Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date27 Apr 2021
Closing Date24 May 2021
Tender Amount₹ 13,20,179 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MES_438831_1Bid Award Id
ViewTender No
GE/U(N)-07/2021-22Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for Point wiring for One light point controlled by one one way switch 5 Amp with 1.5 Sqmm single core multi standed copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia and1.5mm wall thickness ISI marked terminated into annealed steel terminal boxes including 3.00 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed by the Engr-in-charge.
900
-
-
M&L for point wiring with 1.5 Sq. mm PVC Insulated unsheathed FRLSH multistranded copper conductor, medium grade ISI meraked drwan into and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drwan in to and including suraface PVC rigid non metalic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continious earth wire connected to common earth dolly complete all as specified and directed by engineer incharge.
150
-
-
All as per item No. 04 above but for bell / buzzer on independent board controlled by one push button bell switch.
50
-
-
All as per item No. 04 above but for one 5 Amps socket outlet on independent board.
250
-
-
All as per item No. 04 bove but wire size 2x2.5 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLSH 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
300
-
-
All as per item No. 04 above but controle by 2 Nos.of two way switch.
10
-
-
All as per item Srl No. 04 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr -in-charge.
150
-
-
M&L Point wiring with multistranded copper conductor cable, PVC insulated and unsheathed (FRLSH) size 1.5 sqmm drawn in and incl PVC casing and caping with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for one light /fan/controlled by one switch with thickness not less than 1.25mm annealed steel boxes concealed on wall with and including 3mm thick laminated backlite sheet complete all as directed by Engineer-in-charge.
150
-
-
All as per item No 11 above but for two way point wiring
1
-
-
All as per item No 11 above but for one 3/5 pin socket 5 Amp on same board.with cable1.5 sqmm size.
15
-
-
All as per item No 11 above but for one 3/5 pin socket 5 Amp on independent board.with cable1.5 sqmm size.
150
-
-
All as per item No 11 above but for 3/5 pins socket outlet 15 Amps independent with 2.5 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
200
-
-
All as per item No. 11 above but for bell / buzzer on independent board controlled by one push button bell switch.
2
-
-
S&F Switch Piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge.
1765
-
-
S&F Switch Piano flush type single pole two way 5 Amps, all as specified and directed by Engineer- in - Charge.
22
-
-
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type complete all as specified and directed by Engineer- in - Charge.
565
-
-
S&F Switch Piano type single pole 16/20 Amps One way, complete all as specified and directed by Engineer- in - Charge.
500
-
-
S&F Socket outlet Two in one, 3/5 Pin piano type 10 Amp and 20 Amp flush type complete all as specified and directed by Engineer- in - Charge
500
-
-
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as specified and directed by Engineer - in - Charge.
755
-
-
S&F Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by engineer in charge
52
-
-
S&F switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer- in - Charge.
52
-
-
S&F Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked complete all as specified and directed by Engineer- in - Charge.
165
-
-
Fixing only serviceable light fittings any type as obtained against item No 2 all as specified and directed by engineer incharge
590
-
-
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
165
-
-
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 27
165
-
-
M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :-
(a) Excavation and earth work for drilling hole for electrode in any type of soil.
(b) PCC Pit in cement concrete 1:2:4 type B-1.
(c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.
(d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering.
(f) Requisite quantity of common salt and charcoal.
(g) Testing of Earthing.
Note : (a) On testing after completion of earthing, if the desired earth resistnace is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the engineer incharge.
(b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
10
-
-
Sub main wiring with two run single core 6 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, junctgion boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continious earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge.
Note : Two run of 6 sqmm and one run 6 sqmm cable and one run of PVC conduit shall be measured as one RM
300
-
-
M&L in replacement for submain wiring with 2X4QMM+1X4SQMM Earth Wire single core PVC insulated FRLSH sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC Concealed Conduit 25MM DIA complete including taking down userviceable submain wiring all as per site requirement and direction by EIC, all accessories complete all as specified and directed.
400
-
-
M&L in replacement for submain wiring with 2X1.5QMM+1X1.5SQMM Earth Wire single core PVC insulated FRLSH sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC Concealed Conduit 20MM DIA complete including taking down userviceable submain wiring all as per site requirement and direction by EIC, all accessories complete all as specified and directed.
800
-
-
M&L in replacement for submain wiring with 2X2.5QMM+1X2.5SQMM Earth Wire single core PVC insulated FRLSH sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC Concealed Conduit 20MM DIA complete including taking down userviceable submain wiring all as per site requirement and direction by EIC, all accessories complete all as specified and directed.
350
-
-
S&F Switch Piano flush type single pole two way 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
20
-
-
S&F Switch Piano flush type single pole 5 Amps one way fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
600
-
-
S&F switch piano flush type for bell Push 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
60
-
-
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
50
-
-
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp and 15 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
25
-
-
S&F Switch Piano type single pole 16/20 Amps One way, fixed in replacement, complete all as specified and directed by Engineer- in - Charge
25
-
-
S&F Switch socket combination piano type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge
650
-
-
S&F Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
650
-
-
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body fixed in replacement, complete all as specified and directed by Engineer - in - Charge.
25
-
-
S&F Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
400
-
-
S&F Electric bell(Ding dong) AC 230/250 volts grade single pole ISI marked fixed in replacement, complete all as specified and as directed by engineer in charge.
50
-
-
Fixing only serviceable MCB DB of any type and capacity obtained from Item No 03 complete all as specified and directed by engineer incharge.
10
-
-
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 8 Way all as specified and directed by engineer in charge.
20
-
-
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 12 Way all as specified and directed by engineer in charge.
15
-
-
S&F in replacement Distribution board 4 way TP&N Double Door IP43-IK09 with metal door are fitted with Bus Bars, Neutral Links suitable for 415V, 50Hz, Blanking Plates, Suitable for TP/FP MCB all as specified and as directed by engineer incharge.
20
-
-
S&F in replacement Distribution board 6 way TP&N Double Door IP43-IK09 with metal door are fitted with Bus Bars, Neutral Links suitable for 415V, 50Hz, Blanking Plates, Suitable for TP/FP MCB all as specified and as directed by engineer incharge.
2
-
-
S&F MCB TPN 63 Amps four pole 415V incl all termnials, fitting etc all as specified and as directed by engineer incharge.
25
-
-
S&F connection and testing 'C' series SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA for lighting and other domesitc loads incl necessary copper lugs etc all as specified and as directed by engineer incharge.
195
-
-
Supply fixing, connection and testing 'C' series MCB SP6-32 Amps all as specified and as directed by engineer incharge.
175
-
-
Supply fixing connection and testing 'C' series MCB SP 40 Amps all as specified and as directed by engineer incharge.
350
-
-
Fixing only serviceable MCB SPN/SP any capacity obtained from item no 03 as above all as specified and as directed by engineer in charge.
30
-
-
S&F Modular fan step regulator 120W 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
40
-
-
S&FModular switch 01 way 06A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
50
-
-
S&F Modular switch 01 way 16A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
45
-
-
S&F Modular bell push flush type 6A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
15
-
-
S&F Modular socket, 6A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
45
-
-
S&F Modular socket, 6A/16A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
50
-
-
S&F PVC rectangular block for mounting switches, sockets, fan regulator etc. of 4 MODULE all as specified and as directed by engineer in charge,
20
-
-
S&F PVC rectangular block for mounting switches, sockets, fan regulator etc. of 6 MODULE all as specified and as directed by engineer in charge,
10
-
-
S&F 3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
10
-
-
S&F 3 mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
10
-
-
S&F for Isolator 4 Pole 100 Amp, 415 Volts- all as specified and as directed by engineer in charge.
10
-
-
S&F for Isolator 4 Pole 125 Amp, 415 Volts- all as specified and as directed by engineer in charge.
10
-
-
M&L for disconnecting all Electrical connection from MCB DB TPN/Wall Mounted Panel Box for reconnecting the same with providing proper Copper Bottle Lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire complete all as specified and directed by engineer in charge.
Note : Replacement Burnt out MCBs of any type/size may be measured and paidseparately under relavent Items
10
-
-
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase all as specified and directed by Engineer in charge.
Note : Cutting of Wall /Floor shall be measured and paid separately.
10
-
-
M&L for Cutting of hard standing n.exc 45 Cm defth, and n.exc 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing all as specified and as directed by engineer in charge.
100
-
-
S&F in repair rigid non- metalic PVC casing and caping of 25/12 mm inclusive of all elbow, tees, etc comlete all as directed by Engr- in- Charge.
100
-
-
S&F in repair LED PLL Lamps (Retro fit) 18 Watt all as specified and as directed by engineer in charge.
100
-
-
S&F angle lamp holder ,pvc / polycarbonate type with back plate suitable for batten fittings all as specified and directed by Engr-in- charge.
150
-
-
M & L for replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volt capacity complete all as directed.
60
-
-
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply single door SPN DB system 2 Way all as specified and directed by engineer in charge.
150
-
-
S&F in repair GI bend 15mm dia
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements