Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Security and Emergency Services
Coronavirus COVID 19
Eprocure
Opening Date20 Apr 2021
Closing Date18 May 2021
Tender Amount₹ 24,02,430 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 58,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MES_437471_1Bid Award Id
ViewTender No
GE/AFU-14/2021-22Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking down old unserviceavle cable and Supply, laying, connecting and testing XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor rating 1100 volts grade of size 35 sqmm, 3.5 core, laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified Note: Neceesary Earth work, brick protection and sand cushioning shall be measured and paid for separately.
100
-
-
Taking down old unserviceavle cable and Supply, laying, connecting and testing XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor rating 1100 volts grade of size 10 sqmm, 2 core, laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified .
Note: Neceesary Earth work, brick protection and sand cushioning shall be measured and paid for separately.
250
-
-
Taking down old unserviceavle cable and Supply, laying, connecting and testing XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor rating 1100 volts grade of size 16 sqmm, 3.5 core, laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified .
Note: Neceesary Earth work, brick protection and sand cushioning shall be measured and paid for separately.
300
-
-
Taking down old unserviceavle cable and Supply, laying, connecting and testing XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor rating 1100 volts grade of size 25 sqmm, 3.5 core, laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified .
Note: Neceesary Earth work, brick protection and sand cushioning shall be measured and paid for separately.
200
-
-
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge.
Note: Punned thickness of sand shall be measured.
97.2
-
-
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
9600
-
-
M&L for LED street light driver 60 watt to 90 watt with universal voltage 90-300 volts alternating current ,short circuit,over temperature and over load protection complete including taking down old.
30
-
-
M&L for LED street light driver 120 watt to 150 watt with universal voltage 90-300 volts alternating current ,short circuit,over temperature and over load protection complete including taking down old.
30
-
-
M&L for 4 pole contactor Ie 63 Amps,Ue415 volts,Ui 1000 volts ,IS/IEC 60947-4-1 including auxilary contact Ie AC-15:4A 415 V- Ith 10/6 A all accessories complete including taking down old. Make: L&T /HavellLegrand
2
-
-
Taking out old rusted unserviceable GI tubing of any size and M&L new GI tubing 40mm bore light grade, as in protection pipe for passing through cable etc fixed on wall/poles or laid in trenches/ducts or across road including necessary clamps required complete all as specified.
40
-
-
Taking out old rusted unserviceable GI tubing of any size and M&L new GI tubing 50mm bore light grade, as in protection pipe for passing through cable etc fixed on wall/poles or laid in trenches/ducts or across road including necessary clamps required complete all as specified.
30
-
-
Taking out old rusted unserviceable GI tubing of any size and M&L new GI tubing 80mm bore light grade, as in protection pipe for passing through cable etc fixed on wall/poles or laid in trenches/ducts or across road including necessary clamps required complete all as specified.
60
-
-
Supply and fixing MCB Disribution board 1 row 3 modules of polycarbonate themoplastic, IP 65 dust proof, jet water tight corrosion proof, halogen & silicon free, with high quality earth and neutral links, internally embedded gasket for led and enclosures made PUR with cable glands and other accessories with MCB 6 amps and required terminals, metric size knock transparent door & with cable enerty covered and suitable to accommodate any make of MCCB and tested as per IEC 60439-3 (Flame retardant self extinguishing of size 202x238x111 mm complete all as specified and directed including taking down old. Make : Hensel cat Ref Nom: KV 7103/legrand/Schneider
150
-
-
Franklyn termination multi pointed copper rod,19/20mm dia and 500mm long with base plate of size 100 x 100 x 5mm fixed on top of roof of the building including drilling holes on copper strip and GI Pipe as required for making system for attaching complete all as specified and as directed by Engineer-in-Charge on buildings having height upto 6 mtr.
Make: Dhruva Cat Part No:Pro FR -1615C or equivalent in ASHLOK SAFE EARTHING/PRAGATI.
Note:-The rates quoted shall be deemed to include for scaffolding, saftey measures and insurance of workmen etc. and nothing extra shall be admissible on this account.
50
-
-
Taking down copper/Aluminium strip from buildings of height between upto 25 metres all as specified and directed.
