Haryana Tourism Corporation Limited Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Haryana Tourism Corporation Limited Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Feb 2024
Closing DateCancelled
Tender Amount₹ 5,51,46,000
Costs
EMD
₹ 11,03,000Document Cost
₹ 23,600Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HBC_354946_1Bid Award Id
ViewTender No
202419EF981A DDFA 4B03 B96F F322E1E33FA91270HTCTender Authority
Haryana Tourism Corporation Limited ViewPurchaser Address
-Website
http://etenders.hry.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
UPS Panel (UPS feeder Panel) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid.
INCOMER : 800 AMP TP+NL ACB x 1 No., 630 AMP TP+NL MCCB x 1 No.,
BUS BAR : 800 AMP, 500 Volts, 3 phase 50 HZ TP+2N high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUTGOING : 400 AMP 4P MCCB 15kA 5 Nos. WITH INDICATION LAMPS All Items complete as above
1
-
848357
A-MDB-LG ( RAW Panel Block-A ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 250 AMP 15kA TP+NL MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 250 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 63 AMP 4P 15kA MCCB 1 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
40 AMP 4P 15kA MCCB 13 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
16 AMP DP MCB 15kA 2 Nos.
complete panel as above and complete
1
-
366646
B-UMDB-BL as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid.
INCOMER : 400 AMP TP+NL 15kA MCCB X 4 Nos. BUS BAR : 1500 AMP, 500 Volts, 3 phase 50 HZ TP+2N high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUTGOING : 400 AMP 4P 15kA MCCB x 1 No. WITH INDICATION LAMPS 250 AMP 4P 15kA MCCB x 2 Nos. WITH INDICATION LAMPS 200 AMP 4P 20kA MCCB x 1 No. WITH INDICATION LAMPS 160 AMP 4P 20kA MCCB x 1 No. WITH INDICATION LAMPS 100 AMP 4P 20kA MCCB x 3 Nos. WITH INDICATION LAMPS All Items complete as above
1
-
670529
A-USMDB-LG ( UPS Panel Block-A ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 400 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 400 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 100 AMP 4P 15kA MCCB 1 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
63 AMP 4P 15kA MCCB 12 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
40 AMP 4P 15kA MCCB 1 No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
370883
B-USMDB-BL ( UPS Panel Block-B ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 250 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 250 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 80 AMP 4P 15kA MCCB 1 No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
63 AMP 4P 15kA MCCB 7 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
193717
C-USMDB-BL ( UPS Panel Block-C ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 250 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 250 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 63 AMP 4P 15kA MCCB 6 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
80 AMP 4P 15kA MCCB 2 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
193717
D-USMDB-GF ( UPS Panel Block-D ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 200 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 200 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 63 AMP 4P 15kA MCCB 7 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
178887
E-USMDB-GF ( UPS Panel Block-E ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 160 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 160 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 63 AMP 4P 15kA MCCB 5 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
145387
G-USMDB-GF ( UPS Panel Block-G ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 100 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 100 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 63 AMP 4P 15kA MCCB 6 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
148433
A-ESMDB-GF ( Emergency Panel Block-A)
as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 80 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 80 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 40 AMP 4P 15kA MCCB 5 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
20 AMP 4P 15kA MCCB 1 No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
148433
B-ESMDB-BL ( Emergency Panel Block-B)
as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 100 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 100 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 40 AMP 4P 15kA MCCB 6 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
20 AMP 4P 15kA MCCB 2 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
178622
C-ESMDB-BL ( Emergency Panel Block-C)
as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 250 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 250 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 160 AMP 4P 15kA MCCB 1 No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
63 AMP 4P 15kA MCCB 4 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
40 AMP 4P 15kA MCCB 2 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
32 AMP 4P 15kA MCCB 3 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
20 AMP 4P 15kA MCCB 1 No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
272502
D-ESMDB-GF ( Emergency Panel Block-D)
as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 100 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 100 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 40 AMP 4P 15kA MCCB 6 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
155318
B-MDB-LG ( RAW Panel Block-B ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 250 AMP 15kA TP+NL MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 250 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 63 AMP 4P 15kA MCCB 2 No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
40 AMP 4P 15kA MCCB 12 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
310371
C-MDB-LG ( RAW Panel Block-C ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 160 AMP 15kA TP+NL MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 160 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 40 AMP 4P 15kA MCCB 14 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
32 AMP 4P 15kA MCCB 2 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
350624
D-MDB-GF ( RAW Panel Block-D ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 160 AMP 15kA TP+NL MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 160 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 80 AMP 4P 15kA MCCB 1 No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
40 AMP 4P 15kA MCCB 9 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
249595
E-MDB-GF ( RAW Panel Block-E ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 100 AMP 15kA TP+NL MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 100 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 40 AMP 4P 15kA MCCB 6No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
32 AMP 4P 15kA MCCB 4Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
233970
G-MDB-GF ( RAW Panel Block-G ) as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 400 AMP 15kA TP+NL MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 400 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 40 AMP 4P 15kA MCCB 10 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
32 AMP 4P 15kA MCCB 4 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
63 AMP 4P 15kA MCCB 4 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
419081
E-ESMDB-GF ( Emergency Panel Block-E)
as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 100 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 100 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 40 AMP 4P 15kA MCCB 6 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
146314
G-ESMDB-GF ( Emergency Panel Block-G)
as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 100 AMP TP+NL 15kA MCCB with Thermal Magnetic protection, Indication lamps BUS BAR : 100 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 40 AMP 4P 15kA MCCB 7 Nos. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
32 AMP 4P 15kA MCCB 1 No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
20 AMP 4P 15kA MCCB 1 No. WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS
complete panel as above and complete
1
-
203118
P-PVDB ( Solar Feeder Panel Parking)
as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 250 AMP FP 20kA MCCB 2 Nos. with Thermal Magnetic protection, Indication lamps 200 AMP FP 20kA MCCB 1 No. with Thermal Magnetic protection, Indication lamps 100 AMP FP 20kA MCCB 1 No. with Thermal Magnetic protection, Indication lamps BUS BAR : 1000 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 800 AMP 4P 20kA MCCB WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS complete panel as above and complete
1
-
348109
B-PVDB-BL ( Solar Feeder Panel Blook- B)
as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 200 AMP FP 20kA MCCB 1 No. with Thermal Magnetic protection, Indication lamps 125 AMP FP 20kA MCCB 2 Nos. with Thermal Magnetic protection, Indication lamps 80 AMP FP 20kA MCCB 1 No. with Thermal Magnetic protection, Indication lamps BUS BAR : 630 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 400 AMP 4P 20kA MCCB WITH THERMAL MAGNETIC PROTECTION AND INDICATION LAMPS complete panel as above and complete
1
-
231454
SS-PVMDB ( Solar Feeder Panel Substation )
as per technical specifications below : Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchboard suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing, SPD Provision which connected to the nearest earth grid.
INCOMER : 800 AMP FP 15kA MCCB 2 Nos. with Thermal Magnetic protection, Indication lamps 400 AMP FP 15kA MCCB 2 Nos. with Thermal Magnetic protection, Indication lamps
160 AMP FP 15kA MCCB 1 No. with Thermal Magnetic protection, Indication lamps
BUS BAR : 2000 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.6 sq. mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.
OUT GOINGS : 1800 AMP 4P 50kA ACB with INDICATION LAMPS complete panel as above and complete
1
-
1080341
HT Panel 630A for main supply from HT meter cubical
1
-
576833
PART- B : AHU, Insulation
Supply, installation, testing and commissioning of Verticle/Horizontal Floor Mounted/Ceiling suspended Airhandling units having following specifications:
Frame Structure shall consist of 48mm Extruded Aluminium thermal break profile.
Panel: 46mm thick double skin sandwich panels with PUF insulation of density 40 kg/cum. The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.6 mm thickness for the inner skin of GI and it consist of following sections with Mixing Box
Filtration Section shall be provided with first stage pre-filter (MERV 8) of 90% efficiency down to 10 micron and secondary stage ESP filter (MERV-14) of 99% efficency down to 3 micron. Megnehelic gauge to be provided for pre and ESP filters.
Coil Section: Chilled water coil multi row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. All air handling units to be provided with minimum 6 row deep LT Coil & 6 Row deep HT Coil . All TFA/AHU shall be accompany with two set of cooling coil (Primary cooling coil & secondary de-humidification coil). Following size:--
The coil face velocity shall not exceed 2.5m/sec. Drain Pan: Condensate drain pan shall be fabricated from 18 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation.
Each Air Handling Units, shall be complete with direct driven Plug Fan airfoil design blades suitable for static pressure as detailed below, Squirrel cage induction motor , cooling coils (Copper tubes and Aluminium fins), pre-filter, ESp filter, drain pan, Volume control dampers at outlets (GSS Construction) fireproof double canvass connection, mixing box, flange joint, and other accessories as per specifications (except water shut off valves, drain piping and pressure gauges which are covered under separate item).Motor shall be suitable for 415 ± 10% volts, 50 cycle, 3 Phase AC supply as indicated below
-
-
-
7000 FM 6 Row Deep (8TR LT/11.5TR HT) , 65mm S.P., 5.5 KW
2
-
832465.7
3000 CS (1LT/4.5HT) 6 Row Deep , 50mm S.P., 2.2 KW
1
-
400466
1200 CS (1LT/2HT) 6 Row Deep , 50mm S.P., 1.1 KW
1
-
293755
1200 CS (0.5LT/2HT) 6 Row Deep , 50mm S.P., 1.1 KW
1
-
293755
7500 FM (8.5LT/12.5HT) 6 Row Deep , 65mm S.P., 5.5 KW
2
-
845295
12000 FM (7.5LT/20.5HT) 6 Row Deep , 65mm S.P., 7.5 KW
2
-
1216265.6
8000 FM (7.5LT/13.5HT) 6 Row Deep , 65mm S.P., 5.5 KW
2
-
887979.4
6000 CS 6 Row Deep (3.5LT/9.5HT) , 50mm S.P., 5.5 KW
1
-
689784.7
4500 CS 6 Row Deep (2.5LT/7.5HT) , 50mm S.P., 3.7 KW
1
-
611370.1
9000 FM (9LT/15HT) 6 Row Deep , 65mm S.P., 7.5 KW
2
-
990014.3
11500 FM (7LT/18HT) 6 Row Deep , 65mm S.P., 7.5 KW
2
-
1178976.7
3000 CS (6LT/4HT) 6 Row Deep , 50mm S.P., 2.2 KW
1
-
400466
1500 CS (1LT/2.5HT) 6 Row Deep , 50mm S.P., 1.5 KW
1
-
308502.7
1500 CS (2LT/0HT) 6 Row Deep , 50mm S.P., 1.5 KW
1
-
308502.7
2000 CS (1LT/3.5HT) 6 Row Deep , 50mm S.P., 1.5 KW
1
-
324449.4
Supply, installation testing & commissioning of 1.5 TR 5-star inverter split AC (Copper piping, dual filterration with HD and PM 2.5 auto cleanser) Carrier, Daiken or equivalent with stand etc as required at site.
16
-
61803
Supply, installation, testing & commissioning of suitable size copper pipe and power/communication cable for 1.5TR split AC from outdoor unit to indoor unit complete as required.
200
-
1831.2
Providing and fixing 50 mm thick FR Expanded polystyrene rigid insulation board of required size under deck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions ≤ 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
5500
-
715.88
PART- C : CABLES
Supply of following 1.1 KV grade Multicore aluminium conductor XLPE FRLS power cable insulated armored cable conforming to IS:7098 Part-1 complete with all amendment ete and should be NABL certified
-
-
-
400 sqmm 4 core AL XLPE armored
2150
-
1686
400 sqmm 3.5 core AL XLPE armored
3550
-
1418
300 sqmm 3.5 core AL XLPE armored
250
-
1116
120 sqmm 4 core AL XLPE armored
165
-
539
95 sqmm 4 core AL XLPE armored
50
-
435
Supply of following size of 11 KV grade Multicore aluminium conductor XLPE FRLS power HT cable insulated armored cable conforming to IS:7098 Part-1 complete with all amendment ete and should be NABL certified 300 SQMM 3 Core armored
300
-
1547
PART- D : UPS
Suppply installation testing and commissioning of Uniline Make 100 KVA Online UPS with Inbuilt Isolation Transformer operating in parallel redundancy
Model – Tripower TP 100
3 phase input – 3 phase output
•MS rack, Interlinks, UPS to battery Cable, Battery Isolator
•Modbus card
•Parallel Kit
4
-
1015808
12v 100 AH x 44 Nos VRLA SMF Batteries to provide 15 mins backup Make – HBL/ Leoch / U Plus
4
-
384780