Brand-new Radiology Machines (1.5 Tesla Mri, 128-slice Ct Scan Machine And Its Compatible Accessories / Machines) And Civil Works For The Medical Imaging Department (rebid) , Hospital / Medical Equipment ,las Piñas General Hospital And Satellite Trauma Center
Description
Description Supply, Delivery, Installation, Testing And Commissioning Of One (1) Set Brand-new 1.5 Tesla Magnetic Resonance Imaging (mri) Machine (early Procurement Activity) (re-bid) A. Magnet • Field Strength: 1.5 Tesla • Magnet Shielding: Active Self-shielding • Type Of Shimming: Passive + Active (dynamic) • Bore Diameter: 60 Cm Or Better • Magnet Cooling Should Be Cryogen-based Or Liquid He Based On Manufacturer’s Standard. In Case Of The Latter Option, It Should Have No Cryogen Refill And No Vent/pipe Requirement. Otherwise, It Should Have Zero Helium Boil-off Technology. • Maximum Fov: At Least 50 Cm In X, Y, And Z-axis. • Magnet Homogeneity Shall Be Less Than Or Equivalent To 0.55 Ppm Guaranteed At 40 Cm Diameter Spherical Volume B. Gradient Strength • Actively Shielded Gradient System • Maximum Amplitude For Each Axis: At Least 33 Mt/m • Maximum Slew Rate For Each Axis: At Least 120 – 125 T/m/s • Rf Transmitter And Receiver Must Both Be Digital • Solid-state Type Rf Amplifier C. Radiofrequency System • The Rf System (transmitter And Receiver) Should Be Computer Controlled, And Fully Digital Type • Rf Transmitter Power Should Be Within The Range Of 10 – 20 Kw • Number Of Independent Digital Rf Channels At Least 16-channels With Corresponding 16 Adcs (analog To Digital Converter) • Proper Rf Shielding Must Be Provided D. Radiofrequency (rf) Coils • The Main Rf Body Coil Shall Be Integrated To The Magnet • Coils To Be Included, But Not Limited To, And Apart From Integrated Rf/body Coil. Channels Should Be In Congruent With The Magnet Offered. I. Head & Neck Coil Ii. Spine Array Coil Iii. Torso / Cardiac Coil Iv. Shoulder Coil V. Knee Coil Vi. Wrist Coil Vii. Foot And Ankle Coil Viii. Breast Coil With Biopsy Compatibility Ix. One (1) Large Flex Coil X. One (1) Small / Pediatric Flex Coil E. Acquisition Software/applications With License • The Following Software/ Applications Are, But Not Limited To The Following And Subject To Radiologists’ Need, Especially For Basic And Comprehensive Whole-body Imaging: I. Se, Fse, Gre, Spoiled Ge (2d And 3d), Fsss, Flair, Multi-shot And Single-shot Epi, Fat-and-water Saturation And Excitation, 2d/3d Tof And Phase Contrast, Ce-mra, Pat Or Equivalent. Ii. Must Have Motion Correction Sequences And Algorithms Iii. Flow Compensations Iv. Thick And Thin Mip V. Stitching / Composing Softwares Vi. Mr Spectroscopy (single And Multiple Voxel) Vii. Mrcp Viii. Mri Cardiac Package Ix. Dti X. Functional Mri Xi. Susceptibility Artifacts Reduction Diffusion Weighted Imaging Xii. Bolus Chasing With Automatic Moving Table Should Be Offered And Should Be Available With Fluoro Triggered Mr Angiography Xiii. Perfusion Imaging With Whole Brain Coverage And In Line Calculation Of The Resulting Hemodynamic Data Xiv. Edwi Or Reveal Diffusion Weighted Imaging For Whole Body Dwi Or Equivalent Feature Must Be Available Xv. Advance Metal Artifact Reduction For Soft Tissue Imaging Near Metal Implants Or Its Manufacturer’s Equivalent Xvi. Advanced Mr Angiography Techniques Xvii. Liver Fat Quantification Techniques Or Its Manufacturers’ Equivalent • The Software/applications Should Be Latest And Capable Of Being Constantly Upgraded To Meet Future Development In Mr Imaging For At Least The Next Ten (10) Years, Without Any Additional Cost. F. Patient Table • Should Be Fully Motorized, Computer-controlled Movements In Vertical And Horizontal Directions • Position Accuracy Of +/- 1.0 Mm Or Better • Must Be Able To Support Patient Load At Least 200 Kg. • Table Height At Its Lowest Position Should Be 60 Cm Or Lower • Should Have Patient Alarm System • Should Have Facility For Manual Traction In Case Of Emergency. • Should Deliver The Protocols For Automatic Bolus Chasing In Peripheral Angiography With The Automatic Table Movement, If Applicable. G. Cooler / Chiller System (maximum Of Tw0 (2) Units) • Modular Colling System • Gradient Coil Chiller • Air-cooled Cryogen Compressor, If Applicable H. Main Console, One (1) Unit • Cpu: At Least 6 Core • Ram: At Least 64 Gb • Hard Drive Capacity: At Least 1 Tb • Cd/dvd Writer, At Least Two (2) Usb Ports • Keyboard And Optical Mouse • Reconstruction Performance Of At Least 30,000 Fft/s At 256 X 256 Matrix For Full Fov • Monitor: Color, Fhd, At Least 23 Inches I. Diagnostic Workstation, One (1) Unit • Pu: At Least 6 Core • Ram: At Least 64 Gb • Hard Drive Capacity: At Least 1 Tb • Cd/dvd Writer, At Least Two (2) Usb Ports • Keyboard And Optical Mouse • Double Monitor: Color, Fhd, At Least 19 Inches J. Air Conditioning System • Two (2) Units Appropriate Air Conditioning System For The Magnet Room/scanning Room. • One (1) Unit Appropriate Air Conditioning System For The Equipment Room. K. Warranty Period • Three (3) Years Comprehensive Warranty On Parts And Service For The Mri System Including Helium And Chiller System. L. Trainings • At Least Two (2) Weeks Training Abroad For At Four (4) Radiologists With Certification. • Unlimited On-site Training For Radiologist Technologists With Certification • At Least Two (2) Weeks Training With Certificate For Two (2) Biomed Engineer And One 91) Health Physicist For Basic Troubleshooting, Preventive Maintenance And Calibration M. Certification That The Brand Being Offered Is In The Local And International Markets For The Past Ten (10) Years; N. Certification That The Same Brand And Model Being Offered Has At Least Two (2) Installations In Government Tertiary Hospitals In The Philippines Within The Past Five (5) Years; O. Certificate That The Principal Manufacturer Have Their Office In The Local Market For More Than Ten (10) Years (bir Or Sec Registration Certificate To Be Submitted) P. One (1) Modular Ups Each Of 90 Kva, To Supply The Gantry, Chiller And Workstation; Q. One (1) Pannel Board; R. One (1) Step-down And Step-up Transformer At 100 Kva Supply, Delivery, Installation, Testing And Commissioning Of One (1) Set Brand-new 128-slice Computed Tomography (ct) Machine A. Gantry • Aperture: At Least 70 Cm • Tilt Range (degrees): ± 30 (digital Or Actual Tilting) • Rotation Speed: 0.35 Seconds Or Faster • Slip Ring: Should Be Provided • Spatial Resolution Of 0.28 Mm Or Lower • Effective Temporal Resolution 30 Ms Or Its Manufacturer’s Equivalent • Distance Focus To Detectors Not More Than 95 Cm Or Manufacturer’s Equivalent • Distance Focus To Scan Plane 55 Cm Or Better B. X-ray Tube • Anode Heat Storage (mhu): 7 Mhu Or Higher • Must Be Dual Focal Spot C. Generator • Generator Type: High Frequency With Computer Control • Power (kw): 70 Kw Or Higher • Minimum Tube Voltage: Minimum 80 Kv Or Lower • Maximum Tube Voltage: At Least 140 Kv Or Higher • Ma Selection Available: 10 To 600ma • Ma Increment: At Least 5 Ma Or Lower D. Detector • Number Of Slices 128 Or Higher • Detector: Solid State Ct Detector Or Equivalent Detector Technology • Data Sampling Rate: Up To 2,320 • Slice Thickness (helical Mode): 0.65mm – 10mm • Slice Thickness (axial Mode) 0.625 Mm – 10 Mm • Scan Field Of View: 500 Mm • Detector Configuration / Effective Length Of [mm]: Detector Elements In Z-axis (at Isocentre) [mm]: Capable Of 54 X 0.625mm Or Higher E. Dose Management • Must Adhere To Alara Principle • Dose Reporting: Must Be Available • Dose Modulation Technique: Must Be Available • Ecg Dose Modulation: Must Be Available • Pediatric-specific Dose Control: Must Be Available • Filters: Must Be Available F. Image Reconstruction • Must Have Workflow And Operational Efficiency Enhancements Through Automatic Patient Positioning With The Use Of Camera And Ai Or Its Equivalent • Scan Field Of View: 50cm Or Higher • Minimum Dfov: 5.0 Cm • Slice Thickness: 0.625mm Or Thinner • Reconstruction Matrix: Must Have 512x512 And 1024x1024 • Display Matrix: At Least 1024 X 1024 • Must Have Iterative Reconstruction Or Equivalent Technology G. Patient Table / Couch • Horizontal Range: 1740 Mm Or Higher • Horizontal Scannable Range (helical): 1580 Mm Or Higher • Horizontal Speed: 175 Mm/sec Or Faster • Helical Pitch: At Least 1.5 Or Higher • Vertical Movement Range (out Of Gantry): ≤430 To ≥990 Mm Or Manufacturer’s Equivalent • Couch Load Capacity: ≥ 215 Kg • Cradle Travel Accuracy/ Reproducibility (mm): At Least +/- 0.25 H. Main Console And Computer • Console I. Console Type: All-in-one Console Capable Of Scan, Acquisition And Post Processing Ii. Display Monitor: Dual With At Least 19 Inches At 1280 X 1024 Resolution Iii. Console Cabinet For Dust Protection Iv. Console Table And Chair • Console Computer I. Hz / Word Size: At Least 6core, 2ghz Or Manufacturer's Latest Technology Ii. Compatible Operating System Iii. Ram: At Least 64gb Or Manufacturer's Latest Technology Iv. Graphics Card: Nvidia Quadro P620 Or Manufacturer’s Latest Configuration V. Keyboard And Mouse • Data Management I. Total Internal Disk Storage Of At Least 2tb (2,000gb) Storage For System/application, Image And Raw/scan Disk Data Or Manufacturer's Latest Storage Capability Ii. Additional Storage: Cd/dvd Iii. His / Ris Interface Worklist / Dicom Mpps: Must Be Available And Should Integrate In The Current His-ris-pacs Of The Hospital Iv. Dicom Viewer: Support For External Dicom Usb Media And Preference Management Tool To Exchange Preferences Across Users I. Independent Post Processing Workstation (radiologist) • Hardware Type/processor: At Least 6 Core, Minimum 3.0 Ghz Or Manufacturer's Latest Specification • Ram: 32gb Or Higher • Graphics Card: At Least 1 Gb • Os And Applications: At Least One (1) 256 Gb Ssd • Image Storage: At Least Two (2) 512gb Ssd In Raid Configuration For Image Protection And Redundancy • Archival Storage: Internal Dvd Writer Drive For Read/write Of Dicom Cd/dvd Media, Read/write Of Data Export Cd/dvd Data And Service Use (dvd Install) • Display Monitor: Dual Configuration, Minimum 19" Lcd • Keyboard And Mouse J. Clinical Facilities And Applications • The Following Software/ Applications Are, But Not Limited To The Following And Subject To Radiologists’ Need, Especially For Basic And Comprehensive Whole-body Imaging: I. Vessel Analysis Software Ii. Bone Removal/subtraction Software Iii. Ct Cerebrovascular Auto Segmentation, Ct Subtraction Iv. Ct Pv. Dental Software Vi. Thoracic Analysis Software, Lung Disease Assessment Vii. Lung Nodule Analysis Software Viii. Ct Pulmonary Analysis Ix. Calcium Scoring X. Cardiac Plaque Assessment Xi. Advance Coronary Ct/cardiac Capabilities Xii. Tavi / Tavr Planning Software Xiii. Myocardial Defect Assessment Xiv. Comprehensive Cardiac Function Analysis Xv. Advance Oncology Software / Ct Lesion Analysis Xvi. Hepatic Liver Analysis Software / Ct Liver Analysis Xvii. Ct Colon Analysis / Virtual Colonoscopy Xviii. Virtual Bronchoscopy Xix. Image Fusion Software With Other Modalities Xx. Dental Scan Software Xxi. Stroke Management / Application Software For Hemorrhagic And Ischemic Infarct Or Its Equivalent Xxii. Must Reduce Metal Artifacts And Improve Image Quality While Preserving Body Structural And Anatomic Details. • The Software/applications Should Be Latest And Capable Of Being Constantly Upgraded To Meet Future Development In Ct Imaging For At Least The Next Ten (10) Years, Without Any Additional Cost. K. Others • Set Of Patient Restraints • Patient Positioning Tools • Water Phantom For Calibration And Testing • Lead Glass For The Control Room • Lead Lining For The Examination Room • System Operator Manual • Software Operator Manual • Must Have Local Installation Of The Same Model In At Least 2 Public/government Hospitals In The Philippines Erfusion Analysis, Ct Volume Perfusion • Must Have Principal Local Presence For After Sales And Support L. Air Conditioning System • Two (2) Units Appropriate Air Conditioning System For The Ct Room/scanning Room. • One (1) Unit Appropriate Air Conditioning System For The Equipment Room. M. Warranty Period • Three (3) Years Comprehensive Warranty On Parts And Service For The Ct Machine N. Trainings • At Least Two (2) Weeks Training Abroad With Certification For At Least Four (4) Radiologists • Unlimited On-site Training For Radiologist Technologists, With Certification • At Least Two (2) Weeks Training With Certificate For Two (2) Biomed Engineers And One (1) Health Physicist For Basic Troubleshooting, Preventive Maintenance And Calibration O. Certification That The Brand Being Offered Is In The Local And International Markets For The Part Ten (10) Years; P. Certification That The Same Brand And Model Being Offered Has At Least Two (2) Local Installations In Government Tertiary Hospitals In The Philippines, Within The Past Five (5) Years; Q. Certificate That The Principal Manufacturer Have Their Office In The Local Market For More Than Ten (10) Years (bir Or Sec Registration Certificate To Be Submitted); R. One (1) Modular Ups Each Of 90 Kva To Supply The Gantry, Chiller And Workstation; S. One (1) A1 Pannel Board Supply, Delivery, Installation, Testing And Commissioning Of Brand-new Mri-compatible And Ct-compatible Accessories / Machine (abc: Php10,000,000.00) A. One (1) Unit Mr Compatible Anesthesia Machine With Ventilator A. Must Be Approved To Use With 1.5 Scanners, At Least 1000 Gauss B. Must Have Gauss Meter Monitoring C. Designed Specifically For Use In An Mri Environment D. Electronic Touchscreen Ventilator E. Standard Six Ventilation Modes, And Support For Spontaneous Breathing Patients F. Total System Compatibility G. Compact Footprint, Optimum Maneuverability H. Two Station Selectatec Compatible Backbar I. With 1 Sevoflurane Vaporizer Selectatec Compatible Stability K. Enclosed Construction – No Hidden Storage Areas L. Illuminated Workspace B. One (1) Unit Mr Compatible Patient Monitor A. Performs Patient Monitoring In An Mri Environment Including All Necessary Vital Parameters During Anesthesia B. The System Is Designed For All Patients: Adults, Children And Neonates C. Compatible With Mri Systems From Any Manufacturers That Have A Field Strength At Least 1.5 Tesla D. Wireless Ecg And Spo2 Sensors E. Color Touchscreen C. One (1) Unit Mr Compatible Power Injector D. One (1) Ct Dual/double Barrel Power Injector E. One (1) Unit Mr Compatible Bp Apparatus For Pediatrics And Adults F . One (1) Unit Mr Compatible Stethoscope For Pedia And Adult G. Two (2) Mr Compatible Wheelchairs H. Two (2) Mr Compatible Iv Stand I. One (1) Mr Compatible Stretcher/gurney J. One (1) Set Mr Compatible Cctv System For Patient Observation K. One (1) Mr Compatible Fire Extinguisher L. One (1) Ct Room Fire Extinguisher M. One (1) Mr Compatible Flexible Patient Transfer Board N. Two (2) Hand-held Metal Detector O. Two (2) Units Multifunctional Printer P. One (1) Mr Compatible O2 Outlet And Sunctipon System Q. One (1) Unit Mr Compatible Music / Audio System With Ear Plugs And Headset Covers And With Intercom System R. One (1) Unit Mr Compatible Oxygen Monitor S. One (1) Mr Coil Cabinet T. Two (2) Units Thermohygrometer With Data Logger U. Two (2) Pcs. Lead Aprons V. Two (2) Pcs. Gonadal Shield W. Two (2) Pcs. Thyroid Shield X. Four (4) Pcs. Hand Gloves Y. Two (2) Pcs. Eye Goggles Z. Ten (10) Microsoft Licenses Aa. One (1) Unit Of M3-chip Laptop, Or Latest Ios With At Least 128gb Unified Memory Bb. Ten (10) Stainless Hospital Waiting Area Chairs Cc. Two (2) Units Hot And Cold-water Dispenser Dd. Two (2) Pcs Wooden Bulletin Boards Ee. Two (2) Units Cd/dvd Dicom Reader And Burner Civil Works For Medical Imaging Department Proposed Medical Imaging Department Equipment Rooms Terms Of Reference For The Proposed Medical Imaging Department Equipment Rooms Objective The Las Piñas General Hospital And Satellite Trauma Center Aims To Renovate Its Medical Imaging Department To Enhance Patients’ Outcomes, Improve Diagnostic Services And Provide A Safer And More Efficient Environment For Both Patients And Healthcare Professionals. The Main Purpose Of This Tor Is To Assist The Contractor In Submitting A Bid Offer To Lpgh&stc That Will Satisfy The Hospital’s Requirements At The Most Feasible, Possible Time And Within The Specified Budget. This Document Aims: 1. To Provide A Background Information Regarding The Preparation And Submission Of The Proposed Project To Contractor. 2. To Provide A Background Information Regarding The Proposed Project Which Should Be Handled In The Shortest Possible Time, At An Acceptable Quality And Performance To The Contractor 3. To Outline The Work Of The Contractor That Has To Be Performed Under The Terms Of Its Contract. I. Project Description A) Project Name Procurement Of Infrastructure Project For The Proposed Medical Imaging Department Equipment Rooms End User: Medical Imaging Department Of Lpgh&stc Floor Area : ±300 Square Meters B) Implementing Agency: Las Pinas General Hospital And Satellite Trauma Center Located At Diego Cera Avenue, Bernabe Compound, Pulang Lupa I, Las Pinas City. Ii. Approved Budget And Duration Of Contract The Contract For The Proposed Project Shall Be Within A Period Of One Hundred Fifty (150) Calendar Days Upon Receipt Of Notice To Proceed And With An Approved Project For The Contract Of Eighteen Million Nine Hundred Twenty-five Thousand Five Hundred Fifty-seven Pesos And 80/100 (php 18,925,557.81). Iii. General Conditions 3.1 The Contractor Shall Supply Labor, Materials, Equipment And Other Necessary Items For The Project With The Following Conditions: 3.1.1 A Building Permit (if Necessary) Must Be Secured From The Building Official Of Las Pinas City And Submitted To Las Pinas General Hospital And Satellite Trauma Center Located At Diego Cera Avenue, Bernabe Compound, Pulang Lupa I, Las Pinas City Prior To Construction. 3.1.2 Conduct Ocular Inspection/site Inspection Prior To The Submission Of Bid. 3.1.3 3.1.4 The Plans, Detailed Drawings, Specifications, Detailed Bill Of Quantities, Terms Of Reference, Contract Agreement And Other Bid Documents Shall Be Considered As Complementing Each Other, So That What Is Mentioned Or Shown In One, Although Not Mentioned In The Other, Shall Be Considered As Appearing On Both. In Case Of Conflict Between The Two, The Same Should Be Referred To The Technical Working Group (twg) For Resolution With The Approval Of The Head Of The Procuring Entity (hope) Of Las Pinas General Hospital And Satellite Trauma Center. 3.1.4 The Construction Shall Be Finished With First Class Workmanship To The Satisfaction Of The Lpgh And Stc. 3.1.5 The Construction Works Shall Conform To The Requirements Of The National Building Code, National Structural Code Of The Philippines, Philippine Mechanical Code Of The Philippines, Philippine Electrical Code, Philippine Electronics Code, Code Of Professional Practice And Other Related Pertinent Practices, Codes In The Philippines As Well As The Local Rules, Regulations And Ordinances Of The City Government And Must Be Acceptable To The Las Pinas General Hospital And Satellite Trauma Center. 3.1.6 Itemized Of Bill Quantities 3.1.6.1 The Items, Description And Quantities Given On The First Three Columns Of The Bill Of Quantities Under Section Viii, Guides Only To The Bidder Interpreting The Plans And Technical Specifications. The Las Pinas General Hospital And Satellite Trauma Center, Bac And Twg Is Not Responsible For Any Mistakes, Inaccuracies, Duplications Or Omissions In This List Of The Bill Of Quantities Which Shall Never Be A Basis For Additions Nor Deletions To The Scope Of Work. Only The Entries Of The Bidder On The Last Three Columns Consisting Of His Own Take Off Quantities From The Plans And Technical Specifications And His Unit Cost And Corresponding Sums Shall Be Considered. 3.1.6.2 The Bill Of Quantities Prepared By The Bidder Cannot Be Used As Basis For Claims For Any Extra Work, But May Only Be Used Solely By The Las Pinas General Hospital And Satellite Trauma Center, Bac And Twg As Aid In Judging If Bid Is A Responsive Bid. 3.1.6.3 The Unit And Total Bid Prices Must Include All Direct And Indirect Cost/ Expenses Such As Overhead, Contingencies And Miscellaneous (ocm); Profit, Plus The Corresponding Value Added Tax And Other Obligations Of Any Kind Under Which The Contract Must Be Borne By The Contractor Since They Are Necessary To Install, Construct And Complete The Whole Of The Contract In Accordance With The Bid Documents. 3.1.7 All Permits And Corresponding Fees As May Be Assessed By The Local Government Unit/regulating Agencies Shall Be On The Account Of The Contractor. 3.1.8 The “green And Safe Health Facilities Manual 1st Edition” Shall Also Form Part Of This Tor Which Comprises Efforts Of The Health Sector That Contribute To The Attainment Of The Country’s Goals Towards Sustainable Development. 3.1.9 The Administrative Order No. 2024- “guidelines For The Implementation Of Projects Funded Under The Health Facility Enhancement Program (hfep) Fiscal Year 2024” Shall Be Part Of This Tor That Serves As A Guide For The Proper And Systematic Implementation And Monitoring Of All Projects Funded Under The Hfep Gaa Fy2024. 3.1.10 The Separate “scope And Specifications” Shall Form Part Of This Tor That Will Serve As Basis To Define The Requirements For Project Execution Regarding Installation, Materials, Products, Procedures, And Quality Aspects. The Scope And Specifications Shall Govern The Coverage And Methods Of Construction And The Kind Of Materials To Be Used For The Proposed Project Shown In The Plans And Detailed Drawings. Iv. Scope Of Works 4.1 Work/operation Plan 4.1.1 The Contractor Shall Submit The Project Work Plan (pertcpm, Gantt Chart, S-curve, Detailed Construction Methods, Project Execution Plan, Construction Safety Health Program, Procurement Plan And Manpower And Equipment Schedule) Consisting Of The Specific Work Activities And Dates Within Ten (10) Calendar Days Upon Receipt Of Notice To Proceed. 4.2 Contractual Scope Of Works 4.2.1 The Contractor Shall Provide Professional Services And Other Support Services Necessary For The Implementation Of The Complete Construction Of The Proposed Project. 4.2.2 The Contractor Shall Be Responsible For Providing Complete Professional Services For All Aspects Of The Proposed Project Including, But Not Limited To The Following: 4.2.2.1 Perform Data Collection And Field Investigation To Determine Actual Site Conditions 4.2.2.2 Submit Construction Methodology Prior To The Start Of The Renovation And After Ocular Inspection And Coordination With Lpgh&stc. 4.3 Construction Phase 4.3.1 The Contractor Shall Prepare, Secure, Submit, Process All Necessary Documents (permits, Clearance, Plans, Etc.) And Payment Of All Assessed Fees And Other Incidental Expenses Related Thereto As May Be Required By The Local Government Unit, Utility Firms (electric Cooperative, Local Water Utilities Administration, Pldt, Etc.) And Other Regulating Agencies. 4.3.2 The Contractor Shall Undertake The Proposed Medical Imaging Department Equipment Rooms And Its Required Infrastructures And Appurtenances In Accordance With The Approved Plans And Designs As Follows: 4.3.2.1 Architectural Plans 4.3.2.2 Other Engineering Plans 4.3.2.3 Project Specifications 4.3.3 The Contractor Shall Designate One (1) Project Manager, One (1) Professional Mechanical Engineer And One (1) Professional Electrical Engineer Who Shall Work During The Construction Period/duration Of The Contract And Shall Only Report On Site When Needed During Project Implementation Or Weekly Infrastructure Meeting. 4.3.4 The Contractor Shall Designate One (1) Project Engineer (civil Engineer), One (1) Project Architect, One (1) Electrical Engineer, One (1) Mechanical Engineer (mepfs), One (1) Safety Officer 2 (so2), One (1) Qa/qc Engineer And One (1) Document Controller/admin Who Shall Work Full Time During The Construction Period/duration Of The Contract And Shall Be In Charge Of The Construction Work And Perform The Following But Not Limited To: 4.3.4.1 Coordinate With The Las Pinas General Hospital And Satellite Trauma Center And Engineering And Facilities Management (efm) Regarding The Implementation Of The Construction Project. 4.3.4.2 Schedule, Oversee And Monitoring The Day-to-day Construction Works. 4.3.4.3 Coordinate, Address And Resolve All Concern/s Of Nearby Buildings And Structures Relative To The Construction And Related Services As Required By Lgu And Other Regulating Agencies. 4.3.4.4 Prepare Daily Activity Reports, Weekly And Monthly Accomplishment Reports Supported With Progress Photographs (geotagged) And S-curves To Monitor Actual Progress Status Report And To Be Used As Basis For Progress Billing. 4.3.4.5 Conduct A Weekly Construction Coordination Meeting With The Las Pinas General Hospital And Satellite Trauma Center, Twg And Infrastructure Committee During Which A Weekly Progress Report On All Activities For The Previous Week Will Be Submitted. 4.3.5 The Contractor Shall Be Responsible In Conducting The Necessary Tests Required. For The Structural Elements, Standard Testing For Concrete And Reinforcing Bars Are Required. The Testing Laboratory Must Be Accredited By Dpwh And Must Be Witnessed By Any Authorized Representatives Of The Lpgh&stc And The Consultant. 