Government Of Haryana Tender
... More
The Government Of Haryana has issued a formal invitation for competitive bids for Providing Drinking Water Supply Facility Of 6 No. Water Works 1 No. Tubewell Based Scheme Under Covered 10 No. Villages Raichandwala Dhillowal Naguran Kheri Naguran Hasanpur Badhana Gohian Mandi Khurd Baniya Khera Retauli Lifiting Raw Water Hansi Br in Jind, Haryana, with an estimated contract value of Rs. 39,72,000. The bid opening date for this tender is 13-08-2019 and the last date for bid submission is 21-08-2019. Interested bidders for Government Of Haryana tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 79,440Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_HRY_93773_1Bid Award Id
ViewTender No
HO/51410/15052019/RecallTender Authority
Government Of Haryana ViewPurchaser Address
-Website
http://https://haryana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
B) CI D/F pipes 150 mm i/d
50
-
-
... More
Part - II Supply and erection of Horizontal spindle spilit casing type pumping sets of minimum Four ) star rating duties directly coupled to Ac squirrel cage induction type motor with 1440 RPM, 3 phase, 50 Hz and accessories as described in Schedule No. II complete in all respect with priming arrangement with complete base frame. ii) Raw Water Pump at (P/Stn. at exst. W/W vill. Jamni)
1900 LPM, 20 Mtrs. Head
2
-
-
... More
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 500X1200mm and 400mm deep having following accessories:-
1. Incomer switch 200 Amp.
2. Aluminum bus bar chamber of 300 Amp. Capacity.
3. Volt meter 100X100mm range 0 to 500 V (AE/KAPPA/L & T 4. Indicating lamp-one set. B) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200X900mm having following accessories:-
A) Raw water pump sets for 1900 LPM x 20 M head = 2 Nos. (P/Stn. at exst. W/W vill. Jamni)
(a) Main switch 63 Amp. 2 Nos.. (L & T Siemens, ABB).
(b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T)
(d) CT 100/3 Nos. (AE/KAPPA/ L&T)
(e) VSS & ASS 1 No. each of approved make (f) SPP 1 No. of approved make
(g) Motor starter, star delta 2 Nos. for 1900 LPM x 20 M Head Motor (L&T Simens, AAB)
(h) Capacity KVAR as per site requirement (i) Indicating Lamp-One Set
( j) Change over switch 63 Amp. = 1 No.
1
-
-
... More
C) Bell Mouth 150 mm i/d
2
-
-
... More
Providing and fixing cast iron Kinetic air valves of size given below marked with IS : 14845 of Kirloskar including carriage, loading, unloading, stacking ,handling, re-handling etc. drilling, tapping, screwing in valves connections complete in all respect to the satisfaction of Engineer-in-Charge. 80mm i/d
7
-
-
... More
Supplying fixing,jointing,testing,commissioning of DI Sluice Valve resilient Sheet P.N.1.6 as per NIT specifications on the pumping machinery and rising mains including cost of jointing material.(IVC,VAG, Kirloskar make) 300mm i/d
2
-
-
... More
Supply, erection, testing and commissioning of 30 KVA/ 24 KW diesel generating set, noise control acoustic enclosure radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-) volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine. The rating should be at 1500 RPM (a) Diesel Engine (b) Alternator (c) Base Plate (d) Battery 24 V (e) 1x120 sq.mm 3.0 core XLPE Aluminum= 20 mtrs. (f ) Tools AMF Panel (a) Motorized change over switch 250 Amp. 4 P with fuse base and HRC links 250 Amp.(b) Under voltage/over voltage relay= 2 No. 415 VAC (c) Engine start relay 24 VDC 1 No. (d) Electronic Timer 24 VDC 1 No. (e) Electronic Timer 24 VAC 2 No. (f) Auxiliary relay 220 VAC 2 No. (h) Metering set 415 VAC, 1 set (Amp. Meter, volt meter, ASS, VSS, Phase indicators, control fuse, frequency meter, CT’s). (i) Metering set 24 VDC (Amp. Meter, volt meter). (j) Over load protection for DC 1 No. (k) Battery charger 24 VDC (Blueron Make) (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch (on/off) (o) Engine protection unit with audio visual alarm and shut down for low lubricating oil pressure and high coolant temperature. (p) Indicating lamp for low lubricating oil pressure high coolant temperature, set running, load on, DC control on. Note: Control panel shall have the provision to provide auto manual failure panel (AMFP
1
-
-
... More
Part- III Operation and Maintenance of MPS (Dhatrath Jamni) as per schedule-IV for a period of 5 year (60 months) after three months of trial run period. (As per scope of work taken in DNIT). Operation and maintenance during defect liability period. (Operation Only)
1
-
-
... More
4th year after defect liability period. (Operation & Maintenance)
1
-
-
... More
Supply and Fixing following CI D/F pipe and specials/Bell Mouth including cost of joining materials, laying, jointing, refilling inckuding making adequate support of masonry/ concrete for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the Department as per plan shown from the foundation wall of pump chamber for all the raw water and clear water puping sets at water works in position, as per specification given in schedule No. II. For Pumping Machinery
Detail of pipe and specials
A) CI D/F bends, Reducers, tees, tapers, tail piece, blank flange etc.pipes excluding jointing material
500
-
-
... More
Supply, erection, testing of reputed make CFL vapour light 100 watts with fitting and accessories complete in respects.
2
-
-
... More
Supplying, erection and commissioning of 3 HP electric driven dewatering pumping set capacity 5m3 per hour 15 meter total head with wiring starter, switches and G.I. Pipes and special canvas hose and accessories as per specification in schedule no. II etc. complete in all respects.
1
-
-
... More
Supplying fixing,jointing,testing,commissioning of Scoure Valve resilient Sheet P.N.1.6 as per NIT specifications on the pumping machinery and rising mains including cost of jointing material.(IVC,VAG make) 300mm i/d
1
-
-
... More
Part - I Supply, erection, testing and commissioning of 200 KVA/ 80 KW diesel generating set, noise control acoustic enclosure radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-) volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine. The rating should be at 1500 RPM (a) Diesel Engine (b) Alternator (c) Base Plate (d) Battery 24 V (e) 1x120 sq.mm 3.0 core XLPE Aluminum= 20 mtrs. (f ) Tools AMF Panel (a) Motorized change over switch 250 Amp.4 P with fuse base and HRC links 250 Amp. (b) Under voltage/over voltage relay= 2 No. 415 VAC (c) Engine start relay 24 VDC 1 No.(d) Electronic Timer 24 VDC 1 No. (e) Electronic Timer 24 VAC 2 No. (f) Auxiliary relay 220 VAC 2 No. (g) Auxiliary relay 220 VAC 3 No.(h) Metering set 415 VAC, 1 set (Amp. Meter, volt meter, ASS, VSS, Phase indicators, control fuse, frequency meter, CT’s).(i) Metering set 24 VDC (Amp. Meter, volt meter).(j) Over load protection for DC 1 No. (k) Battery charger 24 VDC (Blueron Make) (k) Battery charger 24 VDC (Blueron Make) (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch (on/off) (o) Engine protection unit with audio visual alarm and shut down for low lubricating oil pressure and high coolant temperature. (p) Indicating lamp for low lubricating oil pressure high coolant temperature, set running, load on, DC control on. Note: Control panel shall have the provision to provide auto manual failure panel (AMFP
1
-
-
... More
Supplying fixing,jointing,testing,commissioning of DI Swing Check type reflux(Non Return) valve P.N.1.6 as per NIT specifications on the pumping machinery and including cost of jointing material.(IVC,VAG make) 150 mm i/d
2
-
-
... More
Cutting DI pipes and specials and chipping or filing the surface to a uniform finish. 300mm i/d (K-9)
14
-
-
... More
Supply, erection, testing of light fittings including wire in the Pump Chamber with material up to 10 points including switch, button, plug, PVC conduct pipe and Copper wire etc. as per approved specifications complete in respects.
1
-
-
... More
Providing and fixing ceiling fan 1400 mm (56") with speed adjuster of reputed make (make Crompton, Usha, Bajaj, Orient) complete in respect..
1
-
-
... More
Providing and fixing exhaust fans 18" i/d (450mm) complete with suitable GI sheet of approved make complete in respects.
1
-
-
... More
Prov & fixing of various sizes DI specials as per ISI specification suitable for DI pipes.
200
-
-
... More
Stringing out DI (K-9) Pipes and specials castings along trenches and laying the same in ternches to correct, alignment and gradients including cartage from Divisional stores or nearest railway station to site of works and return of pieces to pipes to stores :- 300mm i/d (K-9)
700
-
-
... More
Jointing DI socketted pipes, valves and specials with rubber tyton joints fitted complete including cost of labour and tools etc. and tested complete. 300mm i/d (K-9)
127
-
-
... More
2nd year after defect liability period. (Operation & Maintenance)
1
-
-
... More
Providing & Fixing Flow Meter at Raw Water MPS near Hansi Branch & Various Water Works including specials and all types of jointing materials as per approved DNIT complete in all respect.
1
-
-
... More
1st year after defect liability period. (Operation & Maintenance)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements