Kerala Police Housing And Construction Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 23,850Document Cost
₹ 2,301Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KPHCC_683900_1Tender No
NIT No.59/KPHCC/2024-25Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
2.33.2 Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth
3
-
-
50.2.33.6 Cutting branches of trees overhanging above any structures of girth between 60cm to 90cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete
15
-
-
50.2.33.8 Cutting branches of trees overhanging above any structures of girth beyond 120cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete.
8
-
-
OD1367/2024-2025 Labour Engaged for coolie
10
-
-
OD1368/2024-2025 Wood cutter per day
4
-
-
OD1369/2024-2025 DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 0.60 m long (30 cm in rock and 30cm in concrete ) including drilling holes of 20mm dia to a depth of 0.30m in rock and filling the gap with cement grout( 0.075kg/each) etc complete.
50
-
-
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
4.86
-
-
4.3.1 Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
21.6
-
-
50.10.1 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
1821.23
-
-
10.25.2 Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
40.68
-
-
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
86.16
-
-
OD1370/2024-2025 Supplying and fixing bittom fixture bush(adopter for 75mm pipe into 50mmpipe acting as a insulator to energizethe raiser pipe,the bush must be made of virgin PP or equivalent material and UV Stabilised)including all cost and conveyance etc complete
90
-
-
OD1371/2024-2025 providing and fixing reel insulator made up of virgin durable quality, sturdiness, unit weight 18g or nearest , withstanding voltage 15kV 15 kV
34
-
-
OD1372/2024-2025 Supplying and fixing permanent wire Tightner corrosion resistant pressure diecasting process, using LM6 grade aluminum alloy. it is used to tighten fence wire and maintain adequate tension. etc. complete as per the direction of engineer in charge
249
-
-
OD1373/2024-2025 Supply and fixing of Super Strain insulator (Poly propylene, br400 N, 15 KV Guy type )
11
-
-
OD1374/2024-2025 providing warning signs poly-rthlene plastic with statutory colour and signs
30
-
-
OD1375/2024-2025 providing and fixing of bullets(connectors)-copper material or aluminium or stainless steel material having an inner core hole size of 2.5mm dia ,2cm length including all cost
2500
-
-
OD1376/2024-2025 Providing and laying of fence wire SWG 12 ACSR high tension hot dipped, size 2.59 mm, standard IS 398-part2 /1996, breakage capacity 600kg, purity of zinc 99.95% wof coating 230g/m2, GI systematic make etc. complete as per direction of engineer in charge.(Quality of ACSR wire should be assured with test result and certificates)
3000
-
-
OD1377/2024-2025 Providing and fixing 3.2 Mtr spiral model GI fence wire 14 SWG (hanging type) Approved make etc. complete. as per direction of engineer in charge.(Quality of GI fence wire should be assured with test result and certificates)
2500
-
4.86
ELECTRICAL WORKS
-
-
-
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A
1
-
-
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
15
-
-
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1
-
-
OD1378/2024-2025 providing and fixing of lightning diverter must be capable of diverting stray lightening. The diverter assembly must be adjustable for spark gaps. : Adequate earthing to be provided
1
-
-
OD1379/2024-2025 Supply and fixing of Solar Charge Controller with display 12v/24v to regulate the charging of the battery of approved brand
1
-
-
OD1380/2024-2025 Fabrication Supply and installation of Module Stand and water proof Battery and equipment safety box with following specifications 50mm dia 2.75mtr long gi base pipe and connect L angle through pipe for fixing 2nos solar panels and providing dust,water and vermin proof floor mounting cubicle type rack fabricated from 1.6mm/16swg CRCA sheet,and powder coated ,hinged door,rubber beedings and provision for energizer,charge controller and 2 nos of battery etc as required.
1
-
-
OD1381/2024-2025 Supply and Installation of 12 volt 150AH Solar VRLA , SMF battery with connecting wires etc as required Exide/amron/Hykon or equivalent
1
-
-
OD1382/2024-2025 providing and fixing 160 watts, mono crystalline solar panel 12 volts rating with minimum 10 years performance warranty against manufacturing defects. Make waree ,adani or equivalent
1
-
-
OD1383/2024-2025 providing and fixing GSM alert system with fence voltage alarm and sms alert to mobile number
1
-
-
OD1384/2024-2025 Supply and installation of Energizer with following specification; 12 V Energizer of Make:JVA dual zone with adaptor or equivalent ,must confirm to IEC standard 60335.2.76 or IS 302-3-76 (1999) and all national and international standards of safety ,switch to high and low power setting , solar panel option to recharge 12volt battery ,Should possess the following output characters , Peak o/p voltage not more than 10kv on 50Kload , o/o energy 3.5 J minimum pulse duration 1.01-3.0m sec- ,Pulse interval 1.1- 1.4 sec , peak current 7.0-8.0 A .
1
-
-
OD1385/2024-2025 Providing Digital volt meter must display fence voltage in kilowatt up to 9.9kv including all cost
1
-
-
OD1386/2024-2025 supply of Tool Kit cutting pliers, crimping tool, multi meter, double ended spanner etc as required
1
-
-
OD1387/2024-2025 supply and drawing DC Solar cable 4 sq mm single run with UV protection of reputed brand connection etc as required
10
-
-
OD1388/2024-2025 Providing and laying of Lead Out Cable must be double insulated withstanding 15KV voltage and inner core wire must be GI
15
-
-
OD1389/2024-2025 supply and installing multi spike Lightning arrester Must be capable of diverting stray lightning in suitable height including GI pipe for fixing and concrete/equivalent for fixing on the ground
1
-
-
OD1390/2024-2025 Earthing system Must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rod grade 304 or above non rusting quality of 4 feet long
5
-
-
Evaluation Notes How It Works ?