Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 19,74,125Document Cost
₹ 1,500Tender Fee
₹ 6,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ED_14964_1Bid Award Id
ViewTender No
Tender No.114(2023-24)/CSCTender Authority
Electricity Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable
7485
11938575
1595
Supplying and filling in plinth under floors, trenches
including watering ramming consolidating, dressing, complete. Sand for cushioning of HT underground cables. ( 1R : 11535 x 0.2 x 0.4) ( 2R : 3850 x 0.2 x 0.6 )
1385
3005450
2170
Supply of RCC Pipe : 100 mm dia NP2 Pipe as per GSR 2020 (Roads) item nn 1910
100
48800
488
Supply of GI Pipe 150mm, class B for road crossing/bridge & cable riser
360
605160
1681
Supply of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed)
32058
4071366
127
Supply of Bricks class design 75 kg/cm2 (1st class wire cut)
35981
341819
9.5
Supply of 11 KV Straight Through joint 3 core 300 sqmm XLPE
32
945888
29559
Supply of 11 KV Straight Through joint 3 core 185 sqmm XLPE
15
406185
27079
Supply of 11 KV Termination kit Indoor 3 core 185 sqmm XLPE
11
86603
7873
Supply of 11 KV Termination kit Indoor 3 core 300 sqmm XLPE
36
318240
8840
Supply of 11 KV Termination kit outdoor 3 core 300 sqmm XLPE
5
58335
11667
Supply of RCC Cable route marker (400 x 900 x 100mm)
232
122496
528
Supply & Erection of Warning tape.
15
225000
15000
Ring Main Unit
-
-
-
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB : Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU.
14
7910000
565000
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS : Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxiliary PT as per specification shall be provided in RMU.
2
1088000
544000
Supply of 4 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 2CB : a. Extensible/Non Extensible two (2) Motor operated load break switches (LBSs) with Motor operated earthing switches in SF6 and 2 vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU.
4
3380000
845000
Civil Work for Ring Main Unit
-
-
-
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as
directed in :a) All kinds of soil
14
6552
468
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations.
10
55550
5555
Centering and shuttering including struttings, propping etc and removal of formwork .
70
39410
563
Supply and erection of 12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.
14
2058
147
11KV Cable for RMU & Jointing Kits
-
-
-
Supply of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.
340
383180
1127
Supply of 11 KV Termination kit Indoor 3 core 95 sqmm XLPE
17
114427
6731
Supply of 11 KV Termination kit Outdoor 3 core 95 sqmm XLPE
17
172584
10152
Supplying and filling in plinth under floors, trenches
including watering ramming consolidating, dressing, complete. Sand for cushioning of HT underground cables.
14
30380
2170
Supply of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.
283
35941
127
Supply of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete. (For RMU & Cable Earthing)
82
223860
2730
Supply of HDGI flat of size 25mm x 6mm for RMU & Cable earthing.
246
28536
116
Supply ofHDGI Structural Material (Such as cable supports,clamps, N&B Etc)
500
84500
169
Cost of Erection
-
-
-
11KV Cable Work
-
-
-
Laying, Testing & commissioning of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable in open trench method
10750
3676500
342
Laying, Testing & commissioningof HT/LT UG cables by trenchless technology by adopting horizontal directional drilling (HDD method). The work includes preparation of site, Boring as well as drawing of cable in Normal/hard soil including soft, watery and sandy soil with minimum 8" bore size, including Supply & Laying of HDPE pipe
5000
12415000
2483
Laying, Testing & commissioning of 11KV, 3 core 185 sq.mm A2XFY Aluminium Armoured XLPE Cable
7485
1968555
263
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as
directed in :a) All kinds of soil ( 1R : 11535 x 1.1 x 0.4) ( 2R : 3850 x 1.1 x 0.6 )
7616
3564288
468
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge ( 1R : 11535 x 0.9 x 0.4) ( 2R : 3850 x 0.9 x 0.6 )
6232
747840
120
Laying of RCC Pipe : 100 mm dia NP2 Pipe as per GSR 2020 (Roads) item nn 1910
100
7700
77
Laying of GI Pipe 150mm, class B for road crossing/bridge & cable riser
360
65520
182
Erection of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed)
32058
2692872
84
Erection, Testing & Commissioning of 11 KV Straight Through joint 3 core 300 sqmm XLPE
32
118816
3713
Erection, Testing & Commissioning of 11 KV Straight Through joint 3 core 185 sqmm XLPE
15
51750
3450
Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 185 sqmm XLPE
11
28028
2548
Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 300 sqmm XLPE
36
91728
2548
Erection, Testing & Commissioning of of 11 KV Termination kit outdoor 3 core 300 sqmm XLPE
5
13590
2718
Erection of RCC Cable route marker (400 x 900 x 100mm)
232
59392
256
Ring Main Unit
-
-
-
Erection, Testing & Commissioning of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB : Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU.
14
136080
9720
Erection, Testing & Commissioning of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS : Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxiliary PT as per specification shall be provided in RMU.
2
19440
9720
Erection, Testing & Commissioning of 4 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 2CB : a. Extensible/Non Extensible two (2) Motor operated load break switches (LBSs) with Motor operated earthing switches in SF6 and 2 vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU.
4
38880
9720
11KV Cable for RMU & Jointing Kits
-
-
-
Erection, Testing & Commissioning of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.
340
67660
199
Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 95 sqmm XLPE
17
43146
2538
Erection, Testing & Commissioning of of 11 KV Termination kit Outdoor 3 core 95 sqmm XLPE
17
45016
2648
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as
directed in :a) All kinds of soil b) All types of Ordinary rock including all types of laterite rock, blasting prohibited
75
35100
468
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge
62
7440
120
Erection of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.
283
23772
84
Erection, Testing & Commissioning of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete. (For RMU & Cable Earthing)
82
200408
2444
Erection of HDGI flat of size 25mm x 6mm for RMU & Cable earthing.
246
11808
48
Erection of HDGI Structural Material (Such as cable supports,clamps, N&B Etc)
500
23500
47
Evaluation Notes How It Works ?