GAIL India Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

GAIL India Limited - GAIL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Dec 2023
Closing Date2 Jan 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
¾”OD X 0.095” min Wall thk. SS Tube (Refer TS Section III - A)

2890

-

-

... More
½”OD X 0.083” min Wall thk. SS Tube (Refer TS Section III - A)

297

-

-

... More
SUPPLY OF SS TUBES as per Technical Specification

-

-

-

... More
¾”OD X 0.095” min Wall thk.,Material SS316SS Tube (Refer TS Section III - A)

288

-

-

... More
½”OD X 0.083” min Wall thk.,Material SS316 SS Tube (Refer TS Section III - A)

36

-

-

... More
Note: Quantities beyond mentioned quantities may be provided as free issue.

-

-

-

... More
Supply of SS Fittings,Valves

-

-

-

... More
Quick Connect Body & Stem

-

-

-

... More
End connection:½" Tube OD, for stem & ½”NPT (F) for body Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F

25

-

-

... More
Plug

-

-

-

... More
Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

25

-

-

... More
Size : ¾" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

51

-

-

... More
Caps

-

-

-

... More
Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

25

-

-

... More
Size : ¾" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

127

-

-

... More
Union

-

-

-

... More
Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

595

-

-

... More
Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

51

-

-

... More
Reducing Union

-

-

-

... More
Tube OD 3/4" x Tube OD 1/2", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

119

-

-

... More
Equal Tee

-

-

-

... More
Size:½” OD x ½” OD x ½” OD, Material:SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

8

-

-

... More
Size:¾" OD x ¾" OD x ¾" OD, Material : SS316 ( Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

76

-

-

... More
Reducing Union Tee

-

-

-

... More
¾" OD x ½" OD x ¾" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

8

-

-

... More
Tube End Connection

-

-

-

... More
½” Tube End & ¾” OD with Ferrule Fitting, SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

102

-

-

... More
Nut

-

-

-

... More
¾ " OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

51

-

-

... More
½" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)

25

-

-

... More
Front Ferrule

-

-

-

... More
3/4" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

51

-

-

... More
½" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

25

-

-

... More
Back Ferrule

-

-

-

... More
3/4" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

51

-

-

... More
½" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

25

-

-

... More
Male Connector

-

-

-

... More
Size ¼” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

8

-

-

... More
Size 1/2” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

25

-

-

... More
Cross

-

-

-

... More
3/4" OD X 3/4” X 3/4" OD X3/4" OD Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)

8

-

-

... More
SS Ball Valves, conforming to MECON’s Technical Specification No. MEC/TS/05/62/048 for SS Ball Valves of following sizes, specifications as indicated below :

-

-

-

... More
2-Way Trunnion Full Bore Ball Valve ¾"

8

-

-

... More
2-Way Floating Full Bore Ball Valve ¾"

382

-

-

... More
2-Way Trunnion Full Bore Ball Valve ½"

8

-

-

... More
2-Way Floating Full Bore Ball Valve ½"

119

-

-

... More
3-Way Trunnion Mounted, Reducer Bore Ball Valve ½" OD end Connection and ¼” NPT (F) bottom end connection

8

-

-

... More
Conductive Core Thermoplastic Hose

-

-

-

... More
3/8” ID Conductive Core Thermoplastic Hose for CNG Service with break away coupling

8

-

-

... More
Supply of SS 304 Tubes along with isolation valves, reducers & fittings etc.as per Technical Specification, Typical schematic drg. for Ins. air line of CNG station and scope of work including handling, storage,lifting, transportation upto CNG stations. (Note:Total no.of ferrule fittings may be considered as one jointing ferrule at every 5.0 m)

-

-

-

... More
½”OD X 0.083” min Wall thk. SS Tube (Refer TS Section III - A)

42

-

-

... More
Laying, testing and commissioning of SS 304 Tubes along with isolation valves, reducers & fittings etc.as per Technical Specification, Typical schematic drg. for Ins. air line of CNG station and scope of work including handling, storage,lifting, transportation upto CNG stations. (Note:Total no.of ferrule fittings may be considered as one jointing ferrule at every 5.0 m)

-

-

-

... More
½”OD X 0.083” min Wall thk. SS Tube (Refer TS Section III - A)

42

-

-

... More
SECTION-B : ERECTION OF MECH. EQUIPMENT

-

-

-

... More
Handling (including lifting and transportation from Client's store within city to CNG stations) and erecting in position, the following equipment either on the foundation at Ground level or on roof at 3.5 m above ground level. Contractor's scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. :

-

-

-

... More
Cascade 4500/3000/2200 L water capacity. Erection at + 4.0 M level (Refer TS Section III - B)

25

-

-

... More
Cascade 4500/3000/2200 L water capacity, Erection at + Ground level (Refer TS Section III - B)

8

-

-

... More
Dispenser Erection at + Ground Level

38

-

-

... More
Note: The quantities given above against individual items are indicative and shall not be considered to be binding. The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge. The unit rate shall be operated to work out the final payment due to Contractor.

-

-

-

... More
SECTION-C : SUPPLY, ERECTION & COMMISSIONING OF MISCELLANEOUS ITEM

-

-

-

... More
Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC

-

-

-

... More
Air compressor pump (Refer TS Section III - C) (Tyre Inflator)

1

-

-

... More
Water cooler (Refer TS Section III - C)

1

-

-

... More
Fire fighting Equipments (Refer TS Section III - C)

-

-

-

... More
DCP -9 Kg

89

-

-

... More
DCP -75 Kg

25

-

-

... More
CO2 – 4.5 Kg

25

-

-

... More
Sand Bucket (4 Nos. on each strand)

25

-

-

... More
STRUCTURAL WORKS

-

-

-

... More
Pipe Supports & Other Structures

-

-

-

... More
Supply, fabrication and erection of all types of pipe supports like clamps, saddle, guide stops, cradles, turn buckles, anchors, T-posts; stockade/ trestle and pipe bridge for overhead piping; frames for canopy, approach ladders and platforms, crossover, cable tray supports, etc. including painting suitable for highly corrosive area as per specification labour and supervision & complete work as per drawings, specifications and instruction of Engineer-in-charge. (Bolts, nuts, washers, U-clamps etc. for supporting shall be supplied by the Contractor within the rates quoted. These items will not be measured and paid seperately). The work is to be completed in all respect as per scope of work and specification.

6

-

-

... More
Notes: 1)The quantities indicated above are tentative and may vary as per the site requirements. Final payment will be made based on executed quantities certified by the Owner/Owner's representative. 2)The quoted rates shall be inclusive of the cost of MS bolts (permanent and service), washers, electrodes, putty, gases, cost of straightening the raw materials, cutting of flats from plates and providing splices, paints, tools, plants etc., as required to complete the work. 3)All handling and transport charges of raw materials and fabricated structures including double handling, as required, for completion of work in accrodance with time schedule, are deemed be included in the quoted rates.

-

-

-

... More
PRESSURE GAUGES

-

-

-

... More
Supply, installation and calibration of pressure Gauges and their accessories inclusive of supply of necessary piping materials/tubings alongwith all necessary valves & fittings, fabrication and installation of impulse lines/manifolds as per D. S. No. MEC/23H7/05/E5/I/001/DS-PG.

25

-

-

... More
TEMPERATURE GAUGES

-

-

-

... More
Supply, installation and calibration of Temperature Gauges and their accessories inclusive of supply of necessary piping materials/tubings alongwith all necessary valves & fittings, fabrication and installation of impulse lines/manifolds as per D. S. No. MEC/23H7/05/E5/I/001/DS-PG.

25

-

-

... More
ELECTRICAL WORKS (SUPPLY)

-

-

-

... More
SUPPLY

-

-

-

... More
Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) :

-

-

-

... More
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/Q7NT/05/E9/E/1081A & as per standard Specification. Single incomer of 125 Amp (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) . Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor. Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel. Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE) for UPS and Static Bypass. Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCB without Timer

15

-

-

... More
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/Q7NT/05/E9/E/1081B & as per standard Specification. Single incomer of 100 Amp (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) . Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Gas Driven Compressor. Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE) for UPS and Static Bypass. Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCB without Timer

10

-

-

... More
Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification

15

-

-

... More
Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 150A, 415V, 4 Pole AC-23 duty and suitable for termination of 3.5 x 120/95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals with RYB Indication, Voltmeter & Ammeter etc.

15

-

-

... More
Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole AC-23 duty and suitable for termination of 3.5 x 120/95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals with RYB Indication, Voltmeter & Ammeter etc.

10

-

-

... More
Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.

-

-

-

... More
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover

125

-

-

... More
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover

25

-

-

... More
GI Strip (50X6) mm

2500

-

-

... More
GI Strip (25X3) mm

5000

-

-

... More
Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.

1

-

-

... More
Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.

25

-

-

... More
Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.

-

-

-

... More
3.5x 120 mm2 A2XFY

10

-

-

... More
3.5x 95 mm2 A2XFY

10

-

-

... More
3.5x 50 mm2 A2XFY

5000

-

-

... More
4x 25 mm2 A2XFY

500

-

-

... More
4x10 mm2 2XWY

500

-

-

... More
4x 6 mm2 2XWY

1250

-

-

... More
4x 2.5 mm2 2XWY

20000

-

-

... More
Supply including packing and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.

-

-

-

... More
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear Model no. FLPW-1095 of Baliga make or equivalent)

150

-

-

... More
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.

150

-

-

... More
UPS SYSTEM Design, supply, packing, forwarding, delivery by equipment supplier at site including commissioning spares as required of UPS systems as per specification, datasheet, block diagram of the following rating :

-

-

-

... More
3KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass supply, Battery Bank, ACDB (Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB) and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel.

25

-

-

... More
Supply,Transportation at site of following sizes of HDPE Pipe in required length fixed on steel, concrete or similar structure, laid in trenches, digging, construct conduit ductbank and buried in concrete including cutting, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., civil works and its materials, including all labour and materials complete as per approved drawings and directions of Engineer-In-Charge.

-

-

-

... More
50 mm NB

8000

-

-

... More
100 mm NB

4000

-

-

... More
Supply of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge

-

-

-

... More
Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.

-

-

-

... More
150mm wide

250

-

-

... More
300mm wide

250

-

-

... More
Erection Material

-

-

-

... More
Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.

-

-

-

... More
For RO/DBS

25

-

-

... More
Supply of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.

-

-

-

... More
Shock hazard charts complete with frame and glass

25

-

-

... More
First Aid Boxes

25

-

-

... More
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate

50

-

-

... More
Caution boards (Danger, High Volatage) including supply of necessary clamps, bolts and other hardware.

25

-

-

... More
Single Line Diagram complete in glass frame.

25

-

-

... More
Supply of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.

125

-

-

... More
Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.

-

-

-

... More
For RO/DBS

25

-

-

... More
Supply of required material for construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.

-

-

-

... More
500X500(of inside clearance)X 600(Depth)

125

-

-

... More
750X750(of inside clearance)X800(Depth)

125

-

-

... More
1000X1000(of inside clearance)X1000(Depth)

50

-

-

... More
ELECTRICAL WORKS (Erection)

-

-

-

... More
ERECTION,TESTING AND COMMISSIONING

-

-

-

... More
Erection Testing and Commissioning of power distribution board (PDB):

-

-

-

... More
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/Q7NT/05/E9/E/1081A & as per standard Specification. Single In-comer of 125 Amp (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) . Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor. Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel. Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE) for UPS and Static Bypass. Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCB without Timer

15

-

-

... More
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/Q7NT/05/E9/E/1081B & as per standard Specification. Single incomer of 100 Amp (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) . Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Gas Driven Compressor. Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE) for UPS and Static Bypass. Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCB without Timer

10

-

-

... More
Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCB) as specified in tender specification

15

-

-

... More
Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 150A, 415V, 4 Pole AC-23 duty and suitable for termination of 3.5 x 120/95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals with RYB Indication, Voltmeter & Ammeter.

