Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date19 Sep 2024
Closing Date9 Nov 2024
Tender Amount₹ 59,82,000 
Notes
Download

Costs

Summary

Completion Of Incomplete Left Over Work Construction Of Storage Shed For Bso Yard (for Ge N And Ge S) Under Ge (north) Udhampur

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III) (SEC-II) SCHEDULE `A' PART-III, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.

-

-

-

... More
Slim linear LED lighting fixture 18/20 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge. Note:- A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE.

20

-

-

... More
Slim linear LED lighting fixture 10/12 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge. Note:-A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE.

2

-

-

... More
MCB SPN 6 to 40 Amps ( ISI Marked) 50 C/S 10 KA 'B' sereis complete all as specified and directed.

3

-

-

... More
MCB SP 5 to 32 Amps ( ISI Marked) 50 C/S 10 KA 'B' sereis complete all as specified and directed.

20

-

-

... More
MCB 63 Amps, TPN 415 volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable,fixed in repairs, complete all as specified and as directed by Engr-in-Charge

2

-

-

... More
Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 2.5 Sqmm (1x2.5sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 2.5 Sqmm (1x2.5 sqmm ) cable and one metre of conduit will be measured as one unit.

60

-

-

... More
Exhaust fan AC single phase 230/240 V of size 300mm sweep with louver speed 900-950 RPM power input 50-55 W, Heavy duty, complete all as specified and as directed by Engr-in-Charge. Make : Crompton -EXHD300-6-1/Havells-Turbo force SP/Khaitan-HD Exhaust fan or equivalent makes given in PS.

1

-

-

... More
Sub Total

-

-

-

... More
PATH (SCHEDULE 'A' PART-IV) Lump sum price worked out by the Contractor for “PATH” as listed in Schedule ‘A’ Part- IV.

1

-

514855.38

... More
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-V)(SEC-I) Lump sum price worked out by the Contractor for “External electrification” as listed in Schedule ‘A’ Part- V.

1

-

39290.84

... More
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-V) (SEC-II) SCHEDULE `A' PART-V, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.

-

-

-

... More
Supply and fixing LED Street Light fitting 18/20 Watt, New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 with acrylic, powder coated, pressure die cast aluminium compact high power LED tube light with heat resistant toughened Glass, Corrosion resistant, isolated driver low heat generating LED (Make of LED shall be CREE/Necia/Osram) including nuts, bolts, washers with suitable size/dia 40mm GI pipe bracket for fixing of street light including making all connection, complete all as per the direction of Engg-in-Charge. Note: A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE.

12

-

-

... More
Sub Total

-

-

-

... More
EXTERNAL WATER SUPPLY (SCHEDULE 'A' PART-VI) (SEC-I) Lump sum price worked out by the Contractor for EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part- VI.

1

-

30836.9

... More
EXTERNAL WATER SUPPLY (SCHEDULE 'A' PART-VI) (SEC-II) SCHEDULE `A' PART-V, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.

-

-

-

... More
Cutting and screwing existing steel tubing of 80 mm dia for alterations or additions, or lengthening screw on pipe to form connector, necessary done in position without taking down complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Construction of valve pit chamber of size i.e. 60 cm X 60 Cm X 60 Cm (internal dimmensions) including excavation& earth work of any type of soil, Brick work with sub class 'B' bricks in CM (1:6), 15mm thick internal plaster (1:6) and flush pointed as work proceed on external surface. M.S Cover made out of angle iron frame of angle iron 40mm X40mmX 6mm size including fixed with 3mm thick M.S Sheet including 2Nos handles and painted with 2-coat of synthetic enamel paint over one coat of red oxide primer, complete all as specified and as directed. all as per Drawing No. CEUZ/TD/1500/15 Sheet No. 1/1.

1

-

-

... More
Sub Total

-

-

-

... More
SEWAGE DISPOSAL (SCHEDULE 'A' PART-VII) Lump sum price worked out by the Contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part- VII

1

-

41842.19

... More
SEWAGE DISPOSAL (SCHEDULE 'A' PART-VII) (SEC-II) SCHEDULE `A' PART-VII, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.

-

-

-

... More
Construction of septic tank suitable for 10 users (single chamber) with inlet chamber, complete all as shown on drawings and specified.

1

-

-

... More
Construction of soakage well of size 1.8m dia and 3.0 m effective depth with intercepting chamber, inlet pipe and screen chamber, complete all as shown on drawings and specified.

1

-

-

... More
Sub Total

-

-

-

... More
PROTECTIVE WORKS (SCHEDULE 'A' PART-VIII) Lump sum price worked out by the Contractor for “PROTECTIVE WORKS” as listed in Schedule ‘A’ Part- VIII.

1

-

448675.35

... More
AREA DRAINAGE (SCHEDULE 'A' PART-IX) Lump sum price worked out by the Contractor for “Area Drainage” as listed in Schedule ‘A’ Part- IX.

1

-

162248.7

... More
EARTH WORK AND SITE CLEARANCE (SCHEDULE 'A' PART-X) Lump sum price worked out by the Contractor for “Earth work and site clearance” as listed in Schedule ‘A’ Part- X.

1

-

93813.25



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.