Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Eastern Railway - ER Tender

Goods
Ireps
Opening Date30 Jul 2024
Closing Date23 Aug 2024
Tender Amount₹ 6,50,79,785.67 
Notes
Download

Costs

Summary

Provision Of New 6quad Cable In Rph-dumka & Repl. Of Defective 6q In Kwae Section & Nht-az Section& Prov Of Emergency Comm System In Hwh Divi.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in hard soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work 5 shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4"" of 1:2:4 concreting should be done. Note:-(b-1) payment will be made as per actual work done on pro-rata basis, if required depth is not available at site.(b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. "

6750

607

4097275.65

... More
Supply, transportation at site and installation of RCC cable route marker engraved and painted on both side along the route at every 50 meter and at route diversion. The cable route marker is to be fabricated as per RDSO drawing No RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. The fixing work is to be done as per extent practice of E.Rly and as per Railway site supervisor Inspection : Consignee

1000

417

417000.2

... More
Laying of Signalling/Telecom /Power / Quad/ OFC cable of different size through DWC/GI/HDPE 7 pipe in the Trench with protective work as per instruction of site engineer as per railway practice, it includes fixing of cable on wall with suitable clamps(the clamps and screws should be made of Stainless steel). All the fixing materials including Coller, bend, junction etc. shall be supplied by the contractor. (Cable, DWC/GI/HDPE pipe will be supplied by the Railway and shall be transported from store to site by the contractor).

50000

237440

237440

... More
REPAIRING OF PUCCA ROAD TO ORIGINAL STATE IN L.C.GATE AREA AFTER CABLE LAYING

500

242

121492

... More
"Cutting of concrete platform to a depth of 200 mm and width of 100 mm to lay DATA/POWER/Telecom cable through DWC Pipe of 63/50 mm dia. Contractor has to redress the cutting place into its original position without destroying the beauty after cable laying. This includes supply of DWC pipe of 63/50 mm dia. of IS: 14930 Pt-II mark. (Cable will be supplied by the Railway)"

500

167

83731.2

... More
Supply of Thermoshrink Jointing kits for underground 0.9MM dia conductor 4/6 Quad cable as per RDSO spec. No IRS :TC/77-2012, Rev.3 with Amd no 1 & 2 or latest. Inspection by authorised representative of Sr. DSTE/HWH. Note: material to be made available just before execution so that the life does not expire before use. INSPECTION : CONSIGNEE.

70

2073

145172.5

... More
Jointing of 4/6 Quad Cable

70

907

63517.33

... More
"Supply of DWC pipe along with Socket/Coupler Conforming to IS:14930, Part-II (Earlier BSEN- 12 50086-1 BSEN-50086-2-4) for protection of Underground/ Communication / Signaling / OFC cable. The Pipe to be of 63MM outer dia 50MM inner dia. The pipe to be of ISI Marked with non-flame propagating, anti rodent properties and have IP 67 protection on coupling arrangement to be supplied at 6mtr length. INSPECTION CONSIGNEE."

500

376

188406.4

... More
Supply and fixing of G.I. pipe with iron clamps on bridge / culverts / track crossing etc. for cable 14 laying jointing with threaded collers of 80 mm normal bore Spec. No. IS:1239 medium grade. Inspection by authorised representative of Sr. DSTE/HWH.

1000

958

958720

... More
Installation for G.I. pipe & collers (Spec. No. IS:1239 medium grade), Excavation, Trenching upto 1M depth, Earth Work and Re-instatement of Track while Track Crossing after laying of GI pipe(1 Mtr Depth, 300 mm Width).. ( This includes installation of GI pipe dismantled from Bridge) ( Cable will be supplied by the Railway).

1000

62

62720

... More
Supply of 4W way station DTMF equipment as per RDSO spec. no IRS-TC 60 93 or latest ( with 4 wire telephone as per spec. No IRS-TC 38 97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone. Inspection by Consignee

12

6710

80520

... More
Installation of 4W way station DTMF equipment as per RDSO spec. no IRS-TC 60 93 or latest ( with 4 wire telephone as per spec. No IRS-TC 38 97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone.

