Harbour Engineering Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HED_683801_1Tender No
HED/CEHED/TR/1034/2023_6_1_1/1Tender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
2
-
-
1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
15
-
-
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
30
-
-
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
20
-
-
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
34
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
60
-
-
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
100
-
-
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
4
-
-
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
4
-
-
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
4
-
-
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
4
-
-
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
3
-
-
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
6
-
-
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
8
-
-
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2
-
-
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
8
-
-
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
18
-
-
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
4
-
-
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
22
-
-
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
3
-
-
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
1
-
-
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
4
-
-
OD3279/2024-2025:Supply and fixing IP 65 HENSEL 1 row 9 module( Model No KV 7109) KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws.
1
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
38
-
-
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
31
-
-
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
8
-
-
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
8
-
-
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
3
-
-
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
8
-
-
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
1
-
-
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2
-
-
5.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
6
-
-
5.5:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
2
-
-
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
3.5
-
-
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
32
-
-
5.19:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
64
-
-
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
299
-
-
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
136
-
-
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
10
-
-
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
10
-
-
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2
-
-
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
2
-
-
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
168.75
-
-
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
2.2
-
-
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
7
-
-
14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
6
-
-
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
3
-
-
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1
-
-
90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
152
-
-
90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2
-
-
OD3283/2024-2025:Supplying and fixing of surface/ recess mounting, vertical type, 415 volts,Dust and waterproof ,IP66 Hensel make or equivalent FPVN 0811 opaque door( 8 + 24 way) VTPN poly carbonate distribution board , with provision for MCCB as incomer .
1
-
-
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
1008
-
-
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2
-
-
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
300
-
-
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
155
-
-
90.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
100
-
-
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
45
-
-
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
25
-
-
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
10
-
-
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
30
-
-
90.12.39.32:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
20
-
-
90.12.41.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
5
-
-
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
1140
-
-
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
3
-
-
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
2
-
-
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
6
-
-
OD3696/2023-2024:Supply Installation testing and commissioning of Gate pillar post light with lamp .The fixture have maximum height of 35cm made of cast aluminum base with brass holder, weather proof, perfect for outdoor application IP44 rated and suitable for fixing LED on existing on gate pillar preferred make Philips Model No.: 15402/86/16 or equivalent.
26
-
-
OD3697/2023-2024:Fabricating, supplying, conveying, lifting and erecting tubular post of height of 2m using 65mm Heavy duty G.I. Pipe having ISI mark and of approved quality as per the drawing, erected on a RCC 1:2:4 foundation in 2 Nos well steining of 0.3m depth and 0.75 m dia. and a muffing of 0.45x0.45m with height 0.60m. The post shall be erected on 4 numbers of 16mm dia GI foundation bolts of length 1m having 100mm long standard thread with a 12mm thick GI flange of OD 125mm and ID 65mm at the bottom of the post with 4 nos of 16mm bolt holes and 3Nos of 16mm nuts per bolt. The post is to be painted with two coats of industrial marine epoxy primer and two coats of best quality synthetic enamel paint of approved make and colour. Muffing to be plastered using cement mortar 1:4, 12mm thick colour washing 2 coats using approved colour etc. complete .All GI pipe sections to be used for the fabrication of the post shall be of TATA/ZENITH/APOLLO make .All steel items shall be dip galvanised.
7
-
-
OD3698/2023-2024:Supply and fixing of LED Post top equipped with the second generationLensoFlex2® photometric engine with futureproof technology for on site module replacement, offering a high-performance photometry. The luminaire shall have 32 LED driven at not more than 700mA. The average power consumption shall be 40W. The LED’s shall be of neutral white. The luminaire shall have IP 66 optical compartment sealed by an extra-clear glass protector for an optimal luminous flux. The control gear compartment shall have IP 66 tightness level. The luminaire shall be made of aluminium die cast materials. The glass protector should have IK 08 impact resistance. Each LED should be associated with a specific lens that generates the complete photometric distribution of the luminaire. 90% lifetime residual flux @ 60,000 hours at Ta 35degree.The luminaires shall have direct access to gear and electronic compartment, Surge protection up to 10kV. The standard body colour shall be of RAL7037. Or equivalent
2
-
-
OD3699/2023-2024:Supply, erection and commissioning of LED display board 230 V, single phase AC, 50 Hz,outdoor type, visible at a distance of 100m and in red/yellow colour on existing pipe.. The letters should be raised by at least 5 cm so that, it is visible when LEDs are OFF in day time. The board shall be waterproof with IP 65 protection. The rate is inclusive of specified design in the display board with fixing clamp ,connection etc complete as required
5.08
-
-
OD3700/2023-2024:Supply and fixing of LED Bollard 9W, a Mild Steel Painted Cadmium Ø 140mm cylindrical pipe of total height 1000mm, with Frosted Acrylic protector sealed to make an IP66 optical block, suitable for surface mounting on 4 x M10 Bolt on 180mm PCD, System power (including driver loss) of 10W +/- 10% with Lifetime residual flux L70 @ 50,000 hours at Ta = 50?C, in built surge protection of 4kV (in Differential and Common mode), Power Factor > 0.95, IP 67 LED Driver, Colour Rendering Index > 80 and CW Light. The column should be painted with 2 coats of UV resistant, sandblasted and marine grade paint complete as required. Preferred make bajaj BGBOL 10009W LED WH or equivalent
10
-
-
OD5611/2023-2024:Supply Installation testing and commissioning of 9W High Efficacy LED Step Light, with high efficacy LED driver, made of aluminum body perfect for high pedestrian traffic and plant life ,outdoor application. CCT 5700K. Luminaire with nominal voltage of 240V, 50Hz and lumens of 100lumen. Ingress protection of IP 66 or above to prevent from dust & moisture. Including all fixing accessories complete as required preferred make Philips or equivalent
10
-
-
OD3702/2023-2024:Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
417
-
-
OD3705/2023-2024:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 6 sq. mm
22
-
-
OD3724/2023-2024:Supplying and making end termination nickel plated single compression brass cable gland for 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
84
-
-
OD3727/2023-2024:Supply and laying bare earthing conductors of 3.15 mm copper conductor (10 SWG) laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in Ordinary soil).
18
-
-
OD3730/2023-2024:Supply and fixing Cable Junction Boxes IP 66 for outdoor applications( with metric knock outs for cable entry - Black Color)) suitable for cable sizes up to 16/25 sq.mm, 200 X 160 X 98 mm Hensel model No KF 5255 or equivalent and accessories for Cable Junction Boxes such as Terminal Set 2.5 sq.mm / 4 sq.mm including giving necessary connections, making good the damages etc. as required.
7
-
-
OD3191/2024-2025:Supply and fixing Cable Junction Boxes IP 67 for outdoor applications (with knock outs for cable entry - Black Colour) suitable for cable sizes 2.5 sq.mm ,88 X 88X 53 mm Hensel model No KF 5025 B or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
30
-
-
OD3735/2023-2024:Engaging labourers for dismantling the existing DB, electrical fittings, accessories etc., keeping the same safely and restoring the surface neatly. as per the instruction form the departmental officers at site . Beldar/coolie
4
-
-
OD3736/2023-2024:Engaging labourers for dismantling the existing DB, electrical fittings, accessories etc., keeping the same safely and restoring the surface neatly. as per the instruction form the departmental officers at site. Wireman
4
-
-
OD3746/2023-2024:Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 840 T8 API Philips or equivalent
17
-
-
OD3754/2023-2024:Supply and fix LED Bulk Head fitting 10W with Aluminium die-cast housing and polycarbonate optic materials including connection etc as required. The luminaire shall have IP66 protection, luminous flux 1000 lm, luminous efficiency 100 lumens/watt, cool daylight colour and 6500k colour temperature PHILIPS WT110 VistaGlow essential Bulkhead or equivalent
4
-
-
OD3755/2023-2024:Supply and fixing 7/9 W LED ,BC, lamp OSRAM or equivalent
30
-
-
OD3757/2023-2024:Supply, fabrication, conveyance and fixing of 40 mm dia Medium class GI pipe with clamps made from 20 x 3 mm MS flat bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
14
-
-
OD5660/2023-2024:Supply and installation of decorative classic LED street lantern of system wattage of 40W, BIS certified with body made of cast and spun aluminum, permanently sealed optical block (IP66) with heat sink and PMMA protector (IK07) fitted with a Vent Plug pressure equalization unit, fixed onto a hinged spun luminium frame, control gear compartment accessed by loosening one screw for tool free opening and closing. Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overall system efficiency of 120lm/W at correlated color temperature (CCT) of 3000K/4000K, colour rendering index (CRI)70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 KV ,preferred Make Kesselec VALE or equivalent
4
-
-
OD5661/2023-2024:Supply and installation of Decorative Pole 4 meter height above the ground level made out of GI and cast iron embellishments, having two section, bottom section of minimum 1000mm length with base dia of 114mm following with base made up of cast iron providing aesthetic pleasing having dia of 145mm and upper section of minimum 3000mm with dia of 76mm. The Pole shall have a cast iron reducer at the bottom of upper section joining with base section. The pole shall have base plate of dimension 200x200x12mm and with 4 Nos foundation bolt slot. The pole shall be with inbuilt junction Box and connectors for loop in loop out. The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Design comply EN40 standard and basic wind speed 169kmph.Pole should hot dip galvanized after 7 tank process to 65 microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coats of epoxy primer and above that it should be given with polyurethane UV resistant coating painted with avg. DFT of 100micron. The complete system should be hot dipped Galvanised and marine grade treated. CAT REF: KESSLEC 4M HDGI RILA POLE WITH BASE PLATE
4
-
-
OD3758/2023-2024:Supply, installation, testing and commissioning of 230V AC. 50HZ , 1.5 KVA inverter having digital frequency control circuit with on load automatic changeover from mains to inverter circuit on mains failure and vise versa on restoration of mains supply . The unit shall have an in-built battery charger with solar charging option of suitable capacity having automatic cut off circuit on battery attaining full charge . The unit should also have overload trip with audio visual indication & automatic reset on removal of overload, LED indication for Mains ON, charging ON, Overload Trip & inverter ON and Output ON/OFF switch on the front panel .Preferred make LUMINOUS / APC /MICROTEK.
1
-
-
OD3759/2023-2024:Supply and installation of Inverter battery 12V 100 Ah tubular type conforming to ISO 9001:2008 and ISO 14001:2004 suitable for 3hours backup on full load .Preferred make of EXIDE / LUMINOUS / AMRON with suitable battery rack, interconnection complete as required
2
-
-
OD3761/2023-2024:Supply and fixing 63A to 100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL with with BUC rotary drive kit in the existing meter board/panel board termination interconnection with suitably rated copper wire complete as required.
1
-
-
OD5514/2023-2024: Fabricating, supplying, erecting and commissioning of wall mounting, fully compartmentalised, dust and vermin proof cubicle panel board of size 1100x1500x250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality synthetic enamel paint over two coats of epoxy primer of approved quality, having front openable bolted type vertical bus bar chamber & cable alley covers with cable entry provisions and bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top. The panel should have 75x40x6.0mm MS channel provided at the bottom as support and comprising the following(Panel drawing attached with the schedule) Incomer: 63 A, 4 Pole, 415 Volts AC : AC23A duty ON LOAD COS with handle-1 No Incoming:- 63A, 25kA FP MCCB setted to 50 A and rotory drive kit including BUC handle - 1No Outgoing : 40A, 25 kA , 4 Pole, MCCB with rotory drive kit including BUC handle and - 1No Outgoing : 40A, 25 kA , 3 Pole, MCCB with rotory drive kit including BUC handle and - 1No Outgoing:-25A, 25kA TP MCCB setted to 20A with rotory drive kit including BUC handle -3Nos All switches and MCCB should be of panel mounting and conforming to IS:13947part III (L&T/SIEMENS/Legrand) 32A two way disconnectable type neutral link-4nos ,Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper c onductors ELR with CBCT current setting 0.03 A to 1A with delay time setting 0.3 to 3 sec - 1 No 230v ac shunt release suitable for 63A MCCB -1NO .Metering and Indication:- 3Nos 50/5 A tape wound CTs,415V ac, 50Hz, 3LINE LED Multi Function Meter (Schneider or Equivalent)- 2 No.,22.5mm dia LED type indication lamps for three phases(R,Y &B) - 2 set and control Group B 2A SP MCB (C Curve)-6 numbers inside the cubicle. The panel board should have hinged shutters for MCCB cubicles and front openable bolted type busbar covers with quarter turn type lock and key arrangement and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 25x3mm copper strip with two earthing points brought out at bottom side. (Panel drawing attached with the schedule)
1
-
-
OD2895/2024-2025:Supply and providing 6Kg stored pressure ABC Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
1
-
-
OD2924/2024-2025:Supply and Fixing 9 litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint "FIRE" mounted on MS angle frame work/wall bracket fillled with fine sand, painting the frame work/floor stand including making good the damages, colour washing etc.as required.
2
-
-
OD2896/2024-2025:Supply and providing Chequered Electrical Rubber Mats, Thickness 6mm (Black, 1 Mtr X 2 Mtr) Insulating Rubber Mat, Anti – Skid, Shock Proof must withstand 3.3 KV dielectric strength conforming to IS 15652/2006
2
-
-
OD2897/2024-2025:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision
1
-
-
OD2920/2024-2025:Supply of factory made CAT-6, 1 mtr patch cord suitable for RJ 45 Socket for Personal Computer complete as required.
2
-
-
OD2921/2024-2025:Supplying and fixing Cat 6 RJ 45 computer socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
2
-
-
OD2922/2024-2025:Supplying and fixing Cat 6 RJ 45 Frame on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
2
-
-
OD2925/2024-2025:Identifying the CAT6/Telephone cable and the termination the end with male connectors/ existing sockets using special crimping tools complete as required.
6
-
-
OD2923/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
24
-
-
OD3065/2024-2025:Supply, Installation, Testing, and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required: a) Solar Photovoltaic Module of capacity 330 Wp or above, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730- Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories, etc. as required. e) Lightning and surge voltage protection including earthing f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, a main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. g) Statutory fees such as KSEB Fees (Application Fee, Registration fee & Liasioning Fee),Electrical Inspectorate Liasioning Fee, Net meter - (Including Testing/Calibration Liasioning Fee) etc are to be paid by the contractor as part of this work.
10
-
-
OD3096/2024-2025:Supply and fixing LED Bush light. The luminaire is provided with 9W high efficiency LED landscape luminaire with high efficiency drivers designed to provide directional spot.
2
-
-
OD3196/2024-2025:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
70
-
-
OD3197/2024-2025:Supply and drawn 10 HDMI cable to connect NVR to LED TV.
1
-
-
OD3198/2024-2025:Supply and fixing Floor Mount 9U Rack for switches for NVR including , AC Distribution box(x1), fan (x1) Closed type cable manager and hardware mounting kit Recommended: Legrand/Netrack.
1
-
-
OD3199/2024-2025:Supply, installation, testing and commissioning of 4 MP IP Full-color Fixed-focal Bullet/Dome Network Camera having following minimum specifications: 4MP, 1/3" CMOS image sensor, low illuminance, high image definition, Outputs 4MP (2560 × 1440) @ 25/30 fps, Max. supports 4MP (2688 × 1520) @ 20 fps, H.265 codec, high compression rate, ultra-low bit rate, ROI, SMART H.264+/H.265+, flexible coding, applicable to various bandwidth and storage environments, Rotation mode, WDR, 3D NR, HLC, BLC, digital watermarking, applicable to various monitoring scenes, 12V DC/PoE power supply, IP67 protection etc. Warranty: 3 years, Recommended Model: Dahua/eqvt.
2
-
-
OD3200/2024-2025:Supply, installation, testing and commissioning of 8TB SATA 6Gb/s HDD for video recording inside the existing NVR. The drive should have 24x7 reliability, Reduced power consumption, Whisper quiet, Compatible, AF Technology etc. Recommended Make: WD Purple/Seagate/Toshiba
1
-
-
OD3201/2024-2025:Supply, installation, testing and commissioning of 16-Port Gigabit Layer 2 PoE Switch with PoE Budget, Port 1–2≤90W, Port 3–16≤30W, total≤190W, Switching Capacity- 52 Gbps, MAC Table Size- 8K, Standards Compliance- IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3ab, IEEE802.3z, PoE Standard- IEEE802.3af, IEEE802.3at, Hi-PoE, IEEE802.3bt, 100BASE-TX/1000BASE-T Interface conforming to FCC Class A, CE Class A Emission, RoHS compliant.Warranty: 3 Years Recommended Make: Dahua/eqvt.
1
-
-
OD3202/2024-2025:Supply installation testing and commissioning of 4K 16 Channel Network Vedio Recorder having following specification : Network Bandwidth Access: 160 Mbps; Storage: 160 Mbps; Forward: 64 Mbps, Resolution- 8MP; 6MP; 5MP; 4MP; 3MP; 1080p; 720p; D1 . Decoding Capability- 8 × 1080p@30 fps, HDD- 2 SATA III ports, up to 10 TB for a single HDD Video Output- 1 × VGA output, 1 × HDMI output, supports simultaneous video sources output for VGA and HDMI. Video- Smart H.265/H.265/Smart H.264/H.264/MJPEG Audio- PCM/G711A/G711U/G726/AAC , Network Protocol- HTTP; HTTPS; TCP/IP; IPv4/IPv6; UPnP; SNMP; RTSP; UDP; SMTP; NTP; DHCP; DNS; IP Filter; DDNS; FTP; Alarm Server; IP Search (Support Dahua IP camera; DVR; NVS; etc.); P2P; auto register, Mobile Phone Access Android; iOS, ulti-channel Playback- Up to 16 channels for playback, External Port- Audio Input- 1 × RCA input, Audio Output- 1 × RCA output, USB- 2 (1 × front USB2.0; 1 × back USB2.0), HDMI- 1 (supports up to 4K resolution output), VGA- 1 No, Network- 1 × RJ-45, 10/100/1000 Mbps self-adaptive Ethernet port, Certifications- CE: EN62368-1; EN55032,EN55024, EN55035, EN61000-3-2, EN61000-3-3 EN50130-4 FCC: Part 15 Subpart B. Warranty: 3 year warranty Recomended Make: Dahua/UNV/Panasonic
1
-
-
OD3204/2024-2025:Supply and installation of 43 inch Android TV with necessary cables and accessories for monitoring.
1
-
-
OD3281/2024-2025:Supply and installation of 12W IP68 Waterproof LED Underwater Light,certification: ce, RoHS, ccc, features: LED underwater light, protection level: ip68,
2
-
-
Civil Work
-
-
-
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5
-
-
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
100
-
-
14.54.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work
3
-
-
Public Address System
-
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
100
-
-
90.6.5.4:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm
300
-
-
OD5656/2023-2024: Supply, installation, testing and commissioning of PA power Amplifier of 300W Max., 250W 250 W with Built-in Digital Player having following minimum specifications: Input Power supply: Power Supply AC: 220-240V 50/60Hz DC: 24V, Power Output 300W Max., 250W RMS at 10% 6 Mic & 2 Aux Inputs, Built-in MP3 player with remote control for USB, SD/MMC card reader, Frequency Response: 50-15,000Hz ±3dB, Tone Controls: Bass: ±10dB at 100Hz, Treble: ±10dB at 10kHz, Speaker Output: 4Ω, 8Ω, 70V & 100V, Recommended Model: AHUJA SSA 250 DP/ Studiomaster / eqvt.
1
-
-
OD5655/2023-2024:Supply, installation, testing and commissioning of Wall mount speaker 30 Watts 2-Way Compact PA Wall Speakers with Subwoofer .Ahuja Wall Speaker ASX-312B (30 Watts 2-Way Compact PA Wall Speakers) Black or equivalent Ahuja Wall Speaker ASX-312B () Black
8
-
-
OD5653/2023-2024:Supply and fixing Floor /Wall Mount 9U Rack suitable for for PA Amplifier including AC Distribution box(x1), hardware mounting kitRecommended: Legrand/Netrack.
1
-
-
OD5652/2023-2024:Supply, installation, testing and commissioning of High Quality paging microphone having 50 - 15000 Hz frequency response, 600 Ohm impendence & 2.5mV/Pa sensitivity with strong , robust and stable base incorporate separate push switches for momentary and locked use. It should have flexible 10" goosneck security fixed to the aluminium die-cast base. Recomented: ACM 96 or Equivalent
1
-
-
OD5651/2023-2024:Supply of Audio Auxiliary cable with suitable Connector at both end for connecting Audio output of Laptop/Audio equipment to connecting PA Amplifier make SeCro Laptop 6.35mm (1/4 inches) Male Mono Plug to 3.5mm Male Stereo Audio Jack Cable -16.4FT [5 Meters] Black or equivalent
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements