Mehsana District Cooperative Milk Producers Union Limited Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 7,00,551Document Cost
Refer DocumentsTender Fee
₹ 5,551
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
89925Tender No
MDCMPUL/2024-25/551/Tender Authority
Mehsana District Cooperative Milk Producers Union Limited ViewPurchaser Address
-Website
http://tender.nprocure.com
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Civil 0042 CHECKLIST FOR CIVIL WORKS.pdf
Civil 0041 SPECIAL TERMS and CONDITIONS_KVP_08.04.2024_FINAL.pdf
551 Civil PSK BMF shed NIT.pdf
General Guidelines for E-Tender and E-Auction 150724.pdf
Vendor Registation Update Form.pdf
BOQ Items
External Lighting panel
-
-
-
[1] Milking parlour PDB
-
-
-
Cow shed-2,3,4,5 PDB
2
-
-
[16].Ett laboratory PDB
-
-
-
Utillity panel
-
-
-
SUB TOTAL
-
-
-
SAFTY ACCESSORIES
-
-
-
Supply of First Aid Box
1
-
-
Supply and Fixing of First aid chart in glassed wodden frame
1
-
-
Supply of Warning Signs
1
-
-
Supplying and fixing of 1.1 KV grade nominal 2.0 mm plus/minus 10percentage thick insulated Synthetic Mat conforming to IS 15652:2006 and meeting the requirements of IS 5216 (Part1,2&3), IS 8437, IEC-479 Pub-1, along-with suitable adhesive/ chemibound, Pu resin, waterproofing compound and sealing material as per in service recommendation as per specifications of this tender and directions of Engineer-in-Charge.Complete as
required.
1
-
-
Supply and Fixng of 440Volt danger caution board
1
-
-
Supply and Fixing of Resuscitation chart in Hindi and English Glass frame
1
-
-
SUB TOTAL
-
-
-
CABLE LAYING / TERMINATION / CABLET TRAY & STEEL STRUCTURE
-
-
-
Supply and Laying horizontally and vertically of XLPE insulated cables of following sizes on cable trays, supported on steel structures, in ready made trenches and / or to pull-through pipes. The rates shall include Installation, testing and commissioning of a G.I. saddles / clamps, saddle bars, etc, including transportation from owner's site store to the place of installation, unpacking and return the cable drums to site stores with all labour and materials as per the standard specifications, drawings and directions of 'Engineer-in-charge.
-
-
-
6sqX3C CU XLPE
-
-
-
2.5sqX4C CU XLPE
840
-
-
4sqX4C CU XLPE
-
-
-
6sqX4C CU XLPE
-
-
-
10sqX3C AL XLPE
10
-
-
10sqX4C AL XLPE
-
-
-
16sqX4C AL XLPE
-
-
-
25sqX4C AL XLPE
-
-
-
50sqX3.5C AL XLPE
-
-
-
120sqX3.5C AL XLPE
-
-
-
300sqX3.5C AL XLPE
-
-
-
Supply & Termination of XLPE insulated cables of different sizes and connection of the Leads including supply of weatherproof single / Double compression type cable glands and tinned copper lugs, including cutting / stripping of cable insulation, Installation, testing and commissioning of cable glands, crimping of the cable cores, marking with wire number ferrules, etc., including all labour and materials, as per standard specifications and directions of 'Engineer-in-charge.
-
-
-
6sqX3C CU XLPE
-
-
-
2.5sqX4C CU XLPE
64
-
-
4sqX4C CU XLPE
4
-
-
6sqX4C CU XLPE
-
-
-
10sqX3C AL XLPE
4
-
-
10sqX4C AL XLPE
-
-
-
16sqX4C AL XLPE
-
-
-
25sqX4C AL XLPE
-
-
-
50sqX3.5C AL XLPE
-
-
-
120sqX3.5C AL XLPE
-
-
-
300sqX3.5C AL XLPE
-
-
-
Excavation and Back filling work
-
-
-
Excavation and back filling of cable trenches required for laying the cables directly buried in the ground. The depth shall be app. 0.7mtr
-
-
-
Supply and labour charges for spreading of sand and laying of bricks
-
-
-
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original
-
-
-
200mm Dia
-
-
-
100MM Dia
-
-
-
Constructing manhole 230 mm thick brick masonry with cement mortar (1:5) as per ISI with 150 mm thick 1:3:6 P.C.C. bedding, necessary benching in concrete (M-15) and 20 mm thick smooth cement plaster (1:4) from inside, C.I. steps as necessary and rough cement plaster 20 mm thick in c.m. 1:4 outside, with 150 kg. Full size C.I. manhole cover and frame (Approved Make) including all excavation in all soil types, refilling sides in layers with selected earth ramming and consolidating, removing away surplus soil or dumping it on site as directed.900mmX900mm Chamber
-
-
-
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable cable. below ground / road surface for enclosing cable
-
-
-
120mm Outer Dia
-
-
-
63mm Outer Dia
-
-
-
40mm Outer Dia
-
-
-
Supply and installation of following sizes of pre-fabricated HDGI Perforated type cable tray type cable tray along with coupler plates, 90 bends, Tees,Reducer etc, necessary nut-bolts / washers and other hardware etc.
-
-
-
100mm (W) x 50mm(H) x 2mm (THK) Cable tray
25
-
-
200mm (W) x 50mm(H) x 2mm (THK) Cable tray
100
-
-
SITC of Fabrication work with appropriate size of MS angle ,C cahnnel for Cable tray Support scope also include with Two coat of Red Oxide and 2coat of Oil paint with Required Nutbolt, Anchor Fishnor etc.
75
-
-
SUB TOTAL
-
-
-
EARTHING
-
-
-
Supply, installation, testing & commissioning of Maintenance Free earthing as per specification, drawing and as per the instruction of Engineer-in-charge. The unit rate shall include Excavation & backfilling, copper bonded rod, filled with high conductive and corrosion resistant crystalline mixture and Backfill Compound around electrode.
-
-
-
50mm DIA x 3mtr long GI Type maintance free Earthing With Ready made RCC precast Earthing chamber
4
-
-
17mm DIA x 3mtr long CU Type maintance free Earthing With Ready made RCC precast Earthing chamber
-
-
-
SITC of G.I./Copper earthing loop / grid conductors/Cu. Cables of following sizes along the cable trenchs / cable trays / on the wall or structures / buried in ground Installation shall include the welding at joints and providing anti corrosive point (black butimine) at the welded portion, Green Color Sleeve required threwout strip and clamping using Insulator clamps to avoide direct connection to structure and necessary hardware and materials as per standard drawings, specifications and directions of Engineer-in-charge.
-
-
-
25 x 6 mm CU STRIPS
-
-
-
25 x 6 mm G.I. STRIPS
40
-
-
2.5sqmm CU Flexible Wire with pvc pipe
20
-
-
6sqmm CU Flexible Wire with pvc conduit
10
-
-
SUB TOTAL
-
-
-
DISTRIBUTION BOARD
-
-
-
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (A) single phase incoming and horizontal single phase outgoing (b) sheet steel double door (IP-43)
-
-
-
(i)8 way
2
-
-
(ii)12 way
-
-
-
(B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) (b) sheet steel double door (i)6 way
-
-
-
(ii)8 way
-
-
-
(iii)12 way
-
-
-
MCB 's and its Accessories providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
13
-
-
(A)40 Amp.
-
-
-
(B)63 Amp
-
-
-
providing and erecting Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed (i) 25 Amps.DP
-
-
-
(ii) 40 Amps.DP
2
-
-
(iii) 63 Amps.DP
-
-
-
Supply installation testing and Commisioning of 32A 3-PH Industrial Plug Socket with Mounting Box, Socket,TOP and FP MCB with MS powder coating Front Plate
2
-
-
Supply installation testing and Commisioning of 16A 1-PH Industrial Plug Socket with Mounting Box, Socket,TOP and DP MCB MS powder coating Front Plate
2
-
-
Supply installation testing and Commisioning of 40/63 A FP MCB with MS Enclouser
3
-
-
Supply installation testing and Commisioning of 16/20/25/32 A FP MCB with weather Proof Juntion Box
1
-
-
Supply installation testing and Commisioning of 20/32 A DP MCB with MS Enclouser
-
-
-
SUB TOTAL
-
-
-
MAINS (Point wiring)
-
-
-
For Light Points /fan point/ wall fan / 6A 3 Pin Plug
-
-
-
DB to SB - 2.5 sqmm for Phase & Neutral & 1.5sqmm Earth
-
-
-
MCB / SB to Point - 1.5 sqmm for Phase & Neutral & Earth
-
-
-
For 6A plug point
-
-
-
1.5 sqmm for Phase, Neutral & Earth
-
-
-
For 6/10/16A general purpose plug point
-
-
-
2.5 sqmm for Phase, Neutral & 1.5 sq. mm Earth
-
-
-
For 16A plug point for A/C and Geyser
-
-
-
2.5 sqmm for Phase, Neutral & 1.5 sq. mm Earth
-
-
-
For 20/32A plug point
-
-
-
- 4 sqmm for Phases, Neutral & 2.5 sq. mm Earth
-
-
-
FROM DB TO VRV AC INDOOR UNIT- 1.5 sqmm for Phases, Neutral & 1.5 sq. mm Earth
-
-
-
For INDUVIDUAL AC
-
-
-
FROM DB TO AC Switch To INDOOR UNIT- 4.0 sqmm for Phases, Neutral & 2.5 sq. mm Earth
-
-
-
Supply installation testing and Commisioning of Primary Light point controll with 1.5sqmm of (P+N+E) wire in PVC conduit controll by 1nos of 5A switch. (Length SB to Point-5mtr)
20
-
-
Supply installation testing and Commisioning of Secondary Light point controll with 1.5sqmm of (P+N+E) wire in PVC conduit controll by from above point. (Length Primary Point to Sec.Point-5mtr)
15
-
-
Supply installation testing and Commisioning of FAN point controll with 1.5sqmm of (P+N+E) wire in PVC conduit controll by 1nos of 5A switch and 2M Fan Regulator. (Length SB to Point-5mtr)
-
-
-
Supply installation testing and Commisioning of Exhust Fan point controll with 1.5sqmm of (P+N+E) wire in PVC conduit controll by from above point.(Length SB to Point-5mtr)
-
-
-
Supply installation testing and Commisioning of 15A Plug Point Controll by 15A indicating Switch
-
-
-
Supply installation testing and Commisioning of Ac point controll by 15A Switch indicating Switch
-
-
-
Supply installation testing and Commisioning of 5A Plug Point Controll by 5A Switch
2
-
-
Supply and Labour charges for laying of 1.5sqmm (p+N), 1.5sqmm ( E) wire in PVC conduit
-
-
-
Supply and Labour charges for laying of 2.5sqmm (p+N), 1.5sqmm ( E) wire in PVC conduit
74
-
-
Supply and Labour charges for laying of 4.0sqmm (p+N), 2.5sqmm ( E) wire in PVC conduit
-
-
-
Labour charges for Installaation testing and Commisioning of LED COB / PROFILE LIGHT / Surface / Tubelight Lights / Exhaust Fan
-
-
-
Supply and labour charges for Fixing of AnchorFishnor with Appropriate size of Fan Rod
-
-
-
SITC of laying of 2.5sqmmX4C CU XLPE Armoured Cable for Highbay Lights
-
-
-
SITC of Fixing of 4Way IP 66 NON FLP Junction Box suitable current rating upto 32A / 440V.
-
-
-
SITC of Making End Connection of 1.5/2.5sqmmX4C CU Cable
-
-
-
Labour charges for Installaation testing and Commisioning of Ceiling Fan
-
-
-
Labour charges for Installation,Testing and commisioning of 150Wt LED Flood lights
-
-
-
Buzzer point controlled by Bell push with modular type buzzer same make as switch
-
-
-
SUB TOTAL
-
-
-
Light Fixtures
-
-
-
Supply charges for Fixing Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.9, THD 15%,
CCT 6000K to 6500K, Luminaire efficacy 85 lumens/watt ,LED LED driver efficiency 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
-
-
-
Supply of 15wt led COB light Color temp-4000k.
-
-
-
Supply and Installation of 18WT led Surface / Recess light colour temp -6000K, Lumens fixture Should be made with Dia cast Aluminium body output -90lumens / watt
-
-
-
Supply charges for 40Wt LED Tubelight colour Temp-6000K, Fixture Lumens Should be -1800 made of Aluminium Body.
-
-
-
Supply and installation of 10WT led bulb for White colour temp -6500K, Lumens fixture Should be 80lumens / watt .
-
-
-
Supply and installation of 24W LED Recess Mounted 1'X1' non clean Panel Light, 90lumnes per watt output, Output Color Temp-6000k fixture
-
-
-
Supply and installation of 24W LED Recess Mounted Bottom Opening 1'X1' clean Panel Light, 90lumnes per watt output, Output Color Temp-6000k fixture
-
-
-
Supply & installation of bracket light, fabricated from mild steel medium class pipe ERW type, of 50 mm NB ,1.8 m long having 500 mm vertical &1300 mm bent, with MS/ Thermoplastic switch box of apprx. size 250x200x80 mm having 30A 4 way connector for power, 30A 4 way connector for neutral, 10 A SP MCB. and concealed/ surface conduit( Maximum 5.0 m ) between MS/ Thermoplastic box and bracket for wiring .40wt
35
-
-
Supply and Installtion testing and commisioning of Fixing of 150Wt LED Highbay lights with Fixing of BOX pipe with 2ncoat of Paint and Red Oxide. Approx length of pipe 1.5mtr
-
-
-
Sitc of Fixing of 150wt LED Flood Light
-
-
-
SITC of RATING of 900MM DIA 3 PH IND AIR circulation wall fan make ALMONARD
32
-
-
Supply for BLDC Ceiling Fan 1200mm dia
-
-
-
Supply of 12inch Dia Metal Body Heavy Duety Exhaust Fan
-
-
-
SUB TOTAL
-
-
-