Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

732.53

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

301.34

-

-

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

4151.09

-

-

... More
9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

3277.86

-

-

... More
Supply and installation of segregation bin made up of G I sheet of 1mm thick, the size should not be less than 1.80m x 0.60m x 1.5m including finishing etc complete as per the direction of Engineer in charge

6

-

-

... More
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

36.64

-

-

... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

2466.1

-

-

... More
Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet

123.31

-

-

... More
Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc.,disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

79.12

-

-

... More
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

1183.87

-

-

... More
Taking out or dismantling MS or GI grills and handrails including stacking within 50 metres lead as per the direction of Engineer in charge.

1764.92

-

-

... More
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

155.03

-

-

... More
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.Note -item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.

155.03

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

1154.77

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

1138.2

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

113.82

-

-

... More
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/Gypsum work by providing weather/structuralnon sag elastomeric PU sealant over backer rod of approved quality as perarchitectural drawings and direction of Engineer-in-charge complete,complying to ASTM C920, DIN 18540-F & ISO 11600Upto 5 mm depth and 5 mm width

312

-

-

... More
Supplying and fixing 200 mm Aluminium aldrop

31

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm

31

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

31

-

-

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete:125 mm

62

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

31

-

-

... More
Providing and mixing integral crystalline admixture for waterproofing treatment toRCC structures like basement raft, retaining walls, reservior, sewage & watertreatment plant, tunnels / subway and bridge deck etc.. at the time of transportingof concrete into the drum of the ready-mix truck , using integral crystalline admixture@0.80% (minimum) to the weight of cement content per cubic meter of concrete)or higher as recommended by the manufacturer's specification in reinforced cementconcrete at site of work. The material shall meet the requirements as specified inACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%,compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostaticpressure. The crystalline admixture shall be capable of self-healing of cracks up toa width of 0.50mm. The work shall be carried out all complete as per specificationand the direction of the Engineerin-charge. The product performance shall carryguarantee for 10 years against any leakage.

127.33

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm.

317.54

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm.

306.32

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

8.05

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations,footings, bases for columns

8.64

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

14.4

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete

16.8

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

1152.08

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

3538.75

-

-

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

1327.33

-

-

... More
Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi models location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

72

-

-

... More
Providing and fixing galvalume sheets ridges and or hips which is matching to the tile profile sheet, 60 cm overall width, fixed with Stainless steel self drilling screw etc complete of approved make, colour and thickness as per the direction of Engineer in Charge

37.35

-

-

... More
Supplying and fixing 0.45 mm thick galvalume tile profile sheets of approved make and colour over the framework already erected, sheets fixed to the frame using special stainless steel extrusions, including all fasteners fixtures as per site requirement, applying silicone sealent wherever necessary so as to make the roof water tight at all heights as per manufacturer's Specifications and as directed by Engineer-in-Charge.

113.17

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

106.16

-

-

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

78

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

78

-

-

... More
Finish walls with Acryllic Smooth exterior paint of required shade:Old work ( Two or more coats applied @ 1.67 ltr/10 sqm) on existing cement paint surface

78

-

-

... More
Providing and fixing aluminum sections to the false ceiling work, Aluminum sections shall be smooth,rust-free, straight, mitered and joined mechanically where ever required including stainless steel screws,all complete as per the drawing and as per the direction of Engineer in charge.

370.02

-

-

... More
Providing and fixing Eco-solvent Roland print with lamination clear sticker to the ACP sheet including all necessary fittings and supporting as per the drawing and as per the direction of Engineer in Charge.

1.5

-

-

... More
Providing and fixing Retro-reflective sticker letters to the ACP sheet including all necessary fittings and supporting as per the drawing and as per the direction of Engineer in Charge.

3

-

-

... More
Providing and fixing acrylic sheet having 4mm thick to the existing framework including all necessary fittings etc. complete as per the drawing and as per the direction of Engineer in charge.

14.4

-

-

... More
Providing and fixing with 3mm thick Aluminum Composite Panel sheet having 0.25mm thick aluminum coating on both sides, to an existing framework fixed to the truss members for Ceiling and Cladding. The joints on the ACP sheet sealed with silicon sealant and aluminum beading, including all staging,scaffolding, supports, etc. complete., as per the drawing and as per the direction of Engineer in charge.

