Kerala State Coastal Area Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Coastal Area Development Corporation Limited - KSCADC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date15 Dec 2023
Closing Date6 Jan 2024
Tender Amount₹ 16,13,15,102 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

1945.63

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

486.41

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

148.48

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

37.12

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

4164.22

-

-

... More
od252998/2023_2024 : Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in<br>depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth,for all leads and<br>lifts within the site as per site requirement and direction of engineer in charge, disposed earth to be<br>levelled and neatly dressed.<br>All kinds of soil

1681.6

-

-

... More
od253000/2023_2024 : Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in<br>depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth,for all leads and<br>lifts within the site as per site requirement and direction of engineer in charge, disposed earth to be<br>levelled and neatly dressed.<br>Ordinary rock

420.4

-

-

... More
od253001/2023_2024 : Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density ( proctor density)

1300

-

-

... More
Concrete Works

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

296.22

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

179.28

-

-

... More
od252980/2023_2024 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per<br>square metre on damp proof course after cleaning the surface with brushes and finally with a piece of<br>cloth lightly soaked in kerosene oil.

179.28

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

122.76

-

-

... More
RCC Works

-

-

-

... More
od252973/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).<br>All work upto plinth level

679.73

-

-

... More
od252974/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). <br>All work above plinth level upto floor V level

1612.57

-

-

... More
od252979/2023_2024 : Providing ,hoisting and fixing at all level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand conforming to IS383), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete as per direction of Engineer-in-charge but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.(Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting)

6.34

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

62930.25

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

222490.97

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

647.71

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

78.84

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

5223.6

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

5881.12

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

3369.4

-

-

... More
od252995/2023_2024 : Extra for Centering and shuttering for Circular Works - including strutting, etc. and removal of form for:<br>Foundations, footings, bases of columns, etc. for mass concrete

56.2

-

-

... More
od252996/2023_2024 : Extra for Centering and shuttering for Circular Worksincluding strutting, etc. and removal of form for:<br>Lintels, beams, plinth beams, girders bressumers and cantilevers

1882.6

-

-

... More
od252997/2023_2024 : Extra for circular shuttering - Centering and shuttering including strutting, etc. and removal of form for:<br>Columns, Pillars, Piers, Abutments, Posts and Struts

681.64

-

-

... More
od252999/2023_2024 : Extra for shuttering in circular work in Edges of slabs and breaks in floors and walls<br> Under 20 cm wide

843

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

920.19

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

1544.75

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

844.63

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

5441.52

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

1887.56

-

-

... More
Masonry Works

-

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

354.19

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

1038.87

-

-

... More
od252986/2023_2024 : Providing and laying autoclaved aerated cement blocks masonry with<br>100 mm thick AAC blocks in super structure above plinth level up to<br>floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate<br>includes providing and placing in position 2 Nos 6 mm dia M.S. bars at<br>every third course of masonry work.

101.09

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

510

-

-

... More
Joinery Works

-

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

2735.45

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

2580.2

-

-

... More
od252982/2023_2024 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With high performance glass panes of 6 mm thickness meeting GRIHA compliance of overall value "VLT > 34%, SHGC < 0.34.

362.72

-

-

... More
od252983/2023_2024 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With high performance glass panes of 6 mm thickness meeting GRIHA compliance of overall value "VLT > 42%, SHGC < 0.43.

153.54

-

-

... More
9.126.1 : Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710

8.28

-

-

... More
9.127.2 : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick

16.56

-

-

... More
od252993/2023_2024 : Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC/ Aluminium sliding window with necessary screws etc. complete.

204

-

-

... More
21.3.3 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness

8.4

-

-

... More
od252994/2023_2024 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):<br>With Toughened glass 12 mm thickness

89.6

-

-

... More
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

354

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

268

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

84

-

-

... More
50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop

125

-

-

... More
9.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete

89

-

-

... More
9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.

86

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

4.54

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

456

-

-

... More
od253002/2023_2024 : Providing and fixing hardwares for Handicaped door(Excluding door frame and panel).The shutter to be provided with cylindrical knob lock with rose diameter 75 mm and SS 304 grade matt finished kick plate of dimension 300 MM X 1020 MM X 0.9 MM including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing etc. complete as<br>directed by the Engineer-in-Charge at all levels

3

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

261.35

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

488.61

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

127.57

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

2

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m2 . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

280.4

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately

59.31

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge. The glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments).

14.85

-

-

... More
od253003/2023_2024 : Supplying And Fixing a pair of fire rated Solid SS Lever Handle and Mortise Lock case with Cylinder of approved size and quality for fire rated steel doors etc complete all works including all required fixtures as directed by Engineer in Charge.

56

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

110

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

143

-

-

... More
Steel Works

-

-

-

... More
10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

186

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

622.12

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

194.25

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

6996.39

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

4420.5

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

340.4

-

-

... More
10.19 : Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

340.4

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

5992.49

-

-

... More
13.50.4 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)

549.56

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

549.56

-

-

... More
Flooring Works

-

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

3931.21

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

329.71

-

-

... More
od252976/2023_2024 : Providing and laying Anti-skid Ceramic floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

412.28

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

483.22

-

-

... More
od252984/2023_2024 : Providing and fixing PVC tile edging to match the wall tiles and finishing as directed by the Engineer-in-Charge at all levels.

109.2

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

20.44

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

36

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

464.22

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

47.85

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

805.2

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

29.01

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

4.29

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

92

-

-

... More
8.9.1.2 : Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade

49.2

-

-

... More
Finishing Works

-

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

6647.49

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

15684.66

-

-

... More
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)

2237.04

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

750.95

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

18377

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

5926.35

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

18377

-

-

... More
Waterproofing and Miscellanious Works

-

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

412.28

-

-

... More
5.28 : Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints.

294

-

-

... More
21.7.1 : Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Anodised aluminium sheet 2.5 mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

693.6

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.

1756.69

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

96.78

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

17

-

-

... More
od252988/2023_2024 : PVC WEEP HOLES- Providing weep holes using 50mm dia. PVC pipes working pressure 6kg /sq.cm and covering ends with nylon mesh including cost of materials, conveyance, labour charges etc. complete.

400

-

-

... More
Tree planting

-

-

-

... More
30.2.57.1 : Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100)

100

-

-

... More
od252975/2023_2024 : Providing and stacking of Terminalia arjuna of height 150-165 cm. in big polybags of size 25<br>cm as per direction of the officer-in-charge.

10

-

-

... More
od252977/2023_2024 : Providing and stacking of Tectona grandis (Teak) of height 150-165 cm. in big polybags of<br>size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od252978/2023_2024 : Providing and stacking of Tamarindus indica (Imli) of height 120-150 cm. in big polybags of<br>size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od252981/2023_2024 : Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of<br>size 30 cm as per direction of the officer-in-charge.

10

-

-

... More
od252985/2023_2024 : Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of<br>size 30 cm as per direction of the officer-in-charge.

10

-

-

... More
od252987/2023_2024 : Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm. in Big HDPE Bag<br>as per direction of the officer-in-charge.

10

-

-

... More
od252989/2023_2024 : Providing and stacking of Peltophorum species of height 150-165 cm. in big poly bags of size<br>25 cm as per direction of the officer-in-charge.

10

-

-

... More
od252990/2023_2024 : Providing and stacking of Mimusops elengi (Maulsri) of height 150-165 cm. in big poly bag of<br>size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od252991/2023_2024 : Providing and stacking of Michelia champa (Golden Champa) of height 90-105 cm. in earthen<br>pots of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od252992/2023_2024 : Providing and stacking of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly<br>bag of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
APPENDIX B - ELECTRICAL WORKS 1.DG &amp; ACCESSORIES

-

-

-

... More
od253606/2023_2024 : 50 kVA DIESEL GENERATOR<br>"Supply, Installation, Testing and Commissioning of 50 kVA prime rated D.G Set with acoustic enclosure and Control panel including reverse power relay, protection and digital metering, controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including supply and installation of antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 50 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. <br>Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery."<br>

1

-

-

... More
LT PANEL BOARDS &amp; ACCESSORIES

-

-

-

... More
od253616/2023_2024 : MSB<br>Supply, Installation, Testing and Commissioning of LT Switch Board , cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI/ERDA certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4A Construction.<br>INCOMER 1<br>200A,FP 36kA MCCB with thermal based adjustable release with OL & SC protection - 1 Nos.<br>INCOMER 2<br>100A,FP 36kA MCCB with thermal based adjustable release with OL & SC protection - 1 Nos.<br>Buscoupler - 200A,FP 36kA MCCB with thermal based adjustable release with OL & SC protection - 1 Nos. <br>Instruments <br>4A, C curve SP MCB -2 sets<br>RYB indication lamp, LED type - 2 sets<br>(0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch - 2 nos<br>(0-100)A ammeter Acc. class 1 with 90 deg defl. scale - 3 no<br>(0-200)A ammeter Acc. class 1 with 90 deg defl. scale - 3 no<br>100/5A 15VA class 1 resin cast CT -1 set<br>200/5A 15VA class 1 resin cast CT -1 set<br>Digital multifunction meter with RS 485 Comunication Facility-2 nos<br>ON/OFF/TRIP indication lamp, LED type - 2 set<br>Busbar <br>200A TPN busbar chamber with Aluminium busbar.<br>Out goings<br>100A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL & SC protection - 3 Nos<br>63A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL & SC protection - 3 No<br>40A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL & SC protection - 2 No<br>25A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL & SC protection - 1 No<br>25A FP MCCB ISO - 1 No<br>SPD type-1<br>

1

-

-

... More
od253623/2023_2024 : Supply, installation, testing and commissioning of Outdoor type KSEB metering panel, including supply and fixing CT operated net TOD meter and consisting of 3 nos. of 200 A cutout with HRC fuse, neutral link, 200A FP,36 kA MCCB with shunt trip, earth leakage relay and CBCT,inter connections etc. as required, and necessary supports to be fabricated out of 14 SWG CRCA sheet with locable door with sealing facility having glass window for energymeter, sealing facility for KSEB, top canopy , weather proof enclosure(IP54)and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories as required including civil foundation .The panel shall be with all accessories as per drawing & specification.

1

-

-

... More
od253627/2023_2024 : <br>10 kVA UPS<br>Supply , Installation, Testing and Commissioning of 10 kVA, three phase input, three Phase output, true on-line UPS system with 30 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . <br>Fully digital controlled based on DSP<br>Power factor corrected from end > 0.9<br>Pure sine wave output.<br>Full time output voltage & frequency regulation<br>Auto regulation of battery end voltage<br>Intelligent interface with LED/LCD display<br>Static bypass switch / manual by pass switch<br>Auto temperature compensation<br>

1

-

-

... More
LT CABLES AND CABLING

-

-

-

... More
od253607/2023_2024 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.<br>150 mm width X 50 mm depth X 1.6 mm thickness<br>

20

-

-

... More
od253614/2023_2024 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.<br>300 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
od253618/2023_2024 : Supply of ISI marked HDPE pipes with following size of 10 kgf/cm2 conforming to as per IS 4984,1985 PE-100 including all fittings and specials such as tees, elbows, bends, reducers, end caps,complete so as to withstand the internal design pressure of 10 fkg/cm2 as directed by Engineer -in-Charge. <br>120 mm dia (OD)<br>

20

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

15

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

20

-

-

... More
14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia

30

-

-

... More
od253633/2023_2024 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required<br>40mm<br>

15

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

520

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

430

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

70

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

234

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

806

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

12

-

-

... More
od253654/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following 2C 4 sqmm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

28

-

-

... More
od253656/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following 3C 4 sqmm Cu<br> size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

16

-

-

... More
od253658/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.<br>4C 4 Sq.mm Cu

40

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

28

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

4

-

-

... More
od253663/2023_2024 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required.

200

-

-

... More
od253664/2023_2024 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required<br>300 MM WIDTH X 50 MM DEPTH X 2 MM THICK<br>

50

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

2

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

200

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

5

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

12

-

-

... More
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm

5

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

10

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

36

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

10

-

-

... More
od253665/2023_2024 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper<br>conductor cable conforming to IS 7098 (Part 1) amended upto date.<br>3C 2.5 Sq.mm Cu<br>

431

-

-

... More
od253666/2023_2024 : 35 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

179

-

-

... More
od253667/2023_2024 : 4 sqmm 4 core PVC/XLPE insulated armoured cable with copper conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE

510

-

-

... More
od253668/2023_2024 : 16 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

439

-

-

... More
od253669/2023_2024 : 4 sqmm 2 core PVC/XLPE insulated armoured cable withcopper conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE

263

-

-

... More
od253670/2023_2024 : 4 sqmm 3 core PVC/XLPE insulated armoured cable with copper conductors for working Voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE

105

-

-

... More
od253671/2023_2024 : 240 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

231

-

-

... More
od253672/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following 3C 2.5 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

24

-

-

... More
od253673/2023_2024 : 70 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

32

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

3251

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

4424

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

860

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

7985

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

4235

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

50

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

23

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

23

-

-

... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

17

-

-

... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

1

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

6

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

10

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

80

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

110

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

6

-

-

... More
od253652/2023_2024 : Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete. <br>

162

-

-

... More
od253653/2023_2024 : Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)<br>

162

-

-

... More
od253655/2023_2024 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.<br>Group C

299

-

-

... More
od253657/2023_2024 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

24

-

-

... More
od253659/2023_2024 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC<br>insulated copper conductor single core cable in existing PVC conduit,<br>with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS<br>PVC insulated copper conductor single core cable etc as required.<br>Group C

426

-

-

... More
od253660/2023_2024 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in<br>recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps<br>modular switch, connection etc. as required.

23

-

-

... More
MCBs AND MCB DISTRIBUTION BOARDS

-

-

-

... More
od253615/2023_2024 : Supply, Installation, Testing & Commissioning of 40A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete. <br>

6

-

-

... More
od253629/2023_2024 : Supply installation, testing and commissioning of out door (IP 54 ) Full automatic star delta starter for 15 HP, 3ph motor including auxiliary contactors, illuminated pushbuttons, provision for connecting external pressure switch, and remote operation, etc, all the necessary accessories as required complete. The starter enclosure shall be made of powder coated 1.6 mm CRCA sheet.<<br>

1

-

-

... More
od253634/2023_2024 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)<br>

2

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

14

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

321

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

26

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

20

-

-

... More
od253644/2023_2024 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required<br>4 pole 25 amps. (415 Volts),100mA sensitivity.<br>

4

-

-

... More
od253647/2023_2024 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required<br>2 pole 25 amps. (240 Volts), 100mA sensitivity-<br>

14

-

-

... More
od253648/2023_2024 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required<br>4 pole 25 amps. (415 Volts),30mA sensitivity.<br>

7

-

-

... More
od253650/2023_2024 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required<br>4 pole 40 amps. (415 Volts),100mA sensitivity.<br>

5

-

-

... More
od253651/2023_2024 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required<br>4 pole 63 amps. (415 Volts),100 mA sensitivity.

1

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

8

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

4

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

2

-

-

... More
90.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

2

-

-

... More
od253661/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required.<br><br>40A to 63A, TP,C-Curve MCB<br>

6

-

-

... More
od253662/2023_2024 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>100 Amp,25KA, FP MCCB<br>

2

-

-

... More
90.14.28.2 : S & F Motor starters of the following ratings Three Phase DOL starters for 0.25HP to 7.5 HP motor

7

-

-

... More
2.17 : Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

1

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

534

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

729

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

45

-

-

... More
od253622/2023_2024 : Installation, testing and commissioning of High bay/Mid bay//industrial/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 2.5 Sq.mm PVC insulated flexible copper conductor cable as required.<br>

12

-

-

... More
od253630/2023_2024 : Supply of IP66 streetlight luminaire made of die cast aluminium along with driver, system wattage of 30Watts,lumen output of luminaire greater than 3000 lumens, power factor > 0.9,rated life of L70 @ 50,000 hours system efficacy greater than 110 lumen/watt ,wth suitable driver and including all necessary accessories as required complete.(Make:- Cat No: Wipro LR02- 331-XXX-57-XX or other approved equivalent makes)<br>

12

-

-

... More
od253632/2023_2024 : Supply of 450mm sweep heavy duty exhaust fan indie cast aluminium with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: ALMONARD or equivalant approved make)<br>

2

-

-

... More
od253635/2023_2024 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Orient Smart Air Exhaust or equivalant approved make)<br>

44

-

-

... More
od253637/2023_2024 : Supply of 10w LED Bulkhead fitting with die cast aluminium housing, PC diffuser and IP66 Protection suitable for operation on 230V 50Hz AC, wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required. (Make:Philips edura or equivalent approved make)<br>

10

-

-

... More
od253638/2023_2024 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator)<br>

143

-

-

... More
od253640/2023_2024 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate diffuser, along with driver,with a maximum system wattage of maximum 22 Watts,lumen output of luminaire greater than 2000, power factor >0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Osram Luxsmart LED batten G2 or equivalent approved make<br>

212

-

-

... More
od253641/2023_2024 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate Diffuser ,along with driver,with a maximum system wattage of 10 Watts,lumen output of luminaire greater than 1000, power factor > 0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: OSRAM LUXSMART led BATTEN G2 or equivalent approved make<br>

54

-

-

... More
od253643/2023_2024 : Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector, with maximum system wattage of maximum 40 Watts,lumen output of luminaire greater than 4000 lumen, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO OPTIMA ll24<br>

260

-

-

... More
od253646/2023_2024 : Supply of surface mounted LED panel light fixture light made of CRCA Sheet with<br>corrosion resistance p[owder coating, along with driver, max system wattage of 36 Watts with lumen output of lamp not less than 3600 lumens, power factor > 0.9,<br>rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and<br>including all necessary accessories as required complete.Make:- Cat<br>No:Wipro:Immaculate LED or equivalent one)<br><br>

8

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
od253602/2023_2024 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)<br>4.00 mm GI conductor (8 SWG)<br>

400

-

-

... More
od253609/2023_2024 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)<br>3.15mm Cu (10 SWG)<br>

170

-

-

... More
od253612/2023_2024 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)<br>25mm X 3 mm Cu<br><br>

70

-

-

... More
od253619/2023_2024 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.<br>4.00 mm GI conductor (8 SWG)<br>

59

-

-

... More
od253624/2023_2024 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.<br>3.15mm Cu (10 SWG)<br>

400

-

-

... More
od253628/2023_2024 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.<br>25mm X 6mm GI <br>

110

-

-

... More
od253631/2023_2024 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.<br>25mm X 3 mm Cu<br>

60

-

-

... More
od253636/2023_2024 : Supplying and laying 25mm X 6mm GI <br> G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

600

-

-

... More
od253639/2023_2024 : Supply and fixing anodised aluminum glass framed shock treatment chart.<br>

1

-

-

... More
od253642/2023_2024 : Supply and fixing of First aid box <br>

1

-

-

... More
od253645/2023_2024 : Supply and providing ISI marked electrical 1.1 kV grade anti-skid rubber mat as per IS:5424.for the following 1mtr X 1mtr X2mm size<br>

3

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
od253649/2023_2024 : Earthing with C.I. earth pipe 3 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended uptodate)<br>

18

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
od253608/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3 <br>

375

-

-

... More
od253613/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3 <br>

500

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

320

-

-

... More
od253621/2023_2024 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip<br>

12

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
90.15.3.3 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters

12

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

12

-

-

... More
od253610/2023_2024 : ODP1<br>Supply, Installation, Testing and Commissioning of Outdoor Lighting Panel (ODP) cubicle type, totally enclosed, IP 65, pedestal mounted, free standing with top canopy, dust and vermin proof, water proof suitable for operation on 3 phase, 415 V, 50Hz AC supply with provision for fixing incoming & outgoing switches fabricated using 2mm thick CRCA sheet, powder coated, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc., The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) including following switchgears accessories for the LT Panel. The Panel shall be of form 4 construction<br>INCOMER<br>40 A, FP, 25kA, MCCB with adjustable thermal magnetic release with OL & SC protection - 1 No<br>BUSBARS<br>100 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy - 1 Set<br>INSTRUMENTS<br>Surge protection device -Type1+2<br>(0-500)V voltmeter Acc.class 1 with VSS- 1 No<br>(0-40)A ammeter Acc. class 1 with 90 deg defl. scale - 3Nos 4A, C curve SP MCB - 3 Nos.<br>RYB indication lamp, LED type - 1 Set<br>OUTGOINGS<br>25 A, FP RCCB (100mA)-6 Nos<br>25 A C Curve FP MCB-6 Nos. The rate for the foundation shall be measured with civil works

1

-

-

... More
STATUTORY CHARGES

-

-

-

... More
od253604/2023_2024 : STATUTORY CHARGES<br>

1

-

-

... More
SOLAR WORKS

-

-

-

... More
od253603/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for 2C 1.5sqmm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br>

2

-

-

... More
od253605/2023_2024 : Supply of 2C 1.5sqmm 1.1 kV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.<br>

135

-

-

... More
od253611/2023_2024 : Supplying and termination of UV Resistive MC4 Connectors suitable for terminating 4 Sq. mm copper cables(Male & Female Connectors). Y connector at Inverter end also shall be measured under this item.The item includes all necessary accessories tape etc as required complete as per techical specififcation. <br>

32

-

-

... More
od253617/2023_2024 : Supply and laying of Single core 4 Sq. mm Unarmoured copper Solar cables from Modules to String Combiner / Monitoring Box/inverter. The item includes all necessary accessories clamp, ties etc as required complete as per techical specififcation. <br>

200

-

-

... More
od253620/2023_2024 : Supply fabrication, erection of Mounting structures for solar panels with Hot dip galvanized GI rectangular Tubes. The Mounting structure should have 40mm GI angle section for routing 4 Sq. mm DC cables between Modules and Modules to cable trays, including necessary clamps, welding, nuts, bolts, etc. Mounting structure shall be fabricated for group of panels(4 Nos) as per technical specification. (Item shall be measured against number of panel)<br>

4

-

-

... More
od253625/2023_2024 : Supply, installation testing and commissioning of MONO PERC module solar photovoltaic panels of total of 6kWp rating meeting IEC 61215 (revised) / IS 14286 / IEC 61646 standards & IEC 61730-1 with minimum efficiency of 19.5% with all accessories as per the tender specifiation.

1

-

-

... More
od253626/2023_2024 : "Supply, Installation, Testing and Commissioning of Grid Tied solar string inverter of 6kVA rating , IP 66 rated, outdoor, three Phase output, true sinewave inverter system, with Maximum Power Point Tracker charge controller. Inverter should have MPPT with 1 string per MPPT. Minimum protection required shall be over voltage/surge, over load, short circuit and anti- islanding protection. Earthing shall be provided as per IEC standards. IGBT based true sine wave output. Unity Power factor(6kVA=6kW) . Accuracy of AC voltage control = +/-3%. Accuracy of AC frequency control = +/-1%. Frequency = 50Hz. Intelligent interface with LED/LCD display(Bluetooth/Wifi interface is also acceptable) . .Total Harmonic Distortion <3%”. The inverter should have all specification, protections, operational modes, etc as detailed in techinical specification. The inverter should have in-built Type Surge protection device on AC and DC side.The item includes all necessary accessories like supports, canopy, AC Isolation boxes(with energy meter), Junction boxes, Combiner boxes, DCDBs, cabling from AC Isolation boxes to inverter, connectors, etc as required complete as per technical specification.<br>"

1

-

-

... More
APPENDIX C - PLUMBING WORKS 1.SANITARY WORKS

-

-

-

... More
od253823/2023_2024 : Providing and fixing star white vitreous china under counter wash basin of approved<br>size &<br>make<br>including one CP brass pillar cock 15 mm NB with aerator including connecting pipes<br>with<br>all fittings 32 mm dia rubber<br>plugs 32 mm dia CP brass waste coupling, 32 mm dia CP brass<br>bottle trap,<br>15mm angle valve, etc.<br>complete as directed by the Engineer-in-charge at all<br>levels.(Models Cera<br>S2030103/ Hindware 1004900SW+ Cera F1015101/Hindware F280001CP or<br>equivalent with griha water conservation<br>arrangement as per the instructions of the engineer in<br>charge)

38

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

48

-

-

... More
od253824/2023_2024 : Providing and fixing white vitreous china flat back urinal with sensor<br> and<br>C.P.<br>brass spreaders with brass unions and G.I. clamps complete, including painting of fittings<br>and<br>brackets,<br>cutting and making good the walls and floors wherever required: Models Hindware 6002110 /<br>Cera S4010101<br>or equivalent with griha water conservation mechanism etc complete as directed by the<br>Engineer in charge<br>at all levels

12

-

-

... More
od253825/2023_2024 : Supplying and fixing approved quality white vitreous china urinal<br>division<br>plate<br>including cost and conveyance of all material, labour charge, lead, lift, etc. complete as<br>directed by<br>the<br>Engineer-in-Charge. Models- Cera S4090101/ Hindware 61001 or equivalent

12

-

-

... More
od253826/2023_2024 : Providing and fixing C.P. brass long body bib cock with griha water conservation<br>mechansim of approved quality conforming to IS standards and weighing not less than 690 gms. Models<br>Hindware F400002CP/ Jaquar FLR-CHR-5047NGE or equivalent<br>15 mm nominal bore

48

-

-

... More
18.16.2 : Providing and fixing brass stop cock of approved quality :20 mm nominal bore

6

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

38

-

-

... More
od253830/2023_2024 : Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade<br>floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete<br>as directed by the directed by the Engineer-in-Charge at all levels

6

-

-

... More
od253831/2023_2024 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries, etc complete as directed by the Engineer in charge at all levels. 75mm dia

16

-

-

... More
od253832/2023_2024 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame<br>with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour<br>charges, sundries etc complete as directed by the Engineer in charge at all levels. 110mm dia

9

-

-

... More
od253833/2023_2024 : Providing and fixing sink cock of approved quality conforming to IS 8931. Models Cera<br>F1015251/Hindware F330034 or equivalent with griha water conservation mechanism as approved by the<br>engineer in charge at all levels

2

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

2

-

-

... More
od253834/2023_2024 : Providing and fixing white vitreous china extended wall mounting water closet<br>of<br>approved shape and size including providing & fixing white vitreous china cistern with dual flush<br>fitting, of<br>flushing capacity 2 litre/4 litres , including seat cover,angle valve and cistern fittings, nuts bolts<br>and gasket etc complete<br>as directed by the engineer in charge at all levels. Models Cera<br>S1031111+B1020105+B1520102/ Hindware<br>20096 (P-15)+Cist.: 21056 or equivalent with griha water<br>conservation mechanism etc complete as directed<br>by the Engineer in charge at all levels.

46

-

-

... More
od253835/2023_2024 : Providing and fixing floor trap with cockroach trap (multi trap), exposed, SS304 grade<br>floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete<br>as directed by the directed by the Engineer-in-Charge at all levels

62

-

-

... More
od253836/2023_2024 : Providing and fixing sanitary fixtures for handicapped toilet including one wash<br>basin<br>, one number pillar cock with aerator & all other related fittings like CP brass bottle trap,CP brass<br>angle valve, CP brass waste coupling, etc, one number EWC & Cistern complete with fittings & seat cover,<br>one no. hinged rail & 4 nos. of grab rails 60cm etc, designed for people with special needs comes with as per<br>manufacturers specification including cutting and making good the walls and floors wherever required<br>as directed by Engineer-in-Charge. Hindware Matrix Set/Cera Cruse Set, Hindware F280001CP/Cera F1015101 or equivalent.

2

-

-

... More
od253837/2023_2024 : :Providing and fixing white vitreous china wall hung wash basin of approved<br>make<br>including one<br>CP<br>brass pillar cock with GRIHA water conservation mechanism including connecting pipes<br>with all fittings 32 mm dia<br>rubber plugs 32 mm<br>dia CP brass waste coupling ,complete including<br>CI/MS brackets duly painted,<br>nuts, washers, etc. complete,cost and conveyance of<br>all<br>materials<br>labour charges ,lead, lift<br>necessary wall cutting / chasing and making<br>good<br>the<br>walls,floors,slab,testing and commissioning<br>to the satisfaction of Engineer in charge at<br>all levels. Models Cera S2040105/Hindware 10054+Cera F1015101/Hindware F280001CP or equivalent as<br>instructed by the Engineer in charge

2

-

-

... More
od253838/2023_2024 : Providing and fixing CP Brass robe hook as per the instructions of the Engineer in<br>charge. Models Cera F5003108/ Hindware F880004CP or equivalent

48

-

-

... More
WATER SUPPLY

-

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

76

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

162

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

24

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

35

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

43

-

-

... More
od253827/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall<br>75 mm nominal dia pipes

52

-

-

... More
od253828/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall<br>62.5 mm nominal dia pipes

99

-

-

... More
od253829/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Internal work - Exposed on wall<br>100mm nominal dia<br><br>

6

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

10

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

10

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

15

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

15

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

15

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

5

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

15

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

2

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

6

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

20000

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
od253839/2023_2024 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone<br>aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 60 x 60 cm and 100 cm deep including C.I. cover 500 mm with frame (medium duty) : With bricks.Class designation 75

10

-

-

... More
od253840/2023_2024 : Supplying, fixing, testing and commissioning to the satisfaction of Engineer in charge<br>of PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and water tight C.I cover with<br>frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less<br>than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above<br>mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk<br>brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully<br>trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the<br>PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc<br>complete as per approved drawing and as directed by Engineer-in- Charge

5

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

17

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

5

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

10

-

-

... More
od253841/2023_2024 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80<br>mm dia

10

-

-

... More
19.30.2.1 : Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

12

-

-

... More
18.31.1.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass II

5

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

13

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

132

-

-

... More
od253842/2023_2024 : Supplying and fixing GM foot valve with all accessories including cost and conveyance<br>of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <br>40 mm

2

-

-

... More
od253843/2023_2024 : Supplying and fixing GM foot valve with all accessories including cost and conveyance<br>of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <br>50 mm

10

-

-

... More
od253844/2023_2024 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 65mm

5

-

-

... More
od253845/2023_2024 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 80mm

5

-

-

... More
od253846/2023_2024 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 80mm

3

-

-

... More
od253847/2023_2024 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 150mm

2

-

-

... More
od253848/2023_2024 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 100mm

5

-

-

... More
od253849/2023_2024 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 100mm

5

-

-

... More
od253850/2023_2024 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 65mm

5

-

-

... More
od253851/2023_2024 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 200mm

2

-

-

... More
od253852/2023_2024 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm 'Y' type strainer

6

-

-

... More
od253853/2023_2024 : Supply,Fixing & commissioning of a double acting air and vaccum release 20 mm Air release valve . The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar.<br>

12

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

213

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

422

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

59

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

20

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

20

-

-

... More
od253854/2023_2024 : SSupplying and fixing of electronic diaphragm type dosing pump suitable for pumping<br>chlorine solution including cost of valve, suction and delivery lines using heavy duty PVC tubes, HDPE<br>chlorine feed tank of 100 litres capacity etc. and complete with all accessories as directed by the Engineerin<br>-Charge.<br>Capacity : 6 lph @ 3.5 kg/cm2

1

-

-

... More
od253855/2023_2024 : Supplying and installing activated carbon filter of size 5 cum/hr with internally<br>and<br>externally epoxy coated, raw water distributor, filter water collecting system, pressure gauges at<br>inlet and<br>outlet, strainers, supporting structure, back wash arrangement, set of inlet and outlet valves, Vnotch<br>Board<br>etc and all other accessories .The rate shall include cost and conveyance of all materials,<br>labour etc.<br>complete and as directed by Engineer-in-Charge.

1

-

-

... More
od253856/2023_2024 : Supply and erection of dual media filter of size 0.6m dia x 1.2 m HOS, (approx.)<br>vertical<br>type pressure vessel, mild steel internally and externally epoxy coated, 6mm shell thickness,<br>6mm dish<br>thickness, flanged top and bottom, operating pressure of 3.5 Kg/cm2, complete with CI valves<br>and graded<br>pebble and sand as media, frontal piping, pressure gauges, strainers, supporting structure,<br>back wash<br>arrangement, etc and all other accessories .Flow rate 5m3/hr

1

-

-

... More
od253857/2023_2024 : >Supplying and fixing of centrifugal pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels<br>>Head 35m, Capacity-5 m3/hr

2

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

0.5

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.5

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.5

-

-

... More
od253858/2023_2024 : Supplying and fixing of submerssible pump, with CI construction, CI impeller complete with motor, base<br>plate, nuts, pressure guage and all accessories. and working with 415V, 3ph and 50 Hz<br>frequency including cost and conveyance of all materials,labour charges etc complete as directed by the<br>Engineer-in-Charge at all levels 10m3/hr:103Head

1

-

-

... More
od253859/2023_2024 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete<br>with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with<br>415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc<br>complete as directed by the Engineer in charge at all levels Capacity 250-110 lpm , Head - 24-36 m

4

-

-

... More
od253860/2023_2024 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:<br>300 mm dia R.C.C. pipe

10

-

-

... More
od253861/2023_2024 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:<br>150 mm dia R.C.C. pipe

10

-

-

... More
od253862/2023_2024 : Supplying and fixing GI threaded rod for fixing pipes to walls on slotted channels adequately spaced from the walls.The rate is inclusive of cost and conveyance of all materials,labour charges etc and as directed by the Engineer in charge at all levels.

56

-

-

... More
od253863/2023_2024 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 200 mm dia 6 Kgf/cm2

60

-

-

... More
od253864/2023_2024 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kgf/cm2 - Internal work- Exposed on wall

108

-

-

... More
od253865/2023_2024 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 160 mm dia 6 Kgf/cm2

370

-

-

... More
od253866/2023_2024 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110 mm dia 6 Kgf/cm2

132

-

-

... More
od253867/2023_2024 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/cm2

33

-

-

... More
od253868/2023_2024 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

30

-

-

... More
od253869/2023_2024 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

114

-

-

... More
od253870/2023_2024 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

13

-

-

... More
od253871/2023_2024 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

453

-

-

... More
od253872/2023_2024 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 kgf/cm2

136

-

-

... More
od253873/2023_2024 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110mm pipe 6 kgf/cm2

152

-

-

... More
APPENDIX D - FIRE PROTECTION WORKSFIRE HYDRANT SYSTEM

-

-

-

... More
od253983/2023_2024 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI ( 0 - 14 Kg ) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals, siphon tube and ball valve including fittings, etc. complete as required as per the technical specification.

1

-

-

... More
od253984/2023_2024 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required as per the technical specification.

1

-

-

... More
od253985/2023_2024 : Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 100 mm dia

225

-

-

... More
od253986/2023_2024 : Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 80 mm dia

7

-

-

... More
od253987/2023_2024 : Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including<br>fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. in ground at a depth of 1m including<br>excavation & providing cement concrete blocks as supports, anticorrosive wrapping coating 4 mm thick as<br>per IS10221, refilling the trench etc. of following sizes complete as required as per technical specification<br>100mm dia

4

-

-

... More
od253988/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of following sizes having PN 16 pressure rating complete with CI body, flanged end, GI bolts, nuts, washers etc. as required as per technical specification and confirming to API:594. 100 mm dia

2

-

-

... More
od253989/2023_2024 : Supply, installation, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 14846 of following sizes as required as per the technical specification. 100 mm dia

1

-

-

... More
od253990/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, EPDM/Nitrile rubber liner,O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification. 100 mm dia

6

-

-

... More
od253991/2023_2024 : Supply,installation,testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,Chain etc required as per the technical specification.

13

-

-

... More
od253992/2023_2024 : Supplying and fixing First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per the technical specification.<br><br>(a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585<br>(b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle.<br>(c) Drum and brackets for fixing the equipments on wall.<br>(d) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe

12

-

-

... More
od253993/2023_2024 : Supplying and fixing 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required as per the technical specification.

26

-

-

... More
od253994/2023_2024 : Supplying & fixing 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per the technical specification.

13

-

-

... More
od253995/2023_2024 : Supply, installation, testing and commissioning of Fire brigade collective breaching with 2 nos. of 100 mm flanged out let connection and built in check valves complete as required as per technical specification

1

-

-

... More
od253996/2023_2024 : Supply, installation, testing and commissioning of hose boxes (Hose cabinet) wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications. All Fire Stations/ Cabinets shall be clearly marked ‘FIRE’ with luminous signs.

13

-

-

... More
od253997/2023_2024 : Supply, installation, testing and commissioning of Air release valve 25 mm dia. complete as required as per the technical specification.

4

-

-

... More
od253998/2023_2024 : Supply, Installation, testing and commissioning of 100 mm dia Y strainer with CI body, 3 mm perforated SS screen, flanged end connection confirming to IS specifications complete with gaskets, seal and accssesories as required as per the technical specification.

1

-

-

... More
od253999/2023_2024 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: complete in all respect as required and as per the technical specification. Monoblock Pump rated for 450lpm, 40 m head C.I body, bronze impeller,SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation.M.S. fabricated common base plate, foundation bolts, anti vibration pads etc. as required. The cost shall include suitbale capacity DOL starter and one isolator near the pump complete with all necessary cabling to provide successful automatic operation of the pump.

1

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od253975/2023_2024 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark. complete as required as per the technical specification.

21

-

-

... More
od253978/2023_2024 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas. complete as required as per the technical specification.

2

-

-

... More
od253979/2023_2024 : Supply and installation of ISI marked Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

3

-

-

... More
SIGNAGE

-

-

-

... More
od253976/2023_2024 : Supply and installation of glow signage (photoluminescent) such as Fire Duct/Fire Lift/Staircase signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

27

-

-

... More
od253977/2023_2024 : Supply and installation of glow signage (photoluminescent)of FIRE ASSEMBLY POINT of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

1

-

-

... More
od253980/2023_2024 : Supply and installation of glow signage (photoluminescent) such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

22

-

-

... More
od253981/2023_2024 : Supply and installation of glow signage (photo luminescent) of FIRE ORDER of standard size (600*800 mm minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

12

-

-

... More
od253982/2023_2024 : Supply and installation of Fire Emergency Evacuation Plan (Color) Printed in Photo Paper of Size A2 sandwiched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification.The plan shall be prepared by the contractor as per NBC 2016 and inconformance with IS 9457,IS 12349 and IS 12407.

12

-

-

... More
APPENDIX E - SEPTIC TANK WORKS 1.Earth work

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

320.11

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

80.03

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

151.63

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

37.91

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

179.06

-

-

... More
Concrete work

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

24.38

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

21424.26

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

2984.74

-

-

... More
RCC work

-

-

-

... More
od254155/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note: - Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account).<br>All work upto plinth level<br>

65.01

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

0.41

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

6600

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

24.98

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

73.36

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

328.47

-

-

... More
Steel work

-

-

-

... More
od254156/2023_2024 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight<br>of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

4

-

-

... More
Finishing works

-

-

-

... More
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)

277.39

-

-

... More
Miscellaneous works

-

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

169.6

-

-

... More
od254157/2023_2024 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge<br>110mm OD(6 kg/cm2)<br>

30

-

-

... More
od254158/2023_2024 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

2

-

-

... More
APPENDIX F - SUMP & PUMP ROOM WORKS U G Sump-160M3

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

317.88

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

79.47

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

162.42

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

40.61

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

156.89

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

9.28

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

11010.88

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

28768.41

-

-

... More
od254178/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note: - Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account).<br>All work upto plinth level<br>

87.18

-

-

... More
od254179/2023_2024 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or<br>lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases,<br>slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse<br>sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1<br>Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix<br>cement concrete of M-25 grade conforming to IS 456 or IS 10262

0.91

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

17.04

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

410.6

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

70.13

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

36.5

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

109.5

-

-

... More
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)

497.9

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

395.7

-

-

... More
19.15.2 : Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design.With 20 mm diameter round bar

44

-

-

... More
od254181/2023_2024 : Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

4

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

0.3

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.3

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.3

-

-

... More
Pump Room

-

-

-

... More
od254176/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. <br>All work above plinth level upto floor V level

6.03

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

575.9

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

23.15

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

19.92

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

15.09

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

30.38

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

30.38

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

6.75

-

-

... More
od254177/2023_2024 : Providing and fixing steel (white power coated) crescent lock for uPVC /aluminum sliding window/ door with necessary screws etc. complete.

9

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

101.25

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

9

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

19.8

-

-

... More
13.50.4 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)

25.37

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

25.37

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

3

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

15.95

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

2.52

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

6.54

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

1.76

-

-

... More
od254180/2023_2024 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half thick solid block masonry.

11.97

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

121.44

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

36.47

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

58.19

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

157.91

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.

23.15

-

-

... More
APPENDIX G - ROAD & RETAINING WALL Road works and DR Wall

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

144

-

-

... More
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

36

-

-

... More
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site

510

-

-

... More
od254167/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). <br>All work upto plinth level

52.2

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

4176

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

32

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

80.78

-

-

... More
Paving Works

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

165

-

-

... More
od254164/2023_2024 : Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in<br>depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth,for all leads and<br>lifts within the site as per site requirement and direction of engineer in charge, disposed earth to be<br>levelled and neatly dressed.<br>All kinds of soil

253.6

-

-

... More
od254165/2023_2024 : Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in<br>depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth,for all leads and<br>lifts within the site as per site requirement and direction of engineer in charge, disposed earth to be<br>levelled and neatly dressed.<br>Ordinary rock

63.4

-

-

... More
od254166/2023_2024 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, with all lead and lift as per direction of site Engineer-in-charge.

1500

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

22

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

110

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

49.5

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

385

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

315.3

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

525.5

-

-

... More
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.

2102

-

-

... More
Elevator System

-

-

-

... More
od254864/2023_2024 : Design, fabrication, supply , Installation , testing and commissioning of machine room less electric traction type , Stainless steel 10 Pax passenger elevator(680 Kg) with suitable car size (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc. except GST ) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to purchaser's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, complete with all accessories including Automatic Rescue Device (with dry maintenance free sealed<br>batteries) in the event of power failure , shaft wiring and lighting with accessories,braille buttons,audio announcement along with<br>prerecorded message as approved by Engineer-in-Charge.The traction motor of the elevator shall be of gearless type and placed<br>inside the elevator shaft complete as per technical specification. Having automatic Centre/side opening SS door stainless steel car<br>enclosure provided with stainless steel handrails on Three sides, Granite flooring as applicable in accordance of following details:-4<br>stops & 4 openings and entrance & exit at same side and suitable for travel height of 12.3 mtrs. (Shaft Size 2150mm (width) x<br>2100mm (depth) ) with door opening of 800mm (width) and 2100 mm (height) . The equipment should be BMS compatible.All<br>electrical components with wiring from the single point power supply at top landing .

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.