If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 58,50,000Document Cost
₹ 11,800Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_HBC_165994_1Bid Award Id
ViewTender No
NIT NO 19/ PDCTender Authority
Haryana Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://www.hvpn.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
ii) +6m extn. Only
2
-
-
132kV D/C “DB” KRR Design type Tower
48
-
-
i) +3m extn. Only
18
-
-
ii) +6m extn. Only
10
-
-
iii) +9m extn. Only
5
-
-
132kV D/C “DC” KRR Design type Tower
18
-
-
i) +3m extn. Only
10
-
-
ii) +6m extn. Only
1
-
-
iii) +9m extn. Only
2
-
-
132kV D/C “DD” KRR Design type Tower
28
-
-
i) +3m extn. Only
4
-
-
ii) +6m extn. Only
1
-
-
iii) +9m extn. Only
3
-
-
iv) +18m extn. Only
4
-
-
v) Extra cross arm(Set of 3)
1
-
-
132KV D/C Gantry(KRR Design)
8
-
-
Design, testing, Fabrication, Supply, Erection & Commissioning of 132kV D/C Monopole with Foundation (Raft/Pier/Pile) & all parts like cross arms, bolts & nuts, step bolts, U-bolts, D-shackle etc. with maximum. span length of 300 mtr.
Detail of monopole with Deviation angle space for foundation above & below ground/height of Bottom cross-arm
132kV D/C “PA” Monopole (00 - 20) 4mtr/14.21mtr
4
-
-
132kV D/C “PB” Monopole (00 - 150) 4mtr/14.21mtr
1
-
-
132kV D/C “PC” Monopole (150 - 300) 4mtr/14.21mtr
1
-
-
132kV D/C “PD” Monopole (00 - 900) 4mtr/14.21mtr with extra cross arm(Set of 3)
2
-
-
Supply of earthing of towers
i) Pipe type
167
-
-
Supply of following Tower accessories
i) Danger Plate
167
-
-
ii) Number Plate
167
-
-
iii) Phase Plate(set of 3)
235
-
-
iv) Circuit Plate (set of 2)
296
-
-
v) Bird Guard (Set of 3)
172
-
-
vi) Anti climbing device
167
-
-
LINE MATERIAL
Conductor (ACSR Zebra)
300
-
-
Earth Wire (7/3.15mm)
14.45
-
-
132KV Anti-Fog type Disc Insulator or Silicon Rubber Polymer Insulator strings* i) 70 kN
534
-
-
ii) 120 kN
1500
-
-
132kV Post Insulators
60
-
-
Hardware Fittings i. Single ‘I’ Suspension String
516
-
-
ii. Single suspension pilot string
27
-
-
iii. Single Tension string
1386
-
-
iv. Double tension string
48
-
-
Conductor & Earth wire Accessories
i) Mid Span Compression Joint for ACSR Zebra Conductor
200
-
-
ii) Mid Span Compression Joint for earth wire
11
-
-
iii) Repair sleeves for ACSR Zebra Conductor
60
-
-
iv) Flexible copper Bond
65
-
-
v) Vibration damper for ACSR Zebra Conductor
3900
-
-
vi) Vibration damper for earthwire
192
-
-
vii) Earth-wire Tension clamp
73
-
-
viii) Earth-wire suspension clamp
24
-
-
ix) Repair Sleeve for earthwire
3
-
-
OPGW/UGFO and wideband communication equipments
OPGW (24 fiber) (DWSM, G.652D) (equivalent to Earth wire 7/3.15mm in all respect)
29
-
-
Hardware set for above 24 Fibre UGFO Fibre Optic cabling including all cable fittings and accessories except Joint Box.
29
-
-
FODP 48F: Indoor type, rack mounted with FCPC coupling and pig tails (5mtrs. Each) as applicable at 220kV S/Stn. DeroliAhir&132kV S/Stn. IMLH, Nangal Choudhary
2
-
-
Joint Box 24F fiber OPGW to OPGW (as applicable)
10
-
-
Joint Box 24F fiber OPGW to FOAC (as applicable)
2
-
-
Fiber optic Approach cable, 24 fiber (DWSM) along with PLB HDPE Ducts of suitable size & strength and all accessories (220kV S/Stn. DeroliAhir& 132kV S/Stn. IMLH, Nangal Choudhary)
2
-
-
Wideband Communication Equipment and spares
Telecom equipment at 132kV S/Stn. IMLH Nangal Choudhary
SDH Equipment (STM - 16 MADM upto 5 MSP protected directions)
Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding (22.1) to (23.3 ) below
1
-
-
Optical Interface Cards/SFP
S16.1 SFP (the quantities will be decided at the time of detail engineering)
4
-
-
L16.2 SFP (the quantities will be decided at the time of detail engineering)
4
-
-
S4.1 SFP (the quantities will be decided at the time of detail engineering)
4
-
-
L4.2 SFP (the quantities will be decided at the time of detail engineering)
4
-
-
Tributary cards
E1 Interface card (Min. 32 interfaces per card)
2
-
-
Ethernet Interface 10/100 BaseT with Layer-2 switching (min8 interfaces per card)
2
-
-
Gigabit Ethernet (Layer 2) Interface (min 2 nos)
1
-
-
Equipment Cabinet with DDF and all installation accessories
1
-
-
Network Manager System - Craft Terminal
Hardware
1
-
-
Software
1
-
-
VOIP telephone instrument with one common switch (min. 8 port) compatible with SLDC
1
-
-
Integration of the Equipment with existing network
1
-
-
Mandatory spares
Telecom equipment at 220KV S/Stn. DeroliAhir and 132kV S/Stn. IMLH Nangal Choudhary)
SDH Equipment (STM - 16 MADM upto 5 MSP protected directions)
Optical Interface Cards/SFP
S16.1 SFP (the quantities will be decided at the time of detail engineering)
2
-
-
L16.2 SFP (the quantities will be decided at the time of detail engineering)
2
-
-
S4.1 SFP (the quantities will be decided at the time of detail engineering)
2
-
-
L4.2 SFP (the quantities will be decided at the time of detail engineering)
2
-
-
Tributary cards
E1 Interface card (Min.32 interfaces per card)
1
-
-
Ethernet Interface 10/100 Base T with Layer-2 switching (min 8 interfaces per card)
1
-
-
Gigabit Ethernet (Layer 2) Interface (min 2 nos.)
1
-
-
Pre Connectorized OpticalFibre Patch Cords (10 Mtrs.)-Pack of six Patch cords
1
-
-
Detailed Survey
41.16
-
-
Furnishing bore log data
44
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 132kV D/C 'DA' type Tower (KRR Design) classified as - Dry
55
-
-
- Wet (w/out de-watering)
2
-
-
ii) 132kV D/C 'DB' type Tower (KRR Design) classified as - Dry
40
-
-
- Wet (w/out de-watering)
3
-
-
iii) 132kV D/C 'DC' type Tower (KRR Design) classified as - Dry
15
-
-
- Wet (w/out de-watering)
1
-
-
iv) 132kV D/C 'DD' type Tower (KRR Design) classified as - Dry
20
-
-
- Wet (w/out de-watering)
1
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 9 to 25Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
i) 132kV D/C 'DB+9m extn.' type Tower (KRR Design) classified as - Dry
5
-
-
ii) 132kV D/C 'DC+9m extn.' type Tower (KRR Design) classified as - Dry
2
-
-
iii) 132kV D/C 'DD+9,+18m extn.' type Tower (KRR Design) classified as - Dry
7
-
-
Construction of 132kV D/C gantry foundation as per KRR Design one set consist of T-1 & T-2 (3 no. footings in one set ) including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
8
-
-
Dewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for foundations/stub and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements and irrespective of type of tower including extensions if any i.e. KRR design or TATA design.
2
-
-
Protection Measure
Brick masonry in 1:4 cement sand mortar including excavation
4
-
-
Earth filling, compaction, leveling etc inside revetments
4
-
-
M-20 (1:1½ :3 mix) concrete for top seal cover, for revetment etc.
2
-
-
Lean concrete (1:4:8)
2
-
-
RCC 1:1.5:3 (M20) including all material, labour, excavation, cutting and placing of steel, centering & shuttering, concreting etc. complete in all respect.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements