Technopark Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Technopark Tender

Works
Electrical and Electronics
Eprocure
Opening Date19 Jun 2024
Closing Date5 Jul 2024
Tender Amount₹ 3,00,00,000 
Notes
Download

Costs

Summary

Electrification Works Of Commercial Building, Technopark Phase I Campus

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, installation, testing & commissioning of indoor type floor mounted, dust and vermin proof, 11 KV VCB (OEM) panel with 12kV, 630A, 21kA for 1 sec, horizontal drawout, horizontal isolation type vacuum circuit breaker, the panel shall be fully type tested as per IEC 62271-200 as amended up to date. The operating mechanism shall be electrically spring charged and auto/manually closing breaker capable of remote operation & monitoring through SCADA with fully interlocked, rack in and rack out mechanism, air insulated with support insulators/Self supported type aluminum bus bars of 630 Amps capacity and as per detailed technical specification, SLD enclosed and meeting the specified IS, IEC, and KSEI standards.

1

-

-

... More
Power Pack/UPS: HT panel shall include a POWER PACK/UPS of required capacity for auxiliary power supply unit with all accessories required for complete installation.

-

-

-

... More
INCOMER (a) 01 No, 630A, 21kA VCB (b) 3 No. – 11 KV / 110 V PT (resin cast) with 0.5 accuracy class and 100 VA burden with 1 No. Voltmeter (0-15KV), digital type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer. (c) 3 No. CT's (resin cast) with ratio 200/100/5 A of 15 VA burden and accuracy Class – 0.5, 3 No. – (0-200 A) digital type ammeters. (d) 1 No. – Microprocessor-based numerical relay with 2 nos O/L, 1 E/F and S/C protection. (e) 1 – Set of dual core dual ratio CTs (3 nos) (resin cast) 200/100/5 A of 15 VA burden and accuracy Class –class 5P10 for protection.

-

-

-

... More
OUTGOING-01 (a) 01 No, 630A, 21kA VCB (b) 3 No. CT's (resin cast) with ratio 100/50/5A of 15 VA burden and accuracy Class – 0.5, 3 No. – (0-100 A)digital type ammeters. (c) 1 No. – Microprocessor-based numerical relay with 2 nos O/L, 1 E/F and S/C protection. (d) 1 – Set of dual core dual ratio CTs (3nos) (resin cast) 100/50/5 A of 15 VA burden and accuracy Class –class 5P10 for protection. (e) 1 – Set HT TOD meter with RS485 communication port with dual core CTs (resin cast) (3nos) with ratio 100/50/5 A of 15 VA burden and accuracy class –0.2s and PTs (3 nos) 11 KV/ 110V PT with 0.2 accuracy class and 100VA burden.

-

-

-

... More
OUTGOING-02 (a) 01 No, 630A, 21kA VCB (b) 3 No. CT's (resin cast) with ratio 100/50/5A of 15 VA burden and accuracy Class – 0.5, 3 No. – (0-100 A) digital type ammeters. (c) 1 No. – Microprocessor-based numerical relay with 2 nos O/L, 1 E/F and S/C protection. (d) 1 – Set of dual core dual ratio CTs (3nos) (resin cast) 100/50/5 A of 15 VA burden and accuracy Class –class 5P10 for protection. (e) 1 – Set HT TOD meter with RS485 communication port with dual core CTs (resin cast) (3nos) with ratio 100/50/5 A of 15 VA burden and accuracy class –0.2s and PTs (3 nos) 11 KV/ 110V PT with 0.2 accuracy class and 100VA burden.

-

-

-

... More
The following operations of the HT Panel shall be performed through ECS (Electrical Control Sysytem): 1. I/C- ON, OFF & RESET 2.O/G-01- ON, OFF & RESET 3.O/G-02 ON, OFF & RESET The following status parameters of the HT Panel shall be monitored through ECS (Electrical Control Sysytem): 1. I/C- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 2.O/G-01- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 3.O/G-02- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE

-

-

-

... More
The following parameters from the numerical relays shall be monitored through ECS: 1. I/C- Num relay operated on Earth Fault, Ovr crt, Short Ckt 2. O/G-01- Num relay operated on Earth Fault, Ovr crt, Short Ckt 3. O/G-02- Num relay operated on Earth Fault, Ovr crt, Short Ckt The following parameters from all TOD meters & kWH meteres shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost

-

-

-

... More
TRANSFORMER - 750 kVA 11kV/433V Cast Resin (Dry type)

-

-

-

... More
Supply, installation, testing & commissioning of 750 kVA 11kV/433V 3-phase 50 Hz Indoor cast resin dry type transformer, having vector group Dyn 11 with tapping +5% to -5% in steps of 2.5% by off-circuit tap links. The transformer shall include winding temperature indicators for each phase and the core. Total Loss at Rated Voltage at Principal Tapping, Rated Frequency, with 100% load at 120°C shall be less than 8500W(+/-5%). The transformer shall be complete with all accessories as required, conforming to KSEI, ECBC, IE rules, and specifications, and meeting IEC 60076-11 standards with the latest amendments. (All associated works, including loading, unloading at the site, erection at the site, and movements, etc., shall be within the scope of work)

2

-

-

... More
DG Sets

-

-

-

... More
DG SET-500kVA

-

-

-

... More
Supply, installation, testing and commissioning of 3phase 415V, 0.8pf 50Hz. DG set of the ratings 400KW/500 KVA, Water cooled Diesel generating set of prime duty comprising of diesel engine alternator, inbuilt fuel tank & Separate 700 ltr day tank with necessary fuel line pipe of 25mm MS pipe (heavy duty type) with necessary bends, clamps,supports and valves,painting as required, automatic starting system, battery, battery charger, electronic governor etc with all accessories required for synchronising the DG with another DG. The Generator set shall have a integral type acoustic enclosure as per latest CPCB norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with CPCB IV+ specifications. Generator set inclusive of fly wheel, flexible coupling, air cleaner, corrossion resistor, fan with guard, fuel pump, fuel filter, electrical starting system with starter, 24V battery with regulator, instrument panel, rpm indicator, residential silencer, complete with necessary control wiring compatible with SCADA, interconnections etc. including first filling of oil and diesel for commissioning of the DG set. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary vibration isolation arrangement as per recommendations of manufacturer, which shall be installed on suitable cement concrete foundation as per manufacturers' standards. Exhaust pipe with suitable specifications with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 20 m in stages including suitable rain gaurd for top. Fixing shall be done with proper clamps, expansion bolts, support angle of size 40 X 40 X 6 mm fixed on the wall/ inside the duct as instructed by the Engineer.

1

-

-

... More
DG SET-320kVA

-

-

-

... More
Supply, installation, testing and commissioning of 3phase 415V, 0.8pf 50Hz. DG set of the ratings 250 KW/320 KVA, Water cooled Diesel generating set of prime duty comprising of diesel engine alternator, inbuilt fuel tank & Separate 500 ltr day tank with necessary fuel line pipe of 25mm MS pipe (heavy duty type) with necessary bends, clamps,supports and valves,painting as required, automatic starting system, battery, battery charger, electronic governor etc with all accessories required for synchronising the DG with another DG. The Generator set shall have a integral type acoustic enclosure as per latest CPCB norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with CPCB IV+ specifications. Generator set inclusive of fly wheel, flexible coupling, air cleaner, corrossion resistor, fan with guard, fuel pump, fuel filter, electrical starting system with starter, 24V battery with regulator, instrument panel, rpm indicator, residential silencer, complete with necessary control wiring compatible with SCADA, interconnections etc. including first filling of oil and diesel for commissioning of the DG set. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary vibration isolation arrangement as per recommendations of manufacturer, which shall be installed on suitable cement concrete foundation as per manufacturers' standards. Exhaust pipe with suitable specifications with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 20 m in stages including suitable rain gaurd for top. Fixing shall be done with proper clamps, expansion bolts, support angle of size 40 X 40 X 6 mm fixed on the wall/ inside the duct as instructed by the Engineer.

1

-

-

... More
LT - PANELS

-

-

-

... More
MSB

-

-

-

... More
Fabrication Supply installation testing and commissioning of 1600A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 14SWG thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital ammeters with cast resin type CTs and Digital Voltmeter with selector switch or Multifunction meters, indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections, electrical interlocks, including mounting the following switch gears as per SLD with IP54

1

-

-

... More
Incomer:

-

-

-

... More
1250A, 50kA,4P,uP Based, Eelectrically draw out type ACB with O/L,O/C (2 nos) & E/F (1no) release and with all accessories- 2 No

-

-

-

... More
Advanced Multifunction meter- Cl 1- 2 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. The MFM shall be capable of RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)

-

-

-

... More
1000/5A ,10 VA,Cast resin type ,CL:1 ,CT-6 Nos

-

-

-

... More
Earth fault relay- 2 No

-

-

-

... More
200/5A ,10 VA,Cast resin type ,CL:5P10 ,CT-2 Nos

-

-

-

... More
Bus coupler:

-

-

-

... More
1250A, 50kA,4P,uP Based EDO ACB with O/L,O/C&E/F release- 1 No

-

-

-

... More
Outgoings:

-

-

-

... More
800A, 50kA,4P,uP Based EDO ACB with O/L,O/C&E/F release and all accessories- 1 No

-

-

-

... More
630A, 25 kA or above,uP based 4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1 No

-

-

-

... More
400A, 25 kA or above,μP,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-2 No

-

-

-

... More
3-phase TOD meter,class 0.5s with RS 485 communication port -2 Nos (The contractor should arrange for testing of CT & meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
650/5A ,10 VA,Cast resin type ,CL:0.5s ,CT-3 Nos

-

-

-

... More
300/5A ,10 VA,Cast resin type ,CL:0.5s ,CT-3 Nos

-

-

-

... More
The following operations of the MSB shall be performed through ECS (Electrical Control Sysytem): 1. I/C-01- ON, OFF & RESET 2. I/C-02- ON, OFF & RESET 3. B/C- ON, OFF & RESET The following status parameters of the MSB shall be monitored through ECS (Electrical Control Sysytem): 1. I/C-01- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 2. I/C-02- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 3. B/C- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE

-

-

-

... More
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all TOD meters & kWH meters shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost

-

-

-

... More
DG SYNC PANEL

-

-

-

... More
Fabrication Supply installation testing and commissioning of 1600A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 14SWG thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital ammeters with cast resin type CTs and Digital Voltmeter with selector switchor Multifunction meter, indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections including mounting the following switch gears as per SLD with IP54

1

-

-

... More
DG Incomer 1 & 2:

-

-

-

... More
800A,50kA,3P,uP Based EDO ACB with O/L,O/C& E/F release- 1 No

-

-

-

... More
500A, 36 kA or above,up based,3P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1 No

-

-

-

... More
Advanced Multifunction meter- Cl 1- 2 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. The MFM shall be capable of RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)

-

-

-

... More
700/5A ,15 VA,Cast resin type ,CL:1 ,CT-3 Nos

-

-

-

... More
450/5A ,10 VA,Cast resin type ,CL:1 ,CT-3 Nos

-

-

-

... More
Earth Fault Relay- 2 No

-

-

-

... More
140/5A,15 VA,Cast resin type ,CL: 5P10 ,CT-1 Nos

-

-

-

... More
90/5A,15 VA,Cast resin type ,CL: 5P10 ,CT-1 Nos

-

-

-

... More
350A Neutral Contactor- 1 No 250A Neutral Contactor- 1No

-

-

-

... More
Bus Coupler:

-

-

-

... More
800A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1No

-

-

-

... More
Outgoings:

-

-

-

... More
800A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1No

-

-

-

... More
500A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1No

-

-

-

... More
400A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1No

-

-

-

... More
DG Synchronization and Load sharing System( with DIEF) of new 500kVA DG Set with new 320kVA DG set in the proposed DG Sync Panel

-

-

-

... More
Suppty installation testing and commissioning of DG auto synchronization and auto load sharing system using DEIF controller with IOM module Synchronisation controller should have inbuilt synchronoscope, double frequency and double voltmeter. -The controller shall have provision for four modes of operation Off / Manual / Semi Automatic and Automatic operation freely selectable by operator at site from the operating panel.The controller shall have built in hooter alarm with acknowledge keys. Analog regulation module for GOVERNOR and AVR should placed at DG side with can bus communication. Controller should have in built protection for reverse power 2 levels, over current 6 levels, voltage dependent over current, over voltage 2 levels, under voltage 3 levels, over frequency 3 levels, under frequency 3 levels, overload 5 levels, unbalanced current etc. All synchronization controller in system shall have USB port for programming. Modbus (rs485) and ethernet communication - for remote/SCADA monitoring, CAN bus for load sharing communication for synchronization control. All Generator parameter can be monitored through the controller HMI and SCADA system (Vph,Vll,I,KVA,KW,KVAR,KWH,PF,FREQ). Integration of new DEIF system with existing SCADA is included in the scope of work.

-

-

-

... More
COMMON PANEL

-

-

-

... More
Fabrication Supply installation testing and commissioning of 250A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 14SWG thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital ammeters with cast resin type CTs and Digital Voltmeter with selector switch or Multifunction meters, indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections, PLC based autochangeover & electrical interlocks, including mounting the following switch gears as per SLD with IP54

1

-

-

... More
Incomer:

-

-

-

... More
250A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 No

-

-

-

... More
Advanced Multifunction meter- Cl 1- 1 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. MFM shall be capable of RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)

-

-

-

... More
200/5A ,10 VA,Cast resin type ,CL:1 ,CT-3 Nos

-

-

-

... More
Outgoings:

-

-

-

... More
63A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 7 Nos

-

-

-

... More
Dual Source Energy meter (CT Operated, Flush mounted type) with RS485 communication- 3 Nos

-

-

-

... More
50/5A, 10VA, CL:0.5s cast resin current transformer- 9 Nos (The contractor should arrange for testing of CT in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all Dual Source meters shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost

-

-

-

... More
SSB-TENANT

-

-

-

... More
Fabrication Supply installation testing and commissioning of 400A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 14SWG thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital ammeters with cast resin type CTs and Digital Voltmeter with selector switch or Multifunction meters, indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections, PLC based autochangeover & electrical interlocks, including mounting the following switch gears as per SLD with IP54

1

-

-

... More
Incomer:

-

-

-

... More
400A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-2No

-

-

-

... More
Advanced Multifunction meter- Cl 1- 2 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. MFM shall be capable of RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)

-

-

-

... More
300/5A ,10 VA,Cast resin type ,CL:1 ,CT-6 Nos

-

-

-

... More
Outgoings:

-

-

-

... More
160A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 No

-

-

-

... More
200A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 3 Nos

-

-

-

... More
250A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 2 No

-

-

-

... More
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost

-

-

-

... More
SSB- COMMON AREA

-

-

-

... More
Fabrication Supply installation testing and commissioning of 800A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 14SWG thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital ammeters with cast resin type CTs and Digital Voltmeter with selector switch or Multifunction meters, indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections, PLC based autochangeover & electrical interlocks, including mounting the following switch gears as per SLD with IP54

1

-

-

... More
Incomer:

-

-

-

... More
800A, 36 kA or above,uP based,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-2No

-

-

-

... More
Advanced Multifunction meter- Cl 1- 3 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)

-

-

-

... More
650/5A ,10 VA,Cast resin type ,CL:1 ,CT-6 Nos

-

-

-

... More
Outgoings:

-

-

-

... More
630A, 25 kA or above,TM,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-3 No

-

-

-

... More
400A, 25 kA or above,TM,4P ,Variable settings, MCCB with all accessories including spreader link and extended rotary handle-1 No

-

-

-

... More
250A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 Nos

-

-

-

... More
250A,25kA, 4P, Switch disconnector- 1 No

-

-

-

... More
3-phase TOD meter,class 0.5s with RS 485 communication port - 2 No (The contractor should arrange for testing of meters & CTs in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
3 ph kwh meter Flush Mounted Type(CT operated),Class 0.5s with RS 485 communication port in the existing metering panels (Dual metering arrangement required as per SLD)- 2 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
MNX 25 3p Contactor for dual source arrangement for metering of two source of supply(Main supply and DG supply) - 2 Nos

-

-

-

... More
400/5A ,10 VA,Cast resin type ,CL:0.5s ,CT-6 Nos

-

-

-

... More
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all TOD meters & kWH meteres shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost

-

-

-

... More
APFC PANEL- 225 kVAR

-

-

-

... More
Fabrication Supply installation testing and commissioning of 630A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 14SWG thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital ammeters with cast resin type CTs and Digital Voltmeter with selector switch or Multifunction meters, APFC Relay (7-stage)/ Controllers, Indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections, PLC based autochangeover & electrical interlocks, including mounting the following switch gears as per SLD with IP54

1

-

-

... More
Incomer:

-

-

-

... More
630A, 4-pole 25 kA,MCCB, Microprocessor type, variable settings ,extended rotary handle,Spreader Terminals, etc as required- 1 nos

-

-

-

... More
Outgoings:225 kVAR

-

-

-

... More
3 set of 50 KVAR MPP (Metalised Poly Propylene) Capacitor with 125A,TP, 16kA MCCBs,Cap.Duty Contactors,7% detuned Al reactor with switching steps in the rating of 50 KVAR as required.

-

-

-

... More
2 set of 25 KVAR MPP (Metalised Poly Propylene) Capacitor with 63A,TP, 16kA MCCBs,Cap.Duty Contactors,7% detuned Al reactor with switching steps in the rating of 25 KVAR as required.

-

-

-

... More
1 set of 15 KVAR MPP (Metalised Poly Propylene) Capacitor with 40A,TP, 16kA MCCBs,Cap.Duty Contactors,7% detuned Al reactor with switching steps in the rating of 20 KVAR as required.

-

-

-

... More
1 set of 10 KVAR MPP (Metalised Poly Propylene) Capacitor with 40A,TP, 16kA MCCBs,Cap.Duty Contactors,7% detuned Al reactor with switching steps in the rating of 4 KVAR as required.

-

-

-

... More
With necessary Aluminium busbars, interconnections, providing Digital Voltmeter,Ammeter , RYB and “ON / OFF / TRIP" indicating lamp at incomer, control PT, CTs, MPCBs and MCB and APFC Relay etc. and all other necessary accessories as per the specification/SLD. Each KVAR capacitor in a separate compartment with necessary ventilation arrangemnts or weld mesh arrangements as required by the KSEI guidelines

-

-

-

... More
METERING PANEL- MP-GF

-

-

-

... More
Fabrication Supply installation testing and commissioning of 200A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 14SWG thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital ammeters with cast resin type CTs and Digital Voltmeter with selector switch or Multifunction meters, indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections, PLC based autochangeover & electrical interlocks, including mounting the following switch gears as per SLD with IP54

1

-

-

... More
Incomer:

-

-

-

... More
200A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 No

-

-

-

... More
Advanced Multifunction meter- Cl 1- 1 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)

-

-

-

... More
160/5A ,10 VA,Cast resin type ,CL:1 ,CT-3 Nos

-

-

-

... More
Outgoings:

-

-

-

... More
63A,16kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 4 Nos

-

-

-

... More
40A,16kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 4 Nos

-

-

-

... More
3-phase TOD meter,class 0.5s with RS 485 communication port (Dual metering arrangement required as per SLD)- 8 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
3 ph kwh meter Flush Mounted Type(CT operated),Class 0.5s with RS 485 communication port in the existing metering panels (Dual metering arrangement required as per SLD)- 8 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
50/5A, 10VA, CL:0.5s cast resin current transformer- 24 Nos (The contractor should arrange for testing of CT in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
MNX 25 3p Contactor for dual source arrangement for metering of two source of supply(Main supply and DG supply) - 8 Nos

-

-

-

... More
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all TOD meters & kWH meteres shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost

-

-

-

... More
METERING PANEL- MP-FF

-

-

-

... More
Fabrication Supply installation testing and commissioning of 200A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 14SWG thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital ammeters with cast resin type CTs and Digital Voltmeter with selector switch or Multifunction meters, indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections, PLC based autochangeover & electrical interlocks, including mounting the following switch gears as per SLD with IP54

1

-

-

... More
Incomer:

-

-

-

... More
200A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 1 No

-

-

-

... More
Advanced Multifunction meter- Cl 1- 1 Nos (VAF + W/VA/PF/Wh with High/Low recording of VLL, VLN, A, Hz, PF, VAF with time stamp. Voltage & Current THD (Total Harmonics Distortion) with Individual harmonics. RTC based Demand management integration with EMS/SCADA system with RS485 serial channel communication, Industry standard Modbus RTU protocol.)

-

-

-

... More
160/5A ,10 VA,Cast resin type ,CL:1 ,CT-3 Nos

-

-

-

... More
Outgoings:

-

-

-

... More
63A,16kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 4 Nos

-

-

-

... More
40A,16kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle- 4 Nos

-

-

-

... More
3-phase TOD meter,class 0.5s with RS 485 communication port (Dual metering arrangement required as per SLD)- 8 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
3 ph kwh meter Flush Mounted Type(CT operated),Class 0.5s with RS 485 communication port in the existing metering panels (Dual metering arrangement required as per SLD)- 8 Nos (The contractor should arrange for testing of meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
50/5A, 10VA, CL:0.5s cast resin current transformer- 24 Nos (The contractor should arrange for testing of CT in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)

-

-

-

... More
MNX 25 3p Contactor for dual source arrangement for metering of two source of supply(Main supply and DG supply) - 8 Nos

-

-

-

... More
The following parameters from all MFM’s shall be monitored through ECS: 1. Voltage (L-L, L-N) 2. Current (L-L, L-N) 3. Power factor 4. Power- (kW, kVA, kVAR) 5. Energy- (kWh, kVAh, kVARh) 6. THD for V & I (3rd, 5th, 7th, & 9th order) 7. K-factor for Current The following parameters from all TOD meters & kWH meteres shall be monitored through ECS: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All control wiring and accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost

-

-

-

... More
ELECTRICAL CONTROL SYSTEM

-

-

-

... More
Design, Integration with the existing SCADA network (IEC 60870-5-104 protocol) with Supply of all required accessories, and Commissioning of Electrical Control System for monitoring and control of RMUs, HT & LT panels. The work includes necessary modifications in the Central SCADA system with required changes in programming, purchase of additional licenses if required, modification in the firewall, etc. Providing FRTU with necessary controller compatible with IEC 60870-5-104 protocol, Digital Input Module, Digital Output Module , Serial Communication Module for communication with MFM's using Modbus RTU, 24V DC Power Supply System with SMPS (Switched Mode Power Supply) and backup batteries, Surge Protectors, Managed Network Switches (for data communication through OFC connectivity) and 4G/advanced routers to communicate with the Central SCADA system as primary and secondary network sources, and with all necessary accessories will come under the scope of work. There shall be a separate dashboard for the Commercial Building in the Central SCADA HMI for remote monitoring and control of the Electrical Panels and the RMU parameters shall be integrated into the existing dashboard. A laptop should be supplied for configuring the system with processor: i3 11th Gen or above, RAM: 8 GB DDR4 or above, SSD: 256 GB.

1

-

-

... More
HT CABLE PART

-

-

-

... More
Supply of following sizes of XLPE insulated non-FRLS Aluminium conductor armoured power cables of 11kV grade confirming to IS 7098:1988 amended upto date

-

-

-

... More
1Cx500sqmm

450

-

-

... More
3Cx300sqmm

300

-

-

... More
3Cx185sqmm

70

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required and as per IS 1255:1983 amended upto date.

