Kerala State Film Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Film Development Corporation Limited - KSFDC Tender

Construction Works
Eprocure
Opening Date25 Sep 2021
Closing DateCancelled
Tender Amount₹ 13,33,96,681 
Notes
Download

Costs

Summary

Development And Construction Of Theatre Complex At Vaikkom

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

2

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

2644.43

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

566.65

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

962.26

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

2390.01

-

-

... More
od309911/2020_2021 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/ rock.

714.11

-

-

... More
Concrete works

-

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

10.5

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1.22

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

192.59

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

19.71

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

68.3

-

-

... More
4.13 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

68.3

-

-

... More
R.C.C Works

-

-

-

... More
od313447/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Cement content considered in this item is @ 330 kg/ cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) . All work upto plinth level

546.79

-

-

... More
od313448/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Cement content considered in this item is @ 330 kg/ cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account). All work above plinth level upto floor V level

763.97

-

-

... More
od314610/2019_2020 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account).

236.59

-

-

... More
od119604/2021_2022 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.(Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting,nothing extra shall be paid on this account)

1.94

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

0.2

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

49064.18

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

99189.7

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

432.07

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1183.01

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

2362.11

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

3263.21

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1354.52

-

-

... More
od12089/2020_2021 : Extra for shuttering in circular work : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

27.56

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

668.32

-

-

... More
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards

50

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

328.2

-

-

... More
5.9.17 : Centering and shuttering including strutting, etc. and removal of form for:Cornices and mouldings.

50

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

49.5

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

880.25

-

-

... More
Masonry works

-

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

98.87

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

74.46

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

433.19

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

280.97

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

36.11

-

-

... More
od313439/2019_2020 : Solid block masonry using pre cast sold blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part 1 of 1979 for Super structure above floor two level upto floor five level for 10 cm thick wall in: Cm 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete.

15.19

-

-

... More
od309870/2020_2021 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half thick solid block masonry.

502.75

-

-

... More
Joinery and partition works

-

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

2311.9

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

221.74

-

-

... More
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

43.8

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

9.45

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

9.45

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 6.0 mm thickness

34.28

-

-

... More
21.3.3 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness

39.6

-

-

... More
od313461/2019_2020 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item): With Toughened glass 12 mm thickness

53.69

-

-

... More
od313464/2019_2020 : Supplying And Fixing Hook Lock Glass to Glass for Frameless glass double door with 60mm EPC - both side key , all complete as per approved drawings and as directed by engineer in charge.

4

-

-

... More
21.15.1 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Anodized (AC 15 ) aluminium

6

-

-

... More
21.15.3 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Polyester powder coated minimum thickness 50 micron aluminium

56

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.76

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

47.7

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

102

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

25

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

19

-

-

... More
9.92.1 : Providing and fixing chromium plated brass handles with necessary screws etc. complete:125 mm

10

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

50

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

68

-

-

... More
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm

68

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

163.2

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

36.72

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded)

72

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

7.35

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

17.14

-

-

... More
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm

24

-

-

... More
od314574/2019_2020 : Supplying And Fixing a pair of fire rated Solid SS Lever Handle and Mortise Lock case with Cylinder of approved size and quality for fire rated steel doors etc complete all works including all required fixtures as directed by Engineer in Charge.

8

-

-

... More
od313444/2019_2020 : Providing and fixing 18mm compact laminate, floor mounted Modular Toilet cubicles of approved size , make and Model . Approximate size of cubicle 1200mm(W) X1600MM(D) X 2003mm(H) and approximate door size 610mm (W) X 1750mm (H) using 18 mm thick Compact Laminate of approved colour and finish,SS Shoe legs as per manufacturer specifications, SS Gravity hinges (Right /Left) ,SS Coat Hook with door Stopper,SS Door Knob, SS Lockset with indicator, Aluminium U and F channel , SS Screws & Wall Plugs etc.The rate is Inclusive of cost,carriage of all materials, labour charge, lead & lift etc complete as directed by Engineer-in-Charge at all levels. The rate includes cutting the sharp edges of compact laminate with specialised machinery,additional frame work for suit the ledge wall etc,cutting and making good the wall/floor etc wherever required .The above work shall be carried out by an agency having sufficient experience in this field and only skilled and experienced persons shall be employed for this purpose. Note:Size of the cubicle shall be adjusted to suit the site requirement and the variation if any as per actual site condition shall be done by the bidder without any additional cost.

9

-

-

... More
od313467/2019_2020 : Providing and fixing hinged handicaped toilet door of HPL Board Merino Design/Green Sturdo Classique- Grandeur of greenply or equivalent in single colour, 12mm thick compact laminate of size 1050mmX 2100mm including providing of all accessories like SS Door Frames,D-Post door channel, Gravity hinges, privacy thumb turn c/w occupancy indicator, coat hook, door knob, rubber door, stopper lining and screws & wall etc complete. The rate is inclusive of all hardware labour charges carriage and lead & lift etc. Complete as directed by Engineer in Charge.

1

-

-

... More
od313468/2019_2020 : Providing and fixing hinged / sliding type toilet door of HPL Board Merino Design/Green Sturdo Classique- Grandeur of greenply or equialent in single colour, 12mm thick compact laminate of size 1000mmX 2100mm including providing of all accessories like SS Door Frames,D-Post door channel, Gravity hinges, privacy thumb turn c/w occupancy indicator, coat hook, door knob, rubber door, stopper lining and screws & wall etc complete. The rate is inclusive of all hardware labour charges carriage and lead & lift etc. Complete as directed by Engineer in Charge.

2

-

-

... More
Steel works

-

-

-

... More
od313433/2019_2020 : Steel work in built up tubular sections YST 310 grade as per IS: 4923 including cutting, bending, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes including painting with two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, closing all the open ends properly with same material cost and conveyance of all materials, labour, etc., complete as directed by the Engineer-in-Charge at all levels.

23721.44

-

-

... More
od313434/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

13300.04

-

-

... More
od313440/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, scaffolding, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In stringers, treads, landings etc of staircases including use of chequered plate wherever required, all complete

1659.54

-

-

... More
od309905/2020_2021 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer M.S. tube

200

-

-

... More
od313437/2019_2020 : Providing and fixing stainless steel (Grade 304) glass railing of 1.2m height, made of toughened glass(12mm thick), Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. :For open terrace portion

23

-

-

... More
od314613/2019_2020 : Supplying and fixing rolling shutters of approved make,made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S top cover of required thickness for rolling shutters including two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, including cost and conveyance of all materials, labour charges,lead,lift etc complete as directed by Engineer in Charge at all levels. 80 X 1.25 mm M.S.Laths with 1.25mm thick top cover

7.2

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

3

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

1204.4

-

-

... More
12.14 : Providing flat iron brackets 50x3 mm size with necessary bolts, nuts and washers etc. for fixing asbestos cement / G.S. sheet gutters with purlins.

50

-

-

... More
Flooring Works

-

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

766.34

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

60.54

-

-

... More
od313452/2019_2020 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

78.85

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.

134.37

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

214.49

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

21.52

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

100

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring and skirting in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

64.35

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring and skirting in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

187.86

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

51.06

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

8

-

-

... More
od313460/2019_2020 : Supplying and fixing cement fibre board of thickness approx. 20 mm over steel frame work to act as raised false flooring as per manufactures specifications and approved drawings .The rate shall include cost and conveyance of all materials, labour charges etc. complete for all levels and as directed by the Engineer-in-Charge.

21.87

-

-

... More
Ceiling/Cladding and Roofing works

-

-

-

... More
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board

807.74

-

-

... More
12.45.4 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.

546

-

-

... More
od313441/2019_2020 : Supply and installation of false ceiling using fibre cement board of TPI make manufactured or equivalent of thickness 8 mm and dimension 1220 mm x 2440 mm at all height shall be fixing on GI section 45 x 15 x 0.9 mm running at spacing of 1000 mm centre to centre, to which this ceiling section having its of 10.5 mm , at 450 mm centre to centre , shall be fixing in a direction perpendicular to G.I intermediate channel with connecting clip fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre , with 25 m long dry wall screws @230 mm interval .The rate shall include cost and conveyance of all materials ,labour,scaffolding ,lead ,lift etc complete at all levels as directed by the Engineer- in-Charge .

50

-

-

... More
od313445/2019_2020 : Providing & fixing 8 mm thick (exterior grade cement fibre board panels in required profile over existing wall / Aluminium framework to a height up to 17 m using brass crews and additional adhesive for extra caution . (Aluminium framework will be measured and paid separately under relevant items) . Cement fibre board shall be finished with 2 or more coats of emulsion paint of approved shade over 2 coats of cement primer . Screw heads shall match the same finish and colour of the board with putty and paint /powder coating. The rate shall include cost and conveyance of all materials ,labour,scaffolding ,lead ,lift etc complete at all levels as directed by the Engineer- in-Charge .(Painting will be measured and paid separately under relevant items)

100

-

-

... More
od313435/2019_2020 : Providing & fixing interior grade high pressure compact laminate conforming to IS:2046-1995 of 6 mm thickness over existing grade ply for column and wall cladding using adhesives /double sided tapes .Grooves finished with 10x10mm PVDF coated Aluminium "U" channel of approved size and colour.The rate shall include cost and conveyance of all materials,cutting , polishing, making grooves, cutout for DB doors etc.10mm x10mm size PVDF coated Aluminium "U" Channel in specified joints , labour charges, lead, lift ,scaffolding,etc complete as per drawing and as directed by Engineer-in-Charge at all levels. Wood grain with suede finish.

38.4

-

-

... More
od313438/2019_2020 : Providing & fixing 12 mm thick BWP grade ply confirming to IS- 710 on existing Aluminum/ply frame work or column , wall cladding,ceiling and partition works,framework using 20mm or approved size SS 304 grade screws at every 600 mm center to center . The rate shall include the cost & conveyance of all materials, labour charges, lead, lift , cutting any shapes , provisions for electrical & networking fixtures, hinges, touch latch system, wherever required, ,etc complete as directed by Engineer-in-Charge at all levels.

38.4

-

-

... More
od313442/2019_2020 : Providing & fixing 8 mm thick (exterior grade) wooden textured cement fibre board panels in required profile over existing wall / Aluminium frame work to a height up to 18 m using brass crews and additional adhesive for extra caution. (Aluminium frame work will be measured and paid separately under relevant items) . Screw heads shall match the same finish and colour of the board with putty and paint / powder coating .The rate shall include cost and conveyance of all materials , labour , scaffolding ,lead ,lift etc complete at all levels as directed by the Engineer- in-Charge .

178.37

-

-

... More
od313449/2019_2020 : Design, supply and fixing of PUF Panel in 50mm thick, made out of 0.50mm TCT 300Mpa 150GSM (AZ 150) colour coated Profiled galvalume/zincalume sheets of approved colour (34.5mm crest height in 333.3mm pitch) on the top and 0.50mm TCT 300Mpa 150GSM colour coated galvalume/zincalume slightly ribbed sheet at the bottom with Polyurethane Foam insulation as infill. The colour coating on sheet shall have a total coating thickness of 35 micron comprising of 20 micron Silicon Modified Polyester Paint system of approved colour on the top and 5 micron back up epoxy coating at the bottom over 5 micron primer coating on both sides. The infill insulation material (PUF) shall be fire retardant self extinguishing CFC/HCFC Free and Zero ODP (Ozone Depletion Potential). Polyurethane Foam shall have a density of 40 + 2Kg/M3 in 50mm thick (50 mm + 34.5mm at crest) injected in between the top & bottom sheet using a special foaming machine. The panels will be supplied in 1023mm supply width (1mtr effective width) and length can be as per the site requirement up to a maximum of 12mtr. The panel shall be manufactured from a continuous panel manufacturing line using pentane as blowing agent. The panel shall be directly fixed to the purlins with galvanized imported self drilling and self tapping fasteners with EPDM washers. All the joints will be sealed with sealants and stitched with stitching screws wherever necessary, all complete as per technical specification and as directed by the Engineer-In-Charge.

672

-

-

... More
od313453/2019_2020 : Providing and fixing Gutter ( excluding gutter support) in required width (upto a maximum of 1200mm girth) with plain galvalume/zincalume colour coated sheet made out of 0.5mm TCT, minimum 300 MPa cold rolled steel with hot dip metallic coating of Aluminium Zinc alloy (Galvalume/zincalume) 150 gms/sqm,total of both sides, AZ 150 as per ASTM A 792 or AS1397, with polyester colour coating including cost and conveyance of all materials, scaffolding, lead,lift, labour charges etc. complete at all levels as directed by Engineer-in-Charge

50

-

-

... More
od313455/2019_2020 : Providing and fixing ridge/ valley capping/flashing in required width (upto maximum 600 mm) with plain galvalume/zincalume colour coated sheet made out of 0.50mm TCT, minimum 300 MPa cold rolled steel with hot dip metallic coating of Aluminium Zinc alloy (Galvalume/zincalume) 150 gms/sqm,total of both sides, AZ 150 as per ASTM A 792 or AS1397, with polyester colour coating including cost and conveyance of all materials, scaffolding, lead,lift, labour charges etc. complete at all levels as directed by Engineer-in-Charge

508.2

-

-

... More
Finishing works

-

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

10496.92

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

2548.9

-

-

... More
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)

808.31

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

996.29

-

-

... More
13.23.2 : Extra for plastering on circular work not exceeding 6 m in radius.In two coats

100

-

-

... More
13.24.2 : Extra for plastering done on moulding cornices or architraves including neat finish to line and level:In two coats

100

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

10350.52

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

11158.26

-

-

... More
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

308.66

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

1262.75

-

-

... More
13.40 : Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:

148.51

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

346.5

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

2077.53

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be appliedas intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5mm thickness after scrapping and properly cleaning the surface to remove looseparticles from the plaster surface, followed by top coating with Premium AcrylicSmooth exterior paint with Silicone additives of required shade by two or morecoats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

721.78

-

-

... More
od314575/2019_2020 : Providing and applying melamine matt finish on wood work after scraping and cleaning the surface applying necessary coats of putty, filler and sealer, etc. Sanding shall be done along the grains using water paper/emery paper before applying filler, sealer and melamine to get a perfectly smooth and uniform finish. Melamine and sealer shall be applied using spary gun. The rate shall include cost and conveyance of all materials, lead lift, all labour

124.03

-

-

... More
od12094/2020_2021 : Design, providing and installation of mural art on wall with acrylic paints of required design by approved Artist/Architect approved by Engineer in charge. Clear varnish of approved make is sprayed over the painted surface as protective coating. The art work shall generally depict dance forms, martial arts, folk arts, landscape etc .The painting work to be done on masonry finished surfaces. The size shall be decided by the artist and architect.The acrylic paints used should be Water proof,UV resistant and of high quality.The rate shall include providing and applying mural art on wall including professional charge of approved artist using approved tools and materials, with all labours (including necessary Scaffolding ), up to required height as per the directed by Engineer in charge.

105.32

-

-

... More
od12095/2020_2021 : Design, providing and installation of mural art on glass surface with acrylic paints of required design by approved Artist/Architect approved by Engineer in charge. clear varnish of approved make is sprayed over the painted surface as protective coating. The art work shall generally depict dance forms, martial arts, folk arts, landscape etc .The painting work to be done on glass surfaces. The size shall be decided by the artist and architect.The acrylic paints used should be Water proof,UV resistant and of high quality. The rate shall include providing and applying mural art on wall including professional charge of approved artist using approved tools and materials, with all labours (including necessary Scaffolding ), up to required height as per the directed by Engineer in charge.

105.35

-

-

... More
Road and Parking area works

-

-

-

... More
16.1 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

1140

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

44.55

-

-

... More
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

99

-

-

... More
16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade

43.2

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

285

-

-

... More
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

1140

-

-

... More
Miscellaneous works

-

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

1

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

1

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

1

-

-

... More
19.7.3.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x 90 cm and 90 cm deep including C.I. cover with frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg ( weight of cover 108 kg and weight of frame 100 kg)With common burnt clay F.P.S. ( non modular) bricks of class designation 7.5

3

-

-

... More
od313432/2019_2020 : Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate 0.075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )

1100

-

-

... More
od313446/2019_2020 : Providing and fixing Queue manager posts in stainless steel 202 grade having height 910mm and base diameter 320 mm with tube of 63.5 mm diameter . The length of the rectractable polyester tape is approx. 2.25 m. The tape shall be 48mm in width. The overall weight of the post will be approx. 8.5kg with cassette consisting of three receiving and one extension end for four way connectivity. The rate is including cost and conveyance of all materials, labour charges, sundries,lead,lift etc complete as directed by the Engineer in charge at all levels.

6

-

-

... More
od314614/2019_2020 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

6

-

-

... More
od314691/2019_2020 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

3

-

-

... More
od313450/2019_2020 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 200 mm dia RCC pipes.

50

-

-

... More
od313458/2019_2020 : Providing and laying non-pressure NP4 class (heavy duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: 300 mm dia R.C.C. pipe

78

-

-

... More
od313459/2019_2020 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 450 mm dia RCC pipes.

32

-

-

... More
od119599/2021_2022 : Providing and constructing soak pit 1.5 m x 1.5 m x 1.5 m size with honey comb brick work on the sides upto a height of 0.9m and brick masonry in CM 1:6 for the balance height, providing and filling brick bats graded, upto a height of 1.2 m, providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials, labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

2

-

-

... More
Waterproofing works

-

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

511.28

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

100.09

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

827

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction ofEngineer-in-Charge.

633.4

-

-

... More
Façade and Glazing works

-

-

-

... More
od313462/2019_2020 : Design supply and installation of spider glazing as per architectural drawings with minimum 12mm clear toughened glass using SS 316 grade Spiders , fixed bolts, Bushes of approved make, necessary sealant and all other fasteners which confirm to wind load and static load calculations to form grids. Cost shall be including all labour, lead, fabrication charges, cost of all consumables, etc as directed by the Engineer in charge.Fabrication drawing shall be submitted and got approved prior to the execution

60.72

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account).

801

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing (with open joints) for linear as well ascurvilinear portions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings for the specifieddesign loads conforming to IS 875 part III (the system must passed the proof testat 1.5 times design wind pressure without any failure), including functional designof the aluminum sections for fixing glazing panels of various thicknesses, aluminiumcleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clampsetc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmokeseals, microwave cured EPDM gaskets for water tightness, pressureequalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3Dimentional movement for achieving perfect verticality and fixing structural glazingsystem rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetalliccontacts with nuts and washers etc. of stainless steel grade 316, of the requiredcapacity and in required numbers.c) Providing and filling, two part pump filled, structural silicone sealant and onepart weather silicone sealant compatible with the structural silicone sealant ofrequired bite size in a clean and controlled factory / work shop environment ,including double sided spacer tape, setting blocks and backer rod, all of approvedgrade, brand and manufacture, as per the approved sealant design, within and allaround the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thickand of sizes, shapes and profiles, as required as per the site conditions, to seal thegap between the building structure and all its interfaces with curtain glazing tomake it watertight.e) Making provision for drainage of moisture/ water that enters the curtain glazingsystem to make it watertight, by incorporating principles of pressure equalization,providing suitable gutter profiles at bottom (if required), making necessary holesof required sizes and of required numbers etc. complete. This item includes costof all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges includingwastages etc., enabling temporary structures and services, cranes or cradles etc.as described above and as specified. The item includes the cost of getting all thestructural and functional design including shop drawings checked by a structuraldesigner, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of theindividual components for testing in an approved laboratory, field tests on theassembled working structural glazing as specified, cleaning and protection till thehanding over of the building for occupation. In the end, the Contractor shall providea water tight structural glazing having all the performance characteristics etc. allcomplete as required, as per the Architectural drawings, as per item description,as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extrudedaluminium section capping for fixing in the grooves of the curtain glazing andvermin proof stainless steel wire mesh shall be paid for separately under relevantitems under this sub-head. However, for the purpose of payment, only the actualarea of structural glazing (including width of grooves ) on the external face shallbe measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazingsystem if area of structural glazing exceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board for Testing and CalibrationLaboratories), Department of Science & Technologies, India. Cost of testing ispayable separately. The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing systemTests to be conducted in the NBL Certified laboratories1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to+300pa) as perASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testingmethod for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testingmethod for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testingmethod for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method forQualitative test” Tests to be conducted on site6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)upto 2000ml”

80.1

-

-

... More
25.3 : Providing, assembling and supplying vision glass panels (IGUs) comprising ofhermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel unitsof size and shape as required and specified, comprising of an outer heatstrengthened float glass 6mm thick, of approved colour and shade with reflectivesoft coating on surface # 2 of approved colour and shade, an inner Heat strengthnedclear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primaryseal and secondary seal (structural silicone sealant) etc. all complete for the requiredperformances, as per the Architectural drawings, as per the approved shopdrawings, as specified and as directed by the Engineer-in-Charge. The IGUs shallbe assembled in the factory/ workshop of the glass processor. (Payment for fixingof IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment,only the actual area of glass on face # 1 of the glass panels (excluding the areas ofthe grooves and weather silicone sealant) provided and fixed in position, shall bemeasured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating onface # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved makehaving properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflectioninternal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performanceglass shall be decided by technical sanctioning authority as per the site requirement

66.9

-

-

... More
25.4 : Extra for openable side / top hung vision glass panels (IGUs) including providingand supplying at site all accessories and hardwares for the openable panels asspecified and of the approved make such as heavy duty stainless steel frictionhinges, min 4 -point cremone locking sets with stainless steel plates, handles,buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts,washers etc. all complete as per the Architectural drawings, as per the approvedshop drawings, as specified and as directed by the Engineer-in-Charge.

8.01

-

-

... More
25.6 : Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass panels in the curtain glazing is included in cost of relevent item*).(ii) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face #2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35%, Light reflection internal 10 to 15%, light reflection external 10 to 20%, shading coefficient (0.25 - 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

13.2

-

-

... More
25.8 : Design supply & installation of suspended Spider Glazing system designed towithstand the wind pressure as per IS 875 (Part-III). The Suspended Systemheld with Spider Fittings of SS-316 Grade Steel of approved manufacturer withglass panel having 12 mm thick clear toughened glass held together withSS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins21 mm thick. The Glass fins and glass panel assembly shall be connected toSlab/beams by means of SS- 316 Grade stainless steel brackets & Anchor boltsand at the bottom using SS channel of 50x25x2mm using fastener & anchorbolts, non staining weather sealants of approved make, Teflon/ nylon bushesand separators to prevent bi-metallic contacts, all complete to perform as perspecification and approved drawings. The complete system to be designed toaccommodate thermal expansion & seismic movements etc. The joints betweenglass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assemblyto be filled with non staining weather sealant, so as to make the entire systemfully water proof & dust proof.The rate shall include all design, Engineering and shop drawing includingapproval from structural designer, labour, T&P, scaffolding, other incidentalcharges including wastage, enabling temporary services all fitting fixers nutbolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc.all complete. For the purpose of payment, actual elevation area of Glazingincluding thickness of joints and the portion of Glass panel inside the SS channelshall be measured.

33

-

-

... More
od313443/2019_2020 : Design, supply & installation of Spider Glazing system for roofing work designed to withstand the wind pressure with 12mm thick toughened glass using Spiders fixed bolts, Bushes of approved make, assembly over existing steel structure of roof. The rate shall include all design, Engineering and shop drawing, labour, scaffolding, other incidental charges including wastage fastener, anchors. all complete as directed by the Engineer in charge

48

-

-

... More
SANITARY WORKS

-

-

-

... More
od311757/2019_2020 : Providing and fixing of star white vitreous china under counter wash basin of 550 X465X190 mm size or equivalent of approved make including one CP brass pressmatic pillar cock 15mmNB including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling, 32mm dia CP brass bottle trap,CP brass 15mm angle valve,complete including CI/MS brackets duly painted, nuts, washers, etc. complete,cost and conveyance of all materials labour charges ,lead, lift necessary wall cutting / chasing and making good the walls,floors,slab,testing and commissioning to the satisfaction ofEngineer in charge at all levels. (Model no: Queo Q757150310+Jaquar PRS-031+JaquarOPP- 15053PM+Jaquar ALD-769L300+Jaquar ALD-709L130 or Models no: Grohe catalogue no:470LMRWT+Kohler Catalogue no: 20747IN-CP.+Queo Catalogue no:Q503191120+Q503195220+Q503191520 orequivalent).

10

-

-

... More
od311758/2019_2020 : Providing and fixing floor trap with cockroach trap (multi trap), concealed or exposed, SS304 grade floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer-in-Charge at all levels

20

-

-

... More
od311759/2019_2020 : Providing and fixing C.P. brass concealed stop cock (control valve) of standarddesign and of approved make conforming to IS:8931 etc. including cost and conveyance of all materials,labour charges, lead,lift, necessary wall cutting / chasing and making good the walls,floor,slab etc complete,testing and commissioning to the satisfaction of Engineer in charge at all levels.(Model-Jaquar catalogueno:ALD - CHR-089+ FLR-CHR-5083NK or Queo catalogue no: Q503152720 or equivalent).

8

-

-

... More
od311760/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame Round Frame with Flat Round Cover with Rubber Seal SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels. 75mm dia

9

-

-

... More
od311761/2019_2020 : Providing and fixing CP brass robe hook etc complete testing and commissioning to the satisfaction of Engineer at all levels. (Model-Jaquar catalogue no:AQN-7791 or Queo catalogueno: Q363196120 or equivalent).The rate is including cost and conveyance of all materials, labourcharges, lead,lift ,cutting and making good the walls,floors,slab etc complete as directed by the Engineerin charge at all levels

12

-

-

... More
od311762/2019_2020 : Providing and fixing frameless mirror, with all four edges machine polished and back side protected with safety film and 4 mm thick Plywood backing and fixed on walls with mirror screws. The rate includes lifting, cutting etc. as per drawing.

10

-

-

... More
od311763/2019_2020 : Providing and fixing liquid soap dispenser of approved make including costand conveyance of all materials labour charges ,lead, lift, cutting and making good the walls, floors andslab wherever required etc complete, testing and commissioning to the satisfaction of the Engineer inCharge atall levels .(Model:Jaquar catalogue no SDR-WHT-DJ0010F or Euronics ES 06-A or equivalent)

6

-

-

... More
od311764/2019_2020 : Providing and fixing of star white vitreous china urinal division plate ofapproved quality and make with fittings/fastener including cutting and making good the walls,floors,slab,cost and conveyance of all material, labour charge, lead, lift, all taxes etc. complete as directed by theEngineer in charge at all levels.(Model:Hindware catalogue no: F61001 or equivalent)

12

-

-

... More
od311765/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame Round Frame with Flat Round Cover with Rubber Seal SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels. 110mm dia

6

-

-

... More
od311766/2019_2020 : Providing and fixing CP brass body bib cock etc. complete including costand conveyance of all materials labour charges ,lead, lift,including cutting and making good the walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at alllevels. (Model:Jaquar catalogue no KUP-35037PM or Queo catalogue no:Q113113120 or equivalent) .

12

-

-

... More
od311767/2019_2020 : Providing fixing star white vitreous china flat back urinal with CP brass flushvalve auto closing system with built in control cock and wall flange of approved size with all accessoriesto provide satisfactory functioning including cost and conveyance of all materials, labour charges ,lead,lift necessary wall cutting / chasing and making good the walls,floors,slab, as required for urinal flushingetc complete, testing and commissioning to the satisfaction of Engineer in charge at all levels.(Model:Jaquar catalogue no: URS-WHT-13261+PRS-077or Hindware catalogue no:60002+Grohe catalogueno:36268000 or equivalent).

12

-

-

... More
od311768/2019_2020 : Providing fixing of star white vitreous China European wall hung pan with softclose seat and lid with CP brass hinges and rubber buffers with concealed dual fushing cistern 3/9 litrewater storage with chrome finish wall plate actuator etc complete including all accessories, cost andconveyance of all materials, labour charges,lead, lift ,necessary wall cutting / chasing and making goodthe walls,floors,slab, testing and commissioning to the satisfaction of Engineer in charge at all levels.(Model no: Queo catalogue no: Q357240110+Q507450100+Q507455120 or Model no: Jaquar Catalogueno: VGS-WHT 81953 +JCS-WHT- 2400 + JCP-CHR-152415 or equivalent).

11

-

-

... More
od311769/2019_2020 : Providing and fixing hand dryer of approved quality and make including costand conveyance of all materials labour charges ,lead, lift ,cutting and making good the walls and floorsetc complete as directed by the Engineer in charge at all levels.(Model-Jaquar catalogue HDRWHT- M04Aor Euronics catalogue no: EH22 or equivalent)

4

-

-

... More
od311770/2019_2020 : Providing and fixing CP brass swan neck sink cock of approved make and quality including cost and conveyance of all materials,labour charges,lead,taxes etc complete to the satisfaction of Engineer in Charge at all levels.(The purchase price(inclusive of all taxes) of CP brass swan neck sink cock and any deviation plus or minus in the purchase price of approved make will be adjusted (will be paid extra or deducted ) while making payment to the contractor).

1

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

1

-

-

... More
od311774/2019_2020 : Providing and fixing sanitary fixtures for handicaped toilet including one wash basin of size 65 x 35cm, one pair mounting brackets,one number pillar cock all other related fittings likebottle trap ,angle cock,waste coupling, etc,one number EWC Cistern complete with fittings seatcover, one no. hinged rail 76cm 4nos. of grab rails 60cm etc designed for people with special needscomes with as per manufactures specification including cutting and making good the walls and floorswherever required as per drawing and as directed by Engineer in charge. (Model no: Hindwareno:70002+Jaquar OPP- 15001PM+Jaquar ALD-709L130+Jaquar ALD-769L300+Jaquar OPP- 15053 or Ceracruse set+Queo catalogue no:Q113112120 + Q503191120 +Q503195220 +Q503191520 or equivalent)

1

-

-

... More
od311776/2019_2020 : Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer-in-Charge at all levels

7

-

-

... More
18.19.1.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):25 mm nominal boreHorizontal

2

-

-

... More
18.19.2.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):32 mm nominal boreHorizontal

1

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

12

-

-

... More
WATER SUPPLY

-

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

110

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

30

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

36

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

18

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

6

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

1

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

2

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

1

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

2

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

6

-

-

... More
18.33.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

9

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

1

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

4

-

-

... More
od311771/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <40mm dia>

2

-

-

... More
od311772/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <50mm dia>

4

-

-

... More
od311773/2019_2020 : Supply and erection of dual media filter of size 0.6m dia x 1.2 m HOS, (approx.) vertical type pressure vessel, mild steel internally and externally epoxy coated, 6mm shell thickness, 6mm dish thickness, flanged top and bottom, operating pressure of 3.5 Kg/cm2, complete with CI valves and graded pebble and sand as media, frontal piping, pressure gauges, strainers, supporting structure, back wash arrangement, etc and all other accessories. Flow rate - 5 m3/hr

1

-

-

... More
od311775/2019_2020 : Providing and fixing cast iron fabricated Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation and connection, flanges etc. including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge 50mm 'Y' type strainer

2

-

-

... More
od311777/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge. 65mm Dia

5

-

-

... More
od311778/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mm

2

-

-

... More
od311779/2019_2020 : Supplying, laying, jointing, testing and commissioning to the satisfaction of Engineer in charge of hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps including cutting and making good the walls,testing the lines rectifying any leakages or defects,etc. complete for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for concealed work as directed by the Engineer- in-Charge. MAKE: Astral/Ajay/Ashirvad or equivalent 50mm dia(6 kg/cm2)

60

-

-

... More
od311780/2019_2020 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge 75mm OD (6 kg/cm2)

90

-

-

... More
od311781/2019_2020 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge 75mm OD (4 kg/cm2)

72

-

-

... More
od311782/2019_2020 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge 110mm OD(6 kg/cm2)

215

-

-

... More
od311783/2019_2020 : Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.

4

-

-

... More
od311784/2019_2020 : Providing and fixing 110mm dia PVC vent cowl to pipe already fixed as directed by Engineer-in-charge at all levels. 110mm dia

4

-

-

... More
od311785/2019_2020 : Providing and fixing PVC vent cowl to pipe already fixed as directed by Engineer-in-Charge at all levels.75 mm dia

8

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

-

-

... More
2.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia

30

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

130

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

90

-

-

... More
od311786/2019_2020 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling testing of joints complete as per direction of Engineer in Charge. 200 mm dia 6 Kgf/cm2

6

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

100

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

30

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

186

-

-

... More
od311787/2019_2020 : Supplying, laying, jointing, testing and commissioning to the satisfaction of Engineer in charge of hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps including cutting and making good the walls,testing the lines rectifying any leakages or defects,etc. complete for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for concealed work as directed by the Engineer- in-Charge. MAKE: Astral/Ajay/Ashirvad or equivalent 110mm dia

30

-

-

... More
od311788/2019_2020 : Supplying and installing activated carbon filter of 5 cum/hr with internally and externally epoxy coated, raw water distributor, filter water collecting system, pressure gauges at inlet and outlet, strainers, supporting structure, back wash arrangement, set of inlet and outlet valves, V-notch Board etc and all other accessories .The rate shall include cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.

1

-

-

... More
od311789/2019_2020 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency Capacit: 5 m3/hr,Head : 35m

2

-

-

... More
od311790/2019_2020 : Chemical dosing system Supplying and fixing of electronic dosing pump with all wetted parts in PP construction suitable for pumping HOCl solution including cost of valves, suction and delivery lines using heavy duty PVC tubes, FRP tank of 80 litres capacity, FRP motor cover etc. and complete with all accessories. Capacity : 6 lph @ 3.5 kg/cm2

1

-

-

... More
od311791/2019_2020 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels Capacity: 10m3/hr,Head: 28 m

4

-

-

... More
od311792/2019_2020 : Providing and fixing enclosed type water meter (bulk type) 50mm dia conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.

1

-

-

... More
od311793/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 200mm dia

2

-

-

... More
od311794/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 100mm dia

2

-

-

... More
od311795/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 80mm dia

1

-

-

... More
od311796/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 65mm dia

4

-

-

... More
od311797/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 200mm dia

2

-

-

... More
od311798/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 150mm dia

2

-

-

... More
od311799/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 100mm dia

4

-

-

... More
od311800/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 80mm dia

3

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

10

-

-

... More
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

1

-

-

... More
od311801/2019_2020 : Providing and fixing C.I. basket type dirt box strainer for bulk type water meter with nuts, bolts, all accessories etc. complete conforming to IS : 2373 : including cost and conveyance of all materials, labour etc. complete and as directed by Engineer in charge 65mm dia

1

-

-

... More
od311802/2019_2020 : Supply and installation of water level indicator with electronic integrated circuit and necessary accessories etc complete as directed by the Engineer in charge at all levels

3

-

-

... More
od311803/2019_2020 : Supplying,installing, testing and commisioning of electronic integrated circuits and wireless water level controller including necessary cabling and transformers with all accessories etc complete as directed by Engineer in charge for water supply level control in water tanks

3

-

-

... More
od311804/2019_2020 : Providing and fixing enclosed type water meter (bulk type)80mm dia conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.

1

-

-

... More
od311805/2019_2020 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80 mm dia

8

-

-

... More
od311806/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot cold water supply, including all CPVC plain brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 65mm nominal dia

66

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

6

-

-

... More
od311807/2019_2020 : Supplying ,fixing, testing and commissioning of portable drainage pump with 12mm solid handling, with stainless steel construction, stainless steel impeller complete with motor , with carrying handle and all accessories and working with 415V, 3ph and 50 Hz frequencyCapacity:10m3/hour,Head-15m

1

-

-

... More
od311808/2019_2020 : Providing and fixing CI Y type strainer 65mm dia rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge Other Engineering Organisations P R I C E 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge

1

-

-

... More
od311809/2019_2020 : Providing and laying non-pressure NP4 class (heavy duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: 300 mm dia R.C.C. pipe

12

-

-

... More
od311810/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 65 mm

1

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal

2

-

-

... More
od311811/2019_2020 : Providing and fixing C.I. grating 150x150 mm as directed by the Engineer-in-charge

6

-

-

... More
50.18.8.1.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2

6

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

60

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

120

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

24

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

18

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

36

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

6

-

-

... More
18.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipes

6

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

1

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.75

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.75

-

-

... More
od311812/2019_2020 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency Capacity : 5 m3/hr,Head: 35m

1

-

-

... More
od311813/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <40mm dia>

1

-

-

... More
od311814/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot cold water supply including all CPVC plain brass threaded fittings. This includes jointing of pipes fittings with one step CPVC solvent cement, trenching , refilling testing of joints complete as per direction of Engineer- in-Charge. External work 80 mm nominal inner dia pipes

30

-

-

... More
HT EQUIPPMENTS LT PANEL BOARDS

-

-

-

... More
od143117/2021_2022 : Supply, Installation testing and commissioning of 11 KV DP structure using 200x100 mm ISMB for poles and cross channel of ISMC 100x50mm and supporting structure for 11 KV components with 65x65x6 mm MS angle bracings between consumer and supplier structure,cross arms,11 KV pin,disc and stay insulators, supports, jumpering / interconnecting conductors with '0'SWG Cu, anticlimbig arrangement using barbed wire,earthing etc. on a suitable concrete foundation including the civil foundation .The DP structure shall consists of the following (Note:All the MS items shall be hot dip galvanised) 11 KV,400A ,TP,AB switch - 1 No. 11 KV Lighting Arrestor -1 set of 3 Nos 11 KV DO fuses-1 set of 3 Nos

1

-

-

... More
od143168/2021_2022 : HT Meteing Kiosk Supply, installation, testing and commissioning of Outdoor (IP54) Bi directional TOD Metering kiosk and test terminal block, control fuses,armoured copper cable between CTPT unit and TOD meter, totally enclosed, free standing, floor mounting, dust vermin proof, indoor cubicle type, made of 14SWG sheet steel powder coated with necessary cable alley busbar chamber. The panel shall be with 630A aluminium PVC sleeved busbar support insulators, space heater with thermostat, cubicle illumination lamp, MCBs for AC/DC Control etc, seal off bushings, control wiring etc.The KIOSK shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54, weather proof,undergone seven tank process,powder coated finish ,earthing,entire civil work including suitable foundation and all mounting accessories as required complete as per the requirement of K.S.E.B " HT HRC fuse 50A - 3 nos Seal off Bushing - 1 set 11kV CT(0.2S) and 11kV/110V PT(0.2) units-1set 50/5A ,110V Class 0.2s bidirectitonal TOD meter- 1no Shunt trip coil, 230V AC - 1 set Space heater with thermostat - 1 set Suitably rated Aluminium busbars and support insulators ON-OFF indication- 1 set The rate is inclusive of transportation, insurance, lift, lead and all associated works. The panel shall be with bottom entry to receive incoming outgoing cable, all necessary interconnection accessories as per particular specification single line diagram.

1

-

-

... More
od143173/2021_2022 : Supplying and filling the proposed yard with 40 mm size blue jelly of 150 mm thick including cost and conveyance of all materials, labour charges etc. complete.

4

-

-

... More
od143188/2021_2022 : Supply, installation, testing and commissioning of 1 No. outdoor 320 kVA, 415V, 3 phase, 1500 R.P.M, 0.8 PF(Continuous duty), water cooled, radiator type, four stroke, electric start prime duty, floor mounted Diesel Generator set with acoustic enclosure (outdoor duty) and all accessories including supply and installation of standard control panel with metering and protections,controls and interlocks, suitable MCCB for Overcurrrent Earth Fault Protection, CTs and transducers for all metering and protection, Antivibration mountings, exhaust silencer and exhaust pipe along with Acoustic Enclosure(sound pressure level as per ISO standards), electric starter, batteries battery charger, fuel tank suitable for 8 hrs of continuous operation with level indicator, radiator, necessary control wiring with control cables, first fill of lubricating oil, and Diesel for testing and commissioning, earthing as per standards and all accessories as required. The rate shall be inclusive of all lift,lead, first fill of oil etc. The work should be as per Electrical Inspectorate/ Central Pollution control board standards.

1

-

-

... More
od143259/2021_2022 : MSB PANEL Supply, Installation, Testing and Commissioning of LT Switch Board (MSB), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification.The panel shall be of form 4 type construction and shall have provision for fire suppression system. " Incomer -630A FP, 36 kA, Microprocessor based Moulded Case Circuit Breaker - 2 No " 630A FP ATS with AMF relay- 1no Instruments 4A, C curve SP MCB -2 sets RYB indication lamp, LED type - 2 sets (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch -2 sets (0-630)A ammeter Acc. class 1 with 90 deg defl. scale - 2 Nos 630/5A 15VA class 1 resin cast CT - 2 nos ON/OFF/TRIP indication lamp, LED type - 2 sets Busbar 700A TPN busbar chamber with Aluminium busbar with 630A FP MCCB as buscoupler Out goings "Surge Protection Devices for Main Panel: Class B Class C- 1 set The panel should include Pluggable type surge arrester Class B Class C/ Class 1 Class 2 as per IEC 61643 " 200A, 36kA TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36kA) -1 no The Provision for of Energymeter and cutout fuses for Commercial Loads as per SLD -4 no 320 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu=36KA) -1 no 160 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu=36KA) - 2 no 125 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA) - 4 no 320 A FP SDU -1 no ON/OFF INDICATION LAMP -as per SLD

1

-

-

... More
od143277/2021_2022 : 90 KVAR APFC PANEL Supply, Installation, Testing Commissioning of Capacitor Panel Board , cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc., including provision for capacitor mounted inside the panel with adequate number of louvers and powder coated with approved shade and having following specific components all inter connections and following components as per drawing and technical specifications. Theb panel shall be of Form 3b construction. Incomer 200 A,25kA FP MCCB with adjustable thermal magnetic release with OL SC protection - 1 no. Instruments 4A, C curve SP MCB - 3 no RYB indication lamp, LED type - 3 no. (0-500)V voltmeter, Acc. class 1 with 90 deg defl. scale - 1 no. (0-200)A ammeter Acc. class 1 with 90 deg defl. scale - 1 no 6A 3 pole voltmeter selector switch - 1 no. 6A 3 pole Ammeter selector switch - 1 no. 200/5A 15VA class 1 resin cast CT - 3no Microprocessor based intelligent, 6 step IPFC relay with PF display - 1 No. Auto / manual selector switch - 1 no. ON-OFF -TRIP indication lamp - 1 set. Busbar 200A TPN busbar chamber with Aluminium busbar. Outgoing 100A, 25kA, TP MCCB with adjustable thermal magnetic release with OL SC protection -2 no 32A, 25kA, TP MCCB with adjustable thermal magnetic release with OL SC protection - 5 no 30 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type)- 2 No 10 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 1 No. 5 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 2 No. 30 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 2No 10 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor -3 No 5 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 2 No Control wiring required for no load compensation capacitor

1

-

-

... More
od143285/2021_2022 : Pump panel Supply, Installation, Testing and Commissioning of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.TThe panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The panel shall be of form 4 type construction. Incomer 63 A,25kA FP MCCB with adjustable thermal magnetic release with OL SC protection - 1 no. BUSBARS 100 Amp TPN busbars of high conductivity electrolytic quality aluminium conductor INSTRUMENTS Voltmeter (0 to 500 V) for 3 phase, 4 wire operation with selector switch and 3 Nos. control MCBs -1 Set Ammeter (0 to 40A) with selector switch and 3 nos 40/5A CT's, 15VA, Class 1for 3phase, 4 wire operation -1 Set RYB phase indicating lamps, LED type -1 Set 4 A MCB -3 no Outgoing 32 A 25kA TPN SDFU with suitable HRC fuses - 9 Nos. On/Off indication lamp, LED type for out goings - 7set. 3 phase DOL starter with on/off push button,thermal overload relay, single phasing preventer and auxillary power contactors for 3 HP motor - 4 no 3 phase DOL starter with on/off push button,thermal overload relay, single phasing preventer and auxillary power contactors for 2 HP motor - 3 no. Space provision for fixing 3 phase DOL /star-delta starter with on/off push button, thermal overload relay, single phasing preventer and auxillary power contactors ON/OFF indication lamps,capacitors in spare outlets

1

-

-

... More
od143286/2021_2022 : HVAC PANEL Supply, Installation, Testing and Commissioning of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.TThe panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The panel shall be of form 4 type construction. and shall have provision for fire suppression system. Incomer 320A FP ,36kA MCCB with adjustable thermal magnetic release with OL SC protection-1 No Busbar 400A TPN busbar chamber with Aluminium busbar Meters 4A, C curve SP MCB - 1 No RYB indication lamp, LED type - 1 No (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch - 1 set (0-320) A ammeter Acc. class 1 with 90 deg defl. scale with Ammeter Selector Switch- 1 set 320/5A 10VA class 1 resin cast CT - 3no Outgoings 63 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA) -5 no 100 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA) -2 no "63/5 A, 3 ph energymeter of accuracy class 1 with RS485 communication port -2 no 100/5 A ,3 ph energymeter of accuracy class 1 with RS485 communication port -2no 100/5 A, 15 VA, class 1,resin cast CT -2 no" The panel shall be with bottom entry to receive incoming outgoing cable, all necessary interconnection accessories as per particular specification single line diagram.

1

-

-

... More
od143300/2021_2022 : Fire Panel Supply, Installation, Testing and Commissioning of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.TThe panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The panel shall be of form 4 type construction. Incomer 320 A 36kA FP SDFU with suitable HRC fuses - 1 set BUSBARS 400 A TPN busbars of high conductivity electrolytic quality aluminium conductor INSTRUMENTS Voltmeter (0 to 500 V) for 3 phase, 4 wire operation with selector switch and 3 Nos. control MCBs -1 Set Ammeter (0 to 320A) with selector switch and 3 nos 320/5A CT's, 15VA, Class 1for 3phase, 4 wire operation -1 Set RYB phase indicating lamps, LED type -1 Set 4 A MCB -3 no Outgoing 125A 36kATPN SDFU with suitable HRC fuses - 3 sets 63A 36kA TPN SDFU with suitable HRC fuses - 2 sets 32A 36kA TPN SDFU with suitable HRC fuses - 2 sets 25A DP MCB - 1 no On/Off indication lamp, LED type for out goings - 7set. 3 phase star delta starter suitable for 75 HP main electric pump - 2 no 3 phase star delta starter suitable for 12.5HP jockey pump - 2 no. "Space provision for fixing 3 phase DOL /star-delta starter with on/off push button, single phasing preventer and auxillary power contactors ON/OFF indication lamps,capacitors in spare outlets. Diesel Engine Control - 1 No. , Each Diesel engine control consisting of: 25A DP C curve control MCB, 25A On/off control switch - 2 No. , 3 attempt starting device, push button etc., All required timers, relays, fuses and accessories for automatic operation of diesel engine. Indication lamp for high water temperature, engine fail to start, engine On indication, high/low lube oil pressure. Necessary control wiring for start / stop solenoid, line / oil pressure switch, temperature switch, pressure switch to fire pump panel, diesel engine control panel to fire pump panel etc. Battery Charger suitable for 12 V / 24 V DC with boost and trickle selector switch, 0 -15 V / 0 - 30 V DC volt meter, 0 - 20 A DC Ammeter - 02 No. 6 panel annunciation window for fault indication with hooter, accept reset push button, separate hooter for Diesel /electrical pump on running condition - 1 No The system shall include all accessories to control the operation of main electric pump, diesel pump, jockey pump as per the operating sequence for the fire fighting system indicated in the technical specification . The battery charger and all its components should be housed inside the main fire pump pane The Scope of works also includes LT power control cabling including the GI ladder type cable tray necessary MS supports.etc complete in all respects as per technical specification."

1

-

-

... More
od143301/2021_2022 : UPS AND ACCESSORIES Supply , Installation, Testing and Commissioning of 5 kVA, single phase input, single Phase output, true on-line UPS system with 15 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . Refer technical specification and drawing for details. Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch System efficiency >90% Auto temperature compensation

1

-

-

... More
od143350/2021_2022 : 315KVA 11KV/0.433KV UNITISED SUBSTATION Design, fabrication,Supply, installation, testing and commissioning of indoor type Unitized Substation enclosure consisting of 11 KV, 630A, 26.3kA for 3 sec VCB with fully encapsulated vacuum interrupter panel , 315 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP23 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works etc. complete as per single line diagram technical specification. HT Compartment 11KV, 21kA , 630A LBS with earth switch 630 Amp continously rated Cu busbar Self powered microprocessor based three over current and one earth fault relay with protection CT's - 1 set Master trip relay and all accessories complete as required. 110V DC powerpack - 1 set Provision for padlocking for open, close, earth and test position Transformer Compartment 315 kVA, 11kV/433V 3 Ph, 50Hz, dry type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 100/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay in HT/LT panel as per SLD "LV Chamber Suitable for termination of LT cable. "

1

-

-

... More
CABLES AND CABLING

-

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

40

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

70

-

-

... More
10.3.4 : Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

1

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

1

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

2

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

82

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

220

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

40

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

210

-

-

... More
7.2.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

220

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

40

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

150

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

9

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

5

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

5

-

-

... More
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

5

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

160

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

57

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

5

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

874

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

293

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

25

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

100

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

40

-

-

... More
14.14.2 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia

30

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

45

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

45

-

-

... More
4.6.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness

20

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

10

-

-

... More
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

2

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

8

-

-

... More
9.1.13 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 95 sq. mm (38mm)

8

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

8

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

4

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

2

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

4

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

10

-

-

... More
od137201/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3C 95 Sq.mm Al

44

-

-

... More
od137202/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 120 Sq.mm Al

145

-

-

... More
od137203/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 185 Sq.mm Al

593

-

-

... More
od137204/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 300 Sq.mm Al

110

-

-

... More
od137205/2021_2022 : Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date. 3C X 300sq.mm.

132

-

-

... More
od137287/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 6 Sq.mm cU

203

-

-

... More
od137289/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 10 Sq.mm Al

33

-

-

... More
od137290/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3C 4 Sq.mm cU

154

-

-

... More
od137291/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 4 Sq.mm cU

165

-

-

... More
od137292/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 2.5 Sq.mm cU

165

-

-

... More
od137293/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 4 Sq.mm cU

277

-

-

... More
od137294/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3c 10 Sq.mm Al

44

-

-

... More
od137295/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 10 Sq.mm Al

11

-

-

... More
od137296/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 16 Sq.mm Al

50

-

-

... More
od137314/2021_2022 : Supply of 4C 35 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

374

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

18

-

-

... More
od138079/2021_2022 : Supplying and making end termination with brass doublr compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2C 6 Sq.mmCu

14

-

-

... More
od138080/2021_2022 : Supplying and making end termination with brass doublr compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C 4 Sq.mmCu

22

-

-

... More
od138081/2021_2022 : Supplying and making end termination with brass doublr compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3C 4 Sq mm Cu

14

-

-

... More
od138082/2021_2022 : Supplying and making end termination with brass doublr compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2C 4sqmm Cu

6

-

-

... More
od138083/2021_2022 : Supplying and making end termination with brass doublr compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C 2.5 Sq.mm Cu<br

30

-

-

... More
od138209/2021_2022 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required

300

-

-

... More
od138210/2021_2022 : Providing fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.

1

-

-

... More
od142304/2021_2022 : Fabrication, supply and installation of following size of ladder type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and painting etc as required 600MM WIDTH X 75 MM DEPTH X 2 MM THICK

10

-

-

... More
od142305/2021_2022 : Fabrication, supply and installation of following size of ladder type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and painting etc as required 450MM WIDTH X 75 MM DEPTH X 2 MM THICK

20

-

-

... More
od142306/2021_2022 : Fabrication, supply and installation of following size of ladder type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and painting etc as required 300MM WIDTH X 75 MM DEPTH X 2 MM THICK

30

-

-

... More
od142307/2021_2022 : Fabrication, supply and installation of following size of ladder type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and painting etc as required 150 MM WIDTH X 75 MM DEPTH X 2 MM THICK

20

-

-

... More
od142396/2021_2022 : Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required Above 120 sq. mm and upto 400 sq. mm

22

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

156

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

15

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

85

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

1247

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

708

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

581

-

-

... More
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

60

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

2

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

2

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

2

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

2

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

1

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

75

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

50

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

50

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

11

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

25

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

1

-

-

... More
od141574/2021_2022 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

29

-

-

... More
od142397/2021_2022 : Supply fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

6

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

9

-

-

... More
MCBs AND MCB DISTRIBUTION BOARDS

-

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

4

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

114

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

12

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

30

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

4

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

2

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

3

-

-

... More
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
od142921/2021_2022 : Supply, Installation, Testing Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete. ( Make: Enclosure- Siemens 8GB32100RC0X) or equivalent approved make)

4

-

-

... More
od142922/2021_2022 : Supply, Installation, Testing Commissioning of 40A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete. ( Make: Enclosure- Siemens 8GB32100RC0X) or equivalent approved make)

2

-

-

... More
od142923/2021_2022 : Supply, Installation, Testing Commissioning of 32A DP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete. ( Make: Enclosure- Siemens 8GB32100RC0X) or equivalent approved make) S F 32A DP isolator

2

-

-

... More
od142924/2021_2022 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40A to 63A ,SP D CURVE

1

-

-

... More
od142925/2021_2022 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6A to 32A ,SP D CURVE

42

-

-

... More
od142926/2021_2022 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40 A to 63A TP MCB, C-CURVE

10

-

-

... More
od142927/2021_2022 : upply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required. 4 pole 40 amps. (415 Volts),100mA sensitivity.

2

-

-

... More
od142928/2021_2022 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required. 4 pole 63 amps. (415 Volts),100mA sensitivity.

2

-

-

... More
od142929/2021_2022 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required. 4 pole 25 amps. (415 Volts),30mA sensitivity.

4

-

-

... More
od142930/2021_2022 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required. 2 pole 25 amps. (230 Volts),30mA sensitivity.

2

-

-

... More
od142931/2021_2022 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125Amp,16KA,FPMCCB

2

-

-

... More
od142932/2021_2022 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 160Amp,16KA,FPMCCB

1

-

-

... More
od142984/2021_2022 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 8 way double door horizontal type SPN DB

4

-

-

... More
od142985/2021_2022 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 12 way double door horizontal type SPN DB

1

-

-

... More
od142986/2021_2022 : Supply, installation commissioning of programmable recess/surface mounted PIR occupancy sensor with in built day light sensor with passive photocell. The sensor shall have adjustable off delay timer, sensitivity level adjustment etc prewired complete with all required accessories. Make: Honeywell K5017 or equivalent approved make 6m dia range at 2.5m mounting height. Make: Honeywell K5017 or equivalent approved make

5

-

-

... More
od142987/2021_2022 : Supply, Installation, Testing Commissioning of 32A DP isolator in weather proof enclosure on surface including all the mounting accessories, internal wiring etc as required complete. (Make Enclosure:Hensel KV PC 8104 or equivalent approved make)

2

-

-

... More
od142988/2021_2022 : Supply, Installation, Testing Commissioning of 32A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete. ( Make: Enclosure- Siemens 8GB32100RC0X) or equivalent approved make)

6

-

-

... More
od142989/2021_2022 : Supply, Installation, Testing Commissioning of 63A FP isolator in weather proof enclosure on surface including all the mounting accessories, internal wiring etc as required complete.

4

-

-

... More
od143441/2021_2022 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)

5

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

90

-

-

... More
1.45 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

11

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

251

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

11

-

-

... More
od142433/2021_2022 : Supply of 450 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.(Make: CG Vortex air circulator 450mm or equivalent approved make).

1

-

-

... More
od142434/2021_2022 : Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

11

-

-

... More
od142435/2021_2022 : Supply of LED surface mounted down light made of die cast aluminium with corrosion resistance powder coating, along with driver,surge protector, maximum system wattage of 10 Watts,IP 54,colour temperature as directed by engineer incharge with lumen output of lamp greater than 1000 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: LEDS COSMOS LED 669 or equivalent approved make)

25

-

-

... More
od142436/2021_2022 : Supply of LED recess mounted down light made of die cast aluminium, along with driver,surge protection, maximum system wattage of 15Watts, CCT- 3000K with lumen output of lamp greater than 1000 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: Wipro LD90-191-XXX-65-XX or equivalent approved makes)

107

-

-

... More
od142437/2021_2022 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate Diffuseralong with driver, maximum system wattage of 10Watts,lumen output of lamp greater than 1000, power factor >= 0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Wipro LL20-111-XXX-65-NE or equivalent approved makes

8

-

-

... More
od142438/2021_2022 : Supply of industrial surface mounted LED batten and lamp with Poly Carbonate Body and PolyCarbonate Diffuser, along with driver , surge protector, with maximum system wattage of 20 Watts,lumen output of lamp greater than 2000 lumen, rated life of L70 @ 25,000 hours,power factor >= 0.9, system efficacy greater than 100lumen/watt, and including all necessary accessories as required complete.Make:- Cat No: Crompton IGP131LT-8-16 housing+ 1nos of LTT8-20 LED or Wipro Capsule WIO831208G1 or LT AMIOT A02057ID00 or equivalent approved make

26

-

-

... More
od142439/2021_2022 : Supply of indoor surface mounted LED Batten with Polycarbonate Diffuser ,along with driver, with a maximum system wattage of 20 Watts ,lumen output greater than 2000 lumen, power factor >= 0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100 lumen/watt, and including all the necessary accessories as required complete.Make:- Cat No: LT Wand WO1857S000 or Wipro LL20-221-XXX-65AL1 or equivalent approved make

31

-

-

... More
od142449/2021_2022 : Installation, testing and commissioning of Wall fan, including wiring the down rods of standard length with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

1

-

-

... More
od142450/2021_2022 : Installation, testing and commissioning of High bay/LED/ T5 FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required.

31

-

-

... More
od142451/2021_2022 : Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor as required.

107

-

-

... More
od142452/2021_2022 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton Brisk Air or equivalant approved make)

9

-

-

... More
od142613/2021_2022 : Supply of 450 mm sweep,900 rpm heavy duty exhaust fan in metal body with louvers working on 230 V AC supply complete with all accessories as required. (Almonard or equivalant approved make)

2

-

-

... More
EXTERNAL LIGHTING AND COVE LIGHTING

-

-

-

... More
od142614/2021_2022 : Supply, installation, testing and commissioning of 5m long Hot dipped GI pole painted with PU coat with built- in control box prewired, with double armpole suitable for mounting two LED luminaires with lamp , concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, provision for mounting RCBO/MCB in the control box as required and all other accessories . Along with LED Lamp with die cast Aluminium alloy housing and polycarbonate diffuser, inbuilt driver,system wattage maximum of 30 watts, System efficacy not less than 110 lumen per watt ,power factor >0.9, IP 65 compliant including all necessary accessories as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly.(Pole Make : unique poles UEGP005 or equivalent approved make. Luminairie Make:Wipro Skyline LR02-331-XXX-57-XX or CG freedom+ LSTS-30-CDL or LT Adornis min -SL A03557M000 or equivalent approved make)

16

-

-

... More
od142615/2021_2022 : Supply of LED IP54 wall bracket light made of die cast aluminium alloy with non corrosive SS fasteners, along with driver, maximum system wattage of 30Watts,lumen output of lamp greater than 800 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, with CCT -3000 K, and including all necessary accessories as required complete.Make:- Cat No: Klite NAVIRA MINI 4971

5

-

-

... More
od142616/2021_2022 : Supply of LED IP54 path finder light made of die cast aluminium alloy with non corrosive SS fasteners, along with driver, maximum system wattage of 9Watts,lumen output of lamp greater than 800 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, with CCT -3000 K, and including all necessary accessories as required complete.Make:- Cat No: Klite Focus Midi half frame no-5633

20

-

-

... More
od142617/2021_2022 : Supply of LED light suitable for outdoor lighting made of die cast aluminium, along with driver,maximum system wattage of 25 Watts, IP 66, with pf > 0.9lumen output of lamp greater than 2500 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt , with provision for,mounting or extension and including all necessary accessories as required complete.Make:- Cat No: LT ADORNIS A02557WX00 or Wipro skyline LR02-291-XXX-57-XX )

6

-

-

... More
od142618/2021_2022 : Supply, installation, testing and commissioning of 5m long Hot dipped GI pole painted with PU coat with built- in control box prewired, with pole suitable for mounting LED luminairie with lamp , concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, provision for mounting RCBO/MCB in the control box as required and all other accessories . Along with LED Lamp with die cast Aluminium alloy housing and polycarbonate diffuser, inbuilt driver,system wattage maximum of 30 watts, System efficacy not less than 110 lumen per watt ,power factor >0.9, IP 65 compliant including all necessary accessories as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly.(Pole Make : unique poles UEGP005 or equivalent approved make. Luminairie Make:Wipro Skyline LR02-331-XXX-57-XX or CG freedom+ LSTS-30-CDL or LT Adornis min -SL A03557M000 or equivalent approved make)

5

-

-

... More
od142619/2021_2022 : Supply, installation testing and commissioning of of LED bollards with not less than 500 mm in height. The LED lamp shall have a maximum system wattage of 10W.The body shall be powder coated extruded aluminium. Luminaries provided with LED driver suitable for operation on 240V, 50Hz single phase ac supply.The fixture shall have IP65 class protection shall be provided with all accessories and civil foundations.( Wipro LB12-131-XXX-65-08 or equivalent approved make)

14

-

-

... More
od142623/2021_2022 : Supply, installation,testing and commissioning of 12V, 12W /mtr 120LED/mtr 400mA LED IP 67and CRI 90-95, rated life of L70 @ 50,000 hours with channel casing and acrylic cover complete with all necessary accessories like driver and all mounting arrangements like profile with PMMA Diffuser to terminate to a point wiring out. (Make : yyz or any other equivalent approved make)

60

-

-

... More
od142624/2021_2022 : Supply, installation,testing and commissioning of 12V, 12W/mtr 120LED/mtr 400mA LED strip light suitable for cove lighting with color temperature of 27K to 6K ,IP 20 and CRI 90-95, rated life of L70 @ 50,000 hours with channel casing and acrylic cover complete with all necessary accessories like driver and all mounting arrangements like profile with PMMA Diffuser to terminate to a point wiring out. (Make : Wipro Formz LED or any other equivalent approved make)

60

-

-

... More
LIGHT MANAGEMENT SYSTEM

-

-

-

... More
od142625/2021_2022 : Supply, erection, testing and commissioning of 4- channel dimming module with high inrush relays rated at 16 A per channel. The outputs should be able to control loads including 0/1-10 V DSI, DALI broadcast and PWM . The Ballast controller should have an intutive LED segment display and push buttons for monitoring, manual and control purposes "The Scope of Work also includes necessary control wiring, supply and installation of IR Remote control and modular panel (4 Button Keypad + Raise + Lower +ON/OFF) along with frame and power supply unit. "

2

-

-

... More
od142626/2021_2022 : Supply and installation of of LED recess mounted down light made of die cast aluminium, maximum system wattage of 20 Watts, along with 1-10 V analog dimmable driver ,lumen output of lamp greater than 1800 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, CCT - 3000K system efficacy greater than 100 lumen/watt and including all necessary accessories including control wiring as required complete .Make:- Cat No: LT IO1830D040 INTENSO PRECISE or equivalent approved make

48

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

12

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

3

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

100

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

207

-

-

... More
od142367/2021_2022 : Providing and fixing 3.15mm (10SWG) copper wire on surface or in recess for connections etc. as required.

400

-

-

... More
od142377/2021_2022 : Supplying and laying 3.15mm Cu (10 SWG) Copper wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt spring washer spaced at 50mm)

35

-

-

... More
od142380/2021_2022 : Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt spring washer spaced at 50mm)

78

-

-

... More
od142387/2021_2022 : Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt spring washer spaced at 50mm)

50

-

-

... More
od142388/2021_2022 : Providing and fixing 50 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.

127

-

-

... More
od142390/2021_2022 : Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required.

10

-

-

... More
od142391/2021_2022 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt spring washer spaced at 50mm) 4mm GI (8 SWG)

400

-

-

... More
od142392/2021_2022 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 4mm GI (8 SWG)

175

-

-

... More
od142628/2021_2022 : Supply and fixing of First aid box

1

-

-

... More
od142630/2021_2022 : Supply and providing ISI marked electrical 1.1 kV grade anti-skid rubber mat as per IS:15652.for the following sizes. 2mx1mx2mm thick

3

-

-

... More
od142631/2021_2022 : Supply providing ISI plate earthing as per IS 3043 with 1200x1200x12.5mm GI / CI earth plate with 20mm dia B class GI pipe for watering, 50x6mm GI strip welded to the plate, GI funnel with weld mesh, fixing GI strip of size 50x6mm with min. length of 20cm clamped with 50x5mm GI flat using 12x10mm GI bolt nut at top of the GI pipe as test joint, filling around the GI pipe at a radius of 15cm with a homogeneous mixture of charcoal, river sand upto a height of 2.5 meter from the bottom, filling the rest of the portion with excavated soil including watering ramming providing brick work (20cm) masonary at top in 1:6 cement mortar, plastering the inside top of the manhole with 12mm thick 1:6 cement mortar and providing gully trap with 450x450x10mm CI covering at the top.

8

-

-

... More
od142632/2021_2022 : Supply and fixing single line diagram, schematic diagrams etc. of A0 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

1

-

-

... More
od142633/2021_2022 : Supplying of Rubber hand gloves suitable for 11 KV.

1

-

-

... More
od142634/2021_2022 : Supply and fixing anodised aluminum glass framed shock treatment chart

1

-

-

... More
od142640/2021_2022 : Supply and providing ISI marked electrical 1.1 kV grade anti-skid rubber mat as per IS:15652.for the following sizes. 2mx1mx2.5mm thick

1

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
od142995/2021_2022 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

280.06

-

-

... More
od143009/2021_2022 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

170.5

-

-

... More
od143030/2021_2022 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 30 X 3 GI strip

10

-

-

... More
od143139/2021_2022 : Providing and laying hot dipped galvanized steel tape 30 mm X3 mm from earth electrode directly in ground as required.

194.04

-

-

... More
LIAISIONING CHARGES

-

-

-

... More
od143580/2021_2022 : LIASONING CHARGE

1

-

-

... More
HVAC EQUIPMENTS

-

-

-

... More
od136653/2021_2022 : Supply, Installation ,testing and commissioining of 36 HP minimum capacities of Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with multiple compressors, with variable speed inverter driven compressor as per specifications complete with suitable capacity drive motors, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, structural supports, high-low pressure cut off, with ODU vibration isolators, suitable for 3 phase, 415 V, 50Hz supply, starter panel, power wiring from starter panel,central controller, along with associated accessories for controlling entire VRF system along with power consumption monitoring of each individual indoor units with PDI, wattmeter as required along with suitable interconnecting control cabling between IDUs,ODUs and central controller ,Power wiring with necessary supports , necessary power control panel, along with associated accessories, structural supports /RCC/ cement concrete foundation,Vibration isolator etc. complete in all respects as per the technical specifications. (single feeder power source will be provided for 36 HP outdoor units by client )

2

-

-

... More
od136750/2021_2022 : Supply,Installation , testing and commissioning of 13TR minimum capacity ceiling suspended indoor ductable units with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan, as per specifications complete with power wiring, suitable capacity drive motor, electrical controller, temperature controller with digital display, control wiring, complete with necessary vibration isolators, CPVC drain pipe connections with 9mm thick round nitrile rubber insulation finished with factory laminated 7 mils woven fibre glass clothincluding U-trap along with necessary elbows, fittings etc., power/control cabling from power supply, etc complete in all respects as per the technical specifications.

4

-

-

... More
od136752/2021_2022 : Supply,Installation ,testing commissioning of 2.0TR (minimum capacity) VRF compatible Hi wall Split air conditioning unit complete with suitable capacity drive motor, control cabling(indoor to outdoor),thermostat wiring,drain piping,, out door vibration isolators, cordless remote etc complete as required. suitable for single phase 230 V supply and with suitable stabilizer etc complete as required.

2

-

-

... More
od136779/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/4") 44.5 mm

3

-

-

... More
od136780/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 5/8") 41.275 mm

3

-

-

... More
od136781/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/2") 38.1 mm

3

-

-

... More
od136782/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/8") 34.925 mm

3

-

-

... More
od136783/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/4") 31.75 mm

3

-

-

... More
od136784/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/8") 28.575 mm

72

-

-

... More
od136785/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 7/8") 22.225 mm

3

-

-

... More
od136787/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/4") 19.05 mm

3

-

-

... More
od136789/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 5/8") 15.875 mm

40

-

-

... More
od136790/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1/2") 12.7 mm

47

-

-

... More
od136791/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Soft Copper Pipe 20Guage with 13mm thick Insulation ( 3/8") 9.525 mm

15

-

-

... More
od136792/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with factory laminated 7mils and insulation shall have antimicrobial properties, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated. Soft Copper Pipe 20Guage with 13mm thick Insulation ( 1/4") 6.35 mm

3

-

-

... More
od136796/2021_2022 : Supply, Installation testing and commissioning of minimum 2.0 TR capacity Hi inverter wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor,outdoor unit and hi wall units for single phase 230 V supply minimum 3star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation ,suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19mm thick closed cell elastomeric insulation as per specification interconnecting indoor outdoor units with required pipe fittings and accessories like Bends, Tees, reducers, supports finished with factory laminated 7 mils glass cloth covering,necessary power/control cabling, suitably supported on trays/ split clamps etc., CPVC condensate drain pipe 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 12mm thick closed cell elastomeric insulation finished with factory laminated 7 mils galss cloth as per specification required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported on trays, clamps etc first charge refrigerant gas R410A/R407C, cordless remote etc complete as required, complete as required as per specification/ISHRAE standards.

2

-

-

... More
od136797/2021_2022 : Supply, installation, testing and commissioning of CPVC drain pipe of suitable dia connecting the drain pan of the indoor units with necessary U-traps, elbows, fittings etc. to nearest drain point, with 9 mm thick closed cell elastomeric insulation finished with factory laminated 7mils woven fibre glass cloth insulation shall have antimicrobial properties etc. complete in all respects as per the technical specifications.

100

-

-

... More
Air Dirtibution System

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

185

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

438

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

10

-

-

... More
DSR 16.23.2 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.: 25 mm thick

633

-

-

... More
od138041/2021_2022 : Supply, Installation, testing and commissioning of Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1 with antimicrobial properties. ,having density of 140 kg/m3 ,fixing of insulation using OEM recommended fixing details ,supports and adhesive, tapes etc. and with fire resistance meeting as per BS 476 Part 6 7 complete in all respects as per the technical specifications.

159

-

-

... More
od138046/2021_2022 : Supply & fixing of Acoustic Insulation of AHU Rooms using open cell processed nitrile rubber having a density of 140-180 Kg/m3 and thickness of 25 mm with anti-microbial protection with suitable frame works etc. complete in all respects as required by the technical specifications.

270

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

8

-

-

... More
DSR 16.16 Supplying fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

8

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

1

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

6

-

-

... More
od138585/2021_2022 : Supply, Installation , testing and commissioning of Aluminium Extruded Fresh air louvers with fresh air damper, bird screen etc. complete in all respects as per the technical specifications.

1

-

-

... More
od138586/2021_2022 : Supply , Installation, testing and commissioning of Inline cabinet fans (duct mounted) of 400 CFM - 15 MM OF WG with suitable blower, 3 phase/single phase , direct driven motor of following capacity for exhaust, with starter/starter panel and required power wiring ,other accessories complete in all respects as per the technical specifications

2

-

-

... More
od138587/2021_2022 : Supply , Installation, testing and commissioning of Inline cabinet fans (duct mounted) of 100 CFM - 15 MM OF WG with suitable blower, 3 phase/single phase , direct driven motor of following capacity for exhaust, with starter/ starter panel and required power wiring ,other accessories complete in all respects as per the technical specifications

2

-

-

... More
od139079/2021_2022 : Supply, Installation ,testing commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for air distribution Networks ,complete in all respects as per the technical specifications.

5

-

-

... More
FIRE HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
od137911/2021_2022 : Supply, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal, split casing, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal having rated flow of 2850 lpm at 70 m approximate head, conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC,suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required.(d) Suitable cement concrete foundation duly plastered along with anti vibration pads/mounts.

2

-

-

... More
od137917/2021_2022 : Supply, Installation, Testing and Commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification.(a) Horizontal, split casing, centrifugal type pump of cast iron body & bronze impeller with stainless steelshaft, mechanical seal having rated flow 2850 lpm at 70m head, conforming to IS 1520.(b) Suitable HP, suitable RPM water cooled radiator type diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,12v 180AH Battery and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity for 8 hour operation) with level indicator, By-pass line, piping from diesel tank to engine, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads/ mounts. (e) Diesel engine control panel

1

-

-

... More
od137919/2021_2022 : Supply, Installation, Testing and Commissioning of electric driven pressurisation pump (Jockey Pump) suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal having rated flow of 180 lpm at 70m head, conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC, suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation.

2

-

-

... More
od137925/2021_2022 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/sq.cm ) range, 3/8" BSP bottom entry, 100 mm dial weather proof with stainless steel internals including fittings, ball valve of suitable size etc. complete as required as per technical specification.

5

-

-

... More
od137926/2021_2022 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection with IP rated enclosure, phosphor bronze bellows as sensing element, SPDT contact system with fittings, ball valve of suitable of suitable size etc. complete as required as per technical specification.

5

-

-

... More
od137929/2021_2022 : Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories and painting with synthetic enamel paint of approved shade as required as per technical specification.

1

-

-

... More
od138086/2021_2022 : Supply, Installation, Testing and Commissioning of 250 mm nominal dia MS (Heavy C Class) pipe IS:3589 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

15

-

-

... More
od137931/2021_2022 : Supply, Installation, Testing and Commissioning of 200 mm nominal dia MS (Heavy C Class) pipe IS:3589 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

17

-

-

... More
od137933/2021_2022 : Supply, Installation, Testing and Commissioning of 150 mm nominal dia MS (Heavy C Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

274

-

-

... More
od137934/2021_2022 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS (Heavy C Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

127

-

-

... More
od137935/2021_2022 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS (Heavy C Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

100

-

-

... More
od137938/2021_2022 : Supply, Installation, Testing and Commissioning of 65 mm nominal dia MS (Heavy C Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

46

-

-

... More
od137939/2021_2022 : Supply, Installation, Testing and Commissioning of 50 mm nominal dia MS (Heavy C Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

72

-

-

... More
od137940/2021_2022 : Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS (Heavy C Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

167

-

-

... More
od137942/2021_2022 : Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS (Heavy C Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

4

-

-

... More
od137943/2021_2022 : Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS (Heavy C Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of suitable primer & two coats of epoxy paint of suitable shade. The pipe shall be fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

198

-

-

... More
od137944/2021_2022 : Supply, laying, testing and commissioning of C class heavy duty MS pipe of 150 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc. complete as required as per the technical specification.

303

-

-

... More
od138470/2021_2022 : Supply, laying, testing and commissioning of C class heavy duty MS pipe of 100 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc. complete as required as per the technical specification.

2

-

-

... More
od138471/2021_2022 : Supply, laying, testing and commissioning of C class heavy duty MS pipe of 80 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc. complete as required as per the technical specification.

6

-

-

... More
od139081/2021_2022 : Supply, installation, testing and commissioning of wafer type dual plate non-return valve of 200 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required.

1

-

-

... More
od137947/2021_2022 : Supply, installation, testing and commissioning of wafer type dual plate non-return valve of 150 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required.

3

-

-

... More
od137948/2021_2022 : Supply, installation, testing and commissioning of wafer type dual plate non-return valve of 100 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required.

2

-

-

... More
od137949/2021_2022 : Supply, installation, testing and commissioning of wafer type dual plate non-return valve of 65 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required.

2

-

-

... More
od137950/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 250 mm diameter, PN 16, with Cast iron/Carbon steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

4

-

-

... More
od137951/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 200 mm diameter, PN 16, with Cast iron/Carbon steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

6

-

-

... More
od137952/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 150 mm diameter, PN 16, with Cast iron/Carbon steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

15

-

-

... More
od137953/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 100 mm diameter, PN 16, with Cast iron/Carbon steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

10

-

-

... More
od139979/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 80 mm diameter, PN 16, with Cast iron/Carbon steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

3

-

-

... More
od137954/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 65 mm diameter, PN 16, with Castiron/Carbon steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts,GI nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

4

-

-

... More
od137955/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 40 mm diameter, PN 16, with Cast iron/Carbon steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts,GI nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

3

-

-

... More
od137956/2021_2022 : Providing, installation, testing and commissioning of 200 mm dia Y strainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

3

-

-

... More
od137958/2021_2022 : Providing, installation, testing and commissioning of 80 mm dia Y strainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

2

-

-

... More
od137959/2021_2022 : Supply,installation, testing and commissioning of gun metal fire hydrant valve, single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,chain, GI nuts, bolts, gasket etc as per technical specification.

10

-

-

... More
od137960/2021_2022 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per technical specification.(a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipments on wall.(d) Connections from riser with 25 mm dia stop valve (gun metal) with pipe

5

-

-

... More
od137961/2021_2022 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

20

-

-

... More
od137962/2021_2022 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.

12

-

-

... More
od137963/2021_2022 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.

10

-

-

... More
od137964/2021_2022 : Supply, installation, testing and commissioning of 4-WAY FIRE BRIGADE inlet connection made of CI Body, 150mm dia. flanged inlet with 4 Nos. of inbuilt gun metal, NRV (Body type) with PVC Blank cap & Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.

3

-

-

... More
od137966/2021_2022 : Supply, installation, testing and commissioning of Gun metal Air release valve, 25 NB male threaded inlet, complete with all accessories as required as per the technical specification.

3

-

-

... More
od137967/2021_2022 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage pendant type sprinkler1/2 NPT, K -5.0, Chrome Finish with rosetter plate operating temperature at 68 degC complete as required as per the technical specification.

48

-

-

... More
od137968/2021_2022 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage upright type sprinkler 1/2 NPT, K -5.0, Chrome Finish operating temperature at 68 degC complete as required as per the technical specification.

102

-

-

... More
od137969/2021_2022 : Providing, fixing, testing & commissioning of UL listed sprinkler of the following type:Quick response, Extended coverage sprinkler, upright type sprinkler 1/2" NPT, K -11.2, Chrome Finish operating temperature at 68 deg. C. complete as required as per the technical specification.

51

-

-

... More
od137970/2021_2022 : Supply, installation, testing and commissioning of 1m unbraided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc as required as per technical specification.

44

-

-

... More
od137971/2021_2022 : Supply, installation, testing and commissioning of UL listed or FM approved flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The body of the flow switch shall be water proof with suitable IP class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 10Kg/cm2 complete with all accessories as required as per the technical specification.

3

-

-

... More
od137972/2021_2022 : Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc. complete as required as per the technical specification..

1

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od137910/2021_2022 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

10

-

-

... More
od137915/2021_2022 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.

5

-

-

... More
od138164/2021_2022 : Supply and installation of ISI marked (IS: 15683:2018) Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket and all the accessories as requiredand as per the technical specifications.

2

-

-

... More
FIRE DETECTION AND ALARM SYSTEM

-

-

-

... More
od137913/2021_2022 : Supply, installation, testing and commissioning of Addressable type Multi Detector (smoke & heat sensor) complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, interconnecting to loop cable, complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

129

-

-

... More
od137918/2021_2022 : Supply, installation, testing and commissioning of Addressable type Manual pull station complete with all accessories like base box having provision for cable or conduit coupling as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

10

-

-

... More
od137921/2021_2022 : Supply, installation, testing and commissioning of addressable type or conventional with addressable module wall sounder cum strobe for both audio and visual indication complete with all fixing accessories, base box etc. under false ceiling, roof, wall, etc, as required as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

10

-

-

... More
od137924/2021_2022 : Supply, installation, testing and commissioning of fault isolator module to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable, complete in all respect with necessary accessories as required as per the technical specification. The product shall be UL listed & FM Approved.

14

-

-

... More
od137927/2021_2022 : Supply, installation, testing and commissioning of 24V Power supply unit for hooters with battery backup. The status of the power supply unit must be monitored from the FACP and alarm shall be obtained if the power supply unit fails to operate, complete in all respect with necessary accessories as required asper the technical specification.

3

-

-

... More
od137928/2021_2022 : Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication of fire fighters including all necessary accessories complete as required as per the technical specification.

10

-

-

... More
od137930/2021_2022 : Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.

12

-

-

... More
od137932/2021_2022 : Supply, installation, testing and commissioning of public address and talk back system consisting of 10 zone public address cum talk back console with mike and selector, multiple channel talk back facility, power supply, battery charger, battery housing, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier, and suitable capacity battery (min 12V), etc. complete as required for meeting the technical specifications.

1

-

-

... More
od137936/2021_2022 : Supply, installation, testing and commissioning of EN/UL/FM/LPCB approved/ listed, microprocessor based 1 loop intelligent addressable main fire alarm panel, central processing unit with the loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, LCD display with touch screen or other keypad and events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to integrate with analog/digital voice evacuation system (PA-talkback system) and shall be complete with all necessary accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required as per the technical specification and shall have following facilities.a) Programming software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verificatione)Alpha/numerical display f) Provision to connect to PCs and external printers

1

-

-

... More
od137937/2021_2022 : Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring purpose and send the signal from a flow switch to the alarm panel for initiating alarm when flow occur, complete with all necessary accessories as required as per the technical specification. The product shall be UL listed & FM Approved.

3

-

-

... More
od139967/2021_2022 : Supply, installation, testing and commissioning of addressable control to automatically trigger on/off devices like jet fans, AHU, extract air fans etc in case of fire. The product must meet technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

4

-

-

... More
od137941/2021_2022 : Supply and laying of 2x 1.5 sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above /below ground, on wall surface or recess as required as per the technical specifications.

