Bharat Sanchar Nigam Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 19,005Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_215217_1Tender No
KRLCO-13/16(11)/61/2024-ELECTTender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://https://www.bsnl.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling DB, after Disconnecting all incoming and outgoing cables / conduit wirings connections, earthing connection, etc and shifting the dismatled DB to a convenient place within the exchange premises as per the direction of engineer in charge without causing damage to the building and equipment etc complete as required.
10
-
-
Dismantling DC DB after Disconnecting all incoming and outgoing cables / conduit wirings connections, DC light point along with the wiring etc and shifting the dismatled materials to a convenient place within the exchange premises as per the direction of engineer in charge without causing damage to the building and equipment as required.
7
-
-
Dismantling AC units control panel after dismntling all incoming and outgoing cables / conduit wirings connections etc and shifting the dismatled materials to a convenient place within the exchange premises as per the direction of engineer in charge without causing damage to the building and equipment as required.
7
-
-
Dismantling power circuit wiring for AC units in surface/recess metal / PVC conduit including dismantling industrial sockets, plug stations, DP isolators etc and shifting the dismantled materials to a convenient place within the exchange premises as per the direction of engineer in charge without causing damage to the building and equipment as required.
30
-
-
Dismantling light/power/DC emergency /AFDS wirings (in one room ) in surface/recess metal / PVC conduit including dismantling switch boards, fittings, detectors etc and shifting the dismantled materials to a convenient place within the exchange premises as per the direction of engineer in charge without causing damage to the building and equipment as required.
40
-
-
Dismantling 2 core/3.5 core /4 core armored aluminium cable of size up to 120 sqmm including shifting the dismantled materials to a convenient place within the exchange premises as per the direction of engineer in charge without causing damage to the building and equipment as required.
300
-
-
Dismantling oil / Air cooled SCVS up to 100 KVA after Disconnecting all incoming and outgoing cable connections etc and shifting the dismantled SCVS to a convenient place within the exchange premises as per the direction of engineer in charge without causing damage to the building and equipment as required.
1
-
-
Dismantling a KSEB meter board after disconnecting all incoming and outgoing connections etc and shifting the dismantled meter board to a convenient place within the exchange premises as per the direction of engineer in charge without causing damage to the building and equipment as required.
7
-
-
Dismantling following items in fire alarm system including disconnecting electrical connections and shifting the dismantled items to a convenient place within the exchange premises as per the direction of engineer in charge without causing damage to the building and equipment as required.
-
-
-
Fire alarm panel upto 8 zone
7
-
-
Dismanling the outdoor and indoor unit of 1.5 TR Split Type AC unit, dismantling all electrical and mechanical connections, refrigerant pipes, prefab stand etc without making any damages to the unit and the building, shifting and stacking the 1.5 TR Split type AC unit at the building premises as per the direction of engineer in charge etc as reqd.
30
-
-
PART-B-REFIXING
-
-
-
Fixing 3 compartment KSEB meter board at new location on the wall with suitable fasteners including liaison work with KSEB , giving necessary electrical and earthing connections etc complete as reqd. [Any payment to KSEB on the account of shifting of the meter board will be reimbursed by BSNL on submission of KSEB receipts]
5
-
-
Supply and fixing the following items in existing KSEB meter borad / DB i/c giving nescessary interconnections, testing and commissioning etc complete as required
-
-
-
63 A 4pole 300 m A ELCB
4
-
-
Porcelein Kit Kat fuse unit of 100 Amps capacity
10
-
-
Neutral Link
5
-
-
S/F 50 mm dia PVC pipe with accessories like bend, socket for service connection including necessary supports, clamping etc as required.
20
-
-
Fixing the existing 125 A 4 pole change over switch on wall / existing panel with suitable fasteners including providing necessary electrical and earthing connections etc complete as reqd.
5
-
-
Supplying and laying one number PVC insulated and PVC sheathed/ XLPE armoured Aluminium power cable of 1.1KV grade ofsize 4 C 25 sq.mm on surface/loose inside the panel/in existing pipe/direct in ground etc complete as reqd .
