Scanning Tenders
Scanning Tenders
Province Of South Cotabato Tender
Civil And Construction...+1Construction Material
Philippines
Details: Description Standard Form Number: Sf-good-60 Revised On: May 24, 2004 Standard Form Title: Request For Quotation Republic Of The Philippines Provincial Government Of South Cotabato Bids And Awards Committee Capitol Compound, Alunan Avenue, City Of Koronadal Tel. No. (083) 228-9951 1. All Entries Must Be Handwritten (legible)/ Typewritten 2. Delivery Period Within 30 Calendar Days Upon Receipt Of The Notice To Proceed Note: Date: Svp 24 - 0433 April 02, 2024 Quotation No. Please Quote Your Lowest Price On The Items Listed Below, Subject To The General Conditions Below, Stating The Shortest Time Of Delivery And Submit Your Quotation Duly Signed By Your Representative Not Later Than April 16, 2024 12:00 Noon Provincial Legal Officer Bac Chairman (sgd.) Atty. Marnito B. Cosep 3. Warranty Shall Be For Period Of Three (3) Months For Supplies And Materials, One (1) Year For Equipments, From Date Of Acceptance By The Procuring Entity 4. Price Validity Shall Be For A Period Of 120 Days 5. Interested Suppliers Are Required To Submit Their Eligibility Documents Such As Valid And Current Mayor’s Permit/business Permit, Philgeps Registration Number ________, And Income/business Tax Return (for Abcs Above 500k) During The Submission Of Price Quotation. 6. Bidders Shall Submit Original Brochures Showing Certifications Of The Product Being Offered (if Applicable) 7. Omnibus Sworn Statement Must Be Submitted During Submission Of Offer/s Or Before Issuance Of Notice Of Award.(for Abcs Above P50k) Note: Suppliers With Updated Eligibility Documents On File At The Bids And Awards Committee, May No Longer Require Its Re-submission. Quotation By Lot Item No. Item & Description Qty. Unit Of Total Cost Issue Unit Cost 1 Job Order , Labor And Materials For The Repair Of Toyota Hilux 2.8l 4x4 With Lot Temporary Plate Number 1312-441869 And Property Number 310089 Mechanical Works (labor): - Adjustment Of Hand Brake - Draining And Refilling Of Deferential And Transmission Oil. - Greasing Of Cross Joint Propeller - Pull Out And Install 2 Pcs. Shock Absorber Lh/rh - Pull Out And Install Suspension Arm Upper To Replace 2 Pcs. Ball Joint Lh/rh - Pull Out And Replace 2 Pcs. Rack End - Pull Out Axle Assy. And Replace 2 Pcs. Velocity Boots Lh/rh - Pull Out And Replace 1 Set Wiper Blade Machining Works (labor): - Press In And Out Of 2 Pcs. Ball Joint Upper - Press In And Out 2 Pcs. Shock Bushing Electrical Works (labor): - Pull Out And Replace 1 Pc. Head Light Bulb Rh Side Painting Works (labor/materials): - Bopping Of Whole Body - Bopping Of 2 Pcs. Head Light - Apply Wax And Rubbing Compound Upholstery (labor/materials): - Supply 1 Set Floor Mats (black) 1 Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110009550; Pr.no.24 - 0550 Page 1 Of 5 Standard Form Number: Sf-good-60 Revised On: May 24, 2004 Standard Form Title: Request For Quotation Republic Of The Philippines Provincial Government Of South Cotabato Bids And Awards Committee Capitol Compound, Alunan Avenue, City Of Koronadal Tel. No. (083) 228-9951 1. All Entries Must Be Handwritten (legible)/ Typewritten 2. Delivery Period Within 30 Calendar Days Upon Receipt Of The Notice To Proceed Note: Date: Svp 24 - 0433 April 02, 2024 Quotation No. Please Quote Your Lowest Price On The Items Listed Below, Subject To The General Conditions Below, Stating The Shortest Time Of Delivery And Submit Your Quotation Duly Signed By Your Representative Not Later Than April 16, 2024 12:00 Noon Provincial Legal Officer Bac Chairman (sgd.) Atty. Marnito B. Cosep 3. Warranty Shall Be For Period Of Three (3) Months For Supplies And Materials, One (1) Year For Equipments, From Date Of Acceptance By The Procuring Entity 4. Price Validity Shall Be For A Period Of 120 Days 5. Interested Suppliers Are Required To Submit Their Eligibility Documents Such As Valid And Current Mayor’s Permit/business Permit, Philgeps Registration Number ________, And Income/business Tax Return (for Abcs Above 500k) During The Submission Of Price Quotation. 6. Bidders Shall Submit Original Brochures Showing Certifications Of The Product Being Offered (if Applicable) 7. Omnibus Sworn Statement Must Be Submitted During Submission Of Offer/s Or Before Issuance Of Notice Of Award.(for Abcs Above P50k) Note: Suppliers With Updated Eligibility Documents On File At The Bids And Awards Committee, May No Longer Require Its Re-submission. Quotation By Lot Item No. Item & Description Qty. Unit Of Total Cost Issue Unit Cost Complete Wheel Alignment And Wheel Balancing Of The Unit (labor/materials): Tinting Works (labor/materials): - Tinting Of All Glass Using Magic Tint. (except Windshield Assy.) Materials Needed: 1 Pc. Headlight Bulb Rh 2 Pcs. Shock Absorber Bushing Lh/rh Orig. 1 Set Wiper Blade (banana Type) 2 Pcs. Velocity Boots Lh/rh Orig. 2 Pcs. Ball Joint Upper Orig. 2 Pcs. Rack End Orig. 1 Can Grease 5 Pcs. Tire Clawer Deestone 265/70r17 Log Tire 1 Pc. Tire Valve Rubber 1 Gal. Transmission Oil 1 Gal. Deferential Oil 1 Pc. Cabin Filter Orig. 2 Job Order , Labor And Materials For The Repair Of Kia K2700 4x4 Dc With Lot Temporary Plate Number 1201-209899 And Property Number 010 Mechanical Work (labor): - Top Overhauling Of Engine, Pull Out And Replace 1 Pc. Cylinder Head Gasket, 1 Set Valve, 1 Set Valve Guide, 1 Set Valve Seat, 1 Set Valve Seal, 1 Pc. Valve Cover Gasket, 1 Pc. Valve Intake Manifold Gasket And 1 Pc. Valve Exhaust Manifold Gasket. 1 Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110009550; Pr.no.24 - 0550 Page 2 Of 5 Standard Form Number: Sf-good-60 Revised On: May 24, 2004 Standard Form Title: Request For Quotation Republic Of The Philippines Provincial Government Of South Cotabato Bids And Awards Committee Capitol Compound, Alunan Avenue, City Of Koronadal Tel. No. (083) 228-9951 1. All Entries Must Be Handwritten (legible)/ Typewritten 2. Delivery Period Within 30 Calendar Days Upon Receipt Of The Notice To Proceed Note: Date: Svp 24 - 0433 April 02, 2024 Quotation No. Please Quote Your Lowest Price On The Items Listed Below, Subject To The General Conditions Below, Stating The Shortest Time Of Delivery And Submit Your Quotation Duly Signed By Your Representative Not Later Than April 16, 2024 12:00 Noon Provincial Legal Officer Bac Chairman (sgd.) Atty. Marnito B. Cosep 3. Warranty Shall Be For Period Of Three (3) Months For Supplies And Materials, One (1) Year For Equipments, From Date Of Acceptance By The Procuring Entity 4. Price Validity Shall Be For A Period Of 120 Days 5. Interested Suppliers Are Required To Submit Their Eligibility Documents Such As Valid And Current Mayor’s Permit/business Permit, Philgeps Registration Number ________, And Income/business Tax Return (for Abcs Above 500k) During The Submission Of Price Quotation. 6. Bidders Shall Submit Original Brochures Showing Certifications Of The Product Being Offered (if Applicable) 7. Omnibus Sworn Statement Must Be Submitted During Submission Of Offer/s Or Before Issuance Of Notice Of Award.(for Abcs Above P50k) Note: Suppliers With Updated Eligibility Documents On File At The Bids And Awards Committee, May No Longer Require Its Re-submission. Quotation By Lot Item No. Item & Description Qty. Unit Of Total Cost Issue Unit Cost - Overhauling Of Radiator Assy. - Change Oil Of Transmission - Change Oil Of Differential - Change Oil Of Engine Machining Works (labor): - Resurface Of Head - Install Valve, Valve Guide, Valve Seal And Valve Seat - Setting Of Head Body Works (labor/materials): - Pull Out And Install Of Ceiling. Repair Rotten Portion Of Roof Including Painting. - Installation Of New Door Pads Assy. With Holder And Opener Inner. - Replace Back Door Lock Assy. - Fabrication Of Back Door Lock Housing Includes Painting. Upholstery (labor/materials): - Replace 1 Set Seat Cover Leatherette - Installation Of 1 Set Floor Mats Front And Rear Tinting Works (labor/materials): - Tinting Of All Glass Using Lumina Black Tint. (front/rear) Except Division. Glass Works (labor): - Pull Out And Replace 1 Pc. Windshield Assy. - Pull Out And Replace 2 Pcs. Window Glass Rear With 2 Pcs. Glass Rubber. Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110009550; Pr.no.24 - 0550 Page 3 Of 5 Standard Form Number: Sf-good-60 Revised On: May 24, 2004 Standard Form Title: Request For Quotation Republic Of The Philippines Provincial Government Of South Cotabato Bids And Awards Committee Capitol Compound, Alunan Avenue, City Of Koronadal Tel. No. (083) 228-9951 1. All Entries Must Be Handwritten (legible)/ Typewritten 2. Delivery Period Within 30 Calendar Days Upon Receipt Of The Notice To Proceed Note: Date: Svp 24 - 0433 April 02, 2024 Quotation No. Please Quote Your Lowest Price On The Items Listed Below, Subject To The General Conditions Below, Stating The Shortest Time Of Delivery And Submit Your Quotation Duly Signed By Your Representative Not Later Than April 16, 2024 12:00 Noon Provincial Legal Officer Bac Chairman (sgd.) Atty. Marnito B. Cosep 3. Warranty Shall Be For Period Of Three (3) Months For Supplies And Materials, One (1) Year For Equipments, From Date Of Acceptance By The Procuring Entity 4. Price Validity Shall Be For A Period Of 120 Days 5. Interested Suppliers Are Required To Submit Their Eligibility Documents Such As Valid And Current Mayor’s Permit/business Permit, Philgeps Registration Number ________, And Income/business Tax Return (for Abcs Above 500k) During The Submission Of Price Quotation. 6. Bidders Shall Submit Original Brochures Showing Certifications Of The Product Being Offered (if Applicable) 7. Omnibus Sworn Statement Must Be Submitted During Submission Of Offer/s Or Before Issuance Of Notice Of Award.(for Abcs Above P50k) Note: Suppliers With Updated Eligibility Documents On File At The Bids And Awards Committee, May No Longer Require Its Re-submission. Quotation By Lot Item No. Item & Description Qty. Unit Of Total Cost Issue Unit Cost Materials Needed: 1 Pc. Valve Cover Gasket Orig. 1 Set Valve Ext./intake Orig. 1 Set Valve Seal Orig. 1 Pc. Cylinder Head Gasket Orig. 1 Set Valve Guide Orig. 1 Set Valve Seat Oversize 1 Gal. Transmission Oil 1 Gal. Differential Oil 1 Set Back Door Lock Assy. 1 Pc. Door Pads Rear Lh Orig. 1 Pc. Door Pad Handle Rear Lh Orig. 1 Pc. Door Pad Handle Cover Rear Lh Orig. 1 Pc. Battery Mf Motolite Gold 1 Pc. Windshield Laminated 1 Pc. Sikaflex 1 Pc. Exhaust Manifold Gasket Orig. 1 Set Intake Manifold Gasket Orig. 7 Qrts. Synthetic Oil 1 Pc. Oil Filter Orig. 1 Pc. Fuel Filter Orig. 3 Job Order , Labor And Materials For The Repair Of Toyota Hiace Commuter With Lot Temporary Plate Number 1201-764514 And Property Number 310088 Electrical Works (labor): - Checked And Evaluate Electrical Components Of The Unit. - Scanning And Diagnosed Main Problem Of Electrical System. 1 Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110009550; Pr.no.24 - 0550 Page 4 Of 5 Standard Form Number: Sf-good-60 Revised On: May 24, 2004 Standard Form Title: Request For Quotation Republic Of The Philippines Provincial Government Of South Cotabato Bids And Awards Committee Capitol Compound, Alunan Avenue, City Of Koronadal Tel. No. (083) 228-9951 1. All Entries Must Be Handwritten (legible)/ Typewritten 2. Delivery Period Within 30 Calendar Days Upon Receipt Of The Notice To Proceed Note: Date: Svp 24 - 0433 April 02, 2024 Quotation No. Please Quote Your Lowest Price On The Items Listed Below, Subject To The General Conditions Below, Stating The Shortest Time Of Delivery And Submit Your Quotation Duly Signed By Your Representative Not Later Than April 16, 2024 12:00 Noon Provincial Legal Officer Bac Chairman (sgd.) Atty. Marnito B. Cosep 3. Warranty Shall Be For Period Of Three (3) Months For Supplies And Materials, One (1) Year For Equipments, From Date Of Acceptance By The Procuring Entity 4. Price Validity Shall Be For A Period Of 120 Days 5. Interested Suppliers Are Required To Submit Their Eligibility Documents Such As Valid And Current Mayor’s Permit/business Permit, Philgeps Registration Number ________, And Income/business Tax Return (for Abcs Above 500k) During The Submission Of Price Quotation. 6. Bidders Shall Submit Original Brochures Showing Certifications Of The Product Being Offered (if Applicable) 7. Omnibus Sworn Statement Must Be Submitted During Submission Of Offer/s Or Before Issuance Of Notice Of Award.(for Abcs Above P50k) Note: Suppliers With Updated Eligibility Documents On File At The Bids And Awards Committee, May No Longer Require Its Re-submission. Quotation By Lot Item No. Item & Description Qty. Unit Of Total Cost Issue Unit Cost - Pull Out And Replace Damage Electrical Parts Of The Unit. - Replace 1 Pc. R/r Power Window Switch (lhs) - Replace 1 Pc. Master Switch Assy. Multiplex Network Installation Of 1 Set Rain Visor (labor/materials): Installation Of 1 Set Floor Mats Front And Rear (special Cut) (labor/materials): Installation Of 1 Set Head Light Accessories And 1 Set Tail Light Accessories (chrome Type) (labor/materials): 4 Job Order , Labor And Materials For The Repair Of Toyota Hilux 2.4l 4x4 With Lot Temporary Plate Number S1g-812 And Property Number Cal046 Mechanical Works (labor/materials): - Installation Of 1 Pc. Main Bearing Original Materials Needed: 1 Pc. Main Bearing Original 1 Total Abc: P 486,634.04 X-x-x Nothing Follows X-x-x Notes: For Repairs And Maintenance Of Four (4) Units' Vehicle Assigned At Pdrrmo. Total Amount Of Bid: Source Of Fund: 2024 5% Pdrrmf - Dpp-1.4.5 - 5-02-13-050 - Mooe-24-03-12980 Approved Budget: P 486,634.04 Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110009550; Pr.no.24 - 0550 Page 5 Of 5
Closing Date16 Apr 2024
Tender AmountPHP 486.6 K (USD 8.6 K)
Department Of Education Division Of Palawan Tender
Others...+2Electronics Equipment, Construction Material
Philippines
Details: Description Request For Quotation Date: September 18, 2024 Quotation No: 2024-09-086 To All Eligible Suppliers: The Schools Division Of Palawan, Through Its Bids And Awards Committee (bac), Intends To Procure A Supply And Delivery Of Audio-video Conferencing Equipment And Mobile Information And Communication Technology Solutions With An Approved Budget For The Contract Six Hundred Sixteen Thousand Five Hundred Forty-five Pesos Only (php 616,545.00) Through Section 52.1(b) (shopping) Of 2016 Revised Implementing Rules And Regulations Of Republic Act No. 9184. Please Quote Your Lowest Price Inclusive Of Vat On The Item/s Listed Below, Subject To The Terms And Conditions Of The Rfq, And Submit Your Quotation Duly Signed By Your Representative Not Later Than 09:00 Am Of October 7, 2024. At 3rd Floor Bac Office, Deped Building, Sdo Palawan C/o Rafael G. Manalo, Phd, Bac Chairperson, Gov. Salvador P. Socrates Gov’t Center, Bancao-bancao, Puerto Princesa City. For More Information, Please Contact The Bac At (048) 433-6392. The Prospective Supplier Shall Be Responsible For Verifying The Quoted Items. (sgd) Rafael G. Manalo, Phd Assistant Schools Division Superintendent Chairperson, Bids And Awards Committee I. Project: Supply And Delivery Of Audio-video Conferencing Equipment And Mobile Information And Communication Technology Solutions No. Items And Description Qty. Unit Statement Of Compliance (state “comply Or Not Comply” Unit Price Total Price Supply And Delivery Of Audio-video Conferencing Equipment And Mobile Information And Communication Technology Solutions. Active Speaker Minimum Specifications: Power Output: 2500w Peak (1600w Lf + 900w Hf),1250w Continuous Rms (800w Lf + 450w Hf) Drivers: 12-inch Low-frequency Driver With A 2.5-inch High-temperature Voice Coil, 1-inch Exit Ceramic High-frequency Driver With A 1.4-inch Coil Bluetooth: Audio Streaming And True Wireless Stereo Speaker Linking Dsp: Onboard Dsp With 4-speaker Use Modes, Including Custom Eq Via The Alto App Mixer: Integrated 3-channel Mixer With Dual Xlr 1/4- Inch Combo Inputs, Mic/line Switches, And Independent Level Controls Outputs: Xlr Mix Output Frequency Response: 53 Hz To Khz Dispersion: 90° X 60° Design: Lightweight Enclosure, Pole-mountable, Wedge Monitor, Or Flown-application With Integral M10 Suspension Points Cooling: Fanless Cooling Design For Quieter Operation And Greater Reliability Control: Free Alto App For Remote Configuration And Control (ios/android) Dimentions: Approximately 13.8 X13.92 X 23.88 Inches 2 Units Tripod Speaker Stand Minimum Specifications: Product Type: Speaker Stands Tubing Material: Aluminium Tubing Colour: Black Tubing Surpace:n Powdered Coated Minimum Height: 1060 Mm Maximum Height: 1950 Mm Transport Length: 1950 Mm Height Adjustment: Clamp With Safety Pin Material Of Height Adjustment: Steel Base Type: Leg Joint Base Material: Die-cast Aliminium Tubing Diameter: 35 Mm Maximum Load: 50 Kg Interchangeable Rings: 5 X 30 Mm Black Ring Pack Included: Yes Weight: 2.2 Kg 2 Units 10-channel Analog Audio Mixer Usb Audio Interface Minimum Specifications: Preamps: Onyx Preamps With 60 Db Of Gain Effects Engine: Gigfx+ Effects Engine Usb Recording: With Its 24-bit / 192 Khz 2x4 Usb Audio Interface Bluetooth Connectivity: Bidirectional Bluetooth With Mix-minus Functionality Eq And Compression: Each Channel Has A 3-band Eq, And Channels 1 And 2 Feature One-knob Compression For Dynamic Control. Other Features: Hi-z Switch For Instruments, A 100 Hz Low-cut Filter,48v Phantom Power For Microphones Channel Inputs: Mic/line Inputs (channels 1-4): Xlr/trs Combo Jacks For Connecting Microphones Or Line Level Sources. Channels 1 And 2 Feature One-knob Compression For Dynamic Control. Hi-z Switch On Channel 2 For Instruments (e.g., Guitars) Stereo Lines Inputs (channels 5-10): Trs Jacks For Connecting Stereo Devices (e.g., Keyboards, Media Players). Channels 7/8 And 9/10 Can Be Switched To Mono. Channel Outputs: Main Outputs: Balanced Xlr Outputs For Connecting To Speakers Or An Audio Interface. Aux Sends: Two Aux Sends (pre-fader) Headphone Output: ¼ -inch Trs Headphone Output For Monitoring. Usb Output: Usb Connection For Recording Directly To Your Computer. 1 Unit Dual Uhf Wireless Microphone 200 Selectable Frequencies Auto Frequency Search Function Easy Synchronization And Operation Receiver Display For Battery Status Two Battery Charger Slots On The Receiver Lcd Display On Both The Transmitter And Receiver 1u Rack Space Mountable Dual Antenna Receiving System Powered By A 3.7v 1100mah Li-ion Battery Inclusions: Dual-channel Receiver Unit, Two Handled Wireless Microphones, Power Adapter For The Receiver 1 Unit Wireless Conference System Main Unit Minimum Specifications: Bluetooth, Built-in 16 Channel Wifi Frequences 50-meters Max Distance, Xlr & Pl (frequency Range 640-700mhz) Tcm-1000v Wireless Conference System Main Unit Built-in 16 Channel Wifi Frequencies Record & Play Through Usb And With Bluetooth Function 5 Groups Of Channels, Each Channel Has 130 Frequencies Fifo Function, Only 4 Units Can Use At The Same Time Wireless Capabilities Support An Infinite Number Of Units Built-in Advanced Encryption Communication Algorithm, Completely Eliminate Communication Errors And False Action. Balance Xlr & Unbalance Pl Output Automatic Shutdown. Host Standby For More Than 30 Minutes. Workable Distance Up To 50 Meters, Depend On Environment. Main Unit Can Be Rack Mounted. 1 Unit Delegate Unit, Wireless Microphone Unit Minimum Specifications: 1000vd Frequency Range 640-700mhz Mic On/off Buttons Unidirectional Consider Mic Red Light Indicate Mic Is On 12 Units Chairman Unit, Wireless Microphone Unit Minimum Specifications: Frequency Range 640-700mhz Tcm 1000vc Priority Buttons Mic On/off Buttons Undirectional Condenser Mic Red Light Indicate Mic Is On Chairman Units Can Also Use As Delegate Unit Can Override/mute All The Active Delegate Units 1 Unit Xlr 3 Pole Female To Xlr 3 Pole Male Minimum Specifications: 15-meter Premade Cable 3 Units 12u 19” Rack Flight Case Minimum Specifications: Type: Rack Tour/flight Case 1 Design: Constructed Using 9mm Plywood With Removable Front, Top And Rear Lids 1 Rack Space: 12u Equipment Space1 Mixer Rails: 10u Ratcheting1 Panels: Tough 3/8” Plywood And Abs Laminate1 Castors: 4” Swivel Casters Including Two Locking Style1 Latches: Recessed Butterfly Latches And Padded Flip Handles1 Corners: Large Stell Ball Corners1 Rack Depth: 18.25” Equipment Rack Depth1 Rack Rails: #10 X 32 Rack Rails Both Front And Back1 Bag Of Cage Nuts Supplied 1 Unit 5ghz Full Hd 1080p Wireless Hdmi Transmitter And Receiver Transmitter: Ports: 1xhdmi, 1xusb-c Resolution: 1080p@60hz Frequency Range: 2400-2483.5mhz/5150-5250mhz/5475-5850mhz Audio Sampling Rate: Up To 24bit 48 Khz Receiver: Ports: 1xhdmi, 1xvga, 1xusb-c (with Power), 1x3.5mm Audio Transmission Distance: 50 Meters (164 Feet) Without Blocking Usb Cable (type A To C): Included For Power 1 Unit Power Distribution Unit Minimum Specifications: 8-gang, Rack Mountable 1 Unit 4k Ai-powered Ptz Webcam Minimum Specifications: Camera: Max Video Resolution:4k@30fps, 1080p@60fps (mjpeg, H264) Supported Resolutions: 3840x2160,1920x1080,1280x720, 640x360 Zoom: 4x Focus Type: Auto/manual Hdr: Supported Field Of View (d):86º Built-in Dual Omni-directional Microphones With Noise Reduction 2-axis Gimbal: Controllable Range: Pan ±150º, Tilt ±45º Structurally Possible Range: Pan ±160º, Tilt ±90º Max Control Speed: 120º/s Connectivity: Usb-c Connection 1 Unit 100 Va Rackmountable On-line Ups Minimum Specifications: Ratings: 1000va/900w Battery: 2 X 12v/ 9ah Interface: 4x Universal Socket Form Factor: Tower Size: 440 X 468 X 88mm Weight: 12.26kg Technology: High-frequency Online Double Conversation, Dsp Digital Control Power Factor Correction: Active, Up To 0.99 Protection: Effective Software And Hardware Protection Battery: Hot-swappable, Quick And Stable Charging, 90% Capacity Restores In 3h Start: Settable Delayed Start When Power Is Restored Design: Tower / Rack Convertible Power Factor: High, Stronger Carrying Capacity Charger: Powerful Battery Charger Frequency Conversion: Yes Eco Mode: Yes Noise Level: Low Communication Ports: Multiple 1 Unit Mobile Information And Communication Technology Solutions Np-f970 Rechargeable Preplacement Battery (2-pack) 7.2v 7800mah With 5v 9v Usb Type C Dual Battery Charger Kit Minimum Specifications: Battery Type: Lithium-ion Battery Battery Parameter:7800mah 7.2v 56.16wh Battery Charging Limited Voltage: 8.4 V Charger Input: Micro Usb: 5v=2.4a, Usb-c: 5v=2.4a Micro Usb: 9v=2a, Usb-c: 9v=2a Charger Output: 5v Input: 8.4v=1000ma (single), 8.4v=700ma (dual) 9v Input: 8.4v=1500ma (single), 8.4v=1000ma (dual) Operating Environment Temperature: 0ºc˜40ºc Package Inclusions: 2 X Np-f970 Battery, 2 X Battery Protective Cover 1 X Dual Battery Charger ,1 X 0.6m Usb-a To Usb-c Cable, 1 X User Manual 4 Sets 4k 60hz Micro 2.0 Hdmi Male To Hdmi 2.0 Male Gold-plated Video Cable With 3d Vision Support (1 Meter) 12 Units Pro Standard Wireless Video Transmitter And Receiver Set With Hdmi Input And Hdmi Loop-out Minimum Specifications: Wireless Transmitter And Receiver Set Transmit Uhd 4k30 Video Up To 1300ft Hdmi Input, Output, And Hdmi Loop Output 2.4 And 5 Ghz Frequency Bands Supports Uvc Plug-and-play For Streaming 650ft Transmission In Broadcast Mode Smart Channel Scanning, Bright Lcd Low 60 Ms Latency, 12 Mb/s Bit Rate Dc, L-series, And Usb-c Power Supply Options 4 Sets Wireless Portable Document Scanner Minimum Specifications: Type: Wireless Portable Document Scanner Resolution: Optical Resolution Of 600 Dpi Scan Speed: Color Scan Speed Of 15ppm At 300 Dpi, Single Page Scan Speed Of 4 Seconds Maximum Scan Area: 8.5 X 72 Inches Connectivity: Usb 2.0 And Wi-fi Sensor Type: Cis Light Source: Rgb Led Automatic Feeding Mode: Yes Accounting Management Tools: Yes Ocr: Includes Nuance Ocr To Create Searchable Pdfs And Editable Word And Excel Files Special Features: Scans Id Cards And Receipts2, Automatically Detects Connectivity Size: 2.7 X 1.6 X 1.8 Inches 3 Units Delivery Period- Xxxxxxxxxxxxxxxxxxxxxxxxxx Approved Budget For The Contract (abc) Php. 616,545.00 Delivery Period: 5 Days Total: This Is To Submit Our Price Quotations As Included Above, Subject To The Terms And Conditions Of The Rfq. Supplier’s Company Name: Tin: Address: Telephone: Cp No.: E-mail: Supplier’s Authorized Representative Signature Over Printed Name: Date: Terms And Conditions Submission Of Requirements Sealed Quotations And Other Requirements Below Shall Be Submitted To The Bids And Awards Committee (bac) Secretariat At 3rd Floor, Deped Building, Schools Division Office Of Palawan, Gov. Salvador P. Socrates Gov’t Center, Bancao-bancao, Puerto Princesa City. Interested Supplier Shall Submit The Following Requirements: Duly Signed Request For Quotation. Prices Shall Be Quoted In Philippine Pesos. Statement Of Compliance Must Be Accomplished By The Supplier. Documentary Requirements Of The Following: Valid Mayor’s Permit Philgeps Registration Bidder’s Failure To Submit Such Documents Upon Opening Shall Be Grounds For Disqualification. Award The Supplier Who Submitted The Lowest Calculated And Responsive Quotation Shall Be Awarded The Purchase Order/contract After Evaluation By The Bac. Delivery Of Services Delivery Of Services Shall Be Made On The Schedule Date Upon Receipt Of Purchase Order/contract. Upon Delivery Of The Services, The Supplier Shall Notify The Purchaser And Present The Following Document/s To The Purchaser: Original And Copy Of The Supplier’s Statement Of Account. Evaluation Of Quotations Quotations Shall Be Compared And Evaluated Based On The Following Criteria: Completeness Of Submission. Compliance With Technical Specifications; And Price Instructions The Supplier Shall Be Responsible For All The Services To Be Rendered And Should Be In Accordance With The Schedule And Specifications Stipulated In The Contract/purchase Order. Failure Of The Supplier To Comply With This Provision Shall Be Grounds For Cancellation Of The Contract/purchase Order Issued To The Supplier. Supplier Shall Pick Up The Purchase Order/contract Issued In Its Favor Within Three (3) Calendar Days From Receipt Of Notice To The Effect. A Telephone Call Or Fax Transmission Shall Constitute An Official Notice To The Supplier. Thereafter, If The Purchases Order Remains Unclaimed, The Purchase Order Shall Be Canceled. To Avoid Delay In The Delivery Of The Requesting Agency’s Requirements, All Defaulting Supplier Shall Be Precluded From Proposing Or Submitting Substitute Quotation (s) Or Item (s). A Supplier Who Accepted A Purchase Order/contract But Failed To Deliver The Required Goods/services Within The Time Called For In The Purchase Order/contract Shall Be Disqualified From Participating In Deped Or Any Of Deped Unit’s Future Procurement Activities. This Is Without Prejudice To The Imposition Of Other Sanctions Prescribed Under R.a 9184 And Its Irr-a Against The Supplier. The Supplier Shall Pay All Duties, Excise, And Other Taxes And Revenue Charges. All Transactions Are Subject To Withholding Of Credible Value-added Tax And/or Expanded Value – Added Tax Per Revenue Regulation(s) Of The Bureau Of Internal Revenue. Payment One Hundred Percent (100%) Of The Contract Price Less Government Tax Shall Be Paid To The Supplier After Completion/compliance Of The Services Delivered. Payment Shall Be In The Form Of A Check And Addressed To The Supplier’s Name Firm. After Carefully Reading Your Request For Quotation And Its Terms And Conditions, I/we Quote You On The Item/s At The Price Noted In The Rfq. The Quotation Shall Be Binding Upon Us For Thirty (30) Calendar Days Reckoned From The Last Day Of Submission Indicated In The Submission Requirements. We Shall Accept The Corresponding Award On Purchase Order At Any Time Before The Expiration Of This Period
Closing Date7 Oct 2024
Tender AmountPHP 616.5 K (USD 10.9 K)
Province Of South Cotabato Tender
Electronics Equipment...+2Machinery and Tools, Electrical and Electronics
Philippines
Details: Description Standard Form Number: Sf-good-60 Revised On: May 24, 2004 Standard Form Title: Request For Quotation Republic Of The Philippines Provincial Government Of South Cotabato Bids And Awards Committee Capitol Compound, Alunan Avenue, City Of Koronadal Tel. No. (083) 228-9951 1. All Entries Must Be Handwritten (legible)/ Typewritten 2. Delivery Period Within 10 Calendar Days Upon Receipt Of The Notice To Proceed Note: Date: Svp 24 - 1396 October 30, 2024 Quotation No. Please Quote Your Lowest Price On The Items Listed Below, Subject To The General Conditions Below, Stating The Shortest Time Of Delivery And Submit Your Quotation Duly Signed By Your Representative Not Later Than November 12, 2024 12:00 Noon Provincial Legal Officer Bac Chairman (sgd.) Atty. Marnito B. Cosep 3. Warranty Shall Be For Period Of Three (3) Months For Supplies And Materials, One (1) Year For Equipments, From Date Of Acceptance By The Procuring Entity 4. Price Validity Shall Be For A Period Of 120 Days 5. Interested Suppliers Are Required To Submit Their Eligibility Documents Such As Valid And Current Mayor’s Permit/business Permit, Philgeps Registration Number ________, And Income/business Tax Return (for Abcs Above 500k) During The Submission Of Price Quotation. 6. Bidders Shall Submit Original Brochures Showing Certifications Of The Product Being Offered (if Applicable) 7. Omnibus Sworn Statement Must Be Submitted During Submission Of Offer/s Or Before Issuance Of Notice Of Award.(for Abcs Above P50k) Note: Suppliers With Updated Eligibility Documents On File At The Bids And Awards Committee, May No Longer Require Its Re-submission. Quotation Per Item Item No. Item & Description Estimated Unit Of Abc Qty. Unit Of Total Cost Issue Unit Cost 1 Printer , Printing Method: Monochrome Laser Beam Printing 10,000.00 Units Print Speed: A4 - Up To 18ppm; Letter - Up To 19ppm Colors: Monochrome Paper Size: A4, B5, A5, Legal, Letter, Executive, 16k, Envelope Com10, Envelope Monarch, Envelope C5, Envelope Dl; Custom: Width 76.2 To 216 X Length 188x356mm Resolution: 600x600 Dpi Others: Cartridge 325(1600 Pages Capacity), Usb 2.0 Interface, 32mb Device Memory, 870w Maximum Power, 200-800 Pages Print Volume 8 2 Printer , Print Method: On-demand Inkjet (piezoelectric) 7,500.00 Unit Print Speed: Up To 9.0 Ipm / 4.8 Ipm Print Resolution: 720 X 720 Dpi Or Higher Max. Paper Size: 8.5 X 44" Warranty: 2-year Warranty Or 20,000 Pages 1 3 Printer , Color Wifi Multifunction 12,500.00 Unit Function: Print, Scan, Copy, Print Speed: Up To 33.0 Ppm / 15.0 Ppm Print Resolution: 5760 X 1440 Dpi, Copy Speed: (iso 29183, A4) 7.7 Ipm / 3.8 Ipm Max Copy Resolution: 600 X 600 Dpi, Max Copies From Standalone: 20copies, Max Copy Size: A4, Letter, Flatbed Colour Image Scanner, Cis Sensor, Optical Resolution: 1200 X 2400 Dpi, Scan Speed: Up To 11 Sec / 28 Sec, Maximum Scan Area: 216 X 297 Mm, Standard Paper Input Capacity: Up To 100 Sheets Of Plain Paper (80 G/m2), Number Of Paper Trays: 1, Maximum Paper Size: 215.9 X 1200 Mm, Usb 2.0, Warranty Coverage Of Up To 2 Years Or 30k Prints, Whichever Comes First 1 Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110010003; Pr.no.24 - 1645 Page 1 Of 5 Standard Form Number: Sf-good-60 Revised On: May 24, 2004 Standard Form Title: Request For Quotation Republic Of The Philippines Provincial Government Of South Cotabato Bids And Awards Committee Capitol Compound, Alunan Avenue, City Of Koronadal Tel. No. (083) 228-9951 1. All Entries Must Be Handwritten (legible)/ Typewritten 2. Delivery Period Within 10 Calendar Days Upon Receipt Of The Notice To Proceed Note: Date: Svp 24 - 1396 October 30, 2024 Quotation No. Please Quote Your Lowest Price On The Items Listed Below, Subject To The General Conditions Below, Stating The Shortest Time Of Delivery And Submit Your Quotation Duly Signed By Your Representative Not Later Than November 12, 2024 12:00 Noon Provincial Legal Officer Bac Chairman (sgd.) Atty. Marnito B. Cosep 3. Warranty Shall Be For Period Of Three (3) Months For Supplies And Materials, One (1) Year For Equipments, From Date Of Acceptance By The Procuring Entity 4. Price Validity Shall Be For A Period Of 120 Days 5. Interested Suppliers Are Required To Submit Their Eligibility Documents Such As Valid And Current Mayor’s Permit/business Permit, Philgeps Registration Number ________, And Income/business Tax Return (for Abcs Above 500k) During The Submission Of Price Quotation. 6. Bidders Shall Submit Original Brochures Showing Certifications Of The Product Being Offered (if Applicable) 7. Omnibus Sworn Statement Must Be Submitted During Submission Of Offer/s Or Before Issuance Of Notice Of Award.(for Abcs Above P50k) Note: Suppliers With Updated Eligibility Documents On File At The Bids And Awards Committee, May No Longer Require Its Re-submission. Quotation Per Item Item No. Item & Description Estimated Unit Of Abc Qty. Unit Of Total Cost Issue Unit Cost 4 Printer , Color Wifi Multifunction 12,500.00 Unit Function: Print, Scan, Copy, Print Speed: Up To 33.0 Ppm / 15.0 Ppm Print Resolution: 5760 X 1440 Dpi, Copy Speed: (iso 29183, A4) 7.7 Ipm / 3.8 Ipm Max Copy Resolution: 600 X 600 Dpi, Max Copies From Standalone: 20copies, Max Copy Size: A4, Letter, Flatbed Colour Image Scanner, Cis Sensor, Optical Resolution: 1200 X 2400 Dpi, Scan Speed: Up To 11 Sec / 28 Sec, Maximum Scan Area: 216 X 297 Mm, Standard Paper Input Capacity: Up To 100 Sheets Of Plain Paper (80 G/m2), Number Of Paper Trays: 1, Maximum Paper Size: 215.9 X 1200 Mm, Usb 2.0, Warranty Coverage Of Up To 2 Years Or 30k Prints, Whichever Comes First 1 5 Desktop Computer , Ryzen 3 Or Core I3 13100 3.4ghz 12mb Smart Cache Or 35,000.00 Sets Higher Compatible H610m Motherboard Or Higher 1tb M.2 Pcie Nvme Ssd, 8gb Ddr4 Memory On Board Hd Video Graphics, 21.5" Ips Fhd 75hz Monitor Gigabit Lan,650watts 80+ Bronze Rated Power Supply Heavy Duty Atx Black Casing, Combo Usb Keyboard And Mouse W/ Pad Multimedea 2:1 Speaker System, 650va 375watts Ups 1 Year Warranty On Parts And Service 8 6 Fingerprint Scanner , Fingerprint Scanner 5,300.00 Pcs Optical Fingerprint Scanning, 5.0 Vdc ±5% Supplied By Usb Output Image Resolution: 512 Dpi / 8-bit Grayscale (256 Gray Levels) Usb 2.0 Full-speed High Power Device "scan Capture Area : 14.6 Mm (nom. Width); 18.1 Mm (nom. Length) 2 Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110010003; Pr.no.24 - 1645 Page 2 Of 5 Standard Form Number: Sf-good-60 Revised On: May 24, 2004 Standard Form Title: Request For Quotation Republic Of The Philippines Provincial Government Of South Cotabato Bids And Awards Committee Capitol Compound, Alunan Avenue, City Of Koronadal Tel. No. (083) 228-9951 1. All Entries Must Be Handwritten (legible)/ Typewritten 2. Delivery Period Within 10 Calendar Days Upon Receipt Of The Notice To Proceed Note: Date: Svp 24 - 1396 October 30, 2024 Quotation No. Please Quote Your Lowest Price On The Items Listed Below, Subject To The General Conditions Below, Stating The Shortest Time Of Delivery And Submit Your Quotation Duly Signed By Your Representative Not Later Than November 12, 2024 12:00 Noon Provincial Legal Officer Bac Chairman (sgd.) Atty. Marnito B. Cosep 3. Warranty Shall Be For Period Of Three (3) Months For Supplies And Materials, One (1) Year For Equipments, From Date Of Acceptance By The Procuring Entity 4. Price Validity Shall Be For A Period Of 120 Days 5. Interested Suppliers Are Required To Submit Their Eligibility Documents Such As Valid And Current Mayor’s Permit/business Permit, Philgeps Registration Number ________, And Income/business Tax Return (for Abcs Above 500k) During The Submission Of Price Quotation. 6. Bidders Shall Submit Original Brochures Showing Certifications Of The Product Being Offered (if Applicable) 7. Omnibus Sworn Statement Must Be Submitted During Submission Of Offer/s Or Before Issuance Of Notice Of Award.(for Abcs Above P50k) Note: Suppliers With Updated Eligibility Documents On File At The Bids And Awards Committee, May No Longer Require Its Re-submission. Quotation Per Item Item No. Item & Description Estimated Unit Of Abc Qty. Unit Of Total Cost Issue Unit Cost " 7 Desktop Computer , Desktop Computer 40,000.00 Sets Core I5 13400 2.5ghz 20mb Smart Cache Or Higher Compatible H610 Motherboard W/ Gigabit Lan Or Higher 8gb Ddr4-3200mhz Memory Or Equivalent 1tb Nv2 M.2 Nvme Pcie4 Ssd, 2gb Gt730 Video Card 21.5" Fhd 75hz Ips Monitor, 650watts 80+ Bronze Rated Power Supply Heavy Duty Black Atx Casing, 1000va 500watts Ups W/ 8 Outlets, Usb Combo Keyboard With Mouse And Mouse Pad Conditions: (1) Pc 1 Year Warranty On Parts And Service, Ups 2 Years (2) Equipment Under Warranty Shall Be Checked And Diagnose Within A Maximum Of 48hrs Upon Received Of The Equipment. In Case The Repair Will Took More Than 48hrs, The Suppliers/dealers Shall Provide A Service Unit With The Same Specification Or Higher. (3) Suppliers/dealers Shall Replace The Equipment Immediately At No Charge With The Same Specification Or Higher And Has Agreed By The End User, In Case The Unit Has A Factory Defect That Cannot Be Repaired. (4) Suppliers/dealers Shall Have A Service Center With In Socsargen Area. 2 8 Ups , Ups 3,450.00 Unit 1000 Va, 500 Watts, Automatic Voltage Regulation (avr) Generator Compatibility, Rated Input Current ( A ): 4.55 Outlet Type: As X 8, Runtime At 200w ( Min ): 4.5 Surge Suppression ( Joules ): 150, Emi/rfi Filtration 1 Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110010003; Pr.no.24 - 1645 Page 3 Of 5 X-x-x Page 5 Follows X-x-x Note: "please Indicate Brand" Note: For Use Of Pto-sb#4 Source Of Fund: Pto-1091 - 5-02-03-010 - Mooe- 24 - 10 -22237 Approved Budget: P 486,550.00 Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110010003; Pr.no.24 - 1645 Page 4 Of 5 Standard Form Number: Sf-good-60 Revised On: May 24, 2004 Standard Form Title: Request For Quotation Republic Of The Philippines Provincial Government Of South Cotabato Bids And Awards Committee Capitol Compound, Alunan Avenue, City Of Koronadal Tel. No. (083) 228-9951 1. All Entries Must Be Handwritten (legible)/ Typewritten 2. Delivery Period Within 10 Calendar Days Upon Receipt Of The Notice To Proceed Note: Date: Svp 24 - 1396 October 30, 2024 Quotation No. Please Quote Your Lowest Price On The Items Listed Below, Subject To The General Conditions Below, Stating The Shortest Time Of Delivery And Submit Your Quotation Duly Signed By Your Representative Not Later Than November 12, 2024 12:00 Noon Provincial Legal Officer Bac Chairman (sgd.) Atty. Marnito B. Cosep 3. Warranty Shall Be For Period Of Three (3) Months For Supplies And Materials, One (1) Year For Equipments, From Date Of Acceptance By The Procuring Entity 4. Price Validity Shall Be For A Period Of 120 Days 5. Interested Suppliers Are Required To Submit Their Eligibility Documents Such As Valid And Current Mayor’s Permit/business Permit, Philgeps Registration Number ________, And Income/business Tax Return (for Abcs Above 500k) During The Submission Of Price Quotation. 6. Bidders Shall Submit Original Brochures Showing Certifications Of The Product Being Offered (if Applicable) 7. Omnibus Sworn Statement Must Be Submitted During Submission Of Offer/s Or Before Issuance Of Notice Of Award.(for Abcs Above P50k) Note: Suppliers With Updated Eligibility Documents On File At The Bids And Awards Committee, May No Longer Require Its Re-submission. Quotation Per Item Item No. Item & Description Estimated Unit Of Abc Qty. Unit Of Total Cost Issue Unit Cost 9 Battery , Aaa, Zero Mercury, Alkaline, 4's/pack 181.75 3 Pcks 10 Battery , Aa, Zero Mercury, Alkaline, 4's/pack 181.75 3 Pcks 11 Gun Tacker , 10mm 2,000.00 1 Pc 12 Gun Tacker , 12mm 3,579.75 1 Pc 13 Gun Tacker Staple Wire , 10mm 44.25 1 Box 14 Gun Tacker Staple Wire , 12mm 47.25 2 Box 15 Marker , Permanent, Broad, Red 38.75 1 Pc 16 Marker , Permanent, Fine, Blue 38.75 3 Pcs 17 Marker , Whiteboard, Black 59.75 2 Pcs 18 Pen , Ballpen, Gel, 1mm, Blue, 25's 1,750.00 1 Box 19 Sticky Notes , 1" X 3", 100 Lvs. 39.25 10 Pads 20 Flash Drive , 32gb 341.00 4 Units X-x-x Nothing Follows X-x-x Note: "please Indicate Brand" Note: For Use Of Pto-sb#4 Source Of Fund: Pto-1091 - 5-02-03-010 - Mooe- 24 - 10 -22237 Approved Budget: P 10,590.00 Brand And Model Delivery Period Warranty Price Validity After Having Carefully Read And Accepted Your General Conditions, I/we Quote You On The Item At Prices Noted Above. Printed Name / Signature Tel. No. / Cellphone No. Email Address Date Powered By Ppdo - Itu Powered By Ppdo - Itu Prepared By: 110010003; Pr.no.24 - 1645 Page 5 Of 5
Closing Date12 Nov 2024
Tender AmountPHP 497.1 K (USD 8.5 K)
Department Of Human Settlement And Urban Development Quezo Tender
Civil And Construction...+1Civil Works Others
Philippines
Details: Description Request For Quotation Doc Control No. : Form-as-pd-002 Revision No: 0 Effectivity Date : 1 September 2023 The Department Of Human Settlements And Urban Development (dhsud) Would Like To Invite Your Company To Submit A Quotation Or Proposal For The Following Procurement Activity: Request For Quotation No. Rfq No. 02-0031, S. 2024 Procurement Activity Lease Of Ngfw Firewall For Dhsud For 3 Months Mode Of Procurement Negotiated Procurement – Small Value Procurement (section 53.9) Approved Budget For The Contract (abc) Two Hundred Ninety Five Thousand Pesos (php295,000.00), Inclusive Of All Existing And Appropriate Government Taxes And Charges. Deadline For The Receipt Of Quotations Or Bid Proposal On Or Before 3:00 Pm, February , 2024. Delivery Schedule Delivery Of Goods/items Shall Be Seven (7) To Twenty (20) Calendar Days Upon Receipt Of The Approved Purchase Order. The Minimum Technical Specifications For The Said Activities Are As Follows: Item No. Qty. Item, Description, & Minimum Specifications 1 3 Mos. Ngfw Firewall Lease 1. Background Of The Item Being Procured A. General Overview Of The Procurement Project I. The Dhsud Kmiss-itid Division Aims To Strengthen The Overall Network Security Infrastructure With Ensured Data Protection And Prevention Of Unauthorized Access. This Shall Be Primarily Achieved Through The Acquisition Of Latest Security Technologies Such As Network Monitoring Tools Capable Of Detecting And Filtering Malicious Traffic. Possible Entry Points Of Intrusions Are Mitigated With The Help Of Sensors And Security Rules And Policies. B. Brief Description Of The Item Being Procured I. As A Network And Infrastructure Recommended Security Practices, A Next Generation Firewall Is A Network Security Equipment Which Monitors Network Flow For Malicious Activities. The Ngfw Will Identify, Log Information, Report, And Attempt To Block Any Harmful Activity That Poses Threat To The Network. Network Traffic In The Dhsud Network Will Be Filtered With Layers Of Security Policies. With Unwanted Traffic Blocked, Dhsud’s Network Becomes Geared Towards Ensuring Data Protection And Meeting Other Security Objectives C. Abc Of The Project And Fund Source I. The Abc Of The Project Is Two Hundred Ninety-five Thousand Pesos Ii. Detailed Financial Breakdown Item Qty Price Lease Of Next-generation Application Firewall, Services, And Support And Networking Equipments 1 Lot Php 295,000 2. Purpose Of The Procurement A. Rationale I. The Main Objective Of This Proposal Is To Continue To Lease Licenses And Support Of Existing Next Generation Firewall Ii. Delivering And Ensuring Network And Data Protection And Unauthorized Access; Detecting And Filtering Malicious Traffic ● Monitoring Network Flow, Identity And Block Any Harmful Activity That Poses Threat To The Network. ● Diagnosis And Resolution Of Problems On The Performance Deficiencies Of The Software. ● Provide Product Patches, Updates, Releases, And New Versions Of The Software ● Health Check Of Firewall Appliance On A Regular Basis. ● Health Checks, Repair Or Replacement Of Defective/malfunctioning Hardware Parts During The Lease Period. ● The Service Provider Shall Provide 24/7 Technical Personnel In Close Coordination With The End User. ● 24x7 Phone, Email And Onsite Nbd Support 3. Mode Of Procurement A. Small Value Procurement 4. Scope Of Work A. Technical Specifications 1. Hardware Requirements (minimum Specifications) 1.1. Next Generation Firewall (1) 1.1.1. Performance 1.1.1.1. The Proposed Solution Must Have 2.5 Gbps Firewall Layer 3 Throughput. 1.1.1.2. The Proposed Solution Must Support At Least 750,000 Connections Per Seconds 1.1.1.3. The Proposed Solution Must Support At Least 20,000 New Connections Per Seconds 1.1.1.4. Can Support 2 Or More Isp Providers 1.1.2. Interface 1.1.2.1. The Proposed Solution Must Have At Least 5*10/100/1000 Base-t Interface. 1.1.2.2. 2x Usb Port 1.1.2.3. 1x Management Port 1.1.2.4. 1x Console Port 1.1.3. Management 1.1.3.1. Management Console Must Be Managed Through Web Interfaces Via Secure Encrypted Connection. 1.1.4. Features 1.1.4.1. Stateful Firewall 1.1.4.2. Ddos Prevention, Arp Spoofing Prevention 1.1.4.3. Anti-virus 1.1.4.4. Anti-malware, On-premise Artificial Intelligence Based Malware Detection Engine 1.1.4.5. Anti-phishing 1.1.4.6. Intrusion Prevention System 1.1.4.7. Web Application Firewall, Semantic Detection Method 1.1.4.8. Ssl Decryption 1.1.4.9. Risk Assessment By On-demand And Real-time Scanner 1.1.4.10. Cloud Sandboxing 1.1.4.11. Cloud Threat Intelligence 1.1.4.12. Ipsec Vpn 1.1.4.13. Ssl Vpn 1.1.4.14. User Authentication And Grouping 1.1.4.15. Web(url) Filtering, Application Control, Bandwidth Management 1.1.4.16. Report Center 1.1.4.17. The Proposed Solution Must Support Security Protection For Pre-attack, During-attack And Post-attack. 1.1.4.18. The Proposed Solution Must Support Security Protection For Business Systems And Network Users. 1.1.5. Firewall 1.1.5.1. The Proposed Solution Must Support Static And Dynamic Package Filtering, Inspection On Well-known Protocols Of Ftp, Http, Smtp, Rtsp, H.323 (q.931, H.245, Rtp/rtcp), Sqlnet, Nms, Pptp, Tcp, Udp 1.1.5.2. The Proposed Solution Must Be Able To Protect Against Attacks Of Land, Smurf, Fraggle, Winnuke, Ping Of Death, Tear Drop, Ip Spoofing, Syn/icmp/udp Flood, Http Get Flood, Dns Query Flood, Arp Cheating, Icmp Redirection, Static And Dynamic Black List, Etc 1.1.5.3. Geo-location Block, Create Rules To Allow Or Block Traffic From Ip Addresses In Specific Countries, Regions And States, Reduce The Attack Possible. 1.1.5.4. Supports Real-time Integration Status Between The Local Firewall And The Cloud-threat Intelligence But Not Limited By Providing: 1.1.5.4.1. The Total Number Of External Attack Events 1.1.5.4.2. The Total Number Of Threats Detected By Cloud Threat Intelligent In The Local Firewall 1.1.6. Intrusion Prevention System 1.1.6.1. The Proposed Solution Must Support Vulnerability Database With At Least 9000+ Entries 1.1.6.2. The Proposed Solution Must Support Separate Server And Endpoint Vulnerability Database Group For Convenient Policy Configuration 1.1.6.3. The Ips System Must Be Able To Block Worms, Trojans, Spyware, Scanning, Dos, Ddos, Vulnerability Exploits, Buffer Overflow Attacks, Abnormal Protocol And Attacks With Evasive Tactic Employed. 1.1.6.4. The Ips Supports Automatically Block, Logging, Upload Gray Threat To The "cloud" 1.1.6.5. The Ips Supports Burp-force Attack Prevention For Ftp, Imap Mssql, Pop3 Smtp, Oracle, Rdp, Smbv1, Smbv2, Smbv3 And So On. 1.1.7. Apt Prevention 1.1.7.1. The Proposed Solution Must Support Apt Detection Of Identifying Botnet, Remote Control Trojans, Malicious Link, And Other Threats. 1.1.7.2. The Proposed Solution Must Support Anti-malware Database With More Than 400,000+ Entries 1.1.7.3. The Proposed Solution Must Be Able To Conduct Cross-module Intelligent Correction Of Ips, Waf And Apt Detection Modules To Generate Temporary Fw Rules To Lock The Suspicious Ip When Malicious Behavior From That Ip Is Detected By Any Of The Modules. 1.1.7.4. Apt Supports Sandbox Dynamic Detection Via Security Cloud 1.1.7.5. Apt Supports To Detect Ddos Attack From Intranet 1.1.7.6. Apt Can Effectively Distinguish The Hazardous Traffic Flow In The Common Application Of The Rdp, Ssl, Imap, Smtp, Pop3, Ftp,, Dns,, Http, Web, And So On Traffic Flow , But Also Can Be Used For The Normal Operation Of Non-standard Port For Early Warning. 1.1.7.7. Support Honeypot Feature And Locate The Real Host Ip Address Of The Intranet Infected Botnet Virus 1.1.7.8. Support In-depth Analysis On Detected Malware Or Trojan Behaviors By Demonstrating Interaction & Communication Between External C&c Botnets And Other Suspicious Events. 1.1.8. Risk Assessment And Prevention 1.1.8.1. The Proposed Solution Must Provide Risk Assessment Module That Allows To Scan And Identify Security Loopholes Such As Open Port, System Vulnerabilities, Weak Passwords And Other Risks Of The Protected Servers 1.1.8.2. The Proposed Solution Must Support Real-time Vulnerability Analysis, Includes The Underlying Software Vulnerability Analysis, Web Application Risk Analysis, Web Unsafe Configuration Detection And Server Weak Password Detection, And Generate Real-time Analysis Reports. That Can Be Deployed In Mirror Mode To Discover System Vulnerabilities Within A Protected Network In Real-time. 1.1.8.3. The Real-time Vulnerability Is Also Supported To Detect For The Website If It Existed Backlink, And Can Record The Type Of The Black Link And The Location Of Backlink. 1.1.8.4. Risk Assessment And Scanning Results Must Be Shown And Generated With Corresponding Reports With Detailed Description Of The Issues And Recommended Solution. 1.1.8.5. Risk Assessment Module Must Be Able To Be Affiliated With The Ips And Server Protection Module To Automatically Generate The Protection Policies 1.1.8.6. Threat Alerts Is Able To Actively Push The Current Popular Zero Day Or High-risk Vulnerabilities, And Can Provide Vulnerability Detection Tools For Business Scan, According To The Results Of Scan, It Can Generate Safety Protection Policies. 1.1.9. Web Application Firewall 1.1.9.1. The Proposed Solution Should Come With Built-in Advanced Waf Capability In Firewall But Not Separate Appliance 1.1.9.2. The Proposed Solution Must Be Able To Defend Against The 10 Major Web-based Attacks Identified By The Open Web Application Security Project (owasp) , Including Sql Injection, Xss, Csrf, Etc., By Semantic Detection Engine. 1.1.9.3. The Proposed Solution Must Support Waf Database That Hosts Not Less Than 5000 Web-based Attacks Rules 1.1.9.4. The Proposed Solution Must Be Able To Perform Inspection Of The Content At The Perimeter For Incoming Traffic. Only To Allow Input Parameters That Conform To The Application Functionalities Required Of The Web Application And No Malicious Input Parameters 1.1.9.5. The Proposed Solution Must Be Able To Restrict Suspicious File Uploading With File Types Of Asp, Asa, Exe, Jsp, Php,aspx,php3,php4,phtml, Vbs Etc. 1.1.9.6. The Proposed Solution Must Support Application Hiding Of Http Error Pages Replacement, Http (s) Response Headers Hidden, And Ftp Server And Software Version Information Hidden, Etc. 1.1.9.7. Support Cc, Csrf And Cookie Attack Prevention. 1.1.9.8. Should Support Automatic On-demand Web Application Decoding 1.1.9.9. Support Password Protection, Including Ftp Weak Password Detection, Web Login Weak Password Detection, Web Login Plaintext Transmission Detection, Password Brute Force Protection 1.1.10. Anti-defacement 1.1.10.1. The Proposed Solution Must Support Server Access Verification For Administrator Website, Avoid Website Defacement 1.1.11. Data Breach Protection 1.1.11.1. Allow To Define Multiple Types Of Sensitive Information Based On The Characteristics Of Stored Data, The Sensitive Information Includes Email Account Information, Md5 Encrypted Passwords. 1.1.11.2. The Proposed Solution Must Be Able To Restrict Suspicious File Downloading With File Types Of Dat, Bak,dmp,backup, Asa,log, Fp, Frx, Frt, Cnf, Ade,mde, Db, Ldb,etc. 1.1.12. Anti-virus 1.1.12.1. Stream-based Antivirus For Http, Ftp, Smtp And Pop3 , Smbv3 Protocols, Etc. 1.1.12.2. The Proposed Solution Must Support Built-in Artificial Intelligence Capability To Detect Malware, Virus And Ransomware Variants And Provide The Malware Analysis Report 1.1.12.3. Should Support Compressed File Malware Inspection, Up To 16 Layer 1.1.12.4. Should Support Cloud Based Threat Intelligence And Analytics 1.1.13. Content Security 1.1.13.1. Mail Protect Support Pop3, Smtp, Imap, Pop3s, Smtps, Imaps And Other Specific Port. 1.1.13.2. Mail Protect Support Mail Collision Attack Prevention And Anti-phishing. 1.1.13.3. Mail Attachment Can Be Detected By Anti-virus. 1.1.13.4. Support Mail Attachment Filter And Http/ftp Download/upload Filter. 1.1.13.5. When Users Receive Malicious Mail, The Proposed Solution Will Tamper The Mail Subject 1.1.14. Access Management 1.1.14.1. The Proposed Solution Must Support Up To Eight User Identification Methods Such As Active Directory (ad) Authentication And Remote Authentication Dial-in User Service (radius) 1.1.14.2. The Proposed Solution Should Support Internet Application Identification Database With More Than 9000+ Entries And Url Database With More Than Hundreds Of Millions Entries That Updated With Cloud-based Technologies 1.1.14.3. The Proposed Solution Must Support Policy Configuration Oriented Toward Users And Applications For Web Filter, Application Control And Bandwidth Management 1.1.14.4. The Proposed Solution Must Support Security Policy Optimizer, Which Helps: 1.1.14.5. 1) Identify The Redundant Policy, Expired Policy, Conflict Policy Etc. 1.1.14.6. 2) Be Able To Track The Acl Policy Life Cycle, Help To Track Every Change That Have Been Done To The Policy In A Specific Period Of Time 1.1.14.7. The Proposed Solution Must Support Link Load Balance Per Traffic Load As Well As Application Type In Occasion Of Multiple Internet Lines 1.1.15. Reporting 1.1.15.1. The Proposed Solution Must Support Built-in Report Center, Which Provides Comprehensive Security Analyzing Reports Including But Not Limit To Attack Trends By “all Attacks” And “valid Attacks”; Security Rating By “business Server Security”, “user Security” And “vulnerability”; Business Server Security By Suffered Attack Times Ranking; Vulnerability Assessment 1.1.15.2. The Proposed Solution Must Support Business Model Learning, Which Will Help To Simplify The Security Operation For Web Servers, And Reduce The False Positives. 1.1.15.3. Support The Detailed Logs For Security Issues Such As Dos Attack, Web Attack, Ips, Viruses, Website Access, Application Control, User Login And Os Configuration. 1.1.15.4. Support Detailed Threats Analysis For Specific Attack By Description, Target, Solution; Support Security Analysis For Specific Server With Attack Type, Attack Source, Etc. 1.1.15.5. The Report Center Must Provide Full Visibility To Network, Endpoint Clients And The Business Servers With Multi-dimensional Analysis Of Risks, Vulnerabilities, Attacks, Threats, Traffic And Behaviors 1.1.15.6. Support Pdf Format And Automatically Send To Predefined Mailbox On Daily/weekly/monthly Basis 1.1.15.7. Supports Automatic Generation Of Comprehensive Security Risk Reports. The Content Of The Report Should Reflect But Not Limited: 1.1.15.7.1. The Overall Security Level Of The Protected Network Object 1.1.15.7.2. The Vulnerability Information & Forensic Evidence Each Attack 1.1.16. Deployment 1.1.16.1. Gateway (route Mode) 1.1.16.2. Bridge Mode 1.1.16.3. Mirror Mode 1.1.16.4. Multiple Bridge Mode(2- 4 Bridges 1.1.16.5. The Proposed Solution Must Support Build-in Auto Hardware Bypass In The Event Of Hardware Failure 1.1.16.6. Support Quick Deployment From Central Management Console 1.1.16.7. Must Be Compatible With The Existing Dhsud Network. 1.1.17. Vpn 1.1.17.1. The Proposed Solution Must Support To Build Proprietary Vpn Tunnel Between Hq And Branches 1.1.17.2. Ipsec Vpn 1.1.17.3. Authentication Algorithm: Md5/sha-1 1.1.17.4. Encryption Algorithm: Des/3des/aes128 Hash:md5/sha 1.1.17.5. Ssl Vpn 1.1.17.6. Source Type: L3vpn Resources, Tcp Resources. 1.1.17.7. Operating System Supported: Win Xp/win 7/win 8/win10/win11/mac 1.1.17.8. Supports 2fa With Google Authenticator, Microsoft Authenticator 1.1.18. Real-time Visibility 1.1.18.1. Real Time Provides Cpu, Memory, Disk Usage, Session Number, The Number Of Online Users, The Network Interface, Box Resource Information 1.1.18.2. The Proposed Solution Must Be Provided Real-time User Ranking / Real-time Application Ranking / Real-time Host Ranking 1.1.18.3. The Proposed Solution Must Provide Real-time Attack Map, Include Top Attack Country And Counting, Real-time Attacks And Threat Detail 1.1.18.4. Provide Information Security Incidents, Including Recently Security Incidents, Server Security Incidents, Terminal Security Incidents 1.1.18.5. In Security Status,it Displays The Current Network Risks That Need To Be Handled, And Top Attacks, Bots Show The Threat Stage And Security Rating. 1.1.18.6. Top Session Can Display Real-time, Last 24 Hours, Last 7 Days Of The Current Session And The New Session. 1.1.19. Routing 1.1.19.1. Supports Static Route, Ripv1 & V2, Ospfv2 And Bgp 1.1.19.2. The Proposed Solution Must Be Able To Support But Not Limited To Intelligent Route Selection Based On Source And Destination Ip, Port, Protocol And Country-based Ip Address 1.1.19.3. Support Dns-mapping 1.1.19.4. Support Custom Intranet Dns Server Address To Avoid Botnet Detection Misjudgment Dns Server 1.1.20. Certification 1.1.20.1. The Proposed Solution Must Be Certified By Icsa Labs. 1.1.20.2. The Proposed Solution Must Have Aaa Rating At Cyberratings Enterprise Firewall. 1.1.20.3. The Proposed Solution Must Be In Visionaries Or Higher Level Of Gartner Magic Quadrant For Network Firewalls 2021 1.1.20.4. The Proposed Solution Must Be Cmmi L5 Certified. 1.1.20.5. Iso 9001:2015 1.1.20.6. Iso/iec 27001:2013 1.1.20.7. The Project Implementer Must Be Cissp Certified. 1.2. Scope Of Works 1.2.1.1. Diagnosis And Resolution Of Problems On The Performance Deficiencies Of The Software/firmware/licenses. 1.2.1.2. Provide Product Patches, Updates, Releases, And New Versions Of The Software/firmware/licenses 1.2.1.3. Health Check Of Firewall Appliance On A Regular Basis (at Least Once A Month) 1.2.1.4. Health Checks, Repair Or Replacement Of Defective/malfunctioning Hardware Parts During The Lease Period. 1.2.1.5. The Service Provider Shall Provide 24/7 Technical Personnel In Close Coordination With The End User. B. Deliverables I. Three (3) Months Of Support During The Lease Period C. Duration Of The Contract I. The Overall Duration Of The Contract Is One Hundred (90) Calendar Days For The Supply, Delivery, Installation, Configuration, And Training With Provision For Extension. While The Necessary Services Are Required To Be Provided For Three (3) Months After Implementation. D. Service Support Requirements I. The Prospective Bidder Must Have A Team Of Certified Engineers For The Installation And Configuration For Local Deployment Using The Offered Solution. The Bidder Must Provide Copies Of Certificates From The Manufacturer That Engineers Are Certified/qualified To Install And Configure The System. Ii. The Prospective Bidder Must Provide Maintenance Services Thru Corrective/remedial Maintenance And Quarterly Health Checks During The Duration Of The Contract. Iii. The Prospective Bidder Must Ensure Service Units Are Readily Available During Down-time During The Contract Period. Service Units Should Be Delivered On-site Next Business Day When The Hardware Cannot Be Repaired On Site Due To Failure, Within Metro Manila. Iv. The Principal Manufacturer Must Provide Unlimited E-mail Submission And Telephone Access 24x7. Prospective Bidder Must Provide Procedures Support And Problem Escalation, Technical Phone Support 24x7; Response Time Must Be Within Four (4) Hours Upon Receipt Of Notification From Dhsud End-user/designated Personnel. E. Minimum Requirements For Bidders: I. Valid And Current Certificate Of Distributorship/resellership/dealership Issued By Manufacturer. If The Certificate Is Not Issued By The Manufacturer, The Bidder Must Also Present An Appropriate Document Showing The Relationship Between The Manufacturer And The Issuing Company. 5. Acceptance/testing Criteria And Process A. User Acceptance I. Proposed Product Must Conform With The Technical Specifications And Schedule Of Requirements. 6. Payment Terms And Schedule Activities/milestone Duration % Progress Health Check, Inspection And Acceptance Of Next Generation Firewall Within 15 Days From Notice To Proceed 10% Of The Contract Price Monthly Leasing Of Next Generation Application Firewall Monthly Payment For Three (3) Months After The Conduct Of Successful Training And Submission Of Complete Documentation 90% Of The Contract Price 7. Timelines For The Implementation Of The Project A. Delivery Schedule Item Delivery Date Health Check, Inspection And Acceptance With Technical Report/s Within Fifteen (15) Calendar Days From Receipt Of Notice To Proceed. Knowledge Transfer For At Least Six (6) Dhsud Personnel Submission Of Complete Project Documentation. Within Fifteen (15) Calendar Days From Receipt Of Notice To Proceed. Three (3) Months Of Lease, Services And Support Will Commence After Project Implementation Terms And Conditions: 1. Payment Shall Be Made Upon Completion Of Service/delivery And Submission Of The Supporting Documents (e.g., Delivery Receipt, Sales Invoice, Billing Statement, Warranty Certificate If Applicable, And Other Documents As May Be Required In The Technical Specifications); 2. Kindly Accomplish The Attached Reply Slip Correctly And Accurately. Please Do Not Alter The Contents Of The Form In Any Way; 3. All Technical Specifications Are Mandatory. Failure To Comply With Any Of The Said Requirements Shall Be A Cause For The Disqualification Of Your Quotation; 4. The Department Shall Have The Right To Inspect The Goods To Check Its Conformity With The Required Minimum Technical Specifications; 5. Issuance Of Official Receipts (or) Or Sales Invoice (si) In The Name Of The Department Of Human Settlements And Urban Development (dhsud) Is Mandatory. The Supplier Shall Bear The Cost Of Mailing The Ors Or Sis. The Supplier Shall Be Responsible For Bearing Any Bank Charges And/or Service Charges That May Be Incurred By The Department In Case Of Payment Requests Via Check Deposit; 6. Please Submit The Latest Copy Or E-copy Of The Following Documentary Requirements: A. Philgeps Registration Number / Certificate Of Philgeps Membership; B. 2024 Mayor’s Permit/business Permit; (note: In Case The Permit Has Recently Expired, Please Submit The Old Permit And Attach The Official Receipt For The Renewal Application Thereof.) C. Signed Omnibus Sworn Statement (oss); Note: A Notarized Omnibus Sworn Statement (oss) Shall Be Submitted By The Lcrb Or Scrb Prior To The Processing Of Payment. If The Authorized Representative Listed On The Reply Slip Is Not The Same Person Who Executed The Omnibus Sworn Statement (oss) Kindly Attach A Copy Of The Notarized Special Power Of Attorney (spa) Together With The Valid Government-issued Identification Card Of Both Signatories. D. Supporting Documents (as May Be Applicable): For Sole Proprietorships – Dti Business Name Registration; For Partnerships Or Corporations - A Notarized Special Power Of Attorney, Or A Notarized Secretary’s Certificate, Whichever Is Applicable (bidders With Previously Submitted Eligibility Requirements, Provided They Are Current And Updated, Are No Longer Required To Submit The Said Documents.) Your Quotation Or Bid Proposal Must Be Submitted Together With The Attached Reply Slip And The Above Mentioned Documentary Requirements Through Personal Delivery, And In A Sealed Envelope, To The Procurement Division Located At The 8th Floor, Dhsud Building, Kalayaan Avenue Corner Mayaman Street, Diliman, Quezon City, Or Through Electronic Mail At Procurement@dhsud.gov.ph. The Dhsud Bids And Awards Committee (bac), Through The Concerned End-user Unit And The Bac Secretariat, Shall Recommend The Award Of The Contract To The Head Of The End-user Unit Or Implementing Office, Of The Service Provider With The Single/lowest Calculated And Responsive Quotation Slrq/(lcrq) Pursuant To Section 53.10 Of The 2016 Revised Irr Of Ra 9184. With The End View Of Obtaining The Contract Most Advantageous To The Government Pursuant To Sec. 41 Of The 2016 Revised Irr Of Ra 9184, Dhsud Reserves The Right To Reject Any And All Quotations/bids, To Annul The Procurement Process, To Declare A Failure Of Bidding, To Reject All Quotations/bids At Any Time Prior To Contract Award, Or Not To Award The Contract, Without Thereby Incurring Any Liability To The Affected Bidder/s. For Questions And/or Clarifications, Please Contact The Procurement Division At Telephone Number 8424-4080 (local 1833). (original Signed) Anilaine L. Gamba Oic, Procurement Division Reply Slip Procurement: Lease Of Ngfw Firewall For Dhsud For 3 Months Request For Quotation No.: 02-0031, S. 2024 _______________ Date Anilaine L. Gamba Oic-procurement Division Department Of Human Settlements And Urban Development 8th Floor, Administrative Services Dhsud Bldg. Kalayaan Avenue, Cor. Mayaman St. Quezon City Dear Ms. Gamba: This Is To Submit The Following Bid Quotation/proposal For The Subject Procurement With A Total Bid Price Of __________________________________ Pesos (php________.00), Inclusive Of All Existing And Appropriate Government Taxes And Charges: Quantity Unit Description I Hereby Certify That The Above Bid Quotation/proposal Is True And Correct, And I Accept The Rights Of The Department Of Human Settlements And Urban Development, As The Procuring Entity, Under Section 41 Of The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Thank You. Truly Yours, Name Of Company: ____________________________________________ Name Of Authorized Representative: _______________________________ Designation/position: ____________________________________________ Address: _____________________________________________________ Telephone No./mobile No.: _______________________________________ Email Address: ________________________________________________ Philgeps Registration No. : ______________________________________ Landbank Account No.: _________________________________________ If With Ada, Kindly Indicate The Landbank Account Name And Account Number; If None, Please Indicate To Whom Checks Should Be Made Payable To : _____________________________________ Tin: __________________________ Vat-registered: Vat󠄀 ( ) Non-vat ( ) Signature: ____________________________________________________ Omnibus Sworn Statement (revised) [shall Be Submitted With The Bid] [kindly Fill Out This Template Accordingly By Completing The Needed Information And Deleting The Non-applicable Provisions That May Be Deleted.] _________________________________________________________________________ Republic Of The Philippines ) City/municipality Of ______ ) S.s. Affidavit I, [name Of Affiant], Of Legal Age, [civil Status], [nationality], And Residing At [address Of Affiant], After Having Been Duly Sworn In Accordance With Law, Do Hereby Depose And State That: 1. [select One, Delete The Other:] [if A Sole Proprietorship:] I Am The Sole Proprietor Or Authorized Representative Of [name Of Bidder] With Office Address At [address Of Bidder]; [if A Partnership, Corporation, Cooperative, Or Joint Venture:] I Am The Duly Authorized And Designated Representative Of [name Of Bidder] With Office Address At [address Of Bidder]; 2. [select One, Delete The Other:] [if A Sole Proprietorship:] As The Owner And Sole Proprietor, Or Authorized Representative Of [name Of Bidder], I Have Full Power And Authority To Do, Execute And Perform Any And All Acts Necessary To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract For [name Of The Project] Of The [name Of The Procuring Entity], As Shown In The Attached Duly Notarized Special Power Of Attorney; [if A Partnership, Corporation, Cooperative, Or Joint Venture:] I Am Granted Full Power And Authority To Do, Execute And Perform Any And All Acts Necessary To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract For [name Of The Project] Of The [name Of The Procuring Entity], As Shown In The Attached [state Title Of Attached Document Showing Proof Of Authorization (e.g., Duly Notarized Secretary’s Certificate, Board/partnership Resolution, Or Special Power Of Attorney, Whichever Is Applicable;)]; 3. [name Of Bidder] Is Not “blacklisted” Or Barred From Bidding By The Government Of The Philippines Or Any Of Its Agencies, Offices, Corporations, Or Local Government Units, Foreign Government/foreign Or International Financing Institution Whose Blacklisting Rules Have Been Recognized By The Government Procurement Policy Board, By Itself Or By Relation, Membership, Association, Affiliation, Or Controlling Interest With Another Blacklisted Person Or Entity As Defined And Provided For In The Uniform Guidelines On Blacklisting; 4. Each Of The Documents Submitted In Satisfaction Of The Bidding Requirements Is An Authentic Copy Of The Original, Complete, And All Statements And Information Provided Therein Are True And Correct; 5. [name Of Bidder] Is Authorizing The Head Of The Procuring Entity Or Its Duly Authorized Representative(s) To Verify All The Documents Submitted; 6. [select One, Delete The Rest:] [if A Sole Proprietorship:] The Owner Or Sole Proprietor Is Not Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; [if A Partnership Or Cooperative:] None Of The Officers And Members Of [name Of Bidder] Is Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; [if A Corporation Or Joint Venture:] None Of The Officers, Directors, And Controlling Stockholders Of [name Of Bidder] Is Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; 7. [name Of Bidder] Complies With Existing Labor Laws And Standards; And 8. [name Of Bidder] Is Aware Of And Has Undertaken The Responsibilities As A Bidder In Compliance With The Philippine Bidding Documents, Which Includes: A. Carefully Examining All Of The Bidding Documents; B. Acknowledging All Conditions, Local Or Otherwise, Affecting The Implementation Of The Contract; C. Making An Estimate Of The Facilities Available And Needed For The Contract To Be Bid, If Any; And D. Inquiring Or Securing Supplemental/bid Bulletin(s) Issued For The [name Of The Project]. 9. [name Of Bidder] Did Not Give Or Pay Directly Or Indirectly, Any Commission, Amount, Fee, Or Any Form Of Consideration, Pecuniary Or Otherwise, To Any Person Or Official, Personnel Or Representative Of The Government In Relation To Any Procurement Project Or Activity. 10. In Case Advance Payment Was Made Or Given, Failure To Perform Or Deliver Any Of The Obligations And Undertakings In The Contract Shall Be Sufficient Grounds To Constitute Criminal Liability For Swindling (estafa) Or The Commission Of Fraud With Unfaithfulness Or Abuse Of Confidence Through Misappropriating Or Converting Any Payment Received By A Person Or Entity Under An Obligation Involving The Duty To Deliver Certain Goods Or Services, To The Prejudice Of The Public And The Government Of The Philippines Pursuant To Article 315 Of Act No. 3815 S. 1930, As Amended, Or The Revised Penal Code. In Witness Whereof, I Have Hereunto Set My Hand This __ Day Of ___, 20__ At ____________, Philippines. [insert Name Of Bidder Or Its Authorized Representative] [insert Signatory’s Legal Capacity] Affiant [jurat] [format Shall Be Based On The Latest Rules On Notarial Practice]
Closing Date12 Feb 2024
Tender AmountPHP 295 K (USD 5.2 K)
Department Of Human Settlement And Urban Development Quezo Tender
Civil And Construction...+1Civil Works Others
Philippines
Details: Description Request For Quotation Doc Control No. : Form-as-pd-002 Revision No: 0 Effectivity Date : 1 September 2023 The Department Of Human Settlements And Urban Development (dhsud) Would Like To Invite Your Company To Submit A Quotation Or Proposal For The Following Procurement Activity: Request For Quotation No. Rfq No. 02-0057, S. 2024 Procurement Activity Lease Of Ngfw Firewall For Dhsud For 3 Months (1st Rebidding) Mode Of Procurement Negotiated Procurement – Small Value Procurement (section 53.9) Approved Budget For The Contract (abc) Two Hundred Ninety Five Thousand Pesos (php295,000.00), Inclusive Of All Existing And Appropriate Government Taxes And Charges. Deadline For The Receipt Of Quotations Or Bid Proposal On Or Before 3:00 Pm, February 26, 2024. Delivery Schedule Delivery Of Goods/items Shall Be Seven (7) To Twenty (20) Calendar Days Upon Receipt Of The Approved Purchase Order. The Minimum Technical Specifications For The Said Activities Are As Follows: Item No. Qty. Item, Description, & Minimum Specifications 1 3 Mos. Ngfw Firewall Lease 1. Background Of The Item Being Procured A. General Overview Of The Procurement Project I. The Dhsud Kmiss-itid Division Aims To Strengthen The Overall Network Security Infrastructure With Ensured Data Protection And Prevention Of Unauthorized Access. This Shall Be Primarily Achieved Through The Acquisition Of Latest Security Technologies Such As Network Monitoring Tools Capable Of Detecting And Filtering Malicious Traffic. Possible Entry Points Of Intrusions Are Mitigated With The Help Of Sensors And Security Rules And Policies. B. Brief Description Of The Item Being Procured I. As A Network And Infrastructure Recommended Security Practices, A Next Generation Firewall Is A Network Security Equipment Which Monitors Network Flow For Malicious Activities. The Ngfw Will Identify, Log Information, Report, And Attempt To Block Any Harmful Activity That Poses Threat To The Network. Network Traffic In The Dhsud Network Will Be Filtered With Layers Of Security Policies. With Unwanted Traffic Blocked, Dhsud’s Network Becomes Geared Towards Ensuring Data Protection And Meeting Other Security Objectives C. Abc Of The Project And Fund Source I. The Abc Of The Project Is Two Hundred Ninety-five Thousand Pesos Ii. Detailed Financial Breakdown Item Qty Price Lease Of Next-generation Application Firewall, Services, And Support And Networking Equipments 1 Lot Php 295,000 2. Purpose Of The Procurement A. Rationale I. The Main Objective Of This Proposal Is To Continue To Lease Licenses And Support Of Existing Next Generation Firewall Ii. Delivering And Ensuring Network And Data Protection And Unauthorized Access; Detecting And Filtering Malicious Traffic ● Monitoring Network Flow, Identity And Block Any Harmful Activity That Poses Threat To The Network. ● Diagnosis And Resolution Of Problems On The Performance Deficiencies Of The Software. ● Provide Product Patches, Updates, Releases, And New Versions Of The Software ● Health Check Of Firewall Appliance On A Regular Basis. ● Health Checks, Repair Or Replacement Of Defective/malfunctioning Hardware Parts During The Lease Period. ● The Service Provider Shall Provide 24/7 Technical Personnel In Close Coordination With The End User. ● 24x7 Phone, Email And Onsite Nbd Support 3. Mode Of Procurement A. Small Value Procurement 4. Scope Of Work A. Technical Specifications 1. Hardware Requirements (minimum Specifications) 1.1. Next Generation Firewall (1) 1.1.1. Performance 1.1.1.1. The Proposed Solution Must Have 2.5 Gbps Firewall Layer 3 Throughput. 1.1.1.2. The Proposed Solution Must Support At Least 750,000 Connections Per Seconds 1.1.1.3. The Proposed Solution Must Support At Least 20,000 New Connections Per Seconds 1.1.1.4. Can Support 2 Or More Isp Providers 1.1.2. Interface 1.1.2.1. The Proposed Solution Must Have At Least 5*10/100/1000 Base-t Interface. 1.1.2.2. 2x Usb Port 1.1.2.3. 1x Management Port 1.1.2.4. 1x Console Port 1.1.3. Management 1.1.3.1. Management Console Must Be Managed Through Web Interfaces Via Secure Encrypted Connection. 1.1.4. Features 1.1.4.1. Stateful Firewall 1.1.4.2. Ddos Prevention, Arp Spoofing Prevention 1.1.4.3. Anti-virus 1.1.4.4. Anti-malware, On-premise Artificial Intelligence Based Malware Detection Engine 1.1.4.5. Anti-phishing 1.1.4.6. Intrusion Prevention System 1.1.4.7. Web Application Firewall, Semantic Detection Method 1.1.4.8. Ssl Decryption 1.1.4.9. Risk Assessment By On-demand And Real-time Scanner 1.1.4.10. Cloud Sandboxing 1.1.4.11. Cloud Threat Intelligence 1.1.4.12. Ipsec Vpn 1.1.4.13. Ssl Vpn 1.1.4.14. User Authentication And Grouping 1.1.4.15. Web(url) Filtering, Application Control, Bandwidth Management 1.1.4.16. Report Center 1.1.4.17. The Proposed Solution Must Support Security Protection For Pre-attack, During-attack And Post-attack. 1.1.4.18. The Proposed Solution Must Support Security Protection For Business Systems And Network Users. 1.1.5. Firewall 1.1.5.1. The Proposed Solution Must Support Static And Dynamic Package Filtering, Inspection On Well-known Protocols Of Ftp, Http, Smtp, Rtsp, H.323 (q.931, H.245, Rtp/rtcp), Sqlnet, Nms, Pptp, Tcp, Udp 1.1.5.2. The Proposed Solution Must Be Able To Protect Against Attacks Of Land, Smurf, Fraggle, Winnuke, Ping Of Death, Tear Drop, Ip Spoofing, Syn/icmp/udp Flood, Http Get Flood, Dns Query Flood, Arp Cheating, Icmp Redirection, Static And Dynamic Black List, Etc 1.1.5.3. Geo-location Block, Create Rules To Allow Or Block Traffic From Ip Addresses In Specific Countries, Regions And States, Reduce The Attack Possible. 1.1.5.4. Supports Real-time Integration Status Between The Local Firewall And The Cloud-threat Intelligence But Not Limited By Providing: 1.1.5.4.1. The Total Number Of External Attack Events 1.1.5.4.2. The Total Number Of Threats Detected By Cloud Threat Intelligent In The Local Firewall 1.1.6. Intrusion Prevention System 1.1.6.1. The Proposed Solution Must Support Vulnerability Database With At Least 9000+ Entries 1.1.6.2. The Proposed Solution Must Support Separate Server And Endpoint Vulnerability Database Group For Convenient Policy Configuration 1.1.6.3. The Ips System Must Be Able To Block Worms, Trojans, Spyware, Scanning, Dos, Ddos, Vulnerability Exploits, Buffer Overflow Attacks, Abnormal Protocol And Attacks With Evasive Tactic Employed. 1.1.6.4. The Ips Supports Automatically Block, Logging, Upload Gray Threat To The "cloud" 1.1.6.5. The Ips Supports Burp-force Attack Prevention For Ftp, Imap Mssql, Pop3 Smtp, Oracle, Rdp, Smbv1, Smbv2, Smbv3 And So On. 1.1.7. Apt Prevention 1.1.7.1. The Proposed Solution Must Support Apt Detection Of Identifying Botnet, Remote Control Trojans, Malicious Link, And Other Threats. 1.1.7.2. The Proposed Solution Must Support Anti-malware Database With More Than 400,000+ Entries 1.1.7.3. The Proposed Solution Must Be Able To Conduct Cross-module Intelligent Correction Of Ips, Waf And Apt Detection Modules To Generate Temporary Fw Rules To Lock The Suspicious Ip When Malicious Behavior From That Ip Is Detected By Any Of The Modules. 1.1.7.4. Apt Supports Sandbox Dynamic Detection Via Security Cloud 1.1.7.5. Apt Supports To Detect Ddos Attack From Intranet 1.1.7.6. Apt Can Effectively Distinguish The Hazardous Traffic Flow In The Common Application Of The Rdp, Ssl, Imap, Smtp, Pop3, Ftp,, Dns,, Http, Web, And So On Traffic Flow , But Also Can Be Used For The Normal Operation Of Non-standard Port For Early Warning. 1.1.7.7. Support Honeypot Feature And Locate The Real Host Ip Address Of The Intranet Infected Botnet Virus 1.1.7.8. Support In-depth Analysis On Detected Malware Or Trojan Behaviors By Demonstrating Interaction & Communication Between External C&c Botnets And Other Suspicious Events. 1.1.8. Risk Assessment And Prevention 1.1.8.1. The Proposed Solution Must Provide Risk Assessment Module That Allows To Scan And Identify Security Loopholes Such As Open Port, System Vulnerabilities, Weak Passwords And Other Risks Of The Protected Servers 1.1.8.2. The Proposed Solution Must Support Real-time Vulnerability Analysis, Includes The Underlying Software Vulnerability Analysis, Web Application Risk Analysis, Web Unsafe Configuration Detection And Server Weak Password Detection, And Generate Real-time Analysis Reports. That Can Be Deployed In Mirror Mode To Discover System Vulnerabilities Within A Protected Network In Real-time. 1.1.8.3. The Real-time Vulnerability Is Also Supported To Detect For The Website If It Existed Backlink, And Can Record The Type Of The Black Link And The Location Of Backlink. 1.1.8.4. Risk Assessment And Scanning Results Must Be Shown And Generated With Corresponding Reports With Detailed Description Of The Issues And Recommended Solution. 1.1.8.5. Risk Assessment Module Must Be Able To Be Affiliated With The Ips And Server Protection Module To Automatically Generate The Protection Policies 1.1.8.6. Threat Alerts Is Able To Actively Push The Current Popular Zero Day Or High-risk Vulnerabilities, And Can Provide Vulnerability Detection Tools For Business Scan, According To The Results Of Scan, It Can Generate Safety Protection Policies. 1.1.9. Web Application Firewall 1.1.9.1. The Proposed Solution Should Come With Built-in Advanced Waf Capability In Firewall But Not Separate Appliance 1.1.9.2. The Proposed Solution Must Be Able To Defend Against The 10 Major Web-based Attacks Identified By The Open Web Application Security Project (owasp) , Including Sql Injection, Xss, Csrf, Etc., By Semantic Detection Engine. 1.1.9.3. The Proposed Solution Must Support Waf Database That Hosts Not Less Than 5000 Web-based Attacks Rules 1.1.9.4. The Proposed Solution Must Be Able To Perform Inspection Of The Content At The Perimeter For Incoming Traffic. Only To Allow Input Parameters That Conform To The Application Functionalities Required Of The Web Application And No Malicious Input Parameters 1.1.9.5. The Proposed Solution Must Be Able To Restrict Suspicious File Uploading With File Types Of Asp, Asa, Exe, Jsp, Php,aspx,php3,php4,phtml, Vbs Etc. 1.1.9.6. The Proposed Solution Must Support Application Hiding Of Http Error Pages Replacement, Http (s) Response Headers Hidden, And Ftp Server And Software Version Information Hidden, Etc. 1.1.9.7. Support Cc, Csrf And Cookie Attack Prevention. 1.1.9.8. Should Support Automatic On-demand Web Application Decoding 1.1.9.9. Support Password Protection, Including Ftp Weak Password Detection, Web Login Weak Password Detection, Web Login Plaintext Transmission Detection, Password Brute Force Protection 1.1.10. Anti-defacement 1.1.10.1. The Proposed Solution Must Support Server Access Verification For Administrator Website, Avoid Website Defacement 1.1.11. Data Breach Protection 1.1.11.1. Allow To Define Multiple Types Of Sensitive Information Based On The Characteristics Of Stored Data, The Sensitive Information Includes Email Account Information, Md5 Encrypted Passwords. 1.1.11.2. The Proposed Solution Must Be Able To Restrict Suspicious File Downloading With File Types Of Dat, Bak,dmp,backup, Asa,log, Fp, Frx, Frt, Cnf, Ade,mde, Db, Ldb,etc. 1.1.12. Anti-virus 1.1.12.1. Stream-based Antivirus For Http, Ftp, Smtp And Pop3 , Smbv3 Protocols, Etc. 1.1.12.2. The Proposed Solution Must Support Built-in Artificial Intelligence Capability To Detect Malware, Virus And Ransomware Variants And Provide The Malware Analysis Report 1.1.12.3. Should Support Compressed File Malware Inspection, Up To 16 Layer 1.1.12.4. Should Support Cloud Based Threat Intelligence And Analytics 1.1.13. Content Security 1.1.13.1. Mail Protect Support Pop3, Smtp, Imap, Pop3s, Smtps, Imaps And Other Specific Port. 1.1.13.2. Mail Protect Support Mail Collision Attack Prevention And Anti-phishing. 1.1.13.3. Mail Attachment Can Be Detected By Anti-virus. 1.1.13.4. Support Mail Attachment Filter And Http/ftp Download/upload Filter. 1.1.13.5. When Users Receive Malicious Mail, The Proposed Solution Will Tamper The Mail Subject 1.1.14. Access Management 1.1.14.1. The Proposed Solution Must Support Up To Eight User Identification Methods Such As Active Directory (ad) Authentication And Remote Authentication Dial-in User Service (radius) 1.1.14.2. The Proposed Solution Should Support Internet Application Identification Database With More Than 9000+ Entries And Url Database With More Than Hundreds Of Millions Entries That Updated With Cloud-based Technologies 1.1.14.3. The Proposed Solution Must Support Policy Configuration Oriented Toward Users And Applications For Web Filter, Application Control And Bandwidth Management 1.1.14.4. The Proposed Solution Must Support Security Policy Optimizer, Which Helps: 1.1.14.5. 1) Identify The Redundant Policy, Expired Policy, Conflict Policy Etc. 1.1.14.6. 2) Be Able To Track The Acl Policy Life Cycle, Help To Track Every Change That Have Been Done To The Policy In A Specific Period Of Time 1.1.14.7. The Proposed Solution Must Support Link Load Balance Per Traffic Load As Well As Application Type In Occasion Of Multiple Internet Lines 1.1.15. Reporting 1.1.15.1. The Proposed Solution Must Support Built-in Report Center, Which Provides Comprehensive Security Analyzing Reports Including But Not Limit To Attack Trends By “all Attacks” And “valid Attacks”; Security Rating By “business Server Security”, “user Security” And “vulnerability”; Business Server Security By Suffered Attack Times Ranking; Vulnerability Assessment 1.1.15.2. The Proposed Solution Must Support Business Model Learning, Which Will Help To Simplify The Security Operation For Web Servers, And Reduce The False Positives. 1.1.15.3. Support The Detailed Logs For Security Issues Such As Dos Attack, Web Attack, Ips, Viruses, Website Access, Application Control, User Login And Os Configuration. 1.1.15.4. Support Detailed Threats Analysis For Specific Attack By Description, Target, Solution; Support Security Analysis For Specific Server With Attack Type, Attack Source, Etc. 1.1.15.5. The Report Center Must Provide Full Visibility To Network, Endpoint Clients And The Business Servers With Multi-dimensional Analysis Of Risks, Vulnerabilities, Attacks, Threats, Traffic And Behaviors 1.1.15.6. Support Pdf Format And Automatically Send To Predefined Mailbox On Daily/weekly/monthly Basis 1.1.15.7. Supports Automatic Generation Of Comprehensive Security Risk Reports. The Content Of The Report Should Reflect But Not Limited: 1.1.15.7.1. The Overall Security Level Of The Protected Network Object 1.1.15.7.2. The Vulnerability Information & Forensic Evidence Each Attack 1.1.16. Deployment 1.1.16.1. Gateway (route Mode) 1.1.16.2. Bridge Mode 1.1.16.3. Mirror Mode 1.1.16.4. Multiple Bridge Mode(2- 4 Bridges 1.1.16.5. The Proposed Solution Must Support Build-in Auto Hardware Bypass In The Event Of Hardware Failure 1.1.16.6. Support Quick Deployment From Central Management Console 1.1.16.7. Must Be Compatible With The Existing Dhsud Network. 1.1.17. Vpn 1.1.17.1. The Proposed Solution Must Support To Build Proprietary Vpn Tunnel Between Hq And Branches 1.1.17.2. Ipsec Vpn 1.1.17.3. Authentication Algorithm: Md5/sha-1 1.1.17.4. Encryption Algorithm: Des/3des/aes128 Hash:md5/sha 1.1.17.5. Ssl Vpn 1.1.17.6. Source Type: L3vpn Resources, Tcp Resources. 1.1.17.7. Operating System Supported: Win Xp/win 7/win 8/win10/win11/mac 1.1.17.8. Supports 2fa With Google Authenticator, Microsoft Authenticator 1.1.18. Real-time Visibility 1.1.18.1. Real Time Provides Cpu, Memory, Disk Usage, Session Number, The Number Of Online Users, The Network Interface, Box Resource Information 1.1.18.2. The Proposed Solution Must Be Provided Real-time User Ranking / Real-time Application Ranking / Real-time Host Ranking 1.1.18.3. The Proposed Solution Must Provide Real-time Attack Map, Include Top Attack Country And Counting, Real-time Attacks And Threat Detail 1.1.18.4. Provide Information Security Incidents, Including Recently Security Incidents, Server Security Incidents, Terminal Security Incidents 1.1.18.5. In Security Status,it Displays The Current Network Risks That Need To Be Handled, And Top Attacks, Bots Show The Threat Stage And Security Rating. 1.1.18.6. Top Session Can Display Real-time, Last 24 Hours, Last 7 Days Of The Current Session And The New Session. 1.1.19. Routing 1.1.19.1. Supports Static Route, Ripv1 & V2, Ospfv2 And Bgp 1.1.19.2. The Proposed Solution Must Be Able To Support But Not Limited To Intelligent Route Selection Based On Source And Destination Ip, Port, Protocol And Country-based Ip Address 1.1.19.3. Support Dns-mapping 1.1.19.4. Support Custom Intranet Dns Server Address To Avoid Botnet Detection Misjudgment Dns Server 1.1.20. Certification 1.1.20.1. The Proposed Solution Must Be Certified By Icsa Labs. 1.1.20.2. The Proposed Solution Must Have Aaa Rating At Cyberratings Enterprise Firewall. 1.1.20.3. The Proposed Solution Must Be In Visionaries Or Higher Level Of Gartner Magic Quadrant For Network Firewalls 2021 1.1.20.4. The Proposed Solution Must Be Cmmi L5 Certified. 1.1.20.5. Iso 9001:2015 1.1.20.6. Iso/iec 27001:2013 1.1.20.7. The Project Implementer Must Be Cissp Certified. 1.2. Scope Of Works 1.2.1.1. Diagnosis And Resolution Of Problems On The Performance Deficiencies Of The Software/firmware/licenses. 1.2.1.2. Provide Product Patches, Updates, Releases, And New Versions Of The Software/firmware/licenses 1.2.1.3. Health Check Of Firewall Appliance On A Regular Basis (at Least Once A Month) 1.2.1.4. Health Checks, Repair Or Replacement Of Defective/malfunctioning Hardware Parts During The Lease Period. 