Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 42,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_664914_2Bid Award Id
ViewTender No
8050Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
(b) depth of manholes exc 1.50 mtr and n.exc 3.00 mtr .
250
-
-
(c) depth of manholes exc 3.00 mtr and n.exc 4.50 mtr
150
-
-
Cleaning of Chocked Sewage lines manually or mechanically necessary tools/auger/jetting machine etc as essential and taking out accumulated sludge and all foreign material from adjoining manhole complete including pumping/ removal of floating materials as required and work in foul places etc.The rates are deemed to be included for neccessary safety equipments, tools and plants, and removing the same to a distance outside of MOD land and depositing at a approved yard fixed by Defence/Local state authority with closed sewage containers complete all as specified.
-
-
-
(a) 100 mm bore SGSW/RCC drain pipe
350
-
-
(b) 150mm bore of pipe SGSW/RCC drain pipe
1500
-
-
(c) 200/300 mm bore of pipe SGSW/RCC drain pipe
1500
-
-
(c) 450 mm bore of pipe SGSW/RCC drain pipe
800
-
-
Cleaning of PVC/CI sewer/sludge pipe from floor trap,PVC bend to gully trap/manholes in ground floor.
350
-
-
Cleaning of PVC/CI sewer/sludge pipe from floor trap,PVC bend to gully trap/manholes of first floor.
200
-
-
Cleaning of PVC/CI sewer/sludge pipe from floor trap,PVC bend to gully trap/manholes of second floor.
60
-
-
Clearing blockage of WC and cleaning of Blockage in sewage line upto 1 st Manhole to the entire satisfaction of the Engineer in charge all as specified and directed.
400
-
-
Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m depth for foundations, sewage lines etc and n.exc 10 Sqm on plan for manholes and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
400
-
-
Excavation in trenches n.exc 1.5 m wide & depth exc 3 m but n.exc 4.5 M depth for foundations, sewage lines etc and n.exc 10 Sqm on plan for manholes and getting out inin hard/dense soil
30
-
-
Excavation in trenches n.exc 1.5 m wide & depth exc 1.5 m but n.exc 3.00 M depth for foundations, sewage lines etc and n.exc 10 Sqm on plan for manholes and getting out inin hard/dense soil
170
-
-
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exc. 25 cm depth as in any type of soil complete all as specified and directed.
540
-
-
Removing excavated materials to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m from starting point.
60
-
-
Demolition and breaking up any sewage drain pipe not exceeding 150mm bore dia set in cement mortar including bedding and haunching complete all as specified and directed.
350
-
-
Demolition and breaking up any sewage drain pipe not exceeding 300mm bore dia set in cement mortar including bedding and haunching complete all as specified and directed.
150
-
-
Demolition and breaking up any sewage drain pipe not exceeding 450mm bore dia set in cement mortar including bedding and haunching complete all as specified and directed.
30
-
-
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 150mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed. NOTE :- Pipe shall be measured and paid separately).
350
-
-
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 300mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed. NOTE :- Pipe shall be measured and paid separately).
150
-
-
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 450mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed. NOTE :- Pipe shall be measured and paid separately).
30
-
-
M&L for RCC NP-2 drain pipe 150 mm internal dia, grade ‘A’ laid in trenches and Collar/push joint all as specified and directed as in repairs.
350
-
-
M &L for RCC pipes Class NP-2 of size 300mm internal dia, laid in trenches and jointed with collar/push joint complete all as specified and directed.
150
-
-
M &L for RCC pipes Class NP-2 of size 450mm internal dia, laid in trenches and jointed with collar/push joint complete all as specified and directed.
30
-
-
Demolition of brick work/stone masonry built in cement mortar of any description
40
-
-
M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 (for manhole) all as specified and directed as
40
-
-
Taking down cement plaster on brick, stone or concrete surface including racking out joints hacking for key scrubbing down with water to receive plaster including removal of rubbish, etc complete all a specified.
130
-
-
M&L for Rendering in cement mortar 1:4, 15mm thick on brick walls or concrete finished even and smooth, (without using extra cement) as external surfaces of manholes as in repairs all as specified and directed.
330
-
-
Preparation of new plastered surface and applying three coats of white wash etc complete all a specified.
30
-
-
S & Fixed in repairs PVC (SWR) pipes 110mm bore confirming to IS-13592-1992 type 'B' single socketed, in any length with rubber ring joints fixed to walls with PVC clamp all as specified & directed.
156
-
-
S & Fixed in repairs PVC (SWR) pipes 75mm bore confirming to IS-13592-1992 type 'B' single socketed, in any length with rubber ring joints fixed to walls with PVC clamp all as specified & directed.
80
-
-
S&F in repairs PVC (SWR) bend any radius, 110 mm dia with access door complete all as specified and directed by the Engr-in-Charge
25
-
-
S&F in repairs PVC (SWR) bend any radius, 75 mm dia with access door complete all as specified and directed by the Engr-in-Charge
20
-
-
S&F in repairs, PVC (SWR) branch pipe, 110mm dia single (single ‘Y’) equal or un equal with access door complete all as directed.
15
-
-
S&F in repairs 110 mm dia PVC (SWR) junction single (T-Junction) equal or un equal with access door complete all as directed.
6
-
-
Demolition for reinforcement cement concrete complete all as specified and directed by the Engr-in-Charge
7
-
-
M&L for precast RCC 1:2:4 type B1 using 20mm graded stone aggregate in cover slabs including necessary form work etc for manholes covers set in CM 1:4 (reinforcement measured seperately)
7
-
-
M&L for TMT bars 6 to 8mm dia and over cut to length bent to shape required including bending and binding with and including MS wire annealed not less than 0.9mm dia complete.
581
-
-
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed by the Engr-in-Charge
8.5
-
-
M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exceeding .06 Sqm but not exceeding .11 Sqm, in floors etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match , over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-In-Charge.
25
-
-
M&L Glazed ceramic coloured designer tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 0ver 10mm thick plaster in cement mortar (1:3) complete all as specified and directed by Engr-In-Charge.
60
-
-
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed by Engr-In-Charge.
8
-
-
S & F vitreous china squatting Pan “ Orissa” Pattern , of size 580mm x 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including provn of cement concrete bedding complete as fixed in repairs complete all as specified and directed by Engr-In-Charge.
8
-
-
S&F 10 litre capacity low level PVC flushing cistern (white), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete as specified.
20
-
-
Supply and fix in repair 75 mm bore PVC (SWR) plain floor trap with CP grating complete all as specified and directed by the Engr-in-Charge
10
-
-
S&F in repairs angle cock 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and directed by the Engr-in-Charge
10
-
-
S & F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by the Engr-in-Charge
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements