Public Works Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Oct 2024
Closing Date15 Oct 2024
Tender Amount₹ 1,69,427
Costs
EMD
₹ 4,236Document Cost
₹ 555Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_695276_1Bid Award Id
ViewTender No
ESDT/ET_95/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://www.keralapwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
6
13218
2203.15
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
6
1139
189.85
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
6
265
44.22
90.10.3.24:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )Step Fan regulator - type 2 M
6
1327
221.22
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
8
2675
334.39
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
8
1865
233.17
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
12
1217
101.45
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
18
2374
131.94
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1
588
588.56
OD135936/2024-2025:Supply Installation Testing and commissioning of 2KVA/1.8KW, 0.9 output power factor model Single phase Input and single phase output type True online double-conversion topology and zero transfer time pure sine wave ups system with salient features like, maximum power availability Leading AC-AC efficiency up to 95% . Low harmonic pollution(iTHD<2%) & high input power factor (>0.99) , Voltage regulation+- 1%, DSP based technology , IGBT Rectifier and inverter, Generator compatable, Noise level 50dBA @ 1 meter. Display Panel (In-build LC Display & LED ) Input: Voltage / Frequency Bypass: Voltage / Frequency, Temperature: STS/Inverter/PFC, Battery: Voltage / Capacity Output: Voltage / frequency / Current, Event Logging & Statistical Data (On LCD): UPS should capture and display up to 500 events, User Programmable Parameters & Settings (On LCD), Indications (LED), Audible Alarms for Mains Failure / Battery Low Alarm / UPS Overload / Fault / Shut down etc. The UPS shall be housed in a free standing enclosure, and free from defects, sharp edges, nicks, scratches, burs etc. and provisions for suitable ventilation, easy maintenance, etc. (Delta or equivalent) providing suitable stand for UPS and Battery.The supplier should be submitting Tested documents, Operation manual, service manual etc. EXTRNAL EXIDE / HBL MAKE SMF BATTERY 12V, 42AH, 6 NUMBERS FOR THE BACKUP 60 MINUTES AND MORE FOR 2KVA FULL LOAD. Suitable Battery Rack,suitable ups stand, Battery Breaker Switch with Cables and its accessories. Warranty for 3 years for UPS and battery from the date of invoice.
1
79290
79290.21
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
60
3853
64.22
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
20
2377
118.86
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
11
981
89.27
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
10
1389
138.91
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
59
5857
99.28
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
1
2092
2092.26
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
4
948
237.11
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
804
402.47
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1
2290
2290.97
OD135939/2024-2025:Supplying and fixing DP sheet steel enclosure on surface/ recess on wall and etc. as required.
1
424
424.25
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements