Haryana Police Housing Corporation Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Police Housing Corporation - HPHC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date11 Jul 2024
Closing Date1 Aug 2024
Tender Amount₹ 89,16,47,476 
Notes
Download

Costs

  • EMD

    ₹ 1,78,32,000
  • Document Cost

    ₹ 50,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[10.13.1]Providing and laying cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 1. 18 mm thick

146.82

38613

263

... More
[10.15]Extra for using hardener at top surface (3.5Kg /sqm) of trimix M25 to finish surface complete in all respect

12749.76

2180208

171

... More
[10.29.2]Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement

349.04

276788

793

... More
[10.3]Supplying and providing of Tangri River Sand under floors Including watering and compaction in 25cm layers, dressing etc. complete In all respects (As per item 10.2)

9103.18

4496970

494

... More
[10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick

1351.5

1067685

790

... More
[10.38]Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

78.89

65952

836

... More
[10.40.1]Providing and fixing of 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 1. Red sand stone

349.04

186038

533

... More
[10.47]Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge.

11.79

14313

1214

... More
[10.48]Providing and laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge.

150.84

179047

1187

... More
[10.49.1]Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 1. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

214.21

376795

1759

... More
[10.5]Providing and laying of screed of 40 mm thick cement concrete 1:8:16 to be laid below the topping.

16372

1129668

69

... More
[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

6776.8

18344797

2707

... More
[10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc.

1384.38

3508018

2534

... More
[10.58]Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

2727.3

1467287

538

... More
[10.61]Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.

517.53

391252

756

... More
[10.63.3]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mm

1093.8

1273183

1164

... More
[10.63.4]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 4. Size of Tile 1000x1000 mm

6431.56

8631153

1342

... More
[10.65]Providing and fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.

459.71

115846

252

... More
[10.67.3]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm

96.56

114037

1181

... More
[10.67.4]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 4. Size of Tile 1000x1000 mm

298.68

406204

1360

... More
[10.7]Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4

890.6

192369

216

... More
[10.72]Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles.

7406

29624

4

... More
[10.77]Providing and laying 80mm thick factory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over (BIS 15658:2006) and including 60mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

2348.44

1495956

637

... More
[10.97.1]Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment up to 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment up to 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. (c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip non-combustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology up to 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 1. 300 mm Finished Floor Height (FFH)

189.18

789258

4172

... More
[11.11.1]12 mm cement plaster finished with a floating coat of neat cement of mix : 1. 1:3 (1 cement: 3 fine sand)

526.1

64184

122

... More
[11.121]Polyurethane polish (PU) two or more coats to give required finish including two coat of wood sealer Including Preparation of surface/base complete as per specification

1174.86

296064

252

... More
[11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge

32005.25

7489228

234

... More
[11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand)

25323.31

2177804

86

... More
[11.46]Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 and II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations, finished in smooth line and level etc. complete.

19998

3759624

188

... More
[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)

9895

831180

84

... More
[11.5.4]12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand)

27109.78

1843465

68

... More
[11.54]Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

1000

31000

31

... More
[11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete

60953.85

1950523

32

... More
[11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand)

1500

153000

102

... More
[11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer

31620.29

1422913

45

... More
[11.68.3]Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works

3141.8

59694

19

... More
[11.69.2]Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre

60831.85

1338300

22

... More
[11.71.1]Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work

26412.49

1426274

54

... More
[11.76]Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete.

526

19462

37

... More
[11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade.

5036.8

156140

31

... More
[11.94.1]Finishing walls with textured exterior paint of required shade : 1. New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

5691.09

773988

136

... More
[11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1527.23

134396

88

... More
[12.1.1.1]Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid separately). 1.1. Second class teak wood

3.26

340425

104425

... More
[12.102.1]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm

1072

52528

49

... More
[12.102.2]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm

16

688

43

... More
[12.103.1]Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1. Single rubber stopper

460

12880

28

... More
[12.114]Providing and fixing of roller blinds on windows complete with material and labour complete with push up and down arrangement as per approved design / colour and Engineer-in-charge.

545

1137415

2087

... More
[12.116]Providing and fixing Bamboo Jaffri/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of Hollock wood in scantling of section 50X25 mm, fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge.

100

69900

699

... More
[12.12.2]Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 2. 1.0 mm thick

1806.8

831128

460

... More
[12.130.1]Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 1. Frame work

735

2308635

3141

... More
[12.130.2]Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 2. Openable shutter

294

1410906

4799

... More
[12.130.3]Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 3. Double glass glazing comprising of 6 mm thick toughened clear glass + 12mm air gap + 5mm annealed clear glass.

735

1460445

1987

... More
[12.147]Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).

760

934040

1229

... More
[12.152]Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail and side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for separately).

523

3702840

7080

... More
[12.154]Providing and fixing glazing in fire resistant door shutters, fixed panels and partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, and special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity and radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW and EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm

315

10716930

34022

... More
[12.155.1]Providing and fixing partition up to ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture`s specification and direction of engineer in charge all complete. 1. 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks)

1090.22

1257023

1153

... More
[12.157.1.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)

2715.9

950565

350

... More
[12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

2671.68

1076687

403

... More
[12.158.2]Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 2. Pre-laminated particle board with decorative lamination on both sides

53.55

42250

789

... More
[12.159.2]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

82.52

76083

922

... More
[12.162.2]Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 2. 255 X 19 mm

986

264248

268

... More
[12.169.1]Filling the gap in between aluminium frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 1. Up to 5mm depth and 5 mm width

1199

39567

33

... More
[12.171]Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).

113.82

388695

3415

... More
[12.3.3.1.1]Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 3.1.1. 2nd class teak wood 50x12 mm

2600

293800

113

... More
[12.36.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

263

627255

2385

... More
[12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

903.4

1264760

1400

... More
[12.42]Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).

1166.4

94478

81

... More
[12.6]Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

208

20800

100

... More
[12.75.1]Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 1. 125 mm

92

7544

82

... More
[12.89]Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

417

292317

701

... More
[12.97.1]Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 1. 125x75x4 mm

162

17820

110

... More
[12.98.1]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm

85

17085

201

... More
[12.99.3]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm

8

576

72

... More
[12.99.4]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm

944

58528

62

... More
[13.21.1]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Door Frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter

1854

1755738

947

... More
[13.21.2]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 2. Door Frame of size 125mm x 60mm with 37mm wide double rebate for 35mm door shutter

554

686960

1240

... More
[13.29.1]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

35

2765

79

... More
[13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

31250.53

2593793

83

... More
[13.30.1]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubes

61880

6497400

105

... More
[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

9601.28

3802106

396

... More
[13.5.2]Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 2. 10 x 80 mm

3000

189000

63

... More
[13.5.3]Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 3. 10 x 120 mm

7736

603408

78

... More
[17.13]Granular Sub-Base (Mix in place) Construction of granular sub-base by providing Material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per technical clause 401 of MORT&H technical specifications

698.78

764465

1094

... More
[17.44]Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing, as per clause 601 of MORT&H specifications

1068.05

2196978

2057

... More
[17.5.1]Compacting Original Ground 1. Compacting original ground below road crust Loosening of the ground up to a level of 500 mm below the road crust, watered, graded and compacted at OMC in layers to meet requirement of table 300-2 for embankment construction as per technical clause 305 of MORT&H specifications

2208

117024

53

... More
[17.5.3]Compacting Original Ground 3. Compaction of Earthwork Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications

7360.45

51523

7

... More
[17.72]Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORTH specifications

2145.39

10581063

4932

... More
[17.8.3]Compaction 3. Extra for rolling to specifications

1819.26

49120

27

... More
[18.23.2]Providing and fixing at all height wall panelling with phenol bonded Bamboo Mat board conforming to IS:13958-1994 including providing and fixing to frame work made of 50mm x 50mm hardwood plugs including cutting brick work and fixing in cement mortar and making good the wall etc. and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws all complete as per direction of Engineer-in-Charge. 2. 12mm thickness

648.86

2795937

4309

... More
[18.7]Providing and fixing in position Phenol bonded Bamboo wood flooring with planks of sizes 14mm thick, 1800mm length (minimum) and 130 mm wide(minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials and Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded polyethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bamboo wood planks shall have minimum density of 1000 kg/cum and minimum Hardness 1000 kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.

698.72

3177778

4548

... More
[18.8]Providing and fixing in position Phenol bonded Bamboo wood in wall skirting with planks of sizes 14mm thick, 1900mm length (minimum) and 85mm wide(minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials and Technology Promotion Council (BMTPC). The skirting shall be fixed with SS screws and rawl plugs, over underlayment of 4mm thick, expanded polyethylene foam sheets having 40kg/cum density over prepared surface. The bamboo wood planks shall have minimum density of 1000kg/cum and minimum Hardness 1000 kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.

63.94

280434

4385.9

... More
[20.26.1]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall

50

8200

164

... More
[20.26.2]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall

75

18150

242

... More
[20.28.1]Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 1. 75 mm thickness of roof or floor

50

4250

85

... More
[20.28.2]Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 2. 115 mm thickness of roof or floor

70

7210

103

... More
[20.76.17]Design, Supply and erection of transformer of standard make Required 25 KVA 11/0.433 KVA rating outdoor type 11 KVA V.C.B, panel, G.O. switch, H. Pole , H.T metering panel, APFC panel, battery charges, 11 KVA substation, entire cable network from G.O. switch to H.T metering equipment and from H.T metering to Transformer. From transformer to main to L.T, panel earthling, safety equipment, fenced enclosure for transformer, and any other contingent thereto complete in all respect as per approved make and directions of Engineer-in-charge as per respective capacity. 17. 1000 KVA

2

2192858

1096429

... More
[20.89.14]`Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 V. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s) h) Metering set 60/5A/110V (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size l) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, Dc control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge` 14. 500 KVA

4

12931280

3232820

... More
[21.100.2]Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 2. 100 mm dia pipe

242

154396

638

... More
[21.100.4]Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 4. 150 mm dia pipe

163

151264

928

... More
[21.28]Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge

750

223500

298

... More
[21.93.1]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening

50

57750

1155

... More
[21.93.2]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening

10

10580

1058

... More
[21.93.3]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 3. Type:- Extra Heavy Duty Set (EHD-10) 560MM Clear Opening

10

7720

772

... More
[22.10.1.1]Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1.1. Kitchen sink with drain board 510x1040 mm bowl depth 250 mm

10

37190

3719

... More
[22.101.2.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore

284

14484

51

... More
[22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore

1

292

292

... More
[22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore

20

9140

457

... More
[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore

284

126096

444

... More
[22.14.2.2]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.2. Flexible pipe 40 mm dia

10

570

57

... More
[22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge.

138

101430

735

... More
[22.163.3]Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 3. 200 mm diameter

100

45000

450

... More
[22.163.4]Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 4. 250 mm diameter

415

275145

663

... More
[22.165.2]Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 2. 150 mm diameter S.W. pipe

150

37500

250

... More
[22.165.3]Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 3. 200 mm diameter S.W. pipe

50

14700

294

... More
[22.165.4]Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 4. 250 mm diameter S.W. pipe

745

254790

342

... More
[22.165.5]Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 5. 300 mm diameter S.W. pipe

165

65175

395

... More
[22.166.3.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.1. 180x150 mm size P type With common burnt clay non-modular bricks of class designation 7.5

15

23895

1593

... More
[22.168.2]Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2. 150 mm dia. R.C.C. pipe

100

28400

284

... More
[22.168.3]Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 3. 250 mm dia. R.C.C. pipe

330

152790

463

... More
[22.168.4]Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 4. 300 mm dia. R.C.C. pipe

165

96195

583

... More
[22.168.5]Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 5. 450 mm dia. R.C.C. pipe

15

14460

964

... More
[22.173.1]Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5

14

10808

772

... More
[22.174.1]Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5

4

20468

5117

... More
[22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

85000

595000

7

... More
[22.185.1]Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 1. 50 mm dia

40

176480

4412

... More
[22.186.1]Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 1. 80 mm dia nominal bore

1

2708

2708

... More
[22.192.1.2]Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.2. 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming to IS : 4885

5

29485

5897

... More
[22.193.2]Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m 2. With Sewer bricks conforming IS : 4885

5

17655

3531

... More
[22.194.1.2]Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.2. 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming IS : 4885

40

447680

11192

... More
[22.195.2]Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : 2. With Sewer bricks conforming IS : 4885

40

182920

4573

... More
[22.198.1]Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1. With 20x20 mm square bar

25

6075

243

... More
[22.200.1]Supplying and fixing C.I. cover without frame for manholes : 1. 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg

7

7602

1086

... More
[22.201.1.1]Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 1.1. L D- 2.5 Rectangular shape 600x450 mm internal dimensions

5

4400

880

... More
[22.201.1.2]Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 1.2. L D- 2.5 Square shape 450 mm internal dimensions

5

3700

740

... More
[22.201.2.1]Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 2.1. M D - 10 Square shape 450 mm internal dimension

5

4380

876

... More
[22.201.2.2]Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 2.2. M D - 10 Circular shape 500 mm internal diameter

2

1486

743

... More
[22.201.3.1]Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 3.1. H D - 20 Circular shape 560 mm internal diameter

6

6558

1093

... More
[22.205.1]Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5

32

90272

2821

... More
[22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

15

12195

813

... More
[22.210.4]Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 4. Rectangular shape 1500x450 mm

22

28050

1275

... More
[22.211]Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.

15

7845

523

... More
[22.214]Providing and fixing in position best Indian make C.P. brass Tumbler cum Tooth Brash holder fixed in with rawl plugs with C.P. brass screws and complete including cutting and making good the walls etc.

48

14544

303

... More
[22.216.1]Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge. 1. 25 Litres capacity

8

64688

8086

... More
[22.222.2.1]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete

805

429870

534

... More
[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete

1660

534520

322

... More
[22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

84

907956

10809

... More
[22.34]Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.

15

183000

12200

... More
[22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.

84

20244

241

... More
[22.41]Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.

2

72

36

... More
[22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass

84

32676

389

... More
[22.46]Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

46

255208

5548

... More
[22.83]Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.

80

11040

138

... More
[22.85.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes

840

261240

311

... More
[22.85.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia Pipes

250

107500

430

... More
[22.85.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 6. 50 mm nominal outer dia Pipes

200

129600

648

... More
[22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes

1345

355080

264

... More
[22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes

465

154845

333

... More
[22.88.3]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 3. 25 mm dia nominal bore

565

160460

284

... More
[22.88.4]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 4. 32 mm dia nominal bore

275

96525

351

... More
[22.88.5]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 5. 40 mm dia nominal bore

250

104250

417

... More
[22.88.6]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 6. 50 mm dia nominal bore

200

102600

513

... More
[22.91.3]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 3. 25 mm dia nominal bore

20

4840

242

... More
[22.91.6]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 6. 50 mm dia nominal bore

610

247660

406

... More
[22.91.8]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 8. 80 mm dia nominal bore

200

123200

616

... More
[22.92.2]Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 2. 50 to 80 mm nominal bore

2

1696

848

... More
[22.93.10]Providing and filling sand envelope of grading zone IV or coarser grade,100mm all-round the G.I. pipes in external work : 10. 150 mm diameter pipe

5

850

170

... More
[22.93.3]Providing and filling sand envelope of grading zone IV or coarser grade,100mm all-round the G.I. pipes in external work : 3. 25 mm diameter pipe

20

1240

62

... More
[22.93.6]Providing and filling sand envelope of grading zone IV or coarser grade,100mm all-round the G.I. pipes in external work : 6. 50 mm diameter pipe

610

40260

66

... More
[22.93.8]Providing and filling sand envelope of grading zone IV or coarser grade,100mm all-round the G.I. pipes in external work : 8. 80 mm diameter pipe

200

21400

107

... More
[22.96.1]Providing and fixing brass bib cock of approved quality : 1. 15 mm nominal bore

84

21000

250

... More
[22.98.1]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore

72

29808

414

... More
[22.98.3]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore.

30

14550

485

... More
[22.98.4]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore

46

26082

567

... More
[22.98.5]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 5. 50 mm nominal bore

20

14600

730

... More
[22.98.6]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 6. 65 mm nominal bore

10

12650

1265

... More
[22.98.7]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 7. 80 mm nominal bore

10

18920

1892

... More
[23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required

2245

150415

67

... More
[23.21]Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required

1888

90624

48

... More
[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA

5

33475

6695

... More
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA

6

36780

6130

... More
[23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing)

1

1406

1406

... More
[23.22.4.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.3. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing)

3

5118

1706

... More
[23.22.4.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing)

45

147420

3276

... More
[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)

2

7916

3958

... More
[23.22.4.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing)

50

287750

5755

... More
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole

2076

301020

145

... More
[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE

4

1704

426

... More
[23.22.5.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.7. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs FOUR POLE

5

4550

910

... More
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE

97

125227

1291

... More
[23.22.6.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.1. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 25 A

3

4434

1478

... More
[23.23.6..2]MISCELLANEOUS 6..2. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mm

384

134784

351

... More
[23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mm

905

209055

231

... More
[23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mm

80

31760

397

... More
[23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mm

275

130350

474

... More
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required

41200

1277200

31

... More
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.

10

760

76

... More
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.

2

186

93

... More
[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)

14650

1289200

88

... More
[23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)

25225

2850425

113

... More
[23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)

2000

288000

144

... More
[23.3.6.4]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm)

1000

172000

172

... More
[23.3.6.5]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm)

1000

346000

346

... More
[23.4.1.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C

3236

2297560

710

... More
[23.4.3.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.3. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group C

1413

460638

326

... More
[23.4.4.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C

1080

1009800

935

... More
[23.4.5.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C

500

646000

1292

... More
[23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia.

200

5200

26

... More
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.

23000

736000

32

... More
[23.7.6.3]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia.

500

22500

45

... More
[23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia.

100

5700

57

... More
[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data

911

84723

93

... More
[23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules

463

58801

127

... More
[23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch

441

18081

41

... More
[23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate

150

2700

18

... More
[23.8.11.12]FITTING AND ACCESSORIES 11.12. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. USB Charger, 1000mA, 5V, 1 Module ( For Non residential use only)

455

138320

304

... More
[23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch

22

1804

82

... More
[23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket

441

36162

82

... More
[23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket

22

2728

124

... More
[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt

552

141864

257

... More
[23.8.11.9]FITTING AND ACCESSORIES 11.9. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. T.V. Socket outlet modular type

20

1500

75

... More
[23.8.14]FITTING AND ACCESSORIES 14. Supplying,installation,testing and commissioning of Passive Infrared(PIR) based occupancy sensor with automatic day light dimming feature , programmable type, suitable for connected load up to 10Amp , for mounting height up to 2.8 metre and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.

135

746820

5532

... More
[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.

552

52440

95

... More
[23.9]Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.

51

5559

109

... More
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.

32

87072

2721

... More
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.

600

438000

730

... More
[24.1.12]EARTHING AND LIGHTENING ARRESTOR 12. Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required.

500

63500

127

... More
[24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size.

2500

155000

62

... More
[24.1.16]EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers.

16

14368

898

... More
[24.1.17]EARTHING AND LIGHTENING ARRESTOR 17. Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete.

32

2336

73

... More
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.

32

20864

652

... More
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.

50

168400

3368

... More
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.

114

91314

801

... More
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.

300

108000

360

... More
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.

100

73000

730

... More
[24.2.10]LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level.

15

3600

240

... More
[24.2.2.1]LT CABLE 2.1. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:-2.5 Sq mm to 10 Sq mm 2 to 4 Core

600

93600

156

... More
[24.2.2.2]LT CABLE 2.2. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 16 Sq mm to 35 sqmm 2 to 4 Core

1305

210105

161

... More
[24.2.2.3]LT CABLE 2.3. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 50 Sq mm to 150 sqmm 2 to 4 Core

1305

223155

171

... More
[24.2.2.4]LT CABLE 2.4. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 185 sqmm to 240 sqmm 3 to 3½ Core

395

70310

178

... More
[24.2.2.5]LT CABLE 2.5. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 300 sqmm to 400 sqmm 3 to 3½ Core

790

146940

186

... More
[24.2.4.5]LT CABLE 4.5. Laying of underground cable in pipe /existing open/closed trench etc as required:- 300 sqmm to 400 sqmm 3 to 3½ Core

450

13050

29

... More
[24.2.5.1]LT CABLE 5.1. Laying and fixing of cable on surface/ cable tray etc as required:- 2.5 Sq mm to 10 Sq mm 2 to 4 Core

400

4800

12

... More
[24.2.5.2]LT CABLE 5.2. Laying and fixing of cable on surface/ cable tray etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core

1305

27405

21

... More
[24.2.5.3]LT CABLE 5.3. Laying and fixing of cable on surface/ cable tray etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core

1305

40455

31

... More
[24.2.5.4]LT CABLE 5.4. Laying and fixing of cable on surface/ cable tray etc as required:- 185 sqmm to 240 sqmm 3 to 3½ Core

395

15405

39

... More
[24.2.5.5]LT CABLE 5.5. Laying and fixing of cable on surface/ cable tray etc as required:-300 sqmm to 400 sqmm 3 to 3½ Core

610

28670

47

... More
[24.2.7.1]LT CABLE 7.1. Supply and erection of suitable compression type brass cable glands for underground Cable :- Up to 6 Sq mm cable 2 to 4 Core

80

2560

32

... More
[24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core

70

3150

45

... More
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core

174

13398

77

... More
[24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core

80

8320

104

... More
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core

66

8778

133

... More
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core

18

2970

165

... More
[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core

162

36774

227

... More
[24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm

2

64

32

... More
[24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm

6

426

71

... More
[24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm

54

4914

91

... More
[24.2.8.2]LT CABLE 8.2. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 4 sqmm to 6 sqmm

100

400

4

... More
[24.2.8.3]LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm

50

300

6

... More
[24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm

16

128

8

... More
[24.2.8.5]LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm

12

120

10

... More
[24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm

8

88

11

... More
[24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm

20

300

15

... More
[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm

10

200

20

... More
[24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm

12

276

23

... More
[24.3.3.3]HT CABLE 3.3. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 to 400 sqmm

6

61680

10280

... More
[24.3.4.3]HT CABLE 4.3. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 to 400 sqmm

2

35072

17536

... More
[24.4.2.3]STREET LIGHT 2.3. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 120 cm long, with 30 cm high suitable size pole cap

42

25746

613

... More
[24.4.4.3]STREET LIGHT 4.3. Erection of street light fitting on the pole including the cost of petty material required (irrespective of height/length of bracket) At Pole above 7 metres but up to the height of 9 metres.

42

5082

121

... More
[24.4.6]STREET LIGHT 6. Supply and erection of Three Phase weather proof M.S. box of size 30 cm x 20 cm x 15 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 16 amp TP MCB and 4 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box and necessary connections.

47

61476

1308

... More
[24.4.8.5]STREET LIGHT 8.5. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm

42

658770

15685

... More
[25.1.1]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 1. 300mm dia.

318

1942344

6108

... More
[25.1.10]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 10. 40mm dia.

563

462223

821

... More
[25.1.2]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 2. 250 mm dia

333

1704960

5120

... More
[25.1.3]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 3. 200mm dia.

275

1184425

4307

... More
[25.1.4]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 4. 150mm dia.

430

1188950

2765

... More
[25.1.5]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 5. 125mm dia.

285

679725

2385

... More
[25.1.6]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 6. 100mm dia.

391

741336

1896

... More
[25.1.7]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 7. 80mm dia.

463

735707

1589

... More
[25.1.8]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 8. 65mm dia.

478

642432

1344

... More
[25.1.9]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 9. 50mm dia.

470

483160

1028

... More
[25.3.1]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 1. 300mm dia.

1

17760

17760

... More
[25.3.10]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 10. 40mm dia.

25

33700

1348

... More
[25.3.2]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 2. 250 mm dia

1

15015

15015

... More
[25.3.3]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 3. 200mm dia.

10

89410

8941

... More
[25.3.4]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 4. 150mm dia.

2

9104

4552

... More
[25.3.5]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 5. 125mm dia.

1

3541

3541

... More
[25.3.6]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 6. 100mm dia.

5

13320

2664

... More
[25.3.7]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 7. 80mm dia.

20

40600

2030

... More
[25.3.8]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 8. 65mm dia.

21

38262

1822

... More
[25.3.9]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 9. 50 mm dia.

13

20605

1585

... More
[25.4.1]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 1. 200mm dia.

6

71604

11934

... More
[25.4.2]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 2. 150mm dia.

1

8137

8137

... More
[25.4.4]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 4. 100mm dia.

3

12528

4176

... More
[25.4.5]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 5. 80mm dia.

8

27472

3434

... More
[25.4.6]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 6. 65mm dia.

2

6402

3201

... More
[25.4.7]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 7. 50mm dia.

4

11672

2918

... More
[25.5.1]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 1. 200mm dia.

6

205158

34193

... More
[25.5.2]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 2. 150mm dia.

1

18147

18147

... More
[25.5.3]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 3. 125mm dia.

1

13440

13440

... More
[25.5.4]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 4. 100mm dia.

1

9493

9493

... More
[25.5.5]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 5. 80mm dia.

3

19224

6408

... More
[25.5.6]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 6. 65mm dia.

10

54800

5480

... More
[25.5.7]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 7. 50mm dia.

8

39624

4953

... More
[25.5.8]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 8. 40mm dia.

11

33374

3034

... More
[25.6.1]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 1. 200mm dia.

6

71604

11934

... More
[25.6.2]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 2. 150mm dia.

1

8137

8137

... More
[25.6.3]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 3. 125mm dia.

1

5457

5457

... More
[25.6.4]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 4. 100mm dia.

3

12528

4176

... More
[25.6.5]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 5. 80mm dia.

5

17170

3434

... More
[25.6.6]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 6. 65mm dia.

12

38412

3201

... More
[25.6.7]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 7. 50mm dia.

8

23344

2918

... More
[25.6.8]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 8. 40mm dia.

15

33300

2220

... More
[25.7.1]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheet

30

24360

812

... More
[25.7.2]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 2. Thickness 0.80 mm sheet

900

874800

972

... More
[25.7.3]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 3. Thickness 1.00 mm sheet

1800

2115000

1175

... More
[25.7.4]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 4. Thickness 1.25 mm sheet

10

13980

1398

... More
[26.1]Supplying and stacking at site of work well-decayed farm-yard manure from any available source, approved by the Engineer-in-charge including screening through sieve of I.S.designation 16 mm with 5 km lead.

144

78624

546

... More
[26.10]Maintenance of fine grass lawn for one year including fertilizer application, DAP @ 20gm/sqm, urea 40gm/sqm, watering, weeding, top dressing with good earth and manure mixture 2:1 @ 0.01cum per sqm, maintaining fine level, regular mowing and removal of rubbish with all lifts and leads.

3910.95

175992

45

... More
[26.13.3]Digging holes in all kinds of soil, and refilling the same, with the excavated earth, mixed with well decayed farmyard manure (cost of well decayed farm yard manure to be paid separately) 3. Hole 0.75 metre dia and 0.75 metre deep

2000

42000

21

... More
[26.14]`Supplying and planting in prepared pits and watering, healthy , vigorous growing , permanent trees including ,application of 10 ml chlorpyriphos 20% EC, planting desired disease free, 200 cm to 220 cm height ,5 cm to 6 cm calliper size stem , full of foliage ornamental tree sapling each to be supplied in 30cm x 30cm poly bags, `

500

78500

157

... More
[26.15.1]Maintenance of tree including fertilization, application of insecticide, watering, weeding, training, pruning, 1. Maintenance of tree for one year for the 1st three years of age including weeding, hoeing , plant protection , watering from Deptt. source , application of 10 ml chlorpyriphos four times, 0.0289 cum FYM each,50 gm urea and 50 g DAP twice ,replacement of casualty ,disposal of debris and other activities.etc.

600

234600

391

... More
[26.18]Supply and planting of disease free healthy , vigorous growing more than 75 cm height permanent shrubs in already prepared pits, supplied in 25 cm x 20 cm poly bags , application of 10 ml chlorpyriphos 20% E.C. termiticide each and watering supplied through the tractor tanker.

1000

60000

60

... More
[26.19.1]Maintenance of shrub for one year including weeding, hoeing, plant protection, watering from Deptt. source, application of 10 ml chlorpyriphos four times in a year , 0.0289cum FYM each, 20 gm urea and 20 gm DAP twice, replacement of casualty etc. with same species and same age of plant 1. Individual shrubs

1000

290000

290

... More
[26.20]Supply and Planting rare and specimen tree plants in already prepared pits (Ficus starlight 150 cm height , Terminalia 210 cm height, menatalis , Michelia champaca hybrid more than 180 cm height, Cyprus (Golden juniperous ) more than 180 cm height, topiary of 10 to 12 no. well trimmed bolls of more than 30cm size of Ficus nuda, Ficus retusa, Ficus long island , Ficus panda more than 180 cm height, Golden bottle brush , casurina equistefolia , Bottle palm with stem circumference at base more than 40cm ,Washingtonia palm of healthy clear stem height below leaf more Thant 90 cm ) including , fertilizer and insecticides chlorpyriphos 20 ml per pit, planting of 180cm to 210cm tall sapling in position and flooding with water .specie of plant will be decided by engineer in charge.

400

399600

999

... More
[26.21]Maintenance of specimen tree for one year including weeding, hoeing , plant protection , watering from Deptt. source , application of 20 ml chlorpyriphos four times, 0.0289 cum FYM each,50 gm urea and 50 gm DAP twice ,replacement of casualty ,disposal of debris and other activities.etc.

400

232800

582

... More
[26.22.1]Planting seasonal flower in beds 1. Supply and planting flower beds including digging 30 cm deep bed and refilling of beds with excavated soil and FYM 0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10 ml per sqm , planting of F1 hybrid flower saplings to be supplied in tray pots / thumb pots at 20 cm distance from plant to plant and row to row minimum 25 no . plants per sqm

100

21300

213

... More
[26.26]Supply and planting ground cover plants including digging 30 cm deep bed and refilling of beds with excavated soil and FYM 0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10ml per sqm , planting of saplings at 23cm distance from plant to plant and row to row, minimum 19 no. plants per sqm

100

24200

242

... More
[26.3.6]Supplying at site good earth /soil-less media and/ or organic matter, preparation of top dressing mixture or pot media 0.00 0.00 0.00 6. Spreading of sludge, farm-yard manure or/and good earth in required thickness (Cost of sludge, farm-yard manure or/and good earth to be paid for separately)

144

4320

30

... More
[26.30]Supplying healthy, well branched, well bloomed and Planting rose beds including digging 30 cm deep bed and refilling of beds with excavated soil and FYM 0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10ml per sqm , planting of hybrid Budded rose saplings to be supplied in earthen pots /20cm x20cm polybags , planting of sapling at 45 cm distance from plant to plant and row to row and 5 no. plants per sqm

100

15900

159

... More
[26.34]Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth, mixed with farm-yard manure, supplied at the rate of 1.62 cum per 18 sqm, DAP 0.6kg, Chlorpyriphos 20%EC@ 0.20 litre per 18 sqm and supplying and planting hedge at 30 cm apart in two rows @ 202 no. well trimmed bushy ,multi-branched ,30 cm to 45 cm in height plants to be supplied in 15 cm x 15 cm poly bags per 18 sqm .

1009.64

232217

230

... More
[26.35]Maintaining the hedges for one year including watering, hoeing weeding trimming and shaping ,replacement of casualty as and when noticed, application of Farm yard manure @ 0.0127 m layer over surface, application of insecticide chlorpyriphos @ 2ml per sqm twice , urea @40gm and DAP @10 gm per sqm once in a year.

1009.64

247361

245

... More
[26.4.2]SITE CLEARANCE 2. Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kind of soils .

3910.95

50842

13

... More
[26.413]Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in 35 cm HDPE bags as per direction of the officer-in-charge.

100

26000

260

... More
[26.46]`Supplying and display specimen pot plant of raphis palm , cephorthia palm 150 cm,areca palm 150-180 cm and similar high quality plants of croton petra 3 plants each in 45 cm plastic pots with plastic plate for indoor display at site of work. with fresh foliage,90 cm- 180 cm in height` 6-8 stems per pot, full of leaves, ,and displaying indoor including the cost of material ( garden soil, coco peat, FYM in 2:1:1 proportion),with ,PVC plate. complete in all respects.`

400

316000

790

... More
[26.47]Maintenance of indoor specimen potted plants in 45 cm plastic pot/ earthen pot/ cement pot for one year including watering, application of fertilizer NPK 20:20:20 @30 gm and vermi compost 100 gm twice , manure, snowcem/ apex every month, replacement of pot plate, replacement of 30% pots every year with same quality plant , dead plant with same specie of plant etc.

400

260800

652

... More
[26.48]Supplying decorative plant in 30 cm cement pots for outdoor display at site of work with fresh foliage of 60cm-75 cm in height` 3-4 stems per pot, full of leaves, suitable for earthen pots / plastic pots size 30cm dia and 30cm deep(average size) and displaying including the cost of material ( garden soil, coco peat, FYM in2:1:1 proportion),with ,PVC plate. complete in all respects.

200

64400

322

... More
[26.49]Maintenance of outdoor potted plants in 30 cm earthen / cement pot for one year including watering, application of fertilizer NPK 20:20:20 @20 gm ,and vermi compost 50 gm , manure, snowcem/ apex every month, replacement of pot plate, broken pot, dead plant with same specie of plant etc.

200

82600

413

... More
[26.53]Watering of trees, shrubs, ground covers etc. through tractor tanker of 5000 litre capacity including cost of water with all leads and lifts and including cost of water, fuel ,filling of tanker, watering at site with all leads and lifts as per direction of officer - in-charge.(for 1 No. Tree 30 litres water per plant 27 no . irrigations per year , shrub 20 litres/ per plant 27 no irrigations per year , lawn 2.5 cm layer or 25 litre/sqm 50 no irrigations per year , ground cover / flower bed / rose bed 2.5 cm layer or 25 litre/sqm 40 no. irrigations per year , hedge for 2.5 cm layer or 25 litre/sqm 40 no. irrigations per year , Pot plant 3 litre water daily 250 irrigations per year

50

24000

480

... More
[26.58.1]Supply and installation of garden bench 1. Chair type garden bench with L-shaped sides made of reinforced concrete (M30), thickness 100 mm, overall height 1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation. All materials required to be as per BIS specifications.