1.2.1.5. The Service Provider Shall Provide 24/7 Technical Personnel In Close Coordination With The End User. B. Deliverables I. Three (3) Months Of Support During The Lease Period C. Duration Of The Contract I. The Overall Duration Of The Contract Is One Hundred (90) Calendar Days For The Supply, Delivery, Installation, Configuration, And Training With Provision For Extension. While The Necessary Services Are Required To Be Provided For Three (3) Months After Implementation. D. Service Support Requirements I. The Prospective Bidder Must Have A Team Of Certified Engineers For The Installation And Configuration For Local Deployment Using The Offered Solution. The Bidder Must Provide Copies Of Certificates From The Manufacturer That Engineers Are Certified/qualified To Install And Configure The System. Ii. The Prospective Bidder Must Provide Maintenance Services Thru Corrective/remedial Maintenance And Quarterly Health Checks During The Duration Of The Contract. Iii. The Prospective Bidder Must Ensure Service Units Are Readily Available During Down-time During The Contract Period. Service Units Should Be Delivered On-site Next Business Day When The Hardware Cannot Be Repaired On Site Due To Failure, Within Metro Manila. Iv. The Principal Manufacturer Must Provide Unlimited E-mail Submission And Telephone Access 24x7. Prospective Bidder Must Provide Procedures Support And Problem Escalation, Technical Phone Support 24x7; Response Time Must Be Within Four (4) Hours Upon Receipt Of Notification From Dhsud End-user/designated Personnel. E. Minimum Requirements For Bidders: I. Valid And Current Certificate Of Distributorship/resellership/dealership Issued By Manufacturer. If The Certificate Is Not Issued By The Manufacturer, The Bidder Must Also Present An Appropriate Document Showing The Relationship Between The Manufacturer And The Issuing Company. 5. Acceptance/testing Criteria And Process A. User Acceptance I. Proposed Product Must Conform With The Technical Specifications And Schedule Of Requirements. 6. Payment Terms And Schedule Activities/milestone Duration % Progress Health Check, Inspection And Acceptance Of Next Generation Firewall Within 15 Days From Notice To Proceed 10% Of The Contract Price Monthly Leasing Of Next Generation Application Firewall Monthly Payment For Three (3) Months After The Conduct Of Successful Training And Submission Of Complete Documentation 90% Of The Contract Price 7. Timelines For The Implementation Of The Project A. Delivery Schedule Item Delivery Date Health Check, Inspection And Acceptance With Technical Report/s Within Fifteen (15) Calendar Days From Receipt Of Notice To Proceed. Knowledge Transfer For At Least Six (6) Dhsud Personnel Submission Of Complete Project Documentation. Within Fifteen (15) Calendar Days From Receipt Of Notice To Proceed. Three (3) Months Of Lease, Services And Support Will Commence After Project Implementationterms And Conditions: 1. Payment Shall Be Made Upon Completion Of Service/delivery And Submission Of The Supporting Documents (e.g., Delivery Receipt, Sales Invoice, Billing Statement, Warranty Certificate If Applicable, And Other Documents As May Be Required In The Technical Specifications); 2. Kindly Accomplish The Attached Reply Slip Correctly And Accurately. Please Do Not Alter The Contents Of The Form In Any Way; 3. All Technical Specifications Are Mandatory. Failure To Comply With Any Of The Said Requirements Shall Be A Cause For The Disqualification Of Your Quotation; 4. The Department Shall Have The Right To Inspect The Goods To Check Its Conformity With The Required Minimum Technical Specifications; 5. Issuance Of Official Receipts (or) Or Sales Invoice (si) In The Name Of The Department Of Human Settlements And Urban Development (dhsud) Is Mandatory. The Supplier Shall Bear The Cost Of Mailing The Ors Or Sis. The Supplier Shall Be Responsible For Bearing Any Bank Charges And/or Service Charges That May Be Incurred By The Department In Case Of Payment Requests Via Check Deposit; 6. Please Submit The Latest Copy Or E-copy Of The Following Documentary Requirements: A. Philgeps Registration Number / Certificate Of Philgeps Membership; B. 2024 Mayor’s Permit/business Permit; (note: In Case The Permit Has Recently Expired, Please Submit The Old Permit And Attach The Official Receipt For The Renewal Application Thereof.) C. Signed Omnibus Sworn Statement (oss); Note: A Notarized Omnibus Sworn Statement (oss) Shall Be Submitted By The Lcrb Or Scrb Prior To The Processing Of Payment. If The Authorized Representative Listed On The Reply Slip Is Not The Same Person Who Executed The Omnibus Sworn Statement (oss) Kindly Attach A Copy Of The Notarized Special Power Of Attorney (spa) Together With The Valid Government-issued Identification Card Of Both Signatories. D. Supporting Documents (as May Be Applicable): For Sole Proprietorships – Dti Business Name Registration; For Partnerships Or Corporations - A Notarized Special Power Of Attorney, Or A Notarized Secretary’s Certificate, Whichever Is Applicable (bidders With Previously Submitted Eligibility Requirements, Provided They Are Current And Updated, Are No Longer Required To Submit The Said Documents.) Your Quotation Or Bid Proposal Must Be Submitted Together With The Attached Reply Slip And The Above Mentioned Documentary Requirements Through Personal Delivery, And In A Sealed Envelope, To The Procurement Division Located At The 8th Floor, Dhsud Building, Kalayaan Avenue Corner Mayaman Street, Diliman, Quezon City, Or Through Electronic Mail At Procurement@dhsud.gov.ph. The Dhsud Bids And Awards Committee (bac), Through The Concerned End-user Unit And The Bac Secretariat, Shall Recommend The Award Of The Contract To The Head Of The End-user Unit Or Implementing Office, Of The Service Provider With The Single/lowest Calculated And Responsive Quotation Slrq/(lcrq) Pursuant To Section 53.10 Of The 2016 Revised Irr Of Ra 9184. With The End View Of Obtaining The Contract Most Advantageous To The Government Pursuant To Sec. 41 Of The 2016 Revised Irr Of Ra 9184, Dhsud Reserves The Right To Reject Any And All Quotations/bids, To Annul The Procurement Process, To Declare A Failure Of Bidding, To Reject All Quotations/bids At Any Time Prior To Contract Award, Or Not To Award The Contract, Without Thereby Incurring Any Liability To The Affected Bidder/s. For Questions And/or Clarifications, Please Contact The Procurement Division At Telephone Number 8424-4080 (local 1833). (original Signed) Anilaine L. Gamba Oic, Procurement Division Reply Slip Procurement: Lease Of Ngfw Firewall For Dhsud For 3 Months (1st Rebidding) Request For Quotation No.: 02-0057, S. 2024 _______________ Date Anilaine L. Gamba Oic-procurement Division Department Of Human Settlements And Urban Development 8th Floor, Administrative Services Dhsud Bldg. Kalayaan Avenue, Cor. Mayaman St. Quezon City Dear Ms. Gamba: This Is To Submit The Following Bid Quotation/proposal For The Subject Procurement With A Total Bid Price Of __________________________________ Pesos (php________.00), Inclusive Of All Existing And Appropriate Government Taxes And Charges: Quantity Unit Description I Hereby Certify That The Above Bid Quotation/proposal Is True And Correct, And I Accept The Rights Of The Department Of Human Settlements And Urban Development, As The Procuring Entity, Under Section 41 Of The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Thank You. Truly Yours, Name Of Company: ____________________________________________ Name Of Authorized Representative: _______________________________ Designation/position: ____________________________________________ Address: _____________________________________________________ Telephone No./mobile No.: _______________________________________ Email Address: ________________________________________________ Philgeps Registration No. : ______________________________________ Landbank Account No.: _________________________________________ If With Ada, Kindly Indicate The Landbank Account Name And Account Number; If None, Please Indicate To Whom Checks Should Be Made Payable To : _____________________________________ Tin: __________________________ Vat-registered: Vat󠄀 ( ) Non-vat ( ) Signature: ____________________________________________________ Omnibus Sworn Statement (revised) [shall Be Submitted With The Bid] [kindly Fill Out This Template Accordingly By Completing The Needed Information And Deleting The Non-applicable Provisions That May Be Deleted.] _________________________________________________________________________ Republic Of The Philippines ) City/municipality Of ______ ) S.s. Affidavit I, [name Of Affiant], Of Legal Age, [civil Status], [nationality], And Residing At [address Of Affiant], After Having Been Duly Sworn In Accordance With Law, Do Hereby Depose And State That: 1. [select One, Delete The Other:] [if A Sole Proprietorship:] I Am The Sole Proprietor Or Authorized Representative Of [name Of Bidder] With Office Address At [address Of Bidder]; [if A Partnership, Corporation, Cooperative, Or Joint Venture:] I Am The Duly Authorized And Designated Representative Of [name Of Bidder] With Office Address At [address Of Bidder]; 2. [select One, Delete The Other:] [if A Sole Proprietorship:] As The Owner And Sole Proprietor, Or Authorized Representative Of [name Of Bidder], I Have Full Power And Authority To Do, Execute And Perform Any And All Acts Necessary To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract For [name Of The Project] Of The [name Of The Procuring Entity], As Shown In The Attached Duly Notarized Special Power Of Attorney; [if A Partnership, Corporation, Cooperative, Or Joint Venture:] I Am Granted Full Power And Authority To Do, Execute And Perform Any And All Acts Necessary To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract For [name Of The Project] Of The [name Of The Procuring Entity], As Shown In The Attached [state Title Of Attached Document Showing Proof Of Authorization (e.g., Duly Notarized Secretary’s Certificate, Board/partnership Resolution, Or Special Power Of Attorney, Whichever Is Applicable;)]; 3. [name Of Bidder] Is Not “blacklisted” Or Barred From Bidding By The Government Of The Philippines Or Any Of Its Agencies, Offices, Corporations, Or Local Government Units, Foreign Government/foreign Or International Financing Institution Whose Blacklisting Rules Have Been Recognized By The Government Procurement Policy Board, By Itself Or By Relation, Membership, Association, Affiliation, Or Controlling Interest With Another Blacklisted Person Or Entity As Defined And Provided For In The Uniform Guidelines On Blacklisting; 4. Each Of The Documents Submitted In Satisfaction Of The Bidding Requirements Is An Authentic Copy Of The Original, Complete, And All Statements And Information Provided Therein Are True And Correct; 5. [name Of Bidder] Is Authorizing The Head Of The Procuring Entity Or Its Duly Authorized Representative(s) To Verify All The Documents Submitted; 6. [select One, Delete The Rest:] [if A Sole Proprietorship:] The Owner Or Sole Proprietor Is Not Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; [if A Partnership Or Cooperative:] None Of The Officers And Members Of [name Of Bidder] Is Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; [if A Corporation Or Joint Venture:] None Of The Officers, Directors, And Controlling Stockholders Of [name Of Bidder] Is Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; 7. [name Of Bidder] Complies With Existing Labor Laws And Standards; And 8. [name Of Bidder] Is Aware Of And Has Undertaken The Responsibilities As A Bidder In Compliance With The Philippine Bidding Documents, Which Includes: A. Carefully Examining All Of The Bidding Documents; B. Acknowledging All Conditions, Local Or Otherwise, Affecting The Implementation Of The Contract; C. Making An Estimate Of The Facilities Available And Needed For The Contract To Be Bid, If Any; And D. Inquiring Or Securing Supplemental/bid Bulletin(s) Issued For The [name Of The Project]. 9. [name Of Bidder] Did Not Give Or Pay Directly Or Indirectly, Any Commission, Amount, Fee, Or Any Form Of Consideration, Pecuniary Or Otherwise, To Any Person Or Official, Personnel Or Representative Of The Government In Relation To Any Procurement Project Or Activity. 10. In Case Advance Payment Was Made Or Given, Failure To Perform Or Deliver Any Of The Obligations And Undertakings In The Contract Shall Be Sufficient Grounds To Constitute Criminal Liability For Swindling (estafa) Or The Commission Of Fraud With Unfaithfulness Or Abuse Of Confidence Through Misappropriating Or Converting Any Payment Received By A Person Or Entity Under An Obligation Involving The Duty To Deliver Certain Goods Or Services, To The Prejudice Of The Public And The Government Of The Philippines Pursuant To Article 315 Of Act No. 3815 S. 1930, As Amended, Or The Revised Penal Code. In Witness Whereof, I Have Hereunto Set My Hand This __ Day Of ___, 20__ At ____________, Philippines. [insert Name Of Bidder Or Its Authorized Representative] [insert Signatory’s Legal Capacity] Affiant [jurat] [format Shall Be Based On The Latest Rules On Notarial Practice]
Closing Date26 Feb 2024
Tender AmountPHP 295 K (USD 5.2 K)
Municipality Of Los Ba os, Laguna Tender
Furnitures and Fixtures
Corrigendum : Tender Amount Updated
Philippines
Details: Description Mswdo (p 55,000.00) Printer 2 Unit Type: Print, Scan, Copy Photo Default - 10 X 15 Cm / 4 X 6"; Approx. 69 Sec Per Photo (border) / 90 Sec Per Photo (borderless) *1 Draft; A4 (black / Colour); Up To 33 Ppm / 15 Ppm*1 Iso 24734, A4 Simplex (black / Colour); Up To Ipm / 5.0 Ipm *1 First Page Out Time From Ready Mode (black / Colour); Approx. 10 Sec / 16 Sec *1 Copy Quality: Colour / Black And White; Draft / Standard Maximum Copies From Standalone: 20 Copies Maximum Copy Size: A4 , Letter Iso 29183, A4 Simplex Flatbed (black / Colour); Up To 7.0ipm / 1.7 Ipm Max Copy Resolution: 300 X 300 Dpi Scanner Type: Flatbed Colour Image Scanner Optical Resolution: 600 X 1200 Dpi Maximum Paper Size: 215.9 X 1200 Mm (8.5 X 47.24") Output Capacity: Up To 30 Sheets, A4 Plain Paper 20 Sheets, Premium Glossy Photo Paper Dimensions (w X D X H); 375 X 347 X 179 Mm Weight: 3.9kg Consumables: Black Ink Bottle: 4,500 Pages *4 - 003 Cyan Ink Bottle: 7,500 (composite Yield) *4 - 003 Magenta Ink Bottle: 7,500 (composite Yield)*4 - 003 Yellow Ink Bottle: 7,500 (composite Yield) *4 - 003 Printing Technology: On-demand Inkject (piezoelectric) Nozzle Configuration: 180 X 1 Nozzes Black, 59 X 1 Nozzles Per Colour (cyan, Magenta, Yellow) Operating System Compability; Windows Xp / Vista / 7 / 8 / 8.1 / 10 Windows Server 2003 / 2008 / 2012 / 2016 Only Printing And Scanning Functions Are Nsupported For Windows Server Os Mac Os X 10.0 Or Later 1 Year Warranty Flatbed Scanner 1 Unit A4 Flatbed Colour Image Scanner Cis Sensor Led Light Source 1,200 X 1,200 Dpi Optical Resolution 50 - 1,200 Dpi Output Resolution 30-bit Input, 24 Bit Output (colour) 10-bit Input, N8bit Output (grayscale) 10-bit Input, 1 Bit Output (black And White) 216 X 297 Mm Max Document Size Output File Formats: Jpeg, Tiff, Multi-tiff, Pdf, Searchable, Pdf, Bmp,m Png Scan Speed: Fl;atbed (black/colour) 200 Dpi: 6.0 Sec / 7.0 Sec 300 Dpi: 6.0 Sec / 7.0 Sec 600 Dpi: 14 Sec / 26 Sec Adf Monochrome (simplex / Duplex) 200 Dpi: 25 Ppm / 10 Pm 300 Dpi: 25 Ppm / 10 Pm 600 Dpi: 10 Ppm / 6.0 Pm Adf Colour (simplex / Duplex) 200 Dpi: 25 Ppm / 10 Pm 300 Dpi: 25 Ppm / 10 Pm 600 Dpi:: 10 Ppm / 6.0 Pm 1 Year Warranty Bac (p 36,000.00) All -in-one Inkjet, Colour, Duplex, Wi-fi Printer 1 Unit With Integrated Ink Tank System And Automatic Document Feeder Interface: Usb: Usb 2.0 Network: Ethermet, Wifi Ieee, 11b/g/n, Wifi Direct Lcd Screen: Colour Lcd Print Printing Technology: On-demand Inkject (piezoelectric) Nozzle Nconfiguratio: 400 X 1 Nozzles Black, 128 X 1 Per Colour (cyan, Magenta, Yellow) Print Direction: Bi-directional Printing Maximum Print Resolution: 4800 X 1200n Dpi Print Speed: Draft, A4 (black / Colour): Up To 33 Ppm / 20ppm Iso 24734, A4 Simplex (black / Colour): Up To 15.5 Ipm / 8.5 Ipm Copy Copy Quality: Colour / Black-and-white; Draft / Stsndsrd Maximum Copies: From Standalone ; 99 Copiew Maximum Copy Size: A4, Letter Mamax Copy Resolution: 600 X 600 Dpi Maximum Copy Size: Legal Iso 29183, A4 Flatbed (black / Colour): Up To 11.0 Ipm / 5.5 Ipm Scan Scanner Type: Flatbed Colour Image Scanner Optical Resolution: 1200 X 2400 Dpi Flatbed (black / Colour); 200 Dpi: 12 Sec / 200 Dpi 29 Sec Adf Support Paper Thickness: 64 - 95 G/m2 Paper Capacity: 30 Pages (a4), 10 Pages (legal) Sec Dimensions (w X D X H); 375 X 347 X 237 Mm Weight: 6.7 Kg With 1 Year Warranty Uninterruptible Power Supply (ups) 2 Unit Power Rating: 650va Voltage Range: 140-290v Frequency: 50/60hz + 5% Voltage (inverter Mode): 20v + 10% Capacity: 50/60/hz + 1% Maximum Wattage: 390 Watts No. Of Sockets Back-up & 4 Socket Surge Protection Over Load/short Circuit: Current Limit For Both Main & Battery Modes Warranty: One (1) Year On Parts And Services Mpoc (p 15,000.00) All Inkjet Color Printer Ink Tank System 1 Unit Interface: Usb: Usb 2.0 Print: Printing Technology: On-demand Inkjet (piezoelectric) Nozzle Configuration: 180 X 1 Nozzles Black, 59 X 1 Nozzles Per Colour (cyan, Magenta,yellow) Print Direction- Bi-directional Printing Maximum Print Resolution: 5760 X 1440 Dpi (with Variable Droplet Technology) Print Speed: Draft, A4 (black / Colour): Up To 33 Ppm / 15 Ppm Iso 24734, A4 Simplex (black / Colour): Up To 10ipm / 5.0ipm Copy: Copy Quality: Colour / Black -and- White3: Draft / Standerd Maximum Copies Fom Standalone: 20 Copies Maximum Copy Size: A4, Letter Max Copy Resolution: 300 X 300 Dpi Scan: Scanner Type: Flatbed Colour Image Scanner Optical Resolution: 600 X 1200 Dpi Maximum Scan Area: 216 X 297 Mm (8.5n X 11.7") Flatbed (black / Colour); 200 Dpi; 11 Sec / 200 Dpi; 32 Sec Dimensions (w X D X H); 375 X 347 X 179 Mm Weight: 3.9 Kg 1year Warranty Tourism (p 15,000.00) All-in-one Inkjet Color Printer With Integrated Ink Tank System 1 Unit Print: Printing Technology; On-demand Inkjet (piezoelectric) Nozzle Configuration; 180 X 1 Nozzles Lack, 59 X 1 Nozzles Per Colour (cyan, Magenta, Yellow) Print Direction; Bi-directional Printing, Maximum Print Resolution: 5670 X 1440 Dpi (with Variable-sized Droplet Technology) Print Speed; Draft, A4 (black / Colour(; Up To 10ipm / 5.0ipm Copy: Copy Quality: Colour / Black-and- White; Draft/ Standard; Maximum Copies From Standalone; 20 Copies, Maximum Copy Size: A4, Letter Max Copy Resolution; 300 X 300 Dpi Scan: Scanner Type; Flatbed Colour Imageb Scanner Optical Nresolution: 600 X 1200 Dpi, Maximum Scan Area, 216 X 297 Mm ( 8.5 X 11.7") Flatbed (black / Colour); 200 Dpi; 11 Sec / 200 Dpi: 32 Sec, Dimensions (w X D X H); 375 X 347 X 179 Mm; 3.9 Kg 1 Year Warranty Mdrrmo (p 88,500.00) Heavy Duty Laminating Machine Laminator With 1 Unit Fan 260 Mm Photo Laminator Hot And Cold Mounted Size 260 Mm Type: Heavy Duty Speed: 0.5/ Min. Maximum Rubber Width: ≤260mm Maximum Glu Thickness: ≤2mm Gel Temperature: 100 -180°c Number Of Rubber Rollers: 4 Heating Method: Infrared Heating Power: 520w Wi-fi Printer With Integrated Ink Tank System And 1 Unit Automatic Document Feeder Usb: Usb 2.0 Network: Ethemet, Wifiieee 802.iib/g/n, Wifi Direct · Print Nozzle Nconfiguration: 180 X 1 Nozzles Black, 59x 1 Nozzles Per Colour (cyan, Magenta, Yellow) Print Direction: Bi-directional Printing Maximum Print Resolution; 5760 X 1440 Dpi (with Variable Sized Drolet Technology) Print Speed: Draft,a4 (black / Colour) Up To I0ipm / 5.0 Ipm · Copy Copy Quality: Colour / Black-and White Draft Standard Maximum Copies From Standalone: 99copies Max Copy Resolution: 600 X 600 Dpi Maximum Copy Size: Legal Iso 29183, A4 Flatbed (black / Colour); Up To 7.7 Ipm / 3.8 Ipm · Scan Scanner Type: Flatbed Colour Image Scanner Optical Resolution: 1200 X 2400 Dpi Flatbed (black / Colour) 200 Dpi 12 Sec / 200 Dpi: 29 Sec · Adf Support Paper Thickness: 64 - 95 G/m2 Paper Capacity: 30 Pages (a4) 10 Paes (legal) Sec Dimensions (w X D X H: 375 X 347 X 237 Mm Weight: 5 Kg, 1 Year Warranty Color, Duplex, Wi-fi Printer With Integrated Ink Tank 2 Unit System And Automatic Document Feeder Usb: Usb 2.0 Network: Ethemet, Wifi Ieee 802.iib/g/n Wifi Direst Lcd Screen: 2.4" Colour Lcd · Print Nozzle Configuration: 400 X 1 Nnozzles Black, 128 X 1 Per -colour (cyan,magenta,yellow) Print Direction: Bi-directional Printing Maximum Print Resolution: 4800 X 1200 Dpi Print Speed: Draft, A4 (black / Colour); Up To 33 Ppm / 20 Ppm Iso N24 734, A4 Simplex (black / Colour); Up To15.5 Ipm / 8.5 Ipm · Copy Copy Quality: Colour / Black-and-white; Draft/ Standard Maximum Copies From Standalone: 99copies Maximum Copy Size: A4, Letter Max Copy Resolution; 600 X 600 Dpi Maximum Copy Size: Legal Iso 29183, A4 Flatbed (black/ Colour); Up To 11.0 Ipm / 5.5 Ipm · Scan Scanner Type: Flatbed Colour Image Scanner Optical Resolution: 1200 X 2400 Dpi Flatbed (black / Colour); 200 Dpi; 12 Sec/200 Dpi: 29sec · Adf Support Paper Thickness: 64 - 95 _g/m2 Paper Capacity: 30 Pages (a4), 10 Pages (legal) Sec Dimensions (w X D X H); 375 X 347 X 237 Mm Weight: 6.7 Kg 1 Year Warranty External Hard Drive (1tb) 1 Unit !tb Hard Drive High Speed External Hard Drive Form Factor: 2.5 Inches Interface: Usb 3.0 Data Transfer Rate: 120 Mb/s Os Support: Windows 7/ 8/10 Mac Os X 10.7 Or Higher Pdao (p 17,000.00) Printer 1 Unit Printer Type Print, Scan, Copy, Fax With Adf Maximum Resolution 5760 X 1440 Dpi Maximum Copies From Standalone 99 Copies Reduction / Enlargement 25 - 400% Maximum Copy Resolution 600 X 600 Dpi Maximum Copy Size Legal Scanner Type Flatbed Colour Image Scanner Up To 100 Sheets Of Plain Paper (80 G/m2) Up To 20 Sheets Of Premium Glossy Photo Paper Up To 30 Sheets Of Plain Paper (80 G/m2) Up To 20 Sheets Prmium Glossy Photo Paper Lcd Screen 1,44 " Colour Lcd Ethemet; Wifi Ieee 802,. 11b/g/n, Wifi Direct Photo Default - 10 X 15 Cm / 4 X 6 &qout; *1 Approx. 69 Sec Per Photo (border) / 90 Sec Per Photo (boderless) *2 Draft, A4 (black / Colour ) Up To 33 Ppm / 15 Ppm*2 Iso 24734, A4 Simplex ( Simplex (black / Colour) Up To 10ipm / 5.0'ipm*2 First Page Out Time From Ready Mode (black / Colour) Approx. 10 Sec / 16*2 (one Year Warranty Pio (p 79,000.00) Gimbal - Color: Black, Item Dimensions: (lxwxh) 7.28 X 7.95 X 19.13 1 Pc Inches, Item Weight: 1850 Grams, Maximum Weight: Recommendation 8 Pounds, 360-degree Rotation Capability, Compatibilty With Most Mirroress Cameras And Dslrs, Joystick For Precision Panning And Tilting, 1 Yr Warranty 16tb External Hard Drive Hdd 1 Pc Usb 3.0, With Rescue Data Recovery Services (stkp16000402) Easy - To - Use Desktop Hard Drive - Simply Plug In The Power Adapter And Usb Cable Fast File Transfers With Usb 3.0 Drag- And Drop File Saviong Right Out Of The Box Automatic Recognition Of Windows And Mac Computers For Simple Setup ( Reformatting Required For Use With Time Machione) Product Dimensions: 3.03 X 8.35 X 8.58 In Ches, 2.59 Pounds Camera Lens - Ef50mm F/1.8 Series Standard Lens, The Ef50mm 1 Pc F/1.8 Stm, Which Has A Body That Includes A Metallic Mount, Makes Use Of A Stepping Motor (stm) That Ensures Silent, Speedy Autofocus Drive Operation. The Lens Construction, Consisting Of 6 Elements In 5 Groups And 7-blade Circular Aperture, Has Optimized Lens Coatings That Suppress The Occurance Of Flare And Ghosting, Resulting In High Image Quality With Its Lightweight, Compact Design That Belies A Surprisingly Large Diameter, This Lens Is Convenient And Easy Touse For Any Scene, And Allows For Effortless Taking Of Photos With A Large, Beautiful Background Blur. Max Aperture: F/1.8 With Stm Motor Filter Size: 49mm Gad (p 112,000.00) Paper Shredder 1 Unit 23l Paper Shredder 12 Sheets Level 4 Confidentiality Electric Silent Office Document Shredder Can Shred Cd, Dvd, Paper Card, Paper Clip Stape For 10 Minutes White Color One (1) Year Warranty Printer 3 Unit All-in-one Inkjet, Color, Dup[lex, Wifi Printer With Integrated Ink Tank System And Automatic Feeder Interface Usb: Usb 2.0 Network: Ethemet, Wi-fi Ieee 802.11b/g/n, Wi-fi Direct Lcd Screen; 2.4" Colour Lcd Print Printing Technology: On-demand Inkjet (piezoelectric) Nozzle Configuration: 400 X 1n Nozzless Mblack, 128x1 Per Colour (cyan, Magenta, Yellow) Print Speed: Draft, A4 (black/colour): Up To 33 Ppm/20ppm Iso 24734, A4 Simplex (black/ Colour): Up To 15.5 Ipm/8.5ipm Copy Copy Quality: Colour: Colour/ Black-and -white Draft/ Standard Maximum Copies From Standalone: 99 Copies Maximum Copy Size: A4, Letter Max Copy Size: Legal Iso 29183, A4 Flatbed (black/colour): Up To 11.0 Ipm/5.5 Ipm Scan Scanner Type: Flatbed Colour Image Scanner Optical Resolution: 1200 X 2400 Dpi Flatbed (black/ Colour): 200 Dpi: 12 Sec/200 Dpi: 29 Sec Adf Support Paper Thicknes: 64-95 G/m2 Paper Capacity: 30 Pages (a4), 10 Pages (legal) Sec Dimensions (w X D X H): 375 X 347 X 237 Mm Weight: 6.7 Mkg One (1) Year Warranty Uninterruptible Power Supply (ups) 5 Unit Output Power Capaity: 550watts/1.1kva Max Configirable Power (watts)/1.1kva Normal Output Voltage: 230v Output Frequency: 50/60hz -/-1 Hz Topolgy: Line Interactive Wave From Tyoe: Stepped Approximation To Sinewave Output Connections: (2) Iec320 C13 (battery Backup) Transfer Time: 4ms Typical: 6ms Maximum Nominal Input Voltage: 230v Input Frequency: 50/60hz +/-3hz (auto Sensing) Input Connection: Iec-320 C14, Nema 5-15p Cord Length:1.22 Meteers, Input Power Factor At Full Load: 0.5 Input Voltage Range For Main Operations: 150-280 Volts Number Of Power Cords: 1, Maximum Input Current: 10.0a Type Input Protection Required: 3-pole Breaker One (1) Year Warranty Peso (p 100,000.00) Printer 3 Unit Description All In One Inkject, Color Duplex, Wi-fi Printer With Integrated Ink Tank System And Automatic Document Feeder *interface: Usb: Usb 2.0 Network: Ethernet, Wi-fi Ieee 802, 11b/g/n Wi-fi Direct Lcd Screen: 2.4" Colour Lcd *print Printing Technology: On-demand Inkjet (piezoelectric) Nozzle Configuration: 400 X 1 Nozzles Blsck, M120 X 1 Per Colour (cyan, Magenta, Yellow) Print Direction: Bi-directioning Printing Maximum Print Resolution: 4800 X 1200 Dpi Print Speed: Draft, A4 (black/colour): Up To 33 Ppm/20 Ppm Iso 24734, A4 Simplex (black/colour): Up To 15.5 Ipm/8.5 Ipm *copy: Copy Quality: Colour/black-and-white, Draft/ Standard Maximum Copies Fromn Stand Alone: 99 Copies Maximum Copy Resolution: 600 X 600 Dpi Maximum Copy Size: Iso 29183, A4 Flatbed (black/ Colour *scan: Scanne Type: Flatbed Colour Image Scanner Optical Resolutionj Flatbed (black/colour): 200 Dpi: 20 Sec. *adf Support Paper Thickness: 64-95 G/m2 Paper Capacity: 30 Pages (a4), 10 Pages (legal) Sec Dimensions (w X D X H); 375 X 347 X 237 Weight: 6.7 Kg 1 Year Warranty Printer 2 Unit Description: All In One Inkject, Color Duplex, Wi-fi Printer With Integrated Ink *interface: Usb: Usb 2.0 *print: Printing Technology: On-demand Iinkjet (piezoelectric) Nozzle Configuration: 180 X 1nozzles Black, 59 X 1 Nozzles Per Colour (cyan,magenta, Yellow) Print Direction: Bi-directional Printing Maximum Print Resolution: 5760 X 1440 Dpi (with Variable- Droplet Technology) Print Spoeed: Draft, A4 (black/colou); Up To 33 Ppm/15 Ipm *copy: Copy Quality; Colour/black-and-white, Draft/ Standard Maximum Copies From Stand Alone: 20 Copies Maximum Copy Size: A4 Letter Maximum Copy Resolution: 300 X 300 Dpi *scan Scanner Type: Flatbed Colour Image Scanner Optical Resolution: 600 X 1200 Dpi Maximum Scan Area: 216 X 297 Mm (8.5 X 11.7") Flatbed (black/colour): 200 Dpi; 11 Sec/ 200 Dpi: 32 Sec Dimensions (w X D X H); 375 X 347 X 179 Mm Weight : 309 Kg 1 Year Warranty Mho (p 30,000.00) Document Scanner 1 Pc Scanner Type; A4 Flatbed Colour Image Scanner Sensor : Cislight Source; Led Optical Resolution; 1,200 X 1,200 Dpi Output Resolution; 50 - 1,200 Dpi (in 1 Dpi Increments) Scanner Bit Depth (colour); 30-bit Input, 24-bit Output Scanner Bit Depth (grayscale); 10-bit Input, 8-bit Output Scanner Bit Depth (black & White); 10-bit Input, 1-bit Output Max Document Size: 216 X 297 Mm Output File Formats: Epson Scan 2: Jpeg, Tiff, Multi-tiff,pdf, Searchable Pdf,bmp, Png Document Capture Pro (win); Jpeg, Bmp, Pdf, Searchable Pdf, Tiff, Multi-tiff, Png, Docxz, Xlsx, Pptx Scan Speed: Flatbed (black / Colour); 200 Dpi; 6.0 Sec / 7.0 Sec 300 Dpi; 6.0 Sec / 7.0 Sec 600dpi: 14 Sec / 26 Sec Adf Monochrome (simplex / Duplex): 200 Dpi; 25ppm / 10ipm 300 Dpi; 25 Ppm / 10ipm 600 Dpi: 10ppm / 6.0ipm Adf Specifications: Scanner Type: A4 Sheet-fed, 3-pass Duplex Scanner Optical Sensor: Cis Light Source: Rgb Led Optical Resolution: 600 Dpi X 600 Dpi Output Resolution: 50 - 1,200 Dpi (in 1 Dpi Increments) Min Document Size: 89 X 127 Mm (simplex), 89 X 170 Mm (duplex) Max Document Size: 215.9 X 3,048 Mm Support Paper Thickness: 50 Gsm - 120 Gsm Adf Capacity: 50 Sheets Automatic Duplex Scanning : Yes (3-pass) Daily Duty Cycle: Up To 1,500 Pages / Day One Year Warranty Treasury (p 55,000.00) 24-pin Narrow Carriage Impact Printer 1 Unit Printing Technology Print Method Impact Dot Matrix Numbeer Of Pins In Head Print Dii Print Direction Control Code Print Speed High Speed High Speed Draft 10/12 Cpi Draft 10/12/15 Cpi Draft Condensed 17/20cpi Lq 10/12/15 Cpi Lq Condensed 17/20 Cpi Pitch 10/12/15/17/20 Cpi Tractor Rear In Top Out Manual Insertion Rear In, Top Out Reliability Mean Print Nvolume Between Failure Approx 20 Millions Lines (except Pint Head) Mean Time Between Failure Approx 10,000 Poh (25% Duty) Print Head Life Approx 400 Million Stroke / Wire Control Panel 4 Switches And 5 Leds Money Counter 1 Unit Money Counter Machine With Detector Original Money Detector For Fake Bill With External Led Display Printing Calculator 2 Unit Product Features: Line Printing 2 Color Prpri 2 Color Print, Reprint/ After Print Function Adding Machine, 3.5 Line-per-second Printing 12 Digits 12 Digits Whiote: White Product Type: Adding Machine, Desktop Type Key Function: Key Rollover Shift Key, Sign Change, Mark Up And Down Power Supply: Ac Adapter Only Auto Power Off Weight: 1400 G Memory: 376.5 X 204.5 X 111.2 Mm Menro (p 25,000.00) Comb Bookbinding Machine (document Format;format; A5, 1 Unit A4 And Legal Size / Punch Capacity; 20 Sheets / Bind Capacity; 300 Sheets / Method Of Operating; Manual Punching & Manual Binding / Number Of Punch Holes; 35 / Comb Storage; Yes / Maximum Comb Size; 38mm / Weight: 9.5kg / Vertical Load / Adjustable Edge / Document Measurement Too / And 1-year Warranty) Mcr (p 51,000.00) Nas 1 Unit 1 Year Warranty * 2 X 3.5" Sata Hdd/ssd Drive Bays * Realtek Rtd4 * Compatible Drive Type 2 X 3.5" 2.5" Sata Hdd3 (drive Not Included) * External Port 2 X Usd 3.0 Port * Size (hxwxd) 165 X100 X 225.5 Mm * Maximum Internal Raw Capacity 32 Tb (16tb Drive X 2) (capacity May Vary By Raid Types) Usb Hub 1 Unit Usb 3.0 N& Usb-c 2-in-1 Interface To 4-port Usb 3.0 Hub; Length; 1m Ups 1 Unit 1 Year Warranty * Ratings: 2000/va / 1200w* Battery; 2 X12v/9ah * Interface: 6x Universal Socket Led Indicators* Size: 125 X 380 X 225mm* Weigth: 14.8kg * Led Display Or Lcd Ddisplay Selectable * Microprocessor Based Digital Control * Boost And Buck Avr For Voltage Stabilization * Auto Sensing Frequency * Wide Input Voltage Range * Powert On Self Test * Cold Start * Auto Restart When Mains Power Is Restored Auto Track Mains Phase To Ensure That Inverter Output Voltage Has Same Phase With Utility Voltage, Reducing Transfer Time And Peak Surge * Intelligent Battery Management: Battery Management: Battery Temperature Compensation To Extend--the Battery Life; Three- Stage Charging To Shorten Recharge Time * Short Circuit, Battery Overcharge/ Overdischarge, Overload, Surge Protections Printer 1 Unit 1 Year Waranty * Print, Scan, Copy, Fax With Adf * Print Direction; * Bi-direction Printing * Technology; * Precision Core Printhead * Nozzle Configuration: * 400 X 1 Nozzles Black, 128 X 1 Nozzles Per Colour (cyan, Magenta, Yellow) * Minimum Droplet Size; * 3.3 Pl * Maximum Resolution; 4800 X 1200 Dpi (with Variable-sized Droplet Technology * Automatic 2-sided Printing; * No * Photo Default - 10 X 15 Cm / 4 X 6" *2: * Approx. 69 Per Photo (border) / 90 Sec Per Photo (borderless) * Draft, A4 Black / Colour); * Up To 33.0 Ppm / 20.0 Ppm * Iso 24734, A4 Simplex (black / Colour); * Simplex: Up To 15.0 Ipm * First Page Out Time From Ready Mode (black / Colour): * Approx: 10 Sec / 16 Sec * Scan Speed (flatbed / Adf (simplex): * 200dpi, Black: 12 Sec / Up To 4.5 Ipm Vacuum Cleaner 1 Unit 800w Power Motor, Strong Suction Blowing Function, Clipper Built Appearance Complete; 1 Year Warranty; Complete Accessories; 220v / 60hz,thermal Protection: 150c, Dust Capacity; 0.5, Airflow; 840l Vice Mayor's Office (p 83,500.00) Digital Voice Recorder 1 Unit General Features: Built-in Lithium Battery; 4gb Built-in Memory; With Built-in Microphone: Stereo (s-mic); With Calendar Search; With Lcd Backlight; With 199 Maximum Files Per Folder And 5,000 Maximum Files (total) (including Number Of Folder); Connectivity; With Playback Formal(lpcm/mp3/aac/wma); With Linear Pcm/mp3 Recording Format And Usb Connection Charging Recording: With Scene Select; With Low-cut Filter; With Fm Radio Recording; With Sync Recording Function; With Vor; With Recording Monitor; Playback & Edit: With A-b Repeat; With Folder Name Change; With Digital Pitch Control; With Graphic Equalizer; Withdivide, Move File, Easy Search, Noise Cut, Erase, Protect, File Copy, Tack Mark 1 Year Warranty All-in One Inkjet Color Printer With Integrated Ink Tank System 1 Unit Print: Pribnting Technology: On-demand Inkjet (piezoelectric) Nozzle Configuration: 180x1 Nozzles Lack, 59x1 Nozzles Per Colour (cyan, Magenta, Yellow) Print Direction: Bi-directional Printing. Maximum Print Resolution: 5670x1440 Dpi (with Variable Sized Droplet Technology) Print Speed: Draft, A4 (black/colour): Up To 10ipm/5.0ipm Copy: Copy Quality: Colour/black-and-white; Draft/standard Maximum Copies From Standalone: 20 Copies, Maximnum Copy Siz: A4, Letter Max Copy Resolution: 300x300 Dpi Scan: Scanner Type: Flatbed Colour Image Scanner Optical Resolution: 600x1200 Dpi, Maximum Scan Area: 216x297 Mm (8.5 X 11.7) Flatbed (black/colour): 200 Dpi: 11 Sec/200 Dpi: 32 Sec, Dimensions (wxdxh): 375x347x179 Mm, Weight: 3.9 Kg. 1 Year Warrante Wet And Dry Heavy Duty Vacuum Cleaner 1 Unit Drum Size (gallons): 12-cord Length: 15 Ft. Accessory Size: 2 1/2" - Net Weight: 16.5 Lb - Built-in Accessory Storage: Yes - Built-in Drain: Yes Casters: Yes - Include: Vac, Wet Nozzle, Utility Nozzle, Car Nozzle, Hose, 2 Extrension Wands, Filter - Reconditioned: No - Refunable: 90 Days - Filter Type: Cartridge - Incvluded Filter: Vf4000 - U.l. Listed: Yes Motor: Peak Hp 5 - Air Volume (cfm): 141 - Amperage (amps): 10- Voltage: 120 85 Liters Smart Oven 1 Unit Product Type: Convection - Installation Type: Freestanding Oven Capacity: 35l (1.2 Cu.ft) - Color (door): Clean Charcoal - Color (cabinet): Black Control Method Full Touch - Door Type: Drop Down - Cavity Material: Ceramic Enamel - Turntable Size: 380mm - Display Type Led (white) - Convection And Grill Heater: Sheath Power/ratings Power Source: 230v/60hz - Output Power (microwave): 900 W- Power Consumption - (microwave): 1400 W - Power Consumption (grill): 2250 W - Power Consumption - (convection): 2500 W - Power Consumption (max): 2850 W - Power Level: 7 Features: Various Cooking Mode - Convection Temperature: 40-230 *c - Preheat: Keep Warm Clock: 30 Sec. Plus - Eco Mode: Defrost (auto/power/sensor) - Steam Cook - Auto Programs - Auto Cook - Air Fry - Dough Proof/yogurt - Turntable On/off - Child Safety Lock - Sound On/off Accessories: Wire Rack - Crusty Plate - Pro Steamer - Quick Guide Label Weights/dimensions: Cavity (wxhxd): 400x219x396.5 Mm Outside (wxhxd): 528x404x481 Mm Shipping (wxhxd): 596x467x553 Mm Weight (net): 27.5 Kg Weight (shipping): 33.5 Kg Loading Quantity (20/40 Ft): 185/410 1 Year Warranty Coffee Maker 1 Pc Coffee Machine Capacity: 5 To 8 Cups Weight: 0.83 Kg Color: Black Coffee Machinetype: Filter Input Voltage: 220v Power Consumptuion: 600w Features & Benefits: 0.6 Liters Or 5 Cups Capacity Anti-drip Function Long Life Permanent Filter Heat Resistant Glass Carafe Technical Specifications: Power Rating: 600 Watts Voltage Rating: 220v 60 Hz Unit Weight: 0.83 Kg 1 Year Warranty Sangguniang Bayan (p 67,000.00) Bar Code Scanner 10 Pc Rugged And Stylish Design Quick And Fluent Reading Performance Laser Scanner With Auto Scan And Bracket Bracket Dissaasembled To Saving Shipping Cost With Ip52 Waterproof And Dustproof Protection Usb Standard Interface Stand Sold Together 1 Year Warranty Coffee Maker 10 Pc Coffee Machine Capacity: 5 To 8 Cups Weight: 0.83 Kg Color: Black Coffee Machinetype: Filter Input Voltage: 220v Power Consumptuion: 600w Features & Benefits: 0.6 Liters Or 5 Cups Capacity Anti-drip Function Long Life Permanent Filter Heat Resistant Glass Carafe Technical Specifications: Power Rating: 600 Watts Voltage Rating: 220v 60 Hz Unit Weight: 0.83 Kg 1 Year Warranty ***nothing Follows*** Bid Amount Shall Not Exceed The Approved Budget For Each Department / Office Total
Closing Date26 Apr 2024
Tender AmountPHP 829 K (USD 14.4 K)
Adela Serra Ty Memorial Medical Center Tender
Healthcare and Medicine
Philippines
Details: Description Invitation To Bid For Procurement Of Medical Equipment Color Doppler Ultrasound System Ib No. 2024-04-30 (16) 1. The [adela Serra Ty Memorial Medical Center], Through Astmmc Fund, Intends To Apply The Sum Of [seven Million\ Pesos Only (php 7,000,000.00)] Being The Abc To Payments Under The Contract For [procurement Of Medical Equipment Color Doppler Ultrasound System / Ib No. 2024-04-30 (16)]. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. 2. The [adela Serra Ty Memorial Medical Center] Now Invites Bids For The Above Procurement Project. Delivery Of The Goods Is Required By 60 To 90 Calendar Days. Bidders Should Have Completed, Within [5 Years] From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. A. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From [adela Serra Ty Memorial Medical Center] And Inspect The Bidding Documents At The Address Given Below During [8:00am To 12:00; 1:00 To 5:00pm, Monday Thru Friday]. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On [april 10, 2024 To April 30, 2024] From The Given Address And Astmmc Website And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of [ Ten Thousand Pesos Only (php 10,000.00]. The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees In The Manner Whether It Will Be Presented In Person, By Facsimile, Or Through Electronic Means.]} 6. The [adela Serra Ty Memorial Medical Center] Will Hold A Pre-bid Conference On [10:00am; April 18, 2024] At [bac Conference Room, 2nd Floor, Opd Building, Astmmc, Tandag City]and/or Through Video Conferencing Or Webcasting Via Google Meet, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address Indicated Below On Or Before [10:00am; April 30, 2024]. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On [10:01am; April 30, 2024] At The Given Address Below And/or Via Google Meet. 9bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. The [adela Serra Ty Memorial Medical Center] Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. For Further Information, Please Refer To: Randell A. Sanchez, Ce Bac Office] Astmmc, Capitol Hills, Tandag City Tel No. 086-2114306] Email Address: Astmmcprocurement@gmail.com 12. You May Visit The Following Websites: For Downloading Of Bidding Documents: [astmmc Website] 1 Color Doppler Ultrasound System With 3d/4d For Cardiovascular And Viewer Workstation (high End) 1 7,000,000.00 Overview Of Functional Requirements This Tender Calls For A High End Digital Color Doppler Ultrasound System Designed For Various Clinical Applications. General-purpose Ultrasound Imaging System An Assembly Of Devices Designed To Be Used In A Wide Variety Of Both Extracorporeal And/or Intracorporeal (endography Or Endoscopic) Ultrasound Imaging Procedures. A General-purpose System Supports A Wide Variety Of Transducers And Related Application Software Packages Allowing For The Collection, Display And Analysis Of Ultrasound Information. Usages Are, E.g., General-purpose Imaging, Cardiac, Ob/gyn, Endoscopy, Breast, Prostate, Vascular, Intra-surgical, Abdominal, Vascular, Obstetrics, Gynecology, Neonatal, Pediatric, Urology, Transcranial, Cardiac And Small Parts Applications. Colour Doppler, Depending On The Operating System Specific Software Packages And Compatible Ultrasound Transducers. Standard Features 4d Real Time Real Time Moving Three Dimensional Imaging Capability 3d Static Three Dimensional Imaging Capability Renderlive Simplifies Volume Rendering By Automating Render-line Placement In 3d And 4d Imaging Hdlive Silhouette Dynamically Apply Targeted Transparency To Rendered Structures For A More Thorough View Of Anatomy From A Solid Surface Structure To Developing Internal Anatomy Advanced Volume Contrast Imaging Adjusts Slice Thickness On 3d Or 4d Images To Helps Enhance Contrast Resolution With Use Of Render Techniques. Can Be Applied In The Acquisition Plane, Static 3d Volume Imaging View Obtain Any Plane From A 3d Or 4d Volume By Simply Drawing A Line, Curve, Poly-line Or Trace Through A Structure. This Valuable Technology Enables Views Of Even Irregularly Shaped Structures Not Attainable In 2d Imaging Tomographic Ultrasound Imaging (tui) Simplify Analysis And Documentation Of Dynamic Studies With A Simultaneous View Of Multiple Parallel Slices Of A Volume Data Set Hd-flow B-directional Doppler Feature Reduces Overrating And Increases Sensitivity Over Conventional Color Doppler Radiant Flow Enhanced Visualization Of Vessel Separation With A Dynamic Perception Of Blood Flow During 2d Imaging - Uses Advanced Algorithms To Interpret Sensitive Color Doppler Signals, Which Adds Height & Depth Information To Provide A 3d-like Appearance Fetal Biometry Semi-automated Measurements Of Fetal Biometry Such As Bpd, Hc, Ac, Fl And Hl Automated Volume Calculation Technique (avc) Follicle Automatically Calculates The Number, Dimensions, And Volume Of Hypoechoic Structures In A Volume Sweep To Help Monitor Patient Follicles Faster Count Antral Follicles Automatically Counts The Number Of Antral Follicles In The Ovary And Helps Categorize Into User Defined Size Groups Spontaneous Coronary Artery Dissection (scad) Heart Helps Standardize Image Orientation Of The Fetal Heart By Providing Six Relevant Views For The Fetal Heart As Outlined By Aium, Acog, Acr And Isuog (lvot, Rvot, Stomach, 3vt, Ductal Arch, Aortic Arch) Nt And It Semi-automated Measurement Of Nuchal Translucency And Intra Translucency Thickness. Spatio-temporal Image Correlation (stic) Acquisition Of Volume Data From The Fetal Heart And Connections, Allowing Multiplane And Surface Reconstruction Of The Heart Anatomy Anatomical M-mode (amm) Two Simultaneous M Mode Tracing Through Separate Areas Of The Fetal Heart. Facilitates Arrhythmia Assessment And Cardiac Measurements Wide Sector (max Angle) Utilizes Proprietary Beam Steering Technology On Curved Array Probes To Enlarge The Field Of View Elastography With Quantification A Non-invasive Method In Which Images Demonstrating Elasticity Characteristics Of Tissue Are Used To Help Detect Or Classify Tumors. B-flow A Technique That Uses Digitally Encoded Technology To Provide Direct Visualization Of Blood Echoes In Gray Scale. Coded Harmonic Imaging (hi) Enhances Near Field Resolution For Improved Small Parts Imaging As Well As Far Field Penetration. It Diminishes Low Frequency Amplitude, Noise Improve Imaging Technically Difficult Patient. Coded Excitation (ce) Improves Image Resolution And Penetration In The Far Field. Helps Enable The Use Of A Higher Frequency In Technically Difficult Patients Advance Speckle Reduction Imaging (sri) Adaptive Algorithm To Decrease Speckle That Is An Inherent Artifact In All Ultrasound Images. Combine Multiple Image Helps Enhance Tissue And Border Differentiation With An Innovative, Real-time Spatial Compounding Acquisition And Processing Technique Hd Zoom High-resolution Zoom For Localize Regions Of Interest For Closer Study View Ability To Steer The Direction Of The Image In Endocavity Probe Using The Mechanical Motor Touch Screen Unique Touch Panel Interface With Smart, Intuitive 3d Manipulations Capabilties Like X/y/z Rotations –pinch /zoom And Magicut Functionality Probes Convex Array Probe Wideband Convex 2d Abdominal Probe (2 – 5 Mhz) 'applications: Abdomen, Ob, Gyn Wideband Microconvex Intercavity Array Ultrasound Probe Wideband Micro-convex 2d Endocavity Probe (2.9 – 9.7 Mhz) 'applications: Ob, Gyn, Transrectal Ultralight, Wideband Real Time 4d Convex Array Ultrasound Probe Wideband Convex Ultra-light (abdominal) 4d Volume Probe (2 – 8 Mhz) 'applications: Abdomen, Obstetrics, Gynecology, Pediatrics Realtime 4d Endocavity Probe-a Wideband Micro-convex (endocavity) 4d Volume Probe (3.8 – 9.3 Mhz) 'applications: Obstetrics, Gynecology, Transrectal Dicom 3.0 Connectivity Brightness Mode (b-mode) (2d) Motion Mode – M-mode (conventional M-mode) Pulsed Wave Doppler (pw) Color Flow Doppler Mode (cfm) Power Doppler Mode (pd) 3d/4d Volume Mode High Resolution Alteast 23” Led Monitor With Full Hd Resolution Of At Least 1920 X 1080 Atleast 10.1” High Resolution Color Touch Panel 4 Active Probe Ports 6 Programmable Print/store/export Keys For Printing, Archiving And Exporting Backlit Alphanumeric Keyboard And Customizable Trackball Back Light Color System Processing Channel Technology Integrated Dvd+r(w)/cd-r(w) Drive Battery Pack Probe Favorites Technical Specifications Console Design • 4 Active Probe Ports • Integrated Hdd (at Least 1tb) • Integrated Dvd-r Multi Drive • On-board Storage Of Thermal Printer • Integrated Speakers With Sub[1]woofer For Premium Sound • Integrated Locking Mechanism That Provides Rolling Lock And Caster 'swivel Lock • Integrated Cable Management • Front And Rear Handles • Easily Removable Air Filters Operator Keyboard • Floating Keyboard Adjustable In Three Dimensions: • Height • Rotation • Extension • Full-sized, Backlit Alphanumeric Keyboard • Ergonomic Hard Key Layout • Interactive Back-lighting • Integrated Recording Keys For Remote Control Of Up To 4 Peripheral Or Dicom Devices • Integrated Gel Warmer Touch Screen • Atleast 10.4 In High Resolution, Color, Touch, Lcd Screen • Interactive Dynamic Software Menu • Brightness Adjustment • User-configurable Layout Lcd Monitor • Atleast 19′′ High-resolution Lcd • Lcd Translation (independent Of Console): • Atleast 350 Mm, 13.7 In Horizontal • Atleast 90° Swivel • Fold-down And Lock Mechanism For Transportation • Brightness & Contrast Adjustment • Resolution: 1280 X 1024 • Horizontal/vertical Viewing Angle Of +/- 170° System Application System Overview Scanning Methods Applications • Electronic Sector • Abdominal • Electronic Convex • Obstetrical • Electronic Linear • Gynecological • Mechanical Volume Sweep • Breast Transducer Types • Small Parts • Sector Phased Array • Vascular /peripheral • Convex Array • Transcranial • Micro Convex Array • Pediatric And Neonatal • Linear Array • Musculoskeletal • Matrix Array • Urological • Volume Probes (4d) • Cardiac • Convex Array Operating Modes • Micro Convex Array • B-mode • Linear Array • M-mode • Split Crystal • Color Flow Mode (cfm) System Standard • Extended Field Of View (option) Features • Power Doppler Imaging (pdi) • Advanced User Interface With High 'resolution 10.4 Inch Lcd Touch Panel • Pw Doppler • Automatic Optimization • Cw Doppler • Volume Modes (3d/4d): • Speckle Reduction Imaging (sri-hd) • 3d Static • Fine Angle Steer • 4d Real Time (option) • Coded Harmonic Imaging • Anatomical M-mode • Virtual Convex • Coded Contrast Imaging (option) • Patient Information Database • Elastography (option) • Image Archive On Integrated Peripheral Options Cd/dvd And Hard Drive • Integrated Options For: • Advanced 3d • Digital B&w Thermal Printer • Raw Data Analysis • Dvd Video Recorder • Real-time Automatic Doppler Calcs • Digital Color Thermal Printer • Ob Calcs • Digital A6 Color Thermal Printer • Fetal Trending • External Usb Printer Connection • Multigestational Calcs • Dvi-i Output Available For Compatible Devices • Hip Dysplasia Calcs • Foot Switch, With Programmable Functionality • Gynecological Calcs • Console Protective Cover Display Modes • Vascular Calcs • Live And Stored Display Format: Full Size And Split Screen - Both W/ Thumbnails • Urological Calcs • Review Image Format: 4x4, And "thumbnails". • Renal Calcs • Simultaneous Capability • Cardiac Calcs • B Or /pw • Insite Exc Capability • B Or /cfm Or Pdi • On-board Electronic Documentation • B/m Connectivity & Dicom • B/ • Ethernet Network Connection • Real-time Triplex Mode (b Or + Cfm Or Pdi/pw) • Wireless Lan • Selectable Alternating Modes • Dicom 3.0 • B Or /pw • Verify • B Or + Cfm (pdi)/pw • Print • B/cw (option) • Store • Multi-image (split/quad Screen) • Modality Worklist • Live And/or Frozen • Storage Commitment • B Or + B Or /cfm Or Pdi • Modality Performed Procedure • Pw/m Step (mpps) • Independent Cine Playback • Media Exchange • Time Line Display • Off Network / Mobile Storage • Independent Dual B Or /pw Display Queue • Cw • Query / Retrieve • Display Formats Top/ Bottom Selectable Format Side/side Selectable Format • Public Sr Template • Virtual Convex • Structured Reporting – Compatible With Vascular And Ob Standard • Insite Exc Capability Includes: - Viewing Workstation - 1 Unit 55" Smart Tv For Viewing Of Patient Computer Specifications * 1 Unit Branded Computer System Alteast 16cores Up Processor 3.5ghz Up With 32gb Of Ram And Dedicated Video Card Atleast 8gb Gddr5 24 Inches Monitor With Wireless Adapter, Ups, Mouse, Keyboard, Speaker And Other Accessories Needed * Provide Wireless & Wired Access Point For Pacsplus & Dicom (router & Switchub) * 2 Units Branded Laptop Atleast 19" With Viewing System For Ultrasound Syncronizing To Ultrasound '-16 Core, 1 Tb With Bag & Wireless Mouse * 2 Units Rotating Chair Adjustible Up & Down * 1 Unit Modern Table Hard Structure Steel And Chrome Plated Or Stainless * 2kva Ups With Avr Computer Grade For Workstation - 50 Pcs Ultrasound Printer Paper - 3kva Ups Medical Grade With Trolly For Ultrasound Consumables - 20 Pcs Ultrasound Printer Thermal Paper - 10 Gallons Of Ultrasound Gel Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Staff/end-user And Biomed Technician In Coordination With The Engineering Department To Affirm Completion Of Installation Training End Users & Biomedical/engineer Training Of Users And Biomedical *** Training Of Users In Operation And Basic Maintenance And Calibration Shall Be Provided *** Supplier To Issue Certificate Of Training *** Comprehensive Training Of Users In Operation , Basic And Advance Maintenance Shall Be Provided *** Off-site Comprehensive 2 End Users Participants Can Attend For One Week Technical Training & Orientation Of In Including Fares, Accommodation And Meals *** Off-site Comprehensive Training 4-6 Biomed Technician Participants Can Attend For One Week Technical Training & Orientation Of Biomedical Technician/engineer In Including Fares, Accommodation And Meals User Care*** Unit Layout To Enable Easy Cleaning And Sterilization Of All Surfaces. Warranty And Maintenance Warranty 3 Years Warranty Should Be Provided By The Supplier Parts = At Least 3 Years Maintenance And Service = At Least 2 Years Maintenance Tasks *semi-annual Preventive Maintenance/calibration To Be Conducted By The Company Engineer In-charge *advanced Maintenance Tasks Required Shall Be Documented *radiology As The Need Arise Type Of Service Contract Service Contract Is Recommended In Case No In-house Service Experience Is Available To Ensure That Preventive Maintenance Will Be Performed At Regular Intervals. Pricing For Service Contracts Should Be Negotiated Before The System Is Purchased. Spare Parts Availability Post-warranty 10 Years Software / Hardware Upgrade Availability Routine Software Updates Should Be Provided Documentation: Documentation Requirements - User, Technical And Maintenance Manuals To Be Supplied In English Language - At Least 3 Copies - Certificate Of Calibration And Inspection To Be Provided - List Of Equipment And Procedures Required For Local Calibration And Routine Maintenance To Be Provided By The Supplier - List Of Important Spare Parts And Accessories, With Their Part Numbers And Cost To Be Provided By The Supplier Decommissioning Estimated Life Span: 10 Years Safety And Standards Risk Classification Regulatory Approval / Certification Should Be A Ce Or Ul Approved Product. "manufacturer / Supplier Should Have Iso Certificate For Quality Standard. Electrical Safety Conforms To Standards
Closing Date30 Apr 2024
Tender AmountPHP 7 Million (USD 121.1 K)
Las Pi as General Hospital And Satellite Trauma Center Tender
Healthcare and Medicine...+1Machinery and Tools
Philippines
Details: Description Supply, Delivery, Installation, Testing And Commissioning Of One (1) Set Brand-new 1.5 Tesla Magnetic Resonance Imaging (mri) Machine (early Procurement Activity) (re-bid) A. Magnet • Field Strength: 1.5 Tesla • Magnet Shielding: Active Self-shielding • Type Of Shimming: Passive + Active (dynamic) • Bore Diameter: 60 Cm Or Better • Magnet Cooling Should Be Cryogen-based Or Liquid He Based On Manufacturer’s Standard. In Case Of The Latter Option, It Should Have No Cryogen Refill And No Vent/pipe Requirement. Otherwise, It Should Have Zero Helium Boil-off Technology. • Maximum Fov: At Least 50 Cm In X, Y, And Z-axis. • Magnet Homogeneity Shall Be Less Than Or Equivalent To 0.55 Ppm Guaranteed At 40 Cm Diameter Spherical Volume B. Gradient Strength • Actively Shielded Gradient System • Maximum Amplitude For Each Axis: At Least 33 Mt/m • Maximum Slew Rate For Each Axis: At Least 120 – 125 T/m/s • Rf Transmitter And Receiver Must Both Be Digital • Solid-state Type Rf Amplifier C. Radiofrequency System • The Rf System (transmitter And Receiver) Should Be Computer Controlled, And Fully Digital Type • Rf Transmitter Power Should Be Within The Range Of 10 – 20 Kw • Number Of Independent Digital Rf Channels At Least 16-channels With Corresponding 16 Adcs (analog To Digital Converter) • Proper Rf Shielding Must Be Provided D. Radiofrequency (rf) Coils • The Main Rf Body Coil Shall Be Integrated To The Magnet • Coils To Be Included, But Not Limited To, And Apart From Integrated Rf/body Coil. Channels Should Be In Congruent With The Magnet Offered. I. Head & Neck Coil Ii. Spine Array Coil Iii. Torso / Cardiac Coil Iv. Shoulder Coil V. Knee Coil Vi. Wrist Coil Vii. Foot And Ankle Coil Viii. Breast Coil With Biopsy Compatibility Ix. One (1) Large Flex Coil X. One (1) Small / Pediatric Flex Coil E. Acquisition Software/applications With License • The Following Software/ Applications Are, But Not Limited To The Following And Subject To Radiologists’ Need, Especially For Basic And Comprehensive Whole-body Imaging: I. Se, Fse, Gre, Spoiled Ge (2d And 3d), Fsss, Flair, Multi-shot And Single-shot Epi, Fat-and-water Saturation And Excitation, 2d/3d Tof And Phase Contrast, Ce-mra, Pat Or Equivalent. Ii. Must Have Motion Correction Sequences And Algorithms Iii. Flow Compensations Iv. Thick And Thin Mip V. Stitching / Composing Softwares Vi. Mr Spectroscopy (single And Multiple Voxel) Vii. Mrcp Viii. Mri Cardiac Package Ix. Dti X. Functional Mri Xi. Susceptibility Artifacts Reduction Diffusion Weighted Imaging Xii. Bolus Chasing With Automatic Moving Table Should Be Offered And Should Be Available With Fluoro Triggered Mr Angiography Xiii. Perfusion Imaging With Whole Brain Coverage And In Line Calculation Of The Resulting Hemodynamic Data Xiv. Edwi Or Reveal Diffusion Weighted Imaging For Whole Body Dwi Or Equivalent Feature Must Be Available Xv. Advance Metal Artifact Reduction For Soft Tissue Imaging Near Metal Implants Or Its Manufacturer’s Equivalent Xvi. Advanced Mr Angiography Techniques Xvii. Liver Fat Quantification Techniques Or Its Manufacturers’ Equivalent • The Software/applications Should Be Latest And Capable Of Being Constantly Upgraded To Meet Future Development In Mr Imaging For At Least The Next Ten (10) Years, Without Any Additional Cost. F. Patient Table • Should Be Fully Motorized, Computer-controlled Movements In Vertical And Horizontal Directions • Position Accuracy Of +/- 1.0 Mm Or Better • Must Be Able To Support Patient Load At Least 200 Kg. • Table Height At Its Lowest Position Should Be 60 Cm Or Lower • Should Have Patient Alarm System • Should Have Facility For Manual Traction In Case Of Emergency. • Should Deliver The Protocols For Automatic Bolus Chasing In Peripheral Angiography With The Automatic Table Movement, If Applicable. G. Cooler / Chiller System (maximum Of Tw0 (2) Units) • Modular Colling System • Gradient Coil Chiller • Air-cooled Cryogen Compressor, If Applicable H. Main Console, One (1) Unit • Cpu: At Least 6 Core • Ram: At Least 64 Gb • Hard Drive Capacity: At Least 1 Tb • Cd/dvd Writer, At Least Two (2) Usb Ports • Keyboard And Optical Mouse • Reconstruction Performance Of At Least 30,000 Fft/s At 256 X 256 Matrix For Full Fov • Monitor: Color, Fhd, At Least 23 Inches I. Diagnostic Workstation, One (1) Unit • Pu: At Least 6 Core • Ram: At Least 64 Gb • Hard Drive Capacity: At Least 1 Tb • Cd/dvd Writer, At Least Two (2) Usb Ports • Keyboard And Optical Mouse • Double Monitor: Color, Fhd, At Least 19 Inches J. Air Conditioning System • Two (2) Units Appropriate Air Conditioning System For The Magnet Room/scanning Room. • One (1) Unit Appropriate Air Conditioning System For The Equipment Room. K. Warranty Period • Three (3) Years Comprehensive Warranty On Parts And Service For The Mri System Including Helium And Chiller System. L. Trainings • At Least Two (2) Weeks Training Abroad For At Four (4) Radiologists With Certification. • Unlimited On-site Training For Radiologist Technologists With Certification • At Least Two (2) Weeks Training With Certificate For Two (2) Biomed Engineer And One 91) Health Physicist For Basic Troubleshooting, Preventive Maintenance And Calibration M. Certification That The Brand Being Offered Is In The Local And International Markets For The Past Ten (10) Years; N. Certification That The Same Brand And Model Being Offered Has At Least Two (2) Installations In Government Tertiary Hospitals In The Philippines Within The Past Five (5) Years; O. Certificate That The Principal Manufacturer Have Their Office In The Local Market For More Than Ten (10) Years (bir Or Sec Registration Certificate To Be Submitted) P. One (1) Modular Ups Each Of 90 Kva, To Supply The Gantry, Chiller And Workstation; Q. One (1) Pannel Board; R. One (1) Step-down And Step-up Transformer At 100 Kva Supply, Delivery, Installation, Testing And Commissioning Of One (1) Set Brand-new 128-slice Computed Tomography (ct) Machine A. Gantry • Aperture: At Least 70 Cm • Tilt Range (degrees): ± 30 (digital Or Actual Tilting) • Rotation Speed: 0.35 Seconds Or Faster • Slip Ring: Should Be Provided • Spatial Resolution Of 0.28 Mm Or Lower • Effective Temporal Resolution 30 Ms Or Its Manufacturer’s Equivalent • Distance Focus To Detectors Not More Than 95 Cm Or Manufacturer’s Equivalent • Distance Focus To Scan Plane 55 Cm Or Better B. X-ray Tube • Anode Heat Storage (mhu): 7 Mhu Or Higher • Must Be Dual Focal Spot C. Generator • Generator Type: High Frequency With Computer Control • Power (kw): 70 Kw Or Higher • Minimum Tube Voltage: Minimum 80 Kv Or Lower • Maximum Tube Voltage: At Least 140 Kv Or Higher • Ma Selection Available: 10 To 600ma • Ma Increment: At Least 5 Ma Or Lower D. Detector • Number Of Slices 128 Or Higher • Detector: Solid State Ct Detector Or Equivalent Detector Technology • Data Sampling Rate: Up To 2,320 • Slice Thickness (helical Mode): 0.65mm – 10mm • Slice Thickness (axial Mode) 0.625 Mm – 10 Mm • Scan Field Of View: 500 Mm • Detector Configuration / Effective Length Of [mm]: Detector Elements In Z-axis (at Isocentre) [mm]: Capable Of 54 X 0.625mm Or Higher E. Dose Management • Must Adhere To Alara Principle • Dose Reporting: Must Be Available • Dose Modulation Technique: Must Be Available • Ecg Dose Modulation: Must Be Available • Pediatric-specific Dose Control: Must Be Available • Filters: Must Be Available F. Image Reconstruction • Must Have Workflow And Operational Efficiency Enhancements Through Automatic Patient Positioning With The Use Of Camera And Ai Or Its Equivalent • Scan Field Of View: 50cm Or Higher • Minimum Dfov: 5.0 Cm • Slice Thickness: 0.625mm Or Thinner • Reconstruction Matrix: Must Have 512x512 And 1024x1024 • Display Matrix: At Least 1024 X 1024 • Must Have Iterative Reconstruction Or Equivalent Technology G. Patient Table / Couch • Horizontal Range: 1740 Mm Or Higher • Horizontal Scannable Range (helical): 1580 Mm Or Higher • Horizontal Speed: 175 Mm/sec Or Faster • Helical Pitch: At Least 1.5 Or Higher • Vertical Movement Range (out Of Gantry): ≤430 To ≥990 Mm Or Manufacturer’s Equivalent • Couch Load Capacity: ≥ 215 Kg • Cradle Travel Accuracy/ Reproducibility (mm): At Least +/- 0.25 H. Main Console And Computer • Console I. Console Type: All-in-one Console Capable Of Scan, Acquisition And Post Processing Ii. Display Monitor: Dual With At Least 19 Inches At 1280 X 1024 Resolution Iii. Console Cabinet For Dust Protection Iv. Console Table And Chair • Console Computer I. Hz / Word Size: At Least 6core, 2ghz Or Manufacturer's Latest Technology Ii. Compatible Operating System Iii. Ram: At Least 64gb Or Manufacturer's Latest Technology Iv. Graphics Card: Nvidia Quadro P620 Or Manufacturer’s Latest Configuration V. Keyboard And Mouse • Data Management I. Total Internal Disk Storage Of At Least 2tb (2,000gb) Storage For System/application, Image And Raw/scan Disk Data Or Manufacturer's Latest Storage Capability Ii. Additional Storage: Cd/dvd Iii. His / Ris Interface Worklist / Dicom Mpps: Must Be Available And Should Integrate In The Current His-ris-pacs Of The Hospital Iv. Dicom Viewer: Support For External Dicom Usb Media And Preference Management Tool To Exchange Preferences Across Users I. Independent Post Processing Workstation (radiologist) • Hardware Type/processor: At Least 6 Core, Minimum 3.0 Ghz Or Manufacturer's Latest Specification • Ram: 32gb Or Higher • Graphics Card: At Least 1 Gb • Os And Applications: At Least One (1) 256 Gb Ssd • Image Storage: At Least Two (2) 512gb Ssd In Raid Configuration For Image Protection And Redundancy • Archival Storage: Internal Dvd Writer Drive For Read/write Of Dicom Cd/dvd Media, Read/write Of Data Export Cd/dvd Data And Service Use (dvd Install) • Display Monitor: Dual Configuration, Minimum 19" Lcd • Keyboard And Mouse J. Clinical Facilities And Applications • The Following Software/ Applications Are, But Not Limited To The Following And Subject To Radiologists’ Need, Especially For Basic And Comprehensive Whole-body Imaging: I. Vessel Analysis Software Ii. Bone Removal/subtraction Software Iii. Ct Cerebrovascular Auto Segmentation, Ct Subtraction Iv. Ct Pv. Dental Software Vi. Thoracic Analysis Software, Lung Disease Assessment Vii. Lung Nodule Analysis Software Viii. Ct Pulmonary Analysis Ix. Calcium Scoring X. Cardiac Plaque Assessment Xi. Advance Coronary Ct/cardiac Capabilities Xii. Tavi / Tavr Planning Software Xiii. Myocardial Defect Assessment Xiv. Comprehensive Cardiac Function Analysis Xv. Advance Oncology Software / Ct Lesion Analysis Xvi. Hepatic Liver Analysis Software / Ct Liver Analysis Xvii. Ct Colon Analysis / Virtual Colonoscopy Xviii. Virtual Bronchoscopy Xix. Image Fusion Software With Other Modalities Xx. Dental Scan Software Xxi. Stroke Management / Application Software For Hemorrhagic And Ischemic Infarct Or Its Equivalent Xxii. Must Reduce Metal Artifacts And Improve Image Quality While Preserving Body Structural And Anatomic Details. • The Software/applications Should Be Latest And Capable Of Being Constantly Upgraded To Meet Future Development In Ct Imaging For At Least The Next Ten (10) Years, Without Any Additional Cost. K. Others • Set Of Patient Restraints • Patient Positioning Tools • Water Phantom For Calibration And Testing • Lead Glass For The Control Room • Lead Lining For The Examination Room • System Operator Manual • Software Operator Manual • Must Have Local Installation Of The Same Model In At Least 2 Public/government Hospitals In The Philippines Erfusion Analysis, Ct Volume Perfusion • Must Have Principal Local Presence For After Sales And Support L. Air Conditioning System • Two (2) Units Appropriate Air Conditioning System For The Ct Room/scanning Room. • One (1) Unit Appropriate Air Conditioning System For The Equipment Room. M. Warranty Period • Three (3) Years Comprehensive Warranty On Parts And Service For The Ct Machine N. Trainings • At Least Two (2) Weeks Training Abroad With Certification For At Least Four (4) Radiologists • Unlimited On-site Training For Radiologist Technologists, With Certification • At Least Two (2) Weeks Training With Certificate For Two (2) Biomed Engineers And One (1) Health Physicist For Basic Troubleshooting, Preventive Maintenance And Calibration O. Certification That The Brand Being Offered Is In The Local And International Markets For The Part Ten (10) Years; P. Certification That The Same Brand And Model Being Offered Has At Least Two (2) Local Installations In Government Tertiary Hospitals In The Philippines, Within The Past Five (5) Years; Q. Certificate That The Principal Manufacturer Have Their Office In The Local Market For More Than Ten (10) Years (bir Or Sec Registration Certificate To Be Submitted); R. One (1) Modular Ups Each Of 90 Kva To Supply The Gantry, Chiller And Workstation; S. One (1) A1 Pannel Board Supply, Delivery, Installation, Testing And Commissioning Of Brand-new Mri-compatible And Ct-compatible Accessories / Machine (abc: Php10,000,000.00) A. One (1) Unit Mr Compatible Anesthesia Machine With Ventilator A. Must Be Approved To Use With 1.5 Scanners, At Least 1000 Gauss B. Must Have Gauss Meter Monitoring C. Designed Specifically For Use In An Mri Environment D. Electronic Touchscreen Ventilator E. Standard Six Ventilation Modes, And Support For Spontaneous Breathing Patients F. Total System Compatibility G. Compact Footprint, Optimum Maneuverability H. Two Station Selectatec Compatible Backbar I. With 1 Sevoflurane Vaporizer Selectatec Compatible Stability K. Enclosed Construction – No Hidden Storage Areas L. Illuminated Workspace B. One (1) Unit Mr Compatible Patient Monitor A. Performs Patient Monitoring In An Mri Environment Including All Necessary Vital Parameters During Anesthesia B. The System Is Designed For All Patients: Adults, Children And Neonates C. Compatible With Mri Systems From Any Manufacturers That Have A Field Strength At Least 1.5 Tesla D. Wireless Ecg And Spo2 Sensors E. Color Touchscreen C. One (1) Unit Mr Compatible Power Injector D. One (1) Ct Dual/double Barrel Power Injector E. One (1) Unit Mr Compatible Bp Apparatus For Pediatrics And Adults F . One (1) Unit Mr Compatible Stethoscope For Pedia And Adult G. Two (2) Mr Compatible Wheelchairs H. Two (2) Mr Compatible Iv Stand I. One (1) Mr Compatible Stretcher/gurney J. One (1) Set Mr Compatible Cctv System For Patient Observation K. One (1) Mr Compatible Fire Extinguisher L. One (1) Ct Room Fire Extinguisher M. One (1) Mr Compatible Flexible Patient Transfer Board N. Two (2) Hand-held Metal Detector O. Two (2) Units Multifunctional Printer P. One (1) Mr Compatible O2 Outlet And Sunctipon System Q. One (1) Unit Mr Compatible Music / Audio System With Ear Plugs And Headset Covers And With Intercom System R. One (1) Unit Mr Compatible Oxygen Monitor S. One (1) Mr Coil Cabinet T. Two (2) Units Thermohygrometer With Data Logger U. Two (2) Pcs. Lead Aprons V. Two (2) Pcs. Gonadal Shield W. Two (2) Pcs. Thyroid Shield X. Four (4) Pcs. Hand Gloves Y. Two (2) Pcs. Eye Goggles Z. Ten (10) Microsoft Licenses Aa. One (1) Unit Of M3-chip Laptop, Or Latest Ios With At Least 128gb Unified Memory Bb. Ten (10) Stainless Hospital Waiting Area Chairs Cc. Two (2) Units Hot And Cold-water Dispenser Dd. Two (2) Pcs Wooden Bulletin Boards Ee. Two (2) Units Cd/dvd Dicom Reader And Burner Civil Works For Medical Imaging Department Proposed Medical Imaging Department Equipment Rooms Terms Of Reference For The Proposed Medical Imaging Department Equipment Rooms Objective The Las Piñas General Hospital And Satellite Trauma Center Aims To Renovate Its Medical Imaging Department To Enhance Patients’ Outcomes, Improve Diagnostic Services And Provide A Safer And More Efficient Environment For Both Patients And Healthcare Professionals. The Main Purpose Of This Tor Is To Assist The Contractor In Submitting A Bid Offer To Lpgh&stc That Will Satisfy The Hospital’s Requirements At The Most Feasible, Possible Time And Within The Specified Budget. This Document Aims: 1. To Provide A Background Information Regarding The Preparation And Submission Of The Proposed Project To Contractor. 2. To Provide A Background Information Regarding The Proposed Project Which Should Be Handled In The Shortest Possible Time, At An Acceptable Quality And Performance To The Contractor 3. To Outline The Work Of The Contractor That Has To Be Performed Under The Terms Of Its Contract. I. Project Description A) Project Name Procurement Of Infrastructure Project For The Proposed Medical Imaging Department Equipment Rooms End User: Medical Imaging Department Of Lpgh&stc Floor Area : ±300 Square Meters B) Implementing Agency: Las Pinas General Hospital And Satellite Trauma Center Located At Diego Cera Avenue, Bernabe Compound, Pulang Lupa I, Las Pinas City. Ii. Approved Budget And Duration Of Contract The Contract For The Proposed Project Shall Be Within A Period Of One Hundred Fifty (150) Calendar Days Upon Receipt Of Notice To Proceed And With An Approved Project For The Contract Of Eighteen Million Nine Hundred Twenty-five Thousand Five Hundred Fifty-seven Pesos And 80/100 (php 18,925,557.81). Iii. General Conditions 3.1 The Contractor Shall Supply Labor, Materials, Equipment And Other Necessary Items For The Project With The Following Conditions: 3.1.1 A Building Permit (if Necessary) Must Be Secured From The Building Official Of Las Pinas City And Submitted To Las Pinas General Hospital And Satellite Trauma Center Located At Diego Cera Avenue, Bernabe Compound, Pulang Lupa I, Las Pinas City Prior To Construction. 3.1.2 Conduct Ocular Inspection/site Inspection Prior To The Submission Of Bid. 3.1.3 3.1.4 The Plans, Detailed Drawings, Specifications, Detailed Bill Of Quantities, Terms Of Reference, Contract Agreement And Other Bid Documents Shall Be Considered As Complementing Each Other, So That What Is Mentioned Or Shown In One, Although Not Mentioned In The Other, Shall Be Considered As Appearing On Both. In Case Of Conflict Between The Two, The Same Should Be Referred To The Technical Working Group (twg) For Resolution With The Approval Of The Head Of The Procuring Entity (hope) Of Las Pinas General Hospital And Satellite Trauma Center. 3.1.4 The Construction Shall Be Finished With First Class Workmanship To The Satisfaction Of The Lpgh And Stc. 3.1.5 The Construction Works Shall Conform To The Requirements Of The National Building Code, National Structural Code Of The Philippines, Philippine Mechanical Code Of The Philippines, Philippine Electrical Code, Philippine Electronics Code, Code Of Professional Practice And Other Related Pertinent Practices, Codes In The Philippines As Well As The Local Rules, Regulations And Ordinances Of The City Government And Must Be Acceptable To The Las Pinas General Hospital And Satellite Trauma Center. 3.1.6 Itemized Of Bill Quantities 3.1.6.1 The Items, Description And Quantities Given On The First Three Columns Of The Bill Of Quantities Under Section Viii, Guides Only To The Bidder Interpreting The Plans And Technical Specifications. The Las Pinas General Hospital And Satellite Trauma Center, Bac And Twg Is Not Responsible For Any Mistakes, Inaccuracies, Duplications Or Omissions In This List Of The Bill Of Quantities Which Shall Never Be A Basis For Additions Nor Deletions To The Scope Of Work. Only The Entries Of The Bidder On The Last Three Columns Consisting Of His Own Take Off Quantities From The Plans And Technical Specifications And His Unit Cost And Corresponding Sums Shall Be Considered. 3.1.6.2 The Bill Of Quantities Prepared By The Bidder Cannot Be Used As Basis For Claims For Any Extra Work, But May Only Be Used Solely By The Las Pinas General Hospital And Satellite Trauma Center, Bac And Twg As Aid In Judging If Bid Is A Responsive Bid. 3.1.6.3 The Unit And Total Bid Prices Must Include All Direct And Indirect Cost/ Expenses Such As Overhead, Contingencies And Miscellaneous (ocm); Profit, Plus The Corresponding Value Added Tax And Other Obligations Of Any Kind Under Which The Contract Must Be Borne By The Contractor Since They Are Necessary To Install, Construct And Complete The Whole Of The Contract In Accordance With The Bid Documents. 3.1.7 All Permits And Corresponding Fees As May Be Assessed By The Local Government Unit/regulating Agencies Shall Be On The Account Of The Contractor. 3.1.8 The “green And Safe Health Facilities Manual 1st Edition” Shall Also Form Part Of This Tor Which Comprises Efforts Of The Health Sector That Contribute To The Attainment Of The Country’s Goals Towards Sustainable Development. 3.1.9 The Administrative Order No. 2024- “guidelines For The Implementation Of Projects Funded Under The Health Facility Enhancement Program (hfep) Fiscal Year 2024” Shall Be Part Of This Tor That Serves As A Guide For The Proper And Systematic Implementation And Monitoring Of All Projects Funded Under The Hfep Gaa Fy2024. 3.1.10 The Separate “scope And Specifications” Shall Form Part Of This Tor That Will Serve As Basis To Define The Requirements For Project Execution Regarding Installation, Materials, Products, Procedures, And Quality Aspects. The Scope And Specifications Shall Govern The Coverage And Methods Of Construction And The Kind Of Materials To Be Used For The Proposed Project Shown In The Plans And Detailed Drawings. Iv. Scope Of Works 4.1 Work/operation Plan 4.1.1 The Contractor Shall Submit The Project Work Plan (pertcpm, Gantt Chart, S-curve, Detailed Construction Methods, Project Execution Plan, Construction Safety Health Program, Procurement Plan And Manpower And Equipment Schedule) Consisting Of The Specific Work Activities And Dates Within Ten (10) Calendar Days Upon Receipt Of Notice To Proceed. 4.2 Contractual Scope Of Works 4.2.1 The Contractor Shall Provide Professional Services And Other Support Services Necessary For The Implementation Of The Complete Construction Of The Proposed Project. 4.2.2 The Contractor Shall Be Responsible For Providing Complete Professional Services For All Aspects Of The Proposed Project Including, But Not Limited To The Following: 4.2.2.1 Perform Data Collection And Field Investigation To Determine Actual Site Conditions 4.2.2.2 Submit Construction Methodology Prior To The Start Of The Renovation And After Ocular Inspection And Coordination With Lpgh&stc. 4.3 Construction Phase 4.3.1 The Contractor Shall Prepare, Secure, Submit, Process All Necessary Documents (permits, Clearance, Plans, Etc.) And Payment Of All Assessed Fees And Other Incidental Expenses Related Thereto As May Be Required By The Local Government Unit, Utility Firms (electric Cooperative, Local Water Utilities Administration, Pldt, Etc.) And Other Regulating Agencies. 4.3.2 The Contractor Shall Undertake The Proposed Medical Imaging Department Equipment Rooms And Its Required Infrastructures And Appurtenances In Accordance With The Approved Plans And Designs As Follows: 4.3.2.1 Architectural Plans 4.3.2.2 Other Engineering Plans 4.3.2.3 Project Specifications 4.3.3 The Contractor Shall Designate One (1) Project Manager, One (1) Professional Mechanical Engineer And One (1) Professional Electrical Engineer Who Shall Work During The Construction Period/duration Of The Contract And Shall Only Report On Site When Needed During Project Implementation Or Weekly Infrastructure Meeting. 4.3.4 The Contractor Shall Designate One (1) Project Engineer (civil Engineer), One (1) Project Architect, One (1) Electrical Engineer, One (1) Mechanical Engineer (mepfs), One (1) Safety Officer 2 (so2), One (1) Qa/qc Engineer And One (1) Document Controller/admin Who Shall Work Full Time During The Construction Period/duration Of The Contract And Shall Be In Charge Of The Construction Work And Perform The Following But Not Limited To: 4.3.4.1 Coordinate With The Las Pinas General Hospital And Satellite Trauma Center And Engineering And Facilities Management (efm) Regarding The Implementation Of The Construction Project. 4.3.4.2 Schedule, Oversee And Monitoring The Day-to-day Construction Works. 4.3.4.3 Coordinate, Address And Resolve All Concern/s Of Nearby Buildings And Structures Relative To The Construction And Related Services As Required By Lgu And Other Regulating Agencies. 4.3.4.4 Prepare Daily Activity Reports, Weekly And Monthly Accomplishment Reports Supported With Progress Photographs (geotagged) And S-curves To Monitor Actual Progress Status Report And To Be Used As Basis For Progress Billing. 4.3.4.5 Conduct A Weekly Construction Coordination Meeting With The Las Pinas General Hospital And Satellite Trauma Center, Twg And Infrastructure Committee During Which A Weekly Progress Report On All Activities For The Previous Week Will Be Submitted. 4.3.5 The Contractor Shall Be Responsible In Conducting The Necessary Tests Required. For The Structural Elements, Standard Testing For Concrete And Reinforcing Bars Are Required. The Testing Laboratory Must Be Accredited By Dpwh And Must Be Witnessed By Any Authorized Representatives Of The Lpgh&stc And The Consultant. 4.3.6 The Contractor Shall Be Responsible For Restoring Walls And Structures Of Adjacent Properties At The Vicinity Of The Project Site As May Be Affected During The Construction Works, If Any. 4.3.7 The Contractor Shall Provide All The Necessary Safety Equipment Such As Board- Up And Closure Signages, Mechanical Blowers To Collect Dust During Surface Preparation And Other Required Equipment To Make Sure That The Operations Of The Hospital Will Not Be Affected. 4.3.8 The Contractor Shall Be Responsible In The Hauling And Disposal Of Debris And Other Construction Wastes. 4.3.9 The Contractor Shall Provide All Other Works And/or Materials Not Included In This Terms Of Reference/scope And Specifications/bill Of Quantities But Are Essential For The Satisfactory Completion Of The Project At No Additional Cost To The Las Piñas General Hospital And Satellite Trauma Center. 4.3.10 Other Works Due To The Contractor Are: 4.3.10.1 Supply And Installation Of Accessories 4.3.10.2 Waterproofing Works At Cssd/autoclave Room 4.3.10.3 Restoration, Repair And Rectification Of Cistern Area And Vacuum Room 4.4 Electric And Water Consumption For The Duration Of The Contract Shall Be For The Account Of The Contractor. Contractor To Provide Water And Electric Meter. V. Post Construction Documentation 5.1 The Contractor Shall Submit The Following Project Documentations Within Thirty (30) Calendar Days From The Completion Of The Project. 5.1.1 As-built Plans Duly Signed And Dry-sealed By The Concerned Design Architect And Engineers With His/her Valid Registration/professional License Number, Date Of Registration And Current Ptr Number Affixed/stamped On Every Page/sheet Of The Document Of The Following: • Architectural Plans • Mechanical And Fire Protection Plans • Plumbing And Sanitary Plans • Auxiliary Plans • Other Relative Plan 5.1.2 All Plans And Documents Shall Be Delivered In Sets As Follows: 5.1.2.1 One (1) Set Original Copies, Scaled 1:100 Meter Prepared In Cadd Format, Printed/plotted In Tracing Paper. 5.1.2.2 Five (5) Sets Blue Prints Copies For Each Plan 5.1.2.3 One (1) Set Soft Copy (cadd And Pdf) In Flash Drive. 5.1.2.4 Certificate Of Occupancy (if Necessary) 5.1.2.5 Certificate Of Warranty For One (1) Year To Cover The “one – Year Defects Liability Period” Of The Contractor. Form Of Warranty Shall Be In Accordance With The Provisions Of The “revised Irr Of Republic Act. No. 9184, Otherwise Known As The Government Procurement Act”. 5.1.2.6 Warranty Certificate For All The Equipment Supplied Based On The Warranty Duration Stated In The Specifications Document. 5.1.2.7 Other Documents Processed And Issued In Favor Of The Las Pinas General Hospital And Satellite Trauma Center During The Construction Periods (i.e., Inspection Reports, Building Permits, Official Receipts, And Related Documents Other Than Stated In Section 4.3.1). Vi. Post Construction Warranties 6.1 The Contractor Shall Also Provide Within The One (1) Year Warranty Period At No Additional Cost To The Las Pinas General Hospital And Satellite Trauma Center All Replacement Units/parts With The Same Quality, Standard And Specification For All Other Deliverables. 6.2 The Contractor Shall Provide Warranties On Equipment And Other Deliverables As What Stated In The Scope And Specification. Vii. Safety Enclosures 7.1 Provide Safety Nets (enclosures, Shielding, Coverings, Warning Device, Keep-off Limits Signs, Etc.) Upon The Start Of The Project To Ensure Protection Of The General Public And Preservation Of Damage To Properties. Viii. Provision Of Storage & Material Handling 8.1 The Contractor Shall Store Their Materials, Equipment And Tools Only, In One Place Of The Hospital Premises. The Area Shall Be Coordinated With The Chief Administrative Officer Of Las Pinas General Hospital And Satellite Trauma Center And Efm. It Shall Be Kept Neat And Clean All The Times. Any Damage Thereto Or To The Surrounding Area Arising From Any Accident, Etc. Shall Be Repaired And/or Restored To Its Original Condition. Likewise, Extra Care Shall Be Taken In Storage Of Hazardous Chemicals In Order To Avoid Accident, Explosion And/or Fires. The Job Site Shall Be Cleaned At The End Of Every Working Day. 8.2 Provisions For Securing And Safekeeping The Stored Materials, Tools And Equipment During The Construction Project Shall Be For The Account Of The Contractor. Ix. Clearing Of Site The Contractor Shall Clean The Whole Area By Removing Debris, Discards, Excesses And Spillage And Shall Leave The Entire Premises Free From Rubbish Caused By Their Work To The Satisfaction Of The Las Pinas General Hospital And Satellite Trauma Center At No Extra Cost. X. Service Level Agreement Las Pinas General Hospital And Satellite Trauma Center Shall Maintain A Service Level Agreement (sla) With The Contractor, With Provisions For Liquidated Damages For Their Non-compliance. Xi. Warranties Of The Contractor 11.1 The Contractor Warrants That It Shall Conform Strictly To The Terms And Conditions Of This Terms Of Reference. 11.2 The Contractor Warrants, Represents And Undertakes Reliability Of The Service And That Their Manpower Complements Are Hardworking, Qualified, Reliable And Dedicated To Do The Service Required To The Satisfaction Of The Las Pinas General Hospital And Satellite Trauma Center. It Shall Employ Well-behaved And Honest Employees. They Shall Wear Id And Proper Company Uniform When Working Within The Construction Site. It Shall Not Employ Las Pinas General Hospital And Satellite Trauma Center Employees And Their Relatives Within The Fourth Civil Degree Of Consanguinity Or Affinity To Work In Any Category Whatsoever. 11.3 The Contractor Shall Comply With The Laws Governing Employee’s Compensation, Philhealth, Social Security And/or Labor Standard And Other Laws, Rules And Regulations Applicable To Its Personnel Employed By The Contractor On Account Of Contracted Services. The Contractor Shall Pay Its Personnel Not Less Than Minimum Wage And Other Benefits Mandated By Law. 11.4 The Contractor In Performance Of Its Services Shall Secure, Maintain At Its Own Expense All Registration, Licenses Or Permits Required By National Or Local Laws And Shall Comply With The Rules, Regulations And Directives Of Regulatory Authorities And Commissions. The Contractor Undertakes To Pay All Fees Or Charge Payable To Any Instrumentality Of Government Or To Any Other Duly Constituted Authority Relating To The Construction Project At No Cost To Las Pinas General Hospital And Satellite Trauma Center. 11.5 The Contractor’s Personnel Shall Take All Necessary Precautions For The Safety Of All Persons And Properties At Or Near Their Area Of Work And Shall Comply With All The Standard And Established Safety Regulations, Rules And Practices. A Construction Safety And Health Program Approved By The Dole Must Be Submitted By The Contractor Including The Deployment Of A Full-time Safety Officer On Site. 11.6 The Contractor Shall Coordinate With Any Authorized And/or Designated Las Pinas General Hospital And Satellite Trauma Center Personnel And E&fm In The Performance Of Their Jobs. 11.7 The Contractor Shall Be Liable For Loss, Damages, Or Injury As May Be Due Directly Through The Fault Or Negligence Of Its Personnel. It Shall Assume Responsibility Thereof And The Las Pinas General Hospital And Satellite Trauma Center Shall Be Specifically Released From Any Responsibility Arising Therefrom. 11.8 The Contractor Shall Neither Assign, Transfer, Pledge, Nor Subcontract Any Part Or Interest Therein. 11.9 The Contractor Shall Be Solely Liable To Its Suppliers And The Las Pinas General Hospital And Satellite Trauma Center Shall Be Free From Any Liabilities That May Arise From Contractor-supplier Agreement. Xiii. Contractor’s Qualification 13.1 The Minimum Requirements For The Contractor Are As Follows: 13.1.1 Must Be At Least Five (5) Years In The Construction Business. 13.1.2 Must Have Completed At Least Three (3) Solely Infrastructure Projects In A Hospital. 13.1.3 Must Have At Least Two (2) Certificate Of Very Satisfactory Rating From Client Hospital Signed By The Medical Center Chief Or Its Equivalent For The Above-mentioned Infrastructure Projects. 13.1.4 Must Have An Appropriate Pcab License Of At Least Small B Category
Closing Date6 May 2024
Tender AmountPHP 178.9 Million (USD 3.1 Million)
AZIENDA DI RILIEVO NAZIONALE E DI ALTA SPECIALIZZAZIONE CIVIVO G DI CRISTINA Tender
Italy
Details: Portable Angiography Device. The characteristics considered irreversible by the user are the following: 1) The apparatus must be equipped with robotic and synchronized movements in all directions, with memorization of the acquired positions, controllable via the remote control panel of the bow movements that can be positioned on the Operating Table, With Joystick That Allows An Easy And Intuitive Use For The Operator. Furthermore, this must allow to work autonomously in the sterile field and with absolute certainty to maintain the identified landmarks, a crucial characteristic in the complex procedures of aortic vascular surgery; 2) Another essential feature is the presence, on a motorized device, of anti-collision sensors which safeguard the operator and the patient from accidental impacts; 3) The monoblock system must have generator and tube assembled together, in order to produce less heating, allowing to considerably increase the scanning times and thus avoid thermal blocks of the machine, with possible even drastic consequences for the patient's health. In addition, the monobloc system allows the generation of perfectly regular and well-defined pulses which allow to drastically reduce motion artifacts and the delivered dose. In contrast to the non-monobloc system which has the generator and X-ray tube separate and connected by external high voltage cables, which have a non-negligible impedance, are responsible for motion artifacts and increased dose, as well as presenting an additional bulk of the System; 4) A real rated power of the generator equal to 25kw and not less, an indispensable requirement for complex endovascular surgery to correctly identify the endoprostheses and any radiopaque material to support the procedures, even in obese patients.
Closing Date10 Jul 2024
Tender AmountEUR 200 K (USD 216.2 K)
Universit Degli Studi Di Napoli Federico II Tender
Italy
Details: The intervention concerns the supply of a high resolution mass spectrometer (hrms) with 4.0 software for the characterization of food micronutrients and metabolites by means of targeted and untargeted analyses. In particular, it is a mass spectrometer with a quadrupole filter coupled to an Ft-ms detector based on the new Orbitrap technology which guarantees resolution values up to 120,000 measured at m/z 200, the ability to work in polarity switching allowing complete alternating scans in Positive Ion Mode And 3/8 Negative Ion In A Time Of 0.7 Second At Fixed Resolution (60,000 Fwhm) And A Mass Accuracy Of Less Than 1ppm, With "Internal Calibrant" Infusion System And The Scanning Speed Is Up To 22 Hz The Technical-Functional Characteristics Appropriate To Satisfying The University's Needs Are Reported In The Technical Regulations Attached To The Preliminary Market Consultation Notice Published On The University Website At The Page: Http://www.unina.it. Economic Operators, Even Those Established In Other Member States, Can Present An Expression Of Interest By 12.00 On 09/04/2023, By Sending The Documentation Attached To The Consultation Notice To The Certified E-mail address Garecontratti-s@pec.unina.it Published On The University Website, Provided It Meets The General Requirements (cf. Letter A) - G) of the notice); Eligibility (see Letter H) of the notice); Of Economic-Financial Capacity (see Letter I) and L) of the notice) And of Technical And Professional Capacity (see Letter M) of the notice).
Closing Date1 Aug 2024
Tender AmountEUR 244.8 K (USD 266.6 K)
6051-6060 of 6153 archived Tenders