100
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
4 x 25 Sqmm
30
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
80
-
-
S/F of following size of steel conduit along with accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit etc as reqd ( For AFD wiring)
-
-
-
20mm
70
-
-
S/F of following size of medium class PVC conduit along with accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit etc as reqd
-
-
-
20mm
300
-
-
25mm
70
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
2X1.5 Sqmm
125
-
-
3 x 1.5 Sq mm
150
-
-
4X1.5 sqmm
50
-
-
6 x 1.5 Sq mm
50
-
-
3 x 2.5 Sq mm
70
-
-
3 x 4 Sq mm
50
-
-
Fixing the dismantled industrial socket/ DP isolator with enclosure/ DP Changeover isolator including interconnection etc complete as required.
7
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
-
-
-
Group C
20
-
-
Providing suitable size hole on wall for fixing 12" exhaust fan including cutting the wall,neatly plastering, colour washing etc complete as reqd.
6
-
-
Fixing of exhaust fan with louver including replacing capacitor , oiling, giving connection, testing and commissioning etc as reqd.
6
-
-
Supplying and drawing 25 Sqmm ABC Aluminium weather proof cable ( 4 core + 1 GI stay wire ) from EB post to Meter board i/c tieing / fixing at both ends with suitable fastners , pdg connections testing etc as required.
40
-
-
ITC of following items on wall /ceiling including rearranging existing conduit wiring/ cabling for AFDS as per the direction of engineering incharge etc complete as reqd.
-
-
-
Fire alarm panel upto 8 zone
7
-
-
Detectors with metal box
21
-
-
MCPs
14
-
-
Hooter / Siren
14
-
-
Rerouting the existing 2 core/3.5 core/4 core armoured cables of size up to 70 Sq mm on surface of wall including dismantling the cable from wall / duct , providing end termination with brass compression gland and aluminium lugs,giving connection etc complete as reqd.
150
-
-
Supplying and fixing PVC batten/ angle holder with 12 Watts LED bulb including supply and fixing suitable Round bock, connections, testing, commissioning etc. as required.
10
-
-
Supply and fixing digital temparature controller with range approx 20-40 degC with 4A potential free contacts working on 230V a.c. supply to operate one exhaust fan in suitable size PVC box i/c giving necesssary inter connection etc as reqd. ( SUBZERO- 7510/ 7569P/ TM&W or similar make. Model to be selected with approval of Engineer in charge.)
5
-
-
Supply and fixing 12" ,230 V 50 Hz 1350/1400 rpm heavy duty exhaust fan with louver assembly including giving connection testing, commissioning etc as required. (Fan Make M/s Almonard or SS make)
5
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5
-
-
RDSO approved Chemical earthing for Equipment earthing /lightning conductor with earth electrode made of high tensile low carbon steel circular rods, molecularly bonded with copper on outer surface to meet the requirements of Underwriters Laboratories (UL) 467-2007 or latest or IEC 62561 having high tensile strength of not less than 50kg /m2 , high corrosion resistant strength, by digging and filling Earth enhancement compound together with back fill soil as per specification i/c providing masonay enclosure with cover plate etc. .(M/s CAFE or any RDSO approved Make)
2
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
25
-
-
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia GI pipe from earth electrode including connection with GI nut, bolt , spring washer , excavation and refilling etc as required
40
-
-
Supplying and fixing GI earth bus bar of size 300X50x10 mm size on suraface of wall with suitable insulators for mounting etc as reqd
3
-
-
Supplying and fixing step type electronic regulator for ceiling fan in the existing switch box / cover including connection,removing old regulator etc as required.
4
-
-
Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket,bend,couplers etc confirming to IS 14930 ,Part II complete with fitting and cutting ,joining etc direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc complete as reqd
-
-
-
63 mm dia(OD-63mm&ID 51mm nominal)
30
-
-
Supply and providing necessary termination box made out of 16 Guage MS sheet including providing its knock outs, suitable welding, drilling holes, grinding, painting etc including providing necessary bolt for fixing the cover etc as required.
