Kerala Rural Water Supply And Sanitation Agency Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KRWSA_641568_3Tender No
KRWSA/RPMU/IDKI/SUS/TEN/20/23Tender Authority
Kerala Rural Water Supply And Sanitation Agency ViewPurchaser Address
-Website
http://https://jalanidhi.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching, refilling
& testing of joints complete as per direction of Engineer in Charge. 20 mm dia 10 Kgf/cm2
490
-
-
Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2
1200
-
-
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2
200
-
-
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching
refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2
320
-
-
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching,
refilling & testing of joints compete as per direction of Engineer in Charge. 40 mm dia 6 Kgf/cm2
800
-
-
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 32mm Dia.
490
-
-
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 40mm Dia.
630
-
-
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 50mm Dia.
60
-
-
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in
position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent
cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and
specials).
32 mm nominal outer dia pipes.
490
-
-
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in
position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent
cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and
specials).
40 mm nominal outer dia pipes.
630
-
-
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in
position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent
cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and
specials)
50 mm nominal outer dia pipes.
900
-
-
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in
position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent
cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and
specials).
63 mm nominal outer dia pipes.
90
-
-
Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately)
External work - 40 mm nominal dia
90
-
-
Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately)
External work - 50 mm nominal dia
60
-
-
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and
dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and
then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach
deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a
lead of 50 m :
All kinds of soil
569.7
-
-
House Connection Work.-Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC /
HDPE mains up to 110 mm dia., up to a length of 5m using 20mm Indian Standard Class 6 uPVC pipe
and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers,
PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete
including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench
of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter,
lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire
for tools, cost of consumables and labour charges but excluding cost of water meter and meter box and
excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the
departmental officers.
90
-
-
Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using
20mm Indian Standard Class 6 uPVC pipes and specials including cost of consumables, hire for tools
and labour charges etc., complete but excluding cost of materials and as per the directions of the
department officers.
90
-
-
Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian
Standard Class 6 uPVC pipes and specials including cost of consumables, hire charges for tools and
labour charges etc. complete, but excluding cost of materials and as per the direction of departmental
officers.
90
-
-
Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the
sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including
the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting,
watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental
officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical
means and carrying out the excavation.
170
-
-
Refilling the trenches with a wet mix of close graded granular materials (Stone aggregate - 25mm
nominal size - 17.5%, Stone aggregate - 10mm nominal size - 17.5%, Crushed Stone - 2.36mm to
12.5mm - 25%, Stone chippings / screenings - 4.75mm nominal size - 20%, Stone chippings / screenings
- 150 micron nominal size - 20%), mixing properly after adding sufficient quantity of water, refilling in
layers not exceeding 150mm, compacting properly at Optimum Moisture Content with Surface Plate
Vibrator and disposing the excavated material etc. complete, including traffic control, providing caution
boards and as per direction of Engineer-in-charge for road restoration works in pipeline leak sites.
10.2
-
-
Pumping Main.-Supply of PE Pipe, PE100, PN12.5, 63mm dia, conforming to IS 4984/2016.
1400
-
-
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in
position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent
cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and
specials).
63 mm nominal outer dia pipes.
1400
-
-
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and
dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and
then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach
deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a
lead of 50 m :
All kinds of soil
(Ref. Item No. 2.10.1 of DSR)
378
-
-
Pump House- Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
0.63
-
-
Providing and Fixing of Booth Type Pump House with iron sheet.-
1
-
-
Reservoir- Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per
manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including
one coat of special primer applied @ 0.75 ltr /10 sqm
40.47
-
-
Scheme Labeling.
1
-
-
Water Quality Testing.
1
-
-
Providing and fixing of Platform Size60*70*075 cm and 1.2 m 63 mm Pvc Stand post with
cement concrete 1:3:6(1 cement,3 fine sand and 6 aggregate 20 mm nominal)
1
-
-
Mobile Operating System.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements