Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Dec 2023
Closing Date15 Jan 2024
Tender Amount₹ 43,97,53,937 
Notes
Download

Costs

  • EMD

    ₹ 53,97,539
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

3050

4864750

1595

... More
Supply of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

240

270480

1127

... More
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

9

5085000

565000

... More
Supply of 11KV RMU 4 Way,630A,with 3LBS +1 CB

4

2840000

710000

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

20

176800

8840

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

3

88677

29559

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 185sq.mm

12

94476

7873

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 185sq.mm.

6

162474

27079

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

12

80772

6731

... More
Supply of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

12

121824

10152

... More
Supply of Cable route Markers (for entire route length)

23

12144

528

... More
Supply of Warning Tapes (for entire route length) as per technical specification and drawing.

1.45

21750

15000

... More
Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV underground cables.including double run

137.5

298375

2170

... More
Laterite Masonary Works Rubble Packing with hard laterite stone under floors including watering rammaing and comsolidating etc in pipeline trench and other foundations complete. Single circuit 11kv cable trench(0.2*0.7*1.0)

84

185724

2211

... More
Design, Supply of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

100

48800

488

... More
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

3000

405000

135

... More
Supply of Bricks for cable separation

1750

16625

9.5

... More
Design, Supply of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

36

60516

1681

... More
Supply of HDGI flat of size 25x5 mm for earthing

310

35960

116

... More
Supply of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

26

172432

6632

... More
ERECTION, TESTING AND COMMISSIONING

-

-

-

... More
E,T&C of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

1800

615600

342

... More
E,T&C of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

3050

802150

263

... More
E,T&C of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

240

47760

199

... More
E,T&C of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

9

87480

9720

... More
E,T&C of 11KV RMU 4 Way,630A,with 3LBS +1 CB

4

38880

9720

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

20

50960

2548

... More
E,T&C of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

3

11139

3713

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 185sq.mm

12

30576

2548

... More
E,T&C of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 185sq.mm.

6

20700

3450

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

12

30456

2538

... More
E,T&C of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

12

31776

2648

... More
E,T&C of Cable route Markers (for entire route length)

23

5888

256

... More
HDD Drawing of HT/LT UG Cables by trenchless technology by adopting HDD method.The work includes preparation of site ,boring as well as drawing of cables in normal/hard soil including soft ,watery and sandy soil with minimum 8inch bore size with HDPE pipe

500

1400000

2800

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kind of soil including Single run (1.1*.45*1100) + (1.1*.55*350) double run

756.25

353925

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge including double run

618.75

74250

120

... More
Disposal of surplus excavated soil/material by mechanical transportation including loading and unloading,stacking/leveling as directed within a distance of 3000mts

137.5

17300

125.82

... More
Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

100

7700

77

... More
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

3000

180000

60

... More
Erection of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

36

6552

182

... More
E,T&C of HDGI flat of size 25x5 mm for earthing

310

14880

48

... More
Providing,testing&commissioning of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

26

81666

3141

... More
SCHEDULE 2

-

-

-

... More
Supply/Material

-

-

-

... More
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

6700

15664600

2338

... More
Supply of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

3900

6220500

1595

... More
Supply of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

480

540960

1127

... More
Supply of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

6

3690000

615000

... More
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

22

12430000

565000

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

56

495040

8840

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

15

443385

29559

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 185sq.mm

14

110222

7873

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 185sq.mm.

6

162474

27079

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

25

168275

6731

... More
Supply of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

24

243648

10152

... More
Supply of Cable route Markers (for entire route length)

79

41712

528

... More
Supply of Warning Tapes (for entire route length) as per technical specification and drawing.

5.9

88500

15000

... More
Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV underground cables.including double run

537

1165290

2170

... More
Laterite Masonary Works Rubble Packing with hard laterite stone under floors including watering rammaing and comsolidating etc in pipeline trench and other foundations complete. Single circuit 11kv cable trench(0.2*0.7*1.0)

289.33

639708

2211

... More
Design, Supply of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

200

97600

488

... More
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

10334

1395090

135

... More
Supply of Bricks for cable separation

1500

14250

9.5

... More
Design, Supply of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

48

80688

1681

... More
Supply of HDGI flat of size 25x5 mm for earthing

310

35960

116

... More
Supply of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

62

411184

6632

... More
ERECTION, TESTING AND COMMISSIONING

-

-

-

... More
E,T&C of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

6200

2120400

342

... More
E,T&C of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

3900

1025700

263

... More
E,T&C of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

480

95520

199

... More
E,T&C of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

6

58320

9720

... More
E,T&C of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

22

213840

9720

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

56

142688

2548

... More
E,T&C of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

15

55695

3713

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 185sq.mm

14

35672

2548

... More
E,T&C of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 185sq.mm.

6

20700

3450

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

25

63450

2538

... More
E,T&C of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

24

63552

2648

... More
E,T&C of Cable route Markers (for entire route length)

79

20224

256

... More
HDD Drawing of HT/LT UG Cables by trenchless technology by adopting HDD method.The work includes preparation of site ,boring as well as drawing of cables in normal/hard soil including soft ,watery and sandy soil with minimum 8inch bore size with HDPE pipe

500

1400000

2800

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kind of soil including Single run (1.1*.45*5600) + (1.1*.55*300) double run

2953.5

1382238

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge including double run

2416.5

289980

120

... More
Disposal of surplus excavated soil/material by mechanical transportation including loading and unloading,stacking/leveling as directed within a distance of 3000mts

537

67565

125.82

... More
Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

200

15400

77

... More
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

10334

620040

60

... More
Erection of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

48

8736

182

... More
E,T&C of HDGI flat of size 25x5 mm for earthing

310

14880

48

... More
Providing,testing&commissioning of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

62

194742

3141

... More
SCHEDULE 3

-

-

-

... More
Supply/Material

-

-

-

... More
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

9440

22070720

2338

... More
Supply of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

500

797500

1595

... More
Supply of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

500

563500

1127

... More
Supply of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

5

3075000

615000

... More
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

24

13560000

565000

... More
Supply of 11KV RMU 4 Way,630A,with 3LBS +1 CB

2

1420000

710000

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

68

601120

8840

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

26

768534

29559

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 185sq.mm

2

15746

7873

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 185sq.mm.

1

27079

27079

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

29

195199

6731

... More
Supply of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

25

253800

10152

... More
Supply of Cable route Markers (for entire route length)

103

54384

528

... More
Supply of Warning Tapes (for entire route length) as per technical specification and drawing.

7.19

107850

15000

... More
Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV underground cables.including double run

682.1

1480157

2170

... More
Laterite Masonary Works Rubble Packing with hard laterite stone under floors including watering rammaing and comsolidating etc in pipeline trench and other foundations complete. Single circuit 11kv cable trench(0.2*0.7*1.0)

417.2

922429

2211

... More
Design, Supply of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

250

122000

488

... More
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

14900

2011500

135

... More
Supply of Bricks for cable separation

8750

83125

9.5

... More
Design, Supply of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

78

131118

1681

... More
Supply of HDGI flat of size 25x5 mm for earthing

320

37120

116

... More
Supply of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

64

424448

6632

... More
ERECTION, TESTING AND COMMISSIONING

-

-

-

... More
E,T&C of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

8940

3057480

342

... More
E,T&C of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

500

131500

263

... More
E,T&C of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

500

99500

199

... More
E,T&C of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

5

48600

9720

... More
E,T&C of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

24

233280

9720

... More
E,T&C of 11KV RMU 4 Way,630A,with 3LBS +1 CB

2

19440

9720

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

68

173264

2548

... More
E,T&C of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

26

96538

3713

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 185sq.mm

2

5096

2548

... More
E,T&C of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 185sq.mm.

1

3450

3450

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

29

73602

2538

... More
E,T&C of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

25

66200

2648

... More
E,T&C of Cable route Markers (for entire route length)

103

26368

256

... More
HDD Drawing of HT/LT UG Cables by trenchless technology by adopting HDD method.The work includes preparation of site ,boring as well as drawing of cables in normal/hard soil including soft ,watery and sandy soil with minimum 8inch bore size with HDPE pipe

500

1400000

2800

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kind of soil including Single run (1.1*.45*5440) + (1.1*.55*1750) double run

3751.55

1755725

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge including double run

3069.45

368334

120

... More
Disposal of surplus excavated soil/material by mechanical transportation including loading and unloading,stacking/leveling as directed within a distance of 3000mts

682.1

85821

125.82

... More
Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

250

19250

77

... More
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

14900

894000

60

... More
Erection of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

78

14196

182

... More
E,T&C of HDGI flat of size 25x5 mm for earthing

320

15360

48

... More
Providing,testing&commissioning of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

64

201024

3141

... More
SCHEDULE 4

-

-

-

... More
Supply/Material

-

-

-

... More
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

12430

29061340

2338

... More
Supply of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

380

428260

1127

... More
Supply of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

6

3690000

615000

... More
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

22

12430000

565000

... More
Supply of 11KV RMU 4 Way,630A,with 3LBS +1 CB

1

710000

710000

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

71

627640

8840

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

27

798093

29559

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

22

148082

6731

... More
Supply of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

21

213192

10152

... More
Supply of Cable route Markers (for entire route length)

146

77088

528

... More
Supply of Warning Tapes (for entire route length) as per technical specification and drawing.

