Military Engineer Services Tender

View complete overview of Goa MES Tender

Military Engineer Services - MES Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date2 Sep 2024
Closing Date30 Sep 2024
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and charging refrigerant gas F-12/R-134 up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas including leakage testing if any complete all as specified and directed for the following capacity of water cooler / refrigerator/Deep freezer :- (a) Water cooler of 40 to 150 ltrs capacity.

12

-

-

... More
(b) Refrigerator 165 to 310 Ltr capacity

8

-

-

... More
(c) Deep Freezers 200 to 425 ltrs capacity

2

-

-

... More
Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed for the following capacity of water cooler / refrigerator/Deep freezer :- Make :Emerson, Kirloskar, Voltas (a) Water coolers of 40 to 150 ltrs capacity

9

-

-

... More
(b) Refrigerator 165 to 310 Ltr capacity

4

-

-

... More
(c) Deep Freezers 200 to 425 ltrs capacity

1

-

-

... More
Supply and replace starting relay as per existing suitable for the following capacity of water cooler / refrigerator/Deep freezer:- (a) Water coolers 40 to 150 ltrs capacity

10

-

-

... More
(b) Refrigerator 165 to 310 Ltr capacity

10

-

-

... More
(c) Deep Freezers 200 to 425 ltrs capacity

3

-

-

... More
Supply and replace thermostats as per existing suitable for the following capacity of water cooler / refrigerator/Deep freezer:- (a) Water coolers 40 to 150 ltrs capacity

18

-

-

... More
(b) Refrigerator 165 to 310 Ltr capacity

12

-

-

... More
(c) Deep Freezers 200 to 425 ltrs capacity

3

-

-

... More
Supply and replace condenser unit including making of all connections as per existing suitable for the following capacity of water cooler / refrigerator/Deep freezer:- (a) Water coolers 40 to 150 ltrs capacity

12

-

-

... More
(b) Refrigerator 165 to 310 Ltr capacity

8

-

-

... More
(c) Deep Freezers 200 to 425 ltrs capacity

2

-

-

... More
Supply and replace cooling coil as per existing suitable for the following capacity of water cooler / refrigerator:- (a) Water coolers of 40 to 150 ltrs capacity.

5

-

-

... More
(b) Refrigerator 165 to 310 Ltr capacity

5

-

-

... More
Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity.

10

-

-

... More
Supply and replace overload protector of the following :- (a) Water coolers/ Refrigarator upto 340 ltrs cooling capacity.

12

-

-

... More
(b) Deep freezers of upto 425 ltrs capacity.

3

-

-

... More
Supply and replace ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule of the following sizes :- Make : Leader, Jindal (a) 15mm dia

5

-

-

... More
(b) 20mm dia

5

-

-

... More
Supply and fix PVC insulated and overall PVC sheathed circular flexible 3 core 4 sqmm copper conductor cable including disconnecting and removal of old cable . Make: Grandlay/Havells/Polycab/Anchor/Finolex

270

-

-

... More
Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames as per existing suitable for the following capacity of water cooler / Deep freezer:- (a) Water coolers of any make and cap 40 to 150 ltrs.

12

-

-

... More
(b) Deep Freezers 200 to 425 ltrs capacity

2

-

-

... More
Supply, fixing, laying & testing in repairs CPVC pipes 16 mm SDR 13.5 including Plain CPVC SDR 11 fittings on walls/ceiling or laying in trenches, floors with all accessories complete all as specified and directed

50

-

-

... More
All as per item No. 29 above but 20 mm bore

35

-

-

... More
S&F in replacement of existing unsv Gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for pipe of size 15 mm bore complete all as specified and directed.

5

-

-

... More
All as per item No. 31 above but 20 mm bore

5

-

-

... More
S&F in repair bib taps, cast copper alloy with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.

8

-

-

... More
All as per item No. 33 above but 20 mm bore

5

-

-

... More
Dismantling and removing of defective burnt motor from unit and rewinding the motor with super enamel copper winding wire including replacement of worn out motor bearing, refixing and testing as per existing suitable for the following capacity of water cooler / Deep freezer:- (a) Water coolers of any make and cap 40 to 150 ltrs.

15

-

-

... More
(b) Deep Freezers 200 to 425 ltrs capacity

2

-

-

... More
Supply and replace internal wiring complete suitable for :- (a) Water coolers of any make and cap 40 to 150 ltrs.

10

-

-

... More
(b) Deep Freezers 200 to 425 ltrs capacity

2

-

-

... More
Supply and charging refrigerant gas R-22/R-32 up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas complete all as specified and directed. Make Paragon, Mefron (Note: Above second floor contractor will arrange crain / scaffolding with safety device) (a) Window type AC of capacity 1/1.5 Ton.

4

-

-

... More
(b) Split type AC 1.5/2.0 Ton capacity

78

-

-

... More
M&L for servicing of Split type AC 1.5/2 Ton capacity comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation (Note : Above second floor contractor will arrange crane / scaffolding with safety device)

310

-

-

... More
M&L for applying two coats of synthetic enamel paint using spray machine on inner and outer unit of split type AC including preparation of surface complete all as directed. (Note : Above second floor contractor will arrange crane / scaffolding with safety device)

5

-

-

... More
Supply and replace compressor sealed unit of the following appliances complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed. (Note : Above second floor contractor will arrange crane / scaffolding with safety device) Make : Emerson, Kirloskar, LG (a) Window type AC of capacity 1/1.5 Ton.

2

-

-

... More
(b) Split type AC 1.5/2.0 Ton capacity.

38

-

-

... More
Supply and replace capacitors of the following capacities for ACs Make : Siemens/ Epcos/Universal (a) 4/6 Mfd

150

-

-

... More
(b) 10 Mfd

80

-

-

... More
(c) 36 Mfd (Six Pin)

80

-

-

... More
(d) 80/100 Mfd

70

-

-

... More
(e) 120 Mfd

90

-

-

... More
(f) 45+6 Mfd Seven Pin

80

-

-

... More
M&L for cutting out worn out bottom portion and fabricating/welding properly of bottom tray with suitable size of GI plate and welding of legs including supply and fixing of suitable size of angle iron legs to match existing of split type AC Unit any capacity complete all as directed.

12

-

-

... More
Supply and replace starting relay suitable for Split type AC 1.5/2 Ton capacity complete all as directed.

50

-

-

... More
Supply and replace thermostats suitable for Split type AC 1.5/2 Ton capacity complete all as directed. Make: Danfoss, Annapooma

30

-

-

... More
Supply and replace overload protector suitable for Split type AC 1.5/2 Ton capacity complete all as directed. Make Usha, Annapooma

30

-

-

... More
Supply and replace condenser unit made of copper suitable for Split type AC 1.5/2 Ton capacity including making of all connections as specified and directed. Make :.LG, Voltas, Whirpool

35

-

-

... More
Supply and replace of evaporator coil suitable for Split type AC 1.5/2 Ton capacity complete all as directed.

12

-

-

... More
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 25/32 mm wide PVC casing and capping with all accessories such as Tee, elbow, junction box, reducers etc. including making good the disturbed wall surfaces to match with existing specification. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.

180

-

-

... More
S&F in replacement sheet metal enclosures, single pole with socket, plug top and one single pole MCB 20 Amps, 240 V complete all as specified and directed.

20

-

-

... More
S&F in replacement MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.

20

-

-

... More
Supply and replace contact unit of split type AC 1.5/2 Ton capacity.

40

-

-

... More
Supply and replace internal wiring complete suitable for Split type AC 1.5/2 Ton capacity complete all as directed.

25

-

-

... More
Dismantling and removing of defective burnt motor from Split type AC of any make and capacity 1.5/2 ton. and rewinding the motor with enamel copper winding wire incl replacement of worn - out motor bearing, refixing and testing all as directed

80

-

-

... More
Supply and replace blower/condenser fan motor complete with necessary mounting bracket and base frames for Split type AC of any make and capacity 1.5/2 ton complete all as directed. Make Crompton Greaves, Voltas, LG.

80

-

-

... More
Supply and fix in repair indoor fan unit complete suitable for cool room/cold room to match exisitng make and capacity all as directed.

2

-

-

... More
Supply and fix in repairs 15 mm dia drain pipe heavy duty PVC flexible pipe with necessary fittings of jubilee/ Split AC's/ Window AC's complete all as directed.

400

-

-

... More
Supply and fix Air filter suitable for 1.5/2.0 ton split type AC of any make all as directed.

80

-

-

... More
Supply and fix insulation for copper tubes of split type AC units, insulation type superlon of size 3/8" diameter all as directed.

80

-

-

... More
Supply and fix insulation for copper tubes of split type AC units, insulation type superlon of size 5/8" diameter all as directed.

80

-

-

... More
Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8" diameter all as directed.

80

-

-

... More
Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8" diameter all as directed.

80

-

-

... More
Taking down of Split type AC (Indoor & out door with mounting bracket & voltage stabilizer) of any capacity from existing place and Reinstalling the same in another location complete and testing & commisioning all as specified and directed Note : New spares required for replacing (mounting bracket, insulation for copper and copper tubing) shall be measured and paid seperately.

10

-

-

... More
Supply and fix PCB (circuit board) complete suitable for 1.5/2.0 ton capacity Inverter type split AC indoor unit all as directed. Make: LG, Voltas, Daikin

40

-

-

... More
Supply and fix PCB (circuit board) complete suitable for 1.5/2.0 ton capacity Inverter type split AC out door unit all as directed. Make: LG, Voltas, Daikin

50

-

-

... More
Supply and fix PCB (circuit board) complete suitable for 1.5/2.0 ton capacity non Inverter type split AC out door unit all as directed. Make: LG, Voltas, Daikin

80

-

-

... More
Supply and replace of Heating element of cold room door as directed and specified.

1

-

-

... More
Supply and replace of Thermostat of cold room door heater as directed and specified.

1

-

-

... More
S&F handle with locking facility of cold room door of existing make and size complete all as directed.

2

-

-

... More
S&F MS stand factory made for installation of condensing unit on the wall/ ground duly powder coated all as per existing size complete all as directed.

21

-

-

... More
Supply and fix in repair remote control as per existing make of any size and capacity of split AC all as directed.

20

-

-

... More
Supply and fix in repair Voltage stabilizer Capacity of 5 KVA of range 130 V to 180 V suitable for up to 2 Ton split AC all as directed. Make: V-Guard/MicroTek/Luminous.

18

-

-

... More
Supply and fix in repair indoor cooling unit with rotary fan suitable for 1.5 ton Split AC all as directed. Make: LG, Voltas, Samsung

1

-

-

... More
Supply and fix in repair indoor cooling unit with rotary fan suitable for 2 ton Split AC all as directed. Make: LG, Voltas, Samsung

1

-

-

... More
Supply and fix in repair outdoor unit with rotary fan suitable for 1.5 ton Split AC all as directed. Make LG, Voltas, Samsung

1

-

-

... More
Supply and fix in repair outdoor unit with rotary fan suitable for 2 ton Split AC all as directed. Make LG, Voltas, Samsung

1

-

-

... More
Supply and installing electrical cold room panel, three phase supply, 415 Volts, AC supply showing display temperature, voltage, current and humidity complete all as specified and directed.

1

-

-

... More
Comprehensive maintenance of electrically operated 4/6 passenger lift installed at VKD, Gomantak in reliable safe and efficient operating condition by regularly examining including attending lift in case of emergency, lubricating and adjusting the equipments and carry out planned maintenance in systematic and controlled manner suitable for serving G+3 with electric power operated doors, ARD complete by Skilled Lift Mechanic all as specified and directed

11

-

-

... More
Comprehensive maintenance of electrically operated passenger cum bed lift with a carrying cap of 15 passenger to serve (G+1) lift installed at Jeevanti Hospital, Gomantak in reliable safe and efficient operating condition by regularly examining including attending lift in case of emergency, lubricating and adjusting the equipments and carry out planned maintenance in systematic and controlled manner with electric power operated doors, ARD complete by Skilled Lift Mechanic all as specified and directed Note for Ser Item No. 1 & 2 (i) The above maintenance will include complete maintenance of existing lift by regularly and systematically examining adjusting fabricating as required for smooth and functioning of the equipment/lift. The cost of all Minor spares such as nuts bolts, cleaning accessories, lubricant oil etc. shall be deemed to be included in the rates quoted by the contractor. (ii) Contractor will prominently display his contact/mobile number inside and outside the lift on each lift for call in emergency. (iii) Major worn out/ defective part will be measured and paid seperately under respective item of Schedule.

11

-

-

... More
Supply, fixing, commissioning and testing ARD (Automatic Rescue Device) with panel complete in all respect including necessary internal wiring work, including maintenance free ARD batteries 06/8 Nos suitable for passenger cum bed lift installed at Jeevanti Hospital/ VKD including taking down old unserviceable one complete all as specified and directed.

1

-

-

... More
Supply, fixing & testing of Relay card suitable for any capacity lift installed at VKD/ Jeevanti including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing, testing and commissioning of Door sensor along with all connected accessories suitable lifts installed at VKD/Jeevanti icnluding taking down old unserviceable one complete all as specified and directed. (Make:- As per OEM recommendation).

2

-

-

... More
Supply, fixing, testing and commissioning of Door drive (door formator) suitable for lift installed at VKD/Jeevanti including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing of 3 phase power control line choke suitable for lifts installed at VKD/Jeevanti including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing of speed control DBR suitable for lifts installed at VKD/Jeevanti, Gomantak including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing of Mother board card auto door suitable for lifts installed at VKD/Jeevanti including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing of Safety card 110 V card suitable for lifts installed at VKD/Jeevanti, Gomantak including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing of SMPS -12V/3A (ADPSMEL81) suitable for lifts installed at VKD/Jeevanti, including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing of SPP (digtal Voltage protection)suitable for lifts installed at VKD/Jeevanti, Gomantak including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing of Diode Bridge Card suitable for lifts installed at VKD/Jeevanti, including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing of Contactor 110 V (ADP18FEL017-18) suitable for lifts installed at VKD/Jeevanti, Gomantak including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing Voice annoucement card suitable for lifts installed at VKD/Jeevanti, including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing & testing control main Transformer suitable for lifts installed at VKD/Jeevanti, Gomantak including taking out old unserviceable one complelte all as directed.

1

-

-

... More
Supply, fixing, testing of Landing Operating Panel (LOP) assembly along with all connected accessories suitable for lifts installed at VKD/Jeevanti including taking out old unserviceable one complelte all as directed. (Make:- As per OEM recommendation).

2

-

-

... More
Supply, fixing, testing of Car inside / outside button suitable for lifts installed at VKD/Jeevanti, Gomantak including taking out old unserviceable one complelte all as directed. (Make:- As per OEM recommendation).

4

-

-

... More
Supply, fixing, testing of Break coil suitable for lifts installed at VKD/Jeevanti, Gomantak including taking out old unserviceable one complelte all as directed. (Make:- As per OEM recommendation).

1

-

-

... More
S & F recess mounted LED cabin lights 6W (round) cutout size as per site requirement complete all as directed.

12

-

-

... More
M&L for complete servicing of Solar Water Heater thermosyphonic type of capacity 1250 ltrs including cleaning of main tank, Solar power module/ Solar Panel Reflectors including checking & repairing leakage of inlet/ outlet pipes of Solar Water Heater complete installed at INHS Jeevanti all as specified and directed.

4

-

-

... More
Supply and fixing heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as specified and directed .

2

-

-

... More
Supply and fixing thermostat for heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as all as specified and directed .

2

-

-

... More
M&L for complete servicing of Solar Water Heater thermosyphonic type of capacity 100 LPD including cleaning of main tank, Solar power module/ Solar Panel Reflectors including checking & repairing leakage of inlet/ outlet pipes of Solar Water Heater complete installed at MNS Block, Gomantak all as specified and directed.

3

-

-

... More
M&L for servicing and cleaning of exhaust and fresh air ducting/ blower and SS hood chimney inside/outside system any size of forced ventilation system after dismantling nuts and bolts by using hot water, detergent and SS polish and fresh air blower fan and painting with synthetic enamel paint of existing colour by spraying, including filling cavities with filler including replacement of micro filter of 20/90 microns (as per existing filter) including refixing the same in original position with new nuts/bolts and washers at GNA (O) mess, ships galley, DSC galley & 2 W det Ship Gallley complete all as specified and directed. Note:- One job will include carrying out complete activity in all the locations mentioned in this item.

2

-

-

... More
S & F Direct on line Starters 415V, up to 5 HP, relay range 9-15 Amps 50 Hz, 3 phase complete all as specified and directed. Make Havells/L&T/scheider

2

-

-

... More
S & F MCCBs for motor protection for current rating 100 Amp, 25 KA, 4 pole, 415V, AC complete all as specified and directed. Make: L&T /Havells/scheider

2

-

-

... More
S & F Electronic motor protection relay with earth fault protection for overload current range 16-44 Amps / 32-88 Amps, 240 V AC complete all as specified and directed. Make: L&T Model MPR 300 or equivalent in Havells/Scheider

2

-

-

... More
S & F Surge Protection devices (SPDs) for protection against indirect lighting and switching surges type 1+2 I max 50 KA, 3P+N complete all as specified and as directed.

1

-

-

... More
S & F Aluminium fresh Grills of size 300 x 150 mm complete all as per existing at DSC, Gomantak Galley complete all as specified and directed.

3

-

-

... More
S&F fresh air filter grill of size 550 x 550 mm complete all as per existing at DSC, GNA Officers Mess Gomantak & 2 W det Galley.complete all as specified and as directed.

6

-

-

... More
S & F Aluminium fresh Grills of size 400 x 150 mm complete all as per existing at GNA Officers Mess, Gomantak Galley.complete all as specified and as directed.

8

-

-

... More
S & F Aluminium fresh Grills of size 300 x 200 mm complete all as per existing at 2W Det Galley.complete all as specified and as directed.

2

-

-

... More
Supply, installation, balancing, testing and commissioning of site fabricated GI sheet metal rectangular/ round ducting complete with neuperene rubber gaskets, elbows, bends, slip on flanges, GI thread rod, vanes, in and including fixing and supports meterials as per site requirement etc. of size 22 guage GI Sheet complete all as specified and as directed.

30

-

-

... More
S&F SS enclosure for MCCBs suitable to accommodate upto 70 sqmm 3.5 core XLPE cable complete all as specified and as directed.

1

-

-

... More
Supply & fixing 3 pole power contactors MNX-35, 415 V complete all as specified and as directed.

6

-

-

... More
Supply & fix in replacement relay suitable for Laundry, exhaust blower etc complete all as specified and as directed.

4

-

-

... More
Maintenance, Servicing and attending complaints in case of emergency or breakdown, rectification of fault of Mechanical laundry consisiting of Front loding washing machine 35 KG Capacity electrically operated Basket size 950 x 500 mm 1HP wash motor with 36 RPM drain water inlet 25 mm and drain outlet 75 mm heating coil 12 KW door opening size 500 mm and overall dimention 1120x 1440x 1730 mm, Hydro Extractor Capacity 15 KG, 3 HP drive motor, Basket size 550 x 300 mm, Extract speed 1000 RPM, Drain 65 mm and overall dimention 800 x 1050 x 1110 mm, Drying Thumbler 30 KG capacity Basket size 950 x 950 mm, 1HP drive motor, 1 HP blower motor electrical heating coil 18/ 24 KW overall dimention 1060 x 1570 x 1980 mm, Flat bed press head and buck size 1500 x 750 mm 1HP suction blower and 18 KW electrical heating coil over all dimention 1600 x 1570 x 1280 mm, Air Compressor of 2HPand all other connected work services, installed at INHS Jeevanti. Note: Major worn out/ defective part will be measured and paid seperately under respective item of Sch.

11

-

-

... More
Supply & Fixing in replacement of Microprocessor card for dryer/ washer complete all as specified and as directed.

1

-

-

... More
Supply & Fixing in replacement of Emergency swict /limit switch for dryer/ Washer complete all as specified and as directed.

1

-

-

... More
Supply & Fixing in replacement of Contactor Rev forwarder for dryer washer complete all as specified and as directed.

1

-

-

... More
Supply & Fixing in replacement of Contactor for heater for dryer/ washer complete all as specified and as directed.

