Desk Tenders
Desk Tenders
Airports Authority Of India - AAI Tender
Goods
GEM
Varanasi, Uttar Pradesh
Description: BOQ ITEMS: Sub-Head A (Operation and Maintenance)
Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Terminal Building, ATC Tower, Fire station including AC Operation, Pump Operation, Fire Fighting and alarm systems operation, GLF operation and other ancillary buildings including operation, repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following minimum manpower as per requirement in general shift per day.
(a) Skilled Manpower(Electrician/Technician)-02 Nos. (Reliever Shall be Provided on Weekly Off/Holiday)
(b) Unskilled Manpower(Helper -02 Nos. (Reliever Shall be Provided on Weekly Off / Holiday).
Note-Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs., Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Sub-Station i/c repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance including operation of DG sets of different capacity and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following manpower as per requirement for round the clock operation in three shifts per day.
(a) Skilled (Electrician/Technician)-03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday)
(c) Unskilled(Helper) - 03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday)
Note- Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs., Sub-Head B (Misc RandM works)
Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required..
2.0 TR, 1 Phase, 230 V, 50 Hz Split AC Unit (1st Year), Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required..
2.0 TR, 1Phase, 230 V, 50 Hz Split AC Unit (2nd Year), Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.
(Maintenance to be done through OEM/Authorized dealer/specialized agency.)
Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)-(1st Year), Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.
(Maintenance to be done through OEM/Authorized dealer/specialized agency.)
Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3 Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)- (2nd Year), Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item)
1st Year , Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item)
2nd Year, Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required.
1st Year , Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required.
2nd Year, Annual comprehensive maintenance for RO System( Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item.
1st Year , Annual comprehensive maintenance for RO System (Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item.
2nd Year, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Shield Membrane, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Carbon/Sediment Filter, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
2.5AMP 24VDC SMPS, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
KENT FRT 550, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Kent Choke, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Kent UF 4inch, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Shield Membrane, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Carbon/Sediment Filter, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
2.5AMP 24VDC SMPS, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
KENT FRT 550, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Kent Choke, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Kent UF 4inch, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer)
Ceiling Fan, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer)
Wall Fan / Pedestal fan, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer)
Exhaust Fan, Lifting and lowering of borewell submersible pump of various capacities (up to 3 HP) due to defect in existing pump on urgent basis within a short notices including connection of cables jointing of cables etc. with successful testing and commissioning complete as required., Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer)
1HP, Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer)
3HP, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
CO2 Type- 4.5KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
CO2 Type- 6.5KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
ABC Type 4KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
ABC Type 6KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
ABC Type 5KG Capacity, Dismantling of high wall split type air conditioning unit , re-installation, testing and commissioning of capacity up to 2 TR. air-conditioner units , fixing of existing refrigerant pipe, insulation and existing flexible copper conductor cable between evaporator and condenser units, topping up refrigerant gas etc. complete as required., Servicing of Land T Make, Model- CN-CS 800S1 Air circuit breaker 800 Amp through authorised service dealer of OEM/ specialized agency including carrying out of following works racking out and removal of ACB from switch board, cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of ACB. Cleaning all parts with cleaning agents such as CRC 2-26 checking the various settings within the ACB of contacts, releases etc, checking the hardware for wear and tear, checking of termination and tightness, checking for all hardwares for its presence, replacement of spares / accessories for defective / worn out items (Supply of spares / accessories required for healthiness of ACB are in AAI scope), regreasing of the ACB parts as recommended by OEM, refixing the ACB, testing and observance for normal operation of ACB complete as required. , Servicing/maintenance of existing 11 KV VCB panel (installed in HT panel room- Panel Type- AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019 ) as per recommendation of OEM / Authorized dealer of OEM/ specialized agency.
, Testing for healthiness and carrying out calibration of all relays i/c secondary injection test installed in 11KV HT panel of sub-station and submission of test report and calibration certificate as required. Details of HT panel Panel is - AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019.
Note- Testing and callibrations to be done by OEMs recommended callibrated Kit, by their Er./Technician or by Er./Technician of Authorized dealer of OEM/ specialised agency., Topping up transformer oil including oil filtration/ dehydration and oil sample testing of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019., Oil sample Testing of Transformer oil for 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019 etc. complete as required., Oil filtration and Dehydration i/c oil sample testing before and after of dehydration of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019., Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).
4 KW, Microprocessor Controlled Nasu Make CCR
Sr. No. NS/MPCCR/09/2019/09- (1st Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).
4 KW, Microprocessor Controlled Nasu Make CCR
Sr. No. NS/MPCCR/09/2019/10- (1st Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).
4 KW, Microprocessor Controlled Nasu Make CCR
Sr. No. NS/MPCCR/09/2019/09- (2nd Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).
4 KW, Microprocessor Controlled Nasu Make CCR
Sr. No. NS/MPCCR/09/2019/10- (2nd Year), Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter.
(All the components required for servicing of RCD will be supplied by AAl )
1st Year, Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter.
(All the components required for servicing of RCD will be supplied by AAl )
2nd Year, Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required.
1st Year, Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required.
2nd Year, Rate for Each one rupee Value of work executed from the CPWD DSR (EandM) 2022 Electrical rates.(For example if the quoted rate for this item is Rs.0.90 then the executed DSR-2022 (Electrical) schedule works of value Rs.100000.00 at DSR-2022 (Electrical ) rates, the quoted amount will be Rs.90000.00 and if quoted rate for this item is Rs.1.25 then quoted amount for the same will be Rs.125000.00) .
1st year, Rate for Each one rupee Value of work executed from the CPWD DSR (EandM) 2022 Electrical rates. (For example if the quoted rate for this item is Rs.0.90 then the executed DSR-2022 (Electrical) schedule works of value Rs.100000.00 at DSR-2022 (Electrical ) rates, the quoted amount will be Rs.90000.00 and if quoted rate for this item is Rs.1.25 then quoted amount for the same will be Rs.125000.00) .
2nd year
Closing Date16 Jul 2024
Tender Amount₹ 95 Lac
Border Roads Organisation - BRO Tender
Goods
Publishing and Printing
GEM
Corrigendum : Corrigendum Added
Tinsukia, Assam
Description: CATEGORY: Plain Copier Paper (V2) as per IS 14490 (Q4) , Diaries
Printed - Plain - Register (Q4) , Black Lead Pencils (V2) as
per IS 1375 (Q4) , Manual Pencil Sharpener (V2) (Q3) ,
Metric Steel Scales (V2) as per IS 1481 (Q4) , Metric Scales
(Plastic) for General Purposes as per IS 1480 (Q4) , Roller
Ball Pen (V2) (Q4) , Gel Pen (V3) (Q4) , Ink Refills (V2) (Q4) ,
Permanent Marker Pen (Q4) , Highlighter Pen (Q4) , Sketch
Pen (V2) (Q4) , Fluid Correction Pen (V2) (Q4) , Poker or
AWL as per IS 10375 (Q4) , Self Adhesive Flags (V2) (Q4) ,
Clips, Paper as per IS 5650 (Q4) , Pins, Paper, Straight as
per IS 5653 (Q4) , Stapler Pin / Staples (V2) (Q4) , Dak Pad
(V2) (Q4) , Eraser (Q4) , Pen Stand (V2) (Q4) , Desk Pads -
Writing (V2) (Q4) , Stamp - Pad Ink as per IS 393 (Q4) ,
stamp pads (Q4) , Desktop Calculator - Electronics (Q4) ,
Bond Paper (V2) as per IS 1848 (Part 1) (Q4) , Cleaning
Duster (V2) (Q4) , File Folder Cover (V2) (Q4) , Glue Stick
(V2) (Q4) , Correspondence Envelopes (V2) (Q4) , Gum Tube
50 ml , Fevicol 500 gm , Feviquick tube 20 ml , Magnetic Pin
Clip Holder Dispenser , Tag Nylon long good quality 20 inch
50 Nos in each bundle , Tag Nylon small good quality 6 inch
50 Nos in each bundle , Kangaro Stapler Size 24 oblique 6 ,
Kangaro Stapler Size 10 oblique 4 , Metal Binder Clip Oddy
Size 25 mm pack of 24 pcs , Metal Binder Clip Oddy Size 41
mm pack of 12 pcs , Metal Binder Clip Oddy Size 51 mm
pack of 12 pcs , Plastic Grip Hand Held Auto Lock Paper
Cutter , Pen Style Staple Remover , Transparent Cello Tape
4 inch Width 65 Meters Length , Transparent Cello Tape 0.5
inch Width 65 Meters Length , Transparent Cello Tape 1 inch
Width 60 Meters Length , Transparent Cello Tape 2 inch
Width 65 Meters Length , Tape Brown 4 Inch width 65
Meters Length , Tape Brown 2 Inch width 65 Meters Length ,
Tape Brown 1 Inch width 65 Meters Length , Transparent
Plastic Clipboard Writing Pad , Tape Self Adhesive Red Color
2inch Widthe , Tape Self Adhesive Green Color 2inch Widthe
, