Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Jan 2024
Closing Date1 Feb 2024
Tender Amount₹ 49,18,000
Costs
EMD
₹ 98,360Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_635208_1Bid Award Id
ViewTender No
CA NO 969 WS - /2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling and taking down the existing LT/HT insulators of any type from any description, complete all as specified and as directed.
108
-
-
Dismantling & Taking out the existing old service cables off sizes, complete all as specified and as directed.
2000
-
-
Dismantling old UNSV existing LT panel with switch gears, complete all as specified and as directed.
3
-
-
Dismantling & Taking out old UNSV earthing, complete all as specified and as directed.
6
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core, complete all as specified and as directed.
90
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core, complete all as specified and as directed.
900
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core, complete all as specified and as directed.
240
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete all as specified and as directed.
150
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 2 core complete all as specified and as directed.
60
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, complete all as specified and as directed.
550
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete all as specified and as directed.
400
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core, complete all as specified and as directed.
380
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete all as specified and as directed.
1700
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core, complete all as specified and as directed.
1355
-
-
S&F in trench/on wall in repairs GI tubing light grade 50mm dia for road crossing and cable protection, complete all as specified and as directed.
24
-
-
S&F in trench/on wall in repairs GI tubing light grade 80mm dia for road crossing and cable protection, complete all as specified and as directed.
30
-
-
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
1
-
-
(a) INCOMING
-
-
-
(i) MCCB 4 Pole 415 volts grade 200 Amps rating and 25 KA rupturing capacity - 01 No
-
-
-
(ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No
-
-
-
(iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No
-
-
-
(iv) CTs ratio 400/5A class ISI marked sets of three each
-
-
-
(v) Indicating lamp-01 set of three
-
-
-
(b) OUTGOING
-
-
-
(i) MCCB 4 Pole, 415 volts grade 200 Amps rating and 25 KA rupturing capacity -01 Nos
-
-
-
(ii) MCCB 4 Pole, 415 volts grade 100 Amps rating and 25 KA rupturing capacity -01 Nos
-
-
-
(iii) MCCB 4 Pole, 415 volts grade 63 Amps rating and 10 KA rupturing capacity -01 Nos
-
-
-
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH front side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
1
-
-
(a) INCOMING
-
-
-
(i) MCCB 4 Pole 415 volts grade 200 Amps rating and 36 KA rupturing capacity - 01 No
-
-
-
(ii) ON Load change over switch 200 amp - 01 No
-
-
-
(iii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No
-
-
-
(iv) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No
-
-
-
(v) CTs ratio 100/5A class ISI marked sets of three each
-
-
-
(vi) Indicating lamp-01 set of three
-
-
-
(b) OUTGOING
-
-
-
(i) MCCB 4 Pole 415 volts grade 125 Amps rating and 25KA rupturing capacity - 01 No
-
-
-
(ii) MCCB 4 Pole 415 volts grade 63 Amps rating and 16KA rupturing capacity - 01 No
-
-
-
(i) MCB DP 10 TO 32 AMP - 14 Nos
-
-
-
(iii) MCB TPN 50 AMP - 01 Nos
-
-
-
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
1
-
-
(a) INCOMING
-
-
-
(i) MCCB 4 Pole 415 volts grade 63 Amps rating and 10 KA rupturing capacity - 01 No
-
-
-
(ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No
-
-
-
(iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No
-
-
-
(iv) CTs ratio 400/5A class ISI marked sets of three each
-
-
-
(v) Indicating lamp-01 set of three
-
-
-
(b) OUTGOING
-
-
-
(i) MCB DP 10 TO 32 AMP - 14 Nos
-
-
-
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH front side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
1
-
-
(a) INCOMING
-
-
-
(i) MCCB 4 Pole 415 volts grade 125 Amps rating and 25 KA rupturing capacity - 01 No
-
-
-
(ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No
-
-
-
(iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No
-
-
-
(iv) CTs ratio 100/5A class ISI marked sets of three each
-
-
-
(v) Indicating lamp-01 set of three
-
-
-
(b) OUTGOING
-
-
-
(i) MCCB 4 Pole 415 volts grade 100 Amps rating and 25 KA rupturing capacity - 01 No
-
-
-
(i) MCB DP 10 TO 32 AMP - 08 Nos
-
-
-
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH Back side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
1
-
-
(a) INCOMING
-
-
-
(i) MCCB 4 Pole 415 volts grade 100 Amps rating and 25 KA rupturing capacity - 01 No
-
-
-
(ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No
-
-
-
(iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No
-
-
-
(iv) CTs ratio 160/5A class ISI marked sets of three each
-
-
-
(v) Indicating lamp-01 set of three
-
-
-
(b) OUTGOING
-
-
-
(i) MCCB 4 Pole 415 volts grade 50 Amps rating and 16 KA rupturing capacity - 01 No
-
-
-
(ii) MCB DP 10 TO 32 AMP - 15 Nos
-
-
-
(iii) MCB DP 40 to 63 AMP - 02 Nos
-
-
-
(iv) MCB TPN 32 AMP - 03 Nos
-
-
-
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Adm Block) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
1
-
-
(a) INCOMING
-
-
-
(i) MCCB 4 Pole 415 volts grade 40 Amps rating and 16 KA rupturing capacity - 01 No
-
-
-
(ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No
-
-
-
(iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No
-
-
-
(iv) CTs ratio 160/5A class ISI marked sets of three each
-
-
-
(v) Indicating lamp-01 set of three
-
-
-
(b) OUTGOING
-
-
-
(i) MCB DP 10 TO 32 AMP - 10 Nos
-
-
-
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
1
-
-
(a) INCOMING
-
-
-
(i) MCCB 4 Pole 415 volts grade 125 Amps rating and 25 KA rupturing capacity - 01 No
-
-
-
(ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No
-
-
-
(iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No
-
-
-
(iv) CTs ratio 400/5A class ISI marked sets of three each
-
-
-
(v) Indicating lamp-01 set of three
-
-
-
(b) OUTGOING
-
-
-
(i) MCB DP 10 TO 32 AMP - 11 Nos
-
-
-
(ii) MCB DP 40 to 63 - 02 Nos
-
-
-
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
1
-
-
(a) INCOMING
-
-
-
(i) MCCB 4 Pole 415 volts grade 100 Amps rating and 25 KA rupturing capacity - 01 No
-
-
-
(ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No
-
-
-
(iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No
-
-
-
(iv) CTs ratio 100/5A class ISI marked sets of three each
-
-
-
(v) Indicating lamp-01 set of three
-
-
-
(b) OUTGOING
-
-
-
(i) MCB DP 10 TO 32 AMP - 10 Nos
-
-
-
(i) MCB DP 40 TO 63 AMP - 02 Nos
-
-
-
Earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick buried directly in to the ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth strip 32 x 6 mm by means of bolts, nuts thimble check nuts and washers of galvanised iron or steel using GI including PCC (concrete chamber) 1:3:6 Type C-1 using 20 mm graded stone aggregate with fair finish of internal surface concrete, 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68 mm) 8 mesh per inner inch, 80mm thick RCC Pit cover 320mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM and charcole dust and common salt all as shown in electrical plate No-3 MES SSR Part-I and specified including provision of earth wire/ strip protected by 40 mm dia medium grade GI pipe including all excavation and earth work & connecting the earth earthing to an earthing test point/ transformer neutral/ body LT panel etc and testing on complete, complete all as specified and as directed Note :- Quoted rate of earthing shall be deemed to included cost of 7.5 M long galvanised iron strip 32X6 mm and protection pipe of 40mm bore medium grade, GI light grade 20mm bore watering pipe.
10
-
-
Supply and fixing RCC cable route marker for LT complete all as specified and as directed
110
-
-
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth,for foundations,laying of pipes etc not exceeding 10sqm on plan for mamholes etc and not exceeding 1.5 metre in depth and getting out in Soft/loose soil, complete all as specified and as directed.
795
-
-
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm.in hard/dense soil.
332
-
-
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed.
463
-
-
Supply and laying of burnt clay building bricks, sub-class 'B' (old size) Designnation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and as directed.
23.12
-
-
M&L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1 Note:-Sand shall be fine sand as specified for plastering.
234
-
-
Junction box of size 300x300x250 mm made of MS Sheet 1.6 mm thick, front door openable with fixing screw painting with two coats of synthetic enamel power coated paint over a coat or red oxide including alumn bus bar 4 Nos of size 25x3mm mounted on epoxy based post insulators and drilled holes for connection including 01 Nos MCB SPN 6 Amps , 2 Nos MCBs 06 amps incl magnetic lock system all as required and fixed to poles using MS strip of size 32x6mm and nuts & bolts of required size all as required at site or directed by Engr-in-charges.
8
-
-
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
111
-
-
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
18
-
-
S&F ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with squirrel cage induction motor.
109
-
-
Supply and install wall mounted split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating 1.5 TR Hot and Cold capacity.
6
-
-
S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and capacity % KVA.
4
-
-
Note:- Schedule of credit Rs. 32,161.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
-
-
-