74.41

-

-

... More
Providing and fixing high-Pressure Laminated panel boards having 6mm thick, to an existing framework fixed to the truss members for Ceiling and Cladding. The joints on the panel board sealed with silicone sealant, including all staging, scaffolding, suports etc. commplete., as per the drawing and as per the direction of Engineer in charge.

104.71

-

-

... More
Supply and installation of Fibre Big pair Litre bin of 120 litre capacity including all rates etc complete as per the direction of Engineer in charge.

3

-

-

... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

1970.26

-

-

... More
Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet

150.8

-

-

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary,sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Cement Concrete Grade M-15 & M-20 - By Mechanical Means

42.08

-

-

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary,sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Prestressed / reinforced cement concrete grade M-20 & above - By Mechanical Means

289.58

-

-

... More
Dismantling kerb stone by manual means and disposal of dismantled material with all lifts and up to a lead of 1000 metre

495

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m

2143.44

-

-

... More
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.

104.92

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications RCC Grade M20 With Batching Plant, Transit Mixer and Concrete Pump

427.37

-

-

... More
Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications

44.59

-

-

... More
Wrought Iron and Mild Steel Welded Work Wrought iron and mild steel welded work (using angles, square bars, tees and channel grills, grating frames, gates and tree guards of any size and design etc. including cost of screens and welding rods or bolts and nuts complete fixed in position but without the cost of excavation and concrete for fixing which will be paid separately.

5.79

-

-

... More
Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses,bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone -III) : 3 graded stone aggregate 20 mm nominal size)

18.52

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

1046.59

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

5.04

-

-

... More
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching,refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

19.2

-

-

... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand)finished with a floating coat of neat cement and making necessary channels for the drain etc.complete.For pipes 100 to 250 mm diameter

32

-

-

... More
Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately :Rectangular manhole 120x90 cm with circular cover 560 mm dia of grade HD - 20

5

-

-

... More
Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap.

15

-

-

... More
Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete

100

-

-

... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.Ordinary soil - Mechanical Means - (Depth upto 3 m)

176.4

-

-

... More
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.

0.68

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.PCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump

136.96

-

-

... More
Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications

13.7

-

-

... More
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.Cable Duct Across the Road - Triple rRow for three utility services

46

-

-

... More
Providing of 7- Way 40mm Multi Ducts with solid permanently solidly lubricated Silicore in inner layer for ICT fibre cables comforming to ASTMF 2160, ASTM D 2444 and /or equivalent indian standard. External Sheath shall be in Orange Color and shall be free from visual defects like blisters, shrink holes, flaking,scratches, groove lines & surface roughness. The outer layer colour of the 7 nos. PLB HDPE ducts shall be Green, blue, yellow, Brown, violet, Grey , Red for differentiation, middle layer shall be transluscent and the inner layer shall be having permanently lubricated lining of Silicore . Outer sheath thickness shall be 1.2mm 0.2mm. The inner surface of the multi channel ducts shall be straight ribbed & shall be of a configuration for faster installation of cables. Wall thickness(mm) of each of the ducts Excluding rib height shall be 2.9mm 0.3mm. Seven couplers every 100 meter for duct jointing shall be provided. The coupler shall be used to join two HDPE pipes. It should either snap fit or Split type. The jointing shall meet the air pressure test of 15 Kg/cm2 for a minimum period of 2 hours. 14 End Plugs every 100 meters of pipe length shall be provided. End Plugs shall be used to seal the end of ducts so as to prevent any ingress of water/dirt etc. testing and commissioning. The rate is inclusive of required specials and fittings wherever necessary. ISO Requirements- ISO 9001, 14001, 18001 as per design drawing technical specifications and directions of Engineer in charge.

666

-

-

... More
Providing & laying in existing trench HDPE Power Duct of OD 160mm. It shall have three concentric layers viz. outer layer, middle layer and inner layer with ribs. The outer layer shall be made of HDPE material in red colour, middle layer shall be made of HDPE in translucent (natural) and the inner ribbed layer of solid permanent lubricant (PLB) i.e. Silicore.The inner surface of the multi channel ducts shall be straight ribbed & shall be of a configuration for faster installation of cables. 100% virgin HDPE raw material shall be used. No regrind shall be used and the duct shall be sourced from ISO 9001,14001,18001 and ISRS audited manufacturer only.One coupler every 12 meter for duct jointing shall be provided. The coupler shall be used to join two HDPE pipes. It should either snap fit or Split type.The jointing shall meet the air pressure test of 2 Kg/cm2 for a minimum period of 2 hours. 2 End Plugs every 50 meters of pipe length shall be provided. End Plugs shall be used to seal the end of ducts so as to prevent any ingress of water/dirt etc.The rate is inclusive of required specials and fittings wherever necessarylaying should be as per design drawing technical specifications and directions of Engineer in charge.

444

-

-

... More
Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete

1563.1

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

86.58

-

-

... More
Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

4

-

-

... More
Supplying and fixing SFRC Circular shape 560 mm dia precast R.C.C.manhole cover(Extra Heavy Duty) with frame - EHD - 35 to existing manhole cover slab including necessary fixing charges labour etc. complete

13

-

-

... More
Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres,stacking serviceable and unserviceable materials separately Bituminous course - By Mechanical Means

406.71

-

-

... More
Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres by Mechanical Means

2196

-

-

... More
Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Grading-I - Plant Mix Method

522.28

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

791.36

-

-

... More
Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.

2611.4

-

-

... More
Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.

9522

-

-

... More
Dense Graded Bituminous Macadam : - For grading - II (26.5 mm nominal size) Providing and laying dense graded bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (VG 30) @ 4.0 to 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.

294.44

-

-

... More
Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder(NRMB) @ 5.2 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No.507 complete in all respects For Grading - I ( 19 mm nominal size )

190.44

-

-

... More
Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately.

10

-

-

... More
Construction of median and Island above road level with approved material brought from borrow pits,spread, sloped and compacted as per clause 408

196.95

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications RCC Grade M20 With Batching Plant, Transit Mixer and Concrete Pump

7.5

-

-

... More
Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications

0.53

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

172.81

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations,footings, bases for columns

123.4

-

-

... More
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Medium shade pigment 50% white cement, 50 % ordinary cement

1510.2

-

-

... More
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

1670.4

-

-

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

160.2

-

-

... More
Supplying and fixing of MS Powder Coated chain in between bollards including fixing in position etc.complete.

534

-

-

... More
Providing and fixing MS Powder Coated, 750mm height, 100mm dia, thickness 3mm bollards as per drawing including fixing with a MS base plate of size 150x150x6mm.Edge shall be smoothened as directed by Engineer in charge. All MS components are in MS Powder Coated finish, made using modern, automatic machines like CNC machine, robotic welding, laser cutting, water jets etc. The rate shall includes cost and conveyance of all materials, base plate ,screws ,bolts , fabrication, transportation,cutting and making good the floors, loading and unloading, handling of machineries all electrical charges etc. labor charges, lead, lift etc. complete as directed by Engineer-in-Charge.

534

-

-

... More
Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)

444

-

-

... More
Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)

444

-

-

... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.60 cm equilateral triangle

3

-

-

... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.60 cm circular

1

-

-

... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.60 cm x 45 cm rectangular

1

-

-

... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.60 cm x 60 cm square

1

-

-

... More
Providing and fixing of direction and place identification retro-reflectorised sign with 7 years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with area not exceeding 0.9 sqm,with suitable back supporting frame of MS angle 40x40x6 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.

4.32

-

-

... More
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC Using Concrete Mixer on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409

796

-

-

... More
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces

378.2

-

-

... More
Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control Over 10 cm in width

10.64

-

-

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

166.5

-

-

... More
Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector

222

-

-

... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.Ordinary soil - Mechanical Means - (Depth upto 3 m)

24341.53

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications PCC Grade M15 ( Without formwork)

339

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.RCC Grade M30 - Using Batching Plant, Transit Mixer and Concrete Pump

5270.61

-

-

... More
Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications

439.82

-

-

... More
Providing and construction of a gabian structure for retaining earth with segments of wire crates of size 7 m x 3 m x 0.6 m each divided into 1.5 m compartments by cross netting, made from 4 mm galvanised steel wire @ 32 kg per 10 sqm having minimum tensile strength of 300 Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven into mesh with double twist, mesh size not exceeding100 x 100 mm, filled with boulders with least dimension of 200 mm, all loose ends to be tied with 4 mm galvanised steel wire

2668.5

-

-

... More
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water,uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.

513.68

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

277.84

-

-

... More
Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment).

167.73

-

-

... More
Rough dressing the trenched ground including breaking clods.

513.68

-

-

... More
Fine dressing of the ground

513.68

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-incharge (cost of sludge, dump manure and/ or good earth to be paid separately).

503.54

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-incharge

503.54

-

-

... More
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).

503.54

-

-

... More
Flooding the ground with water including making kiaries and dismantling the same

939.68

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

56.08

-

-

... More
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.

513.68

-

-

... More
Providing & laying Buffalo grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, with sprinkler and maintenance for 30 days or more till the grass established properly as per direction of officer in charge.

939.68

-

-

... More
Providing and displaying Vinca different colour 6 to 8 well developed branch in full bloom stacked with green painted Bamboo stick in 25 cm Earthen Pot/Plastic Pot on already developed flowering bed as per the direction of Engineer in Charge

200

-

-

... More
Supply and stacking of plant Portulaca hybrid

200

-

-

... More
Providing and displaying Ixora coccinia well developed with fresh and healthy bushy plant in full bloom 60cm height on already developed flowering bed as per the direction of Engineer in Charge

200

-

-

... More
Providing and watering of irrigation water through water tanker of Horticulture features i.e.tree,shrubs, hedge/edge, ground cover etc. at the site of work. Water tanker having 5000 lit.capacity with one labour for watering i/c cost of water, filling of tanker, watering at site with all leads and lifts as per direction of officer-in-charge.Cost of 5000 Ltrs for Each Trip

24

-

-

... More
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

1147.18

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C.kerb stone shall be approved by Engineer-in-Charge)

8.83

-

-

... More
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

41.26

-

-

... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

316.94

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

316.94

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

316.94

-

-

... More
Providing and fixing Cast iron railings, grills or gate with required MS section made of Hollow tubes,channels, plates etc. as per design, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary steel nuts and bolts complete, i/c fixing the railing with necessary accessories & dash fasteners, bolts etc., of required size as per the drawing and as per the approval of Engineer-in-charge.

1764.92

-

-

... More
Providing Z steel sheet pile of size 400x185x10mm driving down vertically in lines and levels interlocking with adjacent piles with suitable pile driving unit and all accessories including all labour hire charges etc.complete and as per the directions of departmental officers at site.

2866.97

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C

133

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

139

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire

1770

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

830

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm

324

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

270

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm

50

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch

44

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

54

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

44

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess,including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch,connection etc. as required. (For light plugs to be used in non residentialbuildings).

1

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

39

-

-

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.

163

-

-

... More
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess,including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

63

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 6way, Double door

54

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

166

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

21

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

61

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

59

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

3

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

9

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

59

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

2

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

8

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 6 way, Double door SPN MCBDB

54

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB

2

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

6

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

9

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

2

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP42/43)

1

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP42/43)

8

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.00 mm copper conductor ( 14 SWG)

1340

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)

170

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor ( 8 SWG)

350

-

-

... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

600

-

-

... More
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3mm copper strip

20

-

-

... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)

132

-

-

... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

20

-

-

... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

36

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required.

4

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode,including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

50

-

-

... More
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 70 sq mm

12

-

-

... More
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm

12

-

-

... More
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 6 sq mm

12

-

-

... More
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm

12

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp

2770

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp

625

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

90

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm

20

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

55

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp

200

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp

300

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

100

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

108

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

6

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

14

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed I XLPE aluminium conductor cable of 1.1 kV grade as required.4 X 6 sq.mm

12

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 kV grade as required.4 X 4 sq.mm

16

-

-

... More
Supply and Installation of LED Recessed step fitting with aluminium die cast housing with powder coated wire guard. IP65 or higher rated CRI70, colour temperature-3000K, , 50000 burning hours as per L70 Criteria, complaint to photo biological safety std IEC62471 Ambient temp-0 to 45DegC, Driver efficiency75%, THD15%, Powerfactor0.95, Surge protection in CM-4 KV, Constant Voltage Operated driver with range 110-320V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.wattage upto 5W LED Step light luminaire delivering 60 lm, similar to WIPRO make LT51-370-XXX-30- XX OR Equivalent in Philips/Jaquar

66

-

-

... More
Supply and installation of IP65 rated LED Bulkhead fitting with aluminium diecast housing with powder coated ,Polycarbonate opal diffuser,High quality silicon gasket for IP65 Protection,Ambient temp-0 to 45 DegC,LED with 50000 burning hours as per L70 Criteria, CRI70, color temperature- 5700K, , Complete assembly with LED, Driver and accessories pre wired up to terminal block Driver With efficiency85%,THD10%, Power factor0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard. 10W LED Bulkhead luminaire delivering 720lm, similar to WIPRO make : LW07-141-XXX- 57-G1 or equivalent in Philips/ Jaquar.

40

-

-

... More
Supply and Installation of 10W LED integral Up-down light with not less than 670 lumens and CCT of 3000k CRI80, IP65 with aluminium housing with anthracite color suitable for aesthetics with PF 0.9 & longer life. Similar to Philips make "31450 Propulsio" or equivalent in Wipro/ Jaquar

6

-

-

... More
Supply and installation of high performance batten for dusty and humid environment with polycarbonate housing ,CCT : 6500 and 50000 burning hours as per L70@B50 and efficacy 120 Lm/W.The luminare should be flicker free with ripple factor 5% ,CRI 80, PF 0.95 and IP 65, IK 08.The luminaire shall have 3Kv surge protection with high cut off voltage of 300 and THD 10 Similar to JAQUAR make :LRPD01X020XWor equivalent in Wipro/ Philips.

82

-

-

... More
Supply and installation of high performance batten for dusty and humid environment with poly carbonate housing ,CCT : 6500 and 50000 burning hours as per L70@B50 and efficacy 120 Lm/W. Having a maximum wattage upto 40W.The luminare should be flicker free with ripple factor 5% ,CRI 80, PF0.95 and IP 65, IK 08.The luminaire shall have 4 Kv surge protection with high cut off voltage of 325 and THD 10 Similar to JAQUAR make : LPRD01X040XW or equivalent in Wipro/philips

81

-

-

... More
Supply and installation of heavy duty escalator having a capacity of 6000 people per hour & a min speed of 30 meter per min. The escalator must have 6750 mm rise ,angle of inclination is 30 degree and having 1010 mm width between skirt panels.The balustrade made up of min 8mm thick tempered glass panel.The deck board and skirt guard made up of hairline finished stainless steel,moving handrail made up of synthetic rubber.The steps made up of one piece stainless steel , steps in black with yellow demarcation lines on all 3 sides.The escalator must have features like Fault operation panel,Autostart/ stop with traffic flow lights.The operating panel must have emergency stop button, buzzer and stop switch, and up and down start switch.The power supply for traction -415 V ,3 phase 50 Hz,with voltage variationof +/- 5 to 10%. The escalator must have all the operational and safety features such as operational break,non reversal device, handrail entry device,broken step chain device,comb plate safety device on both landings,main circuit breaker on upper landing,step chain roller monitoring switch,sockets for manual inspections,manual inspection control device,over speed governor, broken step and chain wheel control contact at both landings,main drive chain contact,ground contact etc. as mentioned by latest IS standards.

3

-

-

... More
Supply installation testing and commissioning of Passenger lift having a capacity of 13 passengers,minimum rated load of 884 kg. The minimum net inside car area is 2.06sq.m and maximum net inside car area should be 2.20 sq.m . The lift must have a minimum speed of 1 mps and 2 stops. The lift car must be of anti-vandal SS finishes, SS 304/better life grade steel shall be used for all steel parts like Handrail, Landing (Faceplate, Frame, Buttons). The Interior shall be with Half size mirror, beige interior shades or similar shade as approved, Granite flooring with approved shade, Braille enabled on push buttons with LCD display inside Car panels and White Dot Matrix / equivalent in landing panels.The lift must have the standard features like anti nuisance car call protection, over load device, emergency car light unit, emergency alarm button, infrared curtain door protection,door time protection,automatic operation for car fan, Provision for music system wiring (in travelling cable) Voice announcement unit,Overload function with audio-visual indication in car operating panel, Fire man switch with Fireman operation,full door Infra-red screen for car door. The lift and its installation shall conform to relevant IS standards.

