Local Self Government Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 948Document Cost
₹ 335Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_LSGD_664662_17Bid Award Id
ViewTender No
11/2023-24/EE/LID EWTender Authority
Local Self Government Department ViewPurchaser Address
-Website
http://https://lsgkerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
1
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
5
-
-
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
1
-
-
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1
-
-
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
1
-
-
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
30
-
-
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
15
-
-
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
10
-
-
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1
-
-
90.3.22.3:Supply & installation of light fittings on flat iron bracket <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
3
-
-
OD371261/2023-2024:SUPPLY AND PROVIDING 25X6 MM BRASS BOLT AND NUT WITH WASHERS ON THE EXISTING MS BOX / EARTH BUS ETC. AS REQUIRED INCLUDING DRILLING NECESSARY HOLES AS REQUIRED
2
-
-
OD371262/2023-2024:SUPPLY AND FIXING ANGLE / STRAIGHT BRASS LINED SKIRT TYPE, BAKELITE BATTEN HOLDER WITH 200MM POLISHED SHADE WITH 9W LED AND GIVING CONNECTION ETC AS REQUIRED
1
-
-
OD371263/2023-2024:SUPPLY AND INSTALLATION OF DUST AND VERMIN PROOF WALL MOUNDING METER BOX (300X300X170MM) SINTEX MAKE WITH BASE PLATE SUITABLE TO FIX SINGLE PHASE ENERGY METER AND FIX TO FIX IN THE BOX ONE SET OF 32 A,415 V HRC BAKELITE FUSE FITTING WITH HRC FUSE LINK,32 A 2 WAY NEUTRAL LINK ETC
1
-
-
OD371265/2023-2024:CHARGES FOR PREPARING DRAWING OF THE COMPLETE ELECTRICAL INSTALLATION AFTER COMPLETION OF THE PRESENT WORK AND PREPARING COMPLETION REPORT WITH KSEB SERVICE CONNECTION APPLICATION FORM AND SUBMITTING TO THE CONSUMER FOR AVAILNG 1 PHASE SERVICE CONNECTION/LOAD REGULARIZATION
1
-
-
OD371266/2023-2024:EARTHING WITH G.I. EARTH PLATE 600MM X600 MM X 6 MM THICK WITH WATERING PIPE 1.7 METRE LONG AND TEST JOINT USING 2 NOS ,25X3MM GI STRIP WITH SUFFICIENT DRILLED HOLES MINIMUM SIZE 25 CM SUITABLY SHAPED AND TIGHTLY CLAMPED TO THE WATERING PIPE USING 25X6 MM STEEL BOLTS NUT AND WASHER AND PROVIDING 2 NOS, 20X3 MM GI STRIP FROM TEST JOINT TO EARTH PLATE BOTTOM LEVEL CLAMPED AT 2 LOCATIONS ON THE PLATE AND ON THE TEST JOINT BOLTED WITH STEEL BOLTS,NUTS ETC ,PROVIDING GI FUNNEL WELDED WITH THE WATERING PIPE AND MAKING MASONRY CHAMBER BUILT WITH BRICKS AND DULY PLASTERD AND PROVIDING CAST IRON COVER PLATE ETC COMPLETE
1
-
-
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
30
-
-
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
15
-
-
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
30
-
-
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
10
-
-
OD372618/2023-2024:SUPPLY AND PROVIDING 12X3 MM BRASS BOLT AND NUT WITH WASHERS ON THE EXISTING MS BOX / EARTH BUS ETC. AS REQUIRED INCLUDING DRILLING NECESSARY HOLES AS REQUIRED
5
-
-