Adela Serra Ty Memorial Medical Center Tender
View complete overview of Adela Serra Ty Memorial Medical Center Tender
Adela Serra Ty Memorial Medical Center Tender
Opening Date
22 Jun 2022Closing Date
12 Jul 2022Tender Amount
PHP 1,20,86,500 (USD 2,14,078)Costs
Summary
Procurement Of Various Laboratory Supplies And Reagents Ib No. 2022-07-12 (17) , Laboratory Supplies And Equipment ,adela Serra Ty Memorial Medical Center
Description
Description Republic Of The Philippines Department Of Health Adela Serra Ty Memorial Medical Center Capitol Hills, Tandag City, Surigao Del Sur Telefax No. 086-211-4306, E-mail Add: Astmmc_hbac@yahoo.com.ph Invitation To Bid For The Procurement Of Various Laboratory Supplies And Reagents (main Laboratory) Ib No. 2022-07-12 (17) 1. The Adela Serra Ty Memorial Medical Center, Using A Multi-year For A Duration Of (3) Three Year Framework Agreement, Intends To Apply The Sum Of Twelve Million Eighty Six Thousand Five Hundred Pesos Only Php 12,086,500.00 Being The Abc To Payments Under The Contract For Procurement Of Various Laboratory Supplies And Reagents. Bids Received In Excess Of The Total Cost Per Item Or Per Lot Shall Be Automatically Rejected. 2. The Adela Serra Ty Memorial Medical Center Now Invites Bids For Procurement Of Various Laboratory Supplies And Reagents. Delivery Of The Goods After Issuance Of A Call-off Or Any Date Determined By The Pe. Bidders Should Have Completed, Within 5 Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From Adela Serra Ty Memorial Medical Center And Inspect The Bidding Documents At The Address Given Below During 8:00am To 5:00pm, Monday To Friday. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On June 22, 2022 To July 12, 2022 From The Given Address Below. The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees Twenty Five Thousand Pesos Only [php 25,000.00]. 6. The Adela Serra Ty Memorial Medical Center Will Hold A Pre-bid Conference On June 30, 2022; 9:00am At Avr, 3rd Floor, Opd Bldg, Astmmc, Tandag City And Or Through Video Conferencing Or Webcasting Via Meet.google.com/cin-khyp-rdr, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address Indicated Below, On Or Before 9:00am; July 12, 2022. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On 9:00am; July 12, 2022at The Given Address Below And Or Through Video Conferencing Or Webcasting Via Meet.google.com/cin-khyp-rdr, Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. The Adela Serra Ty Memorial Medical Center Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. For Further Information, Please Refer To: Bac Office, 2nd Floor Opd Bldg. Astmmc, Tandag City, Sds, 8300 Tel No. 086-211-4306 Astmmc_hbac@yahoo.com.ph Carolina E. Bendanillo, Dmd Bac Chairperson Lot Number Description Quantity Unit Unit Price Total Delivered, Weeks/months Hematology Lot 1 Winning Bidder: > Must Provide A Fully Automated Hematology 5-part Analyzer For Wbc, Rbc, And Platelet For Free. > Must Provide Back-up Machine To Be Used In Case The Machine Breaks Down To Avoid Performing Cbc Manually That Will Affects The Turnaround Time Of Testing. > Analyzer Should Be Delivered Complete With Its Accessories (ups, Keyboard, Printer, Avr, Etc.) > Free Of Charge Technical Services Of Company Engineer Which Must Be Available And Responsive To Any Of The Problems Or Concerns Of The Machine 24/7, Conduct Regular Monthly Machine's Calibration And Preventive Maintenance. > Machine Must Have A Built-in Quality Control Program And Lis Ready. > Prompt Replacement Of Another Unit Of Analyzer Or Defective Parts In Case Of Breakdown Shall Be Done Within 24-48 Hours. > Corresponding Sets Of Reagent Must Be Delivered Quarterly. In The Event Available Supply In Our Office Is Short Before The Scheduled Delivery, Winning Bidder Must Be Capable Of Supplying The Needed Goods Upon Notice. > Sets Of Quality Control Reagents (low, Normal And High) Should Be Provided For Free Which Should Be Delivered Monthly Or As Needed. > Quantity Of Reagents Must Be Delivered In A Quarterly Basis Or Staggered Scheme Or Upon The Request Of The End-user. > Payments Will Be Issued Per Delivery Of Reagents. > Reagents Delivered Must Be 18 Months From The Expiration Date, A Guarantee Letter Of Replacement May Be Issued For Less Than 18 Months Reagents And Supplies. > A Framework Agreement For A 3-year Contract Shall Be Made. Hence, Renewable Yearly After Evaluation Report And Deliberation Among The End Users. Machine Specifications: >analytical Principle/system Description: Wbc & Differential: Flow Cytometry Fluorescence Methodology Platelets: Reading Is Optical Analysis Hgb: Cyanide-free Sls Method >parameters: Wbc, Rbc, Hgb, Hct, Mcv, Rdw, Plt, Mpv, Retc >throughput (cbc + Differential): At Least 60 Tests/hour >automatic Close Tube Testing >can Be Manually Feed To Testing >sample Volume: At Least 150 Ul >minimal Amount Of Sample Using Capillary Mode >with Autoloader For Multisample Testing >lis Ready 5-part Hema Analyzer Diluent Set (wbc Lyse, Cleaners, Etc.) 80 Box 27,000.00 2,160,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe Lot 2 Winning Bidder:> Must Provide An Iso-certified Semi-automated Coagulation Analyzer For Free.> Reagents Must Be Compatible With Machine Provided.> Reaction Cuvettes Must Be Provided For Free.> Analyzer Should Be Delivered Complete With Its Accessories (ups, Keyboard, Printer, Avr, Etc.) > Quantity Of Reagents Must Be Delivered In A Quarterly Basis Or Staggered Scheme Or Upon The Request Of The End-user. > Payments Will Be Issued Per Delivery Of Reagents. > Reagents Delivered Must Be 18 Months From The Expiration Date, A Guarantee Letter Of Replacement May Be Issued For Less Than 18 Months Reagents And Supplies. > A Framework Agreement For A 3-year Contract Shall Be Made. Hence, Renewable Yearly After Evaluation Report And Deliberation Among The End Users. > Free Of Charge Technical Services Of Company Engineer Which Must Be Available And Responsive To Any Of The Problems Or Concerns Of The Machine 24/7, Conduct Regular Monthly Machine's Calibration And Preventive Maintenance. > Prompt Replacement Of Another Unit Of Analyzer Or Defective Parts In Case Of Breakdown Shall Be Done Within 24-48 Hours. > Machine Must Have A Built-in Quality Control Program And Lis Ready. > Supplier Must Shoulder Connectivity Fee/charges For Lis Services And Coordinate With Astmmc Lis Provider For The Lis Connection. > Sets Of Quality Control Reagents (low, Normal And High) Should Be Provided For Free Which Should Be Delivered Monthly Or As Needed. Aptt Reagent (5 Ml/bot X 6 Bot/box) 6 Box 18,000.00 108,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe Calcium Chloride (5 Ml/bot X 6 Bot/box) 6 Box 18,000.00 108,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe Clinical Chemistry Lot 3 Winning Bidder Responsibilities: > Must Provide And Install An Iso Certified, Fully Automated Chemistry Analyzer For Free Of Use. > Free Of Charge Technical Services Of Company Engineer Which Must Be Available And Responsive To Any Of The Problems Or Concerns Of The Machine 24/7, Conduct Regular Monthly Machine's Calibration And Preventive Maintenance. >participating Bidder Must Have An Existing Machine Installed In The Laboratory. > Machine Provided Must Be Lis Ready. > Supplier Must Shoulder Connectivity Fee/charges For Lis Services And Coordinate With Astmmc Lis Provider For The Lis Connection. > In Case Of Breakdown, Prompt Replacement (not Later Than 48 Hrs Upon Notice Of Breakdown) With Another Unit Of Machine Or Parts. > Must Provide A Back-up Machine To Serve The Purpose, If Not Must Shoulder Expenses Incurred For The Sending Out Of Samples To Other Laboratories Due To Machine Breakdown And Unresponsiveness Of Supplier. > National Reference Laboratory Result Of Eqas Must Be Excellent For The Past 2 Years. Machine Should Be Officially Enrolled Or Have Record At Qcnet.com. It Should Have Multiple Installation And Has Been Proven To Provide Satisfactory Laboratory Test Results. > Meet Laboratory Quality Objective Performance #1, The Turnaround Time (tat) To Release Result After 2 Hours And Can Run All Tests 24 Hours A Day, 7 Days A Week. > Must Provide And Free Of Charge (foc): - All Consumables Needed For The Machine To Function - Calibrators - Computer Sets, Ups, Avr, Printer - Calibration & Preventive Maintenance - Any Parts Or Accessories Of Machine > Incorporated With Free Water Station Machine W/ Built In Water Filtration System To Provide Unlimited And Uninterrupted Distilled Water Supply For The Machine Consumption; In Case That The Built-in Water Station Cannot Serve Its Purpose, Distilled Water Can Be Provided By The Laboratory But Cost Incurred Shall Be Charged Against The Supplier And Supplier's Performance Will Be Affected During The Annual Performance Evaluation Report From The End Users. > Quantity Of Reagents Must Be Delivered In A Quarterly Basis Or Staggered Scheme Or Upon The Request Of The End-user. > Payments Will Be Issued Per Delivery Of Reagents. > Reagents Delivered Must Be 18 Months From The Expiration Date. > A Framework Agreement For A 3-year Contract Shall Be Made. Hence, Renewable Yearly After Evaluation Report And Deliberation Among The End Users. Machine Specifications Of Fully Automated Chemistry Analyzer: > Floor Type Machine >analytical Principle/system Description: Photometric/potentiometric/turbidimetric/clia/spectrophotometry >test Throughput Per Hour: 400-800 >sample Type For Analysis: Whole Blood/serum/plasma/csf Or Other Fluids/urine >sample Tube Size Used For Analysis: 13x100mm & 12x75mm >sample Capacity: At Least 60 Sample Positions >machine Water Requirements: With Machine For Water System Necessary To Its Operation >machine Quality Assurance: Autocalibration, Auto-qc, Auto Westgard Rules/levy Jennings Plotting Of Real Time Qc >machine Diagnostics System & Services: Online/remote Access/ With Color Touchscreen Monitor >machine Patient Data Storage: At Least 100,000 >stat Samples Priority Placement/program >programmed With Automatic Sample Dilution Winning Bidder Responsibilities: > Must Provide And Install An Iso Certified, Fully Automated Chemistry Analyzer For Free Of Use. > Free Of Charge Technical Services Of Company Engineer Which Must Be Available And Responsive To Any Of The Problems Or Concerns Of The Machine 24/7, Conduct Regular Monthly Machine's Calibration And Preventive Maintenance. >participating Bidder Must Have An Existing Machine Installed In The Laboratory. Glucose (at Least 300 Tests) 10 Cart/box/bottle/cassette 10,000.00 100,000.00 Total Cholesterol (at Least 300 Tests) 10 Cart/box/bottle/cassette 10,000.00 100,000.00 Triglyceride (at Least 300 Tests) 10 Cart/box/bottle/cassette 20,000.00 200,000.00 Hdl Direct (at Least 360 Tests) 10 Cart/box/bottle/cassette 21,000.00 210,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe Creatinine (at Least 375 Tests) 20 Cart/box/bottle/cassette 15,000.00 300,000.00 Bun (at Least 260 Tests) 10 Cart/box/bottle/cassette 10,000.00 100,000.00 Bua (at Least 300 Tests) 10 Cart/box/bottle/cassette 12,000.00 120,000.00 Sgpt (at Least 275 Tests) 10 Cart/box/bottle/cassette 15,000.00 150,000.00 Sgot (at Least 275 Tests) 10 Cart/box/bottle/cassette 15,000.00 150,000.00 Total Protein (at Least 360 Tests) 5 Cart/box/bottle/cassette 11,000.00 55,000.00 Albumin (at Least 260 Tests) 5 Cart/box/bottle/cassette 15,000.00 75,000.00 Total Bilirubin (at Least 275 Tests) 5 Cart/box/bottle/cassette 12,000.00 60,000.00 Direct Bilirubin (at Least 275 Tests) 5 Cart/box/bottle/cassette 12,000.00 60,000.00 Calcium (at Least 300 Tests) 9 Cart/box/bottle/cassette 13,000.00 117,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe Magnesium (at Least 200 Tests) 8 Cart/box/bottle/cassette 10,000.00 80,000.00 Lipase (at Least 150 Tests) 9 Cart/box/bottle/cassette 20,000.00 180,000.00 Amylase (at Least 100 Tests) 9 Cart/box/bottle/cassette 10,000.00 90,000.00 Alkaline Phosphatase (at Least 300 Tests) 5 Cart/box/bottle/cassette 30,000.00 150,000.00 Lactate Dehydrogenase (at Least 260 Tests) 5 Cart/box/bottle/cassette 30,000.00 150,000.00 Control 1 - Low (12 Bot. X 5 Ml Per Box) 1 Box 19,000.00 19,000.00 Control 2 - Normal (12 Bot. X 5 Ml Per Box) 1 Box 19,000.00 19,000.00 Control 3 - High (12 Bot. X 5 Ml Per Box) 1 Box 19,000.00 19,000.00 Microbiology Lot 4 Winning Bidder Responsibilities: > Must Provide For Free An Iso-certified Fully-automated Culture Identification And Susceptibility Test Machine > Free Of Charge Technical Services Of Company Engineer Which Must Be Available And Responsive To Any Of The Problems Or Concerns Of The Machine 24/7, Conduct Regular Monthly Machine's Calibration And Preventive Maintenance. > Machine Should Be Delivered Complete With Its Accessories (ups, Keyboard, Printer, Avr, And Any Other Needed Accesory, Etc.) >preferrably With Remote Connectivity For Updates And Fast Troubleshooting > Capable Of A Prompt Replacement Of Another Unit Of Machine / Analyzer Or Replacement Of Defective Parts In Case Of Breakdown (not Later Than 48 Hours From Bug Down) > Machine Provided Must Be Lis Ready. > Supplier Must Shoulder Connectivity Fee/charges For Lis Services And Coordinate With Astmmc Lis Provider For The Lis Connection. > Quantity Of Reagents Must Be Delivered In A Quarterly Basis Or Staggered Scheme Or Upon The Request Of The End-user. > Payments Will Be Issued Per Delivery Of Reagents. > Reagents Delivered Must Be 18 Months From The Expiration Date, A Guarantee Letter Of Replacement May Be Issued For Less Than 18 Months Reagents And Supplies. > A Framework Agreement For A 3-year Contract Shall Be Made. Hence, Renewable Yearly After Evaluation Report And Deliberation Among The End Users. Machine Specifications: > With Gold-standard Accuracy For Microorganism Identification And Susceptibility > Enables Simultaneous Processing Of Conventional, Rapid And Specialty Panels On A Single, Automated Platform > Delivers Accurate Emerging Resistance Detection For The Toughes Pathogens, Including Visa, Vrsa And Mrsa > Processes Rapid And Specialty Id Panels For Reduced Turnaround Time > Automated Detection Of Atypical Results For Quick Reporting > Allows Consolidation Of Data From Multiple Testing Systems On Epidemiology Reports > Lis-who Net Configuration And Connection Ready > Automatic Incubation, Test Interpretation And Reagent Control > Easy-to-lock Reagent Bottle Caps > With Level Sensors For Fluid Systems Monitoring > With Large-capacity Reagent And Water Reservoirs For Reduced Maintenance > With Direct Water Connection For Automatic Refill > With Built-in Barcode Scanner > With Real-time Cummulative Statistical Functions > Allow Remote Access By Multiple Users And Real-time Connectivity To Our Existing Lis > Eucast And Clsi Compliant Ast Formulations Available Producing Mic's Based On Reference Clsi And Iso Mic Methods 0.5% N,n Dimethyl-alpha-napthylamide (30 Ml/bot) 2 Bot 4,000.00 8,000.00 0.8% Sulfanilic Acid Rgt A (30 Ml/bot) 2 Bot 4,000.00 8,000.00 5% Alpha Naphthol A (30 Ml/bot) 2 Bot 4,000.00 8,000.00 10% Ferric Chloride (30 Ml/bot) 2 Bot 4,500.00 9,000.00 Anaerobe Rapid Chromo Id (20/box) 3 Box 33,000.00 99,000.00 Barcode Label Paper 2 Roll 18,000.00 36,000.00 Erlichs Reagent (30 Ml/bot) 2 Bot 4,000.00 8,000.00 Esbl Plus Confirmation Panel (20/box) 2 Box 33,500.00 67,000.00 Haemophilus Test Medium (10/box) 1 Bot 13,500.00 13,500.00 Hnid Indole Reagent (30 Ml/bot) 2 Bot 3,500.00 7,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe Hnid Inoculum Broth (60/box) 1 Box 25,000.00 25,000.00 Hnid Panel (20/box) 1 Box 23,500.00 23,500.00 Inoculator D240 (240/box) 5 Box 65,000.00 325,000.00 Inoculum H20 W/ Pluronic (60/box) 12 Box 32,000.00 384,000.00 Kovacs Reagent (30 Ml/bot) 2 Bot 4,000.00 8,000.00 Microstrep Plus 1 (20/box) 3 Box 24,000.00 72,000.00 Mineral Oil A (250 Ml) 2 Bot 15,000.00 30,000.00 Negative Combo 72 (20/box) 27 Box 23,500.00 634,500.00 Peptidase Reagent B (30 Ml/bot) 2 Bot 4,500.00 9,000.00 Positive Id Panel Type 3 (20/box) 10 Box 24,500.00 245,000.00 Positive Mic 33 (20/box) 10 Box 24,500.00 245,000.00 Potassium Hydroxide A 40% (30 Ml/bot) 2 Box 4,000.00 8,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe Prompt Inoculation System (60/box) 5 Box 25,500.00 127,500.00 Rapid Yeast Id 2 Panel (20/box) 2 Box 40,000.00 80,000.00 Rapid Yeast Turbidity Standard 1 Bot 4,500.00 4,500.00 Seal Strips 1 Roll 7,500.00 7,500.00 Sodium Hydroxide (30 Ml) 2 Bot 32,000.00 64,000.00 Sterile Inoculum H20 (60/box) 5 Box 26,500.00 132,500.00 Tray Lids (240/box) 4 Box 36,500.00 146,000.00 Xylene Reagent 2 Bot 3,000.00 6,000.00 Positive Combo (20/box) 20 Box 23,500.00 470,000.00 Lot 5 Winning Bidder Responsibilities: > Must Provide For Free An Iso-certified Fully-automated Blood And Body Fluids Culture Machine That Utilizes Comprehensive Detection Technology > Free Of Charge Technical Services Of Company Engineer Which Must Be Available And Responsive To Any Of The Problems Or Concerns Of The Machine 24/7, Conduct Regular Monthly Machine's Calibration And Preventive Maintenance. > Machine Should Be Delivered Complete With Its Accessories (ups, Keyboard, Printer, Avr, And Any Other Needed Accesory, Etc.) > Preferrably With Remote Connectivity For Updates And Fast Troubleshooting > Capable Of A Prompt Replacement Of Another Unit Of Machine / Analyzer Or Replacement Of Defective Parts In Case Of Breakdown (not Later Than 48 Hours From Bug Down) > Machine Provided Must Be Lis Ready. > Supplier Must Shoulder Connectivity Fee/charges For Lis Services And Coordinate With Astmmc Lis Provider For The Lis Connection. > Quantity Of Reagents Must Be Delivered In A Quarterly Basis Or Staggered Scheme Or Upon The Request Of The End-user. > Payments Will Be Issued Per Delivery Of Reagents. > Reagents Delivered Must Be 18 Months From The Expiration Date, A Guarantee Letter Of Replacement May Be Issued For Less Than 18 Months Reagents And Supplies. > A Framework Agreement For A 3-year Contract Shall Be Made. Hence, Renewable Yearly After Evaluation Report And Deliberation Among The End Users. Machine Specifications: > Capable