Military Engineer Services Tender
... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date22 Feb 2025
Closing Date15 Mar 2025
Tender Amount₹ 27,00,000
Costs
EMD
₹ 54,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_699093_1Tender No
CA NO GE/AFJ-78/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Description all as per item No. 3 here in before but for submersible pump & motor of capacity 15 to 25 HP all as directed.
1
-
-
... More
Description all as per item No. 3 here in before but for submersible pump& motor of capacity up to 7.5 HP all as directed.
1
-
-
... More
S&F MS column pipe 100 mm dia medium grade (heavy duty) flanged type including necessary fixing MS nut, bolt, washer & gaskets etc including groove for cable entry system of 3 mtr in length complete all as directed.
10
-
-
... More
M&L for servicing of hemisphere fountain including cleaning of fountain nozzles, adjustment of fountain nozzles for a precision effect, cleaning of pump suction wire mesh, testing of water proof luminaries, cleaning of toughened glass and heat resistant polyester/polycarbonate filter, tightening all electrical connections of control panel etc and testing of complete fountain installed at officer mess gate complete all as directed. (i) Any parts required to be replaced during servicing fountain shall be measured and paid for separately under appropriate item as "Supply only" of this schedule. However labour element involved in replacement is deemed to be included in quoted rates against this item.
(ii) Any minor repairs involved in servicing to make the fountain functional even if notified by the Engineer-in-Charge shall be carried out by the contractor without any extra cost to the department.
(iii) This item will be operated in every three month during the entire period of the contract and shall be measured seprately number of times the job is carried out.
2
-
-
... More
Description all as per srl item No. 7 here in before but for multiple jet fountain near Technical area gate and main gate,SNCO Mess all as specified and directed.
3
-
-
... More
Supply only ball fountains nozzles brass for hemispherical fountain along with repair complete all as specified and directed.
48
-
-
... More
Supply only contactor for pump MNX-25 all as specified and directed.
1
-
-
... More
Supply only timer and relay complete all as specified and directed.
1
-
-
... More
S&F water proof light luminaire for fountains make as per existing site all as directed by Engineer-in-Charge
15
-
-
... More
Supply, laying and testing PVC insulated and sheathed flat 3 core copper stranded conductor water proof submersible cable size of cable 10 sqmm fixed to submersible monoblock pump set to starter as directed including taking out old unserviceable cable complete all as specified and directed.
110
-
-
... More
Supply, laying and testing PVC insulated and sheathed flat 3 core copper stranded conductor water proof submersible cable size of cable 16 sqmm fixed to submersible monoblock pump set to starter as directed including taking out old unserviceable cable complete all as specified and directed.
120
-
-
... More
S&F of LED type aviation obstruction light 230 volt yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories.complete with internal wiring and connected to earthing and also taking down unserviceable aviation light fittings from overhead reservior complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
M&L for servicing / maintenance including repairs but excluding spares as required for following components of complete altoc dosing system installed at (a) pump house no 08 = 01 , (b) pump house no 11 = 01 , (c) pump house no 03 = 01 , (d) Kaluchak pump house = 01 , (e) Map pump house No1 = 01 (f) swimming pool = 01 including following operations:
(i) Dismantling of Altoc Dosing system complete part by part in MES yard/ workshop, cleaning of all the stationary and rotary parts,repairing to gear box and display the parts at site for inspection of Engr-in-Charge to ascertain the serviceability / unserviceability of plant and to ascertain the quantam of defects and repairs involved.
(ii) Transporting the defective parts to authorised dealer for repairs as decided by the Engnr-in-Charge and carrying out the needful repairs including replacement of defective unserviceable parts.
(iii) Assembling the Altoc Dosing System after repair/service and carrying out necessary test in presence of Engnr-in-Charge to establish functionability of the repaired plant upto the entire satisfaction of Engnr-in-Charge.
12
-
-
... More
Note:-
(i) Maintenance / servicing of each Altoc Dosing System shall be measured and paid maximum twice in every month. However, in case of unserviceability of the same, the contractor shall be required to carry out the job for its maintenance any number of times as required and directed at site as a case of emergency breakdown.
(ii) Any parts required to be replaced during repair / servicing of altoc dosing system shall be measured and paid for separately .
(iii) Any minor parts required to make plant serviceable even if notified by the Engr-in-Charge shall be supplied by the firm without any extra cost to the department.
-
-
-
... More
Supply only PVC dosing head assembly with suction and delivery adopter all as specified and directed.
2
-
-
... More
Supply only weighted suction line strainer 3/8 " all as specified and directed.
4
-
-
... More
Supply only 3/8 " white suction / discharge tubing all as specified and directed. .
