Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date8 Oct 2024
Closing Date5 Nov 2024
Tender Amount₹ 35,40,000
Costs
EMD
₹ 70,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_678434_1Bid Award Id
ViewTender No
8515Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per item no 3 above but as in skirting/ dados, set and jointed in neat cement slurry and pointed in white or coloured cement to match , over 10 mm thick rendering in CM 1;4 etc complete alll as spd & directed.
6
-
-
M & L for false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of size 595x595mm of approved texture , design and patterns, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanised@ 120 grams per sqm including both sides) comprising of main T runners of size 24x38mm of length 3000mm , cross T of size 24x32mm length 1200mm and seccondary intermediate cross T of size 24x32mm of length 600mm to form grid moduled of size 600x600mm, suspended from ceiling usig galvanised mild steel items(galvanizing @ 80 grams per Sqm) ie, 12x50mm long dash fasteners,6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x16mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with galvanized iron perimeter wall angle or size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall SS screws with 15mm thick tegular,butt edged without perforation plain/designer light weight calcium silicate anti-microbial bio-safe coated false ceiling tiles conforming to JIS Z 2801 and ASTM G 21 complete all as specified and directed
22
-
-
M & L for 5mm thick WPC wall paneling colour WPC sheet inclusive of solvent cement and fixing at site including framework complete all as specified and directed.
25
-
-
Taking down chowkats with shutter any description (without taking off shutters from the frame) area n exc. 1.5 Sq.m each.complete all as specified and directed.
2
-
-
Taking down chowkats with shutter any description (without taking off shutters from the frame) area exc. 1.5 Sq.m but not exc. 4 Sq.m each complete all as specified and directed..
1
-
-
M&L Aluminium anodised powder coated frame for door/ window with one or more rebates including jointing cleat for fixing and similar frame work etc complete all as specified and directed.
10
-
-
M & L Aluminium anodised powder coated for door shutter side hung without sash bar aluminium section 0.55 kg/m includng necessary jointing, glazed clip joint cleats, rubber gaskets, including aluminium fittings dead lock 4 levers, two numbers of aluminium alloy anodised tower bolts , hinges, handles etc. includinjg fixing frame to wall members with rawl plugs complete. all as spd & directed by Engr in Charge.
2
-
-
M & L Aluminium anodised powder coated for windows shutter side hung without sash bar aluminium section 0.55 kg/m includng necessary jointing, glazed clip joint cleats, rubber gaskets, including aluminium fittings , two numbers of aluminium alloy anodised tower bolts , hinges, handles etc. includinjg fixing frame to wall members with rawl plugs complete. all as spd & directed by Engr in Charge.
3
-
-
M&L for 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in door shutter complete all as specified
1
-
-
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick
aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixedcomplete as specified and directed by Engr in charge.
1
-
-
S & F sheet glass ordinary quality 4 mm thick and glazing with oil putty /glazing clips of any description complete all as spd & directed.
3
-
-
M&L for preparation of old treated surfaces of walls and applying two coat of oil bound distemper complete all as specified and directed.
560
-
-
M & L for prepration of old wall surfaces and applying one coat of weather proof coat paint ( Antifungal paint) over a coat of primer wherever fungal growth are noticed on external wall surface complete all as specified.
970
-
-
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying UG cable and water supply pipeline excavation not exc 1.5m in depth and getting out in soft loose soil all as specified and as directed.
343
-
-
Returning and refilling of excavated soil up to a depth of 30 cm after riddling the excavated soil for Cushioning of cable and refilling of trench with normal excavated soil all as specified and directed :-
287
-
-
Removing excavated material not exc 50m and depositing where as directed at a level not exc 1.5m above the starting point all as specified and as directed
56
-
-
Supply and lay in trenches burnt bricks sub-class ‘B’ size designation 75 for cable protection all as specified and as directed.
3.98
-
-
Supply and laying only in trenches or passing through pipes/ poles etc LT XLPE cable heavy duty 1100 Volts grade 16 Sqmm 4 core with aluminium conductor of the following connections with provn of cable lugs and glands as required of following sizes.
300
-
-
Supply and laying only in trenches or passing through pipes/ poles etc LT XLPE cable heavy duty 1100 Volts grade 10 Sqmm 2 core with aluminium conductor of the following connections with provn of cable lugs and glands as required of following sizes.
200
-
-
Supply and fixing LED street light fitting 100Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
26
-
-
S & F New High Power LED flood light fitting to ensure uniform distribution with die cast aluminium IP 66 flood light of capacity 150W LED fittings with suitable fixing accessories all as specified and as directed. Make : Wipro/ Philips/ Havells/Crompton
28
-
-
Supply and fixing Cable Junction box made out of polycarbonate material IP66 with metric knockouts for cable entry for 10-16 Sq mm cable size 155x210x92mm including 1 No MCB 10 Amps with DIN bar and 4 Nos FRP insulators and fixing the box to street light pole made of 25x 3mm flat iron with clamps, nuts and bolts complete as per Cat No.DK 1616G of Hensel or equivalent make all as specified and directed by Engineer-in-charge
4
-
-
S & F astronomical and digital time switch suitable for operation on 230 Volts AC complete all as specified and directed. Make : Havells/L&T or equivalant
1
-
-
S&F PVC copper cable, 3 core, multi stranded of size 2.5 Sqmm in and including PVC rigid conduit of size 20mm medium grade with all accessories as per site requirement fixed on pole with GI plate of size 20x3mm and GI nut,bolt and washer etc, all as specified and directed.
235
-
-
M&L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation with four foundation bolt embedded in the PCC for fixing of GI street light pole of 8 mtr height, with GI nut and washer of suitable size including finishing to exposed concrete surfaces even and fair and provision of necessary form work for rough finished surfaces complete all as specified.
30
-
-
M&L for Plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregates as in coping including finishing to exposed concrete surfaces even and fair and provision of necessary form work for rough finished surfaces complete all as specified and directed.
1.6
-
-
Supply and installation of steel tubular pole with Polygonal/Octagonal GI pole, hot dip galvanised (thickness of galvanisation not less than 65 microns), thickness of sheet not less than 3mm, thickness of base plate not less than 16mm, pole bottom dia 130mm and top dia 70mm with four GI foundation bolts of suitable length and dia, GI bracket at top suitable to fix six numbers of 150watt flood light fittings with GI nut bolts and washers etc, length of pole 8 metres all as specified and directed. (Note :- Excavation,earth work & PCC etc shall be measured and paid seperately under relevent item) Make- Crompton/Bajaj or equivalent.
5
-
-
M&L Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom,class 10 all as specified and directed.
26
-
-
M&L for Fabrication and fixing of street light bracket made of 40 mm dia GI tubing light grade, 1.2 metre long, bent to shape fixed to pole with 50mm x 6mm Flat iron clamps with nuts and bolts including painting two coats of aluminium paint over a coat of zinc chrome primer all as directed.
26
-
-
Taking down old unserviceable GI Pipe with fittings laid in trenches/floor/on wall/roof complete of following sizes and kept at site all as specified and directed.
-
-
-
(a) 25 mm dia
300
-
-
(b) 40 mm dia
300
-
-
(c) 50 mm dia
100
-
-
(d) 63 mm dia
150
-
-
(e) 80 mm dia
100
-
-
(f) 100mm dia
50
-
-
Supply and fixing, laying & testing UPVC pipes (ASTM D-1785 Schedule 40)of following capacities, ISI marked pressure rating 15 to 42 Kg/Sqcm and confiming to IS 4986 including all fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches/floor /wall complete all as specified and directed.
-
-
-
Ditto 25 mm dia
300
-
-
Ditto 40 mm dia
300
-
-
Ditto-50 mm dia
100
-
-
Ditto- 65 mm dia
150
-
-
Ditto-80 mm dia
100
-
-
Ditto- 100mm dia
50
-
-
Repairing of existing valve chamber of size by dismantling the existing chamber of size 900mmx900mmx900mm internal size including necessary earth work,excavation, PCC 1:4:8 type D2 for foundation, brick work in cement mortar 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 4mm thick on 40x40x6mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as specified and as shown on drawings.
10
-
-
Supply and fix in repairs CI Ball Foot Valve Heavy duty of CI body and cover with Nitrile Rubber coated ball with Covering ring one side flanged complete of 80mm dia size all as specified and directed.
2
-
-
Supply and fix in repairs CI Ball Foot Valve Heavy duty of CI body and cover with Nitrile Rubber coated ball with Covering ring one side flanged complete of 50mm dia size all as specified and directed.
2
-
-
M&L for Construction of valve chamber of size 900mmx900mmx900mm internal size including necessary earth work,excavation, PCC 1:4:8 type D2 for foundation, brick work in cement mortar 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 4mm thick on 40x40x6mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as specified and as shown on drawings.
1
-
-
All as per item No.50 here-in-before but of internal size 600mmx600mmx750mm.
3
-
-
Supply and fix in repair Gun metal globe or gate valve of 25 mm dia sizes with iron wheel head screwed both ends conforming to IS 778 of 84 for iron pipe complete all as specified and directed. Make- Zoloto/Bir/Prakash.
20
-
-
Ditto- 40 mm dia
20
-
-
Ditto- 50 mm dia
8
-
-
Supply and fix in repair CI Sluice valve of following sizes flanged, heavy duty, class PN 1.6, as per IS-14856 including brass spindle, with hand wheel, nuts bolts and gaskets complete all as specified and directed, Make- Zoloto/Bir/Kirloskar/RMCO.
-
-
-
ditto- 80 mm dia
2
-
-
ditto-100 mm dia
2
-
-
Supply and fix in repair cast Iron butterfly valve confirmimg to IS: 13095 operating with lever suitable for 80mm GI pipe all as specified and directed.
1
-
-
Supply and fix in repair cast Iron butterfly valve confirmimg to IS: 13095 operating with lever suitable for 63mm GI pipe all as specified and directed. Make- Zoloto/Bir/Kirloskar/RMCO.
1
-
-
Supply and fix in repair 100 mm Non return Sluice valve flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindle with nut, long body, class P N 1.6, conforming to IS 14846 of 2000 including all flange joint with rubber or fiber board, bolts, nuts and washers complete all as specified and directed by Eng-in-Charge.
2
-
-
Supply and fix in repair 80 mm Non return Sluice valve flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindle with nut, long body, class P N 1.6, conforming to IS 14846 of 2000 including all flange joint with rubber or fiber board, bolts, nuts and washers complete all as specified and directed by Eng-in-Charge.
2
-
-
Supply and fix Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm
3
-
-
Supply, fix, install and testing of Chlorine dozing pump of maximum flow rate 12ltr/hour and maximum injection pressure 2 kg/Sq.cm, speed adjustment 0 to 100 strokes per minute,40watt worked on 230V AC single phase complete all as specified and directed. Make- RMCO/equivalent
3
-
-
Material and labour for replacement of maintenance free chemical earthing with specifications as follows:-
6
-
-
(a) Excavation and earth work for not less than 0.60x0.60m size hole at a depth of 3 mtr in any type of soil all as directed and specified.
-
-
-
(b) Nickal sealed Copper bonded rod of 17.2mm dia x 3 mtr long x 250 microns encapsulated conductive concrete 100mm outer dia with vertical strip of ISI marked ,IEC 62561-2:2018 certified.
-
-
-
(c) Fixing of Nickel sealed copper bonded strip 25mm x 3mm x 100 Microns (Length not exceeding 7.5 M). Fixing of copper earth electrode by exothermic welding/M8SS 304 grade Nut & Bolt all as directed.
-
-
-
(d) Mixture of Excel electra fill compound of IEC 62561-7:2018 certified, RoHS & TCLP Tested & Certified and soil with fine granule capable of moisture content should make it in a tighty slurry form by adding water and fill it up from the bottom portion.(Appx 50Kg) (dia around the earth rod for chemical filling is 300mm)
-
-
-
(e) Mixture of Excel electra fill compound highly conductive carbon based RoHS & TCLP, tested and certified, and soil with fine granule capable of moisture content should make it in a tight slurry form by adding water and fill it above the previous mixture all as specified.(Appx 30Kg) (dia around the earth rod for chemical filling is 300mm)
-
-
-
(f) Add gravel at the top of the portion for easy passage of water and removal of air bubbles at the time of filling of electra fill plus and electra fill compound is necessary for easy dissipation of fault current.
-
-
-
(g) Fixing of PVC earth pit chamber of size 24 x 24cm with M8 SS 304 grade nut and bolts all as specified.
-
-
-
(h) FRP earthing display board 254 x 380mm made out of plasic material showing information related to type of earthing, earthing result, due date of testing along with fixing size 610mm height made of plastic hollow pipe of 20mm dia.
-
-
-
Make : Excelearthings or equivalent, Make of chemical : Excel electrafil or equivalent
-
-
-
Note (i) Rate of excavation and earth work shall deemed to be included in the item rate. (ii) Testing of earthing after completion of work and the result of each earth should not be more than 1 Ohm. (ii) All the joints except at test point shall be done with exothermic welding. (iii) Earth tester for testing the ER value of earth pits shall be provided by the contractor. (iv) Suitable soil with fine granule capable for moisture holding (Appx Qty is 01 Cum) as directed by EIC shall brought by the contractor and the rate of the same shall deemed to be included In the item rate
-
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
35
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core
50
-
-
Supply and fix 4 Pole MCCB 100 Amp,50 Hz, 415 V with rupturing capacity 25 KA in Sindex box of suitable size all as specified.
2
-
-
M&L for wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC rigid conduit and all accessories fixed concealed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly all as specified.
Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor PVC conduit shall be measured as one length.
5
-
-
M&L for Switch modular type one way 16 Amps , one module
2
-
-
M&L for Modular socket flush type multi purpose 6A/16A-6 pin combined 2 module
2
-
-
M&L for modular metal flush box 3 module
2
-
-
M&L Modular white cover plate with frame 3 module
2
-
-
Taking down aluminium/Copper point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking creditand making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
10
-
-
M&L for Point wiring with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with copper conductor drawn in and including PVC conduit and all conduit accessories concealed and including provision of 1.5 sqmm PVC insulated copper cable FRLSH as earth continuity conductor fabricated branded Modular metal flush box concealed in walls with Modular suitable plate with cover with suitable screws for housing switches socket outlets fan regulators etc all as specified and directed for the following :-
-
-
-
(a) One light point controlled by one one way switch
6
-
-
(b) One Ceiling/exhaust fan point controlled by one one way switch.
1
-
-
(c) One 5Amp socket point on independent board.
15
-
-
All as per Item No 84 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable FRLSH including 2.5 sqmm PVC insulated copper cable as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as specified and directed.
7
-
-
All as per Item No 84 here-in-before but with 4 Sqmm PVC insulated multistranded copper conductor cable FRLSH including 4 sqmm PVC insulated copper cable as earth continuity conductor for one AC point on independent board all as specified and directed.
2
-
-
S&F Switch Modular type single pole oneway 6 amps all as specified and directed.
22
-
-
Supply & Fix modular socket 3 pin 6 Amps flush type all as specified and directed.
15
-
-
S&F Switch Modular type single pole oneway 16 amps all as specified and directed.
7
-
-
Supply & Fix modular socket 3/5 pin 6/16 Amps flush type all as specified and directed.
7
-
-
S&F Fan step regulator, 120W - 2 module
1
-
-
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body on PVC round block all as specified.
7
-
-
Supply and fix and connecting up BLDC ceiling fan of size 1200mm sweep,Speed not less than 310RPM,three blades of 100% rust free,air delivery not less than 225CMM,Power consumption not more than 35Watt,white colour with remote and batteries, complete with and including provision of cable 3 core of size 0.5 sqmm from connector to fan, provision of 3mm thick PVC sheet cover including writing MES No 2cm height with synthetic enamel black paint all as directed.
1
-
-
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface/recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete
6
-
-
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size PVC rigid conduit and all accessories fixed surface/concealed to wall/floors along with one run of 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.
Note: (a) 4 runs of 10 sqmm cable along with one run of 10 sqmm cable for earth conductor PVC conduit shall be measured as one length including taking down UNSV old wiring.
35
-
-
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC rigid conduit and all accessories fixed surface/concealed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.
Note: (a) 3 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor PVC conduit shall be measured as one length including taking down UNSV old wiring.
15
-
-
Supply, fixing and connecting up complete MCB DB TPN 4 way double door, 415 V, AC, 50 Hz, for MCB TPN as incomer and MCBs SP as out going, IP-43 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides complete all as specified and directed.
2
-
-
Supply and fixing miniature circuit breaker (MCB)Triple pole and Neutral 63A rating 415V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning.
2
-
-
Supply and fixing miniature circuit breaker (MCB) Single pole 5 to 32A rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning.
20
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron wire of 4 sqmm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR connected to earting test point all as specified or indicated complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funned with wire mesh 15mm bore GI pipe (light grade) forprotection of earth lead conductor all as directed and testing on completion.
3
-
-
Supply,install, testing and commissioning of Split AC with inverter type, Variable speed compressor which adjusts power depending on heat load, convertible / adjustable with 4 cooling modes through remote control to operate in different tonnages for different cooling needs, comprising of indoor unit with dust Filter, Anti-bacterial Filter & outdoor unit with Copper Condenser Coil, single phase 230V, 50Hz complete with cordless remote control unit of high EER rated BLDC compressor, including inter connection cable of suitable size, necessary fixing arrangement complete unit shall be placed at suitable position and height inside the room and outdoor unit at suitable place outside the room on plinth height / on wall or roof as suitable and including metallic bracket with fixing bolts for outdoor unit, insulated copper piping of suitable length as per site requirement etc, Refrigerant R410-A/R32 of cpapcity 2 TR (copper type) 5 star rated complete all as specified and directed.Note: 1 Year Comprehensive Warranty on the Product and 10 Years on Compressor Make:- CARRIER Model No EASTER-Exl CAI24E5R33FO/ LLYOD MODEL NO GLS2415FWGEV
2
-
-
M& L for AC box modular socket type with MCB SP 25 Amps 10 KA operating on 240 volts AC with plug top all as specified and directed.
4
-
-
S & F single phase, wall mounting type, naturally air cooled indoor type voltage stabilizer of capacity 5.0 KVA for automatic operation; designed for input variation between 170 to 250 Volts and output voltage stabilized to 210 V to 230 V range with over voltage/ under voltage cut off time delay switch complete all as specified and directed.
4
-
-
Supply and fixing hevy duty digital LCD Disply auto AC change over timer switch for cyclic operation of two ACs of 30Amps, 230V all as specified and directed.
5
-
-