Rural Development And Panchayat Raj Department Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Rural Development And Panchayat Raj Department - RDPR Tender
Paints and Enamels
Opening Date30 Aug 2024
Closing Date9 Sep 2024
Tender Amount₹ 6,29,925.84
Costs
EMD
₹ 14,880Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
RDPR/2024-25/BD/WORK_INDENT8443Bid Award Id
ViewTender No
RDPR/2024-25/BD/WORK_INDENT8443Tender Authority
Rural Development And Panchayat Raj Department ViewPurchaser Address
-Website
http://https://www.tnrd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
code04 - 11.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges
of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Itm No 11.3 PWD SR 2023-24 VOL 2
2.52
8276
20855.52
code05 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. Itm No 11.26.1 PWD SR 2023-24 VOL 2
939.35
138
129630.3
code06 - 11.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railingwith necessary accessories & stainless steel dash fasteners, stainlesssteel bolts etc., of required size, on the top of the floor or the side of waistslab with suitable arrangement as per approval of Engineer-in- charge,
(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(P-85 , IT-11.28) Common SR 23-24
57.37
565
32414.05
code07 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drop and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Itm No 8.25 PWD SR 2023-24 VOL 2
868.33
137
118961.21
code08 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Itm No 8.30 pg-46 PWD SR 2023-24 VOL 2
384.555
174
66912.57
code09 - 13.34 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (P-123,It-13.34 of PWD Common S.R. of 2022-23) Vol-2
2000
9
18000
code10 - 13.33 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 13.33.2 20 mm nominal dia Pipes (P-122,It-13.33 of PWD Common S.R. of 2022-23) Vol-2
60
217
13020
code11 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P-5,It-2.1 of PWD Electrical S.R. of 2023-24) Vol-6Short point upto 3m from tapping point to out let via switch
3
285
855
code12 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P-5,It-2.1 of PWD Electrical S.R. of 2023-24) Vol-6Medium point above 3m upto 6m from tapping point to out let
via switch
6
394
2364
code13 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P-5,It-2.1 of PWD Electrical S.R. of 2023-24) Vol-6Long point above 6m upto 10m from tapping point to out let via
switch
7
570
3990
code14 - Concelaed conduit System Supplying heavy gauge PVC Conduit pipe 19/20mm dia2mm thick confirming To IS 2509 with suitable size bends, metal/PVC junction boxes boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered PVC end enclosers, run with 18SWG GI fish wire wherever neccesary 19/20mm dia 2mm thick(p.1, Itm 1.1.1) Page-2 Vol-6
20
69
1380
code15 - Supplying and flush mounting teak wood box without front plank, made of not less than 12mm thick wood, after due grove cutting, finishing with necessary cement plastering complete (p.3, Itm 1.6.1) Page-2 Vol-6
2
120
240
code16 - Supplying and fixing regular M.C.B. distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB’s single phase/3phase/single door with powder coated painting made out of 14SWGM.S enclosure (page 55, I.no. 6.17.1)
1
777
777
code17 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burni g hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.1 LED light fitting 1 x 2' - 9/10 W (p.43, Itm 11.3.1) Page-2 Vol-6
10
551
5510
code18 - 12.26 Supplying of box fitting, made out of CRCA Sheet metal body with
locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube 1 x 4' Tube light fitting.(P-50,It-12.26.2 of PWD Electrical S.R. of 2023-24) Vol-6
20
461
9220
code19 - Wiring for lighting/ power circuit using one FRLS P.V.C.insulated 1100v.grade multistrand Copper with low conducror resistance single core wire in open or concealed system of wiring with specified IS 694 :1990 &confirming to the attached GTP of GROUP-A1.5 sq mm (p.6,I.2.5.2)
120
26
3120
code20 - Wiring for lighting/ power circuit using one FRLS P.V.C.insulated 1100v.grade multistrand Copper with low conducror resistance single core wire in open or concealed system of wiring with specified IS 694 :1990 &confirming to the attached GTP of GROUP-A2.5 sq mm (p.6,I.2.5.3)
240
40
9600
code21 - Supplying 6A flush type socket and 6amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box wiring using necessary capacity wires as required as per IS 1293 and IS 36543.1.1 6A 2 Way (Page No. 8, I.No.3.11)
12
128
1536
code22 - Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper
cable and a battery operated wireless remote unit 6.7.2 1.5 Ton capacity(Page No. 31, I.No.6.7.2) Vol-6
2
47683
95366
code23 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 3.6.4 Stepped Fan Regulator Two Module Fan Regulator
13
357
4641
code24 - Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system. 6.3.1 48" Sweep (1200 mm) Regular model (P-30,It-6.3.1 of PWD Electrical S.R. of 2023-24)
13
2984
38792
code25 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (page No.54, I.no 12.56) PWD Electrical S.R. of 2023-24)
1
3510
3510
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements