Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date31 Aug 2024
Closing Date12 Oct 2024
Tender Amount₹ 45,71,021
Costs
EMD
₹ 91,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669352_1Bid Award Id
ViewTender No
CA NO- GE(N)/AKH-35/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @200ml/bag of cement and curved before laying of membarance.
(c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. Note:-(i) The water proofing treatment shall be got carried out from the authorised personal of the Company all as specified and directed.
(ii) For non-accessible roofs : Top surfaces of roof after carrying out treatment as specified here-in-above shall be provided with 2 coats of aluminium paint over a coat of primer as per manufacturer’s instructions.
704
-
-
PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in roof kerb, padding , finished surface even and fair, complete all as specified and directed.
7
-
-
Disconnecting existing tanks of capacity 250 to 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including necessary replacement of tanks joints of any size & description, complete all as specified and directed.
4
-
-
PVC (SWR) pipes 75mm dia any length single socketed with rubber ring joint laid in trenches/floors, complete all as specified and directed.
3
-
-
Applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall surface, complete all as specified and directed.
Note:-
(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/
(ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same.
24
-
-
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in any type of soil, complete all as specified and directed.
198.17
-
-
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed.
155.21
-
-
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed
42.96
-
-
Construction of valve pit of sizes 90cmx90cmx90cm (internal dimentions), any type soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, 100mm thick PCC in foundation of the mix (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) brick masonry in cement mortar (1:4), rendering, 12 mm thick cement mortar (1:4) internally, finished even and fair & pointing flush externaly as the work proceeds in the same mortar, mild steel frame 40x40x5mm, MS sheet cover 3.15mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC1:2:4 type B-1 coping with two coats of black bituminous paint, complete all as specified.
3
-
-
Taking down old unsv sluice valve and Supply and fixing ball valve size 150mm having SS ball with both CI end flanged, ISI marked, with nuts, bolts and washers and rubber gaskets with stainless steel handle over PVC coating complete all as specified and directed.
6
-
-
Taking down old unsv gun metal glove or gate valve of 50mm bore and supply and fixing with iron wheel head screwed bith end for iron pipe, complete all as specified and as directed.
25
-
-
Taking down old unsv gun metal glove or gate valve of 20mm bore and supply and fixing with iron wheel head screwed bith end for iron pipe, complete all as specified and as directed.
35
-
-
Taking down old unsv gun metal glove or gate valve of 15mm bore and supply and fixing with iron wheel head screwed bith end for iron pipe, complete all as specified and as directed.
30
-
-
Taking down and supply and fixing GI water tubing 150 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches, complete all as specified and as directed.
400
-
-
Taking down and supply and fixing GI water tubing 50mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches, complete all as specified and as directed.
500
-
-
Taking down and supply and fixing GI water tubing 20mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches, complete all as specified and as directed.
600
-
-
Taking down and supply and fixing GI water tubing 15mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches, complete all as specified and as directed.
250
-
-
Plain Cement Concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of electric poles/struts etc including necessary form work and fair finish to exposed surfaces without using extra cement, complete all as specified and directed.
21
-
-
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
384
-
-
Sub main wiring in replacement complete with
2 run of 4 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLSH type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour code and applying putty including cutting and chiseling and complete all as specified and directed.
Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as RM.
198
-
-
Sub main wiring in replacement complete with
2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLSH type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour code and applying putty including cutting and chiseling and complete all as specified and directed.
Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as RM.
90
-
-
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC casing capping 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are surface in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Make of Cables Havells, KEI, Grandlay
-
-
-
(Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
-
-
-
Description All as per item No-25 here-in-before but for One light point/fan controlled by one switch.
190
-
-
Description All as per item No-25 here-in-before but for one ceiling fan switch
35
-
-
Description All as per item No-25 here-in-before but for one bell point
7
-
-
Description All as per item No-25 here-in-before but for one exhaust fan switch
5
-
-
Description All as per item No-25 here-in-before but for One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
65
-
-
Description All as per item No-25 here-in-before but for One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
36
-
-
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers are to be used of same make/brand only and shall be deemed in to included in quoted rate only.) for One 15 amps power socket outlet point controlled by one 16 amps switch on independent board.
46
-
-
Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed.
198
-
-
Modular type switch 6 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and directed.
“Cat part No ACVSXXWO61 of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved”.
331
-
-
Modular type switch 16 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and directed.
“Cat part No ACVSXXW161of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved”.
46
-
-
Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed. “Cat part No ACVKSWW063 of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved”.
101
-
-
Modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked Complete all as specified and directed . “Cat part No ACVKCWW163 of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved”.
46
-
-
Fan regulator modular type electronic compatible with BLDC fan, stepped type 100 Watts, 2 module 240Volts, AC ISI marked complete all as specified and directed. “Cat part No ACVRFHW008 of Crabtree (Havells) or its Equivalent cat part of make as specified in list of make here- in after.
35
-
-
Electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed.
7
-
-
Modular Bell push 6A 1 module, 240V, ISI Marked Complete all as specified and directed.
“Cat part No ACVSBXW061 of Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Seimens as approved by GE”.
7
-
-
LED Bulb 12 watt, 240 volts, 50 HZ, pin type including removing old unsv items, fixed in repairs complete all as specified and as directed. Make- Cat part No BL0212WB22 of BENLO or its equivalent of Make-Bajaj, Havells, Crompton as approved.
32
-
-
LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz, Complete all as specified.
Cat part No LW07-141-XXX-57 G1 Make Wipro or equivalent in Phillips, Crompton, Havells, bajaj as approved.
12
-
-
LED light fitting 1x10W, 220V, for mirror AC decorative type with diver, high out put diffuser 2 feet , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
5
-
-
LED batten with polycarbonate housing & interrated electronic driver lights fitting 1 x 20W, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, all as specified and directed. Make Cat Part No- LUMILINENEOBS20WLED840SPCWH of Havells or equivalent in Bajaj, Wipro, Benlo
105
-
-
LED secruity light fitting of capacity 25 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and testing and including removing of old unserviceable item complete all as specified and directed. Make-Havells Cat Part No-ENXTP25L WH PO PC SD of Bajaj or its equivalent in Havells or Wipro as approved.
8
-
-
Exhaust fan single phase metal body, AC 230 Volt, 50 Hz, 900 RPM of size 300mm sweep with louvers shutter complete with all accessories including connecting up from ceiling rose complete all as specified and directed. Make:- Cat part No:- Turbo Force 1P Grey of Havells or its Equivalent cat part of make-BAJAJ,CROMPTON GREAVES, GEC, KHAITAN,ORIENT as approved by GE
5
-
-
Ceiling fans complete with blades, down rods, and accessories, 230 volt, 1200mm sweep, min air delivery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make:- Cat Part No Zinger of Make Havells or its Equivalent cat part of make as specified in list of make here- in after.
Note : Items declared BER vide convening order No 4000/CO/BPs/465/E4 dated 21 May 2022 already deposited with MES/ E&M yard.
35
-
-
LED INVERTER batten 18w/20w decorative box type light fitting,charging time 10 hour,emergency backup time 4 hours,Driver efficiency /= 85% energy efficiency,0.95 PF, inbuilt dry battery & driver,pre-wired,rated voltage 230Volts,50Hz and including providing PVC/Wooden solid round/square block -02 Nos and connecting up with twin core twisted copper wire from LED fitting to ceiling rose and removing old unserviceable fitting complete all as specified and directed. Make :- Halonix cat No. HLB-08-20-CW-INV or its equivalent in Bajaj, Surya as approved.
28
-
-
Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 4 way suitable for flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 100Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat all as specified and as directed. Make:- Legrand cat No. 5076 21 8 way / Hager Cat Part No.VYS04G / L&T Cat Part No-DBSPN004GD as approved
2
-
-
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified. Make:- Havells cat part No-DHDPSHODPW08 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
14
-
-
MCB's single pole & neutral 240 volts 40 to 63Amps 10 KA 'C' series, all as specified and as directed.
Make: Havells Cat Part No.DHMGCSNF040-063 or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE
14
-
-
MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series fixed complete all as specified. Make:-Havells cat part No-DHMGCSPF006-032 or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE
84
-
-
Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
2
-
-
Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed. Make Havells(Monza EC),or equivalent cat part of make as specified in list of make here-in-after.
5
-
-
Single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB of capacity 20 amp 240 volts and connecting electrically including taking down unserviceable enclosure with U/S MCB complete all as specified and directed.
16
-
-
Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
70
-
-
Supply and fixing of Double wall corrugated (DWC) HDPE tubing 50 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate.
(b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc.
(c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates
66
-
-
Construction of a building for guard room with attached toilet and bathroom complete all as specified and shown in the list of drawings.
1
-
-
Surface excavation n exc 30cm deep and averaging 15 cm any type of soil, complete all as specified and directed.
75
-
-
Hard core of broken stone/boulders of gauge n exc 63mm deposited spreed and leveled in layers n exc 15cm thick watered and rammed to a true surface, complete all as specified.
7.5
-
-
100mm thick Plain Cement concrete Type D-2, 1:4:8 (using 40mm graded crushed aggregate) as in sub-base of floors, path/hardstandings etc, finished even and rough to receive topping layer complete all as specified.
75
-
-
25mm thick sand cushion in flooring below interlocking tiles complete all as specified and directed.
2
-
-
Supply and fixing 80 mm thick M-40 Grade Machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006, jointed and pointed with grey cement and no pigment including 50mm thick sand cushioning and PCC lock at edges, complete all as specified and directed.
75
-
-
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and directed.
7.5
-
-
Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregateof 150 mm dia concrete bed to drain pipe incl packing under, and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
27
-
-
Reinforced concrete pipes150mm dia, class NP3, laid and jointed complete with collars all as specified and directed.
25
-
-
Soakage well of size 1.2 M dia X 3.00M deep including excavation in any type of soil, foundation in pcc 1:3:6, well of honey combed built in brick work in CM 1:4. and RCC cover M-25 concrete, filling with brick bats, complete all as specified & shown on Drg No CE/TD-1202/03 sheet 1/2 & 2/2.
1
-
-
Construction of Septic tank with cover slab 10 users capacity with inlet chamber, with brick work in CM 1:4, M-25 (design mix) concrete in cover slab , internal plaster 20mm thick in CM 1:3 using WPC including necessary excavation and earth work in any type of soil, RCC precast manholes covers with angle iron welded frame, CI vent pipe 100mm dia with cowl complete all as specified and shown on Drg No CE/TD-1202/03 sheet 1/2 & 2/2.
1
-
-
Supply, laying in replacement, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
85
-
-
Protection to cable with one layer of brick laid flat across the cable using all size sub class 'B' Bricks all as specified and directed.
0.67
-
-
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
6.07
-
-
S&F in repair GI water tubing in replacement 25mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed.
70
-
-
Cutting of existing GI Pipe for installation Tee 50mm, Nipple of reqd size and connected items all as specified and directed.
1
-
-
25 mm bore Gun-metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed high pressure with crutch or butterfly handle fixed in repairs complete all as specified and as directed.
1
-
-
Soil Investigation bore holes/open trial pits for STP/DCPT as per Indian standard in ordinary soil cosisting clay/silt/garvally strata upon maximum depth of 6.0 or refusal whichever is earlier and including the follwing tests to be carried out as per IS.
(i) Moisture contant
(ii) Specific gravity test
(iii) Atterberg limit test
(iv) Plastic limit test/liquid limit test (v) Proctor compaction test
(vi) Shirinkage limit test
viii) Triaxal compression test on chhesivness soil
vii) Direct shear test
(ix) Unconfined compression test
(x) Field tensity test
(xi) Hydrometr analysis
(xii) Particle size determination
(xiii) Vane test (field test)
(xiv) Sounding test (pile test)
and prepare SBC report and submission of detailed soil investigation report in triplicate
1
-
-
Evaluation Notes How It Works ?