Karnataka State Road Transport Corporation Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 52,060Document Cost
Refer DocumentsTender Fee
₹ 530
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
KSRTC/2024-25/WT/WORK_INDENT92Tender No
KSRTC/2024-25/WT/WORK_INDENT92Tender Authority
Karnataka State Road Transport Corporation ViewPurchaser Address
-Website
http://https://ksrtc.in/oprs-web/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
C004 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) (SRP-2021-22/V-1/2.1.2/15)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates -(Issue rate 02)
18
5206
93708
C005 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates (SRP-2021-22/V-1/2.4.3/17) + (Appendix-1/2a P 115) -(Issue rate 02) & corri-03
25
8089
202230
C006 - Providing Thermo-Mechanically Treated bars of grade Fe-550D reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(SRP-2021-22/V-2/11.32/84) Issue rate-02
3250
92
299000
C007 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(SRP-2021-22/V-2/8.3.1/41)-(Issue rate 02)
230
299
68770
C008 - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SRP-2021-22/V-2/8.32/46)
230
112
25760
C009 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..(SRP-2021-22/V-2/81/11.16.2))
1025
109
111725
C010 - Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including primingcoat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(SRP-2021-22/V-2/11.34.B/85)Issue rate-02
1000
145
145000
C011 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg/m2: 160mm(weight of pipe -3.923 kg) (V-5 P 140/12-13.5)
80
599
47920
C012 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(V-5 P 187/18-9)
7
4977
34839
C013 - Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. .(V-5 P 210/20-3) V010C
7
1887
13209
C014 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg/m2: 110mm(weight of pipe -1.894 kg) (V-5 P 140/12-13.3)
20
366
7328.4
C015 - Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work).(V2 item no 13.33.4) (Crri-01) 32mm nominal OD pipes m
30
358
10740
C016 - Laying different Gradation of Metal in sludge tank including complete as per Direction of engineer incharge 40mm size aggregate (page A-38-7)
10
1250
12500
C017 - Laying different Gradation of Metal in sludge tank including complete as per Direction of engineer incharge 20mm size aggregate (page A-38-4)
10
1350
13500
C018 - Laying different Gradation of Metal in sludge tank including complete as per Direction of engineer incharge 06mm size aggregate (page A-38-01)
10
1380
13800
C019 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. (SRP-2021-22/V-2/14/6.8) -(Issue rate 02)
3.55
6690
23749.5
C020 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m..(SRP-2021-22/V-1/1.9/7)
120
204
24480
C021 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(SRP-2021-22/V-2/8..40/48))
130
90
11700
C022 - Supplying of Three phase 2HP Submersible Raw water Sewage /mud pumpsets 5M3/hr capacity & 7.5 mtr Head pump sets. CI. (NWKRTC Approved Rates)
2
15491
30982.14
C023 - Supplying of Three phase 2HP SubmersibleFilter Feed pump sets 5M3/hr capacity & 15 mtr Head pump sets.CI. (NWKRTC Approved Rates)
2
27444
54889.28
C024 - Supplying of Three phase 2HP Submersible Aerator pump sets 15M3/hr Air capacity .CI.
(NWKRTC Approved Rates)
2
32991
65982.14
C025 - Supplying, Installation and Commissioning of Dual Media Filter with multi port valve & Required media. (NWKRTC Approved Rates)
1
34392
34392.86
C026 - Supplying & fixing of DANGER BOARD made out of MS sheet metal with two coats of non corrossive enamel paint. (PWD ELE SR 2010-11. SRP 66/12)
2
66
133.92
C027 - Supplying & Installation of RUBBER MAT 1mt X 2mt-10mm thick. (PWD ELE SR2010-11/P 66/13)
1
986
986.61
C028 - Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets /Couplings /Tees /Bends /End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables.50mm OD 38mm. (PWD ELE SR 2014-15.SRP 63/7.20.2)
300
134
40446
C029 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland a nd box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG. (Ele. CSR 2021-22.SRP 15 of 47/5.42.2)
125000
-
47500
C030 - Supplying 100 amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete 100Amps 4x30x6mm Aluminium Strips. (Ele CSR 2021-22, SRP 15 of 47/5.40.1)
0.5
2214
1107
C031 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898, (6-32Amps TPN MCB. Ele CSR 2021-22,SRP 13 of 47/5.17.7)
8
1777
14216
C032 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 . 50-63Amps TPN MCB. (Ele CSR 2021-22,SRP 13 of 47, 5.17.9)
10
2399
23990
C033 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps D.P. (Elec CSR 2021-22,SRP 13 of 47, 5.17.4)
4
1103
4412
C034 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts,necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic release Micro processor release shall have Earth Fault as per IS-13947.( Icu = 100% Ics).In 4P MCCB,all poles should have protection for short circuit / over load, for Microprocessor MCCB'S Facility for segregating Priority and Non Priority loads must be available in the MCCB . MCCB shall be provided with double insulation ( Insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi pole breakers shall be designed to break all the poles simeltaneously and they shall have a single mechanism. 100 Amps 25kA 4 Pole. (Ele. CSR 2021-22,SRP 12 of 47, 5.14.7)
1
8265
8265
C035 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. (Ele CSR 2021-22, SRP 14 of 47, 5.33)
1
8370
8370
C036 - Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer.class 0.5 accurecy with Tape Wound. (Ele CSR 2021-22, SRP 14 of 47, 5.34)
3
505
1515
C037 - Supplying and running Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc., 8 SWG Copper Wire. (Ele SR 2019-20/P 43-44 / 6.18.6)
80
105
8400
C038 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.600x600x3mm Copper plate. (Ele SR 2019-20/P 40/6.3.10)
3
6900
20700
C039 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C 50Hz 12/24v D.C. (Ele CSR 2021-22, SRP 14 of 47/5.38)
3
464
1392
C040 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40x40x6mm. (Ele CSR 2021-22, SRP 15of 47, 5.41.1)
8
275
2200
C041 - 1.1 kv, XLPE or Heat resistant PVC insulated,PVC extruted Inner seath Armoured LTUG Cable as per IS-1554 (Part-1 ) or IS -7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 25 Sqmm ,3.5 core ,(12 GI Strips - 4 X 0.8mm) . (Ele CSR 2021-22. SRP 9 of 27/ 217, 32.07)
0.3
181452
54435.6
C042 - G I Pipe B - Class as per IS -1239. 40mm dia.
(Ele CSR 2021-22. SRP 16 of 27 / 409,49.04)
10
295
2950
C043 - Earth work excavation for Cable trench of 0.5m to 0.75mtr width & depth upto 1 mtr including trial pits, depositing on bank upto a lead of 50 mtr. Supplying & Diplaying necessary Danger boards and lighting using sight rails and sign boards at every 100mtr. wherever necessary as directed. In hard soil. (Elec CSR 2021-22, SRP 8 of 14/ 202-29.03)
80
389
31120
C044 - Refilling the cable trenches with slected available earth from tench exacavation including watering consolidation in layers of 15 cm thickness including depositing of the surplus earth with a lead of 200 mtrs. (Ele CSR 2021-22, SRP 8 of 14 , 206-29.07)
80
58
4640
C045 - Laying of cable in Existing Trench/GI Pipe /Stoneware /RCC Hume pipe using Wooden /Aluminium Rollers as directed by the departmental staff. LT Cable 2.5 sqmm to 25 sqmm. (Ele CSR 2021-22. SRP 9 of 14/ 230-31.05)
0.3
16159
4847.7
C046 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694 :1990 Confirming to latest amendments. 2.5Sqmm. (Elec CSR 2021-22, SRP 3 of 47 /2.3.3)
300
40
12000
C047 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694 Confirming to latest amendments. 4 Sqmm. (Elec CSR 2021-22, SRP 3 of 47 /2.3.4)
200
59
11800
C048 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694 Confirming to latest amendments. 16 Sqmm. (Elec CSR 2021-22, SRP 3 of 47 /2.3.7)
50
318
15900
C049 - Supplying heavy gauge PVC conduit pipe 25mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick. (Ele CSR 2021-22, SRP 1 of 47 / 1.1.2)
200
80
16000
C050 - Supplying PVC flexible conduit pipe 25 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on the either end of the pipe terminated completely. 25mm. (Ele CSR 2021-22, SRP 2of 47 / 1.9.2)
30
31
930
C051 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010. 3C x 4.0 Sqmm.(Ele CSR 2021-22, SRP 4 of 47 / 2.6.3)
200
167
33400
C052 - Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrossion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 3 phase motor/single phase motor upto 5HP. (Ele CSR 2021-22, SRP 10 of 47 / 5.1)
8
1490
11920
C053 - Labour charges for Errection, Electrification and commissioning of Pump sets including aligning and balancing of all items including supply and errection of two pair of supporting clamps, borewell caps, cable clips & water tight gland cable protectors, bolts,nuts valve and gauges ,tools and equipments etc involved in the job as per the specifications with Necessary testing as per specifications, with testing of as per the instructions of engineer in charge of work. (Civil CSR 2021-22/vOL.v/163/38/P360A)
6
6150
36900
C054 - Labour charges for the errection of Indoor type panel boardUNITS with all necessary materials and labour tools and equipments including cement concrete for foundation bed etc, complete as per specification with testing of as per instructions of engineer in charge of work. (Civil CSR 2021-22/Vol.V/163/39/P370A)
1
1250
1250
C055 - Digging of Pit for providing G I pipe type earthing. Hard soil. (Elec CSR 2021-22. SRP 1 of 14 ( Labour Rates).22-1.6.2)
6
2267
13602
C056 - Grounding materials - Pipe type grounding G I grounding Pipe B - class , 42mm dia, 2.5 mtr long , 3.2mm thick with bolts, nut G I strips and washer complete. (Ele CSR 2021-22, SRP 17 of 27 / 439-54.01)
6
770
4620
C057 - Good quality well burnt charcoal for grounding purposes packed in non returnable gunny bagg of 30 kg each.
(Elec CSR 2021-22. SRP 17 of 27 / 440 -54.02)
6
660
3960
C058 - Good Quality salt for grounding purposes packed in 50 kg gunny bag. (Elec CSR 2021-22. SRP 17 of 27 / 441 -54.03)
6
303
1818
C059 - ACTVATED SAND FILTERS :Providing and fixing of 0.8 m dia pressure sand filter comprising of 5 mm thick 0.8 m dia shell joined with 10 mm thick M S flanges and Air vent pipe with gate value graded filter media comprising of sand ,pebbles , grit etc complete as per direction of engineer in charge ---- including all lead and lifts as per the direction of engineer in charge of work
1
78000
78000
C060 - BELT SKIMMER : Providing and fixing of BELT SKIMMER with 5 LPH tray with complete arrangement for skimming out oil etc complete ---- including all lead and lifts as per the direction of engineer in charge of work
1
45000
45000
C061 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70 CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given of LED Flood light 100 Watts. (Ele CSR 21-22, Volume - VI, SRP 37 of 47 / 11.9.2)
11
8172
89892
C062 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. (Elec CSR 21-22, Volume - VI, SRP 45 of 47 / 13. 5)
11
189
2079
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%