1

-

-

... More
Supply & Fixing in replacement of transformer for dryer/ washer complete all as specified and as directed.

1

-

-

... More
Supply & Fixing in replacement of single phase preventor for dryer/ washer complete all as specified and as directed.

1

-

-

... More
Supply & Fixing in replacement of MCB switch (part No SDT-30-008 ) for dryer/ washer complete all as specified and as directed.

1

-

-

... More
Supply & Fixing in replacement of heater for dryer/washer complete all as specified and as directed.

1

-

-

... More
Supply & Fixing in replacement of glass wire for dryer / washer complete all as specified and as directed.

10

-

-

... More
Supply & Fixing in replacement of main bearing block/sleeve for dryer/ washer complete all as specified and as directed.

3

-

-

... More
Supply & Fixing in replacement of contactor any type for Washer/dryer complete all as specified and as directed.

1

-

-

... More
Supply & Fixing in replacement of drive valve /belts for Washer /dryer complete all as specified and as directed.

1

-

-

... More
Comprehensive maintainance and attending complaint in case of emergency or breakdown, Rectification of minor fault of Oil fired Incinerator of burning capacity 10kg/hr with all its accesories ( Primary and Secondary Burner of 0.5 HP, SP fully automatic mono block type, pressure jet with sequential controller, flame monitor, solenoid valves built in blower and motor fuel pump, voltage ignition transformer, ID FAn centrifugal type 3 Phase 5 HP, Forced draft fan centrifugal type SP, 1HP, Recirculation pump 2 in Nos of 0.5 &0.4 HP, complete electical controll panel installed at INHS Jeevanti complete all as specified & directed. Note: Major worn out/ defective part will be provided and paid seperatly. Make of incinerator- J J Hotmax, Hyderabad.

11

-

-

... More
M&L for painting of complete oil fired incinerator installation comprising of Primary and secondary chamber, emergency vent, Ventury scrubber, Recirculation tank, chimney (stack). complete unit painted externally with two coats of heat resistant silver coloured aluminium paint over a coat of primer. Electrical panel and the fuel oil tank shall be painted with two coats of synthetic enamel paint ove a coat of primer complete all as specified and directed.

1

-

-

... More
Material and labour for re-winding of electrical motor of Ventilation system/Mechanical laundary/fire fiting system with super enameled copper winding wire of required gauge by providing necessary insulating material, baking, varnishing etc complete all as manufacturing instruction and as directed. Note:- Rate quoted by contractor shall be included dismantling removing, transporting, re-fixing testing and commissioning all as directed.

30

-

-

... More
Supply and fix ball bearing suitable for up to 7.5 HP capacity motors/pumps after removal of old unserviceable bearing and making proper alignment and testing all as specified and directed by Engr-in-Charge

5

-

-

... More
Comprehensive maintenance including monthly inspection, throughly check, detection of fault, repairing the minor fault and replacement of defective spare part if any including cleaning of dust from smoke detector and checking of contunuity by the skilled technician/ service Engr to Fire Alarm system with 10 Fire zone and testing on completion of said job upto the full sasisfication of Engr-in charge. Note : Spare/ part for replacement will be paid and measured seperatly.

11

-

-

... More
Supply & Fixing in replacement of smoke detector complete all as directed.

15

-

-

... More
Supply & Fixing in replacement of Pro detection panel for any zone out of fire zone of fire alarm system suitable for NIH complete all as directed.

1

-

-

... More
Supply & Fixing in replacement of fire/flame detector (Repeater) complete all as directed.

15

-

-

... More
Supply and fix in replacement addressable mannual call point break glass type with alarm LED complete all as directed.

4

-

-

... More
M&L for carrying comprehensive maintenance and technical services for 10 KVA UPS installed at Jeevanti Hospital, Gomantak. consisting of following (a) The service technician shall visit the UPS installation site for periodic preventive maintenance, checkup of the UPS system and the batteries every month. During this the system shall be cleaned and general performance will be checked. (b) DC backup source will be maintained properly by applying white petrolium jelly, checking/servicing of batteries etc as applicable. (c) Apart from the periodic preventive maintenance visits all break down calls on system arised during the contract period shall be attended quickly to keep the UPS system in operational condition. (d) Cost of all the minor spares required to put the UPS in working condition shall be borne by the contractor during the contract period and the rates for the same is deemed to be included in the rates quoted by the Contractor. (e) Response time during normal working hours shall be 4 hrs from the time of receipt of complaint and the resolution time shall be maximum 48 hrs based on the nature of complaint and replacement of components and parts etc. (f) Major Parts required for repair / replacement shall be measured and paid for seprately under relevant items of Schedule.

11

-

-

... More
Supply & Fixing in repair control card for AC to DC.

2

-

-

... More
Supply & Fixing in repair Drive card for internal circuit.

2

-

-

... More
Supply & Fixing in repair IGBT card 600Volts.

2

-

-

... More
Supply & Fixing in repair VIGBT 150A, 600 Volts.

2

-

-

... More
Supply & Fixing in repair control card for 5/10 KVA UPS.

2

-

-

... More
Supply & Fixing in repair sealed maintenance free Battery 12V, 42 AH for UPS.

16

-

-

... More
Supply & fixing in repair Cooling fan of UPS for capacity upto 10 KVA.

1

-

-

... More
Supply & Fixing in repair mother board of 10 KVA UPS Normal /Solar type.

2

-

-

... More
Inspecting, thoruoghly check, detection of fault, repairing the minor fault and replacement of defective spare part if any including cleaning of battery bank terminal and applying petrolium jelly on terminal by the skilled technician/ service Engr to solar UPS of capacity upto 10 KVA capacity testing on completion of said job upto the full sasisfication of Engr-in charge. Note : Spare/ part for replacement will be paid and measured seperately.

10

-

-

... More
Supply & fixing Street Light 60 W with cast aluminium housing, toughened glass diffuser, secondary optics, IP66, including suitable size of GI pipe 1.2 m long bend to required shape with GI elbow, MS clamps, nut, bolt and washers making electrical connection to the fitting with Suitable size of service wire complete as as directed.

25

-

-

... More
S & F LED flood light luminaire 3rd Generation 210 W Pressure die cast housing, IP 66 rating making electrical connection to the fitting of high mast light with suitable size of wire including taking down of old defective fittings complete all as specified and directed. MAke:- Bajaj Cat Part No.BJFL 240W LED or equivalent in Crompton/ Havells

3

-

-

... More
S & F solar outdoor gate lights 10 W Square/round complete all as speicifed and directed. Make Luker/Havells/Bajaj

6

-

-

... More
Supply & Fixing in repair sealed maintenance free Battery 12V, 7 AH complete al as specified. Make : Exide /Amaron/Luminous

7

-

-

... More
Testing of lifts by lift Inspector authorized by Goa State Govt. complete all as specified and as directed.

4

-

-

... More
Supply only LED bulb 0.5 Watts Color WH/WW/BL/GR/YL/RD with base B22 all as specified and directed.

30

-

-

... More
Supply only LED bulb 3 Watts Color WH/WW with base B22 screw /thread type all as specified and directed

40

-

-

... More
Supply only LED bulb 7/9 Watts Color WH/WW (B22 & E27) screw /thread type all as specified and directed

40

-

-

... More
S & F LED flood light luminaire 20 W multicolours including taking down of old defective fittings Complete all as specified and directed. Make Luker/Havells/Bajaj

4

-

-

... More
Supplying, fixing and testing in replacement of unserviceable fire hydrant fanged type landing valve, oblique type, single outlet with hose copling adaptor of size 63 mm bore made of gun metal with female mouth and cast iron wheel and instantaneous spring lock, blank cap with chain confirmin to IS:5290 complete all as specified and as directed.

1

-

-

... More
Supply & installation in replacement of 10 KVA UPS 3 phase to 3 phase online UPS with 240 Volt DC batteries, True online conversion IGBT based 10 KVA UPS with inbuilt isolation transformer 3ph I/P, 3 phase O/P and internal manual by pass switch min backup is 3 to 4 hrs with 16 Nos, 42 Ah batteries 02 year warranty complete all as specified and as directed. Make:- Luminous/ Microtek/ Schneider Electric

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.