12

1257

15084

... More
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. Inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]

10

23886

238868.11

... More
a) Supply of basic material to construct Maintenance Free Earth as per RDSO/SPN/ 197/2014, Version 1.0 or latest consisting of following items:(Inspection-Consignee).(i) Copper bonded steel electrode 3m long, 17.0 mm dia with copper bonding thickness of min 250 micron and UL listed & marked - 1no.(ii) Earth Enhanceme compound of RDSO approved brand supplied in sealed bags of min 10 kgs - 3 nos. (iii) Copper Strip 21 of 150 x 25 x 6mm to terminate Earth Rod -1 no.(iv) Copper Strip of 300 x 25 x 6mm (MEEB) - 1 no.(v) Copper Strip of 150 x 25 x 6mm (SEEB) - 1 no.b) Supply of 35sq mm Multi-strand single core PVC insulated copper cable as per IS:694 or latest for connecting Main Earth Electrode to MEEB in the equipment room in duplicate as per requirement at site (Inspection-Consignee).c) Supply of 16sq mm Multi-strand single core PVC insulated copper cable as per IS:694 or latest for connecting SEEB to MEEB and SPDs to MEEB as per requirement at site. (Inspection-Consignee).d) Supply of 10sq mm Multi-strand single core PVC insulated copper cable as per IS:694 or latest for connecting various equipments to SEEB as per requirement at site.(Inspection-Consignee).

10

14376

143768.13

... More
a) Installation of Unit Maintenance Free Earth as supplied in above item. which includes the following -(i) Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia to the depth of approx. 2.8meter. (ii) Insertion of 3m electrode and penetrating it atleast 0.2m by pushing gently with sludge hammer where the natural soil is assumed.(iii) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling.(iv) Carrying out exothermic welding connection on single earth electrode to a copper tape of 150x25x6mm.(v) Carrying out exothermic weld connection on the copper tape of 150x25x6mm on Earth Electrode for connecting two 35 Sq mm copper cables for redundancy.(vi) The exothermic welding material for bonding the 22 earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders.(vii) 300x300x300 mm (inside dimension) concrete Earth Pit with a concrete lid, approx 50mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and average resistance value shall be written.b) (i) Digging a trench to a depth of atleast 0.5m and run the two 35sq mm copper conductor from Earth pit to MEEB.(ii) Routing and termination of two 35sq mm copper conductors in trench from earth pit to 300X25X6mm MEEB, which is to be fixed inside the equipment room with two insulation studs.c) Routing and connecting of all SPDs in the equipment room to MEEB with 16sq.mm. copper cable using copper lugs with stainless nuts and bolts.d) Routing and connecting of all the equipment in the equipment/relay room to MEEB/SEEB with 10sq.mm.copper cable using copper lugs with stainless steel nut, bolts and fixures. This work includes laying and routing of copper cable in PVC pipes/conduits and fixing them on walls.

10

6244

62444.7

... More
"Supply of 6 QUAD UNDERGROUND JELLY FILLED QUAD CABLE FOR SIGNALLING AND TELECOM INSTALLATION SIZE:6QUAD X 0.9 MM DIA AS PER RDSO SPECIFICATION NO-IRS:TC- 30/2005(VER.1) WITH AMENDMENT NO.5 OR LATEST AMENDMENT INSPECTION : RDSO."

33

284974

9404165.76

... More
"Fixing of Outdoor cable termination box or termination of outdoor PIJF/QD cable installation portion including fixing of 20 Pair CT box on wall /inside location box termination of cable in CT box & sealing cable termination box Spec. No. IRS-TC/18-75 or latest. INSPECTION : CONSIGNEE. Execution ( CT box will be supplied by Railway )"

10

1242

12425.4

... More
"Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of 4 route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4"" of 1:2:4 concreting should be done. (b-1)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Inspection: Consignee. "

17820

245

4365960.59

... More
Supply, transportation at site and installation of RCC cable route marker engraved and painted on both side along the route at every 50 meter and at route diversion. The cable route marker is to be fabricated as per RDSO drawing No RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. The fixing work is to be done as per extent practice of E.Rly and as per Railway site supervisor

660

417

275220.13

... More
Laying of Signalling/Telecom /Power / Quad/ OFC cable of different size through DWC/GI/HDPE 6 pipe in the Trench with protective work as per instruction of site engineer as per railway practice, it includes fixing of cable on wall with suitable clamps(the clamps and screws should be made of Stainless steel). All the fixing materials including Coller, bend, junction etc. shall be supplied by the contractor. (Cable, DWC/GI/HDPE pipe will be supplied by the Railway and shall be transported from store to site by the contractor).

33000

156710

156710.4

... More
REPAIRING OF PUCCA ROAD TO ORIGINAL STATE IN L.C.GATE AREA AFTER CABLE LAYING

500

242

121492

... More
"Cutting of concrete platform to a depth of 200 mm and width of 100 mm to lay DATA/POWER/Telecom cable through DWC Pipe of 63/50 mm dia. Contractor has to redress the cutting place into its original position without destroying the beauty after cable laying. This includes supply of DWC pipe of 63/50 mm dia. of IS: 14930 Pt-II mark. (Cable will be supplied by the Railway)"

500

167

83731.2

... More
Jointing of 4/6 Quad Cable

70

907

63517.33

... More
"Supply of DWC pipe along with Socket/Coupler Conforming to IS:14930, Part-II (Earlier BSEN- 11 50086-1 BSEN-50086-2-4) for protection of Underground/ Communication / Signaling / OFC cable. The Pipe to be of 63MM outer dia 50MM inner dia. The pipe to be of ISI Marked with non-flame propagating, anti rodent properties and have IP 67 protection on coupling arrangement to be supplied at 6mtr length. INSPECTION CONSIGNEE."

500

376

188406.4

... More
Supply and fixing of G.I. pipe with iron clamps on bridge / culverts / track crossing etc. for cable laying jointing with threaded collers of 80 mm normal bore Spec. No. IS:1239 medium grade. Inspection by authorised representative of Sr. DSTE/HWH.

500

958

479360

... More
Installation for G.I. pipe & collers (Spec. No. IS:1239 medium grade), Excavation, Trenching upto 1M depth, Earth Work and Re-instatement of Track while Track Crossing after laying of GI pipe(1 Mtr Depth, 300 mm Width).. ( This includes installation of GI pipe dismantled from Bridge) ( Cable will be supplied by the Railway).

500

62

31360

... More
Installation of magneto / control telephone, annunciator with all accessories and dry cells (2 nos.) For each phone with wooden battery box. This includes supply of magneto telephones with all accessories including supply of 2 nos. Dry cell for each telephone with wooden battery box. (i) SPEC.FOR magneto telephone IRS-TC- 79/2000.AMD-1 OR LATEST.EXECUTION

10

126

1264.3

... More
Supply of 4W way station DTMF equipment as per RDSO spec. no IRS-TC@47<47@93 or latest ( with 4 wire telephone as per spec. No IRS-TC@45&47@97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone. Inspection by Consignee

10

6710

67100

... More
Installation of 4W way station DTMF equipment as per RDSO spec. no IRS-TC@47<47@93 or latest ( with 4 wire telephone as per spec. No IRS-TC@45&47@97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone.

10

1257

12570

... More
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. Inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]

10

23886

238868.11

... More
Supply of earth electrode mild steel galvanized, light class, IS:1239(PART-I)-1979.earth electrode 20 pipe should be with 3 mm thick, 50 mm dia and perforated(staggered),5 mm dia holes, 2 nos per 305 mm length with clamp of MS FLAT (galvanized) of size 35 mm x 6 mm (SPEC.NO.226 STD). Earth pipe should include CI threaded cap. Materials to be procured and designed as per CSTE/ER'S DRG.NO.S&T-1/2007. Inspection: - BY RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]

30

1496

44880.12

... More
Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE/ER'S DRG. NO. S&T 1/2007 for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus 22 cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note: -all materials required to be arranged by the contractor except 2 core cable will be supplied by the railway.

30

1161

34830

... More
"Disconnection & Reconnection of All Telecom Equipments like Cables/Joints/terminationand other telecom works. This includes Supply of Labours(Helper/Assistant) of 5 Nos per Man Day to assist Telecoml Supervisor / Officer during Field Work & Other S&T work. "

30

2973

89208

... More
"Supply of 6 QUAD UNDERGROUND JELLY FILLED QUAD CABLE FOR SIGNALLING AND TELECOM INSTALLATION SIZE:6QUAD X 0.9 MM DIA AS PER RDSO SPECIFICATION NO-IRS:TC- 30/2005(VER.1) WITH AMENDMENT NO.5 OR LATEST AMENDMENT INSPECTION : RDSO."

47

284974

13393811.84

... More
"Fixing of Outdoor cable termination box or termination of outdoor PIJF/QD cable installation portion including fixing of 20 Pair CT box on wall /inside location box termination of cable in CT box & sealing cable termination box Spec. No. IRS-TC/18-75 or latest. INSPECTION : CONSIGNEE. Execution ( CT box will be supplied by Railway )"

20

1242

24850.8

... More
"Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of 4 route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4"" of 1:2:4 concreting should be done. (b-1)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Inspection: Consignee. "

24300

245

5953582.62

... More
Laying of Signalling/Telecom /Power / Quad/ OFC cable of different size through DWC/GI/HDPE 6 pipe in the Trench with protective work as per instruction of site engineer as per railway practice, it includes fixing of cable on wall with suitable clamps(the clamps and screws should be made of Stainless steel). All the fixing materials including Coller, bend, junction etc. shall be supplied by the contractor. (Cable, DWC/GI/HDPE pipe will be supplied by the Railway and shall be transported from store to site by the contractor).

45000

213696

213696

... More
REPAIRING OF PUCCA ROAD TO ORIGINAL STATE IN L.C.GATE AREA AFTER CABLE LAYING

500

242

121492

... More
"Cutting of concrete platform to a depth of 200 mm and width of 100 mm to lay DATA/POWER/Telecom cable through DWC Pipe of 63/50 mm dia. Contractor has to redress the cutting place into its original position without destroying the beauty after cable laying. This includes supply of DWC pipe of 63/50 mm dia. of IS: 14930 Pt-II mark. (Cable will be supplied by the Railway)"

500

167

83731.2

... More
Supply of Thermoshrink Jointing kits for underground 0.9MM dia conductor 4/6 Quad cable as per RDSO spec. No IRS :TC/77-2012, Rev.3 with Amd no 1 & 2 or latest. Inspection by authorised representative of Sr. DSTE/HWH. Note: material to be made available just before execution so that the life does not expire before use. INSPECTION : CONSIGNEE.

55

2073

114064.1

... More
Jointing of 4/6 Quad Cable

55

907

49906.47

... More
"Supply of DWC pipe along with Socket/Coupler Conforming to IS:14930, Part-II (Earlier BSEN- 11 50086-1 BSEN-50086-2-4) for protection of Underground/ Communication / Signaling / OFC cable. The Pipe to be of 63MM outer dia 50MM inner dia. The pipe to be of ISI Marked with non-flame propagating, anti rodent properties and have IP 67 protection on coupling arrangement to be supplied at 6mtr length. INSPECTION CONSIGNEE."

500

376

188406.4

... More
Supply and fixing of G.I. pipe with iron clamps on bridge / culverts / track crossing etc. for cable laying jointing with threaded collers of 80 mm normal bore Spec. No. IS:1239 medium grade. Inspection by authorised representative of Sr. DSTE/HWH.

1000

958

958720

... More
Installation for G.I. pipe & collers (Spec. No. IS:1239 medium grade), Excavation, Trenching upto 1M depth, Earth Work and Re-instatement of Track while Track Crossing after laying of GI pipe(1 Mtr Depth, 300 mm Width).. ( This includes installation of GI pipe dismantled from Bridge) ( Cable will be supplied by the Railway).

1000

62

62720

... More
Supply of 4W way station DTMF equipment as per RDSO spec. no IRS-TC@47<47@93 or latest ( with 4 wire telephone as per spec. No IRS-TC@45&47@97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone. Inspection by Consignee

22

6710

147620

... More
Installation of 4W way station DTMF equipment as per RDSO spec. no IRS-TC@47<47@93 or 16 latest ( with 4 wire telephone as per spec. No IRS-TC@45&47@97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone.

21

1257

26397

... More
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. Inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]

7

23886

167207.68

... More
a) Supply of basic material to construct Maintenance Free Earth as per RDSO/SPN/ 197/2014, Version 1.0 or latest consisting of following items:(Inspection-Consignee).(i) Copper bonded steel electrode 3m long, 17.0 mm dia with copper bonding thickness of min 250 micron and UL listed & marked - 1no.(ii) Earth Enhanceme compound of RDSO approved brand supplied in sealed bags of min 10 kgs - 3 nos. (iii) Copper Strip 20 of 150 x 25 x 6mm to terminate Earth Rod -1 no.(iv) Copper Strip of 300 x 25 x 6mm (MEEB) - 1 no.(v) Copper Strip of 150 x 25 x 6mm (SEEB) - 1 no.b) Supply of 35sq mm Multi-strand single core PVC insulated copper cable as per IS:694 or latest for connecting Main Earth Electrode to MEEB in the equipment room in duplicate as per requirement at site (Inspection-Consignee).c) Supply of 16sq mm Multi-strand single core PVC insulated copper cable as per IS:694 or latest for connecting SEEB to MEEB and SPDs to MEEB as per requirement at site. (Inspection-Consignee).d) Supply of 10sq mm Multi-strand single core PVC insulated copper cable as per IS:694 or latest for connecting various equipments to SEEB as per requirement at site.(Inspection-Consignee).

15

14376

215652.19

... More
a) Installation of Unit Maintenance Free Earth as supplied in above item. which includes the following -(i) Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia to the depth of approx. 2.8meter. (ii) Insertion of 3m electrode and penetrating it atleast 0.2m by pushing gently with sludge hammer where the natural soil is assumed.(iii) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling.(iv) Carrying out exothermic welding connection on single earth electrode to a copper tape of 150x25x6mm.(v) Carrying out exothermic weld connection on the copper tape of 150x25x6mm on Earth Electrode for connecting two 35 Sq mm copper cables for redundancy.(vi) The exothermic welding material for bonding the 21 earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders.(vii) 300x300x300 mm (inside dimension) concrete Earth Pit with a concrete lid, approx 50mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and average resistance value shall be written.b) (i) Digging a trench to a depth of atleast 0.5m and run the two 35sq mm copper conductor from Earth pit to MEEB.(ii) Routing and termination of two 35sq mm copper conductors in trench from earth pit to 300X25X6mm MEEB, which is to be fixed inside the equipment room with two insulation studs.c) Routing and connecting of all SPDs in the equipment room to MEEB with 16sq.mm. copper cable using copper lugs with stainless nuts and bolts.d) Routing and connecting of all the equipment in the equipment/relay room to MEEB/SEEB with 10sq.mm.copper cable using copper lugs with stainless steel nut, bolts and fixures. This work includes laying and routing of copper cable in PVC pipes/conduits and fixing them on walls.

15

6244

93667.06

... More
"Disconnection & Reconnection of All Telecom Equipments like Cables/Joints/terminationand other telecom works. This includes Supply of Labours(Helper/Assistant) of 5 Nos per Man Day to assist Telecoml Supervisor / Officer during Field Work & Other S&T work. "

90

2973

267624

... More
Supply of Failure Analysis System (FAS) with Fault Analysis Software (Datalogger Analyser) consisting of a PC (Make- Dell /HP or Equivalent) as per Technical Specifications. The specification of FAS should be got approved from the Engineer in charge before supply. Note: The minimum specification should be as given 23 core i7 or higher version processor (speed 3.2 GHZ, 4 MB cache memory), 8 GB RAM,2TB HDD or Higher, Two front and four rear USB port,1 Serial & 1 Parallel Port,1VGA Port,21" LED Colour Monitor (HP/DELL or equivalent) or Bigger Size, Sound Card with Speaker,1000 MBPS Network Card, Keyboard, Optical Mouse,10/100 T Lan Card, Combo Drive, Microsoft Windows 10 Licensed OS with Licensed (Antivirus, MS Office etc.),UPS 750 VA with 30 Minutes minimum backup(APC/ Microtek or Equivalent) , Laserjet Printer(H P Pro 1108 or superior). Inspection: Consignee

3

116554

349662.01

... More
"LOADING, UN-LOADING & TRANSPORTATION OF MATERIALS INCLUDING CABLES, LOCATION BOXES AND MISCELLANEOUS ITEMS REQUIRED FROM VARIOUS PLACES IN 9MT TRUCK TO THE RAILWAY STORES AS PER SITE ENGINEER. (ii) Loading and Unloading "

8

1883

15063.97



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.