To Measure Production And Consumption Of All Gases (co2, O2, No2 And H2) > Continuous Monitoring Of Head Space Changes, Both Positive And Negative Pressure As A Direct Result Of Baterial Metabolism And/or Growth > Can Provide Graph Analysis > Bottle Formulation: Aerobic And Anaerobic > Bottles With Direct Draw > With Agitation Technology > With Built-in Quality Control > With Immediate Bottle Recognition > With Rapid Response Time And Greater Accuracy Redox 1 Blood Culture Bottle W/ Connector (50 Bots/box) 75 Box 33,000.00 2,475,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe Redox 2 Blood Culture Bottle W/ Connector (50 Bots/box) 12 Box 33,000.00 396,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe Clinical Microscopy Lot 6 Winning Bidder Responsibilities: > Must Provide For Free A Fully-automated Urine Analyzer That Can Read Simultaneously Both Reagent Strip/chemistry Tests And Urine Sediments. > Must Ensure That Urine Analysis Should Be Examined By Their Fully Automated Machine, Considering The Bulk Of Requests Accepted Every Shift From In And Out Patients. >participating Bidder Must Have Existing Machine Installed In The Laboratory > Must Provide A Fully Automated Urine Analyzer For Free > Must Provide A Back-up Machine To Serve The Purpose. > Must Provide Complete Set Of Reagents, Controls, Calibrators, Distilled Water, Test Tubes And Other Consumables Needed To Generate A Fully Automated Accurate Urinalysis Result > Quantity Of Reagents Must Be Delivered In A Quarterly Basis Or Staggered Scheme Or Upon The Request Of The End-user. > Payments Will Be Issued Per Delivery Of Reagents. > Reagents Delivered Must Be 18 Months From The Expiration Date. > A Framework Agreement For A 3-year Contract Shall Be Made. Hence, Renewable Yearly After Evaluation Report And Deliberation Among The End Users. > Free Of Charge Technical Services Of Company Engineer Which Must Be Available And Responsive To Any Of The Problems Or Concerns Of The Machine 24/7, Conduct Regular Monthly Machine's Calibration And Preventive Maintenance. > Machine Provided Must Be Lis Ready. > Supplier Must Shoulder Connectivity Fee/charges For Lis Services And Coordinate With Astmmc Lis Provider For The Lis Connection. > Machine Should Be Supplemented With A Desktop Computer, Printer, Avr And Ups And Other Accessories To Function And Sturdy Table If Designed As Table Top Machine Specifications: > Analytical Principle/system Description: Urine Flow Cytometry/flow Imaging Technique, Photoelectric Colorimetry > Throughput: At Least 100 Samples/hour > With Autoloader > Sample Volume: At Least 3 Ml > Built-in Reagent Strip Reader/ Chemical Testing And Visual Urine Sediment Reader In One Machine > User Friendly Design; Simple Operation And Convenient Maintenance > Urine Strip Bottle Must Have Color Reaction Comparator For Manual Method > Reagent Strip Parameters/chemical Testing (at Least 12 Parameters): 1. Urobilinogen 2. Bilirubin 3. Ketone 4. Creatinine 5. Blood 6. Microalbumin 7. Nitrite 8. Leukocyte 9. Glucose 10. Specific Gravity 11. Ph 12. Protein > Microscopic Testing / Urine Sediment Visual Reading: 1. Rbc 2. Wbc 3. Non-squamous Epithelial Cells 4. Squamos Epithelial Cells 5. Bacteria 6. Mucus 7. Urine Crystals 8. Casts 9. Yeast Cells Urine Strips, At Least 12 Parameters (100 Strips/bottle) 125 Bottle 8,200.00 1,025,000.00 5 Working Days After Issuance Of A Call-off Or Any Date Determined By The Pe
Contact
Tender Id
8f317c9f-9a2f-3784-b4ed-fab6ed2bc515Tender No
8774342Tender Authority
Adela Serra Ty Memorial Medical Center ViewPurchaser Address
-Website
notices.ps-philgeps.gov.ph