Military Engineer Services Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Maintenance Of Defective Ups Servo Voltage Stabilizer And Connected Work Services At Various Locations Of Ina Ezhimala
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_698616_1Tender No
GE MAINT EZHIMALA 8707Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Common Pages, Special Conditions, Particular Specifications, Appendices and Schedule of Credit
BOQ Items
... More
(b) 10 KVA -06Nos
24
-
-
... More
(c) 15KVA -01 Nos
4
-
-
... More
(d) 20 KVA - 04 Nos
16
-
-
... More
(e) 30 KVA - 01 Nos
4
-
-
... More
(f ) 80 KVA -01 No
4
-
-
... More
(g ) 100 KVA- 01 No
4
-
-
... More
Periodical maintenance of servo controlled voltage stabilizer as quartely basis or as pre required basis for checking all power connections of cabling and its terminals, LCD display board, switches, 011, microprocessor based control band data monitoring system, including output voltage and replacement if required for defective part immediately when found complete all as directed by Engr in Charge.
Note:- Spare parts will be measured and paid under relevant items of BOQ.
-
-
-
... More
(a) 10KVA - 06 Nos
24
-
-
... More
(b) 15KVA - 01 No
4
-
-
... More
(c) 30KVA - 01 No
4
-
-
... More
(d) 100 KVA -01 No
4
-
-
... More
Repair in replacement of unserviceable parts with complete servicing of 10 KVA voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 480 V with output voltage stabilized at 415 including testing with complete connections including the following:- (a) Input Voltage Range - 340 Volts to 480 Volts.
(b) Ouput Voltage.
(c) Input Frequency Range - 47 to 53 Hz.
(d) Digital Display.
(e) Accuracy of Voltage - 1% +/- 1 digit.
(f) Under Voltage /Over Voltage.
(g) Short Circuit Protection - HRC Fuse.
1
-
-
... More
Repair in replacement of unserviceable Online UPS Battery of 12 Volts 42 AH SMF including all connection with existng UPS three phase AC input electric supply and output single phase AC supply with testing complete all as specified and directed by Engr-in charge.
80
-
-
... More
Repair in replacement of unserviceable Online UPS Battery of 2 Volts 100 AH SMF (UPST 100) including all connecton with existing UPS, output single phase AC supply with testing complete all as specified and directed by Engr-in-Charge.
110
-
-
... More
Repair in replacement of unservisable Online UPS Battery of 12 Volts 12 AH (Maintenance free Sealed lead acid battery ) of Make - Leoch model no LP-12-12 or equivalant make including all connection with existing system & testing complete after fixing, all as specified and directed by Engr-in-charge.
8
-
-
... More
Repair in replacement of old unserviceable lead acid battery of capacity 12 volt 150 AH of reputed make including charging all as specified and directed by Engineer - in- Charge.
8
-
-
... More
Repair in replacement of old unserviceable lead acid battery of capacity 12 volt 88 AH of reputed make including charging all as specified and directed by Engineer - in- Charge.
7
-
-
... More
Repair/Servicing of unservisable parts of Online UPS including minor parts (except inbuilt isolation transformer, IGBT, Charging Board, MotherBoard) of 30/20/10/5 KVA any capacity to make serviceable including transportation all as specified and directed by Engr-in-charge.
Make:- GE or equivalent in TL Model Mars / APC / EMERSON / MICROTEK.
5
-
-
... More
Supply and fix in replacement of 20/30 KVA UPS Mother board suitable for existing UPS all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply and fix in replacement of 10/20 KVA UPS Charging board suitable for existing UPS all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply and fix in replacement of 10/20 KVA UPS IGBT suitable for existing UPS all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply and fix in replacement of 30 KVA UPS Charging board suitable for existing UPS all as specified and directed by Engr-in-Charge.
1
-
-
... More
Supply and fix in replacement of 30 KVA UPS IGBT suitable for existing UPS all as specified and directed by Engr-in-charge.
1
-
-
... More
M&L for in replacement of sub main wiring complete using 4 run of 10 sqmm and two run of 10 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor ISI marked 1100 V grade in surface/concealed PVC conduit fixed in wall/floor, passing through wall/ceiling complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
M&L for in replacement of sub main wiring complete using 2 run of 10 sqmm and one run of 10 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor ISI marked 1100 V grade in surface/concealed PVC conduit fixed in wall/floor, passing through wall/ceiling complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
Suppy & fix in replacement for fixing sheet metal enclosures DBs 4 way double door with bus bar all as specified and directed by Engr-in-charge.
4
-
-
... More
Suppy & fix in replacement for fixing sheet metal enclosures DBs 8 way double door with bus bar all as specified and directed by Engr-in-charge.
6
-
-
... More
Suppy & fix in replacement for MCB TPN 63 Amps all as specified and directed by Engr-in-charge.
10
-
-
... More
Suppy & fix in replacement for MCB SPN 40 Amps all as specified and directed by Engr-in-charge.
20
-
-
... More
Suppy & fix in replacement for MCB SP upto 40 Amps all as specified and directed by Engr-in-charge.
36
-
-
... More
Repair/servicing of unserviceable parts of battery charger 110 Volts, 15 Amps capacity including minor/major parts (except inbuilt isolation transformer) to make serviceable including transportation to make serviceable complete all as specified and as directed by Engr-in-charge.
3
-
-
... More
Supply and fix in replacement of 10/5KVA UPS motherboard suitable for existing UPS all as specified and directed by Engr-in-charge.
2
-
-
... More
Supply and fix in replacement of 10/5KVA UPS charging board suitable for existing UPS all as specified and directed by Engr-in-charge.
2
-
-
... More
Supply and fix in replacement of 24V, 10 Amps DC suitable for AMF panel /Vacuum circuit breaker complete all as specified and directed by Engr-in-charge.
6
-
-
... More
S&F in replacement of PFC Power PCB-03Nos, Inverter inductor PCB-03Nos, Inverter Power PCB- 02 Nos, including service charge complete all as specified and as directed by Engr-in-charge.
1
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.03 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed by Engr-in-charge.
2
-
-
... More
All as per item No.28 above, but using copper plate 60×60cm× 3.15mm thick electrode and 20×3mm copper strip as earthing lead complete all as specified and as directed by Engr-in-charge.
3
-
-
... More
M&L for filtration and dehydration of transformer oil using filtration plant and testing the die-electric strength of transformer oil and achieving the result of 60 kV and submitting the test report. Provision of necessary stand by DG set required for the power supply for the machine where supply cannot be provided will be the responsibility of the contractor complete all as specified and directed by Engineer in charge.
230
-
-
... More
Supply and topping up of transformer oil confirming to IS 335 in transformers and oil circuit breaker complete all as specified and directed by Engineer in charge.
Note:- Test certificate from the manufacturer should be produced.
135
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%