Command Area Development Authority Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 7,30,500Document Cost
₹ 15,000Tender Fee
₹ 1,180
Summary
Solar Powered Based Micro Irrigation Project By Constructing Rain Water Storage Pucca Tank And Percolation Tank Earthen In Village Gothra Mohabtabad Jharna Mandir Block And District Faridabad Under Atal Bhujal Yojna
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HBC_407411_1Bid Award Id
ViewTender No
202485F7577A 01BF 4B7B 9836 3A072076014B1959CADTender Authority
Command Area Development Authority ViewPurchaser Address
-Website
http://etenders.hry.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Pro. and Fix. Tank Type (Make of Metal) Fertilizer and Chemical injector System confirming to IS 14483 (Part 3) of 2018 for demonstration and guiding the farmers regarding fertilization and Chemicalisation of System (rates including ventury with manifold 1.0” = 1300 and 60 liter fertilizer tank=4400) rate approved by Worthy Administrator MICADA, Haryana.
2
-
-
Providing fixing of Header Assembly/Manifold 3` to connenct the filtration unit (loose) (Rate app. By worthy Administrator)
2
-
-
providing and fixing of 3` plastic hydraulic control valve threaded (quick pressure relief)
2
-
-
Providing, fixing, testing and commissioning of pressure gauge 2” dial with Glycerin (NS item)
12
-
-
providing and fixing of 1.5 inch plastic air cum vacuum relief valve.
24
-
-
Providing, lowering, laying, aligning, fixing in position and jointing (with medium bodied cement solvent) at all level/ depths of TypeB, Class-2 (4 Kg/cm2)UPVC pipes for water supplies as per IS code 4985 : 2021 (amended up to date) in trenches in complete including cost of Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per directionof Engineer. Rate includes cost of all specials like bends , tees required during laying of pipe line along required alignment. UPvc Pipe 140 mm dia.
5457
-
-
providing and fixing of 2` continuous acting air cum vacuum relief vavle.
4
-
-
`Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength. Including lightning and surge voltage protection, Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to moniter plant performence (Amp-meter, Volt-meter, Frequency meter, Energy meter, Watt-meter, and other instrument/equipment as required) Note:- PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction and Part 2 – requirements for testing, for safety qualification or quivalent IS and be mounted on fixed Aluminium/GI structure of adequate strength and design as per IEC/IS specification. Including field-based electroluminescence (EL) study be performed after receiving the modules at site and after installation. Module mounting structure (MMS) design and drawing shall be duly vetted from government institute Including third party inspection Actual parameters/capacity will be finalized after approval of design and drawing. (N.S. Item)`non schedule
33
-
-
Supplying, erection, testing and commissioning of Variable Frequency Drive (VFD) complete with all accessories for the required power capacity of Solar Pump, VFD Drive for Pump set of power capacity 15 HP.
2
-
-
Hydrant assembly for Nakka in fields, Rates are including rates of Tee, riser pipe, butterfly valve, Flange and
labour for fixing butter fly valve should be as per IS 13095-2020
30
-
-
Supplying, assembling, lowering and fixing in vertical position 70% of total depth UPVC medium well casing (CM) pipe of 200 dia in bore well, with 30% of depth UPVC medium well screen (RMS) pipes with ribs conforming to IS: 12818] covered with ISI marked welded stainless Description 200 mm dia bore well steel screen (SS 304) cage Type V-Wire Wound creens, in bore wells conforming to IS:8110 and compositions of material as per IS:1012 after boring/drilling bore well of 300 mm diameter by suitable method prescribed in IS: 2800 (part 1). including collecting samples from different strata, after lowering of casing pipe bore should be packed with graded gravel in bore well of size as per IS 4097, casing pipe should be connected with horizontal- perforat pipe burried in bottom filter media (HSR Item no. 3.8.3,33.9.3,33.6.1.1,20.99)
80
-
-
NS Item -Preparation and implementation of warabandi of the complete chak and Identification of training needs of the farmers, preparation of training modules on various subjects concerning operation and maintenance of the MI systems, Solar array and pumping systems and cropping pattern etc., and providing necessary training to the farmers as per the identified needs including operation maintenance , watch andward up to 04 years. Necessary training shall be provided to the WUA members and the staff identified by the Engineer also for all activities involved in the O and M Note :- The work will be considered completed after successful completion of entire project exclusive of training and OandM of work. 10% security will be deducted in each bill of the work, which will be released after completion of work on the production of Bank Guarantee of same value , out of which 2% will be released annually after successful running and annual maintenance of the system, on the production of satisfaction certificate by concerned Executive Engineer.
1
-
-
Construction of control room/regulation cum watch and ward hut as per approved design and drawing including water supply Sanitary fittings, electric fittings, septic tank and other items as required etc ( Roof covered area 20’x20.75’) as
per approved design and drawing.
415
-
-