1500
-
-
Copper strip 20 x 3.15 mm size burried in ground/fixed on wall and roof as roof/down conductor fixed with the help of porcelain insulator saddle and screws (fixed at 01 mtr interval) upto 25 metres height complete all as specified and as directed. Note: Porcelain insulators shall be measured and paid for seprately under relevant item of BOQ.
1500
-
-
Heavy duty porcelain/poly carbonate insulators of size 32 x 32mm to be fixed on wall/roof/pipe for laying of copper strip as roof/down conductor on building of height between upto 25 metres including nuts & bolts of brass of appropriate size all as specified and as directed by Engr-in-Charge including taking down old unserviceable.
500
-
-
Brazing/welding of copper strip of size 20 x 3.15mm at each joint by overlapping of minimum 20mm of both strips which are laid as roof/down conductor on any height of building all as specified and as directed by Engr-in-Charge
600
-
-
Tubing, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or as stand alone pipe grouted in ground or laid flat above roof top for holding of Lightening arrestors or strip, pipe of size 40mm bore dia complete all as specified and as directed including taking down old unserviceable.
60
-
-
Tubing, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or as stand alone pipe grouted in ground or laid flat above roof top for holding of Lightening arrestors or strip, pipe of size 80mm bore dia complete all as specified and as directed including taking down old unserviceable.
60
-
-
Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws complete all as specified and directed including taking down old unserviceable.
100
-
-
Dismantling the existing earthing pit chamber made of PCC 1:2:4 type B-I (using 20 mm graded crushed stone aggregate) and cleaning the area including removal of broken PCC/excavated material and supply and fixing polypit chamber with polyplastic pit cover all as specified and as directed by Engr-in-Charge.
100
-
-
Supply and fix single pointed air termination copper rod , 12 mm dia, 300mm long complete all as directed and engineer-in-Charge.
40
-
-
Refixing of broken/loose copper strip 20 x 3.15 mm size fallen from wall or roof top including replacement of appropriate insulators to insulate the air termination and conducting strip from mounting pipe including making good the disturbed surfaces of wall or roof all as specified and as directed by Engr-in-Charge
100
-
-
Taking down air termination copper/Aluminium rod from roof of buildings (serviceable one for reuse) or (unserviceable one for crediting to contractor) from buildings of height upto 5 metres all as specified and directed.
90
-
-
THOR safe lightening Protection Rod, with side flash capture head (SLPH), ICMET certified confirming to NFC 17-102, CPRI certified for 40KA which is a free standing mast of appx 4.5 mtr height made of stainless steel, free standing OD 77mm, thickness 3.2 mm, base plate hole M16 12 Nos, to with stand wind speed of 180 KM/Hr and mast coupler, accessory box with in-built bus bar insulator and base plate for fixing on foundation using stainless steel nuts and bolts. The contractor shall provide down conductor of 70 sqmm copper cable properly thimbled with copper lugs on both sides from mast to earthing test point including dismantling the existing unserviceable.
Make : Ashlok's THOR 1.0 SLPR Mast or equivalent in Dhruva/Pargati
Note: Down conductor shall be measured and paid for seprately under relevant item of BOQ.
6
-
-
ALICE Digital ( Lightening impulse counter Electromechanical) for counting surge impulse , including taking down old unserviceable ,complete all as specified and as directed by Engr-in-Charge.
6
-
-
Down conductor using 25 sqmm single core copper cable both ends thimbled properly with copper Lugs, including taking down old unserviceable ,complete all as specified and as directed by Engr-in-Charge. complete all as specified and directed.
300
-
-
Down conductor using 16 sqmm single core copper cable both ends thimbled properly with copper Lugs, including taking down old unserviceable ,complete all as specified and as directed by Engr-in-Charge. complete all as specified and directed.
200
-
-
Earthing identifier marker of 25mm flat iron 3mm thick length of flat iron 75 mm long which is 60 cm above the Ground level and 15 cm length below the Ground level and fixed with and icluding PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) in post holes and the top of the flat iron parabolic/
semicircular/traingular/rectangular shape MS plate 1.25 mm thick of size 30 cm width and 20 cm height to be welded/fixing to the flat iron including two coats of synthetic enamel paint over a coat of primer on steel surface complete all as specified and directed by Engineer in charge including dismantling the existing unserviceable.
200
-
-
Writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30cm height all as specified with thick synthetic enameled paint over a coat of synthetic enamel paint as base of writing letters all as specified.