4.3.6 The Contractor Shall Be Responsible For Restoring Walls And Structures Of Adjacent Properties At The Vicinity Of The Project Site As May Be Affected During The Construction Works, If Any. 4.3.7 The Contractor Shall Provide All The Necessary Safety Equipment Such As Board- Up And Closure Signages, Mechanical Blowers To Collect Dust During Surface Preparation And Other Required Equipment To Make Sure That The Operations Of The Hospital Will Not Be Affected. 4.3.8 The Contractor Shall Be Responsible In The Hauling And Disposal Of Debris And Other Construction Wastes. 4.3.9 The Contractor Shall Provide All Other Works And/or Materials Not Included In This Terms Of Reference/scope And Specifications/bill Of Quantities But Are Essential For The Satisfactory Completion Of The Project At No Additional Cost To The Las Piñas General Hospital And Satellite Trauma Center. 4.3.10 Other Works Due To The Contractor Are: 4.3.10.1 Supply And Installation Of Accessories 4.3.10.2 Waterproofing Works At Cssd/autoclave Room 4.3.10.3 Restoration, Repair And Rectification Of Cistern Area And Vacuum Room 4.4 Electric And Water Consumption For The Duration Of The Contract Shall Be For The Account Of The Contractor. Contractor To Provide Water And Electric Meter. V. Post Construction Documentation 5.1 The Contractor Shall Submit The Following Project Documentations Within Thirty (30) Calendar Days From The Completion Of The Project. 5.1.1 As-built Plans Duly Signed And Dry-sealed By The Concerned Design Architect And Engineers With His/her Valid Registration/professional License Number, Date Of Registration And Current Ptr Number Affixed/stamped On Every Page/sheet Of The Document Of The Following: • Architectural Plans • Mechanical And Fire Protection Plans • Plumbing And Sanitary Plans • Auxiliary Plans • Other Relative Plan 5.1.2 All Plans And Documents Shall Be Delivered In Sets As Follows: 5.1.2.1 One (1) Set Original Copies, Scaled 1:100 Meter Prepared In Cadd Format, Printed/plotted In Tracing Paper. 5.1.2.2 Five (5) Sets Blue Prints Copies For Each Plan 5.1.2.3 One (1) Set Soft Copy (cadd And Pdf) In Flash Drive. 5.1.2.4 Certificate Of Occupancy (if Necessary) 5.1.2.5 Certificate Of Warranty For One (1) Year To Cover The “one – Year Defects Liability Period” Of The Contractor. Form Of Warranty Shall Be In Accordance With The Provisions Of The “revised Irr Of Republic Act. No. 9184, Otherwise Known As The Government Procurement Act”. 5.1.2.6 Warranty Certificate For All The Equipment Supplied Based On The Warranty Duration Stated In The Specifications Document. 5.1.2.7 Other Documents Processed And Issued In Favor Of The Las Pinas General Hospital And Satellite Trauma Center During The Construction Periods (i.e., Inspection Reports, Building Permits, Official Receipts, And Related Documents Other Than Stated In Section 4.3.1). Vi. Post Construction Warranties 6.1 The Contractor Shall Also Provide Within The One (1) Year Warranty Period At No Additional Cost To The Las Pinas General Hospital And Satellite Trauma Center All Replacement Units/parts With The Same Quality, Standard And Specification For All Other Deliverables. 6.2 The Contractor Shall Provide Warranties On Equipment And Other Deliverables As What Stated In The Scope And Specification. Vii. Safety Enclosures 7.1 Provide Safety Nets (enclosures, Shielding, Coverings, Warning Device, Keep-off Limits Signs, Etc.) Upon The Start Of The Project To Ensure Protection Of The General Public And Preservation Of Damage To Properties. Viii. Provision Of Storage & Material Handling 8.1 The Contractor Shall Store Their Materials, Equipment And Tools Only, In One Place Of The Hospital Premises. The Area Shall Be Coordinated With The Chief Administrative Officer Of Las Pinas General Hospital And Satellite Trauma Center And Efm. It Shall Be Kept Neat And Clean All The Times. Any Damage Thereto Or To The Surrounding Area Arising From Any Accident, Etc. Shall Be Repaired And/or Restored To Its Original Condition. Likewise, Extra Care Shall Be Taken In Storage Of Hazardous Chemicals In Order To Avoid Accident, Explosion And/or Fires. The Job Site Shall Be Cleaned At The End Of Every Working Day. 8.2 Provisions For Securing And Safekeeping The Stored Materials, Tools And Equipment During The Construction Project Shall Be For The Account Of The Contractor. Ix. Clearing Of Site The Contractor Shall Clean The Whole Area By Removing Debris, Discards, Excesses And Spillage And Shall Leave The Entire Premises Free From Rubbish Caused By Their Work To The Satisfaction Of The Las Pinas General Hospital And Satellite Trauma Center At No Extra Cost. X. Service Level Agreement Las Pinas General Hospital And Satellite Trauma Center Shall Maintain A Service Level Agreement (sla) With The Contractor, With Provisions For Liquidated Damages For Their Non-compliance. Xi. Warranties Of The Contractor 11.1 The Contractor Warrants That It Shall Conform Strictly To The Terms And Conditions Of This Terms Of Reference. 11.2 The Contractor Warrants, Represents And Undertakes Reliability Of The Service And That Their Manpower Complements Are Hardworking, Qualified, Reliable And Dedicated To Do The Service Required To The Satisfaction Of The Las Pinas General Hospital And Satellite Trauma Center. It Shall Employ Well-behaved And Honest Employees. They Shall Wear Id And Proper Company Uniform When Working Within The Construction Site. It Shall Not Employ Las Pinas General Hospital And Satellite Trauma Center Employees And Their Relatives Within The Fourth Civil Degree Of Consanguinity Or Affinity To Work In Any Category Whatsoever. 11.3 The Contractor Shall Comply With The Laws Governing Employee’s Compensation, Philhealth, Social Security And/or Labor Standard And Other Laws, Rules And Regulations Applicable To Its Personnel Employed By The Contractor On Account Of Contracted Services. The Contractor Shall Pay Its Personnel Not Less Than Minimum Wage And Other Benefits Mandated By Law. 11.4 The Contractor In Performance Of Its Services Shall Secure, Maintain At Its Own Expense All Registration, Licenses Or Permits Required By National Or Local Laws And Shall Comply With The Rules, Regulations And Directives Of Regulatory Authorities And Commissions. The Contractor Undertakes To Pay All Fees Or Charge Payable To Any Instrumentality Of Government Or To Any Other Duly Constituted Authority Relating To The Construction Project At No Cost To Las Pinas General Hospital And Satellite Trauma Center. 11.5 The Contractor’s Personnel Shall Take All Necessary Precautions For The Safety Of All Persons And Properties At Or Near Their Area Of Work And Shall Comply With All The Standard And Established Safety Regulations, Rules And Practices. A Construction Safety And Health Program Approved By The Dole Must Be Submitted By The Contractor Including The Deployment Of A Full-time Safety Officer On Site. 11.6 The Contractor Shall Coordinate With Any Authorized And/or Designated Las Pinas General Hospital And Satellite Trauma Center Personnel And E&fm In The Performance Of Their Jobs. 11.7 The Contractor Shall Be Liable For Loss, Damages, Or Injury As May Be Due Directly Through The Fault Or Negligence Of Its Personnel. It Shall Assume Responsibility Thereof And The Las Pinas General Hospital And Satellite Trauma Center Shall Be Specifically Released From Any Responsibility Arising Therefrom. 11.8 The Contractor Shall Neither Assign, Transfer, Pledge, Nor Subcontract Any Part Or Interest Therein. 11.9 The Contractor Shall Be Solely Liable To Its Suppliers And The Las Pinas General Hospital And Satellite Trauma Center Shall Be Free From Any Liabilities That May Arise From Contractor-supplier Agreement. Xiii. Contractor’s Qualification 13.1 The Minimum Requirements For The Contractor Are As Follows: 13.1.1 Must Be At Least Five (5) Years In The Construction Business. 13.1.2 Must Have Completed At Least Three (3) Solely Infrastructure Projects In A Hospital. 13.1.3 Must Have At Least Two (2) Certificate Of Very Satisfactory Rating From Client Hospital Signed By The Medical Center Chief Or Its Equivalent For The Above-mentioned Infrastructure Projects. 13.1.4 Must Have An Appropriate Pcab License Of At Least Small B Category
Contact
Tender Id
bdea1a72-3dde-3f92-8be0-ec7a8e8c63beTender No
10747460Tender Authority
Las Pi as General Hospital And Satellite Trauma Center ViewPurchaser Address
-Website
notices.philgeps.gov.ph