Maharaja Agrasen Medical College Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Maharaja Agrasen Medical College - MAMC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date7 Nov 2023
Closing Date17 Nov 2023
Tender Amount₹ 31,39,000 
Notes
Download

Costs

  • EMD

    ₹ 62,780
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level HSR:6.33 Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6.33.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

2631.04

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. HSR:6.34 Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6.34.6

5706.4

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : HSR:6.14 6.14.1 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

33.75

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : HSR:6.15 6.15.1 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)

10.98

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). HSR:6.16

43.47

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for HSR:6.30 6.30.1 Foundations, footings, bases of columns, etc. for mass concrete

106.62

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR:6.30.5

207.24

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts HSR:6.30.6

61.62

-

-

... More
Suspended floors, roofs, landings, balconies and access platform HSR:6.30.3

205.77

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: HSR:7.21 7.21.2 Cement mortar 1:6 (1 cement : 6 coarse sand)

22.45

-

-

... More
Providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR:4.39

197.38

-

-

... More
Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) HSR:6.9 6.9.2 40mm thick

20.92

-

-

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. HSR:6.10

20.92

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: HSR:13.3 13.3.2 Profile C 13.3.2.1 Fixing with adjustable lugs with split end tail to each jamb

32.2

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: HSR:13.3 13.3.3 Profile E 13.3.3.1 Fixing with adjustable lugs with split end tail to each jamb

142.41

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. HSR:13.29 13.29.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

457.56

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : HSR:7.22 7.22.2 Cement mortar 1:6 (1 cement : 6 coarse sand)

36.19

-

-

... More
Half brick masonry with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level. HSR:7.28 7.28.2 Cement mortar 1:4 (1 cement :4 coarse sand)

9.85

-

-

... More
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. HSR:9.58 9.58.1 Coupler 9.58.1.2 110mm

22.86

-

-

... More
Bend 87.5° HSR:9.58.5 9.58.5.2 110mm bend

6

-

-

... More
CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster HSR:11.4 11.4.2 1:3 (1 cement: 3 fine sand)

301.73

-

-

... More
CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : HSR:11.5 11.5.3 1:4 (1 cement: 4 fine sand)

133.84

-

-

... More
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. HSR:11.14

213.66

-

-

... More
CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR:10.1 10.1.1 Re-compacting excavated soil in plinth under floors, including watering, ramming, consolidating and dressing complete.

176.99

-

-

... More
Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : HSR:10.37 10.37.1 25mm thick

176.99

-

-

... More
Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. HSR:10.38

12.27

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. HSR:10.59

3.21

-

-

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. HSR:1058

25.23

-

-

... More
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR:11.58

649.23

-

-

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade HSR:11.64 11.64.1 New work (two or more coats) over and including water thinnable priming coat with cement primer

649.23

-

-

... More
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: HSR:9.11 9.11.1 With common burnt clay non-modular brick tile of class designation 10

197.38

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR:9.18

6

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : HSR:9.17 9.17.1 In 75x75 mm deep chase

60.82

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: HSR:12.37 12.37.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

11.34

-

-

... More
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. HSR:12.10 12.10.2 Kiln seasoned and chemically treated Hollock wood 12.10.2.2 30mm thick

4.68

-

-

... More
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : HSR:12.19 12.19.1 35 mm thick shutters 12.19.1.1 with ISI marked M.S. pressed butt hinges bright finished of required size 12.19.1.1.2 Kiln seasoned and chemically treated Hollock wood

4.68

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR:11.77

96.22

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR:11.78

96.22

-

-

... More
Providing & fixing marker board complete in all respect. Size 8'-0"x4'-0" NS

3

-

-

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : HSR:12.98 12.98.1 300x16 mm

5

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : HSR:12.99 12.99.2 250x10 mm

5

-

-

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : HSR:12.102 12.102.1 125 mm

10

-

-

... More
100 mm HSR:12.102.2

24

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : HSR:12.99 12.99.5 100x10 mm

24

-

-

... More
Providing and fixing aluminium casement stays, ISI marked, anodised transparent or dyed to required colour and shade or powder coated or polyester powder coated, with necessary screws etc. complete. HSR:12.104 12.104.2 Anodized (AC-15) Aluminium

12

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. HSR:12.103 12.103.2 Twin rubber stopper

3

-

-

... More
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay non-modular bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). HSR:7.55

51.43

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. HSR:6.13

51.43

-

-

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : HSR:12.9 12.9.7 Float glass panes 12.9.7.1 4 mm thick glass pane (weight not less than 10kg/sqm).

12.06

-

-

... More
Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. HSR:10.22 10.22.1 40 mm wide and 4 mm thick

50

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for : HSR:6.29 6.29.2 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.

102.86

-

-

... More
Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): HSR:11.25 11.25.1 Flush / Ruled/ Struck or weathered pointing

197.38

-

-

... More
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete HSR:12.48 12.48.3 25 mm dia

20.1

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : HSR:11.95 11.95.1 New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

51.43

-

-

... More
Earth filling under floor brought from out side including compaction complete in all respect as per direction of Engineer-in-charge. NS

177.64

-

-

... More
Public Health Work Items Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: HSR 22.22 22.22.1 White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

1

-

-

... More
Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : HSR 22.23 22.23.1 W.C. pan with ISI marked white solid plastic seat and lid

1

-

-

... More
Providing and fixing brass bib cock of approved quality : HSR 22.96 22.96.1 15 mm nominal bore

2

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- HSR 22.2 22.2.1 White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

2

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. HSR 22.85 Internal work - Exposed on wall 22.85.3 25 mm nominal outer dia Pipes

145

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. HSR 22.86 Concealed work, including cutting chases and making good the walls etc. 22.86.3 25 mm nominal outer dia Pipes

31

-

-

... More
Providing and fixing Unplasticised PVC connection pipe with brass unions : HSR 22.101 22.101.2 45 cm length 22.101.2.2 20 mm nominal bore

8

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. HSR 22.88 Internal work - Exposed on wall 22.88.2 20 mm dia nominal bore

5

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181

4000

-

-

... More
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. HSR 22.209

2

-

-

... More
Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge. HSR 22.216 22.216.1 25 Litres capacity

1

-

-

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR 22.38

1

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : HSR 22.103 22.103.3 25 mm nominal bore

1

-

-

... More
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109

20

-

-

... More
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. HSR 22.222 22.222.2 Single Socket Type B 22.222.2.1 160mm o/d SWR UPVC pipe lines laid complete

64

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. HSR 22.14 22.14.1.2 40 mm dia

4

-

-

... More
Providing and fixing toilet paper holder : HSR 22.42 22.42.1 C.P. brass

1

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: HSR 22.166 22.166.1 100x100 mm size P type 22.166.1.1 With common burnt clay non-modular bricks of class designation 7.5

3

-

-

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : HSR 22.92 22.92.1 25 to 40 mm nominal bore

2

-

-

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. HSR 22.107 22.107.1 15 mm nominal bore

1

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 HSR 22.108 22.108.1 15mm nominal bore

6

-

-

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : HSR 22.173 22.173.1 With common burnt clay non-modular bricks of class designation 7.5

2

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : HSR 22.174 22.174.1 With common burnt clay non-modular bricks of class designation 7.5

2

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : HSR 22.190 22.190.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 22.190.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 22.190.2.1 With common burnt clay non-modular bricks of class designation 7.5

8

-

-

... More
Extra for depth for manholes : HSR 22.191 22.191.1 Size 90x80 cm 22.191.1.1 With common burnt clay non-modular bricks of class designation 7.5

8

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: HSR 6.1 6.1.6 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

10.24

-

-

... More
Dismantling disjointing, removal and carriage to stores, G.I. pipelines, specials, valves and fittings. HSR 20.50 20.50.1 15 mm internal diametre of the pipeline

35

-

-

... More
Dismantling disjointing, removal and carriage to stores, G.I. pipelines, specials, valves and fittings. HSR 20.50 20.50.2 20 mm internal diametre of the pipeline

35

-

-

... More
20.50.3 25 mm internal diametre of the pipeline

15

-

-

... More
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : HSR 22.100 22.100.2 20 mm nominal bore

3

-

-

... More
Supply & fixing of Towel Ring round with round flange Cera, ESS, Hindware Make N.S.

2

-

-

... More
Providing & fixing P-Trap 110 x 110 mm 6 Kg cm2 with complete in all respect

10

-

-

... More
Providing & fixing C.P. lock Jali with complete in all respect N.S.

4

-

-

... More
Providing & fixing C.P. Flange with complete in all respect N.S.

20

-

-

... More
Providing & fixing 110mm x 110mm x 110mm 6 Kg cm2 door Tee with complete in all respect N.S.

4

-

-

... More
Providing & fixing 110mm 110mm x 110mm x 110mm 6 Kg cm2 door Y Tee with complete in all respect. N.S.

8

-

-

... More
Providing & fixing 110mm 6 Kg cm2 Copper / Socket with complete in all respect. N.S.

8

-

-

... More
Providing & fixing 110mm 6 Kg cm2 elbow with complete in all respect. N.S.

10

-

-

... More
Electrical Work Items Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. HSR 23.3.6 23.3.6.1 1 run of Size 1.50 Sqmm(1/1.40mm)

70

-

-

... More
23.3.6.2 1 run of Size 2.50 Sqmm(1.1.80mm)

50

-

-

... More
23.3.6.6 2 run of Size 1.50 Sqmm(1/1.40mm)

50

-

-

... More
23.3.6.7 2 run of Size 2.50 Sqmm(1.1.80mm)

50

-

-

... More
23.3.6.8 2 run of Size 4 Sqmm(1/2.24mm)

50

-

-

... More
Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. HSR 23.4.1 23.4.1.3 Group A

47

-

-

... More
Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. HSR 23.4.2 23.4.2.3 Group A

3

-

-

... More
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch HSR 23.4.3 23.4.3.3 Group A

5

-

-

... More
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required HSR 23.4.4 23.4.4.3 Group A

8

-

-

... More
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required HSR 23.4.5 23.4.5.3 Group C

12

-

-

... More
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. HSR 23.7.6 23.7.6.1 PVC pipe of 20 mm dia.

10

-

-

... More
23.7.6.2 PVC pipe of 25 mm dia.

70

-

-

... More
23.7.6.3 PVC Pipe of 32 mm dia.

70

-

-

... More
Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. HSR 23.8.2 23.8.2.2 3mm thick

500

-

-

... More
Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite 0 sheet as below HSR 23.8.3 23.8.3.1 75 mm x 75 mm x 60 mm deep M.S. box

4

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. HSR 23.8.10 23.8.10.1 1 & 2 Modules including combined plate for Telephone and data

1

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. HSR 23.8.11 23.8.11.1 5 amp 1 way switch

40

-

-

... More
23.8.11.4 5 amp Socket

20

-

-

... More
23.8.11.6 Bell Push

2

-

-

... More
23.8.11.7 step type Fan Regulator 2 modules 300 watt

20

-

-

... More
23.8.11.10 Blanking plate

20

-

-

... More
23.8.11.11 RJ 45 computer data socket outlet for CAT 6 or CAT 6e cable modular type

1

-

-

... More
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. HSR 23.22.1 23.22.1.3 Triple pole MCCB 16 to 100 amp 25KA

1

-

-

... More
Dismantling old wiring points ( surface wiring system ) including necessary repairs to wall etc. HSR 23.25.1 23.25.1.1 Light, fan or call bell Point including circuit/sub main wiring

3

-

-

... More
Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR 24.1.3

2

-

-

... More
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HSR 24.1.5

2

-

-

... More
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.HSR 24.1.7

10

-

-

... More
Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required HSR 24.1.12

40

-

-

... More
Supply, erection, testing of celling fans ISI marked ( as per IS code 374) with satabile GI pipe complete in all respectes complete as per deration of engginering incharge HSR 20.71 HSR 20.71.1 48" (1200mm)

20

-

-

... More
Supply, erection, testing of exhust fan ( as per IS code 374) having a capacity of 45 cubic meter per minute coplete with sutabile GI sheet duting in structre confirming to letest IS speciflcation complete in all respect to satisfaction of engginering incharge

2

-

-

... More
Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. HSR 24.2.6 24.2.6.1 1.5 Sqmm

25

-

-

... More
24.2.6.2 2.5 Sqmm

5

-

-

... More
24.2.6.3 4Sqmm

10

-

-

... More
S/E testing and commissioning of cubical type, dust and verman proof wall mounting LT panel made out of 20G M.S. sheet painted with strong synthetic light gray enamal paint suitable for operation on 3 phase 4 wire 50 cycles 400/440 volts A.C. supply including the cost of the following items N.S. 1 INCOMING:- Only space for accomdating 1 no. MCCB of 200amp. Three pole complete with siutable size of cable chamber to receive incoming cable in sheet steel cubical. Neutral Link A set of LED lamps (3 nos.) phase indicating light OUTGOING: L.T.Penal should be having sufficeint spce for accomodating the following switches/ M.S.B.'s including the cost of the MCCB,MCB and metering system as required. 2Nos 32Amp four pole 10KA MCCB and 14 Nos single pole MCB all itmes cost include The panel should be completed with all inter wiring with PVC copper wire and testing etc. complete the job in all respect upto the entire satisfaction of Engineer In-charge of the work

1

-

-

... More
S/E/I/T/C of out door light fixture including the cost of 15 watt LED blub and outer iron frame complete with all fixing acceseries as reqiored upto the entire satisfaction of the Engineer In-charge of the work. Make - Bajaj/Philips/Havells (NS )

12

-

-

... More
Supply and erection of underground cable loose in existing pipe or trenches complete with necessary connections 10 sqmm 4 core cable Armoured (NS-)

150

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.