Rural Drinking Water And Sanitation Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Drinking Water And Sanitation Department Tender

Electrical and Electronics
Electrical Works
Opening Date18 Jul 2024
Closing Date26 Jul 2024
Tender Amount₹ 9,32,001.5 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Supplying and fixing PVC/metal conduit Deep junction box,32 mm deep Junction box

51

24

1224

... More
code05 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. a) 6 Amps one way Switch

88

35

3080

... More
code06 - b) 6A Three Way socket

162

8

1296

... More
code07 - c) Stepped Fan Regulator Two Module

313

4

1252

... More
code08 - d) 32A DP Switch

326

6

1956

... More
code09 - e) 6/16A Universal Socket

236

6

1416

... More
code10 - f) 16A Three Pin Top

110

1

110

... More
code11 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. a) Short point upto 3Mtr from tapping point to out let via switch

251

18

4518

... More
code12 - b) Medium point above 3Mtr upto 6mtr from tapping point to outlet via switch

361

16

5776

... More
code13 - c)Three outlet in a row, above 6m upto 10m from tapping point to out let via switches bo

542

40

21680

... More
code14 - Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.

3750

7

26250

... More
code15 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.

105

25

2625

... More
code16 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete, a) 3 Way

124

4

496

... More
code17 - b) 6 Way

173

3

519

... More
code18 - c) 16-18 Way

225

4

900

... More
code19 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. a) 1-2 Way

138

4

552

... More
code20 - b) 6 Way

220

4

880

... More
code21 - c) 10-12 Way

319

3

957

... More
code22 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. a) 1-2 Way

161

4

644

... More
code23 - b) 6 Way

231

4

924

... More
code24 - c) 10-12 Way

344

3

1032

... More
code25 - Wiring for lighting/power circuit using one of FR PVC insulated 1100V grade, multistrand Copper conductor single core cable in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP of GROUP - a). 1.5 sqmm

26

950

24700

... More
code26 - b). 2.5 sqmm

42

2600

109200

... More
code27 - c) 4 .00 Sq mm

63

450

28350

... More
code28 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.a) 6-32Amps SP

415

30

12450

... More
code29 - b) 40 Amps DP

1060

15

15900

... More
code30 - c) 6-32 A TPN

1717

23

39491

... More
code31 - d) 40 A TPN

3044

18

54792

... More
code32 - e) 50-63 A TPN

3088

5

15440

... More
code33 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. a) 6 Way SP & N (I - Single Door)

1196

2

2392

... More
code34 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. a) 56" Sweep (1400 mm) Regular mode

3031

3

9093

... More
code35 - Supplyingwallmountingfansuitabletooperateatsingle-phase230v AC. supply. 400 mm Sweep

3212

4

12848

... More
code36 - Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.

171

7

1197

... More
code37 - Supplying exhaust fan of 1440 RPM of 300mm(12") size with bracket blades complete for light duty suitable to operate on 230V50Hz, AC Supply.

1492

6

8952

... More
code38 - Fixing one exhaust fan inthenitch alreadyleftinthe wallwith bolts and nuts and5A. Ceilingrose with sufficient lengthof23/0.0076inch PVC insulated twin core wire.

492

6

2952

... More
code39 - Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. a) 15W, 6500 K

326

8

2608

... More
code40 - Supplying of ...feet -PVC Batten with integrated LED tube 22 W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. a) LED light fitting 1 x 4' - 20/22 W

690

8

5520

... More
code41 - Supplyingofrecessmountingnonintegraltype........LEDwluminairecomprisingofpressuredecast/extrudedaluminiumhousing,withspringloadedfalseceilingclamps,PowerLEDswithCCT6500degreeK,CRI70%.efficacy100lumenperW,120degreebeamspread,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.ThelampcompartmentisenclosedwithantiglareopaldiffuserwhichenhancesthelightinglevelLEDsaredrivenbyHFelectronicdriverintegratedinseparatecontrolgearassembly.,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstany manufacturing defect working under standard electrical condition. a) LED modular down light 1'x4' 34-36W

5898

28

165144

... More
code42 - Supply of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lampcompartmentcomprisingofantiglarecleardiffuser with Injectionmould edpolycarbonate/ clearglassmaterial, deliveringsuperiorlightoutput RatedlifeBurning Hrs 50000 hr@ Lumen Maintenance of70%,CCT 5500K,IP66 pticaland electrical compartment &impactresistanceofcomplete luminair e IK08. Power Factor 0.9withmains, Surge Protection Min5KValongwith Over voltage/Overload, shortcircuit /misswiringprotection. Compatible forpolemauling with outerd iaof 40mmto 50mm. Universal Voltage driver to operate wide voltag erange from 100Vto270V50/6 0Hzapplication. Compliance toIS1 0322/ IEC60598, LM79 &LM 80Adh erencewithRo HS.UL approved MCPCB.Topaccessstreetlight withsinglescrew toensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith.......WSystemPowerconsumption.LEDEfficiency1301m/w,nominalCRI 75.Luminairemanufacturershouldhavein-housefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/BodypartWarrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDanufacturer&Cree/Nichia/Lumileds/Osrammake LED Source. .a) LED Streetlight 100W

9486

10

94860

... More
code43 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.

122

44

5368

... More
code44 - Extra length of GI pipe of class B 19mm dia for down rod.

160

8

1280

... More
code45 - Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.

281

7

1967

... More
code46 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.125 A 25 kA

10341

4

41364

... More
code47 - Supplying of on load change over switches 4 poles, AC23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution). 125 Amps

12324

1

12324

... More
code48 - Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. a) 125 Amps

5292

2

10584

... More
code49 - b)100 Amps

5184

2

10368

... More
code50 - c) 63 Amps

3704

4

14816

... More
code51 - Supplying .. A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250 A 4 x 30 x 10 mm Aluminium Strip

3078

2

7695

... More
code52 - Fabricating supplying and mounting MS box made out ..14 SWG. suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. a) 14 SWG.

0.5

18569

9284.5

... More
code53 - b) 14 SWG.

0.5

8569

4284.5

... More
code54 - c) 14 SWG.

0.5

8569

4284.5

... More
code55 - d) 14 SWG.

0.5

12568

6284

... More
code56 - d) 14 SWG.

0.5

9540

4770

... More
code57 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter.

4745

1

4745

... More
code58 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 4 core 95 Sqmm

485

80

38800

... More
code59 - Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)

102

70

7140

... More
code60 - Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.

21

70

1470

... More
code61 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0,75mm dia

245

75

18375

... More
code62 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 4 core 16 Sqmm

150

90

13500

... More
code63 - Supplying tinned copper Lugs and Crimping and Wirring to Terminal point for wire of the following Sizes. a) 16 Sqmm Long Bareel

20

40

800



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.