5

-

-

... More
Supply installation testing and commissioning of unitised substation (outdoor type) having 160KVA,11KV/433V, 3 phase, outdoor type, vector DYN-11 transformer with off circuit tappings from +5% to -10% in steps of 2.5%, changeable on off circuit by tap links provided, with WTI & LV side cable box suitable for Provision for MCCB and HV terminals connected to 11 KV, 26.3 KA, 630 A Load Break Switch, with incoming suitable for XLPE cable, with HT HRC fuses, 3 Nos CTs, 1 No PT, provision for fixing TOD Meter and output connected to 11KV seal off bushings to the transformer.

1

-

-

... More
Supply Installation, testing and commissioning of 100 KW/125 KVA Diesel generator set with CPCBII approved acoustic enclosure comprising of radiator Cooled Diesel engine 1500 RPM, complete with standard accessories. Coupled to alternator with rated at 125 KVA at 415 Volts mounted on Channel Iron Base Frame complete with Manual Control System with Fuel Tank ,Batteries and battery charger. The generator control panel with necessary breakers, ammeters, voltmeter,energy meter,relays,and other accessories as per the Electrical inspectorate standards.must be provided.

1

-

-

... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted,front operated panel board made out of 16 SWG / 1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall confirm IS 8623 standards.INCOMER:100A TPN Isolator - 1 no OUTGOINGS: 63A ,25KA,TP MCCB - 5 nos

1

-

-

... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted,front operated panel board made out of 16 SWG / 1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board,heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall confirm IS 8623 standards.INCOMER:100A TPN Isolator - 1 no OUTGOINGS:63A ,25KA,TP MCCB - 7 nos

1

-

-

... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted,front operated panel board made out of 16 SWG / 1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board,heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall confirm IS 8623 standards.INCOMER: 63A TPN Isolator - 1 no OUTGOINGS:32A ,10 KA,DP MCB -10 nos 32A, HRC FUSE - 10 nos

1

-

-

... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted,front operated panel board made out of 16 SWG / 1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board,heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall confirm IS 8623 standards.INCOMER: 63A TPN Isolator - 1 no OUTGOINGS:32A ,10 KA,DP MCB -11 nos 32A, HRC FUSE - 11 nos

4

-

-

... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted,front operated panel board made out of 16 SWG / 1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board,heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall confirm IS 8623 standards.INCOMER:250A,35KA, 4P MCCB with 3OC & 1 E/F - 1 no 200A,35KA, 4P MCCB with 3OC &1E/F - 1 no 250A 4P CONTACTOR- 1 no 200A 4P CONTACTOR- 1 no AMF relay with interlock- 1 no 51G relay- 1 no OUTGOINGS:125A ,25KA, TP,MCCB - 4 nos 63A , 25KA, TP, MCCB - 2 nos 160A TPN Isolator - 1 nos

1

-

-

... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted,front operated panel board made out of 16 SWG / 1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board,heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall confirm IS 8623 standards INCOMER: 63A TPN ISOLATOR OUTGOINGS:32A TP MCB- 4 Nos Automatic Star delta starter- 4 Nos.12A TP Power AC3 Duty contactor - 4 nos.

1

-

-

... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted,front operated panel board made out of 16 SWG / 1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board,heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall confirm IS 8623 standards INCOMER 100A,25KA,MCCB - 1 No OUTGOINGS:16A TP MCB-4nos 10A TP MCB - 4 nos 32A TP MCB- 4nos DOL Starter - 12 nos 12A TP Power AC3 Duty contactor- 4nos 9A TP Power AC3 Duty contactor- 8nos

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee”(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.(900 mm width X 62.5 mm depth X 2.0 mm thickness)

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.(450 mm width X 62.5 mm depth X 2.0 mm thickness)

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee”(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.(300 mm width X 62.5 mm depth X 2.0 mm thickness)

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends”(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.(900 mm width X 62.5 mm depth X 2.0 mm thickness)

6

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends”(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.(450 mm width X 62.5 mm depth X 2.0 mm thickness)

2

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends”(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.(300 mm width X 62.5 mm depth X 2.0 mm thickness)

4

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(900 mm width X 62.5 mm depth X 2.0 mm thickness)

50

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(450 mm width X 62.5 mm depth X 2.0 mm thickness)

70

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(300 mm width X 62.5 mm depth X 2.0 mm thickness)

160

-

-

... More
Supply and installation of three phase centrifugal mono bloc pump of capacity 10 HP having a protection class of IP 44, dimension 100 X 100 mm , with CI impeller , CI delivery casing, CI motor bodyand gland packed. Having a rated speed of 3000 rpm. Suction lift up to 7.5 m . Head up to 20m . Designed to prevent overloading and motor burning. also having automatic air release during priming.

2

-

-

... More
FIRE FIGHTING AND FIRE ALARM WORKS

-

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm @ 45 m

2

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism,12 /24 volts electric starting equipment,diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated,common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.2280 lpm @ 45 m

1

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS :325.M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.180 lpm @ 55 m

2

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

1

-

-

... More
Supply & installation of Glycerin filled Pressure Gauge with 0-200 psi range, 3/8' BSP bottom entry 100 MM dial weather proof with SS internals and isolation cock.

8

-

-

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required

5

-

-

... More
Fabrication, supplying, Installation, Testing and Commissioning of electrical control panel of cubicle construction (Motor Control Centre Type), floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection, having switchgears and accessories mounting and internal wiring, two earth bars of 25 x 3 mm copper strip connecting all sections, two earth terminals, numbering etc.complete in all respect, suitable for operation on 415 V,phase, Hz, AC supply with enclosure protection class IP 42 as required and as per detailed specifications as follows. INCOMER 200 A , 4P ISOLATOR -1 no 200 A continuous duty,415Volts A/C, 3 phase and neutral Aluminium busbar with colour coded heat shrink sleeves supported on SMC type grip supports 35kA.RYB phase indicating lamps (lamps shall be of LED) with control fuses/MCB 2A - 3 sets.Single phase digital ammeters with range 0-200A - 3 nos.CTs - ratio 200/5A 15VA CL-1 - 3 nos.Voltmeter selector switch with three phase digital voltmeter range (0-500) V complete with fuses - 1 no.OUT GOINGS (a) Main fire pump 125A TPN isolator with adjustable settings - 2 No Fully automatic star delta starter without portection, suitable for 40HP fire fighting motor application complete with all necessary accessories as required.- 2nos MAKE : L & T / DANFOSS / SIEMENS(b) Jockey pump 32A TPN ISOLATOR with adjustable settings - 2 Nos 10kW Star delta Starter suitable for fire fighting motor application complete with all necessary accessories as required -2No MAKE : L & T /SIEMENS / SCHNIEDER (c) Diesel Engine Control (i) Auto/Manual selector switch & 3 attempt starting device, timers and relays as required,push buttons, start/stop in manual mode.(ii) Indicating lamp for High/Low lub. Oil pressure, High water temperature and Engine ON indication.(iii)Battery charger suitable for 12V/24V DC with boost and trickle selector switch, 0-30V DC volt meter, 0-20A DC ammeter.(iv) All standard relays and acessories for automatic operation of diesel engine.(v)All accessories required for lock out and other functions as per the specifications.Supply, Installation,Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump,Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification All complete as above

1

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.150 mm dia

341

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia

17

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia

11

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia

242

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia

72

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia

37

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm dia

39

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia

52

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :40 mm dia

39

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 32 mm dia

105

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia

362

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150 MM

10

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 MM

3

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :80 MM

5

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :50 MM

8

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :200 mm dia

2

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia

4

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia

3

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm dia

3

-

-

... More
Supply, installation, testing and commissioning of Air Release Valve Gun metal body Horizontal Lift Type Having Screwed ends as per ISO Mark of following size as required:25 mm

6

-

-

... More
Supply, installation, testing and commissioning of stainless steel Ball Valves with necessary fittings confirming IS0 17292 of following sizes as required.25mm dia

29

-

-

... More
Supply, installation, testing and commissioning of stainless steel Ball Valves with necessary fittings confirming IS0 17292 of following sizes as required.50mm dia

3

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent type Sprinkler

155

-

-

... More
Supplying and fixing 4 way FBCH ( Fire Brigade Collective Head) of gun metal body with 4 nos. gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for 100 mm dia M.S. pipe connection, conforming to IS 904 as required.

1

-

-

... More
Supplying and fixing 4 Way FBI ( Fire Brigade Inlet ) of gun metal body with 4 Nos. stainless steel male instantaneous inlet couplings complete with cap and chain as required. For 100 mm dia M.S. Pipe connection conforming to IS :904 as required.

1

-

-

... More
Supplying and fixing single headed internal/external hydrant valve with instantaneous Gun metal couplings of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (type a) with blank Gunmetal cap and chain with necessary orifice plate, M.S/ GI tee tapping from the wet riser, distant piece & any other accessories as required.

9

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel

9

-

-

... More
Supplying and fixing 63 mm dia 15 mtr long CP hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc conforming to IS 636 (type-A) as required.

18

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.

3

-

-

... More
Supply & installation of Hose Cabinets to accommodate two piece of hose pipe along with two pair of male and female coupling and one branch pipe. The double door cabinet is made up of FRP sheet with glass fronted hinged doors and lock, painted with Post Office red colour.

9

-

-

... More
Supply and installation of dry chemical powder type ABC 5Kg Stored Pressure Fire Extinguisher complete with initial charges, discharge hose, wall mounting brackets etc. and with ISI mark.

14

-

-

... More
Supplying and fixing of carbon dioxide (CO2 type) fire extinguisher made up of aluminium alloy with cylinder fully charged 4.5kg capacity marked with relevant ISI mark.

8

-

-

... More
Supply, installation, testing and commissioning of Addressable fire alarm Panel 1 loop. 230Vac, 4 sounder circuits, 4 line display and networking capability. 6 Amp PSU with 460mA loop capability with two 12v battery for 24 Hr backup with UL listed & FM approved. The Panel Shall have on board TCP/IP Lan port to facilate remote operation of the panel.MAKE : SEIMENS / NOTIFIER

1

-

-

... More
Supply and fixing of Manual Call Point and giving connections as required.

8

-

-

... More
Supply, installation, testing, and commissioning of Photoelectric smoke detectors with base in the proposed location complete with all accessories

93

-

-

... More
Supply, installation, testing and commissioning of Response Indicators

3

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required

3

-

-

... More
Supply, drawing, testing and commissioning of 2Cx1.5 Sq MM Red coloured PVC sheathed firerated, armoured Copper conductor cables are laying Surface/recessed in the wall and ceiling with ISI mark.

1210

-

-

... More
Supply and fixing of strobe cum hooters with relay module and giving connections as required

6

-

-

... More
Supply and installation of LED Exit / Egress Edgelit lights with a rechargeable battery, conform to IS 9457 :2005, 22 SWG CRCA white powder-coated housing having input voltage of 230V 50Hz in the proposed locations and giving connections as required.MAKE :PROLITE / CEASEFIRE

5

-

-

... More
Supply and fixing in position photo luminescent type signages with indication arrows and letters for Fire hose/Fire Fighting Equipment /Fire Extinguisher.

9

-

-

... More
Supply and fixing in position exit signages photoluminscent type with indication arrows and letters EXIT / FIRE EXIT.(Make:PROLITE / CEASEFIRE)

8

-

-

... More
HVAC SYSTEM

-

-

-

... More
Supply and installation of Axial flow fan with aluminium air flow blade, TEFC motor (For Supply and exhuast)Air flow - 2000/2500 CFM @ 20mm static

4

-

-

... More
Supply and installation of Axial flow fan with aluminium air flow blade, TEFC motor (For Supply and exhuast)Air flow - 5500 CFM @ 40mm static

4

-

-

... More
Supply and installation of axial flow fan (smoke extract system) with class H motor with Airflow 13000 CFM@ 40mm static.

4

-

-

... More
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

300

-

-

... More
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

350

-

-

... More
Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

5

-

-

... More
Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

5

-

-

... More
OPERATION AND MAINTENANCE

-

-

-

... More
Maintenance Charges for 1st year

1

-

-

... More
Maintenance Charges for 2nd year

1

-

-

... More
Maintenance Charges for 3rd year

1

-

-

... More
Maintenance Charges for 4th year

1

-

-

... More
Maintenance Charges for 5th year

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.