Electrification Work For The Gfups Adukkathbayal Kasaba, Kasargod (re-tender)

BOQ Items
ItemQuantityUnitsRateAmount
... more
A- Point Wiring
0 -
... more
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
102point 82829.09999999999
... more
B- Circuit Wiring
0 -
... more
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
385metre 25417.699999999997
... more
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
235metre 23272.05
... more
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
200metre 29312
... more
C- Networking / Others
0 -
... more
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
120metre 5386.8
... more
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
12each 2772.84
... more
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1each 150.53
... more
1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
150metre 3763.5
... more
od37310/2019_2020 : Supply and Installation of Information out let RJ 11
1each 622
... more
od37311/2019_2020 : Supply and Installation of Information out let RJ 45 Cat 6
7each 4354
... more
od37312/2019_2020 : Supply and fixing of 9U Rack in telephone and Tv use inclding all connecting items etc as required.
1each 6060
... more
90.5.1.10 : Gong bell 300mm-without MS box
1each 1536.73
... more
1.19 : Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
40metre 1531.6
... more
D- Sockets
0 -
... more
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).
45each 18598.05
... more
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
15each 8041.200000000001
... more
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
3each 3881.9700000000003
... more
E- DB/MCB
0 -
... more
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
2each 9459.08
... more
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1each 6467.54
... more
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
40each 9137.2
... more
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
14each 129.36
... more
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2each 1790.46
... more
2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
1each 1134.22
... more
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2each 6079.12
... more
od37368/2019_2020 : Supplying and fixing 40 amps to 63 Amps Three Pole rating,415 volts, `C' Curve , miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning, etc. as required . (a) 63 amps three Pole
2each 4326
... more
F- Earthing
0 -
... more
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2set 11426.74
... more
od37395/2019_2020 : Supply, Laying and clamping of earth strip/ wire inclusive of providing earth termination and bracing of termination etc No 10 copper wire
190metre 17290
... more
G- Cable/ Cable termination
0 -
... more
od37400/2019_2020 : 10 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE
50metre 6150
... more
od37401/2019_2020 : 16 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE
18metre 2880
... more
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
68metre 2244.68
... more
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
4set 1072.16
... more
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2set 673.4
... more
H- Conduit laying
0 -
... more
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
420metre 31609.2
... more
I- electrical fittings
0 -
... more
od37411/2019_2020 : GENERAL PURPOSE LUMINAIRES. Supplying and fixing following SLEEK RD- surface mounted or recessed Round or Square Down light 112545 BGSLO Sleek surface 18W WH RD cool white LED down light fo soft diffused lighting complete light out put on ceiling / wall including connection with 1sq.mm FRLS PVC insulated copper conductor multi stranded three core cable etc as required (Make Philips,Crompton Greeves.)testing and commissioning
53each 58830
... more
od37412/2019_2020 : Supply, installation, testing and commissioning of following exhaust fan in the exisitng opening, including making the hole to suit the size of the above fan, making good damage, connection, testing, commisioning etc. as required. (a) 230 mm metal body (Make:- Almonard - light duty)<br>
8each 15544
... more
od37413/2019_2020 : Supply, installation, testing and commissioning of Bulk head light including 9W LED light fixtures
8each 4848
... more
od37414/2019_2020 : Supply, installation, testing and commisioning ofEndura well Glass Neo - IP65 Environmental Friendly energy saving long life, Corrosion resistant, Vertical horizontal surface mounting pressure die -cast aluminium well glass luminaries with high power led as light source. 40W LED 6000K LHEMABNDPN7S040 or equivalent.<br>
3each 20841
... more
od37415/2019_2020 : Supply and fixing of Angle holder or pendent type with 9w LED lamp.Including Lamp Shade.<br>
6each 2040
... more
od37416/2019_2020 : Supply, installation, testing and commisioning of following sweep ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper condutor, single core cable etc. as required. (a) 1200 mm sweep ceiling fan white shade with stepped type electronic fan regulator (Usha (Striker)/,Crompton(High breeze)/ Havells (Velocity))<br>
24each 56328
... more
J- Meter board/ Paper works
0 -
... more
od37443/2019_2020 : Fabrication, supply erection testing and commissioning of metering board with dust and vermin,weather proof, made out of 16 swg Powder coated CRCA sheet. The board should be chemically treated and coated with two coats of metal primer and two coats of siemens grey enamel paints. including HRC Fuse link, 125A SFU WITH 4numbers CT Provision including CT. Appro. size.... Provision for three phase meter(KSEB) - 1Sets. including handles , all connecting items fuses etc..,.125A HRC Fuse 3NOS
1each 29193
... more
od41081/2019_2020 : KSEB Charges including connection charges, agreement charges ,drawing preparation ,Submission etc as required. Preparation of all drawings and documents, submitting of Completion certificates to KSEB obtaining power connection etc. for commissioning of the whole installation in the premises.
1job 10000

1 KERALA STATE COASTAL AREA DEVELOPMENT CORPORATION LTD 1 st Floor, Chalachitra Kalabhavan Building, Vazhuthacaud, Jagathy P.O. , Thiruvananthapuram – 14, Phone: 0471 2321520, Fax: 2323363, E-mail: kscadc@gmail.com NO: 774/E/12/KSCADC Date: e-Government Procurement (e-GP) NOTICE INVITING TENDER TENDER NO- The Chief Engineer, Kerala State Coastal Area Development Corporation Ltd , Thiruvananthapuram for and on behalf of the Governor of Kerala invites online bids from the Registered Bidders of PWD, & CPWD . 1 Name of work 2 Estimate Amount ( PAC) 3 Earnest Money Deposit(EMD) 4 Tender Submission Fee 5 Period of completion 6 Classification of Bidder 7 Tender Documents Can be downloaded from the web site www.etenders.kerala.gov.in 8 Last Date and Time of receipt of Tenders 9 Date and Time of Opening of Tenders 2 Tender documents and tender schedule may be downloaded free of cost from the e-GP Website www.etenders.kerala.gov.in. A bid submission fee of Rs. ……………………. Shall be remitted as online payment All bid/tender documents are to be submitted online only and in the designated cover(s)/ envelope(s) on the e-GP website. Tenders / Bids shall be accepted only through online mode on the e-GP website and no manual submission of the same shall be entertained. Late tenders will not be accepted. The Scanned Copies of Registration certificate duly attested by a Gazetted Officer. Preliminary Agreement, Tender Documents duly filled, e-payment form duly filled in and GST Registration certificate shall be submitted online. Subsequently the following documents should be submitted by speed post /Registered Post only so as to reach this office on or before……………………... 5.00 PM. 1. Preliminary Agreement in original duly signed by the Bidder ( on KERALA STAMP PAPER worth Rs.200/-) 2. Gazzated officer Attested copy of valid contractors Registration Certificate 3. e-payment details 4. GST Registration Certificate Copy Name of the work for which the tender is submitted shall be mentioned in writing on top of the envelope containing the above 3 documents. More details on EMD & Cost of Tender documents/ bid submission fee are mentioned in the Form 83document. The bids shall be opened online at the office of the MANAGING DIRECTOR, KSCADC on …………………………. at……………………. by the CHIEF ENGINEER, KSCADC TVM, If the tender opening date happens to be on a holiday or non- working day due to any other valid reason, the tender opening process will be done on the next working day at same venue and time. 3 Online Tenders / bids are to be accompanied with a preliminary agreement executed in Kerala Stamp paper worth Rs.200/-. Tenders / bids received online without the scanned copies of Registration certificate duly attested by the Gazzated officer, Sighned Preliminary agreement, e- payment form duly filled in and Technical Bid Documents duly filled in will not be considered and shall be summarily rejected. Further details can be had from the NIT or from the Office of the MANAGING DIRECTOR, KSCADC, TVM, during working hours. . The Kerala State Coastal Area Development Corporation Ltd will not be responsible for any error like missing of schedule data while downloading by the Bidder. The Electrical Contractor should obtain clearance certificate from the Electrical Inspectorate after completion of work. In case of major electrical works it will be the responsibility of the contractor to obtain all neccesary clearence including permit for Electrical inspectorate on completion of the work. CHIEF ENGINEER 4 FACING SHEET KERALA STATE COASTAL AREA DEVELOPMENT CORPORATION LTD 1 st Floor, Chalachitra Kalabhavan Building, Vazhuthacaud, Jagathy P.O. Thiruvananthapuram – 14, Phone: 0471 2321520, Fax: 2323363, E-mail: kscadc@gmail.

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.