Military Engineer Services Tender
... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Eprocure
Opening Date12 Nov 2024
Closing Date10 Dec 2024
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683428_1Bid Award Id
ViewTender No
GEAFU-54/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINTENANCE OF FIRE ALARM SYSTEM, SMOKE DETECTORS, FLAME PROOF LIGHT, AVIATION LIGHT, HANGER LIGHT AND FITTING/ FIXTURES ALONGWITH CERTAIN MISC WORK AT VARIOUS LOCATION OF 39 WING AT AF STATION UDHAMPUR
BOQ Items
... More
S&F in repair of conventional fire alarm panel the following technical specifications complete all specified and directed by Engr-in-Charge. Note : (a) Oprating voltage : Between 15-30 volts DC peak
(b) Max Stand by current : less than 1mA
(c) Alarm LED current : max 1 mA
(d) Operating Temp :- 100 C to +550 C
(e) humidity : 0 to 95% RH
(f) Wiring : 2 core
(g) Protective transparent flip cover to prevent accidental activation
(h) Electonic Addressing (j) Blinking LED for visual supervision
(k) No frangible glass
(l) Stable Communication with noise immunity
(m) Automatic device Mapping. (n) Alarm flag for fast alarm reporting.
3
-
-
... More
Supply and fix in replacement of Smoke Detectors complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
45
-
-
... More
Supply and fix in replacement of Mother board (Addrassable type) Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
8
-
-
... More
Supply and fix in replacement of Mother board (Conventional type) Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
8
-
-
... More
Supply and fix in replacement of Hooter Conventional/addressable type Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
10
-
-
... More
Supply and fix in replacement of manual call point Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 including taking down complete all as specifeid and as directed.
15
-
-
... More
Servicing and cleaning of Smoke Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 as per existing and arrangement of ladder of suitable building height complete all as specifeid and as directed.
450
-
-
... More
S&F in repair of Remote response indicators addressable type including the following technical specifications complete all specified and directed by Engr-in-Charge.(a) Operating voltage : between 15-30 volts DC peak (b) Active average current : Less than 20 mA(c) Operating tem :- 100c to +550c(d) Humidity : 0 to 95% RH(e) Wiring : 2 core (f) Capable of high response (g) Real time response
5
-
-
... More
S&F in repair of Remote response indicators conventional type including the following technical specifications complete all specified and directed by Engr-in-Charge.(a) Operating voltage : between 15-30 volts DC peak (b) Active average current : Less than 20 mA(c) Operating tem :- 100c to +550c(d) Humidity : 0 to 95% RH(e) Wiring : 2 core (f) Capable of high response (g) Real time response
5
-
-
... More
Supply, laying & testing PVC insulated, PVC sheathed FRLS electric control cables (Heavy duty) with stranded copper fire serval cable conductor of size 1.5 sq mm ,2 core, 1100 Volts grade including taking down complete all specified and directed Engr-in-Charge. (Make: KEI/ Finolex/ RR cables/ Polycab/Havells)
350
-
-
... More
Supply and repair of Battery sealed accied as per existing size suitable for control panel 24 V DC (2 Nos of 12V, 7 SMF batteries )complete all as specified and as directed.
15
-
-
... More
M&L in repair of Explosion proof point wiring for for one light/bell/buzzer with 1.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid new steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 1.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, complete all as specified and directed.
45
-
-
... More
M&L in repair of Explosion proof point wiring for for one light/bell/buzzer with 1.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in rigid existing steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 1.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, complete all as specified and directed.
50
-
-
... More
M&L in repair of Explosion proof point wiring for for one light/bell/buzzer with 2.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 2.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, complete all as specified and directed.
45
-
-
... More
M&L in repair of Explosion proof point wiring for for one light/bell/buzzer with 2.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in rigid existing steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 2.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, complete all as specified and directed.
45
-
-
... More
M&L in repair of Explosion proof point wiring for for one light/bell/buzzer with 4.0 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid new steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 4.0 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, complete all as specified and directed.
15
-
-
... More
M&L in repair of Explosion proof point wiring for for one light/bell/buzzer with 4.0 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in rigid existing steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 4.0 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, complete all as specified.
25
-
-
... More
S&F in repair Explosion proof rotary switch single pole on and off with cable termination box of 16 Amps rating 250 Volts Class E EX II C suitable for class I Zone I, all as specified.
95
-
-
... More
Supply and fix in repair of Explosion proof rotary switch single pole on and off with cable termination box of 16 Amps rating 250 Volts Class E EX II C suitable for class I Zone I, all as specified.
90
-
-
... More
M&L in repair of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amps, 250 Volts, 2P+earth all as specified.
90
-
-
... More
S&F in repair of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amps, 250 Volts, 2P+earth all as specified.
40
-
-
... More
M&L in repair of Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of heavey duty steel conduit drawn through concealed steel conduit and connected to main board and making good disturbed surface complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
250
-
-
... More
M&L in repair of Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of riged existing steel conduit drawn through steel conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith steel conduit shall be considered as 1 running metre for payment purpose.
240
-
-
... More
M&L in repair of Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of heavey duty steel conduit drawn through steel conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 6.00 sqmm main cable and one RM of 6.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
250
-
-
... More
All as per Sl item No 26 but of size 6.00 sqmm drawn into 20/25mm riged existing steel conduit pipe (nominal area) and of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire.
Note: Two runs each of 6.00 sqmm main cable and one RM of 6.00 sqmm cable as earth wire together shall be considered as 1 running metre for payment purpose.
150
-
-
... More
All as per Sl item No 26 but of size 10.00 sqmm but heavey duty 20/25mm steel conduit pipe (nominal area) and of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire.
Note: Two runs each of 10.00 sqmm main cable and one RM of 10.00 sqmm cable as earth wire together shall be considered as 1 running metre for payment purpose.
150
-
-
... More
S&F in repair LED light fitting 2x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
35
-
-
... More
S&F in repair LED light fitting 1x20 Watt flame proof, CMRI certified commended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
25
-
-
... More
S&F in repair LED light fitting 40 Watt 4 Feet flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
32
-
-
... More
S&F in repair of Flame proof Flood light fitting 150 watt LED With IP65 degri of protation with reflector wire guard 150 watt LED ,complete all as specified and direcetd.
5
-
-
... More
Supply and replacement of Flame proof LED 70W with IP 65 degree of protation with reflector &wire guard light fitting ,complete all as specified and direcetd.
5
-
-
... More
Supply and replacement of Flame proof LED 60W with IP 65 degree of protation with reflector &wire guard light fitting ,complete all as specified and direcetd.
5
-
-
... More
M&L for taking down existing Flame Proof Weather Proof tube Light Fitting 1x20/40 Watt rod of any type including taking out Starter, Tube Rod 20/40 Watt and Providing New LED rod 1x20/ 40 Watt Complete with Glass of Make Borosil with Electric Connection and Connector, complete all as specified and as directed.
65
-
-
... More
M&L for taking down existing Flame Proof Weather Proof Tube Light Fitting 2x40 Watt rod of any type and Make including taking out Starter, Tube Rod 20/40 Watt and Providing New LED Light rod 2x40 Watt Complete with Glass of Make Borosil with Electric Connection and Connector complete all as specified and as directed.
45
-
-
... More
Taking out burnt/damaged copper winding wire from 1200/1400mm Sweep Flame proof ceiling fan motor of any make and M&L for rewinding of ceiling fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing capacitor, ball bearing, bush,locking pin and certain minor repair etc assembling and testing and refixing of same places complete all as specified & directed.
10
-
-
... More
Taking out burnt/damaged copper winding wire from 400/600mm Sweep Flame proof Exhaust fan motor of any make and M&L for rewinding of ceiling fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing capacitor, ball bearing, bush,locking pin and certain minor repair etc assembling and testing and refixing of same places complete all as specified & directed.
10
-
-
... More
Supply and fixing Flame proof with explosion protection distribution board encloser TPN 8Way Lighting Distribution Panel complete with appropriate size With internal bus bar and neutral link suitable wiring to terminal for class 1 Zone 1 & Ex IIC suitable for & including following accessories : (Enclosure Size 480x480x250mm)
(i) MCB 4P 63 Amps - 01 Nos (Incoming ) (ii) MCB SP 6 Amps -12 Nos (with complete internal Bus BAR &Wiring up to terminals.
2
-
-
... More
Supply and fixing Flame proof with explosion protection distribution board encloser TPN 8Way Lighting Distribution Panel complete with appropriate size With internal bus bar and neutral link suitable wiring to terminal for class 1 Zone 1 & Ex IIC suitable for & including following accessories : (Enclosure Size 420x420x250mm)
(i) MCCB 4P 63 Amps - 01 Nos (Incoming ) (ii) MCB SP 6 Amps with rupturing capacity 10KA - 01 Nos
2
-
-
... More
S&F in repair of Flame proof MCB Socket & plug combined 250V 32 AMPS 4P+Earth complete all as specifeid and as directed
5
-
-
... More
S&F in repair of Flame proof MCB Socket & plug combined 250V 63 AMPS 4P+Earth complete all as specifeid and as directed
5
-
-
... More
S&F in repair of Flame proof FH/199 FLP/WP flexible Metalic Conduit in SS304-3000MM Length with3/4" ET(M)X3/4" ET complete all as specifeied and asd directed.
100
-
-
... More
S&F in repair of Flame proof JB/104 FLP Junction box(to be used as incpection Elbow) complete all as specified and as directed.
25
-
-
... More
S&F in repair of Flame proof CG/209- FLP/WP3/4" ET 17.50mm OD DC bras Nickel plated Cable Gland complete all as specified and as directed.
25
-
-
... More
S&F in repair of Flame proof ACC/2019 FLP/WP Bends for conduit with3/4" ET entries complete all as specified and as directed.
25
-
-
... More
S&F in repair of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amps, 250 Volts, 2P+earth all as specified.
15
-
-
... More
S&F in repair of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amps, 250 Volts, 2P+earth all as specified.
15
-
-
... More
S&F in repair of MS Nipple BSP 175 MM/3/4" as per existing firring /DBs complete all as specified and as directed.
35
-
-
... More
S&F in repair of alluminium alloy/ cast iron Neoprene Gasket degree of protetion IP65 and fixing-in -repairs complete all as specified and as directed .
25
-
-
... More
S&F in repair of of MS Nipple conduit 175 MM/3/4" as per existing firring /DBs complete all as specified and as directed.
25
-
-
... More
S&F in repair recess on wall ERW Conduit of size 20 mm, ISI marked, heavy duty with all Conduit Accessories and Making Good Surfaces to match the Exiting Treat-ment (as per Site requirement) including complete all as per specified and as directed.
250
-
-
... More
S&F in repair of Electronic Hotter three phase Dynamically Balanced Siren including electric connection range of Hooter 1.5KM minimum Complete all as specified and as directed.
2
-
-
... More
Taking down existing hooter and Taking out burnt/damaged copper winding wire from Hooter motor of any make and M&L for rewinding of Hooter motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing capacitor, ball bearing, bush,locking pin and certain minor repair etc assembling and testing and refixing of same places complete all as specified.
2
-
-
... More
Supply and fixing of Electronic Hotter single phase Dynamically Balanced Siren including electric connection range of Hooter 1.5KM complete all as specified and specified and as directed.
2
-
-
... More
Supply and fix in repair of Integral LED aviation light luminaire in yellow die-cast aluminium alloy housing with red coloured polycarbonate dome of including necessary electric connection with suitable size of PVC copper cable as per manufacture's requirement and building /tower height up to 30mtr complete all as specified and as directed by Engineer-in-Charge.
15
-
-
... More
Taking down unserviceable hanger lights from the hight of approx up to 25 mts from ground lavel including electric connections and supply and fixing hangers lights 150 W Energy saving environment friendly & robust /Highbay LED Luminanire high high efficancy (150lm/W) ip 66 with toughened glass industrial applications,including necessary electric connection, removing of wire net /mesh and refixing of wire mesh/net and making good condition complete all as specified and directed by Engr-in-charge. CAT No HLPLEDHB150 NCW of HPL /Wipro /Philips/Crompton/Havells
45
-
-
... More
M&L Wiring for two single core 2.5 sqmm copper conductor PVC insulated PVC sheated as per is 694 up to date all including drawing through PVC Conduit one earth wire making connection with LED Building security Light/ tower light / fitting etc complete all as specified and as directed by enginer in charge .Note : Light fitting shall be conected by taping the two core cable with pvc/bakelite electrical connector. Connectors shall be installed/inseated /enclosed inside the conduit /box cost shall be deemed to be included in quoted rates
350
-
-
... More
S&F in repair Sheet metal enclosures for DBs 2 way (when MCBs to be used) flush mounted including accessories therein and disposing off complete all as specified and directed.
10
-
-
... More
S&F in repair MCB SPN 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including accessories therein & disposing from site complete all as specified and as directed.
10
-
-
... More
Servicing of Solar water heater Descaling of solar Collectors plate connected to solar water heater of various capicty(by circulating desclaing solution/agent for 20-30 miniute),cleaning entire surface (dismaintiling of plates shall be carried out if requied including fixing soldering requied)and cleaning of tank of capicity 100/200/300/400 LPD by solar descaling (such as mild acidic solution vinegaretc) solution/agent including drain out all Scales dust, dirt by pressure pipe Cleaning& replacement of U/S drain plug along with all requied work such as welding,theriding etc complete all as specified and as directd
45
-
-
... More
S&Fix in repairs Evacutated tube collector type 100 ltrs solar water heater(MNRE approved) along with GI storage tank of suitable capicity on iron angle stand applying watre sealent around stand fastners including dismaintaling of old unserviceable solar water heater complete as specified and directed.
2
-
-
... More
S&Fin repairs Evacutated tube collector type 200 ltrs solar water heater(MNRE approved) along with GI storage tank of suitable capicity on iron angle stand applying water sealent around stand fastners including dismaintaling of old unserviceable solar water heater complete as specified and directed.
2
-
-
... More
S&Fin repairs Evacutated tube collector type 300 ltrs solar water heater(MNRE approved) along with GI storage tank of suitable capicity on iron angle stand applying watre sealent around stand fastners including dismaintaling of old unserviceable solar water heater complete as specified and directed.
1
-
-
... More
Supply and replacement Solar water system flat plate collactor with heat exchanger (MNREapproved) type suitable plate size for existing plate complete all as specified and as directed.
2
-
-
... More
Supply and fixing in replacement of old unserviceable water tank of flate plate solar water heater/Evacuated tube solar water heater capicity 100/200/300/400 LPD along with all connecting items like nut,bolte gasket,soldering welding complete all as specified and as directed.
6
-
-
... More
Supply and fixing of in replacement of old unserviceable tube /Evacuated tube solar water heater capicity 100/200/300/400 LPD along with all connecting items like nut,bolt gasket,soldering welding complete all as specified and as directed.ed.
35
-
-
... More
M&L for clading of insulated rubber(rockwool/mineral wool/fibre glass wool)as per fixed on site including one layer of aluminium sheet/flakes cover on outer/air vent of solar water heater GI pipe 20mm in a minimise any type of heat losses complete all as specified and as directed by Engineer in charge.
65
-
-
... More
Supply and repair unserviceable EPDM sheet including requied nut bolt and washer set at both end used for jointing two flate collector/at end of solar flat plate collector(Medium pressure flexible silicon/rubber hose suitable for hot water of suitable size along with tighting clips wherever requied instead of EPDM sheet) for arresting the leakage complete all as spcifeid and as directed.
150
-
-
... More
Suppply and fix in repair heating Heating Element 3000Watt alongwiith thermostat of sitable shape and size fitted in solar water tank any capicity conforming to ISI mark with ruber washers and clamps complete all as specified and as directd by Engr in chare
15
-
-
... More
Suppply and fix in repair heating Heating Element 2000Watt alongwiith thermostate of suitable shape and size fitted in solar water tank any capicity conforming to ISI mark and ruber washers with clamps complete all as specified and as directd by Engr in charge
20
-
-
... More
M&L for dismantling old unserviceable tank in replacement with new Rotational moulded polyethylene water storage tanks of capacity 500 ltrs three layered (Cylindrical vertical with closed top) hoisted and fixed in position including ball cock brass of size 20mm dia with polythene ball and inlet, outlet including wash out with plug/over flow pipe and anti mosquito rose coupling at one end all as specified in SSR Pt-I complete all as specified and as directed .
9
-
-
... More
M&L for dismantling old unserviceable tank in replacement with new Rotational moulded polyethylene water storage tanks of capacity 1000 ltrs three layered (Cylindrical vertical with closed top) hoisted and fixed in position including ball cock brass of size 20mm dia with polythene ball and inlet, outlet including wash out with plug/over flow pipe and anti mosquito rose coupling at one end all as specified in SSR Pt-I complete all as specified and as directed .
5
-
-
... More
M&L for cross arms brasings supports clamps and back plates fabricatd from structural steel sections including nuts,bolts washers welding bending cold or hot drilling holes for bolts in any type shape or size as indicated or directed and provn of two coat systhic enamed part over a coat of red oxide primer complete primer all as specifed and as directed
1
-
-
... More
Suppply and fixing in replacement of Stem type thermostate with switch/nob suitable for solar water heater complete all as specified and as directed
15
-
-
... More
Supply and fix in repair Steel water tubing medium grade galvanised ( ISI marked) with all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc) complete all as specified of following sizes:-
-
-
-
... More
25 mm dia
102
-
-
... More
20 mm dia
96
-
-
... More
S& F in repair Gun metal globe or gate valves 20 mm cast iron wheel head screwed both ends for iron pipe and fixed type complete all as specified and as directed.
13
-
-
... More
S& F in repair Gun metal globe or gate valves 25mm cast iron wheel head screwed both ends for iron pipe and fixed type complete all as specified and as directed.
10
-
-
... More
Taking down existing Hanger door motor and disconnecting of copper winding wire from Hanger door motor up to 3 HP of any make and M&L for rewinding of motor with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing capacitor, ball bearing, bush,locking pin and certain minor repair etc assembling and testing and refixing of same places complete all as specified & directed.
2
-
-
... More
Supply ,Instalation Commissining & testing of LT Control Panel For Motorized gate control of approprite size Made of CRCA Sheet of 2 mm indoor type thickness incl cleaning and finishing complete with powder coated in approved shed having connection/ inter connection with adequate size copper wire link connector and terminal block etc alongwith necessary nut and bolts clips etc mounted on wall duly painted as complete directed by Engr in Charge
Main Circute Breaker
(a) MCB 32-40 Amps 3 Phase curve 415 volt
(b) Indication lamp 1 set
Contactor
(a) Power AC Contactor 40 Amps 3 core
(b) Over load relays range 6-14 Amps
(c) Indicating lamp for indicate following:-
(i) Forward running 01 No
(ii) Reverse running - 01 No
(iii) Forward/reverse/stop push button to be provided on the front door 01 No (iv) Speed Controler As per Existing Model (v) Single Phase Preventer (vi) DOL Starter for 3 HP Motor
2
-
-
... More
Supply and fix in repair Flexible cable PVC insulated PVC Sheathed 3 Core 2.5 sqmm for Motor to control panel Connection suitable as per existing complete all as specifeied and as directed.
180
-
-
... More
Supply and fix in repair MS Plate at Hanger door all specifed &Direction by Engr in Charge complete all as specifeid and as directed.
50
-
-
... More
Supply and fixing in repair 6 mm MS Plate for working on rolling wheel for moving to gate complete with Gear pully,Gear box Belt , including welding,cutting as per existing size etc and greasing complete all as specified and as directed by Engineer In charge
10
-
-
Evaluation Notes How It Works ?