50

240700

4814

... More
[26.67.2]Providing and fixing vertical garden panels on aluminium tube (50 x25 x 1.5 mm) frame, or 18.85 kg per sqm weight MS angle and MS pipe frame fixed on wall, with growing media of coco peat, perlite and vermiculite 2:1:1, amended with fertilizers and plants as specified by the engineer in charge including drip irrigation of Netafem, Harvel, Hunter, Rain bird, Jain irrigation systems minimum BIS Standard material , planter used should be virgin plastic, , plants supplied should in coco peat and vermiculite medium and every plants should be of permanent decorative quality height of plants should be 30cm to 45 cm .complete. 2. Outdoor vertical garden

200

1591600

7958

... More
[26.68.2]Maintenance of vertical garden for one year, complete with replacement of plants, panels, drip equipment etc., replenishing decomposed media, watering and fertilization to the entire satisfaction of officer in-charge 2. Outdoor vertical garden

200

183400

917

... More
[26.76]Providing and fixing pair of Plastic dustbins 100 litre volume each, of two different colours, for dry and wet waste, made of virgin plastic to be mounted on MS rectangular hollow section 50 x 25 x 3 mm frames pivoted on 3 MS square hollow section verticals, 1 m above ground, one 35 cm RHS welded to each vertical member at base and grouted in 180 x 40 x 30 cm 1:2:4 cement concrete.

5

53330

10666

... More
[26.77]Supply of well grinded in powder form De-oiled Neem cake in packed gunny bags

10

22820

2282

... More
[26.9.1]Turfing lawns with fine grassing ( selection no.1/ Bermuda and Mexican/Neelgiri grass )including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying of selection no. 1 / Bermuda doob grass and Mexican/Neelgiri grass roots, including supplying and spreading of farmyard manure at the rate of 0.60 cum per 100 sqm, maintenance till weed free turf is formed 1. Planting selection no. 1 grass roots in rows 5 cm apart in both directions .

3910.95

211191

54

... More
[28.12]`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : )400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : )50 N as per ASTM C- 836 4) Recovery from 350% elongation : 95% as per ASTM D 412 5) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr 6) Initial Hardness Shore A : min 60 as per ASTM D 2240 7) Root resistant : protection screed required System includes supply , application and termination of coating all complete as per the manufacturer methodology. Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer’s recommendations. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above vertical wall by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding the cost of protection board. `

3709.68

2667259

719

... More
[28.15]Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

694.02

161706

233

... More
[28.18]Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer`s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

26908.25

8664456

322

... More
[28.19]Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage and water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. sprinkled @0.60kg per sqm or higher as recommended by the manufacturer`s specification over the lean concrete of above cited structures. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 85%, compared control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline dry-shake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

5312.84

1391964

262

... More
[28.30]Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.

2500

1152500

461

... More
[28.6]`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : )400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : )50 N as per ASTM C- 836 4) Recovery from 350% elongation : 95% as per ASTM D 412 5) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr 6) Initial Hardness Shore A : min 60 as per ASTM D 2240 7) Root resistant : protection screed required System includes supply , application and termination of coating all complete as per the manufacturer`s methodology. Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer`s recommendations. Prepare a side gola of 50X50 mm at the junction using polymer modified mortar. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above FFl by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Lay a 150 GSM geotextile layer to protect the coating from external damage on final coating before laying of screed concrete/final finish. It shall be applied as per manufactures specification. Rates are incl of surface preparation, grouting and chemical application only. (Rates for geotextile, protection plaster and final finishes such as screed or Brick bat filling for slope, china mosaic, tiles etc is not included in above item. It will be added as per EIC requirements).`

4082.64

2833352

694

... More
[29.1]Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.

13651.25

4382051

321

... More
[29.2]Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.29.6) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, plus 12mm Air gap plus 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

1168

2650192

2269

... More
[29.3]Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.

233.6

543353

2326

... More
[29.4]Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminium sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.

467.2

618105

1323

... More
[29.5]Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

467.2

665760

1425

... More
[29.6]Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminium sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.

1168

1641040

1405

... More
[3.2.2]By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM 2. Earth

97544

1950880

20

... More
[30.31.1]Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : 1. One or more coats on old work

41

1271

31

... More
[30.94]Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, up to 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal and vertical tubes joint with cup and lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.

13067.73

1581195

121

... More
[31.1]Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed and firmly anchored to the concrete surface by means of `L` shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool and plants as approved by Engineer-in-charge.

500

302500

605

... More
[31.10.3]Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge 3. 75mm thick in Grade M 25 with cement content not less than 330 kg per cum

500

413000

826

... More
[31.14.1]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 1. 8mm dia (hole size 12 mm dia & depth up to 80 mm)

50

14500

290

... More
[31.14.2]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 2. 10 mm dia (hole size 14 mm.& hole depth up to 100 mm) 0 0

600

313200

522

... More
[31.14.3]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 3. 12mm dia (hole size 16mm.& hole depth up to 120 mm) 0 0

65

41470

638

... More
[31.14.4]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 4. 16mm dia (hole size 20 mm dia & depth up to 200mm) 0 0

200

162400

812

... More
[31.14.5]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 5. 20mm dia (hole size 24 mm dia & depth up to 240mm) 0 0

40

39440

986

... More
[32.47.2]Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance = 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 and7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre and 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 2. With 20 mm thick bevelled tegular mineral fibre false ceiling tile (NRC 0.7)

7836.83

11480955

1465

... More
[33.12]Supplying, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.

16

16624

1039

... More
[33.13]Supplying, filling, spreading and levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.

16

16624

1039

... More
[33.14]Supplying, filling, spreading and levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge.

16

16624

1039

... More
[33.15]Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

6

6996

1166

... More
[33.16.3]Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 3. 200 mm dia

2

488

244

... More
[33.17.2]Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 2. 150 mm clamp

2

2382

1191

... More
[33.18.2]Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 2. 150 mm dia

2

472

236

... More
[33.19]Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `V` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge.

12

12360

1030

... More
[33.5]Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four Nos. longitudinal and 9 Nos. cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.

501

514026

1026

... More
[33.6.1.1]Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 1.1. All types of soil 300 mm dia

250

127750

511

... More
[33.8.2]Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 2. 150 mm nominal size dia

30

17820

594

... More
[33.9.2]Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 2. 150 mm nominal size dia

220

141240

642

... More
[34.1.1]Cast in Situ Cement Concrete M20 Kerb Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 1. Using Concrete Mixer

1455.3

317255

218

... More
[34.26]Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

443.02

240116

542

... More
[4.1]Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.

16665.9

99995

6

... More
[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil

59536.54

4643850

78

... More
[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil.

841.06

69807

83

... More
[4.16.1.1]Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.1. All kinds of soil Pipes, cables etc, not exceeding 80 mm dia.

1625

89375

55

... More
[4.16.1.2]Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.2. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

1610

99820

62

... More
[4.16.1.3]Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.3. Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

15

1290

86

... More
[4.31.1]Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil

14535.81

741326

51

... More
[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

24908.3

1145781

46

... More
[6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)

30

119250

3975

... More
[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

8

27808

3476

... More
[6.1.3]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 3. 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)

39.98

136979

3426.2

... More
[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

1094.85

2673623

2442

... More
[6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)

21

46032

2192

... More
[6.13]Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth.

232.69

71203

306

... More
[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

295.77

1808042

6113

... More
[6.22.2.3]Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.3. All works up to Plinth Level : M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)

957.76

2968098

3099

... More
[6.24.1]Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level

6230.03

27829544

4467

... More
[6.24.2]Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level

11543.05

52070698

4511

... More
[6.26.3]Extra for providing richer mixes up to plinth and at all floor levels. 3. Providing M-40 grade concrete instead of M-25 grade BMC/ RMC.(Note : Cement content considered in M-40 is @ 360 kg/ cum)

4577.31

814761

178

... More
[6.27]Extra for R.C.C./ B.M.C/ R.M.C. work above floor IV level for each three floors or part thereof.

3276.48

799461

244

... More
[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete

1114.53

173866

156

... More
[6.30.14]Centering and shuttering including strutting, propping etc. and removal of form for 14. Extra for shuttering in circular work (20% of respective centering and shuttering items)

3013.46

54242

18

... More
[6.30.16.1]Centering and shuttering including strutting, propping etc. and removal of form for 16.1. Edges of slabs and breaks in floors and walls Under 20 cm wide

310.8

35431

114

... More
[6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

9345

2635290

282

... More
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform

27909.77

5805232

208

... More
[6.30.4]Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ)

95.51

21298

223

... More
[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers

23031.43

6817303

296

... More
[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts

17643.24

4622528

262

... More
[6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases

543

157470

290

... More
[6.30.9]Centering and shuttering including strutting, propping etc. and removal of form for 9. Arches, domes, vaults up to 6 m span

1006.43

727648

723

... More
[6.32.1]Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

26333.13

3844636

146

... More
[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. Thermo-Mechanically Treated bars of grade Fe-500D or more.

3258661.15

215071635

66

... More
[6.4]Extra for concrete work in superstructure above floor IV level for each four floors or part thereof.

282.65

89317

316

... More
[6.61.1]Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminium base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it`s components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063). 1. Floor Joint of 100 mm gap

569.5

2546804

4472

... More
[6.62.1]Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings and complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 1. Wall Joint of 100 mm gap

102

373320

3660

... More
[6.63.1]Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminium base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminium base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). 1. Roof Joint of 100 mm gap

90.19

371943

4124

... More
[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand)

268.43

991311

3693

... More
[7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand)

274.19

1230564

4488

... More
[7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand)

11955.33

5834201

488

... More
[7.29]Extra for half brick masonry in superstructure, above floor IV level for every three floors or part thereof by mechanical means.

1847.77

33259

18

... More
[7.30]Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry.

11955

896625

75

... More
[7.51]Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).

2200.2

7949322

3613

... More
[7.76.2.1]Stone work ashlar punched (ordinary) in superstructure up to floor four level in cement mortar 1:6 (1 white cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 2.1. Both faced punched Red sand stone

18.79

230540

12269.3

... More
[8.26.2.1]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.1. Granite of any colour and shade Area of slab up to 0.50 sqm

154.76

425590

2750

... More
[8.26.2.2]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shade Area of slab over 0.50 sqm

108.17

300290

2776.1

... More
[8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work

2639.7

607131

230

... More
[8.28]Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

107

42051

393

... More
[8.32]ALUMINIUM COMPOSITE PANELS Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis and design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material and labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item , as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminium Composite Panel Cladding (including width of groove) shall be measured in sqm up to two decimal places.

584

1445400

2475

... More
[8.5]Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning etc. complete.

170.58

32239

189

... More
[8.7.1.2]Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 1.2. Wedge expansion type Fastener with threaded dia 10 mm

3000

63000

21

... More
[9.11.1]10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10

3257.44

1589630

488

... More
[9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase

2407.35

269623

112

... More
[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

17

2499

147

... More
[9.33]Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm ( plus 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

1970.35

993056

504

... More
[9.46.3]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board

4407.82

3825987

868

... More
[9.47.1]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 1. GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.

629.67

579926

921

... More
[9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter

1516.82

408024

269

... More
[9.58.1.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.3. Coupler 150 mm

204

24072

118

... More
[9.58.3.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.3. Single tee with door 150x150x150 mm

50

10500

210

... More
[9.58.5.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5° 150 mm bend

84

10836

129

... More
[9.58.6.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.3. Shoe (Plain) 150 mm Shoe

154

17402

113

... More
[9.59.3]Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 3. 150 mm

285

43890

154

... More
Supplying, installing, testing and commissioning of AHRI Certified Water Cooled Chiller having mono/ twin screw compressor, capacity minimum 350 TR at actual design condition.The chiller must be provided with VFD., for after sale maintenance ease. Water cooled condenser, insulated chiller, flow/DP switch at chiller and condenser, vibration isolators, integral refrigerant piping and wiring, BMS interface unit (BACNET/MODBUS), grooved/flanged couplings for condenser and cooler water in/out connections, complete charge of refrigerant and oil, accessories as required and called for, automatic and safety controls mounted in central micro-processor based console panel and all mounted on a steel frame complete as per specifications. Motor shall be suitable for 415±10% 50 cycles. 3 phase AC supply and motor cable terminal box shall be suitable to connect Cabling. Refrigerant used shall be Ozone friendly. EM:Trane,Daikin,York,Carrier. Design Condition at Panchkula,Haryana. Evaporator: Chiller Water IN:54.6 °F:Chilled Water OUT:44.6°F:Pressure Drop: 6 MWC:Fouling factor:0.0005 in FPS Condenser: Condenser Water IN:90 °F:Condenser Water OUT:97.5 °F:Pressure Drop:8 MWC:Fouling factor:0.001 FPS Maximum Power Consumed: Not greater than 0.68 IkW/TR at 100% load condition (At Operating Condition).Best Efficiency Chiller will have preferance. NPLV shall be less than 0.37 IKW/TR. Minimum COP (At AHRI conditions) : More than 6.0, As per ECBC 2017 Guideline.Chiller shall be AHRI certified and AHRI selection sheet will be verified at the time of approval. Chiller manufacturer shall be manufacturer of own compressor. Make: Daikin,Trane,Carrier,York. VFD suitable for motor complete with ammeter with CTs, overload protection,under voltage protection, protection against phase reversal and independent single phase preventers etc. complete as required. 1 Set-Microprocessor based control panel with display not less than 10 inch complete with accessories. The chiller controller shall be factory wired and unit mounted on the chiller machine.Separate mounting of chiller controller is not acceptable, so that any shifting of the chiller will not necessitate sensor field wiring. Lot - Refrigerant line accessories comprising of safety valves, angle valves, liquid line indications, liquid level control etc. Liquid line isolation valve shall be provided to isolate refrigerant in condenser for maintenance purposes. Lot- Water Differential Pressure switches at inlet and outlet of condenser and chiller, water drain and air purge valves wherever required. Lot- Victaulic coupling/Flange Connection at the inlet and outlet piping connections of evaporator and condenser of chillers. Lot- Suction line and chiller insulation with minimum 19 mm thick polyvinyl nitrile rubber insulation duly insulated at manufacturer works/Site as manufacturer`s standard. Lot - Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with ant vibration neoprene rubber pads or springs isolator Lot-Factory Charged refrigerant gas and compressor oil. Refrigerant : R134a Refrigerant shall be CFC free, zero ODP and as per ASHRAE safety classification of A1. The price quoted for supply, installation, testing and commissioning of Chilling Unit shall be inclusive of all duties and taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees. 350TR actual capacity. Water chilling machine as described above and at above mentioned operating conditions complete as required. (2 nos working )

2

12432000

6216000

... More
Supply, installation, testing and commissioning of PN16 rated primary chilled water pump with CI Casing, Bronze Impeller, SS shaft, Mechanical Seal(to be easily replaceable without disburing the pump and motor shaft), each pump capable of delivering the specified flow rate comprising the following and complete as per specifications. Pumps shall be BMS compatible. i) End Suction Axial Split Coupled centrifugal pump ii) Suitable HP, TEFC induction motor with Efficiency IE3, class `F` insulation operating on 415 plus 10% volts, 3 phase, 50 cycles AC supply. Note: Contractor must provide necessary vibration isolation arrangement, if required. OEM:Armstrong,Xylum,Lubi Primary Chilled water pumps Water flow rate : 840 USGPM Head : 40 ft. Motor HP : 15.0 HP(suggested) or as per OEM standard Pumps as mentioned above (2W plus 1S)

3

565308

188436

... More
Supply, installation, testing and commissioning of PN16 rated secondary chilled water pump set (with VFD) with CI Casing, Bronze Impeller, SS shaft, Base Frame, Coupling, Coupling Guard,Mechanical Seal(to be easily replaceable without disburing the pump and motor shaft), each pump capable of delivering the specified flow rate comprising the following and complete as per specifications. Pumps shall be BMS compatible. i) Variable Speed End Suction Axial Split Coupled centrifugal pump with motor mounted IP55 factory integrated VFD capable to vary upto 60 Hz depending upon load requirement. VFD must display all critical parameters like amps, volts, frequency, dynamic flow and head of each operating pump. ii) Suitable HP,TEFC induction motor with Efficiency IE3, class `F` insulation operating on 415 plus 10% volts, 3 phase, 50 cycles AC supply. Separate Pump Controller with Sensorless/DPT(Wireless) control to be provided with IP55 protection to maintain the redundancy in Variable Speed Pumping System(VSPS). Pump Controller, controlling the secondary pumps must provide its running status(read only) to Plant Controller through Modbus/Bacnet Protocol.Minimum 4 Nos of wireless DP sensors to be considered in case pump is not sensorless. Pump Controller should have colorful touch screen display and should work on BEP(Best Effciency Point) based staging for Secondary Pumps for optimum efficiency of VSPS system.(The pump logic controller shall be capable of receiving up to 7 remote process variable signals, This selected signal will be used as the commend feedback input for a hydraulic stabilizing function to minimize hunting). Note: Contractor must provide necessary vibration isolation arrangement, if required. Water flow rate : 1090 USGPM Head : 85 ft. Motor HP : 25.0 HP(suggested) or as per OEM standard Pumps as mentioned above (2W plus 1S)

3

2333124

777708

... More
Supply, installation, testing and commissioning of PN16 rated condenser water pump motor set with CI Casing, Bronze Impeller, SS shaft, Base Frame, Coupling, Coupling Guard, Mechanical Seal(to be easily replaceable without disburing the pump and motor shaft), each pump capable of delivering the specified flow rate comprising the following and complete as per specifications. Pumps shall be BMS compatible.i) End Suction Axial Split Coupled centrifugal pump. ii) Suitable HP, TEFC induction motor with Efficiency IE3, class `F` insulation operating on 415 plus 10% volts, 3 phase, 50 cycles AC supply. Note: Contractor must provide necessary vibration isolation arrangement, if required. Water flow rate :1200 USGPM (4617 LPM Approx.) Head : 85 ft. Motor HP : 40.0 HP(suggested) or as per OEM standard Pumps as mentioned above (2W plus 1S)

3

1042554

347518

... More
Supply, installation, testing and commissioning of PN12 rated hot water hot water constant speed end suction pump with CI Casing, Bronze Impeller, SS shaft, Mechanical Seal(to be easily replaceable without disturbing the pump and motor shaft), each pump should be capable of delivering the specified flow rate comprising the following and complete as per specifications. Pumps shall be BMS compatible. i) Constant Speed end suction Axial Split Coupled centrifugal pump. ii) Suitable HP,TEFC induction motor with Efficiency IE3, class `F` insulation operating on 415 plus 10% volts, 3 phase, 50 cycles AC supply Note: Contractor must provide necessary vibration isolation arrangement, if required. Water flow rate :510 USGPM (4617 LPM Approx.) Head : 85 ft. Motor HP : 15.0 HP(suggested) or as per OEM standard Pumps as mentioned above (2W)

2

416358

208179

... More
Supply, installation, testing and commissioning of electrically operated Hot Water Generator of efficiency more than 90% of given capacity in multiple bank complete with PLC based microprocessor controls, electrical panels, stainless steel braided pipe flexible connector etc. confirming to tender specifications section. The pressure Vessel shall be constructed ( Gauge 10mm thick) as per ASME standards and insulated on all sides with 2 layers of 50 mm thick fiberglass of density 32 kg/cum and K value as per ECBC standards with 2mm thick Aluminum cladding as per specifications. The hot water generator will have immersion type heating element having solid CU facing and shall be equipped with all automatic and safety controls such as manual reset, high temperature water outlet, microprocessor based step controller with thermistor sensor to control HWG in stages and recycling relay, on/off switch type thermostat, pilot light, low water cut off and other controls as per manufacturers recommendations. All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The hot water generator shall be suitable for 415±10% volts / 50 cycles, 3 phase power supply. The entire hot water generator shall be factory assembled and tested.The generator shall be complete with safety valve, drain valve, pressure release valve, vent cock, pressure gauge and temperature gauge, electronic pressure switch, complete as required. It should be BMS compatible with RS-485 communication port. (Surface temp should not exceed 45 deg centrigate) It shall be complete with necessary supports for free standing on floor, such that the bottom of the shell is 300 mm above the finished floor level.Anti vibration arrangement of cushy foot mountings is deemed to be included in this item cost. Heating capacity 300 kW (Modular Configuration) Actual at below mentioned conditions Hot water IN : 113 ºF (45 ºC) Hot water OUT : 122 ºF (50 ºC) 300 KW actual capacity Water heating machine (For Winter Heating) as described above and at above mentioned operating conditions complete as required. (1W plus 1S)

2

3960320

1980160

... More
Supplying, installing, testing and commissioning of CTI certified induced draft vertical out-door type FRP cooling tower of stated heat rejection capacity with fiber glass reinforced water basin, PVC fillings with integral louvers and drift eliminators complete with hot water basin, spray system comprising of GI pipe and brass nozzle,either fitted with statically and dynamically balanced axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor having IP-65 protection and IE-3 rated, suitable for operation at 415 ± 10% voltage, 50 Hz A/C 3 phase supply.The outdoor noise criterion for cooling towers, at a distance of 50 meters from the fan shall be NC-45.Therefore, noise level in open areas 50 meters away from towers in any direction shall not exceed 60 DB.The structure of the cooling towers shall be designed for wind and other loads as per IS: 875.Manufacture:Bell,Delta,Advance. The cooling tower shall be complete with powder coated suction screen, make up quick fill arrangement, overflow and drain connections with necessary valves, fan guard and suitable inspection ladder, access arrangement for cooling tower interior, cement concrete foundation, steel/ masonary supporting structure, anti-vibration/spring mountings etc. Design Condition at Panchkula,Haryana. Water Leaving Temperature : 90.0 Deg F Water Entering Temperature : 97.5 Deg F Ambient Monsoon Wet Bulb Temperature for Punchkula 75Deg F Water Flow Rate : 1400 USGPM Cooling Tower as above (2 Working plus 1 Standby)

3

2031120

677040

... More
Supplying, installing, testing and commissioning of water tank for make up water for cooling tower at terrace.All valves acesessaries shall be complete as required. Make-Up Water Tank for Cooling Tower 5000 lts

2

124168

62084

... More
Supply, installation, testing and commissioning of PN 16 rated and Closed Loop Expansion tank and Dirt Air Separator with strainer, auto airvent, insulaton, necessary pneumatic devices and Pressurization unit with two pumps (1W plus 1S), pressure switch and other accessories, the control panel should also be included as per followings. The unit shall be housed in powder-painted canopy suitable for external installation, if required. Make:Emerald, Anergy, Rapidcool,Activeline. 800 Litres Expansion Tank(For Chilled Water)

1

472105

472105

... More
300 Litres Expansion Tank(For Hot Water)

1

309559

309559

... More
Supply, installing, testing and commissioning of horizontal FAN COIL UNITS, blow thru type, each complete with 3 rows deep Chilled Water Coil, one or more centrifugal low noise fans, cleanable fabric filters, main condensate extended SS drain pans, RA insulated plenum, as described in specifications, double skin insulated casing, coil piping connections, through copper pipes, condensate drain connections, wiring, control wiring in flexible conduit upto thermostat boxes location as per site. Make:VTS,Systemair,Stulz,Zeco,Daikin,Flaktwoods 3.0 TR

2

59964

29982

... More
Supply, installing, testing and commissioning of horizontal FAN COIL UNITS, blow thru type, each complete with 3 rows deep Chilled Water Coil, one or more centrifugal low noise fans, cleanable fabric filters, main condensate extended SS drain pans, RA insulated plenum, as described in specifications, double skin insulated casing, coil piping connections, through copper pipes, condensate drain connections, wiring, control wiring in flexible conduit upto thermostat boxes location as per site. Make:VTS,Systemair,Stulz,Zeco,Daikin,Flaktwoods 2.5 TR

2

45730

22865

... More
Supply, installing, testing and commissioning of horizontal FAN COIL UNITS, blow thru type, each complete with 3 rows deep Chilled Water Coil, one or more centrifugal low noise fans, cleanable fabric filters, main condensate extended SS drain pans, RA insulated plenum, as described in specifications, double skin insulated casing, coil piping connections, through copper pipes, condensate drain connections, wiring, control wiring in flexible conduit upto thermostat boxes location as per site. Make:VTS,Systemair,Stulz,Zeco,Daikin,Flaktwoods 2.0 TR

5

114325

22865

... More
Supply, installing, testing and commissioning of horizontal FAN COIL UNITS, blow thru type, each complete with 3 rows deep Chilled Water Coil, one or more centrifugal low noise fans, cleanable fabric filters, main condensate extended SS drain pans, RA insulated plenum, as described in specifications, double skin insulated casing, coil piping connections, through copper pipes, condensate drain connections, wiring, control wiring in flexible conduit upto thermostat boxes location as per site. Make:VTS,Systemair,Stulz,Zeco,Daikin,Flaktwoods 1.5 TR

5

114325

22865

... More
Supply, installing, testing and commissioning of horizontal FAN COIL UNITS, blow thru type, each complete with 3 rows deep Chilled Water Coil, one or more centrifugal low noise fans, cleanable fabric filters, main condensate extended SS drain pans, RA insulated plenum, as described in specifications, double skin insulated casing, coil piping connections, through copper pipes, condensate drain connections, wiring, control wiring in flexible conduit upto thermostat boxes location as per site. Make:VTS,Systemair,Stulz,Zeco,Daikin,Flaktwoods 1.0 TR

5

114325

22865

... More
Supply, Installation, testing and commissioning of AHRI and Eurovent Certified factory fabricated fabricated double skin type Air Handling Units (Ceiling Suspended(CS) /Floor Mounted(FM) AHU)BMS compatible) areas as per specifications given below:- AHU Construction: It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside and 0.8 mm plain steel sheet inside with min 40 mm thick rockwool/PUF insulation between them. Drain pan made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber.AHUs Inner skin of panels and all parts which comes with air contact shall be minimum 22 G anodized aluminum. Necessary foundation required and anti vibration pads shall be provided and cost for the same shall be included in this item.Manufacturers:EDGE TECH, Systemair,Zeco,Flaktwoods 1) Filter section consisting of pre filter and space for ESP filter and UVGI Lamp.2) Plug Fans (with min. 70% efficiency) with motor (VFD compatible) ,volume control damper and duct flexible connection. The supply fan shall be provided with variable frequency drive and input / output signal compatible to BMS system. Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply and high efficiency (IE-3 Efficiency), H.P of motor shall be as per actual selection meeting other technical requirements.3) 6 Row Deep Cooling Coil with aluminum fins.4) Discharge Plenum Section.5) Space For ESP and UV filter along with power / control wiring. Access doors should be fitted with interlocks which will turn off the UV in the event the door is opened. Precaution labels should be posted near access doors to any equipment with UV systems.COIL- Copper tubes and Aluminum fins 10 fin./inch ,AHU Shall be Suitable for BMS operation.Note: All floor mounted air handeling unit( FM AHU) shall have Static Pressure of 60 MM and have Backward curved Fans and all All Ceiling Suspended air handeling unit(CS AHU) shall have Static Pressure of 40 MM and have Plug Fans.However all AHUs final static pressure shall be calculated in the the basis of actual site condition without any implication in cost.Minimum sound level shall be achived based on ducted inlet outlet and on design CFM only.AHU with minimum noise level shall only be selected,technical submittal shall be provided for the same .7.5 TR / 3000 CFM CS AHU

1

212651

212651

... More
7.2 TR / 2900 CFM CS AHU

1

212651

212651

... More
3.1 TR / 1250 CFM CS AHU

1

205703

205703

... More
7.2 TR / 3000 CFM CS AHU

2

425302

212651

... More
11.6 TR / 4700 CFM CS AHU

1

384669

384669

... More
7.2 TR / 2800 CFM CS AHU

1

212651

212651

... More
4.9 TR / 2000 CFM CS AHU

1

205703

205703

... More
8.4 TR / 3400 CFM CS AHU

1

270718

270718

... More
9.6 TR / 3900 CFM CS AHU

1

270718

270718

... More
4.7 TR / 1900 CFM CS AHU

1

205703

205703

... More
9.7 TR / 3900 CFM CS AHU

1

270718

270718

... More
13.6 TR / 5500 CFM CS AHU

1

451839

451839

... More
5.0 TR / 2000 CFM CS AHU

1

205703

205703

... More
3.4 TR / 1400 CFM CS AHU

3

617109

205703

... More
4.6 TR / 1800 CFM CS AHU

1

204917

204917

... More
5.5 TR / 2200 CFM CS AHU

1

212651

212651

... More
5.4 TR/ 2200 CFM CS AHU

1

212651

212651

... More
4.5 TR / 1800 CFM CS AHU

1

205703

205703

... More
8.2 TR / 3300 CFM CS AHU

1

270718

270718

... More
6.9 TR / 2800 CFM CS AHU

1

212651

212651

... More
3.8 TR / 1550 CFM CS AHU

1

204917

204917

... More
4.3 TR / 1800 CFM CS AHU

1

205703

205703

... More
6.3 TR / 2500 CFM CS AHU

1

212651

212651

... More
6.8 TR / 2733 CFM CS AHU

1

212651

212651

... More
6.4 TR / 2500 CFM CS AHU

1

212651

212651

... More
5.8 TR / 2300 CFM CS AHU

1

212651

212651

... More
11.3 TR / 4500 CFM CS AHU

1

384669

384669

... More
9.5 TR / 3800 CFM CS AHU

2

541436

270718

... More
9.3 TR / 3800 CFM CS AHU

1

270718

270718

... More
6.7 TR / 2700 CFM CS AHU

1

212651

212651

... More
6.6 TR / 2600 CFM CS AHU

1

212651

212651

... More
9.8 TR / 4000 CFM CS AHU

1

270718

270718

... More
8.3 TR / 3400 CFM CS AHU

1

270718

270718

... More
6.0 TR / 2400 CFM CS AHU

1

212651

212651

... More
4.0 TR / 1600 CFM CS AHU

1

205703

205703

... More
9.5 TR / 3800 CFM CS AHU

3

812154

270718

... More
6.2 TR / 2500 CFM CS AHU

1

212651

212651

... More
6.5 TR / 2600 CFM CS AHU

1

212651

212651

... More
6.3 TR / 2500 CFM CS AHU

1

212651

212651

... More
47.9 TR / 12632 CFM FM AHU

1

797907

797907

... More
57.1 TR / 14500 CFM FM AHU

1

1040125

1040125

... More
31.0 TR / 12400 CFM FM AHU

1

797907

797907

... More
26.4 TR / 11000 CFM FM AHU

1

620758

620758

... More
11.1 TR / 4500 CFM FM AHU

1

377842

377842

... More
19.3 TR / 7800 CFM FM AHU

1

557638

557638

... More
26.2 TR / 10500 CFM FM AHU

2

1595814

797907

... More
16.2 TR / 6500 CFM FM AHU

1

444145

444145

... More
18.2 TR / 7300 CFM FM AHU

1

557638

557638

... More
17.7 TR / 7200 CFM FM AHU

1

557638

557638

... More
28.8 TR / 11500 CFM FM AHU

1

797907

797907

... More
21.5 TR / 8600 CFM FM AHU

1

620758

620758

... More
11.3 TR / 9000 CFM FM AHU

1

620758

620758

... More
34.0 TR / 11500 CFM FM AHU

1

797907

797907

... More
28.7 TR / 7400 CFM FM AHU

1

557638

557638

... More
24.4 TR / 9300 CFM FM AHU

1

620758

620758

... More
25.5 TR/ 10200 CFM FM AHU

1

620758

620758

... More
32.0 TR / 12800 CFM FM AHU

1

797907

797907

... More
24.1 TR / 9600 CFM FM AHU

1

620758

620758

... More
5.1 TR / 2100 CFM CS AHU

1

205703

205703

... More
4.8 TR / 2000 CFM CS AHU

1

205703

205703

... More
`Supply of 30 W recess mounted LED back-lit 2’x2’ with high efficient LED’s, CCT 5700 - 6500 K,CRI=80, System lumen 110lm/W, Lumens = 3300, white powder coated CRCA with PMMA opal diffuser for glare free and uniform lighting, minimum burning hour life )50000 hours. Driver shall be of constant current type, operating temperature from -10 to plus 45 degree celcius, power factor)0.95, rated voltage 220-240V AC working range:- 140-270 V A`c , 50 Hz plus _ 5%, AC supply. Surge protection - Inbuilt 2.5KV. `

1398

1816002

1299

... More
`Supply of 30 W recess mounted LED back-lit 2’x2’ with high efficient LED’s, CCT 5700 - 6500 K,CRI=80, System lumen 110lm/W, Lumens = 3300, white powder coated CRCA with PMMA opal diffuser for glare free and uniform lighting, minimum burning hour life )50000 hours. Driver shall be of dimmable current type, operating temperature from -10 to plus 45 degree celcius, power factor)0.95, rated voltage 220-240V AC working range:- 140-270 V A`c , 50 Hz plus _ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Manufacturer- As per HPHC Brandlist `

72

222408

3089

... More
Supply, installation, testing and commissioning of recess mounting 18 W LED down light with 50000 burning hours. high efficient LED’s, CCT-5700k -500 K,CRI )80, Lumens = 1800, single piece pressure die cast powder coated housing with opal diffuser for glare free and uniform lighting, Driver shall be of constant current type, operating temperature from -10 to plus 45degree celcius, power factor)0.90, rated voltage 220-240V AC working range:- 140-270 V A`c , 50 Hz plus _ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Manufacturer- As per HPHC Brandlist

1223

500207

409

... More
`Supply, installation, testing and commissioning of recessed mounting 15 W LED down light with 50000 burning hours high efficient LED’s, CCT-5700-6500 K,CRI )80, Lumens = 100lumen/watt, with aluminium die cast housing with opal diffuser for glare free and uniform lighting, Driver shall be of constant current type, operating temperature from -10 to plus 45degree celcius, power factor)0.90, rated voltage 220-240V AC working range:- 140-270 V A`c , 50 Hz plus _ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Manufacturer- As per HPHC Brandlist

2

796

398

... More
`Supply, installation, testing and commissioning of recess mounting 10 W LED down light with 45000 burning hours high efficient LED’s, CCT-5700-6500 K,CRI )80, Lumens = 100lumen/watt, with aluminium die cast housing with opal diffuser for glare free and uniform lighting, Driver shall be of constant current type, operating temperature from -10 to plus 45degree celcius, power factor)0.90, rated voltage 220-240V AC working range:- 140-270 V A`c , 50 Hz plus _ 5%, AC supply. Surge protection - Inbuilt 2.5KV.

155

52855

341

... More
`Supply, installation, testing and commissioning of surace mounting 12 W LED down light with 45000 burning hours high efficient LED’s, CCT-5700-6500 K,CRI )80, Lumens = 100lumen/watt, with aluminium die cast housing with opal diffuser for glare free and uniform lighting, Driver shall be of constant current type, operating temperature from -10 to plus 45degree celcius, power factor)0.90, rated voltage 220-240V AC working range:- 140-270 V A`c , 50 Hz plus _ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Manufacturer-As per HPHC Brandlist `

206

95584

464

... More
Supply and erection of 20 watt LED Betten Tube Light, 4` long suitable with 40000 burning hours for rated voltage 220-240V AC working range:- 140-270 V A`c , 50 Hz plus _ 5%, AC supply with aluminium alloy base,, frosted polycarbonate diffusers with power factor )0.90, Total Harmonic Distortion (THD) ( 20%, system current - 0.085A, system efficiency ) 85% , with operating temp. -10° C to 45° C, Lumen output for LED tube should be ) 2000 lumen and overall lumen/watt of luminaire should be greater than 80%, C.R.I. of LED)80% with correlated colour temperature (CCT) of 6500K , minimum burning hour life )40000 hours,LED viewing angle 120 Degree complete in all respect with the entire satisfaction of the Engineer-in-incharge. Supply of Industrial General Purpose 4` long tube fitting suitable to house 1x20w LED tube rod 4` long, Polycarbonate housing , rated voltage 240 V and Ingress protection IP-20. Manufacturer- As per HPHC Brandlist

775

170500

220

... More
Supply, installation, testing and commissioning of 11 W mirror light with high efficient LED’s, CCT-6500 K,CRI )70, Lumens =900, with Ingress protection IP-20, with 50000 burning hours Driver shall be of constant current type, operating temperature from -10 to plus 45 degree celcius, power factor)0.90, rated voltage 220-240V AC working range:- 140-270 V A`c , 50 Hz plus _ 5%, AC supply. Surge protection - Inbuilt 2.5KV.Manufacturer- As per HPHC Brandlist

33

6039

183

... More
Supply, installation, testing and commissioning of LED Bulkhead with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 5700K and CRI ) 80. The luminaire shall meet IP65 rating and IK 08 rating with THD ( 20% and PF ) 0.9. The luminaire housing should made of pressure die cast Aluminium with polycarbonate front diffuser. The total power consumption should not exceed 6.5W (including driver). Manufacturer- As per HPHC Brandlist

198

90882

459

... More
Supply, installation, testing and commissioning of LED exit signage of Box size in mm 325x425x365 with 50000 burning hours. Manufacturer-As per HPHC Brandlist

70

225050

3215

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.As per HPHC Brandlist

552

1117800

2025

... More
Supplying of Plastic Body Ornamental Exhaust Fan heavy duty 230V A.C 50 cycles, 300 mm sweep, 1300 rpm, energy efficient, complete erected in position with all accessories. Make- Havels- Venti Air DS, or Equivalent to Orient- Ventilator DS, Cromptong and Greaves- Ventilus 250 or equivalent as per specification.As per HPHC Brandlist

51

66402

1302

... More
Supply, Installation, Testing and Commissioning of Wall Mounted Fans of OSC. WALL and CABIN FANS OF 400 MM SWEEP. As per HPHC Brandlist

50

111400

2228

... More
Supply, Installation, Testing and Commissioning of Aviation obstruction light.

1

2742

2742

... More
Supply, Installation, Testing and Commissioning of 4.8 watt/mtr LED Strip Light. Manufacturer- As per HPHC Brandlist

500

171500

343

... More
`Supply, installation, testing and commissioning of Suspended / Surface 28 watt Linear Connect luminaire. Well designed extruded aluminium housing linear profile with efficacy 110 lm/W and perfect optic controls. Suitable for modern open office space with 55mm width, CCT 5700 K. Manufacturer- As per HPHC Brandlist`

25

76075

3043

... More
`Supply, installation, testing and commissioning of 9 watt Recessed mounted deep recessed adjustable/fix downlight for good-quality illumination to enhance the display of retail showroom, passage, corridors, accent lighting, CCT 6500 K. Manufacturer- As per HPHC Brandlist`

30

19740

658

... More
Supply, installation, testing and commissioning of Set of 3 Nos. 100KVA/90 KW UPS. Each UPS of 100KVA should have following specifications in addition to tender requirements : True online double conversions, IGBT Rectifier and inverter based UPS. Three phases Input/ three phase output with SMF batteries complete with MS Fabricated battery rack to accommodate the all battery system, Suitable for 30 Min backup on Full load at 0.8 Load P.f., with required Nos. of Battery with Each UPS, Input voltage operations on mains without switch over to battery : 340-478V at 100% load, 220-478 V @ 50% load. Input power factor 0.99 @ 100% linear load, input THDi less than 5% @ 100% linear load. Output THD is less than 3% for full linear load and Less than 5 % for nonlinear load. Crest factor 3:1, over load 125% for 10 min, 150% for 1 min , ) 151% - 400 msecs or more and should be able to operate continuously at 115% load on bypass mode. Battery Flexible design shall be available from 36 to 42. Battery type should be Valve regulated lead-acid (VRLA). Inbuilt/external Delta - Star Input Isolation Transformer with each UPS Shall be provided, parallel communication port, RS232, USB, EPO and SNMP interface, BMS interface, Dust Filter at Air Inlet point are required. UPS should be latest three level IGBT Converter technology providing a high efficiency of ) = 95.4% from 25% to 100 % load levels (w/o transformer losses). LCD Display indicating all important parameters. To improve the UPS Security over LAN/WAN the SNMP card provided with UPS shall be having Cybersecurity enhancements for IEC / UL 2900-2-2 certification, including stronger encryption, configurable password policy. The card shall work on GIGABIT Speed and should support all major protocols : Gigabit ETHERNET, 10/100/1000 Mbits, auto negotiation, Protocol Support HTTP, HTTPS 1.1, TLS 1.2, SNMP V1, SNMP V3, NTP,TFTP, SMTP, SMTPS BOOTHP/DHCP IP v6 Telnet, CLI, SSH, ARP. UPS shall be provided with Temperature Humidity Sensors to monitor Temperature and Humidity over LAN through SNMP card Software. Battery open rack with top cover, battery interlinks, battery breaker(MCCB), Battery breaker enclosure, battery to UPS cable as required should be provided with UPS systems. UPS system shall be parallelable upto 4 units in case required in future. Each UPS shall be compatible for working in parallel redundant mode with other and should be able to be used with Lithium Ion Batteries if required in future. UPS system shall be latest in technology and should be workable at 100 KVA / 90 KW @ 30 Degree and 100 KVA / 90 KW @ 40 Deg C and 120 KVA / 96 KW at 45 Deg C also. Offered UPS Model shall be type tested in line with IEC 62040-3 standard from third party NABL Approved lab. Manufacturer Eaton/Schneider-APC/Powerware/GE/Numeric

1

5404807

5404807

... More
Supplying, installation, testing and commissioning of Race way made from minimum 2.0 mm thick GI raceway, factory fabricated, with internal partition of the following sizes including providing removable double folded cover of 2.0 mm thick , knock out holes and fixing accessories and coupling, earthing stud for terminating 8 SWG copper earth wire complete as required. Manufacturer- MM ENterprises/Slotco/Anantpower/Ricco 150 mm wide x40 mm deep in ceiling/floor

685

467855

683

... More
Supplying, installation, testing and commissioning of Race way made from minimum 2.0 mm thick GI raceway, factory fabricated, with internal partition of the following sizes including providing removable double folded cover of 2.0 mm thick , knock out holes and fixing accessories and coupling, earthing stud for terminating 8 SWG copper earth wire complete as required. Manufacturer- MM ENterprises/Slotco/Anantpower/Ricco 225 mm wide x40 mm deep in ceiling/floor

400

372800

932

... More
Supplying, installation, testing and commissioning of Race way made from minimum 2.0 mm thick GI raceway, factory fabricated, with internal partition of the following sizes including providing removable double folded cover of 2.0 mm thick , knock out holes and fixing accessories and coupling, earthing stud for terminating 8 SWG copper earth wire complete as required. Manufacturer- MM ENterprises/Slotco/Anantpower/Ricco 300 mm wide x40 mm deep in ceiling/floor

475

560500

1180

... More
Supplying, installation, testing and commissioning of floor/ceiling recessed 2 mm thick pregavanised sheet outlet junction box including providing cover with provision to adjust overall height, knock outs on four sides to accept raceways of specified sizes and cutouts to fix required outlets for following size of race ways with painted GI plate. Manufacturer- MM ENterprises/Slotco/Anantpower/Ricco 200X200X50mm

280

120680

431

... More
Supplying, installation, testing and commissioning of floor/ceiling recessed 2 mm thick pregavanised sheet outlet junction box including providing cover with provision to adjust overall height, knock outs on four sides to accept raceways of specified sizes and cutouts to fix required outlets for following size of race ways with painted GI plate. Manufacturer- MM ENterprises/Slotco/Anantpower/Ricco 275X275X50 mm

250

135750

543

... More
Supplying, installation, testing and commissioning of floor/ceiling recessed 2 mm thick pregavanised sheet outlet junction box including providing cover with provision to adjust overall height, knock outs on four sides to accept raceways of specified sizes and cutouts to fix required outlets for following size of race ways with painted GI plate. Manufacturer- MM ENterprises/Slotco/Anantpower/Ricco 350X350X50 mm

270

196290

727

... More
Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low-Light IR Rugged Dome Camera, 1/2.8` CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux @ F1.6 (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000: Adavance Video Compression technology such as H.265 and H.264 High Profile and MJPEG , Triple stream, 2.7 to 13.5mm 5X motorized focus and zoom lens, Field of View FoV H:96°-26°, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, Dual channel Audio, Alarm: 1In/ 1out, 256GB SD card support, PoE (802.3 af) and 12V DC, Max 6W, IP 66, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant, UL/CSA 62368-1, CE (EN 50130-4), FCC Part 15, EN 55032, RoHS (EN63000) and NDAA Section 889 compliant. AXIS/Bosch/Honeywell/Pelco

60

1095300

18255

... More
Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low-Light IR Rugged Bullet Camera, 1/2.8` CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux @ F1.6 (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000: Adavance Video Compression technology such as H.265 and H.264 High Profile and MJPEG , Triple stream, 2.7 to 13.5mm 5X motorized focus and zoom lens, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, Dual channel Audio, 256GB SD card support, Alarm: In/ 1out, PoE (802.3 af) and 12V DC, Max 6W, IP 66, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant, UL/CSA 62368-1, CE (EN 50130-4), FCC Part 15, EN 55032, RoHS (EN63000) and NDAA Section 889 compliant. AXIS/Bosch/Honeywell/Pelco

85

1733405

20393

... More
Supply, Installation, Testing and Commissioning of Outdoor 1/2.8 inch CMOS 2MP or better, IR PTZ Camera, Effective pixels 1920 x 1080, 2MP, 25 fps: 25x Optical Zoom and 16x Digital Zoom, tripple stream: IR distance: 150 meter: Lens type: Wide 5 to 6mm, Tele 125 to -150mm Motorized Auto focus zoom lens: Memory card slot: Min 256GB support. Minimum Illumination- Sense up on- Color: 0.005 lux color, B/W: 0 lux IR On, WDR 120dB, Edge Video Analysis Video Motion Detection, Intrusion, Lioter, Counter and Tampering, 3DNR, BLC, HLC, White Balance, EIS, Defog, Mechanical switchable IR filter (Auto ICR), Pan Range 360° continuous, Tilt Range -10° to 90°, Pan/Tilt Modes - Pan: 0.1°/s - 180°/s: Tilt: 0.1°/s - 90°/s, Presets 256, Preset Accuracy 0.25 Deg, 16 Patrol and Tours, Alarm I/O - 2In/2Out, 2-Way Audio- 1/1 Channel In/Out, 256GB Memory card slot, 4 individually configurable privacy masks, 8 Region of Interest, POE plus (802.3 at) or 24VAC 3A for indoor/Outdoor application, IP66/67, IK 10: Certifications: ONVIF Profile S/G/T compliant, UL/CSA 62368-1, CE (EN 50130-4), FCC Part 15, EN 55032, RoHS (EN63000) and NDAA Section 889 compliant. AXIS/Bosch/Honeywell/Pelco

4

498860

124715

... More
Supply, Installation, Testing and Commissioning of 64 Channel Network Video Storage Manager - NSM shall have Intel® Xeon Silver 4210, 2.2 GHz or better, Mnimum 32GB RAM, 1 plus 1 1200W hot plug redundant power supply, OS drive: 2 x 240 GB in RAID 1: 12 field upgrade up to 16 TB SATA/SAS hard drive options for Video Recording, Data RAID Level: 0, 1, 5, 6, 10. NIC card 4 x 1GbE supporting network throughput of 800 MBPS, Windows Server 2016 R2 64- bit/Windows10 64-Bit IOT Operating System, Microsoft SQL Server/Express 2016. NSM Shall support upto 128 Cameras @ 1080P, 25fps, 09 Remote Client Licenses inbuilt, Web Clients, Monitor Layout up to 4x4, Digital Signature for Video Clip, Continous and Motion Based Recording options, up to 8X forawrd and backward palyback, Playback search as date/time timeline, time jump FWD/REV, bookmarks, calendar, preview, film strip, event search and SMART Motion Search as a min. NVR shall be ONVIF S/G certified and liested on ONVIF Website. NVR shall Support Two -Way Audio with cameras equiped with Microphone and Speaker. Recording to be concidered for 30 days at 2MP, 25 FPS in RAID 5. AXIS/Bosch/Honeywell/Pelco

3

4298385

1432795

... More
Supply, installation, testing and commissioning of 16TB Enterprise Class Internal Hard Drive - 7200 RPM Class, SATA 6 Gb/s, 512 MB Cache, 3.5`, Compatible with Windows, Windows Server, and Linux. Make : WdSeagate

24

649944

27081

... More
Supply, Installation, Testing and Commissioning of ONVIF Certified Network VIdeo Management Software (VMS) system required to support min 320 Cameras in the same database server for Central Monitoring and Control on need basis as and when required. VMS support UHD, 4K, Full HD resolution, H.265 compression codec, multi-imager/lens cameras and 360° fisheye cameras. The VMS shall have option to support failover features if required in future. VMS shall be licenced for 320 cameras and 05 users clients expandable beyond in the same hardware server to support 2000 cameras and 25 User Clients . The VMS should support network joystick controller, GPU rendering support for H.264 and H.265 decoding , video on demand, Adaptive video throttling over network for Live Video, rule engine, operatore role management, server based Video Motion Detection (VMD), edge storage backfill support, bookmark with manual comment, bookmark based search, timeline search, Preview search, synchronous playback, monitor wall support, surrounding camera mode, Cybersecured with features such as Digital Signing, General Data Protection Regulation (GDPR) compliance, HTTPS and SSL base, smart web client, secured firewall configuration, password expiry, non-recoverable password: support ANDROID and iOS phones, seamless integration with intgegrated Access Control System. AXIS/Bosch/Honeywell/Pelco

1

873004

873004

... More
Supply, Installation, Testing and Commissioning of VMS Client Workstation - Supply, installation, testing and commissioning of Client Workstation as per following specifications: Intel® Core™ i7 10700 , ChipSet Intel® Q470 or better, OS - Genuine Microsoft® Windows 10 Enterprise/IOT 64 Bit, RAM - 16GB, OS - 480 GB SSD/SATA, Graphic Card - In-built Processor Graphics (GPU):Intel® HD Graphics 630 or Intel Q470 Processor or NVidia P1000 or Better, supporting 2 Monitors, 01 LAN 01GBPS, Audio IN and Out, USB3.0, Keyboard and Mouse, associated cables etc complete. HP/Dell/Lenovo

3

280257

93419

... More
Supply, Installation, Testing and Commissioning of 55` 4K UHD(3840 X 2160) resolution, Brightness: 350 Nits, 4000:1 Contrast Ratio, Input: 3x HDMI, USB 2.0 x 2, HDCP2.2, RS232C(in/out), RJ45, H/W : Symmetric Design (same with QxR) Center IR Temperature Sensor Auto Level Wi-Fi(2.4/5.0GHz dual) and BT S/W : Workspace (Microsoft365/VMWare/RDP) Custom Home Auto Source Switching and Recovery Dicom Simulation Mode Director Mode SmartView plus (PC) [end of march~] Upgradable Web-Engine Tizen Enterprise Platform Smart Calibration SmartView plus (mobile) Video Conference Solution. 802.1x(WPA2 Enterprise) : EAP-TLS, EAP-TTLS, EAP-PEAP. Make: Sony, Panasonic, Samsung

6

363456

60576

... More
`Supplying and Fixing of Floor Standing Network Rack - 22U / 600w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top and Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 22U/800d Front MS Door perforated honeycomb 22U/600w Rear MS Door (Fully Perforated - Mesh) 22U/600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, Stationery 475mm N/W PDU 7Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Vertical Cable Channel 50mmW 22U complete in all respect. Sudpi/Rittal/Middle Atlantic `

2

62002

31001

... More
Supply, Installation, Testing and Commissioning of 24-port Cat-6A Straight loaded Jack Panel for with labels and clear label covers, Height, 1U The entire CAT6A Shielded Solution must be compliant with the latest ISO 11801 AMD 1 Class EA, Jack Panel shall be RoHS Compliant . UL listed and ETL tested, self-adhesive, clear label holders (transparent plastic window type) and white designation labels with the panel, with optional color labels / icons. Cisco / Juniper / Ruckus/Extreme/Alcatel

11

108185

9835

... More
Supply, Installation, Testing and Commissioning of 48-port Cat-6A Straight loaded Jack Panel for with labels and clear label covers, Height, 1U The entire CAT6A Shielded Solution must be compliant with the latest ISO 11801 AMD 1 Class EA, Jack Panel shall be RoHS Compliant . UL listed and ETL tested, self-adhesive, clear label holders (transparent plastic window type) and white designation labels with the panel, with optional color labels / icons. Molex/Siemon/Panduit/Legrand

21

429513

20453

... More
Supply, Installation, Testing and Commissioning of CAT6A SHIELDED MOUNTING CORDS (2Mtr.) The work area equipment cords shall, be comply with TIA/EIA- 568-B.2-10 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair Category 6A Cabling.Mechanical Characteristic: Cable Conductor size: 26 AWG stranded bare copper,Mechanical Characteristic: Plug-Max O.D.: max 6.1 mm for lockable patch cords and 6.5mm for normal Patch Cords, Patch Cord Jacket: The jacket of the patch cord must be LSZH,Temperature range: -20°C to plus 60°C, Operating life: Minimum 750 insertion cycles, Plug dimensions and tolerances compliant with FCC Part 68 and IEC 60603-7, ElectricalCharacteristics:- Plug. Molex/Siemon/Panduit/Legrand

911

255991

281

... More
Supply, Installation, Testing and Commissioning of CAT6A SHIELDED MOUNTING CORDS (1 Mtr ) The work area equipment cords shall, be comply with TIA/EIA- 568-B.2-10 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair Category 6A Cabling.Mechanical Characteristic: Cable Conductor size: 26 AWG stranded bare copper,Mechanical Characteristic: Plug-Max O.D.: max 6.1 mm for lockable patch cords and 6.5mm for normal Patch Cords, Patch Cord Jacket: The jacket of the patch cord must be LSZH,Temperature range: -20°C to plus 60°C, Operating life: Minimum 750 insertion cycles, Plug dimensions and tolerances compliant with FCC Part 68 and IEC 60603-7, ElectricalCharacteristics:- Plug. Molex/Siemon/Panduit/Legrand

911

156692

172

... More
CAT6A  SHIELDED RJ45 JACK Information Outlets, Category 6A Shielded Jack shall be specifically designed for high-11801 A1.1 draft and ratified TIA/EIA 568-B.2-10 for the support of 10G BASE-T,All information outlets for 22-24 AWG copper cable shall: Use insulation displacement connectors (IDC), 568A/B configuration, The jack should be UL certified, Mechanical Characteristic:IDC Connector Rack Side yellow for data, Plastic Housing must be Polycarbonate, UL94V-0 rated, Contact Force 100g minimum

911

173090

190

... More
`Supplying and Fixing of Fiber Optic LC style fully loaded Patch Panel 24 Port and Upgraddable Up to 96 Port(FOPP), The enclosure must, have a sliding drawer for ease of reconfiguring fibres, incorporates a heavy duty ball bearing slide mechanism, allowing easy access to fibres, Height 1 U-1.75 inches, The LIU must be upgradable up 96 ports LC Style,Dimensions-482mm W x 254mm D x 43mm H( Rackmount),305mm W x 254mm D x 43mm H (Wallmount , Material-Powder coated Mild Steel,Rugged steel construction in graphite finish,Rear, side and base access for Incoming / Outgoing fiber cables,Cable Management, Management rings within the system to accommodate excess fibre cordage behind the through adapters and maintain fibre bend radius.Sliding cover- Panel cover is of slide out for easy maintenance,Splice Tray, 48Fiber Splice Tray of Moulded ABS material should be supplied for the LIU. `

3

43650

14550

... More
Supplying and Fixing of Fiber Optic LC style fully loaded Patch Panel 12 Port and Upgraddable upto 96 Port(FOPP), The enclosure must, have a sliding drawer for ease of reconfiguring fibres, incorporates a heavy duty ball bearing slide mechanism, allowing easy access to fibres, Height 1 U-1.75 inches, The LIU must be upgradable up 96 ports LC Style,Dimensions-482mm W x 254mm D x 43mm H( Rackmount),305mm W x 254mm D x 43mm H (Wallmount , Material-Powder coated Mild Steel,Rugged steel construction in graphite finish,Rear, side and base access for Incoming / Outgoing fiber cables,Cable Management, Management rings within the system to accommodate excess fibre cordage behind the through adapters and maintain fibre bend radius.Sliding cover- Panel cover is of slide out for easy maintenance,Splice Tray, 12Fiber Splice Tray of Moulded ABS material should be supplied for the LIU.

13

142831

10987

... More
Supplying and Fixing of Fiber Optic Patch Cable (LC-LC),Fiber OpticPatch CordsCable-LC-LC 50/125 µm, OM3 Multimode  Duplex Patch Cord,50/125 µm, OM3 MM, Duplex Zipcord, Connectors-The optical fiber patch leads shall comprise of Multi-mode 50/125µm OM4 fiber with 2XLC type fiber connectors terminated at one end and 2X LC type fiber connectors at other end of the patch cord, Cordage O.D,(Duplex): 2.0mm ± 0.1mm x 4.1± 0.2mm, Buffer Diameter, 900µ tight buffer- Jacket Material,LS0H IEC 61034-1 and 2,IEC-60332-1, IEC-60754-1 and 2, Standards-ISO/IEC 1108:2008, ANSI/TIA/ EIA 568.C.3, ANSI/TIA/EIA-492, TELECORDIA GR-409, ICEA-596, Operating Temperature.

45

73485

1633

... More
Supply and Fixing of Fiber optic pigtails-Multimode OM3 Pigtails with LC connector, Type-50/125 micron OM4 fibre performance, Cordage Outer Diameter:2.0mm ±0.1mm x 4.1 ± 0.2mm, Buffer Diameter:-900µm,Primary Coating : 245µm, Attenuation-@ 850nm :- 3.0dB/km : @ @1300nm :- 1.5 dB/km, Jacket Material:LSZH, IEC 61034-1 and 2, IEC-60332-1, IEC-60754-1 and 2, Standards- ISO/IEC 1108:2008, ANSI/TIA/ EIA 568.C.3, ANSI/TIA/EIA-492, TELECORDIA GR-409, ICEA-596

135

29700

220

... More
Supply, installation, testing and commissioning of Cooling and Heating digital thermostat for various fan coil units as described in specifications. The thermostat shall be proportionatory type for modulating 2 way valve with digital temperature indicator.

40

149920

3748

... More
Supplying, Installation, Testing and Commissioning of 50, 12-core Multi mode OM3 metallic armored Fiber cable as per ISO/IEC-11801, Shall be able to meet Gigabit and 10 Gigabit Ethernet performance up to 300 meters requirement specified by IEEE 802.3z (1000 Base-X) and IEEE 802.3ae (10G Base-X) Tensile load should be 4000 Newton or higher and crush resistance should be 4000 Newton or higher ,The attenuation @ 850 nm should be ? 2.7 (Max) db/Km and @ 1300 nm should be ? 0.7 (Max) dB/Km,the fiber construction can be unitube or multitube, but tensile and crush resistance parameters should be matched, the jacket shall be FRLSZH complete in all respect. Molex/Siemon/Panduit/Legrand

1300

178100

137

... More
Supply, installation, testing and commissioning of latest generation digital display type BMS compatible thermostat / humidistat Thermosta for CS and FM AHU (Proportional type)with controller for cool / heat application suitable for two/four pipe system and humidistat suitable for working with humidifier and hot water coil control valves for various air handling Units. The thermostat shall have provision of setting of space temperature and display of the same. The humidistat shall have provision of setting space RH and display of the same. The quoted price of thermostat / humidistat shall include the cost of 20mm flexible conduits , control cabling, MS Box etc. as required. The cost quoted shall be excluding the control valves and humidifier. It shall include all accessories ,mountings, wiring between thermostat and unit, terminations etc.(BMS Compatibility to be provided).

40

472080

11802

... More
Supplying and Fixing of Floor Standing  Network/Server Rack - 42U / 600w / 800d,  with Heavy Duty Extruded Aluminium Frame for rigidity.  Top cover with FHU provision. Top and Bottom cover with  cable entry gland plates.  Two pairs of 19” mounting  angles with ‘U’ marking. Depth support channels - 3 pairs.  With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 42U/800d  Front MS Door Perforated honeycomb 42U/600w  Rear MS Door Split Perforated honeycomb 42U/600wFan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Vertical Cable manager 80mmW 42U  Shelf, Stationery 700mm N/W  PDU 12Sockets 5/15Amps with MCB Mounting Hardware (Pkt. Of 20) earthing Kit 150mmH Cable manager 1U MS with Loops complete in all respect. Sudpi/Rittal/Middle Atlantic

1

38602

38602

... More
Supplying and Fixing of Floor Standing Network Rack - 12U / 600w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top and Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 12U/800d Front MS Door perforated honeycomb 22U/600w Rear MS Door (Fully Perforated - Mesh) 12U/600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, Stationery 475mm N/W PDU 7Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Vertical Cable Channel 50mmW 12U. Sudpi/Rittal/Middle Atlantic

2

29100

14550

... More
Supply, installation, testing and commissioning of duct mounted Air Purification System with AOP cell technology comprising of UVC lamp 254 NM with nanoX metallic compound coating of five metals targeted on Alumninum matrix cell duly enclosed by a poly quartz casing tube, with the capability to produce ionized Hydroxyl oxidizers with in-built plasmoX to generate ion generator pins ( plus - ions 10^6) along with ultrasonic radio frequency waves for pest repellancy. The UV-C lamp will be a low-pressure mercury type and of such intensity as to provide minimum performance as listed below. The UV-C lamp will produce only Germicidal UV (by definition this means 99.99% UV-C energy). The airpurifier will have built in LED indication system stating the operation of the 3 technologies the UV lamp, ionizer and pest repellant. The AOP cell shal be capable of removing Microbial Contamination as well as Particulate matter, Gasous Contamination . The power / control cabling between the Pentagon units and the power source / controls shall be included in the cost . The wattage of the lamp shall not be less than 21 watts upto 6500 CFM ,36 watts upto 18000 CFM and a minimum of 48 watts upto 28000 CFM or combination based on the application area. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall have to GREENPRO,TUV,CE, ISO 13485, ROHS with 2014/35/EU Low Voltage Directive along with FDA compliance certifications.The AOP cell shall a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from CCMB lab with an minimum efficiency of 99 percent against SARS COV2 within 45 minutes. The technology shall be tested by ICMR/ IIT on human Alveolar Basal Epithelial Cells stating that there is no change in the structure and prove that it is absoluely safe for humans. The air purfication AOP does not produces ozone, the test certificate shall be produced. The specific certifications shall be submitted along with the technical submital. The failure to submit the certifications along with the submital shall lead to rejection of the product. The AOP cells should be selected by considering a load factor calculation for each specific area where the equipment is to be installed. The Cells Should be complete with Transformers, control cabling and Plug Top and necessary power cable. Vendor to comply all Tender Specifications.Technical submittals with supported catalog shall be submitted for approval prior to procurement. Quoted price shall be inclusive of all necessary arrangement as required for fixing the same within AHU, control wiring etc. and functional properly.Make: Ultrapure,BEC,Eflow. 47.9 TR / 12632 CFM FM AHU

1

105997

105997

... More
AOP cell 57.1 TR / 14500 CFM FM AHU

1

105997

105997

... More
AOP Cell 31.0 TR / 12400 CFM FM AHU

1

105997

105997

... More
26.35 TR /11000 CFM FM AHU

1

105997

105997

... More
11.13 TR / 4500 CFM FM AHU

1

77459

77459

... More
19.3 TR / 7800 CFM FM AHU

1

105997

105997

... More
26.2 TR / 10500 CFM FM AHU

1

105997

105997

... More
16.2 TR / 6500 CFM FM AHU

1

77459

77459

... More
18.2 TR / 7300 CFM FM AHU

1

105997

105997

... More
26.2 TR / 10500 CFM FM AHU

1

105997

105997

... More
17.7 TR / 7200 CFM FM AHU

1

105997

105997

... More
28.8 TR / 11500 CFM FM AHU

1

105997

105997

... More
21.5 TR / 8600 CFM FM AHU

1

105997

105997

... More
11.3 TR / 9000 CFM FM AHU

1

105997

105997

... More
34 TR / 11500 CFM FM AHU

1

105997

105997

... More
28.7 TR / 7400 CFM FM AHU

1

105997

105997

... More
24.4 TR / 9300 CFM FM AHU

1

105997

105997

... More
25.5 TR/ 10200 CFM FM AHU

1

105997

105997

... More
12800 CFM/ 32 TR FM AHU

1

105997

105997

... More
9600 CFM/ 24.1 TR FM AHU

1

105997

105997

... More
Supplying and Fixing of Floor Standing Network Rack - 9U / 600w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top and Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 12U/800d Front MS Door perforated honeycomb 22U/600w Rear MS Door (Fully Perforated - Mesh) 12U/600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, Stationery 475mm N/W PDU 7Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Vertical Cable Channel 50mmW 9U. Sudpi/Rittal/Middle Atlantic

11

86229

7839

... More
Supply Installation Testing and Commissioning of switch with minimum Twenty Four (24) 1G PoE RJ45 ports and should have Four (4) 1G/10G/25G QSFP28 Slots, from Day 1.Each Switch should be loaded with 2(Two) Multimode SFP plus tranceiver from day 1,support Stacking up to 12 Switches with than 100Gbps stacking bandwidth per Switch,USB-C serial Port,RJ45 Serial port and RJ45 OOB access for management, it shoould also provide USB-A Port for remote updates and backup,Switching Bandwidth: Should provide Non-Blocking switch fabric capacity of 248 Gbps or more.,4Gb DRAM and 8Gb FLASH with 4Mb Packet buffer, support IP Source Guard, DHCP snooping, DHCPv4, DHCPv6 and Dynamic ARP Inspection, support RADIUS, TACACS/TACACS plus and username/password for Authentication, Authorization and Accounting (AAA) ,PoE Power Budget: The PoE Switch should provide a minimum of 370 watts of PoE plus power, Integrated Standard based Command Line Interface (CLI), Telnet, TFTP, HTTP access to switch management/monitoring. Cisco / Juniper / Ruckus/Extreme/Alcatel

10

846280

84628

... More
Supply Installation Testing and Commissioning of minimum Fourty Eight (48) 1G PoE RJ45 ports and should have Four (4) 1G/10G/25G QSFP28 Slots, from Day 1.Each Switch should be loaded with 2(Two) Multimode SFP plus tranceiver from day 1,Stacking up to 12 Switches with than 100Gbps stacking bandwidth per Switch,USB-C serial Port,RJ45 Serial port and RJ45 OOB access for management, it shoould also provide USB-A Port, 4Gb DRAM and 8Gb FLASH with 4Mb Packet buffer, support for IGMP v1, v2, v3 and MLD v1 and v2, minimum 16K IPv4 routes or more and 16K Multicast routes or more, support for IGMP v1, v2, v3 and MLD v1 and v2, support RADIUS, TACACS/TACACS plus and username/password for Authentication, Authorization and Accounting (AAA), Integrated Standard based Command Line Interface (CLI), Telnet, TFTP, HTTP access to switch management/monitoring, PoE Power Budget: The PoE Switch should provide a minimum of 370 watts of PoE plus power. Cisco / Juniper / Ruckus/Extreme/Alcatel

19

2087492

109868

... More
Supply Installation Testing and Commissioning of Switch shall have 24x 1G/10G SFP plus Ports and 2x 40G QSFP plus Port from Day 1 , Switch shall support Virtual Switching System (VSS) or Virtual Chassis (VC) or equivalent Switch Clustering/Stacking feature , where the Switch Clustering feature shall combine 12 switches into a single network element, Switching Bandwidth: The Switch shall provide Switch Fabric Bandwidth Capacity of 1080 Gbps or more, Forwarding Capacity: The Switch shall provide Packet Forwarding Capacity of 803 MPPS or more, Switch should be upgradeable to support 200G for future use/scalability, IPv4 and IPv6 Routing protocols and multicast routing available from day 1,RIP v1 or v2, RIPng, OSPFv2, OSPFv3, BGP4, BGP4 plus , Multi-VRF, VRRP for both IPV4 and IPV6 protocol ,VRRPv2 and VRRPv3, PIM-SSM, PIM Sparse, PIM Dense, PIM Anycast RP, and PIM passive IPv4 multicast routing, PIM-SSM, PIM Sparse, PIM Anycast RP, MSDP and PIM6-SM Snooping IPv6 multicast routing, minimum 128 instance of VRF , support 500 routed virtual instance(RVI), RADIUS, TACACS/TACACS plus and username/password for Authentication, Authorization and Accounting (AAA) with Local User Accounts and Local User Passwords, IP Source Guard, DHCP snooping, DHCPv4, DHCPv6 and Dynamic ARP Inspection,It shall support Integrated Standard based Command Line Interface (CLI), Telnet, TFTP, HTTP access to switch for management/monitoring,The Switch shall be configured with hot swappable, redundant load sharing AC power supplies to provide 1:1 or N plus 1 power supply redundancy or better. Cisco / Juniper /Alcatel

1

979902

979902

... More
Supply Installation Testing and Commissioning of Access Point should be dual-band, dual-radio indoor access point, AP should have 2x2 MIMO on 2.4GHz and 2x2 on 5GHz antennas for transmission and receiving.Should support MU-MIMO, AP should have capacity to handle minimum 250 Concurrent devices, IPv6 support, IEEE 802.1Q, Band balancing, airtime fairness, QoS, L2/L3/L4 ACL, WPA2-AES, Dynamic PSK, WPA3, IEEE 802.1X/EAP, Role-Based Access Control, rate-limiting, device fingerprinting, operating temperature of 0-40 ºC. Cisco / Juniper / Alcatel

60

1496580

24943

... More
Supply Installation Testing and Commissioning of WLC Management should be in physical appliance with 4x1G RJ-45 ports and 4 x 1/10G SFP plus ports, Controller should be able to manage 150 AP and 20 switches from day one and should be scalable up to 500 APs and 50 switches in single hardware, WIRELESS SECURITY and Authentication: Open, 802.1x/EAP, PSK, WISPr, WPA, WPA2-AES, WPA-TKIP, WEP,EAP-SIM, EAP-AKA over WLAN for 802.1x, Authentication through external Radius /Directory services, System must support Band Steering where 5 Ghz clients are forced to connect over 5Ghz Radio to provide better load balancing among 2.4Ghz and 5Ghz Radios. Cisco / Juniper / Alcatel

1

890820

890820

... More
Supplying Installation testing and Commissioning of Small Form Factor Pluggable 10 Gigabit Ethernet (SFP plus ) SR optics.

55

734910

13362

... More
Supply Installation Testing and Commissioning of IP-PBX System Configured as per below with Expandable of up to 896 Extensions. Alcatel/Avaya/NEC SIP Trunk - 30 Analgoue Extension: 400 IP Extension: 51 Attendant Console - 1 NMS Auto Attendant 2 Channel Expandable to 16 Channels Voicemail - 2 Channel Expandable to 16 Channels with 120 Hours of recording Voice mail to e-mail for all users Built in Automatic Route Selection - Least cost routing Remote Maintenance Facility Web Based Managment Software DISA and DOSA Facility Rack Mountable System Supports CTI integration Supports Battery Back-up minimum 10mints Should support WLAN/DECT Phones Boss secretary function 2 mins. Customizable music on hold 32 party Conference Bridge 4 Party Video Conference Bridge UC Suite:- 512 clients with external server, 128 clients without external server* Support DECT Connectivity External Caller Line Identification on BRA/PRI Lines Internal CLI on Digital Phones and Analog CLI Phones

1

606455

606455

... More
Supply, Installation, Testing, commissioning of IP Phone Type-1 Basic IP Phone with high quality audio,Monochrome 132 x 48 Graphiic Display, should offer support for 1 line, 2 call appearances and includes 3-way voice conferencing to maximize productivity. Additional features include LCD screen for easy viewing, 3 XML programmable soft keys for customization, 10/100 Mbps ports, integrated PoE, EHS support for headsets and multi-language support. Alcatel/Avaya/NEC

30

87660

2922

... More
`Supply, Installation, Testing, commissioning of IP Phone Type-2 with Monochrome, 168x41 LCD,6-button and 12-button version (fixed),Backlit LCD,Multi-colour MWI Hands-free, full duplex,Headset support, optional EHS support,Adjustable stand - 5 steps, Soft keys/LCD prompts,Navigation cursor and Directory dial key`,Network support 10/100 Ethernet/1G via licence),PoE,Wideband audio support,Wall mountable. Alcatel/Avaya/NEC `

21

113001

5381

... More
`Analogue Telephone  Caller ID 30 Call Log 5 Re-Dial memory LCD (7 Segment 2 Line) Handsfree Speaker Phone Slim Design Batteries not required, draws power from Telephone line/PBX Alcatel/Avaya/NEC `

400

399200

998

... More
Supply, installation, testing and commissioning of Client Workstation as per following specifications: Intel® Core™ i5 10700 , ChipSet Intel® Q470 or better, OS - Genuine Microsoft® Windows 10 Enterprise/IOT 64 Bit, RAM - 16GB, OS - 480 GB SSD/SATA, Graphic Card - In-built Processor Graphics (GPU):Intel®s, 01 LAN 01GBPS, Audio IN and Out, USB3.0, Keyboard and Mouse, associated cables etc complete.

2

99772

49886

... More
MDF (SUB RACK) with Krone Modules

1

12471

12471

... More
MDF (SUB RACK) with Krone Modules-100 Pair

6

20310

3385

... More
MDF (SUB RACK) with Krone Modules-50 Pair

4

10332

2583

... More
Supplying and Laying of 50 Pair Riser Cable

980

224420

229

... More
Supply of Addressable Control Module for monitoring the field devices.

72

173304

2407

... More
Supply Installation Testing and Commissioning of Class -D Single Channel 500W Power Amplifier, Class-DPA power ampli¬er of minimum power consumption, Speaker outputs 4-16 /100V, Each channel with high-cut ¬alter, Separate indicators for protection, clip, input and output, Frequency Response-L/H Cut OFF 20Hz - 20KHz ( plus 1/-2dB), L/H Cut OFF 20Hz - 20KHz ( plus 1/-2dB), Input-0.775V, 0dBu, balanced phonenix connector, S/N Ratio-)80dB. Heinrich / Honeywell / Bosch

10

353370

35337

... More
Suplly Installation Testing and Commissioning of Access Control panel should support 4 wiegand reader to restrict the entry of unauthorised people at 4 Door as well as restrict the exit of unauthorized person with CPU-ARM 32 Bit RISC Processor, Memory-Up to 8 MB (Flash), No. of Doors-4, No. of Readers-8, Events/Transactions-400000, No. Users-100000, Reader Interface-Weigand (Up to 34 bit), Input-12 inputs (4- Door Status, 4- Egress, 1- Fire and 1- intrusion and 2 Extra input), Output-8 outputs (4 - DOTL, 4 – Lock), Protocol-TCP, UDP, TCP Push, UDP Push, Communications Port-TCP/IP,RS485, Door Interlocking/Man Trap-Yes, Fire Integration -Yes, Intrusion Integration-Yes, LCD-16X2 LCD Display, Keypad -4X3 Key with soft keypad , Baud Rate-9600bps (Default), Controller ID-Up to 9999, It should work Temperature Range upto 50 deg C. Cardex / Lenel / Bosch

23

421245

18315

... More
`Supply Installation Testing and Commissioning of Smart Reader with Read Range Up to 4-9 cms, Data Read-CSN/Sector, Type-Smart Card (Mifare Classic), Transmit Frequency-13.56 MHz, Card Read Time-0.1 sec, Output Interface-Wiegand Format ( 32 bits), LED Indicator-Bi colour LED, Power supply-12 V DC @ 100mA, Dimensions (in mm)-80W X 83 H X 21 D, Enclosure-ABS Plastic. Cardex / Lenel / Bosch `

89

158598

1782

... More
Supply Installation Testing and Commissioning of Smart I Command Control Software DUO for1000 users with smartCOMMAND,smartESS (Employee Self Service module), SmartACCESS (Advance Access Management Module) and smartAttendance Module (Advance, Atttendance Management Module) Cloud Compatible enterprise level Web based Modular Access Management and Time Attendance software with SQL Database especially designed to cater small, medium and large organizations. Single GUI Plateform with complete modular software with provision to integrate with different application ie: Access Control, VMS, Canteen, Alarm Management, etc. Advance access control management software module with all the access control features i.e.: Time Zone, Access Level, Anti passback, Holiday restrictions, employee black list, etc. Cardex / Lenel / Bosch

1

23161

23161

... More
Supply, installation, testing and commissioning of Client Workstation having Intel Core i5 orginal motherboard, 16 GB RAM, Video graphics card 2 GB Licensed Windows 8 Professional (64 bit) and 1 TB Hard Disk Make: Apple, Dell

1

55587

55587

... More
Supply , Installation , Testing and commissioning of RFID Cards (SC – M1). Cardex / Lenel / Bosch

500

96000

192

... More
`Supply, Installation, testing and commissioning of Air-cooled DX type Hi-wall split air conditioners each comprising an outdoor unit(s) consisting of hermetically sealed compressor,Inverter type suitable for operation on 230V, 50Hz, 1 Phase AC supply, air cooled condenser, condenser fan along with Cooling thermostats etc. with outer casing and indoor fan coil unit consisting of centrifugal fans, fan motor, DX cooling coil, outer casing, filter, control and power panel with remote etc. entire cabling and wiring from indoor to outdoor, insulation (as per the actual pipe length) and with full charge of refrigerant gas (including the increased pipe length, if any) and oil, supports etc. complete as per drawings. The indoor and outdoor units shall be with structural steel supports, angles, rods etc. Logic panel should give audio visual indication till it is deactivated manually.1.5 TR Unit `

1

51763

51763

... More
2.0 TR Unit

2

156060

78030

... More
`Supply , Installation , Testing and commissioning of SmartSWITCH (SIS-ES-PUSH as required. Cardex / Lenel / Bosch `

89

72980

820

... More
`Suplly Installation Testing and Commissioning of EML Lock, Green/red LED indication for lock status, Superior Strength Aluminium Alloy,Solid Stainless Steel Bolt, Operating Voltage-12VDC or 24VDC (Adjustable), Current Draw- 500mA, Holding Force-Up to 600 LBS, Operating Temperature--20C to 60C, Mounting type-Surface, Dimensions:- Magnet-250 X 48.5 X 25 mm (L*W*H), Armature-180 X 38 X 11 mm (L*W*H). Cardex / Lenel / Bosch `

22

64284

2922

... More
`Supplying, installing, testing and commissioning of INLINE FANS suitable for installing in any position in vertical or horizontal ducts. The casing shall be double skin, internally acoustically lined and constructed of galvanised stee 18 SWG. The inline fan shall be with backward/forward curve centrifugal impeller fitted with maintenance free external rotor motor, flexible connections at the discharge and inlet. high efficiency (efficiency-1 / IE-2) TEFC squirrel cage 3 phase 50 Hz, 415 Volt, Class H insulated with IP 54 protection fan motor, V- belt Drive package consisting of Motor Pulley, fan Pully, V- elt, belt Guard and other accessories. quoted price shall be inclusive of DOL starter panel with cabling between starter panel and fan.The incoming power supply to speed regulator / starter panel shall be provided by electrical contractor.The fan shall have low sound level exceeding not more than 40 DBA at three meter distance.The out let velocity shall not exceed 12mtr/sec.Make: Nicotra,Systemair,Airflow. Air Quantity : 1500 CFM (Cabinet Type) Static Pressure : 15 mm wg Motor rating : As Required Duty : Toilet Exhaust Ground Floor`

1

37041

37041

... More
`Suplly Installation Testing and Commissioning of EML Lock, Green/red LED indication for lock status, Superior Strength Aluminium Alloy,Solid Stainless Steel Bolt, Operating Voltage-12VDC or 24VDC (Adjustable), Current Draw- 1000mA, Holding Force-Up to 1200 LBS, Operating Temperature--20C to 60C, Mounting type-Surface, Dimensions:- Magnet-500 X 42 X 28 mm (W*H*D), Armature-160 X 38 X 9 mm (W*H*D). Cardex / Lenel / Bosch `

67

405886

6058

... More
Supply Installation Testing and Commissioning of EML Lock Accessories (U/L Bracket)U/ L bracket for 600lbs electromagnetic lock. Cardex / Lenel / Bosch

89

24119

271

... More
Supply, Installation, Testing and Commissioning of Ceiling/ Floor Mounted Axial flow type exhaust fans (AMCA Certified) complete with MS powder coated / GSS long casing (Motor should be totally accomdated inside the casing),aluminium alloy blades with aerofoil design with adjustable pitch blade. The complete fan assembly along with motor should be UL/CE Listed in accordance with BS EN120101-3:2015 by a notified body. The complete fan shall be able to operate at min. 250 Deg C for 2 Hours temp rating. The high temperature test certificate is to be submitted by fan manufacturer and same clearly indicate the make of motor used during the testing and the same make of motor should be supplied by the fan manufacture at the site. Motor shall be of 415 ± 10% volts, 50 Hz conforming to efficiency grade IE3(for car park-general exhaust fan , ventilation fan/normal case/D.G fan),IE2(for pressurization,additional supply and Smoke exhaust fan ) @ 1450 RPM for General Exhaust and Smoke Exhaust with high temperature resistance confirming to BSEN-12101-3: 2015. Sound level at 3mt distance from fan shall not be more than 80dBA, at room conditions.Capacity shall be as follows and as per detailed technical specifications complete with bird screen,factory fabricated fire retardant silicon coated round flexible duct connections, spring type anti vibration isolators,fan mounting arrangement with sound attenuator(If required). Fan Efficiency to be more than 70%. Fans shall be AMCA certified for air and sound performance. Fan selection should be on air density 1.2 Kg/cum.HVAC Contractor to reconfirm the Fan Motor HP as per manufaturer recommendation.Fan Dia to be selected by the HVAC Contractor as per the Technical specification and site condition.All fans shall have minimum 30 mm Static actual shall be calculated by contractor before purchase.Also all Supply Air fans shall be F class motor and Smoke Exhaust fans shall be H class motor. Make: Nicotra,Systemair,Airflow. Air Quantity : 6500 CFM CLASS F MOTOR

8

212648

26581

... More
Air Quantity :12000 CFM CLASS F MOTOR

3

97842

32614

... More
Air Quantity : 12500 CFM CLASS F MOTOR

4

141548

35387

... More
Air Quantity : 25000 CFM CLASS F MOTOR

4

272984

68246

... More
Air Quantity : 25000 CFM CLASS F MOTOR

4

272984

68246

... More
Air Quantity : 25000 CFM CLASS H MOTOR

4

289288

72322

... More
Air Quantity : 16000 CFM CLASS H MOTOR

7

348159

49737

... More
Air Quantity : 12000 CFM CLASS H MOTOR

17

731867

43051

... More
Air Quantity : 12000 CFM CLASS F MOTOR

7

228298

32614

... More
Air Quantity : 7000 CFM CLASS H MOTOR

2

64576

32288

... More
Air Quantity : 6500 CFM CLASS H MOTOR

1

30087

30087

... More
Air Quantity : 5600 CFM CLASS H MOTOR

4

120348

30087

... More
Air Quantity : 5600 CFM CLASS H MOTOR

3

90261

30087

... More
Air Quantity : 7000 CFM CLASS F MOTOR

1

30821

30821

... More
Air Quantity : 8500 CFM CLASS H MOTOR

10

335110

33511

... More
Air Quantity : 6000 CFM CLASS H MOTOR

1

30087

30087

... More
Air Quantity : 6000 CFM CLASS F MOTOR

1

28619

28619

... More
Supply, installation, testing and commissioning of 8 Core 1 Sq mm Cable (Mtr.)

2200

138600

63

... More
Supply, installation, testing and commissioning of 4 Core 1 Sq mm Cable (Mtr.)

800

43200

54

... More
Supply, installation, testing and commissioning of 3 Core 1 Sq mm Cable (Mtr.)

500

23000

46

... More
Suplly Installation Testing and Commissioning of It is a 12V, 5A Power Supply.12V, 5A Power Supply (For Double leaf Door)

67

62042

926

... More
Supply, fixing and testing of Biomatric Reader suitable for external / Internal environment with Mounting complete as required.

2

26368

13184

... More
Supply, Installation, Testing and Commissioning of 4K 85` interactive professional display, shall feature immersive touchscreen and input and simultaneous multi user writting to provide increased involvement while working. Resolution: 3,840 x 2,160 , Brightness: 350 nits or better, Contrast: 3000:1, or better, Viewing Angle(H/V): 178:178, 6 ms or better Response Time, Built in Speaker (10W x 2), Input: 2 x HDMI, 1x DP, Stereo Mini Jack, RS-232, RJ-45, IR. shall support keyboard and Mouse, 7 ms or better Touch Response Time, Heat Semi-Strengthened Glass, 20 touch, Passive Pen with magnet. WiFi/BT Module Embedded, Document viewer, Video player, Web browser, whiteboarding app, Clock Speed:1.7GHz CPU Quad, Memory: LPDDR4 1.6GHz 64bit 3.0GB, 16GB Storage, Anti glare Film, Shatter proof film, Anti microbial coating . Ability to connect 50 users and upto 4 users present simultaneously from Tabs, mobiles or pcs over network. Shall be supplied with neccesary mounting bracket as required. Panasonic/Sony

2

553022

276511

... More
Supply, Installation, Testing and Commissioning of 65` 4K UHD(3840 X 2160) resolution Android LED display with built in 2.4 Ghz Wifi, 1.1 Ghz Built, in Quad core processor, 2 GB DDR3 RAM, 16 GB Memory, built in Double Core Mali 600 MHz GPU, with HDR 10, Dolby Audio, Built in Wifi and Cromecast, HDMI CEC, HDMI ARC, Built-in Bluetooth Ver.4, 20W built in speakers, HDMI 2.0 X 3, AV X 1, USB 2.0 X 1, RJ45 X 1, Headphone Out x 1, SPDIF Out x 1 complete with mounting and accessories. Panasonic/Sony

2

228050

114025

... More
Supply, Installation, Testing and Commissioning of flush mount cable cubby with connection ports: 1x HDMI, 1x Universal Power Socket, 1x USB complete with standard accessories as per tender specifications. Logic/AMX/Kramer

7

145502

20786

... More
Supply, Installation, Testing and Commissioning of 8x8 HDMI 2.0 matrix switcher with HDCP 2.2 support and capable of handling resolutions up 4K@60Hz 4:4:4 / 8 bit color with static and dynamic HDR output support for each channel. The matrix features advanced independent EDID management control for each HDMI input as well as an Easy EDID analyzer. The analog and digital audio outputs can be set to follow the HDMI video route or can be independently routed either by API or web control interface. Built in re-clocking circuitry ensures the switcher is backwards compatible with sources with older HDMI version chip sets. The matrix switcher can be controlled via front panel buttons, front panel IR, external IR, remote IR, RS232, and Ethernet. The matrix includes a simple IR remote control to allow IR switching. The matrix also features a full command set for RS232 and Ethernet control with third party control systems, plus control via web user interface. AMX/Liberty AV/Kramer

1

235176

235176

... More
Supply, Installation, Testing and Commissioning of 4x1 HDMI 2.0 Auto-switcher, 4K60 4:4:4 / HDR 18G Matrix switcher with audio de-embed, ARC, IR, and RS232 control, Auto-switch or manual switch between four HDMI inputs, 1x HDMI and 1x 3.5mm TRS audio (ARC and audio de-embedding) output Front panel, Supports resolutions up to 4k@60Hz, 4:4:4. 8 bit deep color, Supports HDR formats, HDCP 2.2 compliant, Supports EDID management, Supports CEC pass through control of source / display. AMX/Liberty AV/Kramer

1

27794

27794

... More
Supply, Installation, Testing and Commissioning of HDMI 2.0 HDBaseT Extension Set, Extend HDMI 2.0 signals up to 4K@60Hz / 4:4:4 up to 70m (4K 40m / 1080P 70m), Complete set Includes TX, RX, power supply, and IR flasher/emitter, Extends bi-directional IR. Flexible PoC (Power on either end), Supports HDR10, HDCP 2.2 compliant, Flexible power design (use power supply at TX or RX). AMX/Liberty AV/Kramer

13

491790

37830

... More
Supply, Installation, Testing and Commissioning of USB Tx-Rx set with that Extends USB High-Speed (480 Mbps) up to 100 m (330 ft) and supports isochronous data for use with USB Cameras, Includes transmitter and receiver, Can be powered at either the client or host device, Uses any Cat5e/6/6A twisted pair cabling, Supplies 500mA to USB devices, Can also be used to extend USB 1.1 signals, Transparent USB: Plug and Play (no software drivers needed), USB 2.0 100m extension set with type B on Host and Type A on client w/ isochronous data support. AMX/Liberty AV/Kramer

3

248433

82811

... More
Supply, Installation, Testing and Commissioning of Wireless Presentation Solution, Enables wireless presentation of 4K Wireless Display, App-free, Wireless Touch, Extended Screen support, shall offer Enterprise Management features, up to four Shared screens simultaneously, and annotate in Office 365 apps and share notes to devices or the front-of-room display, Supports display resolutions up to 4K and FUII HD 1080P and UXGA/WUXGA, Provides HDMI / VGA / mini DisplayPort, and analog audio outputs etc. all compJete. AMX/Screen Beam/Kramer

1

133029

133029

... More
`Supply, Installation, Testing and Commissioning of PTZ Camera : USB based : Yes: Zoom : Minimum 20X Optical Zoom: Iris: f=5.57~110mm : F1.6 ~ F3.5:Viewing Angle:3.3° (tele) –54.7° Wide :Sensor:1 /2.8inch or better CMOS sensor: Pixels:2.07 Mega Pixel : Video Format: SDI Video Formats: 1080P60/50/30/25/59.94/29.97 : 1080I60/50/59.94. 720P / 50/ 30 / 25 /59.94/29.97: Minimum illiumination:0.5 Lux : DNR:2D and 3D DNR: White Balance :Auto/Manual/One push 3000K / 3500K / 4000K / 4500K / 5000K / 5500K / 6000K / 6500K /7000K: Electronic Shutter : Auto/Manual: Focus : Should be Auto/Manual/One Push: BLC:ON/Off: WDR : Off/Dynamic level adjustment: Video Adjustment: Brightness, Color, Saturation, Contrast, Sharpness, B/W mode, Gamma curve: SNR : )55 dB: Interface:: USB 3.0 x1, DVi/HDMI x1, , LAN x1, RS232 x1: Video Compression Format:H.265/H.264 : Control Protocol: VISCA/PELCO-D/Pelco-P: Baud Rate : 11520 / 9600 / 4800 / 2400 : LAN Port :Yes: Network Protocol: RTSP/RTMP/ ONVIF, GB/T28181: Pan Rotation: plus 170° Tilt Rotation :-30°~ plus 90° : Pan Control Speed: 0.1~100°/second :Tilt Control Speed : 0.1~45°/second :Preset Speed: Pan: 100°/second, Tilt 45°/second :Preset Number:255 preset OEM Warranty : 1 Years onsite. Panasonic/ATDSC/Lumens`

1

138968

138968

... More
Supply, Installation, Testing and Commissioning of 21.5` Retractable monitor. The Smart retractable monitor with a professional electrically retractable 21.5” widescreen monitor to be integrated in furniture. With a 20° automatic tilt, the monitor has a powder coated steel housing and an up-table cover plate in brushed stainless steel. Should include DVI-I and DVI-D inputs which are HDCP compliant. The Smart monitor integrates a patented single motor system activated through push buttons placed on the cover plate. The monitor works with the AHnet protocol (RS422) through CAT5 loop-through cable, individual addressing and termination switch complete with standard accessories as required. Albiral / Arthur holm / Soltec

1

195980

195980

... More
Supply, installing, testing and commissioning of Jet Fan shall be provided with Dual Speed smoke spill motor with class `H` insulation for smoke extraction.Complete fan alongwith motor shall be suitable for operation on 415±10% volts, 50Hz, 3 phase AC power supply and capable to withstand 300 deg C temperature for a minimum duration of 2 hours. The Impeller of jet fan shall be Airfoil design with High efficiency blades.Jet Fans shall be made in single piece and shall supplied with silencers and fan should be within the silencer to avoid air, sound leakage .Fan shall be AMCA Certified for Air and Sound Performance.The fan shall be tested and certified for (F300) CE/UL Certified for smoke control and exhaust applications in accordance with EN 12101-3:2015 from notified body.Note:The motor make of smoke/exhaust fan shall be same as mentioned on the fire certificate of the fan provided by international independent laboratory under certifying authority. Quantity and location of jet fans will be finalized based on CFD analysis.Make: Nicotra,Systemair,Airflow. 300Ø-400Ø Jet fans as described above (For Basement ventilation)

36

1467648

40768

... More
Supply, Installation, Testing and Commissioning of Annotator with a High performance Graphics engine for the Third party Display or Same OEM Display : Also provides a Third party Touch Display into a Touch Screen(On Screen Menu) for Controlling in room AV Devices : Provides 1 HDMI, 1 CATx Input, 1 HDMI Output : Provides 1 HDMI, 1 CATx Input, 1 HDMI Output : Support video resolution up to 4K and Ultra HD : Supports H.264 streaming videos up to 1080p60/25Mbps : Supports HDCP2.2 : Should support Annotation Functionality : Should be able to have customized Audio Feedback : Built-in Web browser : Should have Multi Touch Support : Should have On screen Multi language Keypad : Should support CEC Control : Memory Should have at least 1GB Ram, 4 GB Flash. Complete with standard accessories as required.

1

203107

203107

... More
SITC of CO/CO2 Sensors with control cable,shall be designed to detect CO/CO2 gas in the air with sensing range between 0-250/300 PPM.

50

32600

652

... More
Supply, Installation, Testing and Commissioning of Control System. Controller with Minimum 4 bidirectional RS232, 4 IR, 4 Relays and 4 GP/IO and 1 Ethernet port to control all the devices in the room. Should have inbuilt or external IR sensor/learner to learn IR commands. The compatible relay controller to control the Projector screen up down should be supplied as a package (may be from same OEM of controller or different). Should have inbuilt processing power and internal storage to store and process the control program. Should be compatible with any (IOS/Android) wireless or wired Touch screen of any size. Additional ports if required can be added with minimum hassle. Should have the flexibility to add as many user interfaces as required. Should have embedded webpage for control port settings. Should have Status LED to check for Control/Connection status. It should support PoE. It should have minimum 5 license each included for both iOS and Android application. Certification: CE, ISO 9001, ISO 14001, OHSAS 18001. Extra component or equipment maybe added to match the complete specs.

1

141106

141106

... More
Supply, Installation, testing and commissioning of Wireless 10` touch Panel. Should support Wi-Fi (802.11a/b/g/n/ac): dual band (2.4GHz and 5GHz): HT80 with MIMO, Bluetooth 4.2 technology, 500 nits brightness. Shall include customized GUI Software compitable with AV controller. Apple or its equivalent

1

53449

53449

... More
Supply, Installation, Testing and Commissioning of Audio Controller : The main unit of the portable digital conference system can support 60 units of Chairman and Delegate microphone. : It support 250 Microphones with extension power unit.: Equipped with four groups or 8p-DIN interface for system connecting.: Modes : Discuss mode, Free mode, FIFO mode (1-9),Limit mode (1-9) : 9 Microphones can be on at a time. First In First Out : The working mode is displayed on LCD screen. : Look At Me – Speaker tracking compatible with camera and processor: Connection: 8PIN x 3 plugs for Microphone : 8 PIN x1 socket for system connection: RCA : 4 x RCA Port: RJ 45 x 1: XLR Port x 1. OSL/ATDSC/Televic

1

135405

135405

... More
Supply, Installation, Testing and Commissioning of Chairman Unit Microphone: Frequency Response: 40Hz-16KHz: Sensitivity: -44 dB:2dB : Length Of Gooseneck: 420mm: Supports Discussion and Video: Chairman With Priority Button: Connectivity : Daisy Chain connection with Loop In Loop Out: OSL/ATDSC/Televic

1

34920

34920

... More
CFD analysis for Basements LUMP SUM

1

200000

200000

... More
Supply, Installation, Testing and Commissioning of Delegate Unit Microphone: Frequency Response: 40Hz-16KHz: Sensitivity: -44 dB:2dB : Length Of Gooseneck: 420mm: Supports Discussion and Video: Connectivity : Daisy Chain connection with Loop In Loop Out: OSL/ATDSC/Televic

18

628560

34920

... More
Supply, Installation, Testing and Commissioning of AEC capable Digital Audio Conferencing Processor with at least 4 Mic/Line inputs and 4 analog outputs, 24 Bit A-D and D-A Convertors: Sampling Rate : 48 kHz: THD : ( 0.002 % or better : Frequency Response 20 Hz - 20 kHz :Dynamic Range ) 115 dB or better, 1 control input ,1 telephone input : RS-232 and Ethernet Port for third party Control and Monitoring: 16x16 or more Bidirectional DANTE Audio Networking ports, Shall include standard Connectivity features like VOIP, POTS, USB Audio etc. inbuilt DSP features like Conference room Routers, Input Equalizers, Router, Band Pass filter, Output Equalizer, Delay, Limiters, gates , Source selectors etc.

1

338219

338219

... More
DUAL SPEED JET FAN ELECTRICAL PANEL(PLC)

4

489216

122304

... More
Supply, Installation, Testing and Commissioning of high impedence Class D Dual zone amplifier with output power of upto 2x120W @ 70/100V. frequency response of 55 Hz - 20 kHz ( plus 0/–3 dB, @ 1 W reference 1 kHz): THD (0.3% at rated power. Channel Separation = –60 dBV (below rated power, 1 kHz), Dynamic range ) 88 dB. Shall include priority override and Fire alarm interface, shall include necessary loudspeaker EQs. Bose/Powersoft/Bosch (Dynacord)

1

88932

88932

... More
Supplying, installing, testing and commissioning of AHU FAN SECTIONS only with double skin construction as outer skin of 0.8mm Pre coated and inner skin of 0.8 mm plain GI with DIDW backward curved, complete with IE-2 squirrel cage induction motor, airfoil centrifugal fan, belt drive and vibrations isolators. Motors shall be suitable for 415 ±10% volts, 50 cycles , 3 phase AC supply and static pressure shall be as indicated. Fan-motor assembly (as whole) shall be statically and dynamically balanced .Fan section shall be for outdoor duty,exposed to sun at terrace and shall be as per specification complete as required.Complete in all respect as required at site.Make: Nicotra,Systemair,Airflow. 5500 CFM 50MM Static

2

132088

66044

... More
6000 CFM 50MM Static

2

132088

66044

... More
Supply, Installation, Testing and Commissioning of full range 2.25-inch or better ceiling mounted music and PA loudspeaker. The loudspeaker shall meet the following performance criteria: Usable Frequency range (-10 dB) of 85Hz to 17kHz or better: Power handling of 64 Watt peak or more: Nominal dispersion of )=130° Conical or better: Sensitivity of 84 dB SPL or better and Peak SPL of 102 dB SPL or better: Nominal impedance of 16 ohms and Integral multi-tap Transformer with selectable tap settings of 2/4/7.5/15W@70V and 100V or better. The loudspeaker shall be enclosed in engineered-plastics with integrated steel backcan and a powder-coated steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applicatons. Bose/EAW/L-Acoustic

8

85720

10715

... More
Supply, Installation, Testing and Commissioning of 16-24-port 1000base-T Gigabit PoE plus Smart Managed Switch. . Should have Network Protocol and Standards Compatibility IEEE 802.3 Ethernet. IEEE 802.3i 10BASE-T. IEEE 802.1x. Access Control Lists (ACLs) L2 / L3 / L4 complete with standard accessories as required. Cisco / Juniper / Ruckus/Extreme/Alcatel

1

37414

37414

... More
Supply, Installation, Testing and Commissioning of Wi-Fi router/Access point for wireless meeting collaboration complete with standard accessories as required. Cisco / Juniper / Ruckus/Extreme/Alcatel

1

6236

6236

... More
`Supply, installation, testing and commissioning of DUAL COIL MICROPROCESSOR BASED PRECISION A/C UNITS as per the specifications complete with air cooled condenser, chilled water coil and variable speed drive for condenser fan, scroll compressor, evaporator coil with hydrophillic coating, EC brushless motor, backward curved/ direct driven fan, first fill of refrigerent, 24 hrs performance test with necessary heat load, multistage electric heater, variable capacity humidifer and vibration isolator. Motor shall be suitable for 415 plus 10% volts, 50 cycles, 3 phase AC supply and external static pressure shall be 25 Pa. Outdoor unit motor should be with IP-54/55 protection and should be weather proof. PAC shall have bottom throw. Each unit shall be complete with powder coated electrical panel and double earthing. The cables should be Cross linked polythene insulated, armoured Copper cabling, with a low smoke and flame sheath (XLPE/SWA/LSF) and all termination between main panel and PAC should have double compression gland. Timers shall be provided in Electrical panel for delayed start of units. It shall be inclusive of copper piping (of required length), drain piping, control and power cabling from MCB to indoor unit and it shall also include MCB, GI tray for supporting the refrigerant pipes (whereever exposed to sun) between indoor and outdoor units. Units shall be equipped with factory integrated 2 way automatic control valve with thermostat. It shall also provided with automatic balancing valve.The unit capacities be actual at room design temperature and delhi ambient conditions, capacties shall sized be after taking deration into account due to copper piping lengths. Condensers should be adequately sized for high ambient temperatures upto 45 Deg C with condensing temperatures not exceeding 56 Deg C.The unit should include INTEGRATOR for giving industry standard (Modbus / Lon Works / Bacnet) output to BMS system. Mapping shall be required for all points displayed on precision unit microprocessor panel. It shall be inclusive of wiring in MS conduit between integrator and individual PAC panel. CHW units shall be capable for delivering 6 TR actual total capacity at below rated chilled water conditions : Chilled Water Inlet to PAHU`s : 6.7 Deg C (44 Deg F),Chilled Water Outlet from PAHU`s : 12.2 Deg C ( 54 Deg F) The air cooled units shall be complete with copper refrigerant piping with nitrile rubber insulation as per specifications.Make: Stuls,Emerson,Bluebox.6 TR Dual Coil (chilled water and DX air cooled) Microprocessor units for Server Room complete as required `

4

3319680

829920

... More
Supply, Installation, Testing and Commissioning of i5 mini PC with 2.3 GHz Core i5 processor, ?8 GB DDR4 Memory, 500 GB SSD Storage, ?Integrated Graphics, Bluetooth, Wi-Fi, 802.11b, 802.11a, 802.11g, shall include ?Windows 10, wireless keyboard and mouce etc.

1

78986

78986

... More
Supplying, fixing, testing and commissioning of( INSULATED CHILLED WATER PIPING) condenser water pipes/ non insulated chilled water pipes of following sizes of MS `C` class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced pipe hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect. Make:Jindal Hissar,Surya,Mukut. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S.Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS above 350 mm dia. 32 mm dia.

230

150650

655

... More
Supply, Installation, Testing and Commissioning of 1.5 Sq. mm (48/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath.

100

12400

124

... More
Supply, Installation, Testing and Commissioning of 18 AWG (24/0.20mm) x 2 core ATC copper conductor, PE insulated, core twisted in a circular form, Inner sheathed with moisture Proof Polymer, braid shielded (80%) with ATC copper, outer Jacketed with Matt finish Rugged Flexible PVC.

20

2480

124

... More
Supplying, fixing, testing and commissioning of( INSULATED CHILLED WATER PIPING) condenser water pipes/ non insulated chilled water pipes of following sizes of MS `C` class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced pipe hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect. Make:Jindal Hissar,Surya,Mukut. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S.Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS above 25 mm dia.

250

120000

480

... More
Supply, Installation, Testing and Commissioning of Category 6A F/UTP EN Series 23 AWG 4 Pair Shielded Cable. Solid annealed bare copper conductors, High density polyethylene insulation, 4 pairs twisted in varying lays and cabled, Flame rated PVC jacket, TIA/EIA-568-C Category 6A, NEC CMR, CEC CMR FT4, RoHS compliant.

150

22800

152

... More
Supply, Installation, Testing and Commissioning of 6 ft Premium High Speed HDMI Cables with Ethernet, Full 18 Gig HDMI 2.0 4K@60Hz and HDR Certified by HDMI ATC. Should Support Ethernet, ARC, CEC, and all HDMI Audio formats. NEC CM, CEC CMG FT4, RoHS/REACH Compliant, Complete with standard accessories as required.

20

36580

1829

... More
Supply, Installation, Testing and Commissioning of 10 ft Premium High Speed HDMI Cables with Ethernet, Full 18 Gig HDMI 2.0 4K@60Hz and HDR Certified by HDMI ATC. Should Support Ethernet, ARC, CEC, and all HDMI Audio formats. NEC CM, CEC CMG FT4, RoHS/REACH Compliant, Complete with standard accessories as required.

10

20790

2079

... More
Supplying, fixing, testing and commissioning of condenser water pipes/ non insulated chilled water pipes of following sizes of MS `C` class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:- The Pipes size 150 mm and below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Make:Jindal Hissar,Surya,Mukut. 350 mm dia.

150

1048350

6989

... More
Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. Make: Advance,LandT,Audco. 350 mm dia.

3

80202

26734

... More
Supply, Installation, Testing and Commissioning of USB Patch Cord, bulk connectors such as XLR, RJ-45, AUX etc as per requirement Make:

1

41572

41572

... More
Supply, Installation, testing and commissioning of 19` 24U AV rack complete with standard accessories as per tender specification.

1

46560

46560

... More
Supplying, fixing, testing and commissioning of BALANCING VALVE flanged end and PN 16 pressure rating as specified.Insulation on Butterfly /balancing/Non return/Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required,complete.Make: Advance,LandT,Audco. 32 mm dia.

15

63105

4207

... More
4kg capacity Novec 1230 or equivalent ref Nfpa 2001 Fk-5-1-12 with UL approved non ferrous Seamless Cylinder, DLP Assembly with automatic valve, push in connector for tube, UL approved 4 Kilogram Novec 1230 or equivalent ref Nfpa 2001 Fk-5-1-12 , mounting bracket, End of Line adopter and UL approved low pressure switch and UL approved Pressure guage for monitoring system activation.

6

276510

46085

... More
UL Listed Heat detection Tube, 4mm ID, 6mm OD, detection temprature less than 175 Deg celcius, Water Absorbtion = 1.5% @ 20oC and 50% RH as tested per ISO62 with fittings and supports warantee of 5 years.

200

175800

879

... More
Supplying, fixing, testing and commissioning of BALANCING VALVE flanged end and PN 16 pressure rating as specified.Insulation on Butterfly /balancing/Non return/Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required,complete.Make: Advance,LandT,Audco. 25 mm dia.

1

4008

4008

... More
Master Control Unit for controlling each system, complete with Audio Visual Monitoring Panel Micro Controller Based design with AC power ON, system ON, system discharge, pressure healthy, battery low indication/LED, Electrical Buzzer including all necessary accessories plus electrical wiring to make each entire system functional for notification.

2

18244

9122

... More
Supplying, fixing, testing and commissioning of STRAINER flanged end and PN 16pressure rating as specified.Insulation on Butterfly /balancing/Non return/Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required,complete.Make: Advance,LandT,Audco. 32 mm dia.

13

54691

4207

... More
FIRE SUPRESSION SYSTEM - Supply, Installation, Testing and Commissioning of CCOE Approved Seamless Gas Supression Cylinder with valve assembly. Make: Honeywell, Ceasfire 80 ltr

2

244738

122369

... More
Supplying, fixing, testing and commissioning of STRAINER flanged end and PN 16pressure rating as specified.Insulation on Butterfly /balancing/Non return/Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required,complete.Make: Advance,LandT,Audco. 25 mm dia.

1

4008

4008

... More
`Supply, Installation, Testing and Commissioning of clean agent Fire Protection Fluid Extinguishing Agent shall be mentioned in NFPA 2001 edtion 2022 and shall be: The agent shall not contain any Hydro fluorocarbons (HFC). The ozone depletion potential should be zero. The Global warming potential should be equal to or less than 1 The Extinguishing Agent should be UL Listed/ FM approved. The extinguishing agent should be filled in an PESO approved filling station.Ceasefire/Honeywell`

83

227171

2737

... More
`Providing and fixing in position the following Ball Valves with Strainer duly insulated as per specifications and drawings. Ball valve shall be screwed type brass/bronze lever operated, quarter turn ball valve (screwed type) of full flow with bronze /forged brass hard chrome plated ball with setting and gland of superior quality of preferably PN 16 rating.Make: Advance,LandT,Audco.32 mm dia`

38

71668

1886

... More
`Supply, Installation, Testing and Commissioning of of `Master Cylinder Kit complete comprises of a. Electric Control Head operated electrically from the detection and control system or locally with a manual actuator, complete with cylinder supervisory switch. b. Wire Braided Flexible Rubber Hose with Elbow and connectors complete assembly to Connect Cylinder Assembly Discharge outlet with Discharge Pipe or Discharge Manifold. Ceasefire/Honeywell`

2

125366

62683

... More
`Providing and fixing in position the following Ball Valves with Strainer duly insulated as per specifications and drawings. Ball valve shall be screwed type brass/bronze lever operated, quarter turn ball valve (screwed type) of full flow with bronze /forged brass hard chrome plated ball with setting and gland of superior quality of preferably PN 16 rating.Make: Advance,LandT,Audco.25 mm dia`

40

51800

1295

... More
Supply, Installation, Testing and Commissioning of Nozzles, 360 Deg / 180 Deg Throw, selection as per approved hydraulic flow calculations. Ceasefire/Honeywell

10

137780

13778

... More
`Providing and fixing in position the following Ball Valves with Strainer duly insulated as per specifications and drawings. Ball valve shall be screwed type brass/bronze lever operated, quarter turn ball valve (screwed type) of full flow with bronze /forged brass hard chrome plated ball with setting and gland of superior quality of preferably PN 16 rating.Make: Advance,LandT,Audco.20 mm dia`

35

39060

1116

... More
Supply, Installation, Testing and Commissioning of warning Sign. Ceasefire/Honeywell

2

5090

2545

... More
`Providing and fixing in position the following Ball Valves without strainer, duly insulated as per specifications and drawings. Ball valve shall be screwed type brass/bronze lever operated, quarter turn ball valve (screwed type) of full flow with bronze /forged brass hard chrome plated ball with setting and gland of superior quality of preferably PN 16 rating.Make: Advance,LandT,Audco.25 mm dia`

4

3592

898

... More
Supply, Installation, Testing and Commissioning of GAS Release Control Panel, Manual release switch, manual abort Switch , Pre and Post alarm sounder cum strobe, cable. Ceasefire/Honeywell

2

215100

107550

... More
`Providing and fixing in position the following Ball Valves without strainer, duly insulated as per specifications and drawings. Ball valve shall be screwed type brass/bronze lever operated, quarter turn ball valve (screwed type) of full flow with bronze /forged brass hard chrome plated ball with setting and gland of superior quality of preferably PN 16 rating.Make: Advance,LandT,Audco.20 mm dia`

38

29602

779

... More
Supply, Installation, Testing and Commissioning of Piping, fittings and supports, etc. Pipe (S) : M.S. Seamless To ASTM A-106, SCH. 40. Ceasefire/Honeywell

1

42759

42759

... More
Supplying, fixing, testing and commissioning of NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified.Make: Advance,LandT,Audco. 250 mm dia

3

43377

14459

... More
Design, manufacture , supply, installation, testing and commissioning of 630 Amps.,11 KV, 18.37 KA breaking capacity (350 MVA) VCB panel board fabricated out of 2mm sheet steel, dust tight, vermin proof, totally enclosed and fully interlocked, IP 4X protection, cubical type, floor mounting, extensible on both sides, suitable for indoor operation at 11 KV, 3 phase, 50 Hz, AC supply complete with rack in - rack out mechanisms, switches, plugs and sockets and all required accessories, cable termation box at back with bottom cable entry for cable size upto 3 core 240 sqmm. armoured cable for each section, internal copper wiring, earth terminals, painting etc. as required , as per specifications and SLD with the following equipped switch gears and accessories complete in all respect. INCOMERS - 1 NO. Each feeder shall consist of : 630 Amps., 11KV horizontal draw out type VCB with motorized spring charge mechanism and required safty switchgears complete. 11 KV / volt PT of class 1.0 accurancy and 100 VA burden. Set of dual core dual ratio CTs of 300/5 Amps. of 15 VA burden and accurancy class 0.5 for metering and class 5 P 10 for protection. 96mm x 96mm type 100 Amp Digital Type ammeter with inbuilt ASS 96mm x 96mm type Digital Type Voltmeter protected by HRC fuses / MCBs with inbuilt VSS Digital tri-vector Meter (Smart Controller) having 30 days memory Class -1.0 with MDI and RS 485 port. Frequency meter Micro processor based feeder protection numerical relay with adjustable O/L, E/F and short circuit protection with communication port. (O/L Setting 50-200% and E/F setting 20-80%) Set of LED indication lamp protected by MCB for RYB Phases, trip, ON and OFF, spring charge, auto trip / trip healthy of breaker complete. Annunciator window (with minimum 6 window) for feeder alarm / tripping annunciations with electronic hooter. Master trip and trip circuit supervision relay, Antipumping Relay, Auxiliary Relay complete. Limit switch for tests and service position, circuit breaker control switch (T/N/C) Trip coil and closup operation at 24 Volts DC through battery bank power pack BUSBARS 630A TP Copper bus bar 11 KV MAIN HT PANEL BOARD(SINGLE BREAKER)

1

569262

569262

... More
Supplying, fixing, testing and commissioning of BALANCING VALVE flanged end and PN 16 pressure rating as specified.Make: Advance,LandT,Audco. 250 mm dia.

3

196419

65473

... More
11KV HT PANEL BOARD (THREE BREAKER) (One incomers, and Two out goings) Design, manufacture , supply, installation, testing and commissioning of 630Amps., 11 KV, 18.37 KA breaking capacity (350 MVA) VCB panel board fabricated out of 2mm sheet steel, dust tight, vermin proof, totally enclosed and fully interlocked , IP 4X protection, cubical type, floor mounting, extensible on both sides, suitable for indoor operation at 11 KV, 3 phase, 50 Hz, AC supply complete with rack in - rack out mechanisms, switches, plugs and sockets and all required accessories, cable termation box at back with bottom cable entry for cable size upto 3 core 240 Sq.mm. armoured cable for each section, internal copper wiring, earth terminals, painting etc. as required , as per Technincal specifications and SLD with the following equipped switch gears and accessories complete in all respect. Incomers - 1 Set. Each feeder shall consist of : `630 Amps.,11KV horizontal draw out type VCB with motorized spring charge mechanism and required safty switchgears complete.` 11 KV / 110 volt PT of class 1.0 accurancy and 100 VA burden. Set of dual core dual ratio CTs of 300/150/5/5 Amps. of 15 VA burden and accurancy class 1.0 for metering and class 5 P 10 for protection. 96mm x 96mm type 630 Amp ammeter Digital type with ASS 96mm x 96mm square Digital type Voltmeter protected by HRC fuses / MCBs with inbuilt VSS Digital Trivector Meter (Smart Controller) having 30 days memory, Class 0.5 with MDI and RS 485 port. Frequency meter Set of LED indication lamp protected by MCB for RYB Phases, trip, ON and OFF, spring charge, auto trip / trip healthy of breaker complete. Master trip and trip circuit supervision relay, Antipumping Relay, Auxiliary Relay etc. Limit Switch for tests and service position, circuit breaker control switch (T/N/C). Trip coil operation at 24 Volts DC through battery bank. Limit switch for tests and service position, circuit breaker control switch (T/N/C) Trip / Closing coil operation at 24 Volts DC through battery bank Busbar 630A TP Copper bus bar OUT GOING - 2 Sets Each feeder shall consist of : 630 Amps.,11KV horizontal draw out type VCB with motorized spring charge mechanism and required safty switchgears complete. Set of dual core CTs of 150/ 5 Amps.CT for 2000 KVA TRF, of 15 VA burden and accurancy class 1.0 for metering and class 5 P 10 for protection. 96mm x 96mm square Digital Ammeter with inbuilt ASS Micro processor based feeder protection numerical relay with adjustable O/L, E/F and short circuit protection with communication port. (O/L Setting 50-200% and E/F setting 20-80%) Set of LED indication lamp protected by MCB for RYB Phases, trip, ON and OFF, spring charge, auto trip / trip healthy of breaker complete. Annunciator window (with minimum 6 window) for feeder alarm / tripping annunciations with electronic hooter. Master trip and trip circuit supervision relay, Antipumping Relay, Auxiliary Relay complete. Limit switch for tests and service position, circuit breaker control switch (T/N/C) Trip and closed coil operation at 24 Volts DC through Ppower pack 11KV HT PANEL BOARD (THREE BREAKER)

1

1549890

1549890

... More
EXHAUST PIPING Supplying and fixing exhaust gas piping of 200mm dia. Welded black MS, B class pipe confirming to IS:3589 cut to required lengthsand installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/rockwool, 50mm thick wiremesh and aluminium clading etc, as required as per specification.

500

2493000

4986

... More
Supplying, fixing, testing and commissioning of STRAINER flanged end and PN 16pressure rating as specified. Make: Advance,LandT,Audco. 250 mm dia.

3

110172

36724

... More
MS  STRUCTURE  Fabrication, supply and erection of MS support for fixing of exhaust piping and MS structure including Angle / chanels / flats / beam as per approved drawings for supporting of DG exhaust stack from ground. floor level and above terrace level complete in all respect.

5000

445000

89

... More
Providing, fixing, testing and commissioning of resilient rubber lined double arch vibration eliminators(bellows) to provide relief from stresses at pipe flanges. It should be complete as per manufacturer`s specifications and as directed by Engineer- in-charge.(PN 16 rating)250 mm dia.

12

171300

14275

... More
Providing and fixing in position following size of heavy duty stainless steel flanged expansion bellows with G.I. nut bolt washers for DG fume piping complete with GI nut bolt washers etc. complete as required. (for DG Sets) 200 mm dia

8

28496

3562

... More
Providing, fixing, testing and commissioning of resilient rubber lined double arch vibration eliminators(bellows) to provide relief from stresses at pipe flanges. It should be complete as per manufacturer`s specifications and as directed by Engineer- in-charge.(PN 16 rating)200 mm dia.

12

122316

10193

... More
Supply, installation, testing and commissioning of 990 litres capacity day oil storage tank fabricated from 6 mm thick MS plates. Tank shall include 450 mm ID manhole cover, level indicator with duly calibrated scale and flanged connection for inlet, outlet, overflow drain and probe provision for level controller and breather.

4

189952

47488

... More
Providing, fixing, testing and commissioning of resilient rubber lined double arch vibration eliminators(bellows) to provide relief from stresses at pipe flanges. It should be complete as per manufacturer`s specifications and as directed by Engineer- in-charge.(PN 16 rating)150 mm dia.

12

87684

7307

... More
Oil Piping Supply, installation, testing and commissioning of the following MS class ‘C’ pipes cut to required lengths and installed with all welded joints. Providing the necessary fittings like elbows, tees and reducers, sockets, hot dip galvanized supports and accessories including ceiling Hanger, Hardware complete as per site requirement. 20 mm dia MS pipes(For 500 KVA DG Set)

100

23700

237

... More
Providing and fixing Auto air vents (Brass MOC) of following size 20 mm dia

538

308812

574

... More
Supply, installation, testing and commissioning of the following MS class ‘C’ pipes cut to required lengths and installed with all welded joints. Providing the necessary fittings like elbows, tees and reducers, sockets, hot dip galvanized supports and accessories including ceiling Hanger, Hardware complete as per site requirement. Providing 20 mm dia. ball valves (For 500 KVA DG Set)

8

3800

475

... More
Supplying, installation, testing and commissioning of Pot strainer. Pot Strainers body shall be fabricated out of MS plate IS 226. Thickness of sheet shall be as per size of the strainer chamfered pipes with flanges shall be provided at inlet /outlet connections of the strainer. A powerful magnet shall be provided in the body to arrest MS particles. Filter element of Pot Strainer shall be of non magnetic 18 gauge SS sheet properly reinforced to avoid damage of the element..A set of MS flanges with tongue and groove arrangement and neoprene rubber gasket shall be provided on the top cover and Pot Strainer flange with sufficient bolts and nuts to make the joint water light. The Pot strainer body shall be properly de-rusted and epoxy coated from inside and outside. Make : Emerald, Anergy, Rapidcool,Activeline.Connection Size 350 mm dia (for condenser water line)

1

54600

54600

... More
MAIN CHANGEOVER PANEL Supply, installation, testing and commissioning of cubical type LT panel suitable for 415V, 3 phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning and finishing complete with 7 tank process for power coating in approved shade, having 3600 Amp capacity extensible type TPN aluminium alloy busbar of high conductivity, DMC/SMC bus bar of high conductivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 second, bottom base channel of MS secton not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have common copper earth bar of size 25 mm x 5 mm at the rear with 2 nos. earth stud, solid connections from main busbar to switch gears with required size of Al. bus bars and control wiring with 2.5sqmm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. Main L.T. Panel shall conform to `Form 3b` construction. (All software and hardware required to achieve the operation of Main LT Panel including interlocking shall deemed to be included in the quoted rate of Main LT Panel INCOMER FROM TRANSFORMER 2 Nos. of 1600 A 4P electrically operated Drawout type ACB with Ics=Icu=Icw 50KA having Mircroprocessor based releases for O/L, S/C and E/F. 2 Sets - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 2 Sets - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 2 Sets indicating LED lamps for ACB On/Off/ Trip with protective SP MCB`s. 2 Sets of CTs of the ratio 1600/5A with class 0.5 Accuracy for Metering, burden 15 VA 2 No. 1600/5A , 15 VA, 5P10 CT`s for Protection 2 No. Under Voltage relay 2 No. Negative Phase protection Relay 2 No. over Voltage relay 2 No. Over Current Relay and earth fault relay 2 No. Direction Power Relay 2 No. Over and under frequency relay INCOMER FROM DG SYNCHRONISING PANEL 2 Nos. of 1600 A, 4P ACB with (50KA) having Mircroprocessor based releases for O/L, S/C and E/F protection. 2 Sets - Digital Multifunction Meter (showing harmonics along with all other electrical parameters such as Voltage, current, Hz, KW, KVA, KVAR, KWh, PF.) with RS 485 port with matching cast resin CT`s 2 Sets of Red, Yellow and blue LED type 22.5mm dia. Indicating lamps with protective SP MCB`s. 2 Set- of ON/OFF/Trip indicating lamps. BUS COUPLER: 1 Nos. of 1600 A, 4P electrically operated Drawout type ACB with Ics=Ics=50KA having Mircroprocessor based releases for O/L, S/C and E/F protection. 3 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. Interlocking: Electrical Interlocking through advance contacts / contactors in MCCB/ACB`s (Incomers and Bus couplers) should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed. Breaker Accessories 24 V DC Shunt trip Coil-1 Set 240 V AC under Voltage release-1 set Auto - manual/ test selector switch-1 set Breaker control switch-1 set Auxilliary contacts required for necessary interlocking of breakers BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 2000 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS-Bus Section-1 1 No. 1600A 4P ACB (50 KA) OUTGOINGS-Bus Section-2 1 No. 1600A 4P ACB (50 KA) The Switchboard with Logic control panel shall be complete with all interconnections, risers, internal wiring, labels, control/circuit fuses etc. complete as required. Note: Incomer from LT Supply, D.G. set and Bus coupler shall be electrically and mechanically interlocked.

1

1038800

1038800

... More
Supplying, installation, testing and commissioning of Pot strainer. Pot Strainers body shall be fabricated out of MS plate IS 226. Thickness of sheet shall be as per size of the strainer chamfered pipes with flanges shall be provided at inlet /outlet connections of the strainer. A powerful magnet shall be provided in the body to arrest MS particles. Filter element of Pot Strainer shall be of non magnetic 18 gauge SS sheet properly reinforced to avoid damage of the element..A set of MS flanges with tongue and groove arrangement and neoprene rubber gasket shall be provided on the top cover and Pot Strainer flange with sufficient bolts and nuts to make the joint water light. The Pot strainer body shall be properly de-rusted and epoxy coated from inside and outside. Make : Emerald, Anergy, Rapidcool,Activeline.Connection Size 250 mm dia (for chilled water line)

1

40448

40448

... More
D.G. SYNCHRONISATION PANEL INCOMER FROM DG SETS 4 Nos. of 800 A 4P electrically operated Drawout type ACB with Ics=Icu=Icw 50KA having Mircroprocessor based releases for O/L, S/C and E/F. 4 Sets - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 4 Sets indicating LED lamps for ACB On/Off/ Trip with protective SP MCB`s. 4 Sets of CTs of the ratio 1600/5A with class 0.5 Accuracy for Metering, burden 15 VA 4 No. 1600/5A , 15 VA, 5P10 CT`s for Protection 4 Sets 3 phase and neutral, neutral to earth (minimum 10 mode) surge suppressor for 50 KA along with necessary fuses. 4 No. Under Voltage relay (59) 4 No. Over and under frequency relay BUS COUPLER: 1 Nos. of 1600 A, 4P electrically operated Drawout type ACB with Ics=Ics=50KA having Mircroprocessor based releases for O/L, S/C and E/F protection. 3 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. Interlocking: Electrical Interlocking through advance contacts / contactors in MCCB/ACB`s (Incomers and Bus couplers) should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed. Breaker Accessories 24 V DC Shunt trip Coil-1 Set 240 V AC under Voltage release-1 set Auto - manual/ test selector switch-1 set Breaker control switch-1 set Auxilliary contacts required for necessary interlocking of breakers BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 2000 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS-Bus Section-1 1 No. 1600A 4P ACB (50 KA) OUTGOINGS-Bus Section-2 1 No. 1600A 4P ACB (50 KA) PLC FEEDER- AUTO ON/OFF AND AUTO LOAD MANAGEMENT and AUTO SYNCH : `Hardware using PLCs for Monitoring of all Electrical Software and for operations, controlling and interlocking Parameters of 4 Nos. DG with Window based software and Engineering and Software Development. Required Aux. Relays, Push Buttons and Indication lamps, 1KVA UPS for Black start and maintenance free Batteries, Power monitors, Programmable Logic controller, Annunciator and status Fascia, MIMIC with LED circuit etc as required completing the system.(As per SLD). ` The Switchboard with Logic control panel shall be complete with all interconnections, risers, internal wiring, labels, control/circuit fuses etc. complete as required. Note: Incomer from D.G. set and Bus coupler shall be electrically and mechanically interlocked. DG Synchronisation Panel as described above

1

1616373

1616373

... More
Supplying, installation, testing and commissioning of Pot strainer. Pot Strainers body shall be fabricated out of MS plate IS 226. Thickness of sheet shall be as per size of the strainer chamfered pipes with flanges shall be provided at inlet /outlet connections of the strainer. A powerful magnet shall be provided in the body to arrest MS particles. Filter element of Pot Strainer shall be of non magnetic 18 gauge SS sheet properly reinforced to avoid damage of the element..A set of MS flanges with tongue and groove arrangement and neoprene rubber gasket shall be provided on the top cover and Pot Strainer flange with sufficient bolts and nuts to make the joint water light. The Pot strainer body shall be properly de-rusted and epoxy coated from inside and outside. Make : Emerald, Anergy, Rapidcool,Activeline.Connection Size 200 mm dia (for Hot water line)

1

40448

40448

... More
Capacitor Panel (350 kVAR) INCOMER 1 No. 630A TP MCCB (36KA) having Mircroprocessor based releases for O/L, S/C and E/F protection. METERING and INDICATION 1 set of phase indicating lamps 1 No. 11 step-Microprocessor APFC controller/Relay(Dual source purpose) shall continuously monitoring all three phases and LCD displays for various Electrical Parameters like voltage, input current, capacitive current, KVA demand, KW, Power Factor, self diagnostic error code indication with printout facility of the above with RS 232/RS 485 port. Controller should mounted on the front side of the panel. Capacitor bank having 3 phase MPP based mix dieelectric low loss ISI marked power capacitor. BUS-BAR 1 Set of 800A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 4 Nos.of 100A TP MCCB (25 KA) each with 4 Nos. 50 KVAR MPP Heavy Duty capacitor Bank each with capacitor duty contactor. 4 Nos.of 63A TP MCCB (25 KA) each with 4 Nos. 25KVAR MPP Heavy Duty capacitor Bank each with capacitor duty contactor. 2 Nos.of 40A TP MCCB (25 KA) each with 2 Nos. 20KVAR MPP Heavy Duty capacitor Bank each with capacitor duty contactor. 1 Nos.of 32A TP MCB (10 KA) each with 1 Nos. 10 KVAR MPP Heavy Duty capacitor Bank each with capacitor duty contactor. Capacitor Panel (350 kVAR) as described above

2

889212

444606

... More
MAIN LT PANEL INCOMER FROM CHANGE OVER PANEL 2 Nos. of 1600 A 4P electrically operated Drawout type ACB with Ics=Icu=Icw 50KA having Mircroprocessor based releases for O/L, S/C and E/F. 2 Sets - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 2 Sets indicating LED lamps for ACB On/Off/ Trip with protective SP MCB`s. 2 Sets of CTs of the ratio 1600/5A with class 0.5 Accuracy for Metering, burden 15 VA 2 Sets of CTs of the ratio 1600/5A for APFC Relay, Burden 15 VA BUS COUPLER: 1 Nos. of 1600 A, 4P electrically operated Drawout type ACB with Ics=Ics=50KA having Mircroprocessor based releases for O/L, S/C and E/F protection. 3 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. Interlocking: Electrical Interlocking through advance contacts / contactors in MCCB/ACB`s (Incomers and Bus couplers) should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed. Breaker Accessories 24 V DC Shunt trip Coil-1 Set 240 V AC under Voltage release-1 set Auto - manual/ test selector switch-1 set Breaker control switch-1 set Auxilliary contacts required for necessary interlocking of breakers OUTGOINGS-Bus Section-1 1 No. 800A 4P ACB (50 KA) FOR HVAC PANEL SUPPLY 1 1 No. 630A TP MCCB (36 KA) FOR CAPACITOR PANEL-1 1 No. 630A 4P MCCB (36 KA) FOR RISING MAIN-1 1 Nos. 125A 4P MCCB (25KA) FOR MAIN LIFT PANEL 1 Nos. 100A 4P MCCB (25KA) for PLUMBING PANEL 1 Nos. 125A 4P MCCB (25KA) FOR VENTILATION PANEL BASEMENT-2 1 Nos. 125A 4P MCCB (25KA) FOR VENTILATION PANEL-1 TERRACE 1 Nos. 63A 4P MCCB (16KA) for EXTERNAL LIGHTING FEEDER 1 Nos. 160A 4P MCCB (25KA) for BASEMENT-2 MDB-B2.1 1 Nos. 160A 4P MCCB (25KA) for BASEMENT-1 MDB-B1.1 1 Nos. 400A 4P MCCB (36KA) for SPARE 1 Nos. 250A 4P MCCB (25KA) for SPARE 1 Nos. 100A 4P MCCB (25KA) for SPARE OUTGOINGS-Bus Section-2 1 No. 630A TP MCCB (50 KA) FOR CAPACITOR PANEL-2 1 No. 630A 4P MCCB (36 KA) FOR RISING MAIN-2 1 No. 800A 4P ACB (50 KA) FOR HVAC PANEL SUPPLY 2 1 Nos. 250A 4P MCCB (25KA) FORUPS INPUT PANEL 1 Nos. 100A 4P MCCB (25KA) for STP PANEL 1 Nos. 100A 4P MCCB (25KA) for VENTILATION PANEL BASEMENT-1 1 Nos. 125A 4P MCCB (25KA) FOR VENTILATION PANEL-2 TERRACE 1 Nos. 250A 4P MCCB (25KA) FOR FIRE FIGHTING PANEL 1 Nos. 160A 4P MCCB (25KA) for BASEMENT-2 MDB-B2.2 1 Nos. 160A 4P MCCB (25KA) for BASEMENT-1 MDB-B1.2 1 Nos. 300A 4P MCCB (36KA) FOR VENTILATION PANEL-3 TERRACE ATRIUM 1 Nos. 400A 4P MCCB (36KA) for SPARE 1 Nos. 250A 4P MCCB (25KA) for SPARE 1 Nos. 100A 4P MCCB (25KA) for SPARE The Switchboard with Logic control panel shall be complete with all interconnections, risers, internal wiring, labels, control/circuit fuses etc. complete as required. Note: Incomer and Bus coupler shall be electrically and mechanically interlocked. Main LT Panel as described above

1

2202256

2202256

... More
Electrical Panel Basement-2-MDB B2.1 INCOMER 1 No. of 160A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 160/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 200 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 1 Nos. 160A 4P MCCB (25KA) for Car`s Fast Charging 2 Nos. 63A 4P MCCB (16KA) for Car Charging 2 Nos. 63A 4P MCB (10KA) for LDB-B2.1.1 and LDB-B2.1.2 1 Nos. 100A 4P MCCB (25KA) for Spare 1 Nos. 63A 4P MCB (10KA) for Spare Electrical Panel Basement-2 MDB B2.1 as described above

1

124656

124656

... More
Providing and fixing(with wall/floor chasing and rifiling) in position the heavy duty,ISI markerd pvc pipe with all fittings and acessaries ,duly insulated with 6 mm thick alu. Laminated nitrile rubber pre formed pipe section as per specifications. 25 mm dia

25

2625

105

... More
Electrical Panel Basement-2-MDB B2.2 INCOMER 1 No. of 160A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 160/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 200 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 1 Nos. 160A 4P MCCB (25KA) for Car`s Fast Charging 2 Nos. 63A 4P MCCB (16KA) for Car Charging 2 Nos. 63A 4P MCB (10KA) for LDB-B2.2.1 and LDB-B2.2.2 1 Nos. 100A 4P MCCB (25KA) for Spare 1 Nos. 63A 4P MCB (10KA) for Spare Electrical Panel Basement-2 MDB B2.2 as described above

1

124656

124656

... More
Providing and fixing(with wall/floor chasing and rifiling) in position the heavy duty,ISI markerd pvc pipe with all fittings and acessaries ,duly insulated with 6 mm thick alu. Laminated nitrile rubber pre formed pipe section as per specifications. 32 mm dia

25

3275

131

... More
Providing and fixing(with wall/floor chasing and rifiling) in position the heavy duty,ISI markerd pvc pipe with all fittings and acessaries ,duly insulated with 6 mm thick alu. Laminated nitrile rubber pre formed pipe section as per specifications. 40 mm dia

100

15700

157

... More
Electrical Panel Basement-1-MDB B1.1 INCOMER 1 No. of 160A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 160/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 200 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 1 Nos. 160A 4P MCCB (25KA) for Car`s Fast Charging 2 Nos. 63A 4P MCCB (16KA) for Car Charging 2 Nos. 63A 4P MCB (10KA) for LDB-B1.1.1 and LDB-B1.1.2 1 Nos. 100A 4P MCCB (25KA) for Spare 1 Nos. 63A 4P MCB (10KA) for Spare Electrical Panel Basement-1 MDB B1.1 as described above

1

153742

153742

... More
Electrical Panel Basement-1-MDB B1.2 INCOMER 1 No. of 160A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 160/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 200 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 1 Nos. 160A 4P MCCB (25KA) for Car`s Fast Charging 2 Nos. 63A 4P MCCB (16KA) for Car Charging 2 Nos. 63A 4P MCB (10KA) for LDB-B2.2.1 and LDB-B2.2.2 1 Nos. 100A 4P MCCB (25KA) for Spare 1 Nos. 63A 4P MCB (10KA) for Spare Electrical Panel Basement-1 MDB B1.2 as described above

1

124656

124656

... More
Electrical Panel Ground-MDB G-1 INCOMER 1 No. of 125A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 125/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 160 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 1 Nos. 40A 4P MCCB (16KA) for AHU 9 Nos. 32A 4P MCCB (16KA) for AHU`s 2 Nos. 40A 4P MCB (10KA) for LDB G1.1 and LDB G1.3 2 Nos. 63A 4P MCB (10KA) for PDB G1.2 and PDB G1.4 2 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 1 Nos. 32A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel Ground MDB G-1 as described above

1

232691

232691

... More
Electrical Panel Ground-MDB G-2 INCOMER 1 No. of 100A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 100/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 120 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 3 Nos. 40A 4P MCCB (16KA) for AHU 5 Nos. 32A 4P MCCB (16KA) for AHU`s 2 Nos. 40A 4P MCB (10KA) for LDB G2.1 and LDB G2.3 2 Nos. 63A 4P MCB (10KA) for PDB G2.2 and PDB G2.4 2 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 1 Nos. 32A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel Ground -MDB G-2 as described above

1

153742

153742

... More
Electrical Panel First-MDB 1.1 INCOMER 1 No. of 125A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 125/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 160 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 2 Nos. 40A 4P MCCB (16KA) for AHU`s 5 Nos. 32A 4P MCCB (16KA) for AHU`s 2 Nos. 40A 4P MCB (10KA) for LDB 1.1.1 and LDB 1.1.3 2 Nos. 63A 4P MCB (10KA) for PDB 1.1.2 and PDB 1.1.4 2 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 1 Nos. 32A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel First MDB 1.1 as described above