15

-

-

... More
Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole AC-23 duty and suitable for termination of 3.5 x 120/95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals with RYB Indication, Voltmeter & Ammeter etc.

10

-

-

... More
Erection Testing and Commissioning of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.

-

-

-

... More
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover

125

-

-

... More
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover

25

-

-

... More
GI Strip (50X6) mm

2500

-

-

... More
GI Strip (25X3) mm

5000

-

-

... More
Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.

1

-

-

... More
Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.

25

-

-

... More
Laying, Termination, Glanding, Testing and Commissioning of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.

-

-

-

... More
3.5x 120 mm2 A2XFY

10

-

-

... More
3.5x 95 mm2 A2XFY

10

-

-

... More
3.5x 50 mm2 A2XFY

5000

-

-

... More
4x 25 mm2 A2XFY

500

-

-

... More
4x10 mm2 2XWY

500

-

-

... More
4x 6 mm2 2XWY

1250

-

-

... More
4x 2.5 mm2 2XWY

20000

-

-

... More
Erection Testing and Commissioning of of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.

-

-

-

... More
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear Model no. FLPW-1095 of Baliga make or equivalent)

150

-

-

... More
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.

150

-

-

... More
UPS SYSTEM Erection Testing and Commissioning of including supervision of testing and commissioning by equipment supplier at site including commissioning spares as required of UPS systems as per specification, block diagram and following rating:

-

-

-

... More
3KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass supply, Battery Bank, ACDB (Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB) and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel.

25

-

-

... More
Erection of following sizes of HDPE Pipe in required length fixed on steel, concrete or similar structure, laid in trenches, digging, construct conduit ductbank and buried in concrete including cutting, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., civil works and its materials, including all labour and materials complete as per approved drawings and directions of Engineer-In-Charge.

-

-

-

... More
50 mm NB

8000

-

-

... More
100 mm NB

4000

-

-

... More
Erection of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including Erection of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge

-

-

-

... More
Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.

-

-

-

... More
150mm wide

250

-

-

... More
300mm wide

250

-

-

... More
Erection Material

-

-

-

... More
Erection, Fixing and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, Erection of necessary anchor bolts and grouting etc Erection of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including Erection of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.

-

-

-

... More
For RO/DBS

25

-

-

... More
Erection Testing and Commissioning of the following including the Erection of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.

-

-

-

... More
Shock hazard charts complete with frame and glass

25

-

-

... More
First Aid Boxes

25

-

-

... More
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate

50

-

-

... More
Caution boards (Danger, High Volatage) including Erection of necessary clamps, bolts and other hardware.

25

-

-

... More
Single Line Diagram complete in glass frame.

25

-

-

... More
Laying and Pasting of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.

125

-

-

... More
Erection Fixing and Commissioning of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.

-

-

-

... More
For RO/DBS

25

-

-

... More
Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.

-

-

-

... More
500X500(of inside clearance)X 600(Depth)

125

-

-

... More
750X750(of inside clearance)X800(Depth)

125

-

-

... More
1000X1000(of inside clearance)X1000(Depth)

50

-

-

... More
All works relating to statutory approvals of the installation from competent authority like Electrical Inspectorate, CEA, DGMS, SEB etc. including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liasion with the authorities to obtain all necessary clearances for charging of installation as per relevant national standards. However the official fees towards the approvals shall be reimbursed by the client.

25

-

-

... More
Total Amount excluding GST

-

-

-

... More
GST (CGST & SGST / UTGST or IGST) @ 18% of Net Total Amount mentioned at Sl. No. 184 above. (Enter rate of applicable GST)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.