300
-
-
Sheet metal enclosures for DBs SPN 2 way (when MCBs to be used) flush mounted including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / Schneider
20
-
-
MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 8 way SPN with 200 Amp rated bus bar 230 volt AC supply including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make:CAT PART NO:507682 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
20
-
-
MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 4 way SPN with 200 Amp rated bus bar 230 volt AC supply including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
25
-
-
MCB SPN 20 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
65
-
-
MCB single pole, 06 Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make:Legrand / HAVELLS / SIEMENS/Schneider
170
-
-
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through existing PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
200
-
-
M&L for insulated tape of size 25 mm width , 20 Meter long and 1 mm thick complete all as per directed.
300
-
-
Taking down old unserviceable lugs and M&L for Aluminium Lugs of size 25sqmm complete all as per specified and directed.
200
-
-
Taking down old unserviceable lugs and M&L for Aluminium Lugs of size 50sqmm complete all as per specified and directed.
100
-
-
Taking down old unserviceable lugs and M&L for Aluminium Lugs of size 70sqmm complete all as per specified and directed.
200
-
-
Taking down old unserviceable lugs and M&L for Aluminium Lugs of size 95sqmm complete all as per specified and directed.
150
-
-
Taking down old unserviceable lugs and M&L for Aluminium Lugs of size 120sqmm complete all as per specified and directed.
150
-
-
Taking down old unserviceable flexible pipe and M&L for flexible pipe of size 25 mm complete all as per specified and directed.
500
-
-
Taking down old unserviceable flexible pipe and M&L for flexible pipe of size 50 mm complete all as per specified and directed.
400
-
-
Taking down old unserviceableflexible pipe and M&L for flexible pipe of size 80 mm complete all as per specified and directed.
200
-
-
Taking down old unserviceable junction box and Supply, installing, testing & commissioning of street light Pole Box of 63 Amps, Three Phase four wire having four number aluminium bus bars including 6 Amps TP MCB. The box should have auto door lock facility with magnetic lock/manual having size 300 x 160 x 250 mm complete all as specified and directed.
Make :- DVEPL Cat Part No. NO.SLPBTP63 or equivalent in Hensel./Legrand
30
-
-
Taking down old unserviceable MCB box cover and M&L for MCB SPN box cover complete all as per specified and directed.
50
-
-
Taking down old unserviceable of any type of strip and supply and fixing of copper strip 32mm x 6mm with saddles and fixing screws etc for burried in ground to interconnect the earth pit to equipment room, all as specified and directed.complete with saddles and fixing screws for fitting the strip
200
-
-
Plain cement concrete 1:2:4, type B-1 ( using 20mm graded crushed stone aggregate ) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping of GI pipe/LA pole, bed plates, hold fast blocks, filling to pressed steel chowkat and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
5
-
-
M&L for road cutting and reapir as per site requirement including road patch complete all as per specified and directed.
10
-
-
MCCB four pole 415 Volts 50 Hz 100 Amps rating with rupturing capacity not less than 36 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
2
-
-
MCCB four pole 415 Volts 50 Hz 200 Amps rating with rupturing capacity not less than 36 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
5
-
-
MCCB four pole 415 Volts 50 Hz 250 Amps rating with rupturing capacity not less than 36 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
5
-
-
MCCB four pole 415 Volts 50 Hz 400 Amps rating with rupturing capacity not less than 36 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
5
-
-
MCCB four pole 415 Volts 50 Hz 630 Amps rating with rupturing capacity not less than 36 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
3
-
-
Supply & Fixing bus bar chamber and Weather proof outdoor bus bar chamber, made out of 1.6mm thick MS sheet comprising 4 Nos aluminium strips each of 300Amps, 60cm long duly insulated mounted on insulators incl MCCB 200 Amp complete with 4 No’s mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, including taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge. MAKE:HAVELLS/LEGRAND/SCHNEIDER
6
-
-
M&L for disconnecting and shifting of UPS and installing of UPS and connection including lugs ,wire as per site requirement all as per specified and directed.
2
-
-
Taking down old unserviceable of Hylam sheet/myca sheet and M&L for Hylam sheet /mica sheet as per site requirement complete all as per specified and directed.
30
-
-
Taking down old unserviceable of cable root marker and M&L for cable root marker as per site requirement complete all as per specified and directed.
100
-
-