Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Eprocure
Opening Date27 May 2024
Closing Date25 Jun 2024
Tender Amount₹ 63,78,600
Costs
EMD
₹ 1,20,680Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Cwek-35/2023-24 Provn Of Accn For Mi Room With Ambulance Garage At Hawas Gulmarg Under Ge 969 Ews
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_615099_5Tender No
CWEK-35/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Section-II (Part-II)
-
-
-
S&F LED Lamp 15 W complete all as specified and directed by Engr-in-Charge
10
-
-
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Section-III brought forward from serial page No. from 34 to 35
1
-
25521.1
Lump sum price worked out by the contractor for ROAD/PATH WORKS as listed in Schedule 'A' Section-IV brought forward from serial page No.36
1
-
29835.08
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule 'A' Section-V brought forward from serial page No. from 37 to 38
1
-
356732.29
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Section-VI (Part-I) brought forward from serial page No. from 39 to 40
1
-
61735.94
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Section-VI (Part-II)
-
-
-
M&L one set LLDPE septic tank any type of soil foundation in PCC 1:2:4 brick work in CM 1:4 RCC slab covers including RCC precast manhole cover having 6MM plate embeded all arround/fiber reinforced cover with angle iron frame vent shaft and sludge chmber etc complete for 30 users complete all as specified and directed by Engr-in-Charge and show drg CESZ-1080/2011.
1
-
-
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4m dia and 3m depth complete all as specified and directed by Engr-in-Charge.
1
-
-
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS listed in Schedule 'A' Section-VII (Part-I) brought forward from serial page No.41
1
-
17313
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS listed in Schedule 'A' Section-VII (Part-II)
-
-
-
Cutting existing GI pipe of 25mm dia in position for inserting tee/specials for branch connection of 25 mm size including GI tee 25x25x25 mm complete all as specified and directed by Engr In Charge.
1
-
-
M&L for cutting of existing road 3.75m and laying of 1:4:8 type D-2 PCC under 80 mm bore NP2 pipe and cover the pipe wit 1:3:6 PCC including packing under hauching against the sides of pipe 1:2:4 not exceeding 25 cm etc complete all as specified and directed by Engr In Charge.
1
-
-
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS listed in Schedule 'A' Section-VIII (Part-I) brought forward from serial page No. from 42 to 45
1
-
550333.24
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS listed in Schedule 'A' Section-VIII (Part-II)
-
-
-
Construction of transformer shed for transformer of capacity upto 300KVA complete all as specified and show on Drg No CESZ/TD-1110/2011 Sheet 1/1 and 2/2 dated 01.12.11
1
-
-
Supply, install, testing and commissioning of LT feeder piller box outdoor type made out of 3.15 mm thick CRCA sheet and MS angle iron frame with weather proof canopy, mounted on PCC pedestal, cubical type, front and rear side openable, compartment type with hinged door ligting lugs 2 Nos, earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc and passivated nut, bolts spring and washers and locking arrangement for each compartment, provision of air vent, dust and vermin proof, provision of cable alley with 400 amps rated aluminium bus bar having 1100 volts grade sleaving and internal connection should be provided with aluminium strips of suitable size and to accommodate and including the following MCCBS duly painted with 2 coats powder coating over a coat of anticorrosive red oxide primer should accommodate the following accessories.
(a) MCCB 4 pole 100 Amps 25 KA (incoming) -01 Nos
(b) MCCB 3 pole 63 Amps 16 KA (outgoing) -02 Nos (c) MCCB 3 pole 40 Amps 16 KA (outgoing) -01 Nos (d) Digital Ammeter with suitable CTs rang and selector switch-1 set
(e) Digital Volt meter 0-500V with selector switch-1 set (f) LED type indication lamps with switches and fuses (R,Y,B) - 1 set
Note: (i) The rate quoted is inclusive of necessary CTs, control wiring and instrument fuse holder.
1
-
-
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, earth plate surrounded by 15 CM thick packed layer of charcoal and common salt alternatively upto 90CM and connected with and including GI strip of size 32x6 mm by means of bolts,nuts,checknuts,and washers 40mm bore GI pipe light grade from earth plate upto testing point for protection of strip and 20mm bore GI pipe medium grade with wire mesh and funnel for watering including necessary excavation and earthwork PCC chamber (1:3:6) type C2 with RCC cover complete all as shown in electrical plate no 3 of MES schedule Part I of SSR Part I(2009) complete all as specified and directed by Engr In Charge.
Notes:(i) RCC pit cover shall be pre cast of RCC(1:2:4) type B 40mm thick reinforcement with 8mm TOR steel @ 100 C/C in leiu of CI cover and the rate includes in the unit rate of item (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate includes in the unit rate of item. (iii) Earth pit chamber and RCC cover shall be painted with red paint over a primer coat and the rate includes in the unit rate.
1
-
-
Lump sum price worked out by the contractor for PROTECTIVE WORKS as listed in Schedule 'A' Section-IX brought forward from serial page No. from 46 to 47
1
-
169000.44
Lump sum price worked out by the contractor for EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS as listed in Schedule 'A' Section-X brought forward from serial page No.48
1
-
142058.36