18
-
-
... More
Supply only NRV (Non Return Valvae) for delivery line all as specified and directed.
4
-
-
... More
Supply only dosing agitator rod with fan,PP coating all as specified and directed.
4
-
-
... More
Supply only stater all as specified and directed.
4
-
-
... More
Supply only gear oil 460 all as specified and directed.
2
-
-
... More
Supply only PVC NRV set with glass ball for suction and delivery adopter all as specified and directed.
4
-
-
... More
M&L for rewinding of motor of induction motor up to 1 HP capacity insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed.
4
-
-
... More
Material and labour for disconnecting and removing the squirrel cage 3 phase 415 Volts, 50 Hz induction motor of following capacity from its foundations/ base frame by disconnecting electrical connections and motor couplers,taking it to workshop for repair and dismantling and opening up of motor ,removing burnt out winding wires complete,cleaning startor and rotor assembly, rewinding the startor with same guage and type with insulation copper conductor winding wires and insulation sheets,applying insulating varnish over the complete winding , drying up by heating ,assembling back the stator and rotor including replacement of terminal blocks and terminal bolts, nuts and washers,refixing back to its postion after getting repaired and making all connections, carry out alignment, testing for satisfactory function all as specified and as directed .
Note: (i) Bearings shall be measured and paid separately.
-
-
-
... More
10 to 20 Hp Capacity
2
-
-
... More
5 to 7.5 HP capacity
3
-
-
... More
Supply only anti friction heavy duty bearings suitable for 10 to 15HP motor all as specified and directed.
2
-
-
... More
Supply only anti friction heavy duty bearings suitable for 5 HP to 7.5 motor all as specified and directed.
4
-
-
... More
Supply only anti friction heavy duty bearings suitable for 2HP to 3HP motor all as specified and directed.
4
-
-
... More
M&L for cleaning of valve pit chambers removing grass,mud complete all as specified and directed by Engineer-in-Charge.
15
-
-
... More
M&L for painting on steel and iron surfaces of LT panel boards , MS pipes LT feeder pillar boxes over 10 cm in width including removing of old rust, carbon contents on surfaces by using wire brush, cleaning suitable preparation for repainting and applying two coats synthetic enamal (ordinary tint) paint of as approved colour over a coat of red oxide zinc chrome primer all as specified and directed.
50
-
-
... More
S&F iron foot valves size of 80 mm to 100mm and complete all as specified and directed by Engineer-in- Charge location such as under ground sump located No 1 Map , No 2 Map (officers accommodation), Kaluchuk all as specified and directed.
6
-
-
... More
Taking down old unserviceable starter and supply and install satr delta starter in sheet metal enclosure with three phase protection feature suitable for operation on AC, three phase four wire , 415 Volts, 50 Hz supply for Motor of capacity up to 40 HP with relay range 9-15Amps complete and directed by Engr- in-Charge .
2
-
-
... More
Supply only altoc GP calcium based granular disinfectant (Aqua Fit) for water treatment packing 45Kgs plastic drum all as specified and directed.
1800
-
-
... More
M&L for construction of masonary valve chamber of internal size 600x600x600mm with brick masonary set in cement mortar 1:6 over 100mm thick PCC (1:4:8) type D2 concrete foundation, 50mm thick PCC (1:2:4) type B1 in coping 15mm thick plaster in cm (1:4)m for internal surfaces of walls and externally upto 15cm below ground level, including MS sheet 3.15mm thick hinged cover with locking arrangements including lifting handle fixed to 50x50x6mm angle iron frame embedded in PCC coping including two coats of synthetic enamel paint to steel surfaces over a coat of red oxide primer including necessary excavation and earth work in any type of soil and removal of surplus excavated soil to a distance not exceeding 50mtr including dismantling of old broken valve pit chamber complete all as specified and diretcted.
12
-
-
... More
M&L for construction of masonary valve chamber of internal size 900 x 900 x 900 mm with brick masonary set in cement mortar 1:6 over 100mm thick PCC (1:4:8) type D2 concrete foundation, 50mm thick PCC (1:2:4) type B1 in coping 15mm thick plaster in cm (1:4)m for internal surfaces of walls and externally upto 15cm below ground level, including MS sheet 3.15mm thick hinged cover with locking arrangements including lifting handle fixed to 50x50x6mm angle iron frame embedded in PCC coping including two coats of synthetic enamel paint to steel surfaces over a coat of red oxide primer including necessary excavation and earth work in any type of soil and removal of surplus excavated soil to a distance not exceeding 50mtr including dismantling of old broken valve pit chamber complete all as specified and diretcted.
8
-
-
... More
Material and labour for construction of masonary valve chamber of internal size 1200 x 1200 x 1000 mm with brick masonary set in cement mortar 1:6 over 100mm thick PCC (1:4:8) type D2 concrete foundation, 50mm thick PCC (1:2:4) type B1 in coping 15mm thick plaster in cm (1:4)m for internal surfaces of walls and externally upto 15cm below ground level, including MS sheet 3.15mm thick hinged cover with locking arrangements including lifting handle fixed to 50x50x6mm angle iron frame embedded in PCC coping including two coats of synthetic enamel paint to steel surfaces over a coat of red oxide primer including necessary excavation and earth work in any type of soil and removal of surplus excavated soil to a distance not exceeding 50mtr including dismantling of old broken valve pit chamber complete all as specified and diretcted.
18
-
-
... More
Supply and fixing cast iron flanged butterfly valve including taking down old unserviceable valve of size 150mm dia complete all as specified and directed by Engineer-in-charge
5
-
-
... More
S&F of CI pipes 150 mm dia suitable for and including leather gasket with nut, bolts, washers etc for overhead water tank of 20m staging including taking up or down old unserviceable water mains (including all fittings) of any type including burning out joints, turning water OFF or ON as necessary and taking off and refixing covers, access doors etc. and with and including necessary flanged joints, nuts & bolts, rubber gasket etc complete all as specified and directed by Engr-in-Charge.
72
-
-
... More
Supply,laying,testing & commissioning of UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm, 4 core, with suitable thimbles complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
190
-
-
... More
M&L for dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. Note:- Only punned thickness shall be measured for payment purpose.
8.91
-
-
... More
M&L for sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable, complete all as specified and directed.
0.9
-
-
... More
Excavation in trenches n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth and getting out in soft/loose soil all as directed by Engr-in-Charge.
34.43
-
-
... More
Returning filling in including spreading levelling and well ramming in n.exc. 25 cum complete all as directed by Engr-in-Charge.
14.15
-
-
... More
Removing the excavated material n.exc. 50m and depositing where directed at & level n.exc. 1.5m above the starting point all as directed by Engr-in-Charge.
20.27
-
-
... More
Repairing & treatment of overhead tank with approved chemical coating/compound mixed with appoxi chemical for fixing leakage, pluging holes and repairing crack of whole tank as per site requirment all as per directed by Engr-in-Charge.
3
-
-
... More
Repairing & treatment of under ground tank with approved chemical coating/compound mixed with appoxi chemical for fixing leakage, pluging holes and repairing crack of whole tank as per site requirment all as per directed by Engr-in-Charge.
4
-
-
... More
M&L for repairing of iron stair with welding work of PCC overhead tank approx height 18-20 meter with solid welding and replacement of iron bar as per existing site at pump house No 8 & 11 all as per work done directed by Engr-in-Charge.
2
-
-
... More
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
15
-
-
... More
M&L for PCC 1:3:6 type C-2 using 20mm graded crushed stone aggregate as in pole pole foundation, coping, stay pits etc including provision of necessary form work to achive fair finishes surfaces, complete alal as specified and directed.
30
-
-
... More
Supply and fixing in replacement direct-on-line starter in sheet metal enclosure for motor rating 415 Volts, 3 phase, 50 Hz, 9-14 Amps relay maximum range of capacity 7.5 HP complete all as specified and as directed.
2
-
-
... More
M&L for pumping out completely existing dirty water from hemisphere fountain pool at Officer Mees gate and cleaning the fountain pool throughly by brushing, removing ugly spot, algaue by using acid or harpic and finally washing with bleaching powder to entire satisfication of Engr-in-Charge.
Note:-
i) For pumping, water pump shall be arranged by the contractor including necessary electrical connections as required at site.
ii)T&P, material, labour, element involved in cleaning shall be carried out by firm without any extra cost to the department.
iii)The item will be operated once in every month during the entire period of the contract and shall be measured seprately number of times the job is carried out.
3
-
-
... More
Description all as per srl item No. 54 here in before but for Multiple jet fountain near Technical area gate all as specified and directed.
3
-
-
... More
Supply only contactor for pump MNX-70 for pump House No-8 & 11 all as specified and directed.
3
-
-
... More
S&F pressure pump/booster pump 0.5 HP for single building of Offr Accn all as specified and directed.
2
-
-
... More
Supply only timer and relay As per irem No-57 all as specified and directed.
15
-
-
... More
Taking out unserviceable water level controller and repair replacement of water level controller all as specified and directed.
2
-
-
... More
Supply, installation, testing and commissioning of DECRIN DOSING PUMP high pressure single head geared motored adjustable dozing pump including complete accessories lead tubing, connecting nuts, injection check valves, clay weight and ferrules complete all as specified and directed.
1
-
-
... More
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%