Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Eprocure
Opening Date20 Aug 2020
Closing Date12 Sep 2020
Tender Amount₹ 75,00,000
Costs
EMD
₹ 1,50,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_PDD_98937_2Bid Award Id
ViewTender No
STDS/07 of 2020-21Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SITC of 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
3
-
-
SITC of 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO,Polymer) gap less
3
-
-
SITC of 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5Amps, DLMS Compliant with RS-485 port
1
-
-
SITC of 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m
3
-
-
SITC of GI pipe nominal bore 200,5.9mm thick
1.87
-
-
SITC of Galvanized Steel Structures
1.04
-
-
SITC of Galvanized Nuts & Bolts
0.15
-
-
SITC of 12 Core 2.5 mm² Control cable copper Armored , 1.1 KV Grade, ISI, FRLS.
60
-
-
SITC of 6 Core 2.5 mm² Control cable copper Armored , 1.1 KV Grade, ISI, FRLS.
300
-
-
SITC of 2 Core 2.5 mm² Control cable copper Armored , 1.1 KV Grade, ISI, FRLS.
60
-
-
SITC of Lugs, Ferrules etc.
1
-
-
SITC of ACSR Conductor Panther
100
-
-
SITC of T Clamps
3
-
-
Commissioning of 33/11 KVPOWER TRANSFORMER
-
-
-
Installation ,testing & commissioning 33/11KV, ONAN, Copper wound, Out‐door Type, conventional 6.3 MVA Power Transformer, Oil Filled with OLTC and all accessories including SITC of HT and LT bimetallic Terminal connections (Work includes fixing of Lugs, Ferrules etc of individual strands of each core with diagram for future reference ). (6.3MVA power transformer to be provided by department)
1
-
-
SITC of 12 Core 2.5 mm² Control cable copper Armored , 1.1 KV Grade, ISI, FRLS. (Work includes fixing of Lugs, Ferrules etc of individual strands of each core with diagram for future reference ).
120
-
-
SITC of 6 Core 2.5 mm² Control cable copper Armored , 1.1 KV Grade, ISI, FRLS. (Work includes fixing of Lugs, Ferrules etc of individual strands of each core with diagram for future reference ).
120
-
-
SITC of 2 Core 2.5 mm² Control cable copper Armored , 1.1 KV Grade, ISI, FRLS. (Work includes fixing of Lugs, Ferrules etc of individual strands of each core with diagram for future reference ).
240
-
-
SITC works for 11KV Switch Gear and yard works of 33/11KV Sub. Station.
-
-
-
SITC of 11 kV VCB Panel Board (12 kV, 1250A, 25 KA, Outdoor) (1+4)
1
-
-
SITC of 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets)
5
-
-
SITC of 11 KV 400mm2 single- Core XLPE cable (with one spare length) armored, FRLS
160
-
-
SITC of 11 KV 3-Core XLPE 300 mm² armored, FRLS
180
-
-
SITC of 11 kV Outdoor Heat Shrinkable Cable Termination Kits (08 No's) for single core cable 400mm sq
1
-
-
SITC of 11 kV Indoor/outdoor Heat Shrinkable Cable Termination Kits (suitable for 300mm sq 3 core)
8
-
-
SITC of 11 kV Isolator, double break,3-pole, 600Amp, horizontal mounting Type, with Earth Switch.
4
-
-
SITC of 9 Mtr. Long Pole(ST-410 SP33)
8
-
-
SITC of Galvanized iron of sorts
270
-
-
SITC of 100 KVA,11/0.433KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminum wound)
1
-
-
SITC of 120 mm² PVC LT Cable 4 Core, armored, FRLS
15
-
-
SITC of Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole
8
-
-
SITC works for Earthing of 100 KVA substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral Earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover.
1
-
-
SITC works for Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip
6
-
-
SITC of MCCB ‐ 200 Amps with LED phase indicators enclosed in mettle coated box CRCA thickness not less than 2mm out door type
1
-
-
Common MISCELLANEOUS works in 33/11 KV Sub. Station.
-
-
-
Cable Trench for laying of 11 kV XLPE / control Cables in the out door yard with cover plates of RCC or chequer plates (6mm Thick) (the Design / drawing / reinforcement / concrete mix will be as per standards adopted by deptt under REC / PMDP/DDUGJY)
25
-
-
33/11 kV Power Transformer Foundation (the Design / drawing / reinforcement / concrete mix will be as per standards adopted by deptt under REC / PMDP/DDUGJY)
1
-
-
33 kV Equipment Foundation & Gantry foundation (the Design / drawing / reinforcement / concrete mix will be as per standards adopted by deptt under REC / PMDP/DDUGJY)
1. REC/DDUGJY/33/11KV PSS/09 for 33kv VCB & CT (individual layout to be adopted)
2.REC/DDUGJY/33/11KV/PSS/10 ( for ISO)
3. REC/DDUGJY/33KV/02
(for any other kindly refer Drawings attached)
1
-
-
Providing and Laying of Earthing Mat (GI Flat 50 mm x8 mm) ( design to be adopted as per REC standard for the type of soil in that area )(Chemical Earthing if required will be done by contractor within quoted rate to get desired resistivity values required for rec stations )
1
-
-
SITC of Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip.
38
-
-
Providing and Laying of 33 kV Yard Concreting and Metalling with crushed stone aggregate of suitable dia required crushed out of Nalla boulder )
1
-
-
SITC of Yard lights (LED lights of 50W on 11 meter long octagonal galvanized GI poles) with RCC foundation and foundation bolts and MCB control on pole with under ground wiring using 6mm2 PVC copper wire from inside control room distribution panel to the pole.
1
-
-
Common MISCELLANEOUS equipment's for 33/11 KV Sub. Station.
-
-
-
SITC of a). Battery Bank 36 V,100 AH , of 18 No. cells of 2 V each, sealed maintenance free VRLA type, High impact Polyprophelene copolymer container, flame retardant.
b). 30v,100 AH , Float‐Cum‐Boost Charger With Full wave
rectification for 220 V, 1Phase, 50 HZ AC Input Supply .
1
-
-
SITC of Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
1
-
-
SITC of Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of Protection IP43. 200Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A),rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
1
-
-
Supply and laying of Rubber Mat 1mx2m 19mm thick
4
-
-
Supply of Fire Extinguisher Co₂ Type of 4.5 kg capacity for control room
6
-
-
Supply of 3 Sand Bucket Fire Extinguisher
1
-
-
Supply of Helmet (motorcycle Type with wind glass)
4
-
-
Supply of Rubber Gloves for 33 kV level
2
-
-
Supply of Rubber Gloves for 11kV level
2
-
-
Supply of Safety Belt
4
-
-
Supply of Safety Shoes heavy duty rubber sole
4
-
-
Supply of Earthing rod (set of 3 rods) (with telescopic rod of 5 Mtr detachable)
1
-
-
Supply of HV Detectors all voltages (50 hV with telescopic rod of 5 Mtr detachable)
1
-
-
Supply of Dell 3 in 1 Intel® Core™ i5-9500 (6 Cores/9MB/6T/3.0GHz to 4.4GHz/65W),Windows 10 Pro (64bit) English
(Dell recommends Windows 10 Pro for business),Intel® Integrated Graphics, 8GB 1X8GB 2666MHz DDR4 Memory, 2.5 inch 1TB 7200rpm SATA Hard Disk Drive, Ports & Slots with wireless Key board , mouse and double battery UPS ( to be delivered at Divisional Store)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements