If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Sep 2024
Closing Date17 Oct 2024
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Summary

Ge (i) R And D/chd-72/2024-25 Repair And Maint Of Lt Panels In Zone-i And Ii And Connected Works In Tbrl Range Ramgarh

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as0 specified and directed.

71

-

-

... More
Taking out from trenches, floors, road, wall, pipe, pole LT cable of any size/description and removing and reuse from site incl making good the disturbed surfaces to match with existing surface all as directed.

1975

-

-

... More
Relaying of serviceable LT UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 95 sqmm 3.5 core complete all as specified and directed.

57

-

-

... More
All as per serial item no 6.00 above but of cross sectional area 50 sqmm, 3.5 core -ditto-

60

-

-

... More
All as per serial item no 6.00 above but of cross sectional area 16 sqmm, 4 core -ditto-

58

-

-

... More
All as per serial item no 6.00 above but of cross sectional area 25 sqmm, 4 core -ditto-

80

-

-

... More
Supply and laying of LT UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 240 sqmm 3.5 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. (Note: Excavation/earthwork, cable protection pipe, sand cushioning , brick protection and cable joint shall be measured and paid for separately

187

-

-

... More
All as per serial item no 10.00 above but of cross sectional area 150 sqmm, 3.5 core -ditto-

174

-

-

... More
All as per serial item no 10.00 above but of cross sectional area 120 sqmm, 3.5 core -ditto-

208

-

-

... More
All as per serial item no 10.00 above but of cross sectional area 95 sqmm, 3.5 core -ditto-

267

-

-

... More
All as per serial item no 10.00 above but of cross sectional area 70 sqmm, 3.5 core -ditto-

357

-

-

... More
All as per serial item no 10.00 above but of cross sectional area 50 sqmm, 3.5 core -ditto-

345

-

-

... More
All as per serial item no 10.00 above but of cross sectional area 25 sqmm, 4 core -ditto-

358

-

-

... More
All as per serial item no 10.00 above but of cross sectional area 35 sqmm, 3.5 core -ditto-

130

-

-

... More
All as per serial item no 10.00 above but of cross sectional area 16 sqmm, 4 core -ditto-

355

-

-

... More
Disconnected complete HT electric connection from existing VCBs and transformer of different type for shifting to another sub stations with suitable hydraulic machine and complete re-connection of HT cables with proper indoor Joint, lugs , complete finishing of disturbed surface/ floor area of sub stations with suitable civil works complete all as specified and directed. (Notes :- (i) HT cables , Joints shall be measured and paid for separately (ii) Disconnected Transformer will be shift to MES store yard at AGE E/M Ramgarh )

5

-

-

... More
Supply, laying in trenches, testing and commissioning XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with standard aluminium conductor, 11000 volts (earthed) grade having cross sectional area 120 sqmm 3 core complete all as specified and directed. (Note: Excavation/earthwork, cable protection pipe, sand cushing, brick protection and cable joint shall be measured and paid for separately

138

-

-

... More
Supply and fixing for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed.

6

-

-

... More
Supply and fixing for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed.

2

-

-

... More
Material and labour for cable route indicator showing "LT Cable" and route of cable with arrow made of CI in suitable eliptical/round shape and fixed on angle iron 40x40x6mm, 800mm long painted in blue colour with two coats of synthetic enamel paint cover a coat of red oxide primer duly embaded in PCC block (0.40x0.40x0.40) m including in ground and 0.15m above ground lable complete all as directed and specified.

120

-

-

... More
Material and labour for laying GI tubing light grade 50mm dia for cable potection in road/floor complete all as specified and directed.

18

-

-

... More
Material and labour for laying GI tubing light grade 100 mm dia for cable potection in road/floor complete all as specified and directed.

24

-

-

... More
Demolition of concrete (coping of PCC/GI pole/road) of any description and in any position complete all as specified and directed.

1.5

-

-

... More
Material and labour for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around exiting poles, earth pit, including provision of necessary form work, finishing even and smooth without using extra cement complete all as specified and directed.

3

-

-

... More
Material and labour for plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in road cutting filling, foundation, fencing post , struts etc. complete all as specified and directed.

4.75

-

-

... More
Supply and fixing in replacement of MCCB 630 Amp rating,4-pole 415V, breaking capacity 50 KA, adjustable & fixed magnetic setting type Ics 100% of Icu complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of MCCB 400Amp rating,4-pole 415V, breaking capacity 36 KA, adjustable and fixed magnetic setting type Ics 100% of Icu complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of MCCB 350 Amp rating,4-pole 415V, breaking capacity 36 KA, adjustable and fixed magnetic setting type Ics 100% of Icu complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of MCCB 250Amp rating,4-pole 415V, breaking capacity 36KA, adjustable and fixed magnetic setting type Ics 100% of Icu complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement of MCCB 160Amp rating,4-pole 415V, breaking capacity 36 KA, adjustable and fixed magnetic setting type Ics 75% of Icucomplete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of MCCB 250Amp rating,3-pole 415V, breaking capacity 36KA. adjustable and fixed magnetic type setting Ics 75% of Icu complete all as specified and directed.

4

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost all as directed. (Note: GI strip & GI pipe beyond 7.5Mtr length from earth electrode shall be measured and paid separately).

25

-

-

... More
Material and labour for earthing complete with copper earth plate 600x600x3mm thick electrode and 32x6 mm copper strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground connected to copper strip earth lead by means of bolts, nuts, check , nuts and washers of copper all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and directed.(Note : Copper strip & GI pipe 40mm dia beyond 7.5mtr length from earth plate shall be measured & paid separately under respective item)

7

-

-

... More
Supply and fixing 4 pole on load change over switch 400 Amp alongwith connected accessories complete all as specified and directed

2

-

-

... More
Supply and fixing 4 pole change over switch 200 Amp alongwith connected accessories complete all as specified and directed

1

-

-

... More
Supply and fixing automatic power factor contactor 75 Amp 3 pole 415 volt ,37 KW, AC3 complete all as specified and directed.

2

-

-

... More
Supply and fixing automatic power factor contactor 50 Amp 3 pole 415 volt ,25 KW,AC3 complete all as specified and directed.

3

-

-

... More
Supply and fixing automatic power factor contactor 40 Amp 3 pole 415 Volt ,22 KW,AC3 complete all as specified and directed.

5

-

-

... More
Supply and fixing automatic power factor contactor 32 Amp 3 pole 415 Volt , 15 KW,AC3 complete all as specified and directed.

4

-

-

... More
Supply and fixing contactor NO+2NC 415 Volt complete all as specified and directed.

3

-

-

... More
Supply and fixing automatic power factor controller relay 8 Steps , 230 volt complete all as specified and directed.

4

-

-

... More
Supply and fixing automatic power factor controller relay 12 steps , 230 volt complete all as specified and directed.

3

-

-

... More
Material and labour for HDPE double wall corrugated pipe of size 63mm outer dia and 50mm inner dia confirming to IS marked including necessary pipe fittings such as couplers, end caps, bend etc. including fixed to wall/roof /pole/trench as required with suitable clamps for cable protection complete all as specified and directed.

2536

-

-

... More
All as per serial item no 46.00 above but size of outer dia 90 mm dia and inner dia size 75 mm -ditto-

95

-

-

... More
Supply, installation, commissioning and testing of factory made (CPRI approved) LT Panel outdoor type of suitable size, made ot of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2 mm thick CRCA sheet for fixing of MCCB and instrumentations compartments and frame etc. to accommodate the incoming and outgoing MCCBs/ COs / motor starter duly powder coated (The inner/outdoor shell. will have powder coated siemens grey) and having provision for front and rear side opening with rubber beading and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, The panel shall be placed on angle iron of size 50 x 50 x 6 mm frame supported on 04 legs 600 mm long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 angle frame shall be provided with mild steel sheet 300 mm width and 1.6 mm thick on three sides duly fixed with nuts and bolts including taking down of old unsv LT panel complete all as specified and directed. Panel shall comprise of the following:- (a) Aluminium bus bar mounted on insulators duly painted colour code 1000 Amps - 3 nos for phase and 630 Amps - 01 no for neutral. (b) Incoming MCCB 4 pole, 630 Amps, rupturing capacity 50 KA,415 volts AC, adjustable thermal and magnetic setting-01 No. (c) ON-load changeover switch panel mounted type 400 Amps, 4 pole (d) Out going MCCB's TP 250 Amps rapturing capacity 36 KA - 01 No's (e) Out going MCCB's TP 200 Amps rapturing capacity 36 KA - 01 No's (f) Out going MCCB's TP 160 Amps rapturing capacity 36 KA - 01 No's (g) Out going MCB's TP 63 Amps - 02 No's (h) Multifunction Meter Digital type showing V,A,F,Pf Kw,KWH in built Selector switch with CT coils for three phase. (j) Indicator lamp neon type (RYB) with holder,one set for each incoming and out going - 01 Sets (k) Complete internal wiring with suitable sizes copper conductor PVC insulated all as per manufacturer design (l) Danger Notice plate 440V with conventional skull and bones in red signal colour.

1

-

-

... More
Supply, installation, commissioning and testing of factory made (CPRI approved) LT Panel outdoor type of suitable size, made ot of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2 mm thick CRCA sheet for fixing of MCCB & instrumentations compartments and frame etc. to accommodate the incoming and outgoing MCCBs/ COs / motor starter duly powder coated (The inner/outdoor shell. will have powder coated siemens grey) and having provision for front and rear side opening with rubber beading and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, The panel shall be placed on angle iron of size 50 x 50 x 6 mm frame supported on 04 legs 600 mm long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 angle frame shall be provided with mild steel sheet 300 mm width and 1.6 mm thick on three sides duly fixed with nuts and bolts including asking down of old unsv LT panel complete all as specified and directed. Panel shall comprise of the following:- (a) Aluminium bus bar mounted on insulators duly painted colour code 600 Amps - 3 nos for phase and 300 Amps - 01 No for neutral. (b) Incoming MCCB 4 pole, 400 Amps, rupturing capacity 36 KA,415 Volts AC, adjustable thermal and magnetic setting-01 No. (d) Out going MCCB's TP 250 Amps repturing capacity 36 KA - 01 No's (e) Out going MCCB's TP 160 Amps rapturing capacity 36 KA - 01 No's (f) Out going MCCB's TP 100 Amps rapturing capacity 16 KA - 02 No's (g) Multifunction Meter Digital type showing V,A,F,Pf Kw,KWH in built Selector switch with CT coils for three phase. (h) Indicator lamp neon type (RYB) with holder,one set for each incoming and out going - 01 Sets (j) Complete internal wiring with suitable sizes copper conductor PVC insulated all as per manufacturer design (k) Danger Notice plate 440V with conventional skull and bones in red signal colour.

2

-

-

... More
Supply, installation, commissioning and testing of factory made (CPRI approved) LT Panel outdoor type of size 1.0 mtr x 0.5 mtrx 0.3 mtr , made ot of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2 mm thick CRCA sheet for fixing outgoing MCCBs and having provision for front and rear side opening with rubber beading and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, The panel shall be placed on angle iron of size 50 x 50 x 6 mm frame supported on 04 legs 600 mm long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 angle frame shall be provided with mild steel sheet 300 mm width and 1.6 mm thick on three sides duly fixed with nuts and bolts complete all as specified and directed. panel shall comprise of the following:- (a) Aluminium bus bar mounted on insulators duly painted colour code 400 Amps - 3 nos for phase and 200 Amps - 01 no for neutral. (b) Incoming MCCB 4 pole, 400 Amps, rupturing capacity 50 KA,415 Volts AC, adjustable thermal and magnetic setting-01 no. (c) Digital volt and amps meter with indicator lamp neon type (RYB) with CT coils for three phase (d) Danger notice plate 440V with conventional skull and bones in red signal colour.

1

-

-

... More
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel outdoor type of size 1.0 mtr x 0.5 mtrx 0.3 mtr, made of of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2 mm thick CRCA sheet for fixing of outgoing MCCBs and having provision for front and rear side opening with rubber beading and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, the panel shall be placed on angle iron of size 50 x 50 x 6 mm frame supported on 04 legs 600 mm long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 angle frame shall be provided with mild steel sheet 300 mm width and 1.6 mm thick on three sides duly fixed with nuts and bolts complete all as specified and directed.. Panel shall comprise of the following:- (a) Aluminium bus bar mounted on insulators duly painted colour code 400 Amps - 3 nos for phase and 200 Amps - 01 no for neutral. (b) Incoming MCCB 4 pole, 350 Amps, rupturing capacity 50 KA,415 Volts AC, adjustable thermal and magnetic setting-01 No. (c) Digital volt and amps meter with indicator lamp neon type (RYB) with CT coils for three phase (d) Danger notice plate 440V with conventional skull and bones in red signal colour.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.