11.38

170700

15000

... More
Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV underground cables.including double run

1035.2

2246384

2170

... More
Laterite Masonary Works Rubble Packing with hard laterite stone under floors including watering rammaing and comsolidating etc in pipeline trench and other foundations complete. Single circuit 11kv cable trench(0.2*0.7*1.0)

556.73

1230930

2211

... More
Design, Supply of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

300

146400

488

... More
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

19884

2684340

135

... More
Supply of Bricks for cable separation

2750

26125

9.5

... More
Design, Supply of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

45

75645

1681

... More
Supply of HDGI flat of size 25x5 mm for earthing

300

34800

116

... More
Supply of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

60

397920

6632

... More
ERECTION, TESTING AND COMMISSIONING

-

-

-

... More
E,T&C of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

11930

4080060

342

... More
E,T&C of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

380

75620

199

... More
E,T&C of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

6

58320

9720

... More
E,T&C of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

22

213840

9720

... More
E,T&C of 11KV RMU 4 Way,630A,with 3LBS +1 CB

1

9720

9720

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

71

180908

2548

... More
E,T&C of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

27

100251

3713

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

22

55836

2538

... More
E,T&C of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

21

55608

2648

... More
E,T&C of Cable route Markers (for entire route length)

146

37376

256

... More
HDD Drawing of HT/LT UG Cables by trenchless technology by adopting HDD method.The work includes preparation of site ,boring as well as drawing of cables in normal/hard soil including soft ,watery and sandy soil with minimum 8inch bore size with HDPE pipe

500

1400000

2800

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kind of soil including Single run (1.1*.45*10830) + (1.1*.55*550) double run

5693.6

2664604

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge including double run

4658.4

559008

120

... More
Disposal of surplus excavated soil/material by mechanical transportation including loading and unloading,stacking/leveling as directed within a distance of 3000mts

1035.2

130248

125.82

... More
Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

300

23100

77

... More
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

19884

1193040

60

... More
Erection of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

45

8190

182

... More
E,T&C of HDGI flat of size 25x5 mm for earthing

300

14400

48

... More
Providing,testing&commissioning of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

60

188460

3141

... More
SCHEDULE 5

-

-

-

... More
Supply/Material

-

-

-

... More
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

1850

4325300

2338

... More
Supply of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

700

1116500

1595

... More
Supply of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

120

135240

1127

... More
Supply of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

1

615000

615000

... More
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

3

1695000

565000

... More
Supply of 11KV RMU 4 Way,630A,with 3LBS +1 CB

3

2130000

710000

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

21

185640

8840

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

4

118236

29559

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 185sq.mm

2

15746

7873

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 185sq.mm.

1

27079

27079

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

6

40386

6731

... More
Supply of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

6

60912

10152

... More
Supply of Cable route Markers (for entire route length)

20

10560

528

... More
Supply of Warning Tapes (for entire route length) as per technical specification and drawing.

1.6

24000

15000

... More
Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV underground cables.including double run

144

312480

2170

... More
Laterite Masonary Works Rubble Packing with hard laterite stone under floors including watering rammaing and comsolidating etc in pipeline trench and other foundations complete. Single circuit 11kv cable trench(0.2*0.7*1.0)

74.67

165095

2211

... More
Design, Supply of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

50

24400

488

... More
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

2667

360045

135

... More
Design, Supply of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

15

25215

1681

... More
Supply of HDGI flat of size 25x5 mm for earthing

80

9280

116

... More
Supply of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

16

106112

6632

... More
ERECTION, TESTING AND COMMISSIONING

-

-

-

... More
E,T&C of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

1600

547200

342

... More
E,T&C of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

700

184100

263

... More
E,T&C of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

120

23880

199

... More
E,T&C of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

1

9720

9720

... More
E,T&C of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB

3

29160

9720

... More
E,T&C of 11KV RMU 4 Way,630A,with 3LBS +1 CB

3

29160

9720

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm

21

53508

2548

... More
E,T&C of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.

4

14852

3713

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 185sq.mm

2

5096

2548

... More
E,T&C of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 185sq.mm.

1

3450

3450

... More
E,T&C of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm

6

15228

2538

... More
E,T&C of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm

6

15888

2648

... More
E,T&C of Cable route Markers (for entire route length)

20

5120

256

... More
HDD Drawing of HT/LT UG Cables by trenchless technology by adopting HDD method.The work includes preparation of site ,boring as well as drawing of cables in normal/hard soil including soft ,watery and sandy soil with minimum 8inch bore size with HDPE pipe

250

700000

2800

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kind of soil including Single run (1.1*.45*1600)

792

370656

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge including double run

648

77760

120

... More
Disposal of surplus excavated soil/material by mechanical transportation including loading and unloading,stacking/leveling as directed within a distance of 3000mts

144

18118

125.82

... More
Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

50

3850

77

... More
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

2667

160020

60

... More
Erection of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

15

2730

182

... More
E,T&C of HDGI flat of size 25x5 mm for earthing

80

3840

48

... More
Providing,testing&commissioning of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

16

50256

3141

... More
SCHEDULE 6

-

-

-

... More
Supply/Material

-

-

-

... More
Supply, storage, transporation to work site, laying, terminating, testing & commisioning of 11KV 3C x 300 Sq.mm size aluminium conductor screened XLPE galvanised flat strip armoured sheated PVC cable, type A2XFY confirming to IS

22396

52361848

2338

... More
Supply, storage, transporation to work site, laying, terminating, testing & commisioning of 11KV 3C x 95Sq.mm size aluminium conductor screened XLPE galvanised flat strip armoured sheated PVC cable, type A2XFY confirming to IS

490

552230

1127

... More
Supply of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

11

6765000

615000

... More
Supply of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards

23

12995000

565000

... More
Supply of straight through joint complete for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc

39

1152801

29559

... More
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc

74

654160

8840

... More
Supply of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc

7

81669

11667

... More
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x95sq.mm including sockets/lugs/connectors etc

24

161544

6731

... More
Supply of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm including sockets/lugs/connectors etc

22

223344

10152

... More
Supply and laying of fine river sand of approved quality for cushioning of HT underground cables laid by conventional Open Trenching Method. (0.2x 0.45 x 19386) (single run) & (0.2x 0.55 x 1250) (Double run)

1882.24

4084460

2170

... More
Supply of Bricks for Cable Separation for Double run cable (1250 mtr)

6250

59375

9.5

... More
Supply of RCC Hume Pipe 100mm Dia with required number of collars for road crossing

650

317200

488

... More
Supply of Class B HDGI Pipe 100mm dia for cable raiser

166

134626

811

... More
Supply of RCC Route Marker

259

136752

528

... More
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

22396

3023460

135

... More
Supply of HDGI flat of size 25x5 mm for earthing

730

84680

116

... More
Supply of H.D.G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling

75

204750

2730

... More
Laterite Masonary Works Rubble Packing with hard laterite stone under floors including watering rammaing and comsolidating etc in pipeline trench and other foundations complete. Single circuit 11kv cable trench(0.2*0.7*1.0)

2100

4643100

2211

... More
ERECTION, TESTING AND COMMISSIONING

-

-

-

... More
storage, transporation to work site, laying, terminating, testing & commisioning of 11KV 3C x 300 Sq.mm size aluminium conductor screened XLPE galvanised flat strip armoured sheated PVC cable, type A2XFY confirming to IS

22396

7659432

342

... More
storage, transporation to work site, laying, terminating, testing & commisioning of 11KV 3C x 95Sq.mm size aluminium conductor screened XLPE galvanised flat strip armoured sheated PVC cable, type A2XFY confirming to IS

490

97510

199

... More
E,T&C of 11KV,630 amps,outdoor SF6 Ring Main Unit with three Load Break Switches with Aux PT

11

106920

9720

... More
E,T&C of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards

23

223560

9720

... More
E,T&C of straight through joint complete for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc

39

144807

3713

... More
E,T&C of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc

74

188552

2548

... More
E,T&C of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc

7

19026

2718

... More
E,T&C of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x95sq.mm including sockets/lugs/connectors etc

24

60912

2538

... More
E,T&C of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm including sockets/lugs/connectors etc

22

58256

2648

... More
Excavation in any type of soil inclding hard laterite soil.(1.1x 0.45 x 19386) (single run) & (1.1x .55x 1250) (Double run)

10352.32

4844885

468

... More
Refilling of excavated soil in the foundations, trenches etc. with avialable excavated earth (0.9x 0.45 x 19386) (single run) & 0.9x 0.55 x 1250(Double run)

8470.08

1016409

120

... More
Disposal of surplus excavated soil/material by mechanical transportation including loading and unloading,stacking/leveling as directed within a distance of 3000mts 0.2x0.45x19386(single run)& 0.2x0.55x1250 (Double run)

1882.24

236823

125.82

... More
E,T&C of RCC Hume Pipe 100mm Dia with required number of collars for road crossing

650

50050

77

... More
E,T&C of Class B HDGI Pipe 100mm dia for cable raiser

166

15272

92

... More
E,T&C of RCC Route Marker

259

66304

256

... More
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

22396

1343760

60

... More
E,T&C of HDGI flat of size 25x5 mm for earthing

730

35040

48

... More
E,T&C of H.D.G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling

75

183300

2444

... More
HDD Drawing of HT/LT UG Cables by trenchless technology by adopting HDD method.The work includes preparation of site ,boring as well as drawing of cables in normal/hard soil including soft ,watery and sandy soil with minimum 8inch bore size with HDPE pipe

510

1428000

2800

... More
SCHEDULE 7

-

-

-

... More
Supply/Material

-

-

-

... More
33 KV material

-

-

-

... More
Supply, Storage, Transportation to works site, laying, termination testing and commissioning of 33KV 3core 400sq.mm size Aluminium Conductor screened XLPE insulated galvanised flat strip armoured shielded PVC Cable including jointing etc. type A2XFY confirming to IS 7089/part II

17000

61200000

3600

... More
Supply of 33KV, 630A. 25KA, 3Way outdoor load break switch comprising of 3 nos. 630A isolators

2

4956000

2478000

... More
Supply of GOAB Switch 36KV 800 Amps (double break)

2

289620

144810

... More
Supply of 33KV XLPE cable outdoor end termination kit for 3cx400sqmm cable

6

193920

32320

... More
Supply of 33KV XLPE cable indoor end termination kit for 3cx400sqmm cable

6

133968

22328

... More
Supply of XLPE straight through jointing kit for 33KV 400sq.mm cable

50

2862500

57250

... More
Sand for cushioning of HT Underground Cable (0.2*0.6*7600)

912

1979040

2170

... More
Supply of 33KV UG Cable 300 sq.mm and 400sq. mm by trenchless technology by adopting horizontal directional drilling (HDD methods). The work includes preparation of site, boring as well as drawing of cable in hard/laterite stone with minimum 9 inch bore size including supply and erection of HD PE pipe 200mm PN6 PE100 Thickness 8mm

1800

5958000

3310

... More
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

25333

3419955

135

... More
Laterite Masonary Works Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete for: b) Double Circuit 33KV Cable trench (0.2x0.9x1.00) i.e. 0.18 per RM (0.2x0.9x5000)

900

1989900

2211

... More
Supply of HDGI flat of size 25x5 mm for earthing

10

1160

116

... More
Supply of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

2

13264

6632

... More
Supply of H.D.G.I Pipe 150mm for riser of the cable

50

84050

1681

... More
Providing, laying and fixing with collars RCC pipes 250mm dia wherever there is road crossing, entrance of premises etc.

300

242100

807

... More
Supply of RCC cable route markers for indication of the cables.

85

44880

528

... More
Supply of Bricks for cable separation

38000

361000

9.5

... More
Supply of HDGI Structure Material

500

84500

169

... More
Supply of Warning Tape

7.6

114000

15000

... More
Amount towards ground rent for (5) years, Road cutting and road Reinstatement charges and GIDC processing Charging

1

277096

277096.3

... More
ERECTION, TESTING AND COMMISSIONING

-

-

-

... More
33 KV material

-

-

-

... More
Supply, Storage, Transportation to works site, laying, termination testing and commissioning of 33KV 3core 400sq.mm size Aluminium Conductor screened XLPE insulated galvanised flat strip armoured shielded PVC Cable including jointing etc. type A2XFY confirming to IS 7089/part II

15200

5639200

371

... More
E,T&C of 33KV, 630A. 25KA, 3Way outdoor load break switch comprising of 3 nos. 630A isolators

2

27000

13500

... More
E,T&C of GOAB Switch 36KV 800 Amps (double break)

2

19768

9884

... More
E,T&C of 33KV XLPE cable outdoor end termination kit for 3cx400sqmm cable

6

26346

4391

... More
E,T&C of 33KV XLPE cable indoor end termination kit for 3cx400sqmm cable

6

24846

4141

... More
E,T&C of XLPE straight through jointing kit for 33KV 400sq.mm cable

50

275000

5500

... More
Earth work excavation Double run in foundation trenches or drain including opening of roads, chamber, pavements and soiling, ramming, leveling of bottoms, making bottom free from stones including removing out the excavated soil/ material as directed. all kind of Soil cable(1.3*0.6*5600)

5376

2515968

468

... More
Earth work excavation Double run in foundation trenches or drain including opening of roads, chamber, pavements and soiling, ramming, leveling of bottoms, making bottom free from stones including removing out the excavated soil/ material as directed. Hard rock cable(1.3*0.6*2000)

1560

1190280

763

... More
Disposal of surplus excavated soil/material by mechanical transportation including loading and unloading,stacking/leveling as directed within a distance of 3000mts

912

114747

125.82

... More
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

25333

1519980

60

... More
Back filling of the available excavated earth (excluding rock) in trenches, plinth, sides, foundation etc. in layer work exceeding 0.2 mtr. Depth consolidating each deposited layer by ramming and watering (1.1*0.6*7600).

5016

601920

120

... More
E,T&C of HDGI flat of size 25x5 mm for earthing

10

480

48

... More
Providing,testing&commissioning of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification

2

6282

3141

... More
E,T&C of H.D.G.I Pipe 150mm for riser of the cable

50

9100

182

... More
Providing, laying and fixing with collars RCC pipes 250mm dia wherever there is road crossing, entrance of premises etc.

300

76200

254

... More
E,T&C of RCC cable route markers for indication of the cables.

85

21760

256

... More
E,T&C of HDGI Structure Material

500

23500

47

... More
SCHEDULE 8

-

-

-

... More
Dismantling of Line Material

-

-

-

... More
90 lb Rail pole

162

1705050

10525

... More
105lb Rail Pole

140

2239090

15993.5

... More
9 mtrs RCC Pole

362

797848

2204

... More
11 Mtrs Pole

19

81700

4300

... More
HDGI 33 KV V-shape 'X' arm

216

46332

214.5

... More
33 KV Pin insulator with GI pin

576

88704

154

... More
33 KV Disc insulator 70KN

1419

130548

92

... More
Metal parts for 33kv disc insulators

465

44407

95.5

... More
Guard 'X' arm of channel for 33KV

13

4140

318.5

... More
Cut point 'X' arm of channel for 33kv

25

6362

254.5

... More
G.O.A.B. Switch 33 KV 800 Amps d.b

4

19768

4942

... More
HDGI 11 KV V-shape 'X' arm

441

74529

169

... More
Cut point 'X' arm of channel for 11kv

346

85116

246

... More
Guard 'X' arm of channel for 11KV

390

106470

273

... More
HDGI Top fitting cross arm ISMC channel, 11KV

720

82080

114

... More
11 KV Pin insulator with GI pin

1743

132468

76

... More
11 KV Disc insulator 45 KN with M.P

1152

191232

166

... More
HDGI Structure material

4672.8

109810

23.5

... More
HDGI Nuts and Bolts

1158

17370

15

... More
G.O.A.B. Switch 11 KV 400 Amps

20

39890

1994.5

... More
ACSR Raccon Conductor for line

31.3

161727

5167

... More
ACSR Weasel Conductor for line, guarding and earthing

99.85

354966

3555

... More
SCHEDULE 9

-

-

-

... More
Civil work for RCC foundation for the RMU,s included for all the proposed feeder conversions

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :

-

-

-

... More
All kinds of soil

619.77

177254

286

... More
All types of Ordinary rock including all types of laterite rock, blasting prohibited

154.94

99006

639

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

134.72

297865

2211

... More
Providing & laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded granitic or basaltic stone aggrt. 40 mm. nominal size) excluding cost of centering, shuttering and finishing in:

-

-

-

... More
All works upto plinth level

67.35

417031

6192

... More
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size)

-

-

-

... More
All works upto plinth level

205.71

1476586

7178

... More
Centering & shuttering including Strutting, Propping & removal of forms for :

-

-

-

... More
Foundations, Footings, Bases for columns

138.79

56487

407

... More
Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like

1378.55

660325

479

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

366.94

89900

245

... More
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.

134672

14140560

105

... More
12mm cement plaster 1:4 (1 cement : 4 fine sand)

444.08

99029

223

... More
Transportation and carriage of material

-

-

-

... More
Earth up to 10km

398.81

48375

121.3



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.