Himachal Pradesh Irrigation And Public Health Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Pipes and Pipe Related Activities
Eprocure
Opening Date10 Sep 2021
Closing Date17 Sep 2021
Tender Amount₹ 63,50,958 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Improvement Of Lwss Shilru Bhawana In G.p. Dhamoon Under Jal Shakti Section Jubberhatti Tehsil Distt Shimla Hp (sh C/o Head Weir, Retaining Wall, Filter Media Andother Repair Work, Storage Tank 40000 Ltrs Cap For Shilli Kalimu,laying And Jointing

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying cement concrete 1:3:6 (1cement:3sand:6graded stone agg. 40 mm nominal size)and curing complete excluding cost of form work i/c all leads and lifts and to the entire satisfaction of the Engineer-in-charge in :-a) Foundation and plinth.

4.6

-

-

... More
Providing and laying cement concrete 1:4:8 (1cement:4sand:8graded stone agg. 40 mm nominal size)and curing complete excluding cost of form work i/c all leads and lifts and to the entire satisfaction of the Engineer-in-charge in :-a) Foundation and plinth.

31.8

-

-

... More
Providing and laying cement concrete 1:6:12 (1cement:6sand:12graded stone agg.40mm nominal size) and curing complete excluding cost of form work including all leads and lifts. :- a) Foundation and plinth.

3.52

-

-

... More
Providing and laying cement concrete 1:5:10(1cement:5sand:10 graded stone agg. 40mm nominal size)with 15% plum concrete and curing complete excluding cost of form work in retaining wall/breast wall,the size of plums shall usually be 150mm to 300mm.as per HPPWD specifications within all leads and as per the direction of the Engineer-in-charge.

102.98

-

-

... More
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering, strutting , strutting and propping etc. with wooden, battens, and ballies, height of propping and centring below supporting floor to ceiling not exceeding 3 mtrs.and removal of the same for insitu reinforced concrete and plain concrete work in complete in all respect in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.

-

-

-

... More
Vertical surfaces such as circular walls (any thickness) ,partitions and the like including attached pillasters,buttresses, plinth and string courses and the like.

410.67

-

-

... More
Flat surfaces such as soffits of suspended floors,roofs, landings, and the like:-i)Floors etc. upto 200mm in thickness.

63.93

-

-

... More
Stone filling behind the retaining walls complete in all respect.

20.25

-

-

... More
Cement concrete flooring 1:2:4(1cement:2sand:4graded stone agg.20mm nominal size) laid in one layer finished with a floating coat of neat cement i/c all leads and lifts and as per direction of Engineer-in-charge.:-

-

-

-

... More
a)40mm thick.

66

-

-

... More
Providing and placing in horizontal layer filtering media duly graded ,screened, washed and cleaned as specified by the Engineer-in-charge. i/c all leads and lifts.

-

-

-

... More
Top layer:- Fine sand (Eff.size 0.20mm to 0.40mm and uniformity-co- efficient 2.00 to 3.00).

13.67

-

-

... More
Second layer:- Coarse sand 3mm to 6mm.

2.73

-

-

... More
Third layer:- Bajri 6mm to 20mm.

0.91

-

-

... More
Fourth layer:- Bajri 20mm to 25mm.

1.82

-

-

... More
Bottom layer:- Broken stone 50mm to 75mm size.

2.73

-

-

... More
Repair to plaster in patches of 2.50 sq.m. and under and 10 to 15mm thick including cutting the patch in proper shape and replastering the surface of the wall including disposal of rubbish to the dumping ground within a lead of 20 metres with:-Cement Mortar 1:3(1cement:3sand).

81

-

-

... More
Providing and fixing on wall face PVC (D-plast) rain water pipes of working pressure not less than 4.5 kg/sqm. Including filling the joints with approved adhesive complete in all respect as per the direction of the Engineer-in-charge.

-

-

-

... More
75mm dia pipes.

20

-

-

... More
Distempering two coats with oil bound washable distemper of approved brand and manufacture of and of required shade of undecorated wall surface to give an even shade over and i/c a priming coat with Alkali resistance primer of approved brand and manufacture after thoroughly brushing the surface free from mortor dropping and other foreign matter and also i/c preparing the surface even and sand papered smooth.

81

-

-

... More
Extra for every subsequent coat of distempering with oil bound washable distemper of approved brand and manufacture.(one coat).