2090

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

48

-

-

... More
od138170/2021_2022 : Supply, installation, testing and commissioning of CO2/Clean agent linear heat detection system using trace tubes for panel flooding of electrical panels(the main distribution MV electrical panel) consisting of gas cylinders with weight calculated on the basis of volume of single largest compartment within the panel. UL listed trace tube of required design length, a cylinder of required capacity, also consisting of master control unit with digital display, load cell, discharge hooter/flashers, pressure gauges, pressure switches for low pressure/discharge indications & interlocks with fire alarm system of the premises & all accessoriesforcomplete functionality of system, complete as required as per the technical specification.

1

-

-

... More
SIGNAGES

-

-

-

... More
od137912/2021_2022 : Supply and installation of photo luminescent glow signage such as Fire Duct/Fire Lift/Hose reel/Fire Staircase/No smoking etc. of standard size (500*200 MM) as per conventional design/ color code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

12

-

-

... More
od137914/2021_2022 : Supply and installation of photoluminescent glow signage for FIRE ASSEMBLY POINT of standard size (500*200 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help ofscrews & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

2

-

-

... More
od137920/2021_2022 : Supply and installation of photoluminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws&double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

5

-

-

... More
od137923/2021_2022 : Supply and installation of photo luminescent glow signage such as Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help ofscrews & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

13

-

-

... More
od139852/2021_2022 : Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407. Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.

5

-

-

... More
ELEVATOR SYSTEM

-

-

-

... More
od136627/2021_2022 : Design, fabrication,supply, installation ,testing and commisioning of machine room less electric traction type, stainless steel 10 Pax (680 Kg) passenger elevator with suitable car size at site (including freight,insurance and all applicable taxes and duties; if any etc.) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, granite flooring,adequate structural steel supports ,as required for the safe operation of the equipment. LED type emergency light, intercom suitable for hook up to purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction,shaft wiring and lighting with accessories,braille bttons, audio announcement along with prerecorded message,LED light fixtures, ventilation fan, etc complete with all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all associated electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required.The traction motor of machine room less elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. having automatic centre/side opening stainless door with stainless steel handrails on rear side as applicable in accordance of following details:- 2 stop 2 opening and entrance exit at same side and suitable for travel height of 4.15 mtrs. (Shaft Size 1900mm x 2100mm) with door opening of 800 mm and 2100 mm height. The equipment should be BMS compatible. All fabrication and procedures shall confirm to relevant IS standards. and as per technical specifications

2

-

-

... More
CCTV

-

-

-

... More
od136545/2021_2022 : Supply, Installation, Testing and Commissioning of 4MP Indoor Dome PoE camera with 1/2.9 inch CMOS sensor, Varifocal lens - 3 to 10mm, IR range - 15m, H.265, ONVIF Profile S, Certifications - CE / EN / UL and FCC along with all accessories as required at site as per technical specification.

24

-

-

... More
od136551/2021_2022 : Supply, Installation, Testing and Commissioning of CCTV central control equipment with capacity of 32 cameras, RAID5 with 30 days of archiving (Contractor to provide storage and calculations to justify the record duration) - with required HDDs and all required hardware, including necessary cabling with all accessories required at site complete as per technical specification. The video recording will be at 15fps in minimum HD resolution.

1

-

-

... More
od136568/2021_2022 : Supply, Installation, testing and commissioning of 42" commercial display, 24/7, full HD, with HDMI and USB ports with all accessories required at site complete as per specification.

1

-

-

... More
Access Control System

-

-

-

... More
od136612/2021_2022 : Supply, installation, testing and commissioning of Biometric card reader along with all necessary accessories and cabling as required at site complete as per technical specification.

2

-

-

... More
od136637/2021_2022 : Supply, installation, testing and commissioning of Single door EM lock along with all necessary accessories and cabling as required at site complete as per technical specification.

2

-

-

... More
od136666/2021_2022 : Supply, installation, testing and commissioning of Exit push button along with all necessary accessories and cabling as required at site complete as per specification.

2

-

-

... More
od136670/2021_2022 : Supply, installation, testing and commissioning of Emergency door release along with all necessary accessories and cabling as required at site complete as per specification.

2

-

-

... More
EPABX

-

-

-

... More
od136681/2021_2022 : Supply, Installation, Testing and Commissioning of IP based EPABX with 1 PRI line and 8 analogue extensions along with operator console, 20 pair MDF with krone modules, and all required accessories and cabling, as required at site complete as per technical specification.

1

-

-

... More
od136683/2021_2022 : Supply, Installation, Testing and Commissioning of Analog telephone including all accessories as required at site as per technical specification.

7

-

-

... More
Structured cabling

-

-

-

... More
od136689/2021_2022 : Supply, Installation, Testing and Commissioning of U/UTP cable - Category 6A, 4 pair, 23 AWG solid copper conductor, 500 MHz, with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site as per technical specification.

2250

-

-

... More
od136690/2021_2022 : Supply, Fixing, Testing and commissioning of size - 25mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall / floor as required at site and making good the same in case of recessed conduit as required.

1000

-

-

... More
od136694/2021_2022 : Supply, installation, testing and commissioning of 27U Network Rack along with all necessary hardware and accessories, etc. required at site complete as per technical specification.

1

-

-

... More
od136695/2021_2022 : Supply ,Installation, testing and commissioning of UTP Patch Cords, Category 6A - 2M along with all accessories required as per technical specification

52

-

-

... More
od136696/2021_2022 : Supply, Installation, Testing and Commissioning of Metal backbox along with all accessories required at site complete as per technical specification.

20

-

-

... More
od136697/2021_2022 : Supply, Installation, Testing and Commissioning of Single Shuttered Face Plate along with all accessories required at site complete as per technical specification.

14

-

-

... More
od136698/2021_2022 : Supply, Installation, Testing and Commissioning of Dual Shuttered Face Plate along with all accessories required at site complete as per technical specification.

6

-

-

... More
od136699/2021_2022 : Supply, Installation, Testing and Commissioning of CAT6A information Outlet, RJ 45 with all accessories required at site including termination complete as per technical specification

26

-

-

... More
od136700/2021_2022 : Supply, Installation, Testing and Commissioning of 50 port fully loaded voice panels with all accessories required at site complete as per technical specification.

1

-

-

... More
od136701/2021_2022 : Supply, Installation, Testing and Commissioning of CAT6A 24 port patch panel with shutter fully loaded, with all accessories required at site complete as per technical specification.

3

-

-

... More
Active Components

-

-

-

... More
od136717/2021_2022 : Supply, Installation, testing and commissioning of 24 port switch 10/100/1000Base-TX ports with 2 x 10G SFP+ ports with all accessories required at site complete as per technical specification.

1

-

-

... More
od136718/2021_2022 : Supply, Installation, testing and commissioning of 24 port PoE+ switch 10/100/1000Base-TX ports with 2 x 1G SFP ports with all accessories required at site complete as per technical specification.

1

-

-

... More
Internal and External Signages

-

-

-

... More
od137259/2021_2022 : Supply, Installation, testing and commissioning of External Fascia sign board with content "KSFDC" in single language (English) at specified locations (approximate installation height - 8m) made of PU Coated Channel Letters with 2.5 feet height and 4" thickness and width proportionate to be made with 1.2 mm aluminium sheet Letter front face is made up of 5mm solid acrylic 040 with vinyl and aluminium trim cap. The channel letters will be fixed either on the angle iron bend letters with screws or rivets of suitable size angle iron or directly screwed/Anchor bolted to the RCC using anchor fastener of suitable length as per the site conditions and as approved by engineer in charge. Letters should be lit using static white LED of approved make with required power supply. The system has to be wired to a outdoor light timer switch consisting of MCB, timers, contactors of suitable rating and all accessories including wiring as required etc. All metal parts are to be painted with 2 coats of epoxy primer and two coats of epoxy paint. The rate shall include cost and conveyance of all materials, structural supports (all the supports as required to install the signage from the available fascia / structural members), labour charges, scaffolding, lead, lift, etc complete as per technical specification.

2

-

-

... More
od137265/2021_2022 : Supply ,Installation, testing and commissioning of External fascia sign board with content "KSFDC" in single language( English) at specified locations made of 1.2 mm SS of depth 1" Letters with 1.5 feet height and width in proportion. The channel letters will be fixed either on the angle iron bend letters with screws or rivets of suitable size angle iron or directly screwed/Anchor bolted to the RCC using anchor fastener of suitable length as per the site conditions and as approved by engineer in charge. All metal parts are to be painted with 2 coats of epoxy primer and two coats of epoxy paint.The rate shall includes cost and conveyance of all materials, structural supports (all the supports as required to install the signage from the available fascia / structural members), labour charges, scaffolding, lead, lift, etc complete as per technical specification

1

-

-

... More
od137266/2021_2022 : Supply, Installation, testing and commissioning of one number of External led display screen capable of displaying letters and images with LAN communication, with flash memory capable of storing minimum 100 screens of data, RTC to invoke stored messages at desired date and time with programming software installed in a local PC allowing to configure the message to be displayed. The rate shall include cost and conveyance of all materials, structural supports (all the supports as required to install the signage from the available structural members), labour charges, scaffolding, lead, lift, etc as required at site complete as per technical specification.

15

-

-

... More
od137267/2021_2022 : Supply, installation, testing and commissioning of External backlit display box of depth 6" made out of 1.5" x 1.5" GI square tube framing covered with ACP sheet, uniformly illuminated with LED tube / strip, front fascia shall be UV digital printed flex fixed using hi-bond adhesive and 1" x 1" border frame painted with one coat epoxy primer and two coat enamel paint of approved colour along with all structural supports and accessories as required at site as per technical specifications.

19

-

-

... More
od137268/2021_2022 : Supply, Installation, Testing and Commissioning of direction and place identification retro-reflectorized sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2mm thick with area exceeding 0.9 sqm supported on mild steel angle iron post 75mm x 75mm x 6mm - 2 nos, firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete - 45cm x 45cm x 60cm below ground level as per technical specification.

4.5

-

-

... More
od137269/2021_2022 : Supply, Installation, Testing and Commissioning of Ceiling/Wall Mounted Signage of required size fabricated with Fascia with translucent/colored/block out/white Cast vinyl applied on Acrylic sheet of 3mm thickness - milky white with structural supports and all accessories required at site as per technical specifications. A uniform Border frame shall be provided to the profile with 2mm black powder coated aluminium sheet as approved by the Engineer in Charge

10

-

-

... More
od137270/2021_2022 : Supply, Installation, Testing and Commissioning of sticker type signage at site in proper line and level. The signage letters shall be made with premium quality vinyl sheet of approved colour, pasted / UV printed on self-adhesive film of approved colour, including all accessories required for proper completion of work as per technical specifications.

6

-

-

... More
od137271/2021_2022 : Supply, Installation, Testing and Commissioning of Fire Exit LED Sign of size not less than 1.5sqft with Rechargable Backup Battery (2+ Hours) with Aluminum Alloy Extruded Section with Epoxy polyester Powder Coating in Grey Colour. The content / artwork shall be etched in 10mm clear acrylic with precise matching of colour to Brilliant Green: IS Shade 221, with suitable arrangement for installation, cabling, etc in complete as required at site as per technical specification.

6

-

-

... More
od137272/2021_2022 : Supply, Installation, Testing and Commissioning of Edge Lit Sign of size 100mm x 100mm for Seat Numbers made up of 22 SWG CRCA Black powder coated housing and lit using LED of reputed make with row alphabets and numbers in Clear acrylic of thickness 5mm including all necessary cabling and other accessories as required as per the technical specifications.

48

-

-

... More
od137273/2021_2022 : Supply, Installation, Testing and Commissioning of LED Step Light made up of 22 SWG CRCA Black powder coated housing and lit using LED of approved make with row alphabets and numbers with clear acrylic sheet including SMPS and necessary cabling and other accessories as required as per the technical specifications.

160

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.