1

232691

232691

... More
Electrical Panel First-MDB 1.2 INCOMER 1 No. of 100A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 100/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 1250 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 3 Nos. 40A 4P MCCB (16KA) for AHU`s 4 Nos. 32A 4P MCCB (16KA) for AHU`s 2 Nos. 40A 4P MCB (10KA) for LDB 1.2.1 and LDB 1.2.3 2 Nos. 63A 4P MCB (10KA) for PDB 1.2.2 and PDB 1.2.4 2 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 1 Nos. 32A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel First MDB 1.2 as described above

1

153742

153742

... More
Electrical Panel Second-MDB 2.1 INCOMER 1 No. of 125A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 125/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 160 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 3 Nos. 40A 4P MCCB (16KA) for AHU`s 4 Nos. 32A 4P MCCB (16KA) for AHU`s 2 Nos. 40A 4P MCB (10KA) for LDB 2.1.1 and LDB 2.1.3 2 Nos. 63A 4P MCB (10KA) for PDB 2.1.2 and PDB 2.1.4 2 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 1 Nos. 32A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel Second MDB 2.1 as described above

1

217732

217732

... More
Electrical Panel Second-MDB 2.2 INCOMER 1 No. of 100A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 100/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 120 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 36 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 3 Nos. 40A 4P MCCB (16KA) for AHU`s 3 Nos. 32A 4P MCCB (16KA) for AHU 2 Nos. 40A 4P MCB (10KA) for LDB 2.2.1 and LDB 2.2.3 2 Nos. 63A 4P MCB (10KA) for PDB 2.2.2 and PDB 2.2.4 2 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 1 Nos. 32A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel Second MDB 2.2 as described above

1

153742

153742

... More
Electrical Panel Third-MDB 3.1 INCOMER 1 No. of 100A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 100/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 120 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 2 Nos. 40A 4P MCCB (16KA) for AHU`s 7 Nos. 32A 4P MCCB (16KA) for AHU`s 2 Nos. 40A 4P MCB (10KA) for LDB 3.1.1 and LDB 3.1.3 2 Nos. 63A 4P MCB (10KA) for PDB 3.1.2 and PDB 3.1.4 2 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 1 Nos. 32A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel Third MDB 3.1 as described above

1

153742

153742

... More
Electrical Panel Third-MDB 3.2 INCOMER 1 No. of 100A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 100/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 120 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 1 Nos. 40A 4P MCCB (16KA) for AHU 7 Nos. 32A 4P MCCB (16KA) for AHU`s 2 Nos. 40A 4P MCB (10KA) for LDB 3.2.1 and LDB 3.2.3 2 Nos. 63A 4P MCB (10KA) for PDB 3.2.2 and PDB 3.2.4 2 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 1 Nos. 32A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel Third MDB 3.2 as described above

1

153742

153742

... More
Electrical Panel Fourth-MDB 4.1 INCOMER 1 No. of 100A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 100/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 120 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 2 Nos. 40A 4P MCCB (16KA) for AHU`s 2 Nos. 32A 4P MCCB (16KA) for AHU 2 Nos. 40A 4P MCB (10KA) for LDB 4.1.1 and LDB 4.1.3 2 Nos. 63A 4P MCB (10KA) for PDB 4.1.2 and PDB 4.1.4 2 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 1 Nos. 32A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel Fourth MDB 4.1 as described above

1

153742

153742

... More
Electrical Panel Fourth-MDB 4.2 INCOMER 1 No. of 100A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 100/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 120 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 2 Nos. 40A 4P MCCB (16KA) for AHU 2 Nos. 40A 4P MCB (10KA) for LDB 4.2.1 and LDB 4.2.3 2 Nos. 63A 4P MCB (10KA) for PDB 4.2.2 and PDB 4.2.4 1 Nos. 32A 4P MCB (10KA) for Axial Flow Fan 1 Nos. 40A 4P MCCB (16KA) for Spare 2 Nos. 63A 4P MCB (10KA) for Spare 1 Nos. 32A 4P MCB (10KA) for Spare Electrical Panel Fourth MDB 4.2 as described above

1

153742

153742

... More
Electrical Panel Terrace-MDB T1 INCOMER 1 No. of 63A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 63/5A with class 0.5 Accuracy for Metering, burden 15 VA BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 80 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 36 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 3 Nos. 63A 4P MCB (10KA) TDB and Spare 3 Nos. 40A 4P MCB (10KA) TDB and Spare 3 Nos. 32A 4P MCB (10KA) for Axial Flow Fan and Spare Electrical Panel Terrace MDB T1 as described above

1

37397

37397

... More
MAIN LIFT PANEL INCOMER 1 No. 125 amps 4P MCCB(25 KA). 1 Set of phase indicating lamps with single pole MCB. 1 Set of Breaker `ON` and `OFF/TRIP indicating lamps. 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-125A) Ammeter with ASS with 3 nos. 125/5A CT`s BUS-BAR Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 150 amps having a maximum current density of 1 amp per sq mm. The neutral busbar is to be of 50% capacity. OUTGOINGS 2 Nos. 63A 4P MCCB (25KA) for Sub-Lift Panel`s 1 Nos. 80A 4P MCCB (25KA) for Sub-Lift Panel 1 Nos. 80A 4P MCCB (25KA) for Spare Main Lift Panel as described above

1

91414

91414

... More
SUB LIFT PANEL-1 INCOMER 1 No. 80 Amp 4P On Load Auto Change Over Switch. 1 No. 80 amps 4P MCCB(25 KA). 1 Set of phase indicating lamps with single pole MCB. 1 Set of Breaker `ON` and `OFF/TRIP indicating lamps. 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-80A) Ammeter with ASS with 3 nos. 80/5A CT`s BUS-BAR Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 100 amps having a maximum current density of 1 amp per sq mm. The neutral busbar is to be of 50% capacity. OUTGOINGS 4 Nos. 63A 4P RCBO(100 mA) For Lift 1 Nos. 32A 4P MCB (10KA) for MDB Sub-Lift Panel-1 as described above

1

49862

49862

... More
SUB LIFT PANEL-2 INCOMER 1 No. 63 Amp 4P On Load Auto Change Over Switch. 1 No. 63 amps 4P MCCB(16 KA). 1 Set of phase indicating lamps with single pole MCB. 1 Set of Breaker `ON` and `OFF/TRIP indicating lamps. 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 100 amps having a maximum current density of 1 amp per sq mm. The neutral busbar is to be of 50% capacity. OUTGOINGS 2 Nos. 63A 4P RCBO(100 mA) For Lift 1 Nos. 32A 4P MCB (10KA) for MDB Sub-Lift Panel-2 as described above

1

49862

49862

... More
SUB-LIFT PANEL-3 INCOMER 1 No. 63 Amp 4P On Load Auto Change Over Switch. 1 No. 63 amps 4P MCCB(16 KA). 1 Set of phase indicating lamps with single pole MCB. 1 Set of Breaker `ON` and `OFF/TRIP indicating lamps. 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 100 amps having a maximum current density of 1 amp per sq mm. The neutral busbar is to be of 50% capacity. OUTGOINGS 2 Nos. 63A 4P RCBO(100 mA) For Lift 1 Nos. 32A 4P MCB (10KA) for MDB Sub-Lift Panel-3 as described above

1

49862

49862

... More
Providing and fixing in position approved make pedal type flow switches complete with copper control wiring .These shall be BMS compatible. 200 mm dia.MAKE: SIEMENS,EMERALD,ANERGY,DANFOSS

1

13104

13104

... More
MAIN UPS INPUT PANEL INCOMER 1 Nos. 250 amps 4P MCCB(25 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-250A) Ammeter with ASS with 3 nos. 250/5A CT`s BUS-BAR 1 Set of 300A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 160A 4P MCCB (25KA) for UPS (100 KVA Each) MAIN UPS INPUT PANEL as described above

1

99725

99725

... More
Supply, fabrication, installation and testing of non-porous flexible connections constructed of fire resistance flexible, double canvas connection as per the approved shop drawings.

75

163800

2184

... More
UPS OUTPUT PANEL INCOMER 3 Nos. 160A 4P MCCB (25KA) and Standby METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT`s BUS-BAR 1 Set of 300A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 1 Nos.63A 4P MCCB (16KA) for Sub-UPS Panel Basement-2 1 Nos. 63A 4P MCCB (16KA) for Sub-UPS Panel Basement-1 1 Nos. 63A 4P MCCB(16KA) for Sub-UPS Panel-1 Ground Floor 1 Nos. 63A 4P MCCB (16KA) for Sub-UPS Panel-2 Ground Floor 1 Nos. 80A 4P MCCB (25KA) for Sub-UPS Panel-1 First Floor 1 Nos. 80A 4P MCCB (25KA) for Sub-UPS Panel-2 First Floor 1 Nos. 80A 4P MCCB (25KA) for Sub-UPS Panel-1 Second Floor 1 Nos. 80A 4P MCCB (25KA) for Sub-UPS Panel-2 Second Floor 1 Nos. 63A 4P MCCB (16KA) for Sub-UPS Panel-1 Third Floor 1 Nos. 63A 4P MCCB (16KA) for Sub-UPS Panel-2 Third Floor 1 Nos. 63A 4P MCCB (16KA)for Sub-UPS Panel-1 Fourth Floor 1 Nos. 63A 4P MCCB (16KA) for Sub-UPS Panel-2 Fourth Floor MAIN UPS OUTPUT PANEL as described above

1

274243

274243

... More
Supply, installatio, testing, balancing and commissioning of extruded aluminium powder coated door transfer grill mesh with matching flange at rear side as required.600 mm X 150 mm Size

30

19230

641

... More
SUB UPS PANEL BASEMENT-2 INCOMER 1 Nos. 63 amps 4P MCCB(16 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.1, LDB-U1.2 and Spare Sub UPS Panel Basement-2 as described above

1

24516

24516

... More
Supplying, installing, testing and commissioning of Fresh Air powder coated Anodized extruded aluminium construction fresh air louvers (50 mm deep) (Fresh air louver with VCD , bird screen and rattle-free) complete as per specification.

4.2

45864

10920

... More
SUB UPS PANEL BASEMENT-1 INCOMER 1 Nos. 63 amps 4P MCCB(16 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.1, LDB-U1.2 and Spare Sub UPS Panel Basement-1 as described above

1

24516

24516

... More
Supplying, installing, testing and commissioning of Exhaust Air powder coated Anodized extruded aluminium construction fresh air louvers (50 mm deep) air louver without VCD , bird screen and rattle-free)complete as per specification.

4

30052

7513

... More
SUB UPS PANEL-1 GROUND FLOOR INCOMER 1 Nos. 63 amps 4P MCCB(16 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.1, LDB-U1.3 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.2, PDB-U1.4 and Spare Sub UPS Panel-1 Ground Floor as described above

1

24516

24516

... More
SUB UPS PANEL-2 GROUND FLOOR INCOMER 1 Nos. 63 amps 4P MCCB(16 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.5, LDB-U1.7 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.6, PDB-U1.8 and Spare Sub UPS Panel-2 Ground Floor as described above

1

27009

27009

... More
SUB UPS PANEL-1 FIRST FLOOR INCOMER 1 Nos. 80 amps 4P MCCB(25 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-80A) Ammeter with ASS with 3 nos. 80/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.1, LDB-U1.3 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.2, PDB-U1.4 and Spare Sub UPS Panel-1 First Floor as described above

1

27009

27009

... More
SUB UPS PANEL-2 FIRST FLOOR INCOMER 1 Nos. 80 amps 4P MCCB(25 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-80A) Ammeter with ASS with 3 nos. 80/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.5, LDB-U1.7 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.6, PDB-U1.8 and Spare Sub UPS Panel-2 First Floor as described above

1

27009

27009

... More
SUB UPS PANEL-1 SECOND FLOOR INCOMER 1 Nos. 80 amps 4P MCCB(25 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-80A) Ammeter with ASS with 3 nos. 80/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.1, LDB-U1.3 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.2, PDB-U1.4 and Spare Sub UPS Panel-1 Second Floor as described above

1

27009

27009

... More
SUB UPS PANEL-2 SECOND FLOOR INCOMER 1 Nos. 80 amps 4P MCCB(25 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-80A) Ammeter with ASS with 3 nos. 80/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.5, LDB-U1.7 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.6, PDB-U1.8 and Spare Sub UPS Panel-2 Second Floor as described above

1

27009

27009

... More
SUB UPS PANEL-1 THIRD FLOOR INCOMER 1 Nos. 63 amps 4P MCCB(16 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.1, LDB-U1.3 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.2, PDB-U1.4 and Spare Sub UPS Panel-1 Third Floor as described above

1

27009

27009

... More
Supplying, fixing, testing, commissioning of swirl diffusers made of pressed aluminium sheet complete with coller and duly powder coated finish.Shape and colour shall be finalised as per ceiling plan by respected consultants.Shape and colour shall be finalised as per ceiling plan by respected consultants.Complete as required.

10

131040

13104

... More
Supplying, fixing, testing, commissioning of Jet diffuser(eyeball).Shape and colour shall be finalised as per ceiling plan by respected consultants.Complete as required.

10

96100

9610

... More
SUB UPS PANEL-2 THIRD FLOOR INCOMER 1 Nos. 63 amps 4P MCCB(16 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.5, LDB-U1.7 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.6, PDB-U1.8 and Spare Sub UPS Panel-2 Third Floor as described above

1

27009

27009

... More
SUB UPS PANEL-1 FOURTH FLOOR INCOMER 1 Nos. 63 amps 4P MCCB(16 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.1, LDB-U1.3 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.2, PDB-U1.4 and Spare Sub UPS Panel-1 Fourth Floor as described above

1

27009

27009

... More
Supply, installation, testing and balancing of Powder Coated Extruded Aluminium Linear supply Air Multi Slot Diffuser complete with air pattern controllers and Hit and Miss volume control damper with acoustically line 22 G G.I plenum for Supply air ,duly insulated with 9 mm Thick Cross Linked Polyethlene Foam as per specifications and approved drawings.

10

139780

13978

... More
SUB UPS PANEL-2 FOURTH FLOOR INCOMER 1 Nos. 63 amps 4P MCCB(16 KA) METERING and INDICATION 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT`s BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS SECTION 3 Nos. 40A 4P MCB (10KA) for LDB-U1.5, LDB-U1.7 and Spare 3 Nos. 40A 4P MCB (10KA) for PDB-U1.6, PDB-U1.8 and Spare Sub UPS Panel-2 Fourth Floor as described above

1

27009

27009

... More
Supply, installation, testing and commissioning of Powder Coated Extruded Aluminium Multi Slot return Air Diffuser with air pattern controller as per specification and approved drawings.

10

96100

9610

... More
VENTILATION PANEL BASEMENT-2 INCOMING 1 No. of 125A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 125/5A with class 0.5 Accuracy for Metering, burden 15 VA BUSBARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 160 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 5 Nos. 63A 4P MCCB (16KA) for Axial Flow Fan and Spare 5 Nos. 63A 4P MCCB (16KA) for Make Up Air Fan and Spare VENTILATION PANEL BASEMENT-2 as discribed above

1

195294

195294

... More
Supply, installation, testing and commissioning of Eccentric square-to-round transitions duct piece to connect rectangular duct to round duct,The square connector has a flange frame in the standard version,The round connector is male in the standard version.

88

422840

4805

... More
VENTILATION PANEL BASEMENT-1 INCOMING 1 No. of 100A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 100/5A with class 0.5 Accuracy for Metering, burden 15 VA BUSBARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 120 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 5 Nos. 63A 4P MCCB (16KA) for Axial Flow Fan and Spare VENTILATION PANEL BASEMENT-1 as discribed above

1

106789

106789

... More
VENTILATION PANEL-1 TERRACE FLOOR (OUTDOOR TYPE-IP 65) INCOMING 1 No. of 125A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 125/5A with class 0.5 Accuracy for Metering, burden 15 VA BUSBARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 160 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 8 Nos. 63A 4P MCCB (16KA) for Axial Flow Fan and Spare VENTILATION PANEL-1 TERRACE FLOOR as discribed above

1

121747

121747

... More
VENTILATION PANEL-2 TERRACE FLOOR (OUTDOOR TYPE-IP 65) INCOMING 1 No. of 125A 4P Moulded Circuit Breaker with Ics=Icu=Icw 25KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 125/5A with class 0.5 Accuracy for Metering, burden 15 VA BUSBARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 160 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 8 Nos. 63A 4P MCCB (16KA) for Axial Flow Fan and Spare VENTILATION PANEL-2 TERRACE FLOOR as discribed above

1

121747

121747

... More
EXTERNAL LIGHTING FEEDER (OUTDOOR TYPE-IP 65) INCOMING 1 No. of 63A 4P Moulded Circuit Breaker with Ics=Icu=Icw 16KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Nos. 63A 4P Contactor 1 Set of phase indicating LED lamps BUSBARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 100 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 9 Nos.16A 4P MCB (10 KA) and Spare EXTERNAL LIGHTING FEEDER as discribed above

1

67730

67730

... More
VENTILATION PANEL-3 TERRACE FLOOR ATRIUM (OUTDOOR TYPE-IP 65) INCOMING 1 No. of 300A 4P Moulded Circuit Breaker with Ics=Icu=Icw 36KA Thermal Magnetic releases for O/L, S/C and E/F. 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CT`s 1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP MCB`s. 1 Set of CTs of the ratio 300/5A with class 0.5 Accuracy for Metering, burden 15 VA BUSBARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 400 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 18 Nos. 63A 4P MCCB (16KA) for Axial Flow Fan and Spare VENTILATION PANEL-3 TERRACE FLOOR ATRIUM as discribed above

1

186984

186984

... More
Supply of thermal insulated flexible duct of 100/150 mm dia duly supported at regular interval as per site requirement etc. complete as required as per specifications.

150

196500

1310

... More
Supplying, Installation, Testing and Commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB (but without MCCB) complete etc. as Required 63 A 25kA SC for 1 sec

2

14810

7405

... More
Supply of circular exhaust/disc valve of powder coated aluminium material with foam gasket for toilet exhaust. Colour shall be finalised as per ceiling plan by respected consultantscomplete as required as per specifications. Make: For above ADS: Air flow,Ruskin Titus. For Insulation:Armacell,Kflex,Supreme,ALP

10

13100

1310

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 3 ½ C - 300 sq mm Aluminium

1790

2649200

1480

... More
Supplying, Receiving, Fixing, Testing and Commissioning of HVAC Plant Room Panel made out of 14 SWG sheet as described above

1

1092000

1092000

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 3 ½ C - 240 sq mm Aluminium

395

471235

1193

... More
32A 4P MPCB with 7.5 HP DOL Starter for Pressurization Fan

4

60480

15120

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 3 ½ C - 120 sq mm Aluminium

100

63500

635

... More
40A 4P MPCB with 10.0 HP Star-Delta Starter for Pressurization Fan

11

192192

17472

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 3 ½ C - 95 sq mm Aluminium

695

353755

509

... More
32A 4P MPCB with 7.5 HP DOL Starter for Smoke Exhaust

13

204425

15725

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 3 ½ C - 70 sq mm Aluminium

230

92230

401

... More
25A 4P MPCB with 3.0 HP DOL Starter for Smoke Exhaust

15

131040

8736

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 3 ½ C - 50 sq mm Aluminium

280

84000

300

... More
25A 4P MPCB with 1.0 to 3.0 HP DOL Starter

3

74955

24985

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 3 ½ C - 35 sq mm Aluminium

240

53520

223

... More
32A 4P MPCB with 7.5 HP DOL Starter

8

251600

31450

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 4C- 25 sq mm Aluminium

330

64680

196

... More
25A 4P MPCB with 5.0 HP DOL Starter

2

55910

27955

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 4C- 16 sq mm Aluminium

735

113925

155

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 4C- 10 sq mm Copper

50

19150

383

... More
40A 4P MPCB with 10.0 HP Star-Delta Starter

10

366910

36691

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 4C- 6 sq mm Copper

200

45800

229

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. As per HPHC Brandlist 4C- 4 sq mm Copper

750

114750

153

... More
Supply of following sizes of 11KV XLPE grade multicore stranded aluminium conductor (Earthed), XLPE insulated and PVC sheathed armoured cable conforming to IS: 7098 (Part-I) 1988 complete as required and as per specification encolsed. 3 Core, 240 Sq.mm

160

310720

1942

... More
3 ½ C - 240 sq mm Aluminium

83

180525

2175

... More
Supply, laying and fixing of following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor with end termination glands power/ multicore control armoured cable of 1.1 KV grade.(Cables exposed to sunlight and rain to be UV resistant or UV safe by coating it with paramount paint.Make:KEI,Havells,Polycab.3 ½ C - 300 sq mm Aluminium.Note:All Cables from panel to Axial/Jet/CO senser Fans shall be fire survival cables.

80

211680

2646

... More
Supply, installation, testing and commissioning of 45W LED street Light with integral control gear comprising heavy duty copper ballast , PF improvement capacitor, connection and wiring from junction box with 3# 2.5 sqmm copper wires, Mounted on existing 6 mtr. pole.

42

55398

1319

... More
Supply, laying and fixing of following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor with end termination glands power/ multicore control armoured cable of 1.1 KV grade.(Cables exposed to sunlight and rain to be UV resistant or UV safe by coating it with paramount paint.Make:KEI,Havells,Polycab.4C- 70 sq mm Aluminium.Note:All Cables from panel to Axial/Jet/CO senser Fans shall be fire survival cables.

75

55950

746

... More
Supply, installation, testing and commissioning of 60W LED Post Top Light - Supply of Pole mounted LED Post Top luminaire ,luminous efficiency of luminaire = 100 lm/W colour rendering index Ra ) 70. Service life L70(tq 25 °C) = 50,000 h, CCT-3000K.Pressure die cast aluminium housing with Luminaire cover made of Polycarbonate/PMMA ,symmetrical wide light distribution and Ingress Protection rating IP65 . Power Factor = 0.95, THD should be = 10%. Surge protection should be = 10kV . All luminaires shall be with associated driver , lamp and other connecting or mounting accessories to make it complete in all respect for operational purpose. The supplier shall submit the technical specification sheets alongwith LM reports for approval.

4

31256

7814

... More
Supply, laying and fixing of following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor with end termination glands power/ multicore control armoured cable of 1.1 KV grade.(Cables exposed to sunlight and rain to be UV resistant or UV safe by coating it with paramount paint.Make:KEI,Havells,Polycab.4C- 35 sq mm Aluminium .Note:All Cables from panel to Axial/Jet/CO senser Fans shall be fire survival cables.

75

35625

475

... More
Supply, laying and fixing of following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor with end termination glands power/ multicore control armoured cable of 1.1 KV grade.(Cables exposed to sunlight and rain to be UV resistant or UV safe by coating it with paramount paint.Make:KEI,Havells,Polycab. 4C- 16 sq mm Aluminium .Note:All Cables from panel to Axial/Jet/CO senser Fans shall be fire survival cables.

83

22991

277

... More
Supply and fixing of decorative 8 to 10 Watt LED bollard (600 mm) luminaire with driver set confirming to IP 66 protection complete in all respect.

25

85675

3427

... More
Supply, laying and fixing of following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor with end termination glands power/ multicore control armoured cable of 1.1 KV grade.(Cables exposed to sunlight and rain to be UV resistant or UV safe by coating it with paramount paint.Make:KEI,Havells,Polycab. 4C- 10 sq mm Aluminium .Note:All Cables from panel to Axial/Jet/CO senser Fans shall be fire survival cables.

250

58750

235

... More
Supply and fixing of factory wired integral LED flood light luminaries with die cast aluminium housing built with driver set suitable for 80 to 90 watt. Confirming to IP 66 protection complete in all respect.

10

61690

6169

... More
Supply and fixing of 10 Watt LED tree uplighter with driver set confirming to IP 66 protection complete in all respect.

25

102825

4113

... More
Supply, laying and fixing of following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor with end termination glands power/ multicore control armoured cable of 1.1 KV grade.(Cables exposed to sunlight and rain to be UV resistant or UV safe by coating it with paramount paint.Make:KEI,Havells,Polycab. 4C- 6 sq mm Aluminium Note:All Cables from panel to Axial/Jet/CO senser Fans shall be fire survival cables.

150

30000

200

... More
Supply and fixingof 60W Smart integrated solar street light with all in one Hybrid with system with built in Mono Crystalline panel, Lithium ferro phospate (Life PO 4) battery, MPPT charge controller and PIR Sensr with colour temperature 6000-6500K without pole and bracket.

5

299880

59976

... More
Supply, laying and fixing of following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor with end termination glands power/ multicore control armoured cable of 1.1 KV grade.(Cables exposed to sunlight and rain to be UV resistant or UV safe by coating it with paramount paint.Make:KEI,Havells,Polycab. 4C- 4 sq mm Copper Note:All Cables from panel to Axial/Jet/CO senser Fans shall be fire survival cables.

94

38540

410

... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc. as required.Provider:Aditya Steel,Asawa,MEM.300 mm width X 50 mm depth X 1.6 mm thickness

150

69300

462

... More
Supply of long life Maintenance Free Earthing System. The Rod shall be of Copper Bonded Steel with 17.2 mm dia. and 10 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm both tested by CPRI capable of bearing fault current of 25 kA. Along with earth enhancement compound tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 30 kg (10 kg Bag x 3) resistivity is less than 0.12 ohm meter . with Suitable Poly-plastic Pit Cover with lockable arrangement. The chemical earth pit shall have minimum 25 years waranty with all term and conditions. Make-JMV, Furse

64

645824

10091

... More
Supply, errection, testing and commissioning of 13 passanger machine room less Electric Traction Elevator, to be errected in accordance with followingTechnical Specification and as per latest IS Specifications. Nos. of Lifts 1 Nos. Type and Capacity:Passanger Elevator App. 884 kg. 13 person. Dimension : 2500mm x 1900mm (WxD) `Specification: Basement-2, Basement-1, GF, 1st F, 2nd F, 3rd F, 4th F and Terrace floor Floor Height: Basement (4 mtr) and GF to Terrace (3.5 mtr)` Speed mps : 1.5 mtr per second Travelling (max.) in mtrs : Approx. 29.0 mtrs Serving : 8 stops, 8 opening (All opening on the same side). Power Supply : 415V, 3 phase, 50 HZ AC supply. Control : Simplex full collectivecontrol with or without attendant. Operation : Automatic Motor : A Synchronous motor Car Size : as per manufacturer design. Door Frame : Full Glass Door. Other Features : Battery operated emergency alarm and emergency light with rechargeable battery. Adjustable guide shoes. Combine Luminous hall buton and digital hall indicator/touch screen. Integral full height car opening panel with luminouscombined with direction arrows, overload warning indicacator and service cabinet. Hand free press and speak intercom with EPABX for three way communication. Automatic rescue device to automatic bring the elevator to a landing in case of power / phase failure/ low voltage. Full height Infrared safety curtain and automatic floor announcer. Diffused Lighting in car. Blower (noiseless) Looking mirror in front side of lift car. Face Plate finish : Stainless stell in hairline. Face Plate : Rectangular. The Three feet high railing shall be provided on car top. The motor shall be high starting torque and low starting current and shall be arranged for self lubrication. Proper weight screen shall be provided at the hoist way. Fire retardant compound coated traveling cable shall be used. 2Phase Device Fire Man Drive and Fireman switch at ground floor. Load Weight device with overload bypass feature. Steel itels such as Door Frames Sill angles, Fascia Plates, Spring Buffers. Bralite Features, Lift announcement system, Pit ladder, Hand Rail and Additional Car Gate Lock. Three side Hand Rail in Stainless Steel Finish. System Capable of withstanding plus 10% to -10% Variation in Supply Voltage Fluctuations. Car Plateform constructed out of Cold Rolled Grain Oriented Formed Sheets of Steel. Fire Rated landing Doors for a period of one hours only. The whole machinery shall be mounted on appropriate anti vibration supports to minimize voice and vibration.

2

4798080

2399040

... More
Supply, errection, testing and commissioning of 8 passanger machine room less Electric Traction Elevator, to be errected in accordance with followingTechnical Specification and as per latest IS Specifications. Nos. of Lifts 1 Nos. Dimension : 2000mm x 1900mm (WxD) `Specification: Basement-2, Basement-1, GF, 1st F, 2nd F, 3rd F, 4th F and Terrace floor Floor Height: Basement (4 mtr) and GF to Terrace (3.5 mtr)` Type and Capacity:Passanger Elevator App. 544 kg. 8 person. Speed mps : 1.5 mtr per second Travelling (max.) in mtrs : Approx. 29.0 mtrs Serving : 8 stops, 8 opening (All opening on the same side). Power Supply : 415V, 3 phase, 50 HZ AC supply. Control : Simplex full collectivecontrol with or without attendant. Operation : Automatic Motor : A Synchronous motor Car Size : as per manufacturer design. Door Frame : Full Glass Door. Other Features : Battery operated emergency alarm and emergency light with rechargeable battery. Adjustable guide shoes. Combine Luminous hall buton and digital hall indicator/touch screen. Integral full height car opening panel with luminouscombined with direction arrows, overload warning indicacator and service cabinet. Hand free press and speak intercom with EPABX for three way communication. Automatic rescue device to automatic bring the elevator to a landing in case of power / phase failure/ low voltage. Full height Infrared safety curtain and automatic floor announcer. Diffused Lighting in car. Blower (noiseless) Looking mirror in front side of lift car. Face Plate finish : Stainless stell in hairline. Face Plate : Rectangular. The Three feet high railing shall be provided on car top. The motor shall be high starting torque and low starting current and shall be arranged for self lubrication. Proper weight screen shall be provided at the hoist way. Fire retardant compound coated traveling cable shall be used. 2Phase Device Fire Man Drive and Fireman switch at ground floor. Load Weight device with overload bypass feature. Steel itels such as Door Frames Sill angles, Fascia Plates, Spring Buffers. Bralite Features, Lift announcement system, Pit ladder, Hand Rail and Additional Car Gate Lock. Three side Hand Rail in Stainless Steel Finish. System Capable of withstanding plus 10% to -10% Variation in Supply Voltage Fluctuations. Car Plateform constructed out of Cold Rolled Grain Oriented Formed Sheets of Steel. Fire Rated landing Doors for a period of two hours only. The whole machinery shall be mounted on appropriate anti vibration supports to minimize voice and vibration.

2

4536000

2268000

... More
Supply, errection, testing and commissioning of ERD (Emergency Rescue device) with battery bank for 30 minutes operation in case of power failure. The ERD shall be equiped with voice anouncement system.

4

823200

205800

... More
RFID base boom barier with 6 metre wide Strong aluminium arm with rubber guard, Strong aluminium arm with rubber guard, Manual lock release by key in case of power failure, Green light and red light indicating the position of the beam, Connections for infrared photocell, loop detector and IC system for other functions, Stop and reverse operation safety devices, Provision for connecting an RFTD system. Function Open the door by scanning the tag. After being stopped for a specific time, the system will automatically send a signal to close the barrier The system can be configured with an ro card reader, allowing addition and deletion of users. Technical Specification Clear opening width 6 mtr Power Supply- 230 V ~I 50 - 60 Hz Control Panel- 24V Torque- 250Nm Opening Time- 1 - 2 s/90° Protection Rating- IP 54 Operating Temprature- -20 degreeto plus 50 degree Travel Control System- Encoder RFID READER RFlD UHF readers to enable the tagged vehicle identification from 10-12 meter distance so that it is convenient for drivers to access the boom barrier without stopping the vehicle. Teachnical Feature: Frequency- 865-867 MHz Power Output- 865-867 MHz `Communication- 10/100 BaseT Ethernet (RJ45): USB Host and Client T e A and B) or Serial DB9)` Operating Temprature- -20 degreeto plus 50 degree Humidity- 5-95% non-condensing

2

581728

290864

... More
Supplying, installation, testing and commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 630 A Isc = 50kA for 1 second

2

23808

11904

... More
Supply, installation, testing and commissioning of core i7-4790k or Xeon E5-1650 v3 processor, Memory of 32 GB, Hard disk size (2x 800 GB Professional/Enterprise SSD with SATA or SAS), Giga speed Network card with 2 GB Graphic card of Resolution 2.560 x 1600 with Onboard Intel 4600 HD Windows 8.1, 64 bit Edition or Windows Server 2008 R2 and original anti virus software.32 Inch HD Color LED Monitor.Laser jet Printer 100 Page per mint. (A4 size, Colour) model:-

1

104366

104366

... More
`Supply, installation, testing and commissioning of Layer 2/3 managed switch with 16 or 24 ports (RJ-45) port. The switch shall have 2 RSTP enabled ports to communicate with other switches to built a ring topology network on CAT6 A cable. The switch shall have 1 GB port to communicate with other switches including Passive components inbuilt 2 SFP ports including SFP modules, rack mountable, SMPS power supply and other termination accessories (Like Pigtails/LIUs/ Convertors/Splicing equipment ,Patch panel, Patch Cord, Etc) complete as per specifications and as required for BMS DDC Panel Networking. The switch to switch distance shall not exceed beyond 80 meters. Vendor to decide the quantity of network switches based on their network design.`

1

81536

81536

... More
`Supply, Installation, Testing and Commissioning of software for Building Management Software with features like 3D vector dynamic graphics with Autocad import of plan with Zoom In and Zoom Out facility, Graphic Builder, Plant Viewer, Trend Viewer, Object Viewer, Report Viewer, Alarm router, Log Viewer. The Web-Based Server software shall permit use of Standard Web-Browsers such as Microsoft Internet Explorer, Netscape Navigator, etc. The software shall be capable of integartion third-party systems and should supports latest IP technology (IP V4/V6). The Management Stations shall match the BACnet Profile B-AWS (Advanced workstation) as per the BTL Listing. The Web based software shall include 1 Client License for remote viewing. The same includes the necessary dongles as required for each of the workstation. Sms/Email feature for accessing critical alarms on mobile phone and Mobile App and Web Service sessions. The Vendor shall include cost of GSM Module in the quoted price. Number of IO points shall be considered as per the IO summary considering 15% spares. (Make:- Siemens/Carrier ALC/Honeywell EBI)`

1

83493

83493

... More
Supply, Installation, Testing and Commissioning of High-quality CAPACTIVE touch 7.0`` panels for technical on-site operation of plants as well as room operation. The Touch Panel shall have integrated web server and a BACnet/ IP web interface to connect a HTML5 browser to a device on the network. Generic operation and monitoring of plant functions (alarms, schedulers, calendars, set point changes, display of actual values, etc.)

1

58706

58706

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. HVAC and Ventilation system DDC for Chilled Plant Manager includes Chiller, Primary, Secondary,Hot Water Pumps.

1

159811

159811

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. HVAC and Ventilation system DDC for Air Handling Units/CSU (Max 2 AHU per DDC)

40

1330680

33267

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. HVAC and Ventilation system DDC for FCU (Max 2 FCU per DDC)

25

797425

31897

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. HVAC and Ventilation system DDC for Exhaust Fans

40

1341640

33541

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. HVAC and Ventilation system DDC for Air Washer and Scrubber Units (3)

1

6523

6523

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. Electrical System DDC for DG Set/ Transformer and LT Panel

1

101757

101757

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. Electrical System DDC for Lifts

1

62620

62620

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. Plumbing System DDC for Fire Fighting System

1

40768

40768

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. Plumbing System DDC for Sump and Water Pumps

1

65229

65229

... More
Supply, Installation, Testing and Commissioning of True IP Based Standalone 32 Bit Intelligent, BTL Listed and UL certified interoperable DDC as per the specification. Each DDC Controller shall have inbuilt IP port and shall directly connect to the Network switches. No Supervisory Controller/Router shall be acceptable for IP conversion. The DDC shall be Programmable and Application specific with Real Time clock.The Controller shall have minimum 18 onboard points and can be expandable upto max of 52 points. The DDC must support trending and scheduling at Controller level. All trend data must be created and saved to the automation station to achieve gap-free trend documentation during communication failure. The above shall be housed in IP 55 vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion. Plumbing System DDC for Water Tank

1

48922

48922

... More
Supply, Installation, Testing and Commissioning of Immersion temperature sensor 100 mm Pt1000 with Brass Thermowell.

102

279480

2740

... More
`Supply, Installation, Testing and Commissioning of True IP Based System Integration unit consisting of microprocessor based controller units BTL and UL Listed for third party integration. The same should support operations/ monitoring via portable operator terminal. .The controller shall be Native BACnet type with communication via BACnet/LonTalk, Integration platforms and system controllers for third-party devices and systems via KNX, Modbus, M-Bus and other protocols into the automation level via BACnet. The same shall Support operation via local or network-compatible operator units. It should store trend logs and event buffer for a typical duration of up to 30 Days. All the Integrators shall be seperate. Note: No 3rd party make integartor shall be accepted. (Make:- Siemens/Carrier /Honeywell )`

1

366912

366912

... More
Supply, Installation, Testing and Commissioning of Outside air temperature plus humidity sensors for measuring outside air temperature. It should be provided with sun sheild and rain protection.

1

18916

18916

... More
Supply, Installation, Testing and Commissioning of Differential Pressure Switch Water for pumps

24

242640

10110

... More
Supply, Installation, Testing and Commissioning of Water Flow Switch

1

9458

9458

... More
Supply, Installation, Testing and Commissioning of DuctTemp Sensor for AHU

20

58700

2935

... More
Supply, Installation, Testing and Commissioning of Differential pressure switch for Blower Status (Pa Range 50…300 Pa)

20

54800

2740

... More
Supply, Installation, Testing and Commissioning of Level Switch for sump

10

252810

25281

... More
Supply, Installation, Testing and Commissioning of Flameproof Level Transmitter

3

264177

88059

... More
Supply, Installation, Testing and Commissioning of Bi Level Switch water tanks

10

189160

18916

... More
Supply, Installation, Testing and Commissioning of Pressure sensor for lift lobby/lift well/staircase

5

50550

10110

... More
Supplying, laying, termination, testing and commissioning of signal cables. (2 core x 1.5 Sq.mm), PVC insulated, Shielded tinned copper conductor cable.

1500

96000

64

... More
Supplying, laying, termination, testing and commissioning of signal cables. (4 core x 1.5 Sq.mm), PVC insulated, Shielded tinned copper conductor cable.

500

60000

120

... More
Supplying, laying, termination, testing and commissioning of 3 Core 1.5 Sqmm, unarmoured ATC conductor multistranded, FRLS cable for Powering DDC , Actuators.

1500

142500

95

... More
Supplying, laying, termination, testing and commissioning of CAT 6A unarmoured Cables with required accessories like RJ45 connector etc.

1500

70500

47

... More
Supply, Installation, Testing and Commissioning of MS Conduit 25 mm for Signal and Communication Cable

1500

136500

91

... More
Supply, Installation, Testing and Commissioning of GI Flexible

800

66400

83

... More
Supplying, installing, testing and commissioning of 2 mm thick GI perforated cable trays of the following sizes complete with angle iron supports/hanging arrangement etc 100 x 50

50

12250

245

... More
Supply and installation of external thermal insulation on ducts with factory laminated 7 mill glass cloth on closed cell nitrile rubber with density min 40 Kg/ Cum for nitrile rubber, class `O`,Maximum Thermal conductivity 0.034 K.cal/ hr. degree C/m at 10 Deg C mean temp. complete as per specifications. All longitudnal and transverse joints shall be sealed with 50mm wide and 3mm thick Nitrile rubber tape. The cost shall be inclusive of Low VOC adhesive. 19 mm thick aluminum foil of mat finish with protective coating

1900

1145700

603

... More
Supply and installation of external thermal insulation on ducts with factory laminated 7 mill glass cloth on closed cell nitrile rubber with density min 40 Kg/ Cum for nitrile rubber, class `O`,Maximum Thermal conductivity 0.034 K.cal/ hr. degree C/m at 10 Deg C mean temp. complete as per specifications. All longitudnal and transverse joints shall be sealed with 50mm wide and 3mm thick Nitrile rubber tape. The cost shall be inclusive of Low VOC adhesive. 25 mm thick with protective coating

150

125850

839

... More
Supply, installation testing and commissioning of duct acoustic insulation Inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test or 10,000 fpm air velocity as per ASTM C 1071-05 to be applied using manufacturer`s recommended Rubber based Adhesive in a blend of solvents.

150

125850

839

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5C x 1.5 Sq. mm

120

16320

136

... More
Supplying, fabricating and installing following size of perforated painted with powder coating M.S. cable trays,with perforation not more than 17.5%, in covenient section, joined with connectors, suspended from the ceiling with MS suspenders including bolts and nuts, painting suspenders etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness

40

19240

481

... More
`(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.` (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 88 m Head

1

353797

353797

... More
`(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.` (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 1620 lpm at 56 m Head

1

249262

249262

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia

50

218400

4368

... More
Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. Capacity 4.5 kg

98

554680

5660

... More
Providing and Fixing of stored pressure Fire Extinguisher ABC powder type (Mono Ammonium Phosphate Powder) Magnetic Pressure Gauge having the facility to check at site, Discharge Time less than 9 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 21A, B Rating 55B as per BS EN-3 BIS 15683 marked, Can Construction : Deep drawn and CO2 Mig welded, Valve Construction : Forging and Machining, Internal Coating of Can : Epoxy Powder coating, External Coating ofCan : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, Helium LeakDetection Tested, Warranty. Capacity 6 Kg.

98

251468

2566

... More
Providing and fixing mechanical foam type Trolley Mounted Fire Extinguisher of bearing to IS:10568/IS13385/IS13386 with dis Capacity 50 Lit.

2

10262

5131

... More
Providing and fixing Carbon Dioxide Type Trolley Mounted Fire Extinguisher of as per IS: 2878 with discharge time of 10 to 20 sec/15 to 36sec/20 to 60sec respectively. 22.5 Kg. CO2 Fire Extinguisher

2

32872

16436

... More
Providing and fixing ceiling mounted type modular automatic extinguishing system with CLEAN AGENT HFC - 236 type, made of MS body treated against corrosion with heat sensitive glass bulb sprinkler heads (68deg/79deg C), pressure indicator, arrangemet for fixing to the ceiling pressurized with nitrogen gas to 15 kgf/cm2 suitable for covering 13.25 cu.mt (465 cuft) volume. 5 Kgs Capacity

10

176380

17638

... More
Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings and accessories. The door shall have a front glass with lock and key arrangement and shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor).

48

559296

11652

... More
Providing and fixing of TAC approved 1.6mm thick M.S. fire hose cabinet (750x600x250mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings and accessories. The box shall have a front glass door with lock and key arrangement and shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) - for external and roof hydrant.

13

86554

6658

... More
Providing and fixing of Fire Axe

34

18870

555

... More
Providing, fixing, testing and commissioning of full way level operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not lass than 15 kg/sq.cm with threaded/flanged complete with nuts, bolts, gaskets, washers etc. as required complete as per direction of Engineer incharge. 25 mm NB

47

47940

1020

... More
Providing, fixing, testing and commissioning of full way level operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not lass than 15 kg/sq.cm with threaded/flanged complete with nuts, bolts, gaskets, washers etc. as required complete as per direction of Engineer incharge. 50 mm NB

13

47346

3642

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 300 mm dia.

168

287280

1710

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 250 mm dia.

253

362802

1434

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 200 mm dia.

230

277380

1206

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 150 mm dia.

365

282510

774

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 125 mm dia.

250

167000

668

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 100 mm dia.

365

193815

531

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 80 mm dia.

453

201585

445

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 65 mm dia.

453

170328

376

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 50 mm dia.

450

129600

288

... More
Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect... 40 mm dia.

563

129490

230

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete,300 mm dia.

1

1989

1989

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 250 mm dia.

1

1681

1681

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 200 mm dia.

10

10010

1001

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 150 mm dia.

1

510

510

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 125 mm dia.

1

397

397

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 100 mm dia.

1

298

298

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 80 mm dia.

6

1362

227

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 65 mm dia.

15

3060

204

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 50 mm dia.

11

1958

178

... More
Insulation on Butterfly Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 40 mm dia.

25

3775

151

... More
Insulation on Non return Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 200 mm dia

6

8016

1336

... More
Insulation on balancing Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete,200 mm dia.

6

22974

3829

... More
Insulation on balancing Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 150 mm dia.

1

2032

2032

... More
Insulation on balancing Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 125 mm dia.

1

1505

1505

... More
Insulation on balancing Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 100 mm dia.

1

1063

1063

... More
Insulation on balancing Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 80 mm dia.

3

2154

718

... More
Insulation on balancing Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 65 mm dia.

10

6140

614

... More
Insulation on balancing Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 50 mm dia.

8

4440

555

... More
Insulation on balancing Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete, 40 mm dia.

11

3740

340

... More
Insulation on Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete. 200 mm dia.

6

8016

1336

... More
Insulation on Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete. 150 mm dia.

1

911

911

... More
Insulation on Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete. 125 mm dia.

1

611

611

... More
Insulation on Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete. 100 mm dia.

1

468

468

... More
Insulation on Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete. 80 mm dia.

3

1155

385

... More
Insulation on Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete. 65 mm dia.

12

4296

358

... More
Insulation on Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete. 50 mm dia.

8

2616

327

... More
Insulation on Strainer Valves by providing moulded PUF sections of density 20Kg/m3 or using nitrile rubber 20 mm thick etc as required, complete. 40 mm dia.

15

3735

249

... More
Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

6

55668

9278

... More
Providing and fixing of SS health Faucet of Jaquar make model: ALD-CHR-573 or equivalent to the satisfaction of engineer-in-charge, which can tolerate water pressure up to 6 bar flow pressure with metal hose and holder in Polished Chrome.

84

112224

1336

... More
Supply and Fixing of GRC Jali Products As Per approved designs and sizes and thickness 40-50mm Border Inner Jali Thikness 25-30 mm The Screens should be made from ‘53 grade’ White Portland Cement manufactured by ,Birla Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in Synthetic Rubber / FRP Mould manufactured by ‘Reckli’ or equivalent etc complete as per detail and design given and as per direction of Enginner in charge. (M.S Frame shall be paid for seperatly) (MAKE:- UNISTONE, NTC, GRAND)

19.37

108153

5583.56

... More
Supplying and Installation of 20mm thick Multicell Polycarbonate sheet roofing for skylight manufacture of skylight system, a complete aasemvbly of extruded cellular structure UV protected poly carbonate panels incorporated into a complete system. Multicell polycarbonate panel system with 5 cells and 6 walls structure shall be uniform in color with an integral Tight cell core. panels width 900mm and having vertical standing seam at both sides with 15-20mm height. Panel shall be having min, 45-50 microns co-extruded and UV protected on top layer (exposed to Sun) and min 15 micron on other side osf approved color / shade . Panels shall be fixed on Purlins with aluminium Brackets / I beam spacers and connected with polycarbonate U connectors to interlock the panel with snap on / click on /grip lock mechanism to ensure maximum uplift capacity. panel system shall be assembled and installe on MS Structure(paid separately) with self drilling screws. Panel shall be secured with snap on polycarbonate connector to interlock the panels have Double tooth locking with continous connector mechanism along with standing to seam to ensure maximum uplift capability with PC End Cap, complete to make a watertight skylight system. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on polycabonate sheets which have been exposed to UV for a min. 500 Hours as per ASTMG 155. Panels shall not have yellowness index as per ASTM E 313 when tested on a sample exposed to UV for 500 hours as per ASTM G 155 Panels should Pass through Flammability Test UL-94 Panels shall be sealed with aluminium U-profile (mill finish) for ends. Panel manufacture shall provide limited warranty against any manufacturing defects for a period of 10 Years. Multicell panel shall be fixed over structural steel/ MS Purlin (shall be paid extra) as per direction of Engineer-In- Charge. (Make:- Coxwell, DPI Daylighting or Equivalent)

1065.66

3687166

3459.98

... More
Providing and fixing Automatic Sliding door operator, Make: dormakaba ES 200 Easy - 6.25 Mtrs Bi-parting Sliding System, compliant with European standards and produced according to the guidelines for power-operated windows, doors and gates, BGR 232, the UVV and the VDE regulations. TÜV design tested, tested according to the low voltage guidelines, production according to ISO 9001:2000 certification, fulfils DIN18650 Standards for Pedestrian Safety, TUV Design Tested for Durability of 1 Million Cycles, for frameless glass door application, modular design including internal cover. and with 12 mm clear toughened glass for 2 Nos sliding door panel, Operator to be mounted on MS-Box Section/Equalant.Operator Finish should be Silver Anodised E6/C0, with operator dimensions Maximum (H x D) : 100 x 180 mm and of length as required to suit the opening size given below. The track profile should be separate from the main profile for enabling reduction in vibration insulation and easy maintainence. Microprocessor-controlled control unit, Selflearning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, Class of protection IP 20. Activators- dormakaba Nemo Motion plus Nemo Dual ( Safetyand Motion), Electro-mechanical Lock, and 5 Position Program Switch with key.The system shall have constant power as per detailed drawings and to the satisfaction of Engineer in Charge. supply 230V plus 5%, 50Hz, AC . Clear Passage Width = 2500 mm Clear Passage Height = 2400 mm Max Panel Weight Double Sliding = 2 x 100 Kgs.

3

830433

276811

... More
Providing and making groove cutting in floor 10x70mm thk dimond cut by using of Baker Rod and prevent for cracks complete in respect of drawing or as per direction of Engineer- in- Charge.

7726.33

927159

120

... More
Providing and Laying polysulphide sealent for groove size 10x70mm in expansion/ construction Joint to prevent cracks including filling the groove with backer rod alongwith cleaning and making joint smooth and uniform etc. complete as per direction of Engineer- in- Charge.

7726

1375228

178

... More
Providing and fixing of 6mm thick approved make tempered lacquered glass, approved color ,fixed with neutral silicon / double sided tape on perfectly leveled 12mm thick water proof marine plywood which is mounted on the RCC wall/any other structure by suitable means as approved by Engineer-in-charge complete in all respect.

281

2186461

7781

... More
Providing and fixing high density polyethylene (hdpe) with 8mm dimples board used as protection board for waterproofing to be fixed vertically on external side of retaining wall. The board should be high strength one side dimpled structure, light in weight yet flexible strong and resilient. Rate is inclusive of material, wastage, labour and overlab to the board. Actual area of the retaining wall will be measured for payment

3237.78

1304825

403

... More
Extra for Making chases in Brick for providing skirting flush with the plaster as per direction on Engineer-In-Charge.

9480.8

208577

22

... More
Extra for providing 6mm annealed Glass instead of 5mm annealed Glass as per complete satisfaction of Engineer-In-Charge.

735

90405

123

... More
Core cutting on vertical portion of walls for passing pipes of dia 110mm/150mm and 300mm core cutting depth in RCC Walls vertical

50

69000

1380

... More
Design, Supply, fabrication and fixing of acrylic, non-glare, tactile audio building layout as per the approved size, design and make, having 6mm thick acrylic non glare base plate of the approved colour and non-glare acrylic cut out symbols and upper case Sans Serif letters of 12mm height, raised 3mm above base plate and Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. The map to be installed at the specified location as per accessibility standards, shall be oriented to the position of the viewer and to be installed at a height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge. Height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed complete as per design / specifications and guidelines as per the entire satisfaction of the Engineer-in-charge (NS)

5

110170

22034

... More
Providing and fixing Multilingual and tactile Emergency evacuation map of each floor indicating the current position of the viewer saying `YOU ARE HERE` of 15mm height letters in red with white background, indicating the emergency exits, locations of fire extinguishers etc. Signs shall have a solid header with the text “EVACUATION PLAN” in contrasting uppercase letters no less than 3/4` in height. The size of the board shall be 2ft x 2ft and shall be installed at a height of 1200mm from FFL and shall be oriented to the position of the viewer as per the direction of the site engineer complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge (NS)

10

143220

14322

... More
Providing and fixing of SS, non-glare multilingual Braille (raised dots) ENTRANCE SIGNAGE (size 1 ft x 1 ft) as per the approved design and make, indicating the name of the building having 1.2mm thick SS non glare blue colored base plate with the `Universal Accessibility Symbol` and Upper case Sans Serif words of height 15mm engraved on it along with the equivalent word/ s written in Hindi using Devanagari script of height 15mm in white color. Grade 2/ Grade1 Braille to be etched/ engraved and be raised 0.5mm above base plate. The signage to be installed at the specified location on the compound wall near the site entrance gate installed at a height of 1200 mm from the finished ground/ floor level, using the necessary hardware specified by the manufacturer and to be installed complete as per design / specifications and guidelines as per the entire satisfaction of the Engineer-in-charge (NS)

3

42711

14237

... More
Providing and fixing acrylic multilingual Braille (raised dots) DIRECTIONAL SIGNBOARDS of size 6` x 9` designed as per accessibility standards and having 3mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devanagari non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non-glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL complete as per design / specifications and guidelines as per the entire satisfaction of the Engineer-in-charge (NS)

100

124600

1246

... More
Providing and fixing acrylic multilingual Braille (raised dots) signboards (DOOR SIGN BOARDS) of size 6`x 9` /12” x5”for room titles, designed as per the drawings issued and having 3mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devanagari non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL complete as per design / specifications and guidelines as per the entire satisfaction of the Engineer-in-charge (NS)

250

315750

1263

... More
Providing and fixing of SS, non-glare Signage board (2 ft. x 2 ft.- 1 no.) for the accessible parking, as per the approved design and make, having 1.2mm thick SS non glare base plate and Grade 2/ Grade 1 Braille (raised dots)to be etched/ engraved and be raised 0.5mm above base plate and Upper Case San Serif words and Universal Accessibility Symbol to be etched/ engraved and signage to be installed at a height of 2100mm from the ground level using a post of MS hollow square section (50mm x 50mm) as per the installation procedure specified by the manufacturer and as per accessibility standards complete as per design / specifications and guidelines as per the entire satisfaction of the Engineer-in-charge (NS)

3

57204

19068

... More
Providing and fixing of high intensity reflective conspicuity tape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3M or equivalent brand complete in all respect to the entire satisfaction of Engineer-in-charge (NS)

1300

328900

253

... More
Providing and fixing 50mm wide colour contrast `EDGE STRIPS` self addhesive on treads of stair cases to help people with visual diabilities and elederly even in dim light condition complete in all respect to the entire satisfaction of Engineer-in-charge (NS)

1300

110500

85

... More
Providing and fixing acrylic/ Aluminium Braille indicators for handrails of the approved design and make having Braille dots raised above base plate, to be installed at the specified locations as per the directions of the engineer in charge complete as per design / specifications and guidelines as per the entire satisfaction of the Engineer-in- charge (NS)

320

113920

356

... More
Providing and fixing retro-reflective information SIGNAGES to provide clear information about the the building/institute in English/Hindi languages clearly visible, readable, understandable , with Type XI Retro-Reflective Sheeting as per ASTM standard and appropriate level,made of 3mm thick ACP sheet with border of 50mm dia round pipe and supported with 200mm dia round piprs of 10-gauge fixed in the gate pillers properly designed M-20 grade cement concrete completein all respect as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge (NS) (Size 6 Mtr. X 1.22 Mtr.)

1

83051

83051

... More
Providing and fixing of Pictorial layout plan of size 900mm x 600mm as approved design, made of 3mm thick acrylic non glare base plate and non glare cut out symbols with grade One Braille on which individual facility points, like inquiry, reception, restrooms, medical room / first aid, cafeteria or breakout area, lounge, meeting room, conference room etc. present the respective floors with pictograph wherever needed all in tactile raised by minimum of 1 to 2mm in various colours to make it legible for seniors, partial vision impaired etc. All the facility names should be in Braille, along with English or Hindi. The entire block of tactile signs should be mounted on wall or on a slant/inclined frame for easy reading. The map to be installed at specified locations and installed at a height of 800mm from ground level complete in all respect as per Harmonized guideline and satisfaction of Engineer in charges.(NS)

5

144070

28814

... More
Recovery of Excess quantity of sand gravel of various sizes received after excavation of basement and other building portion incuding loading, unloading, vertical lead, Horizontal lead, stacking lead and transportation of any lead including royalty and all clearence , statuory permission will be obtained by the contractor/ agencies from mining or other departments. the total expenditure on this account will be totally born by the contractor/agencies complete in all respect. Note:- Excess qty of excavated soil is to be shifted/ sold by the agency and complete required qty of earth are to be kept at site by the agency. it is also made clear that if the excess qty of excavated material / soil lifted by the agency and if required at site the contractor / agency will supply the qty of excavated material/ soil with free of cost at any time.

31178

-11237174

360.42

... More
Providing and Fixing Clay Façade Paneling system in approved shade, finish, size and in thickness of 15mm. The clay panels shall have Flexural Strength /Modulus of rupture = 9 N /mm2 in accordance to IS 15622:2017 E = 0,08 PERCENT (GROUP B IA) (CLAUSE 6) with breaking strength = 550 N in accordance to IS 5622:2017. The panels should have water absorption = 4 % in accordance to IS 13630. The surface scratch hardness value i.e., Moh’s scale should be Minimum 6 in accordance to IS 15622:2017 The clay panels should have inherent properties of being resistant to stains and chemicals. The material should be Class I material in terms of reaction to fire in accordance to EN 13501-1 / ASTM E136. The entire system should be certified by an approved third-party structural consultant for a minimum structural proof load test with positive and negative wind pressure of 5kPA. The entire system shall weight approximately 35 kg per SQM.The cladding panels shall be fixed on to existing cured plastered surface substrate wall treated with one or two coats of primer with appropriate Aluminium rectangular hollow section vertical members framework of 25mm X 50mm (2mm thick) which shall be spaced out in accordance to the dimensions of the panel with minimum spacing of 600mm. The framework shall be attached through L shaped aluminium connectors of 25mm X 37mm (2mm thick) to the substrate walls. The manufactured panels shall have an evenly controlled factory – made groove for resting on to a continuous aluminium rail profiles throughout their length. The profiles are designed and manufactured for starter piece, intermediate and an inverted starter profile for the top piece. Aluminium rail profile shall ensure uniform and precision joints and shall be factory finished with Super Durable powered coated colour in approved RAL shade. All fixtures, and screws shall be corrosion free i.e., all rail profiles, cleats to be used should be made of 6063 T6 alloy grade and all screws used should be of Stainless steel of M/s Hilti, Worth, Klimas, Patta or equivalent. The groove of the width can be chosen i.e., 1.7mm, 3mm, 6.5mm, 12.6mm or 20mm. The corners junctions to be neatly treated with adequate aluminium closed ‘L’ corner shaped pieces in required length in similar shade coated with factory finished Super Durable Powder, to the clay façade panel. Alternatively, the corners junctions can be treated as regular corner fixing or Mitred corner fixing. All fixing details and drawings to be provided by vendor and to be duly approved by Engineer in charge at project and the work to be carried out as per direction of the Engineer- in charge. All fixing details and drawings to be provided by vendor and to be duly approved by Size : 600x1200mm and colour approved as per direction of Engineer in charge at project.(MAKE:- UNISTONE or EQUIVALENT)

7750

50142500

6470

... More
Providing and fixing of C.P. brass large Soap Dish of jaquar make model: ACN-CHR-1131N or equivalent to the satisfaction of engineer-in-charge fixed with C.P. brass screws complete in all respects.

15

10470

698

... More
Supply, installation, testing and commissioning liquid manual soap dispenser with stainles steel lid of jaquar make model: ACN-CHR-1135N or equivalent to the satisfaction of engineer-in-chargeand brackets fixed to wooden cleats with C.P. brass screws.

77

93940

1220

... More
Providing and fixing C.P. cast brass towel ring of jaquar make model: ACN-CHR-1121BN or equivalent to the satisfaction of engineer-in-charge fixed with C.P. brass screws complete in all respects.

92

81972

891

... More
Providing and fixing C.P. brass Shower arm with flange 12 inches round and Overhead Shower round 4 inch of jaquar make model: SHA-CHR-479L300S (ARM) and OHS-CHR-1989 (ROSE) or equivalent to the satisfaction of engineer-in-charge complete in all respects.

8

15800

1975

... More
Providing and fixing in position manhole cover and frame of required shape and approved quality to the satisfaction of engineer-in-charge (make: NTC or equivalent).

100

215800

2158

... More
Supply, erection, testing and commissioning of solar water heating system with following details and complete to the satisfaction of engineer-in-charge (brand as approved make of list). : System temperature output : 60 degree C (during clear sunny days) System type : Thermo syphon System : Non Pressurised Application : Bathing / Washing / Cooking Type of Solar Collectors : Copper tube Flat Plate Collectors as per BIS with following specifications - Size of Collector : 2080 x 1070 x 100 mm Number of Collector : To suit system requirement. Absorber area : 2 sq M Type : Cu - Cu Weight : 46 Kg (Dry) Absorber Coating : Selective - NALSUN Absorbivity : ) 0.95 Emissivity : ( 0.2 Frame Material : 16 SWG extruded Aluminium Glazing : Toughened Glass Glass beeding : EPDM Finish : Painted by approved shade Electrical element Hot water return pump Hardware : SS 304 Insulation : PUF Collector Stand : 35x35x3 mm MS angle `Hot Water Tank : Cylindrical - vertical / horizontal, Stainless steel 304 grade with 100 mm thick Rock Wool insulation including 22 SWG aluminium cladding. ` The entire system should be complete with internal piping in SS(316) with 50 mm rock wool insulation of density 48 kg/m3 with 26 SWG Al cladding, necessary isolation valves, Y type CI strainer, hardwares, temperature gauge of range 0 - 120oC, water meter, MS angle iron structure of min thickness 3 mm duly painted etc as required to complete the system in all respects. The entire system should be approved by BIS as per IS : 12933 and as per local regulations. System Capacity : 1000 liters (storage tank of 1,000 (SS316) litres ) per day (LPD) having 10 collectors.

1

415377

415377

... More
Providing and fixing fully automatic photoelectric cell operated No-touch urinal flushing system (Battery/electrical operated vandal proof- twin flush (pre and post use) operation), flush mounted sensors of jaquar make model: SNR-STL-51087 or equivalent to the satisfaction of engineer-in-charge complete in all respects in fully operational conditions

46

363998

7913

... More
Providing, fixing, testing and commissioning of motorised butterfly valve of 50mm dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 2 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc. complete to the satisfaction of engineer-in-charge (brand as approved make of list).

2

50360

25180

... More
Providing and fixing of curved shaped urinal partition with frosed glass (8mm) size 900 x 450 mm complete with brackets bolts nuts for grouting to wall of jaquar make model: JSE-CHR-810UC450X or equivalent to the satisfaction of engineer-in-charge complete in all respects.

35

157010

4486

... More
Providing and Fixing of Single Lever Basin Mixer Without Pop Up Waste System with cartridge with hot water limiter : manual closing action should Comprises: mounting accessories for single-hole installation and with technical data of jaquar make model: FLR-CHR-5001B or equivalent to the satisfaction of engineer-in-charge.

107

310835

2905

... More
Providing, fixing, testing and commissioning of CP brass swan neck wall mounted mixer with wall flange and swinging casted spout complete as required and making good the walls wherever required of jaquar make model: FLR-CHR-5167NB or equivalent to the satisfaction of engineer-in-charge (for sink).

8

26952

3369

... More
Providing and fixing of clamps for support of pipes at ceiling level of below mentioned sizes complete to the satisfaction of engineer-in-charge (brand as approved make of list).

200

22400

112

... More
Providing and Fixing of stainless steel fully automatic `No Touch` hand drier suitable to operate on 220 volts, single phase 50 hz., A.C. power supply of jaquar make model: HDR-SSF-AK2803D or equivalent to the satisfaction of engineer-in-charge .

48

366096

7627

... More
Providing and Fixing of wall mounted 1 nos S.Steel Grab Rail (629 mm),32mm Dia. ncluding cutting and making good the walls of jaquar make model: WAC-SAP-BR0600CS or equivalent to the satisfaction of engineer-in-charge.

11

68563

6233

... More
Providing and Fixing ofwall mounted 1 nos Disabled GRAB BAR VERTICAL SWING, SATINincluding cutting and making good the walls of jaquar make model: WAC-SAP-BG0800CS or equivalent to the satisfaction of engineer-in-charge .

11

168630

15330

... More
Providing and fixing of S.Steel Paper Dispenser (Capacity: 300 - 350 Paper Towels) fixed with C.P. brass screws complete in all respects of jaquar make model: HDR-SSFAK2803D or equivalent to the satisfaction of engineer-in-charge.

48

289920

6040

... More
Providing and fixing C.P brass 3 INLET SINGLE LEVER DIVERTER with EXPOSED PARTS For Overhead Shower Complete With Wall Flange complete in respects of jaquar make model: ALD-CHR-193 (CONCEALED) and FLR-CHR-5193K (EXPOSED) or equivalent to the satisfaction of engineer-in-charge.

8

41176

5147

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). PLAIN Y 160

40

23440

586

... More
Providing and fixing Towel rail (600mm long) with brackets fixed to wooden cleats with C.P. brass screws of jaquar make model: CAN-CHR-1111SM or equivalent to the satisfaction of engineer-in-charge.

48

56736

1182

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). PLAIN Y 110

71

15265

215

... More
Providing and fixing Towel Rack (600MM LONG WITHOUT HANGERS STAINLESS STEEL) with brackets fixed to wooden cleats with C.P. brass screws of jaquar make model: CAN-CHR-1181FS or equivalent to the satisfaction of engineer-in-charge.

48

100416

2092

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). PLAIN T

135

60750

450

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). PLAIN T 110

250

39500

158

... More
Providing and fixing C.P. cast brass twin coat hooks fixed to PVC rawl plug with SS screws including cutting and making good the walls.and as per the direction of Engineer-in-charge of jaquar make model: ACN-CHR-1161N or equivalent to the satisfaction of engineer-in-charge.

15

7245

483

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). PLAIN T 75MM

40

3480

87

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). CLEAN OUT 160

20

7920

396

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). CLEAN OUT 110MM

40

6720

168

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). DOOR T 160

120

58200

485

... More
Providing and fixing uPVC inlet fitting (Hopper) maximum with 2 or 3 inlets of 40 to 63 mm OD size fabricated from 110 OD uPVC pipe fixed to uPVC trap jointing with solvent cement joint and set in a cement concrete 1:2:4 mix complete including cost of cutting and making good the walls and floors wherever required to the satisfaction of engineer-in-charge (brand as approved make of list).

124

19220

155

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). DOOR T 110

165

34485

209

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). REDUCER Y 110

100

19200

192

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). REDUCER DOOR T 160

70

51870

741

... More
Providing and fixing uPVC N-Trap with u all fitting and accessories fixed in cement mortar complete in all respect to the satisfaction of engineer-in-charge (brand as approved make of list).

36

5256

146

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). END CAP 160MM

500

97500

195

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). END CAP 110

500

56500

113

... More
Providing and fixing of epoxy coated MS. Grating with frame for channel drains including all accessoreis complete to the satisfaction of engineer-in-charge (brand as approved make of list). 200MM WIDE

125

181375

1451

... More
Providing and fixing of uPVC Waste pipes 6 kg/cm2 (IS: 4985:2000) including with all fittings e.g. couplings, tees, bends, reducers and screwed adoptors jointing with solvent cement as per Manufacturer`s specifications complete including cutting holes or chases in wall and making good the same wherever required to the satisfaction of engineer-in-charge (brand as approved make of list). (Waste pipe from fixtures). 50MM

85

15045

177

... More
Providing and fixing of uPVC Waste pipes 6 kg/cm2 (IS: 4985:2000) including with all fittings e.g. couplings, tees, bends, reducers and screwed adoptors jointing with solvent cement as per Manufacturer`s specifications complete including cutting holes or chases in wall and making good the same wherever required to the satisfaction of engineer-in-charge (brand as approved make of list). (Waste pipe from fixtures). 40MM

125

15125

121

... More
Providing and fixing heavy duty square stainless steel grating (size 125x125) with hinged cockroach trap to the satisfaction of engineer-in-charge (brand as approved make of list).

160

117600

735

... More
For Domestic Water Supply at at Terrace Level Supplying and supervision of testing and commissioning of Booster Pumpset (Hydropneumatic systems) as described below . Supplying and supervision of testing and commissioning of package vertical Hydropneumatic system, comprising of 2.0 nos. (1 duty plus 1 stand by) Electrical Driven inline pumping sets each of 2.5 LPS to a head to 25 meter with all accessories, Pumps shall be with C.I. Base, S.S 304, impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common channel baseplate 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, pressure switch, common suction and delivery header, bellows on sucton and delivery side complete in all repsects. (Make: Lubi/Ebara/Grundfoss) Pump mounted or wall mounted microprocessor based controller, Electronic control panel with frequency inverter, logic controller relays, pressure sensor, pressure sensor transmitter, electrical wiring, cabling from panel to pumps, level controller, two lined LCD display, diodes to indicate pump ready, pump running and fault capable to communicate with toher RS 485 interface. with Power box equipped with fuses or isolators or circuit breakers as required. complete with all accessories as per manufacturer specifications. Suction and Delivery Header - SS 304 Control Valve On suction and Delivery - Ball Valve Only (No Butterfly Valve Accepted). Flow Prevention - Only Check Valve Impeller : Stainless Steel Shaft : Stainless Steel RPM : 2900. Mover : Electric Motor HP - As required. Necessary foundation with bolts Ball valve on suction and delivery Including all electrical panel and cabling works. NRV on delivery Dust and vermin proof cubicle type motor control centre fabricated from powder coated 16 SWG MS sheet suitable to automatic working of above mentioned pumps. 1 No. -100 ltr Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete.

1

272922

272922

... More
Supply, installing, testing and commissioning of submersible dewatering single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller, SS-304 shaft connected to TEFC submersible motor for 415 plus 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps running together in case of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects. (Make: Lubi/Ebara/Grundfoss) (Pumps shall be installed in a set of two pumps One working and One Assist) Pump Room Drainage Pumps and basement (Pumps to be suitable to handle solids upto 30 mm size) Capacity - 4.0 LPS (Each) Head - 22.5 M H.P. - 2.5 HP Approx.

3

441072

147024

... More
Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts. All switchboards shall have provision for entry of cables from the top or bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position. PANEL SHOULD BE WITH ALL WIRING, CABLES, TRANCHES, HANGERS AS REQUIRED IN PUMP ROOMS TO THE SATISFACTION OF ENGINEER-IN0CHARGE Electric Panel For Water Supply Pumps at Water Supply Pump Room INCOMING 1 No. 80 amps TP plus NL MCCB with the following accessories: 1 No. square flush mounting 0-500 volts scaled voltmeter with three way and OFF switch. Three phase indicating lights. Electrolytic high conductivity three phase and neutral tinned alluminium bus bar rated at 300 amps having a current density of 1 amp per Sqmm suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The neutral bus bar is to be of 100% capacity. OUTGOING UNITS 2 Nos 32 Amp. TPN MCB of breaking capacity 10KA 4 Nos 63 Amp. TPN MCB of breaking capacity 20KA 1 No. TPN MCB of 100 A with 20 KA service breaking capacity for Domestic water hydropneumatic pumps (Only connection to inbuilt panel of Domestic system) 6 Nos. fully automatic DOL starters with push buttons and ON/OFF indicating lights and overload relays for 2.0 to 7.5 HP pumps. 6 Nos. selector switch for selecting mode of operation i.e. auto/manual/off. 6 Nos.cyclic relay for automatic duty changeover of pumps. 6 No. single phase preventors. 6 Nos. square flush mounting 0-30 amps scaled ammeters with three way and OFF selector switch. Space for 3 Nos. Level Controllers. Switchgear shall be suitable for the HP of various motors. 2 No.40 Amp. TPN MCB Spare. 2 No. 32 Amp. TPN MCB Spare. The motor control panel shall be prewired with colour coded wires with identification labels complete in all respects as required.

1

261502

261502

... More
Providing and fixing Rubber carpet flooring Top layer:- EPDM plus recycled rubber Bottom Layer:- recycled rubber , random mixed color Dimension 500x500m having thickness 20mm application on Gym, Playground area installation with connectors as per approved manufacturers. Physical performance : 1. Slip resistance : 0.3µ 2. Sliding Properties: R10 3.Maximum fall height: 0.85m (20mm tiles) 4.Shock absorption : 50.7% (20mm tiles) 5 Vertical deformation : 2.6mm (20mm tiles) 6 Impact Sound Improvement Rating : 25dB (20mm tiles) Chemical performance : 1 Resistance to Chemicals : No change in surface 2 Fire rating : Efl All complete as per direction of Engineer –in- charge.

88.6

354045

3996

... More
Providing and Fixing of GRC Moulding sizes as per drawing and details fixing with the help of the screws and adhesive as per direction of Engineer-in Charge. (MAKE:- UNISTONE, NTC, GRAND) 600 Wide 250mm thk solid Moulding

261.61

1659392

6343

... More
Providing and Fixing of GRC Moulding sizes as per drawing and details fixing with the help of the screws and adhesive as per direction of Engineer-in Charge. (MAKE:- UNISTONE, NTC, GRAND) 900 Wide 250mm thk solid Moulding

456.4

3895374

8535

... More
Providing and Fixing of GRC Moulding sizes as per drawing and details fixing with the help of the screws and adhesive as per direction of Engineer-in Charge. (MAKE:- UNISTONE, NTC, GRAND) 450 Wide 250mm thk solid Moulding

291.68

1513819

5190

... More
Providing and Fixing of GRC Moulding sizes as per drawing and details fixing with the help of the screws and adhesive as per direction of Engineer-in Charge. (MAKE:- UNISTONE, NTC, GRAND) 250 Wide 250mm thk solid Moulding

110.44

382122

3460

... More
Providing and fixing soft fiber acoustical false ceiling square edged tiles astra at all heights of size 595X595X15/20 mm. The tiles should have Humidity Resistance (RH) of 90%, thermal insulation = 0.5 (m² k / w) and moisture rate = 1% (JC/T670 – 2005), light Reflectance of )85%, and fire retardant as per Class A in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.30 mm thickness (galvanized @120 gsm) comprising main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle ofsize24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centreand 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 15 mm thick micro-look soft fiber white false ceiling tile (NRC 0.9 to 1) Make: Credence/Ecophon/Topakustik

313.58

570715

1820

... More
Providing and Fixing Dormakaba pull Handle TGDI-H 450 back to back with 350mm CTC or equivalent , adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface. Length =450mm, 25mm dia, -SS304, complete as per direction of Engineer-in-Charge.

402

1218060

3030

... More
Providing and Fixing Dormakaba pull Handle TGDI-H 600 back to back with 500mm CTC or equivalent , adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface. Length =600mm, 32mm dia, -SS304, complete as per direction of Engineer-in-Charge.

146

683718

4683

... More
Providing and fixing Dormakaba Mortice dead lock 706 or equivalent with 55mm backset, 20mm square forend prepared for euro profile cylinder including strike plate in satin stainless steel. Complete with EPC 60mm Length both side key operation and Escutcheons in SSS Finish. complete as per direction of Engineer-in-Charge.

320

623360

1948

... More
Supply and Fixing dormakaba 9117711 or equivalent Surface Mounted Tower bolt of Length 18` in SS finish with fixing accessories as per direction of engineer-in-charge.

852

1007916

1183

... More
Supply and Fixing dormakaba 9117713 or equivalent Surface Mounted Tower bolt of Length 12` in SS finish with fixing accessories as per direction of engineer-in-charge.

852

667116

783

... More
Providing and fixing Dormakaba SR-390 or Equivalent Surface mounted door coordinator for double doors , zinc plated for steel doors, non-Handed as per EN1158 and CE marked as per direction of Engineer-in Charge. Fire Rated 2hrs.

99

721215

7285

... More
Providing and fixing dormakaba rack and pinion door closer TS 71 or equivalent with adjustable closing force, size EN 3 or 4, Std. Arm closing speed adjustable in two independent ranges, with adjustable latching action. Non-handed. Approved to EN 1154,CERTIFIRE and CE Marked. Durability - 500,000 Cycles, Corrosive resistance - Moderate,Finish:Silver as per direction of Engineer-in Charge. Fire Rated 2hrs.

212

928984

4382

... More
Providing and fixing Dormakaba 3108 or equivalent floor stop half dome with 45mm dia with fixing accessories, in satin Chrome as per direction of Engineer-in-Charge.

841

219501

261

... More
Providing and fixing dormakaba pull Handle TGDI-D 300 or equivalent back to back with adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface.CTC - 300mm, 22mm dia, Material - SS304, as per direction of Engineer-in-Charge.

14

23380

1670

... More
Providing and fixing dormakaba Mortice dead lock 288a or equivalent with 55mm backset, 20mm square forend and prepared for euro profile cylinder including strike plate in satin stainless steel as per EN 12209, CE marked. Complete with EPC 70mm Length both side key operation and Escutcheons in SSS Finish.as per direction of Engineer-in-Charge. Fire Rated - 2 Hours.

14

54670

3905

... More
Providing and Fixing dormakaba PHCR1000 1 plus 2 point locking plus PHCRT 2905 plus 3006 or equivalent Panic bar (Triple Point ) set for active leaf and 2 point locking panic bolt set on inactive leaf suitable for door width and height complete set with screws and fixing accessories Trim lever Latch Complete set including Spindle, screws and all fixing accessories 6 pin Euro profile half cylinder with one side key operation standard length 42mm in satin nickel plated finish with 3 keys. Optional master keying and grand master keying can be done on request. reputed brand and manufacture.as per direction of Engineer-in Charge. Fire Rated 2hrs.

99

2034450

20550

... More
Grouting the joints of floor tiles having joints of 4 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 800x800mm

1093.8

144381

132

... More
Grouting the joints of floor tiles having joints of 4 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 1000x1000 mm

6432

611040

95

... More
Providing and fixing white color vitreous China flat back, above counter wash basin of jaquar make model: JDS-WHT-25909 or equivalent to the satisfaction of engineer-in-charge with R.S. or CI bracket and 32 mm dia outlet, with brass C.P. wall cap and extension pieces, 15 mm dia C.P. brass angle stop cock with 10mm dia C.P. brass connection pipe etc. CP brass chain, CP wall flange, rubber adopter for waste connection complete, CP brass chain CP waste and CP pipe to wall with CP wall flange and rubber adopter for waste connection complete, with pedestal of matching model below wash basin, including cutting and making good the walls wherever required.

92

567732

6171

... More
Providing and fixing in position manhole cover and frame of required shape and approved quality to the satisfaction of engineer-in-charge (make: NTC or equivalent). 600x600 - MD10

100

215800

2158

... More
Providing and fixing in position manhole cover and frame of required shape and approved quality to the satisfaction of engineer-in-charge (make: NTC or equivalent). 300x300 - LD-2.5

50

37750

755

... More
Providing, laying, testing and commissioning of `B` class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with twoor more coats of synthetic enamel paint of required shade complete as required to the satisfaction of engineer-in-charge (brand as approved make of list). 65 mm dia nominal bore

50

23450

469

... More
Providing, laying, testing and commissioning of `B` class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with twoor more coats of synthetic enamel paint of required shade complete as required to the satisfaction of engineer-in-charge (brand as approved make of list). 80 mm dia nominal bore

150

87000

580

... More
Providing, fixing, testing and commissioning of full way level operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not lass than 15 kg/sq.cm with threaded/flanged complete with nuts, bolts, gaskets, washers etc. as required complete to the satisfaction of engineer-in-charge (brand as approved make of list). 15 mm NB

18

6300

350

... More
Providing, fixing, testing and commissioning of full way level operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not lass than 15 kg/sq.cm with threaded/flanged complete with nuts, bolts, gaskets, washers etc. as required complete to the satisfaction of engineer-in-charge (brand as approved make of list). 20 mm NB

22

10648

484

... More
Providing, fixing, testing and commissioning of full way level operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not lass than 15 kg/sq.cm with threaded/flanged complete with nuts, bolts, gaskets, washers etc. as required complete to the satisfaction of engineer-in-charge (brand as approved make of list). 25 mm NB

20

15000

750

... More
Providing and fixing of clamps for support of pipes at ceiling level of below mentioned sizes complete to the satisfaction of engineer-in-charge (brand as approved make of list). swivel hanger 25mm

200

22400

112

... More
Providing and fixing of clamps for support of pipes at ceiling level of below mentioned sizes complete to the satisfaction of engineer-in-charge (brand as approved make of list). swivel hanger 32mm

225

27000

120

... More
Providing and fixing of clamps for support of pipes at ceiling level of below mentioned sizes complete to the satisfaction of engineer-in-charge (brand as approved make of list). swivel hanger 40mm

150

18300

122

... More
Providing and fixing of clamps for support of pipes at ceiling level of below mentioned sizes complete to the satisfaction of engineer-in-charge (brand as approved make of list). swivel hanger 50mm

175

21875

125

... More
Providing and fixing of clamps for support of pipes at ceiling level of below mentioned sizes complete to the satisfaction of engineer-in-charge (brand as approved make of list). swivel hanger 65mm

185

27750

150

... More
Providing and fixing of clamps for support of pipes at ceiling level of below mentioned sizes complete to the satisfaction of engineer-in-charge (brand as approved make of list). swivel hanger 80mm

275

44825

163

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). COUPLER 160 mm

322

74704

232

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). COUPLER 110 mm

664

53120

80

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). BEND 87.5 160 mm

95

30210

318

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). BEND 87.5 110 mm

69

8763

127

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). REDUCER 160 X 110MM

40

9440

236

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). REDUCER 110 X 75mm

180

16920

94

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). REDUCER Y 160 X 110 mm

40

22440

561

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). REDUCER Y 110 X 75 mm

100

19200

192

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). REDUCER DOOR TEE 160 X 110 mm

70

51870

741

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). REDUCER DOOR TEE 110 X 75 mm

120

24840

207

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) moulded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). REDUCING BUSH 110 mm

250

25750

103

... More
Providing and fixing vent cowl complete in all respect to the satisfaction of engineer-in-charge (brand as approved make of list). 160 mm dia

20

1440

72

... More
Providing and fixing vent cowl complete in all respect to the satisfaction of engineer-in-charge (brand as approved make of list). 110 mm dia

10

270

27

... More
Providing and fixing of cleanout plug, fixed to UPVC Pipe with push joint complete in all complete including cutting and making good the walls and floor wherever required - 160 mm dia

12

4752

396

... More
Providing and fixing of cleanout plug, fixed to UPVC Pipe with push joint complete in all complete including cutting and making good the walls and floor wherever required 110 mm dia

120

20160

168

... More
Providing and fixing UPVC, P or S trap of self cleaning design with / without vent arm setting in cement concrete 1:2:4 mix complete including cost of cutting and making good the wall and floors wherever required to the satisfaction of engineer-in-charge (brand as approved make of list). 110 mm inlet and 110 mm outlet

124

37448

302

... More
Supply Installation,Testing and Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, (minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class `C` face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete including CC foundation of suitable size complete with brand as approved to the satisfaction of engineer-in-charge. Dual Media Filter For Domestic Water Supply Capacity- 2.0 LPS Filter dia approx. - 1400 MM Working pressure: 5.0 Kg/sq cm. Test pressure : 7.0 Kg/sq cm

1

77080

77080

... More
Supply Installation,Testing and Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, (minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class `C` face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete including CC foundation of suitable size complete with brand as approved to the satisfaction of engineer-in-charge. Activated Carbon Filter For Domestic Water Supply Capacity- 2.0 LPS Filter dia approx. - 1400 MM Working pressure: 5.0 Kg/sq cm. Test pressure : 7.0 Kg/sq cm

1

85074

85074

... More
Supply Installation,Testing and Commissioning of Water Softener fabricated from MS plate as per IS: 2825 (minimum thickness of shall 6 mm and dished end 8 mm) complete with initial charge of resins , GI class `C` face piping, CI butterfly valves, pressure gauge, hydraulic brine injector, accessories, painting inside with epoxy paint, including 500 liters capacity PVC / HDPE brine tank suitable for 2 regeneration capacity, testing and commissioning complete with resins of approved quality and make complete in all respects including CC foundation of suitable size complete with brand as approved to the satisfaction of engineer-in-charge. For Domestic Tower Water Supply in Water Supply Pump Room Hardness- Inlet- 500-600 PPM Outlet- Less than 50 PPM Capacity- 2.0 LPS Regeneration period 12 hrs. Working pressure: 5.0 Kg/sq cm. Test pressure : 7.0 Kg/sq cm

1

176999

176999

... More
Supply Installation,Testing and Commissioning of metering pump type chemical doser with 200 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-12 lph, complete in all respects complete with brand as approved to the satisfaction of engineer-in-charge. Chlorination of Domestic Water

1

25122

25122

... More
Supplying and fixing of float based visual flow meter (Rotameter) suitable for water flow rate of 7200 litres per hour in the input line of water softener including matching flanges, nuts, bolts and 3 mm thick rubber insertions/gaskets complete. to assess the water flow rate in water softener complete with brand as approved to the satisfaction of engineer-in-charge.

1

22724

22724

... More
Providing and fixing C.P. brass Concealed Stop Cock of jaquar make model: FLR-CHR-5083NK (EXPOSED) and ALD-CHR-083 (CONCEALED) or equivalent to the satisfaction of engineer-in-charge for basin mixer and geyser points of approved quality conforming to IS:8931 (for single toilet maintenance) 15 mm nominal bore.

15

20910

1394

... More
Powder Coating on Aluminium Fittings

3138

72174

23

... More
Providing and fixing Foam Jet Bubbler Type Fountain with 13 nozzles with 10HP 3 phase Motor with control panel (Make Kirloskar, Crompton) including all civil and electrical works complete as per direction on Engineer-In-Charge.

1

953839

953839

... More
Extra for providing toughening to 6mm glass complete in all respects as per manufacturer`s specifications and as per the directions and entire satisfaction of Engineer-In-Charge.

1903

633699

333

... More
Providing and fixing SS railing with circular handrail of dia 35-45 mm at two levels i.e. 700 mm and 900 mm respectively, should extend 300mm and 450 mm after the stair ramp runs in staircase (NS)

250

85250

341

... More
Supplying and fixing GRC paving tiles Pattern : Cobble stone Size 152x152x22mm Variation upto 2mm Heavy duty laid in any pattern as specified over a base of 20mm thick cement sand mortar 1:3 complete in all respect as per direction of Engineer-in Charge.(MAKE:- UNISTONE or Equivalent)

214

225770

1055

... More
Raw Water Treatment Feed Pump set Providing, fixing, commissioning and testing package vertical raw water pumps (1 working plus 1 stand by), comprising of Electrical Driven inline pumping with all accessories, Pumps shall be with C.I. Base, S.S 304, impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common channel baseplate 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, pressure gauge bourden type, common suction and delivery header, bellows on suction and delivery side complete in all resects to the satisfaction of engineer-in-charge. (make: Lubi/Ebara/Grundfoss) Pumps shall be suitable for 415 ± 10% volts 3 phase 50 Hz A.C supply and shall be having the following requirement complete with foundation and associated civil works. Suction and Delivery Header - SS 304 Control Valve On suction and Delivery - Ball Valve Only (No Butterfly Valve Accepted). Flow Prevention - Only Check Valve Suction and delivery header including all pipes, suction and delivery sides valves, NRV, Pressure gauges and accessories complete. Flow Rate : 2.0 LPS Head : 35 M Min. Motor HP : 2.0 H.P. (Each)

1

115449

115449

... More
Domestic Water Transfer Pumps Providing, fixing, commissioning and testing package vertical Hydro pneumatic treated water pumps (1 working plus 1 stand by), comprising of Electrical Driven inline pumping with all accessories, Pumps shall be with C.I. Base, S.S 304, impeller, shaft, mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common channel baseplate 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, pressure guage bourden type, common suction and delivery header, bellows on sucton and delivery side complete in all repsects to the satisfaction of engineer-in-charge. (Make: Lubi/Ebara/Grundfoss) Pumps shall be suitable for 415 ± 10% volts 3 phase 50 Hz A.C supply and shall be having the following requirement complete with foundation and associated civil works. Suction and Delivery Header - SS 304 Control Valve On suction and Delivery - Ball Valve Only (No Butterfly Valve Accepted). Flow Prevention - Only Check Valve Suction and delivery header including all pipes, suction and delivery sides valves, NRV, Pressure gauges and accessories complete. 1 Nos. -200 ltr Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete. Flow Rate : 4.5 LPS Head : 60 M Min. Motor HP : 7.5 H.P. (Each)

2

369986

184993

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) molded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). BEND 45 DEG 110mm dia

85

8075

95

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type -`B`) molded fitting for soil, waste and vent pipes conforming to IS: 14735 making good the same to the satisfaction of engineer-in-charge (brand as approved make of list). bend 45 160mm dia

85

24310

286

... More
Providing First aid box

3

8400

2800

... More
Single Line Diagram framed in 1000 x 800 mm size glass frame

2

5000

2500

... More
Providing and fixing of Fire Bucket stand made of M S angle suitable for and with 4 Nos Fire Buckets of 9.5 Ltrs capacity

3

7800

2600

... More
Providing Rubber gloves of 11 KV grade

4

10000

2500

... More
Shock Treatment Chart

2

2800

1400

... More
Supply and erection of mat made of elastomeric polymers Material (Class A )1.2 M wide with 2 mm thickness to withstand 1.1 KV dielectric strength

35

126000

3600

... More
Supply and erection of Safety mat made of elastomeric polymers Material (Class B) 1.2 M wide with thickness 2.5 mm to withstand 12KV dielectric strength

10

42000

4200

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm plus 2 X 6 sq. mm earth wire Inside the building premises

260

169000

650

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm plus 2 X 6 sq. mm earth wire

2160

1872720

867

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm plus 2 X 6 sq. mm earth wire

2160

2542320

1177

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

500

20500

41

... More
Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following capacity BUS DUCT for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq. cm at nominal current rating, necessary joints, elbow joints and expansion joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required (From TRX to Change over Panel and From DG Synch Panel to Change Over Panel) 1600 A

50

1145350

22907

... More
Supplying, installation, testing and commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 630 A Isc = 50kA for 1 second

2

23186

11593

... More
Supplying, Installation, Testing and Commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB (but without MCCB) complete etc. as Required 100/125 A 25kA SC for 1 sec

7

52346

7478

... More
Supplying, Installation, Testing and Commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB (but without MCCB) complete etc. as Required 160/200 A 25kA SC for 1 sec

2

14956

7478

... More
Supplying, installation by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 Phase 4 Wire 415 Volts, 50 Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints and expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adapter box and copper flexibile for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets ,suspenders, angle iron bracket, steel fasteners, connectong to earthing system ect. as required 630 A Isc = 50kA for 1 second

50

828450

16569

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

1500

315000

210

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Ten Loop Panel.

1

392886

392886

... More
Supplying, installation, testing and commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required

1

173022

173022

... More
`Supplying, installation, testing and commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required `

1

93740

93740

... More
`Supplying, installation, testing and commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. `

609

1501185

2465

... More
Supplying, installation, testing and commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.

300

71400

238

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required.DSR-16.8

50

58250

1165

... More
Supplying, installation, testing and commissioning of fault isolator complete with base as required.

45

126900

2820

... More
Providing and Fixing in position the mercury in glass with industrial type thermometers.DSR-16.9

50

44550

891

... More
Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve (UL Approved actuators) with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC ,and upto 20 mA electric signal and providing similar transduced feedback output to control system ,BMS compatable as required DSR-16.11.3.3 -250 mm dia

4

246988

61747

... More
Supplying, installation, testing and commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.

55

129305

2351

... More
Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve (UL Approved actuators) with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC ,and upto 20 mA electric signal and providing similar transduced feedback output to control system ,BMS compatable as required DSR-16.11.3.3 -200 mm dia

1

47228

47228

... More
Supplying, installation, testing and commissioning of addressable fire control module complete as required.

24

62160

2590

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar minimum. The valve shall be BMS compatible, complete as required. DSR-16.11.4.4 80 mm dia.

3

175485

58495

... More
Supplying, installation, testing and commissioning of addressable phone control module complete as required

20

56360

2818

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar minimum. The valve shall be BMS compatible, complete as required. DSR-16.11.4.4 65 mm dia.

10

459610

45961

... More
` Supplying, installation, testing and commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. `

5

315600

63120

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar minimum. The valve shall be BMS compatible, complete as required. DSR-16.11.4.4 50 mm dia.

8

238160

29770

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar minimum. The valve shall be BMS compatible, complete as required. DSR-16.11.4.4 40 mm dia.

10

271580

27158

... More
Supplying, installation, testing and commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.

16

107824

6739

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar minimum. The valve shall be BMS compatible, complete as required. DSR-16.11.4.4 32 mm dia.

15

219375

14625

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar minimum. The valve shall be BMS compatible, complete as required. DSR-16.11.4.4 25 mm dia.

5

68770

13754

... More
Supplying, installation, testing and commissioning of addressable manual call point complete as required.

42

140238

3339

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar minimum. The valve shall be BMS compatible, complete as required. DSR-16.11.4.4 20 mm dia.

15

150420

10028

... More
Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required.

42

127008

3024

... More
Supply, installation, testing and commissioning of opposed blade aluminium volume control dampers with black mat finish in supply air duct collars,Damper shall be with 16G GSS body and blades shall be with aluminium airfoil construction. complete with neoprene rubber gaskets,nuts, bolts, screws linkages, flanges etc. as per approved shop drawings and specifications.

25

150425

6017

... More
Supplying and fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

10

77750

7775

... More
Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required.

2

9902

4951

... More
Supplying, installation, testing and commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.

1

161295

161295

... More
Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications.

15

75705

5047

... More
Supplying, fixing testing commissioning of supply air diffusers (Flat face type) of powder coated and made from extruded aluminium section ,smudge proof with aluminium volume control dampers with anti smudge ring.All extruded aluminium diffusers shall be provided with removable central core and concealed key operation for volume control damper.Complete as required.

30

312120

10404

... More
Supplying, installation, testing and commissioning of fire fighter phone jack complete as required.

20

27600

1380

... More
Supplying, fixing testing commissioning of return air diffusers (Flat face type) of powder coated and made from extruded aluminium section,smudge proof without aluminium volume control dampers with anti smudge ring.All extruded aluminium diffusers shall be provided with removable central core..Complete as required.

30

208050

6935

... More
Supplying, installation, testing and commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required..

1

109026

109026

... More
Supplying, Fixing,testing and commissioning of fire dampers . Actuator shall be UL listed complete as required and as per specifications. DSR-16.20.1 Fire damper(150 mm deep)

25

227550

9102

... More
Supplying, installation, testing and commissioning of 1.5/3/6W ceiling speaker complete as required.

608

505856

832

... More
Supplying, installation, testing and commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

20

30920

1546

... More
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. DSR-16.22

500

539000

1078

... More
Control Panel with actuator(10Nm Torque) and all control and power Wiring

28

237804

8493

... More
Supplying, installation, testing and commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.

1

70513

70513

... More
Supplying and laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring and LSZH outer sheath complete as required.

9000

2790000

310

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5C x 1.5 Sq. mm

120

15960

133

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.

550

229542

417.35

... More
Supplying, fabricating and installing following size of perforated painted with powder coating M.S. cable trays,with perforation not more than 17.5%, in covenient section, joined with connectors, suspended from the ceiling with MS suspenders including bolts and nuts, painting suspenders etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness

40

18760

469

... More
Supplying, fabricating and installing following size of perforated painted with powder coating M.S. cable trays,with perforation not more than 17.5%, in covenient section, joined with connectors, suspended from the ceiling with MS suspenders including bolts and nuts, painting suspenders etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

30

20100

670

... More
Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

6

55668

9278

... More
`Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. `

2

12888

6444

... More
`Supplying and laying 25 mm x 5 mm. G.I. strip in 40 mm dia. G.I. Pipe from earth electrode, including connection with GI nut, bolt, spring, washer excavation and re-filling etc as required. `

40

24360

609

... More
`Providing and fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required. `

110

23100

210

... More
`Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required. `

180

6480

36

... More
Laying and fixing o f one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

25

1175

47

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. `Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) `

265

34980

132

... More
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 16 sq. mm. Armoured Aluminium cable.

20

4660

233

... More
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tool with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 35 sq. mm. Armoured Aluminium cable.

60

19080

318

... More
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 120 sq. mm. Armoured Aluminium cable.

20

10560

528

... More
FIRE PUMPS - ELECTRICAL `(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.` (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz , AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 88 m Head

1

344568

344568

... More
FIRE PUMPS - ELECTRICAL `(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.` (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 1620 lpm at 56 m Head

1

242760

242760

... More
FIRE PUMPS - DIESEL `a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Drive Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.` b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio ndications, painted with post office red colour etc. as required. c) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 88 m Head

1

543025

543025

... More
a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS : 325. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 180 lpm at 88 m Head

1

108576

108576

... More
Fabrication, supply, Insallation testing and commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, ompartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump and diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : INCOMER 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich and CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A OUTGOING. Main fire pump and Sprinkler pump `200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.` Water curtain pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey pump `100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.` Diesel Engine Control Control for Diesel Engine comprising:- Auto / Manual selector switch and 3 attempt starting device, timers and relays as required, push buttons, start / stop in manual mode. Indication lamp for High / Low Lub. Oil pressure, High Water Temp. and Engine ON indication. Battery charger suitable for 12V / 24 V DC with boost and tickle selector switch, 0-30 V DC volt meter, 0-20A DC Ammeter. All standard relays and acessories for automatic operation of diesel engine. DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor switch and 3 attempts starting device, timers and relays as required, push buttons,start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

245810

245810

... More
Providing laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with oaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 nominal bore (class C)

550

1786400

3248

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. 25 mm nominal bore (class C)

7360

4673600

635

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diamete r pipe. Welded joint above 50mm diameter pipe. 32 mm nominal bore (class C)

470

343570

731

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. 40 mm nominal bore (class C)

1120

988960

883

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. 50 mm nominal bore (class C)

1260

1378440

1094

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. 65 mm nominal bore (class C)

870

1198860

1378

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe 80 mm nominal bore (class C)

1255

2019295

1609

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. 100 mm nominal bore (class C)

465

1014630

2182

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. 150 mm nominal bore (class C)

745

2273740

3052

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. 200 mm nominal bore (class C)

25

116625

4665

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground) Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. 250 mm nominal bore (class C)

25

142150

5686

... More
`Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :` Single headed Stainless steel

48

251616

5242

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

10

52420

5242

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia

50

212700

4254

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia

2

11386

5693

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia

82

627382

7651

... More
Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150 mm dia.pipe

13

252681

19437

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

58

65424

1128

... More
Providing, installation , testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80 mm dia

2

13136

6568

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia

2

18872

9436

... More
Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 150 mm dia.

2

19032

9516

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless steel (Grade 304)

116

440568

3798

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following asrequired. `20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585` 20 mm nominal internal dia gun metal globe valve and nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. 30 m

48

355584

7408

... More
Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless steel (Grade 304)

58

82302

1419

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe

1

5757

5757

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe

2

23866

11933

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

2

31158

15579

... More
Providing, fixing, testing and commissioning of 15mm dia uartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :r Upright Sprinkler

2990

1333540

446

... More
Providing, fixing, testing and commissioning of 15mm dia uartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Horizontal side wall sprinkler

202

106454

527

... More
Providing, fixing, testing and commissioning of 15mm dia uartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Concealed sprinkler

2

2450

1225

... More
Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required.

32

42240

1320

... More
Providing and fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm dia

28

215712

7704

... More
`Providing, fixing, testing and commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :` 150mm dia

1

41161

41161

... More
`Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.` 1000mm

5

6735

1347

... More
Supplying, installation, testing and commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required. 80 mm dia

2

142496

71248

... More
Providing, installation, testing and commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.

26

15574

599

... More
Providing, installation, testing and commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required

2

12586

6293

... More
Providing, installation, testing and commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

5

965

193

... More
Constructing masonary chamber 90 x 90 x100 cm. inside with 75 class designation brickwork in cement mortar 1:5 ( 1 cement : 5 fine sand) for sluice valve with CI surface box 100 mm top dia. 180 mm bottom dia. And 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1 :5 :10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size and inside plastering with 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design with FPS bricks

13

228722

17594

... More
Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately) 50 mm dia.

10

44430

4443

... More
Providing and fixing in position wall Panelling at all heights of thickness 25 mm with Fiber Glass Acoustical Wall Panels of size 600x1200 mm creda, resin bonded square edges having NRC of 0.9 minimum. The panels should be manufactured from high density bio-soluble resin bonded glass wool absorber having density of 96 Kgs/m3 and wrapped on the front side with an acoustically transparent fabric having option of colours and fabric options like jute etc. as per approved by architect/engineer-in-charge, plain tissue backer and fabric wrapped hardened edges. Panels should have humidity resistance up to 90 %, thermal conductivity = 0.03 (m² k / w) thermal resistance = 0.9 (m² k / w) and moisture rate = 1% (JC/T670 – 2005). The panel should be fully recycled and fire retardant as per Class A. The installation comprises fixing of 6-8 mm ply board surface on the existing surface to avoid any undulations. Surface impalers having projecting elements called spikes shall be fixed on the plain surface at 1200 mm center to center horizontally and 600 mm center to center vertically or as per approved by engineer-in-charge, using self-tapping screws. Silica based construction adhesive to be dabbed on to the projecting elements (spikes) of the impalers. Wall Panels shall be pierced through the spikes of the impalers ensuring line and level of panel are maintained. The panels should be mounted on the impalers horizontally or vertically as per the approved design or as per the directions of the engineer-in-charge. Make: Credence/Ecophon/Topakustik

353.74

1526741

4316

... More
Design, Construction, Installation, testing and Commissioning of Sewage Treatment Plant of 100 KLD per day capacity based on MBBR technology, followed by ultra filtration plant including all civil, electrical, and mechanical components of suitable capacity with boosting machinery and successful trial run, operation and comprehensive maintenance upto defect liability period of two years from the date of commissioning/handover whichever is later. Before execution, the contractor must submit the detailed working drawings duly vetted by the Public Health consultant and structural engineer finalized by HPHC as per latest norms of HSPCB and one standby pump in each unit of treatment plant in addition to working pumps at the cost of the contractor. Cement concrete pucca path will be provided for interconnection of Civil/Mechanical components. Surrounding area with greens/plants to be provided and maintained by the contractor at his own cost till the defect liability period. Comprehensive maintenance of STP upto Defect Liability period and running of STP through operators will be in the scope of contractor at his own cost. SCOPE:- Raw sewage collection to collection of treated water and its delivery for horticulture work and collection/disposal of dry sludge to the respective area will be in scope of work with the contractor

1

4500000

4500000

... More
Extra for providing grooved grid instead of Plain T Grid

7836.83

843556

107.64



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.