-

-

-

... More
1Rx1Cx500sqmm

150

-

-

... More
1Rx3Cx300sqmm

300

-

-

... More
1Rx3Cx185sqmm

10

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KVgrade of following size direct in ground in the same trench in one tier horizontal formationincluding excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS 1255: 1983 amended upto date

-

-

-

... More
1Rx1Cx500sqmm

300

-

-

... More
1Rx3Cx300sqmm

10

-

-

... More
1Rx3Cx185sqmm

10

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade offollowing size in the existing masonry open duct as required.

-

-

-

... More
1Rx1Cx500sqmm

20

-

-

... More
1Rx3Cx300sqmm

20

-

-

... More
1Rx3Cx185sqmm

70

-

-

... More
HT-End Termination & Joints

-

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit confirming to IS 13573 (Part 2) : 2011 completewith all accessories including lugs suitable for following size of XLPE aluminium conductorcable of 11 KV grade as required :

-

-

-

... More
1Cx500sqmm

6

-

-

... More
3Cx300sqmm

6

-

-

... More
3Cx185sqmm

8

-

-

... More
Supplying and making outdoor straight through cable jointing with heat shrinkable jointing kit confirming to IS 13573 (Part 2) : 2011 complete with all accessories including ferrules suitable for following size of XLPE aluminium conductor cable of 11 kV grade as required.

-

-

-

... More
1Cx500sqmm

1

-

-

... More
3Cx300sqmm

1

-

-

... More
3Cx185sqmm

1

-

-

... More
LT Cable

-

-

-

... More
Supply of following sizes A2XFY FRLS Aluminium conductor armoured power cables of 1.1kV grade confirming to IS 7098 (Part I) amended upto date

-

-

-

... More
3.5x400 Sqmm A2XFY (Aluminium) Cable

276

-

-

... More
3.5x300 Sqmm A2XFY (Aluminium) Cable

60

-

-

... More
3.5x240 Sqmm A2XFY (Aluminium) Cable

67

-

-

... More
3.5x185 Sqmm A2XFY (Aluminium) Cable

60

-

-

... More
3.5x120 Sqmm A2XFY (Aluminium) Cable

10

-

-

... More
3.5x95 Sqmm A2XFY (Aluminium) Cable

40

-

-

... More
3.5x70 Sqmm A2XFY (Aluminium) Cable

10

-

-

... More
3.5x50 Sqmm A2XFY (Aluminium) Cable

10

-

-

... More
4x16 Sqmm A2XFY (Aluminium) Cable

10

-

-

... More
4x10 Sqmm A2XFY (Aluminium) Cable

20

-

-

... More
4x6 Sqmm A2XFY (Aluminium) Cable

60

-

-

... More
4x4 Sqmm A2XFY (Aluminium) Cable

190

-

-

... More
3x4 Sqmm A2XFY (Aluminium) Cable

10

-

-

... More
Laying of one number A2XFY / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

403

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

70

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

60

-

-

... More
Upto 35 sq. mm

290

-

-

... More
Laying of one number A2XFY/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

50

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

30

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

30

-

-

... More
Upto 35 sq. mm

30

-

-

... More
LT- End Termination

-

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3.5x400 Sqmm A2XFY (Aluminium) Cable

34

-

-

... More
3.5x300 Sqmm A2XFY (Aluminium) Cable

4

-

-

... More
3.5x240 Sqmm A2XFY (Aluminium) Cable

8

-

-

... More
3.5x185 Sqmm A2XFY (Aluminium) Cable

8

-

-

... More
3.5x120 Sqmm A2XFY (Aluminium) Cable

2

-

-

... More
3.5x95 Sqmm A2XFY (Aluminium) Cable

4

-

-

... More
3.5x70 Sqmm A2XFY (Aluminium) Cable

2

-

-

... More
3.5x50 Sqmm A2XFY (Aluminium) Cable

2

-

-

... More
4x16 Sqmm A2XFY (Aluminium) Cable

2

-

-

... More
4x10 Sqmm A2XFY (Aluminium) Cable

2

-

-

... More
4x6 Sqmm A2XFY (Aluminium) Cable

4

-

-

... More
4x4 Sqmm A2XFY (Aluminium) Cable

4

-

-

... More
3x4 Sqmm A2XFY (Aluminium) Cable

2

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription"11kV UG Cable", bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground at every 100m interval.

30

-

-

... More
Supplying and laying 40mm dia HDPE PLB pipe duct with coupling collars for drawing optic fiber pilot wire through the PLB pipes as per drawing and as per direction of Technopark Officials, in the existing trench already made for laying 11kV UG Cable as per direction of Technopark

300

-

-

... More
Supply, laying and commissioning of fibre optical cable (24 fibre) from cable drums and laying through the 40mm PLB HDPE pipe carefully and neatly including loops, termination,supply of suitable terminal boxes, joint enclosures and connectors etc. complete on standard specifications and directions of Technopark officers at site

500

-

-

... More
LT Works

-

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.

-

-

-

... More
2Rx1.5sqmm with 1R 1.5sqmm Green wire for earthing

622

-

-

... More
2Rx2.5sqmm with 1R 1.5sqmm Green wire for earthing

3254

-

-

... More
2Rx4sqmm with 1Rx1.5sqmm Green wire for earthing

10

-

-

... More
3Rx4sqmm

325

-

-

... More
4Rx4sqmm with 1Rx1.5sqmm Green wire for earthing

10

-

-

... More
3Rx6sqmm

165

-

-

... More
Cat 6 cable

10

-

-

... More
Supplying and fixing of 20mm of medium class PVC conduit along with accessories in surface/recess including cutting the floor/ wall and making good the same in case of recessed conduit as required.

581

-

-

... More
Supplying and fixing of 25mm of medium class PVC conduit along with accessories in surface/recess including cutting the floor/ wall and making good the same in case of recessed conduit as required.

436

-

-

... More
Supplying and fixing of 20mm of PVC flexible conduit along with accessories in surface

30

-

-

... More
Supply and Fixing of 20mm ISI medium class PVC casing and capping of following dimensions along with accessories through wall in surface/ceiling

10

-

-

... More
Supply and Fixing of 25mm ISI medium class PVC casing and capping of following dimensions along with accessories through wall in surface/ceiling

10

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

50

-

-

... More
Wiring for two light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

14

-

-

... More
Wiring for three light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

14

-

-

... More
Wiring for four light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

36

-

-

... More
Wiring for five light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

14

-

-

... More
Supply and Installation of Independent plug point with 6A 3 pin plug socket controlled by 6A switch with suitable modular plate, GI box/PVC box in recess/ surface

24

-

-

... More
Supply and installation of combined modular plug point for 6A, 3 pin plug socket controlled by 6A modular switch in the same switch board with suitable modular plate, GI box/PVC box in recess/ surface

1

-

-

... More
Supply and Installation of Independent plug point with 16A plug socket controlled by 16A switch with suitable modular plate ,GI box/PVC box in recess/ surface.

10

-

-

... More
Supply and Installation of Computer Socket(R-J45 jack) with suitable modular plate , GI box/PVC box in recess/ surface.

10

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 100 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.

-

-

-

... More
3P 4W VDB Double Door

1

-

-

... More
3P 6W VDB Double Door

1

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
3P 4W VDB Double Door

9

-

-

... More
3P 6W VDB Double Door

1

-

-

... More
Supplying and fixing following 63 A four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Supplying and fixing following 40 A double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Supplying and fixing 40A, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required

1

-

-

... More
Supplying and fixing 32A, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required

9

-

-

... More
Supplying and fixing 32A, four pole, 415 V, isolator with metallic enclosure with connections, testing and commissioning etc. as required

1

-

-

... More
Supplying and fixing 40A, four pole, 415 V, isolator with metallic enclosure with connections, testing and commissioning etc. as required

1

-

-

... More
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connections, testing and commisioning.

-

-

-

... More
5A to 32A ,SP MCB

96

-

-

... More
5A to 32A ,FP MCB

2

-

-

... More
40A ,TP MCB

6

-

-

... More
MCB Blanking plate

10

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
32 A,4P

4

-

-

... More
40 A,4P

2

-

-

... More
63 A,4P

1

-

-

... More
Supply and fixing of LED recess mounted down light with minimum lumen outout of 500 Lumen, PC defuser, CRI=80PF=0.95 ,CCT =5700 K ,Efficacy =100 lm/W, THD=10%, constant current electronic driver should be equipped with surge protection upto 2kV

90

-

-

... More
Supply and fixing of LED Surface mounted down light with minimum lumen outout of 1400 Lumen, PC defuser, CRI=80PF=0.95 ,CCT =5700 K ,Efficacy =100 lm/W, THD=10%, constant current electronic driver should be equipped with surge protection upto 2kV

80

-

-

... More
Supply and fixing of LED recess mounted down light with minimum lumen outout of 500 Lumen, PC defuser, CRI=80PF=0.95 ,CCT =5700 K ,Efficacy =100 lm/W, THD=10%, constant current electronic driver should be equipped with surge protection upto 2kV

70

-

-

... More
Supply and fixing of LED recessed ceiling fixture 600X600mm with a minimum lumen output of 2400 lumens ,CRI = 80,PF=0.95, ,CCT= 5700K, Efficacy=110 lm/W, THD=10%, constant current electronic driver should be equipped with surge protection upto 2kV

40

-

-

... More
Supply and fixing of recessed PIR Motion Sensor, sensing radius = 2.5 meter

20

-

-

... More
LIGHTNING PROTECTION SYSTEM

-

-

-

... More
Horizontal Run

-

-

-

... More
Supply and fixing of 8mm Aluminium Round Conductor meeting the requirements as per DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) with polyamide conductor holders for flat roof with holding base placed at every 1m, polyamide conductor holder at parapet placed every 0.7m apart, cross universal connectors including 4 hexagonal bolts, expansion pieces at every 20m of the conductor, connectors required for the expansion piece connection etc and with all other accessories for complete installation.

480

-

-

... More
Air Terminals

-

-

-

... More
Supply and fixing of 4 mtr Vertical Air Terminal as per IEC -62305 part-3 & DIN EN 50164-2 with 16mm Al rod tapered to 10 mm Al rod suitable for high wind load with all required accessories including suitable clamps, connectors etc for complete installation.

8

-

-

... More
Supply and fixing of 2 mtr Vertical Air Terminal as per IEC -62305 part-3 & DIN EN 50164-2 with 16mm Al rod tapered to 10 mm Al rod suitable for high wind load with all required accessories including suitable clamps, connectors etc for complete installation.

3

-

-

... More
Vertical Run

-

-

-

... More
Supply and fixing of 8mm Aluminium Round Conductor meeting the requirements as per DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) with necessary conductor holders with holding base placed at every 1m, test joints suitable to connect 8mm round conductor with 30x3 mm GI earth strip etc and all other required accessories for complete installation.

260

-

-

... More
Earthing System

-

-

-

... More
Supplying and fixing of 30x3 mm GS flat strip with zinc coating of 500gm/sq.m (70 micron min) tested for lightning protection system and as per DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) with necessary cross connector, spacer clip,plastic corrossion protection strip, clamps etc with all required accessories for complete installation

500

-

-

... More
Supply and fixing of CPRI tested maintenance free ,low carbon copper coated earth electrode of 3 metre having diameter of 14.2 mm withcopper coating thickness of 250 micron and tested as per IEC 62561-2 with necessary clamps, chemical compound (IEC 62561-7), Polypropylene & Polyethylene (UFE) Inspection Chamber with heavy duty cover of dimension 300x300mm (weight bearing capacity of 50kN) and with all accessories required for complete installation.

6

-

-

... More
Miscellaneous

-

-

-

... More
Supply and erection of vertical and horizontal type cable trays and cable supports fabricated out of MS angles (ISA) and MS flats with sufficient width and spacing between successive cross members and supported at adequate spacing. The cable trays and supports shall be painted with two coats of Zinc Chromate primer and two coats of enamel paint. (Size as specified by Technopark as per site conditions)

750

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with black finish with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

450

-

-

... More
750 mm width X 62.5 mm depth X 2.0 mm thickness

10

-

-

... More
900 mm width X 62.5 mm depth X 2.0 mm thickness

10

-

-

... More
Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.

351

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

132

-

-

... More
Earthing with G.I. earth plate 1200 mm x1200 mm x 12 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with all accessories as required.

15

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

250

-

-

... More
SITC of 10kVA, 3-phase pure sine wave inverter with 2 nos of 150AH Tubular Battery, Stand etc with all accessories.

1

-

-

... More
Supply of CO2 Extinguisher 4.5Kg, Fire rating of 55B, PESO approved Aluminium cylinders with CCOE certification, IS 15683:2018 standard, Certifications from BIS, EN, CE, ISI and date of manufacture imprinted on cylinder, coated with High Glossy PU Paint, anti corrosive make, Discharge hose with the conductive wires to dissipate the static charge generated during CO2 discharge, Carbon dioxide gas having a purity of 99.5% and conforming to IS15222, “D” handle for ease of carrying and operator safety, Cold impact extrusion can, Used-Unused Mechanism, Squeeze Grip, Gross Weight 11.16 Kg, Empty Weight 6.66Kg, Can Height 860mm, Diameter 140mm, Discharge time minimum 8 Seconds, Controllable discharge mechanism, Range minimum 2m, two piece floating spindle valve with a handwheel to operate, venyl sticker/label with all the details including operational instructions, 10 years warranty

6

-

-

... More
Supply and providing 3.3kV, 2mm thick synthetic type and 1 m wide electrical grade chequered type mat confirming to IS 15652 (2006)

30

-

-

... More
Supply and providing 11kV, 2.5mm thick synthetic type and 1 m wide electrical grade chequered type mat confirming to IS 15652 (2006)

20

-

-

... More
Supplying, Fixing First Aid Chart duly framed and placed in a conspicuous location for clear vision.

1

-

-

... More
Supplying and Providing 15" long rubber hand gloves 15 kV

2

-

-

... More
Supply & fixing neatly laminated electrical schematic drawings on good frame work.

1

-

-

... More
Preparation of all drawings submitting and getting approval and Sanction for Energisation from Kerala State Electrical Inspectorate by a Licensed A Class Electrical Contractor for the electrification of proposed commercial building, load additions and modification works which includes current additions in the existing RMU network, submitting of Completion certificates and arranging inspection, getting sanction and energization certificate etc., providing and fixing neatly Laminated Electrical schemes and layout for Commercial building .

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.