1
-
-
Supply and fixing hinged door type SMC box of nominal size 65 cm x 35 cm x 21 cm on wall suitable for fixing 3 phase KWh meter including liaison work with KSEB , giving necessary electrical and earthing connections etc complete as reqd. [Any payment to KSEB on the account of shifting of the meter board will be reimbursed by BSNL on submission of KSEB receipts]
2
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
70
-
-
Supplying and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch on the existing switch board, including making necessary cutting on the phenolic laminated sheet, giving connections etc. as required.
7
-
-
Supplying and fixing 3 pin 5/6 A socket outlet on PVC box of 100mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing connections, painting etc. as required. (For wall Fan)
7
-
-
Supplying and fixing 400 mm sweep wall fan suitable for 230 V 50 Hz AC supply as required (M/s Bajaj Midea/superior make)
3
-
-
Supply and fixing 20 W LED retrofit tube suitable for 230 V 50 Hz AC supply in the existing M/O fitting including providing minor modification in the wiring ,testing commissioning etc as reqd.
7
-
-
Reinstallation of 1.5 TR Split type AC unit including refixing the existing pre fabricated stand, Refixing the existing refrigerent pipe with cable , providing necessary insulation over refrigerent pipings, pressure testing vacuumising , gas topping up,connection and testing etc complete as required
5
-
-
S/F of copper refrigerant line combined suction/discharge pipe of required size, making thermal insulation with poliform sheet/ tube to extend the additional length as required
20
-
-
Gas charging of 1.5TR S/T AC unit with R-22 / A 407/ R- 32 etc refrigerant gas etc as required.
4
-
-
Fixing of 32 Ampere to 125 Ampere TPN switch (dismantled old item) in existing panel with suitable fastners , pdg connections testing etc complete as required.
5
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
6 way (4 + 18), Double door
2
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
-
-
-
4 way (4 + 12), Double door
6
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
6 way, Double door
2
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker/isolator suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole MCB
20
-
-
2pole 32A MCB
1
-
-
Triple pole 32A MCB
5
-
-
4 pole, 415 volts, 63 Amps Isolator
7
-
-
Supply and fixing 1200mm BLDC 1200mm ceiling fan with remote control on existing fan hook, providing connection with 1.5 sqmm Cu cables etc complete as reqd (Make Crompton )
3
-
-
Supplying and fixing surface/suspended type 4 ft LED integrated batten fitting withfire retardent extruded plastic/metal frame with maximum power input of 20 W and with lumens output not less than 1800 lumens suitable for 240V,50 Hz AC supply , giving connections, testing, commissioning etc. required (Philips Smart bright or Sup. Make)
15
-
-
Providing Rain Guard arrangement for meter board including supply and fixing following Items, providing necessary clamps, tar washers etc for fixing the roofing sheet, painting the iron parts etc complete as reqd
-
-
-
25x25x5 mm MS angle Iron
12
-
-
25x 5 mm MS flat
8
-
-
0.35 mm Corrugated colour coated GI Sheet
4
-
-
S/F of SMC box of 195mm x 140mm x 65mm deep with 8 way connector for terminating the alarm cables etc complete as reqd.( make : sintex ,GSJB 1510)
4
-
-
PART C : SHIFTING OF DISMANTLED ITEMS
-
-
-
Transporting of all the dismantled items from vacated rooms of TE building (Except Engine Alternator set with Accesseries) to the nearby Dept TE buildings within 50 Km Distance without making any damage and stacking the items as directed by Engineer in charge in exchange premises/rooms, loading ,unloading etc complete as reqd.
7
-
-
Dismantling and shifting of existing Engine Alternator sets upto 63 KVA with control panel with support work, Diesel tank with support work , residential type silencer along with support pipe, Exhaust pipe from EA set to outside of the wall,including disconnecting outgoing cables , diesel pipe lines , loading the EA set using crane/ chain pulley , transportation of the EA set along with accesseries to the nearby Dept TE buildings within 50 km distance , including unloading the EA set without making any damage stacking the items as directed by Engineer in charge in exchange premises/rooms etc as required.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%