81

-

-

... More
1.80 mtrs. High fencing with steel post of built up section 2.50 metre centre to centre with nine horizontal lines and two diagonals of galvanised steel barbed wire (IS: 278-1962 type.I) weighing 9.38 kg/ per 100 metre (minimum)strained and fixed to posts with G.I staples, including coal tarring of ballies complete) cost of post, struts and straining bolts shall be paid for separately).

50

-

-

... More
Providing and laying heavy duty precast cement concrete inter locking paver blocks vibro compacted upto M-50 grade incuding border or kurb block grey or coloured over sub-base of concrete with 25mm thick average thickness of cement mortar 1:4(1cement:4sand) laid over and jointed with neat cement slurry mixed with pigment to maltch the shade of blocks including curng rubbing and polishing complete (sub-base concrete floor to be paid for separately) 40mm thick block.

236

-

-

... More
Providing and laying cement concrete work 1:11/2: 3(1cement:11/2sand:3 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge.

-

-

-

... More
In foundation and plinth.

26.41

-

-

... More
Walls (any thickness) but not less than 0.1m thickness) attached pillasters, buttresses, plinth and string courses etc. from top of foundation level upto floor two level.

30.19

-

-

... More
Suspended floors, roofs, landings,shelves and their supports balconies, beams, girders, bressumers and cantilevers upto floor two level as per direction of Engineer-in-charge.

1.87

-

-

... More
Providing Mild steel/Tor steel reinforced for RCC work including bending, binding and placing in position complete upto floor two level within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge. a) Tor steel.

5717.7

-

-

... More
White washing with lime on undecorated wall surfaces two coats to give an even shade including thoroughly brooming the surface to remove all dirt, dust , mortar dirt and other foreign matter as per the direction of Engineer-in-charge including all leads and lifts.

124.13

-

-

... More
Providing and fixing precast concrete manhole cover & frame conforming to IS:12593-1988 Part.I and IS-12592-1991 Part.II, 500mm diameter, medium duty.

1

-

-

... More
Providing in RCC work smooth finishing of the exposed surfaces with cement mortar 1:3 (1cement:3sand).

124.13

-

-

... More
Steel work welded in built up sections, trusses and framed work including cutting hoisting, fixing in position and applying a priming coat of red lead paint with in all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge.

-

-

-

... More
In gratings framed guard bars, ladders, railings, brackets and similar works.

32.4

-

-

... More
Wiring for light point/fan point/exhaust fan point/call bell point wire 1.5 sqm. PVC.insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible)copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5sq.mm.HRFRLS/PVC insulated single core copper conductor cable as required. complete in all respect i/c all leads and lifts.. Group C.

15

-

-

... More
Wiring for circuit/submain with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible)copper conductor cable in surface/recessed PVC conduit along with 1No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required complete in all respect i/c all leads and lifts. .

-

-

-

... More
2x10 sq.mm.

10

-

-

... More
Supplying and erection of 6 amps to 32 amps. Rating 10 KVA breaking capacity 240 volts."C" curves miniature circuit breaker of following poles in the existing MCB DB complete with connections etc.as required complete in all respect i/c all leads and lifts.

-

-

-

... More
Single Pole. Category.A.

6

-

-

... More
Single pole and neutral Cat.A.

1

-

-

... More
Supply and errection of 40/50/63 amps. Rating 10 KA breaking capacity, 240 volts, 'C' curves miniature circuit breaker of following poles in the existing MCB DB complete with connection etc. as required complete in all respect i/c all leads and lifts.

1

-

-

... More
Supply / fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recess complete with tinned copper bushes, neutral link, earth bar, din bar, detachable gland plate,interconnection including painting, earthing etc. as required complete in all respect i/c all leads and lifts.

-

-

-

... More
Double door-4 Way.

1

-

-

... More
Double door-12 Way.

1

-

-

... More
Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snap-on installers, suitable for 28 watt FTL (T5), complete with all accessories (including one No.T-5 Tube).connections, testing and commissioning etc. as required.complete in all respect i/c all leads and lifts.

-

-

-

... More
1x28 watt-FTL(T5) (Category-A).

4

-

-

... More
Supplying and fixing of following sizes of steel conduit alongwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20mm dia.

20

-

-

... More
25mm dia.

30

-

-

... More
Supplying and drawing following size of PVC insulatled, heat resistant, flame retgardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed, steel/PVC conduit as required.

-

-

-

... More
PVC insulated HRFR LS Copper conductor 1.5 Sq.mm. 3X1.5 Sq.mm.

20

-

-

... More
PVC insulated HRFR LS Copper conductor 4.0 Sq.mm. 3x4.0 Sq.mm.

30

-

-

... More
Supplying and fixing metal box of 180mmx 100mmx 60mm deep nominal size) on surface/ recess with suitable size of phenolic laminated sheet in the front including, prov.and fixing 6 pin 15/16 amps.socket outlet and 15/16amps, piano type switch , connections, painting etc. as reqd.

4

-

-

... More
Supplying and fixing metal box of 100mmx 100mmx 60mm deep nominal size) on surface/ recess with suitable size of phenolic laminated sheet in the front including, prov.and fixing 5 pin 5/6 amps. socket outlet and 5/6amps, piano type switch , connections, painting etc. as reqd.

4

-

-

... More
Supplying and fixing bakelite batten/angle holder including connecitons etc. as required.

2

-

-

... More
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes,complete with all accessories but excluding CFL lamp including making connections, testing etc. as required.

-

-

-

... More
Fixed type wall bracket 150 dia, single lamp (Catgegory-A).

4

-

-

... More
Supplying and fixing of bulk head fitting of all sizes and shapes,connecting one no thread type CFL lamp holder complete with all accessories, but excluding CFL lamp including making connection/testing etc.as required.

-

-

-

... More
Bulk head fitting, CFL type (Category-A).

4

-

-

... More
Prov. and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages. Connections, testing and commissioning etc.as required.

-

-

-

... More
Exhaust fan Heavy duty, 300mm sweep.

1

-

-

... More
Earthing with copper earth platle 600mmx 600mmx 3mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.

1

-

-

... More
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.

1

-

-

... More
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc.as required.

5

-

-

... More
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size with permissible variation in size of plus minus 5mm,welded frame work of M.S.angle iron 50mmx 50mmx 6mm thick duly welded complete with 3mm thick M.S.sheet fixed with hinges as open able front.complete with locking arrangement including painting and bonding to the existing earth as required.

0.5

-

-

... More
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoujred/XLPE power cable working voltage 1100 volts grade direct in ground to be laid 1 meter below the ground level including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering:- a)Armoured cable 6sq.mm (twin core).

50

-

-

... More
Supplying and errection of galvanized iron (G.I) pipe pole "A" quality of suitable length and dia 4.47 mm thickness, including fixing upto a given depth below G/L. The hole of excavation about 30-cm dia and given depth to be filled in upto 15cm below G/L with 1:3:6 cement concrete and there above plinth with 1:2:4 cement concrete upto a height of 45 cm from G/L. The radial thickness of the plinth above G/L should not be less than 6.35cm and sufficient to completely flush a 180mmx 100mmx 45mm deep. glass filled Nylan F.R. grade box for housing a 16 amp. MCB the outer surface of the plinth to be finished with 1:3 cement plaster 6mm thick, the fuse-box shall have a water tight cover, including painting of pole with two coats of approved colour, brand and manufacture of paint over as priming coat complete in all respects as required:-

-

-

-

... More
4 meter long having nominal bore dia 65mm dia planting depth 80cm with pit depth 95 cm.

2

-

-

... More
Providing and fixing street light fixture with cast al. body deep drawn reflector, toughned glass (IP66)LH open construction ballast capacitor and ignitor complete with 250 watt sodium lamp twinkle or equivalent make Cat No.TSL-796 complete with GI bracket, money protection and all accessories,connections, testing and commissioning etc. as required.

2

-

-

... More
Supplying and fixing weather proof IP-65 MCB box on existing pole for connection to pole light & further connection to next light (Hensel or equivalent make).

2

-

-

... More
Laying and jointing in trenches,galvanised mild steel tubes(Light grade) i/c tube fittings such as Tee, elbow, union & nipple.(earth work in trenches to be measured and paid for separately)i/c all leads and lifts complete in all respect. Labour rate only.

-

-

-

... More
65mm dia nominal bore.

300

-

-

... More
32mm dia nominal bore.

100

-

-

... More
25mm dia nominal bore.

2050

-

-

... More
20mm dia nominal bore.

1250

-

-

... More
Providing and fixing brass full way valve with wheel of superior quality including all leads and lifts.

-

-

-

... More
65mm dia nominal bore.

3

-

-

... More
32mm dia nominal bore.

6

-

-

... More
25mm dia nominal bore.

10

-

-

... More
20mm dia nominal bore.

10

-

-

... More
Providing and fixing of G.I.Tee of superior quality ISI marked complete in all respect.

-

-

-

... More
20mm dia.

5

-

-

... More
25mm dia.

5

-

-

... More
32mm dia.

5

-

-

... More
Providing and fixing G.I.Union of following dia complete in all respect.

-

-

-

... More
20mm dia.

10

-

-

... More
25mm dia.

10

-

-

... More
32mm dia.

10

-

-

... More
Providing and fixing G.I.Nipple 50mm long of different diameter complete in all respect i/c all leads and lifts.

-

-

-

... More
20mm dia.

5

-

-

... More
25mm dia.

5

-

-

... More
Providing, laying & commissioning at site in trenches to be beveled ended pipe conforming to IS/ISO:3183-2007 (Latest with up to date ammendments) having minimum wall thickness as specified below & capable of withstanding required test pressure as prescribed in IS/ISO code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be levelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest applicable and with uptodate ammendments (leak proof) in three layers at site of work with welded rods of Advani/oeriliken make/ISI marked (welded rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail pieces,tee bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions. and cutting of pipes wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-In-Charge. The pipe shall have zinc coating inside & outside confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API L 210. The laying shall confirm to BIS 5822-970 or latest with upto date ammendments to the entire satisfaction of Engineer-In-Charge. (Earth work & cost of MS Flanges after 100meter length shall be measured & paid for seperately.) including all leads, lifts and carriage of materials at site and as per direction and to the entire satisfaction of the Engineer-In-Charge.

-

-

-

... More
R.D 0 to 800 65mm dia with 4.80mm wall thickness.

800

-

-

... More
Laying and jointing in trenches galvanised mild steel tube 65mm dia (Heavy /Medium grade) of following diameters conforming to IS-1239 as specified below jointed with butt welding according to relevant BIS code 816-1969 including all short pieces bends,tee and other specials etc. made from parent tubes as applicable for the particular reach and of approved specifications as per site conditions including flushing, cleaning and hydraulic testing complete to the best satisfaction of the Engineer-in-charge. The laying of pipes should conform to BIS code 5822-1970 within all leads and lifts complete in all respect.

-

-

-

... More
R.D.800 to 1000. 65mm dia (Heavy grade).

200

-

-

... More
R.D 1000 to 1250 65mm dia (Medium grade)

250

-

-

... More
Providing fixing and jointing of M.S.flanges conforming to IS-6392-1971 (latest with upto date ammendment) flange dia 65mm, table and nominal pressure as specified below welded at both ends of pipes (as per site condition for particular reach as required) according to relevant BIS Code 816-1962 and provided with nuts and bolts of required size as per BIS code 1364 including 3mm thick compressed asbestos fiber gasket of synthetic rubber gasket conforming to relevant BIS code 2712-1965 complete in all respect including all leads and lifts.

-

-

-

... More
Flange table-28.

8

-

-

... More
Flange table-17.

2

-

-

... More
Flange table-5.

3

-

-

... More
Dismantling of old R/Main 40mm dia with electric welding complete in all respect and stacking properly at nearest JSV Store.

1150

-

-

... More
Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single, /Multistages centrifugal pumps or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB/ Becon weir/Kirloskar/ BE/Jyoti or any other make approved from Jal Shakti Vibhag as per BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to suitable for lifting Raw water for under mentioned characteristics with bronze impellers/ priming funnels casing ring and shaft sleaves or bronze shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on a common C.I./Cast steel base platel (base plate to be from the manufacturers of the pumping unit only) to slip ring/squirrel cage screen protected drip proof induction motor of standard make such as Kirloskar/Crompton/Bhel/NGEF/GEC/ Siemen/Jyoti/ABB or any other make approved from Jal Shakti Vibhag suitable for operation on 415(+) /-5% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-)25% of the duty point head. The motor should be as per IS:325-1978 with upto date ammendments read with IS:900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- 2x40HP=80HP.

-

-

-

... More
(I) Discharge (Q) 3.05 LPS per set.(ii) Total Dynamic Head:- 455.87 Meters.(a) LWL in sump well(h) :- 1000.00 Meters.(b) Shaft level :- 1000.00 Meters.© Level at discharge point : 1417.00 Meters.(d) Suction lift :-(+tive) Meters.(e) Residual head:- 3.00 Meters.(f)Static head:- 417.00 Meters.(iii) Rising main(a) Length. 1250.00 Meters.(b)Dia :- 65mm.(iv) Pumping hours. 8 hours.(v) Altitude of Installation above MSL - Meters.(vi) Characteristics of water(a) Temperature oC(b)Abient Temperature oC© Turbidity Clear water (d) Alkalanity: Mg/CA CO3. e) Size of the solids.....mm (f) Others:- Pumps Specifications: i)Make:- . (ii) Model :- (iii) No.of stages :- .(iv)Material manufactures certificate to be appended (I) Head(H):- mtrs. (ii)Discharge(Q lps.(iii)BHP absorbed (iv)Efficiency(n):- . (v) NPSH(K)

2

-

-

... More
(b) Motors Specification:- I) Make:- .ii) Model:- iii) Motor rating (KW ):- .iv) Speed.:-

2

-

-

... More
© Coupling]

2

-

-

... More
(d)Base Plate ] .

2

-

-

... More
Supply of suitable direct on line/oil immersed star delta /ATS/Stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/ Larson and Turbo conforming to BIS-8544-1979 latest with upto date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type overload release & dash pot, time lag,under voltage release with initial oil filling.

2

-

-

... More
Note:-Star delta starter upto 37.5 KW,ATS between 37.5 KW to 50 KW and starter rotor starter with slipring motor beyond 50 KW.

-

-

-

... More
Providing MS .sheet,16 SWG steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, comprising and capable of mounting the following accessories with all internal connections: The drawing of panel board shall be subject to approval of Engineer-in-charge.

1

-

-

... More
Ammeter AC supply 100mm dia circular dial Auto electrical AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS:1248(P-II) 1983 with upto date ammendments.

2

-

-

... More
Voltmeter A.C. Supply 100mm dia circular dia Auto electric/AE/IMP/Havells make of suitable range with selector switches as per IS:4064-1978 with upto date ammendments.

2

-

-

... More
ICTP switches with HRC fuses of Kilburn/L&T/Siemens/Standard/Havells make and having Capacity 30% extra of the operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTP SWITCHES: I) Type : ii)Make:- iii)Capacity Amp.

2

-

-

... More
Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and one copper bar of half the rating of full length for neutral phase as per BIS:8084-1976 and 11353-1985 read with 5578-1985 with upto date ammendments. BUS BAR CHAMBER:- i)Type: - . ii)Make:- iii)Rating

2

-

-

... More
ACB/M.C.B/Oil Circuit Breaker of suitable capacity of Kilburn/ L&T/ MEI/GEC/Standard make on incoming feeder for motor offered by the tenderer conforming to BIS-2516-1985 latest with upto date ammendments with initial oil filling whenever required and neutral linked under voltage release.

2

-

-

... More
Three phase Indicating lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments. THREE PHASE INDICATOR:- i) Type:- ii) Make:- iii) Capacity.

2

-

-

... More
Earth leakage circuit breaker relay of recommended make such as (Kilburn/L&T/MEI/ GEC) conforming to BIS- 2516-1977 with upto date ammendment and of suitable range which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. ELCB/ELR:- I)Make :- (CEI approved). ii)Type: iii) Range.

-

-

-

... More
Providing Hour run meter of reputed make for four digit capacity conforming to BIS:722(Latest edition)/recommendations. HOUR RUN METER:- I) Type:- ii)Make:- iii)Capacity:- Hrs.

2

-

-

... More
Suitable three phase voltage monitor relay with all protection and usual indicator and electric siren against single phasing No/ low voltage,high voltage & overloading and phase voltage difference as per IS:3842with upto date ammendments.

2

-

-

... More
Change over switch of reputed make and suitable capacity

2

-

-

... More
Single phase preventor of reputed make and suitable capacity conforming to IS:1248 (P-V)-1983 with upto date ammendments.

2

-

-

... More
Supply of Kirloskar/Leader/KSB/fouress/pellicon make of cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentioned in item No.1.(a) confomring to BIS/API-standards with upto date ammendments for delivery liine of pump).

2

-

-

... More
(Note:- The sluice valve shall conform to BIS-780-1984 latest with upto date ammedments. However, if the seat pressure exceeds the limits prescribed in BIS: 780 then the sluice valves shall be of Cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2) or class 300 ASA (Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).

-

-

-

... More
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelicon make of suitable size Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the normal delivery size of .pump and capable of withstanding nominal seat pressure as mentioned in item No.1 (a) & comforming to BIS/API standard with upto date ammendments for delivery line of pump.

2

-

-

... More
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA-150 (seat pressure 21 Kg/cm^2) or class 300 ASA (Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).

-

-

-

... More
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelicon make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of Rising main as mentioned in item No.1 (c) for with standing normal seat pressure as per item No.1(a).

1

-

-

... More
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA-150 (seat pressure 21 Kg/cm^2) or class 300 ASA (Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).

-

-

-

... More
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelicon make of suitable size Cast Iron double flanged sluice valve (In case suction is +ve ) for suction pipe having size one or two size larger than the suction size of .pump such as velocity of flow in suction pipe is not more than 2.50 mtr/sec.with strainer having net area of its openings equal to three to four times of X-sectional area of flow in suction pipe and conforming to BIS/API standard with upto date ammendments for delivery line of pump.

2

-

-

... More
NOTE:- The sluice valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA-150 (seat pressure 21 Kg/cm^2) or class 300 ASA (Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).

-

-

-

... More
Providing laying,jointing and testing at site suitable size copper PVC insulated armoured power three and half core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/National/IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.

1

-

-

... More
Providing laying,jointing and testing at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/National/IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.

1

-

-

... More
Providing and laying double loop earthing with G.I.wire and strips 600mmx600mmx3mm thick electrode complete with material such as charcoal and common salt G.I.Pipes thimbles nuts and bolts,digging of pits, G.I.Wiring and 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with upto date ammendments suitable for above motors and other electrical equipments i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.

1

-

-

... More
Supply and errection of floor/wall mounted power factor shunt capacitor conforming to BIS:2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/Mager/ Bajaj/ L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T/Kilburn/ Standard/Siemens/Havells make ICTP switches conforming to BIS:4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c cost of carriage of material in all leads and lifts & as directed by Engineer-in-charge.

2

-

-

... More
Supply of 100mm dia circular dia pressure gauge of suitable range & standard make such as Fiebig/Bourden/ Precision/PREGA with all accessories such as stop cock, copper tubing etc.conformfing to BIS: 3624-1987 or latest with upto date ammendments.

2

-

-

... More
Providing and fixing double flanged suction, delivery pipe and common header considering site requirement, NPSH required and available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets 3mm thick as per BIS:2712-1978 nuts and bolts as per 1264-1983 & special upto 5mtrs. away from the outer wall of pump house as per layout drawings approved by Engneer-in-charge. The pipes shall be capable of with standing minimum 1.5 times the total pressure as indicated in item No.1(a) or total dynamic pressure+ surge pressure whichever is more. The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 2.50 mtrs./sec. & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c cost of carriage of material in all leads and lifts and as per directed by the Engineer-in-charge.

1

-

-

... More
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer-in-charge.

-

-

-

... More
Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.

2

-

-

... More
Installation of all the items appearing at Serial No.55.01 to 68.00 as per the systematic drawing attached with the tender documents(Drg. No.1).

1

-

-

... More
Supplying,Installation and testing of micoprocessor based fully programmable Soft Starter suitable for induction motor of 2x40 HP Siemens/ Crompton Greaves / ABB/ Vacon/L&T or equivalent make certified by CE/UL/CSA suitable for motor operation in 360-440 VAC, 3 phase ambient temperature of 25 Deg Cen. Ram up time 0-20 sec. within built by-pass system fully programmable e. i digital display connection with motor etc and all connection needed to make motor pump run sucessfully. The Starter should be offered with cabinet including panel board with accessories of reputed make with ammeter, volt meter, push button & single phase preventor and programmable logic controller ( PLC) for automatic reset for all tripping ( like over voltage,under voltage,over load & short circuit etc.) with level sensors for tank up & down water level, complete in all respects. All digital display connection to make the motor pump run sucessfully. The equipment should be upgradable for use with future automation of the system to meet the parameters as per ANNEX-1 attached.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.