Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Aug 2024
Closing Date28 Sep 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Summary

Repair/maint Of Underground Elect Cable,lt Panel, Lt Line And Connected Work At 57 Weu, 874 Alongwith Connected Units In Aor Of Rac Section And Repair/maint Of Lt Line, Ug Cable Alongwith Connected Works At Unit Located Near To Old Medical Complex Un

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
RC Net work for 3 Kg torque servo motor for voltage stabilizer upto 200 KVA complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Carbon Brush of any capacity for voltage stabilizer upto 200 KVA complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Dismantling existing ACSR conductor of any size/type from PCC/Steel poles including taking down MS works such as cross arms, clamps, hooks, stay etc from overhead line complete all as specified and directed by Engineer-in-Charge.

4.3

-

-

... More
Taking down old unserviceable insulators any type and size from poles including for reuse or removal complete all as specefied and directed all as specified and directed by Engr-in-Charge.

21

-

-

... More
Supply & fixing in replacement lighteneing arrestors expulsion type complete with all fittings, suitable for 11000 Volts grade transmission class, discharge capacity 65KA including brackets, clamps, nuts, washers and connecting to 4mm dia GI earth wire complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply & Fix 11000 volts grade disc type insulator porcelain vitreous 145mm heigh 255mm dia ball and socket type white or brown or green with tension clamps complete all as specified and directed by Engr-in-charge.

9

-

-

... More
Supply & Fix pin type porcelain vitreous white or brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engr-in-charge.

12

-

-

... More
Supply & fix in replacement for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 25 x 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Note: - (i)On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length copper earth strip 25x4 mm.

-

-

-

... More
Supply & fix in replacement for earth continuity conductor or main earthing lead fixed to wall on batton or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation for loop earthing etc as required with 25x3.15mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply and Fixing in replecement LED Decorative Garden/post-top light for 360 degree indirect light IP-65 grade of proterction with High power LED of 20 watt with resistance to impact and corrosion. Glare free and better uniformity.Milky version complete all as specified and directed by Engr-in-charge. Note : Note : Foundation for fixing Garden light/Post top light shall be deemed to be included in the rates quoted by the Contractor complete all as specified & directed by Engr-in-Charge.

15

-

-

... More
Taking down GI strip/ Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed by Engr-in-Charge.

50

-

-

... More
S&F LED indicator lamp for LT/HT panel (Red / Green/Blue/Yellow) complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
S&F ammeter & Voltmeter Selector switch of LT /HT panel complete all as specified and directed by Engr-in-Charge.

13

-

-

... More
M&L for multy function meter input 3 Phase 4 Wire, Voltage Range 300V AC (L-N)/520V AC(P-P), Display Paremeter : Voltage (p-p) (P-L), Amp (R,Y,B) Current : 0-5A , CT 05-6000A insttalled on LT panel including necessory wiring, CT of required size complete all as specified and directed. Make: Multispan Cat Pat No AVF-19N or equvalant in Schneider, L&T complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply ,installation ,testing and commissioning in replacement of feeder pillar board Kiosk type ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design complete Bus Bar chamber comprising incomer MCCB 315 Amp, 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed by Engr-in-Charge.

3

-

-

... More
Supply ,installation ,testing and commissioning in replacement of feeder pillar board Kiosk type ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design complete Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed Engr-in-Charge.

3

-

-

... More
Material and labour for preparation of old painted steel surface by brushing /cleaning strain grease /oily spots with thinner and two coats of spray painting with spray machine to LT panel board ,Bus bar Chamber ,feeder pillar box, load line DB and power factor panel etc including disconnecting of all incoming and out going cables and re connecting after painting. complete all as specified and as directed by Engr-in-Charge.

5

-

-

... More
Supply & Fix in replacement PVC sheathed Twin core Aluminium conductor cable 6 sqmm, complete all as specified and directed by Engr-in-Charge.

300

-

-

... More
Supply & Fix in replacement PVC sheathed Twin core Aluminium conductor cable 10 sqmm, complete all as specified and directed by Engr-in-Charge.

300

-

-

... More
Supply, laying, jointing & testing in replacement of XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 10 Sqmm X 2 core and laid in trenches or passing through pipe or fixed on poles complete all as specified and directed by Engr-in-Charge.

250

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 16 Sqmm X 4 core, complete all as specified and directed by Engr-in-Charge.

200

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 25 Sqmm X 4 core, complete all as specified and directed by Engr-in-Charge.

510

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 35 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

590

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 50 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

650

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 70 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

290

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 95 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

450

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 120 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

450

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 150 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

200

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 185 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 240 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 300 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

150

-

-

... More
Description all as per serial item No 23.00 here-in-before but of size 400 Sqmm X 3.5 core, complete all as specified and directed by Engr-in-Charge.

150

-

-

... More
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed by engineer in charge.

3800

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.

943

-

-

... More
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.

782

-

-

... More
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.

161

-

-

... More
S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed.

543

-

-

... More
S&F double walled corrugated (DWC) pipe of size 90 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed.

730

-

-

... More
S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed.

1684

-

-

... More
M&L for cement concreate 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
M&L for PCC 1:4:8 type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 80 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Dismantling of unserviceable steel tubular pole swaged pole/PCC pole including PCC complete with acessories complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
S&F in replacement erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engr-in-Charge. Note: - (a) Excavation and Earth Work, PCC in foundation shall be measured and paid for separately.

10

-

-

... More
Cleaning the existing exposed surfaces of steel tubular pole of 9.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engr-in-Charge.

200

-

-

... More
Cleaning the existing exposed surfaces of steel tubular pole of 11.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Labour only for re-stretching properly sagged/loose ACSR conductor of any size fixed on LT poles by means of machine method to the permissible limit at different location including tightening of cross arms or D clamps and binding with new binding wire, tightening of jumpers complete all as specified and directed by Engr-in-Charge. Note: - (i) Each line of conductor shall be measured. (ii) Rate including unwinding of old winding wire and rewind with new binding wire after restretching).

500

-

-

... More
S&F in replacement Shackle type porcelain vitreous white, brown or green insulator of size 75 mm height & 90 mm dia including galvanized mild steel straps of size 31 x 3 mm and bolt of size 12 mm dia, washers and nuts of 75 mm height & 90 mm dia for working pressure 1100 volts grade complete all as specefied and directed by Engr-in-charge.

50

-

-

... More
S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator 1100 V grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
M&L for defect rectification of LT 1.1 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pules, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 11 KV / 1.1 KV complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
M & L in replacement for heat shrinkable straight through joint for PVC/XLPE insulated armoured cable of size upto 50Sqmm 3.5/4 core complete all as specified and as directed by Engr-in-Charge.

5

-

-

... More
All as per serial item No: 55.00 above but LT cable size of 70 to 150 Sqmm.

13

-

-

... More
All as per serial item No: 55.00 above but LT cable size of 185 to 240 Sqmm.

5

-

-

... More
M & L in replacement for heat shrinkable End joint for PVC/XLPE insulated armoured cable of size upto 50Sqmm 3.5/4 core complete all as specified and as directed.

5

-

-

... More
All as per serial item No: 58.00 above but LT cable size of 70 to 150 Sqmm

15

-

-

... More
All as per serial item No: 58.00 above but LT cable size of 185 to 300 Sqmm

9

-

-

... More
S&F in replacement Stay assembly complete with acessories as shown in electrical plate no 1 (loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) with 16 mm dia stay rod complete all as specefied and directed by Engr-in-charge including taking down old U/S same items.

3

-

-

... More
S&F in replacement Galvanized steel wire 4 mm dia for continious earth wire on poles and cradles at road crossing with fixing arrangement complete all as specefied and directed by Engr-in-charge.

1

-

-

... More
S&F in replacement on LT overhead line separator 3 way complete all as specefied and directed by Engr-in-charge.

200

-

-

... More
S&F in replacement on LT overhead line separator 4 way complete all as specefied and directed by Engr-in-charge.

200

-

-

... More
M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20x15cm size complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
M&L for repairing the existing LT panel/ Feeder Pilller Box/ APFC Panel any type or size by taking proper shutdown from power house and disconnecting and re-connecting cables connection both in coming and outgoing using appropriate size of thimbles, making proper welding, drilling for smooth functioning of panel / feeder door, replacement of unserviceable aluminium bus bar of suitable capacity/size as per existing including bakelite insulators, terminals, base plate, necessary nuts, bolts & washers, locking arrangement complete all as specified and directed by Engr-in-Charge. Note: - Necessary accessories like MCCB/MCB, CT coil, ammeter, voltmeter, indication lamp, selector switch, Proper Loacking Arrangement, Base Frame etc shall be measured and paid separately as supply & fixing under respective item.

15

-

-

... More
S&F in replacement MCCB four pole 63 Amps,50 Hz with breaking capacity 16KA, Ics = 100% Icu , 415 Volts, Adjustable thermal & Fixed magnetic setting including making all incoming/ outgoing connections complete all as specified and directed by Engineer in Charge.

5

-

-

... More
Description all as per serial item No 67.00 here-in-before but 100 Amps, 3P, with breaking capacity 16 KA, complete all as specified and directed by Engineer in Charge.

8

-

-

... More
Description all as per serial item No 67.00 here-in-before but 125 Amps with breaking capacity 25 KA, complete all as specified and directed by Engineer in Charge.

10

-

-

... More
Description all as per serial item No 67.00 here-in-before but 160 Amps with breaking capacity 36 KA, complete all as specified and directed by Engineer in Charge.

8

-

-

... More
Description all as per serial item No 67.00 here-in-before but 200 Amps with breaking capacity 36 KA, complete all as specified and directed by Engineer in Charge.

7

-

-

... More
Description all as per serial item No 67.00 here-in-before but 250 Amps with breaking capacity 36 KA, complete all as specified and directed by Engineer in Charge.

8

-

-

... More
Description all as per serial item No 67.00 here-in-before but 315 Amps with breaking capacity 36 KA, complete all as specified and directed by Engineer in Charge.

3

-

-

... More
Description all as per serial item No 67.00 here-in-before but 400 Amps with breaking capacity 36 KA, complete all as specified and directed by Engineer in Charge.

2

-

-

... More
S&F in replacement Ampere meter digital type of ratio 0-100 Amp, size 95 Sqmm square type including making incoming/outgoing connections complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
S&F in replacement Voltmeter digital type of ratio 0-415 volt , size 95 Sqmm square type including making incoming/outgoing connections complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
M&L in replacement selector switch rotary type including making connections complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
M&L in replacement Indicator lamp assembly LED type with red/green/blue including making connections complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
M&L in replacement of Current transformer (CT) ratio 100/5 including making connections complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
S&F Onload change over switch FP 200 Amps, 415 Volt, 4 pole complete all as specefied and directed by Engr-in-charge.

1

-

-

... More
S&F Onload change over switch FP 100 Amps, 415 Volt, 4 pole complete all as specefied and directed by Engr-in-charge.

1

-

-

... More
S&F Onload change over switch FP 63 Amps, 415 Volt, 4 pole complete all as specefied and directed by Engr-in-charge.

1

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge.

10

-

-

... More
Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.

-

-

-

... More
S&F in replacement earth continuity conductor on main earthing lead fixed to pole or buried in ground or at any other situation for loop earthing extra as required (beyond 7.5 M) of GI Strip 32 x 6 mm complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 25 x 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.

-

-

-

... More
S&F in replacement earth continuity conductor on main earthing lead fixed to pole or buried in ground or at any other situation for loop earthing extra as required (beyond 7.5 M) of GI Strip 25 x 4 mm complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply & fixing in repair replacement for heat shrinkable Three finger breakout for suitable of PVC/XLPE insulated armoured cable in end of cabel of size upto 50Sqmm 3.5/4 core complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Description all as per serial item No 87.00 here-in-before but LT cable size of 70 to 150 Sqmm.

50

-

-

... More
M&L for switchyard gravelling of 15.0 cm (loose thickness) by broken stone of 40 mm size in and around two pole/ four pole structure/ substation complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Taking out/dismantling any type of LT Panel by disconnecting the electric connection carefully after taking proper shutdown and removing from the site and stacking complete all as specefied and directed by Engr-in-charge.

6

-

-

... More
M&L for ACSR conductor of required size for over head lines on poles including streching,tighting of poles insulator with binding wire of sutable size with insulator/streching of ACSR conductor, including taking down all as specified and diected by Engr in charge.Note: Retrived ACSR Conductor will be deposited at EM store yard with own arrangement by Contractor.

8.25

-

-

... More
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 4x95 sqmm + 1x70 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.

200

-

-

... More
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 4x70sqmm + 1x50 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.

200

-

-

... More
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 4x 50sqmm + 1x35 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.

200

-

-

... More
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 4x35sqmm + 1x25 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.

200

-

-

... More
M&L for Boring for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified by Engr-in-Charge.

20

-

-

... More
Lopping/prooning of tree branches upto the extend to obtain clearance all around the HT/LT over head lines conductor upto 3 mtr from farthest conductor on pole including removing of cut branches & cleaning of site comple all as specified and directed by Engr in charge. Note:- (a) The trees branches etc will be left as it is & will not be carried away by the contractor/DEL as the wood belongs to CEO/DEO & they will be responsiblr to lift the wood. (b) Pruning of all tree branches in one tree shall be measured as one Job. (c ) Contractor will employ sufficient labour to complete the Job with in time as directed. (d) Contractor will be responsible for any type mis-happening/accident while pruning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work & clear it before resuming power supply. However, full assistance will be provided by MES staff. (f) The contractor will provide proper tools & safety to his staff for purning of trees.

300

-

-

... More
M&L for road cuttig existing road for crossing of underground electric cable for laying of any size GI tubing including necessary excavation and earth work including repairing the same as per existing with pre mix bituminious carpet complete all as specefied and as directed by Engr-in-charge. Note: - Width of trench shall be 15 cm and depth shall be upto 30 cm.

30

-

-

... More
Supply, fixing in replacement, testing and commissioning air break isolating switch tripple pole mechanically operated with vertical isolation, 12 insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm dia medium grade GI pipe and locking arrangement of capacity 400 Amps 11 KV with drop out fuse set including making all incoming/outgoing connection of HT cable and ocerhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specefied and directed by Engr-in-charge.Make: Jaipuria/Pactil/ Alstom

5

-

-

... More
Supply only following parts suitable for three phase servo voltage stabilizer upto 100KVA capacity as per existing make or as recommanded by original stabilizer manufacturer complete all as specified and directed by Engr-in-Charge.

-

-

-

... More
(a ) Volt Meter (Digital/Analog)

2

-

-

... More
(b) Ampere meter with CT (Digital/analog)

2

-

-

... More
(c) Micro Processor based control card for each phase

2

-

-

... More
(d) Servo synchronizing motor single phase AC 230 Volts, 3 Kg torque

2

-

-

... More
(e) RC Net work for 3 Kg torque servo motor

2

-

-

... More
(f) Carbon Brush of any capacity

2

-

-

... More
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, IP-65 dust and vermin proof, made of 2 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 40x40x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :-

4

-

-

... More
Incoming : (a) MCCB 100 amps, 4 pole, 25 KA with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 1 Nos. Outgoing : (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 160 Amp, 4 pole, not less than 45 cm long mounted on insulators for incomming supply 01 No. ( b) 15/16 Amp Switch Socket combine - 06 Nos Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) cable glands for incoming and out going suitable cables is including rate quated by vendover. (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables

-

-

-

... More
Opening, maintenance and general servicing of servo voltage stabilizer of capacity 50 KVA and 100 KVA incuding removal of sludge from disserstate coils, buck boost transfomers, tightening of all nuts and bolts, cleaning of stabilzer coils, checking and servicing of servo mechanisam, gear, syncronising system, automatic voltage regulator circuits and other allied electrical components complete all as specefied and directed by Engr-in-charge. Note: a) Voltage stabilizer must be repaired by original manufacturer or by authorised service provider of the company. b) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item c) All T & P and transportaion arrangement are deemed to be included in the rates quoted.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.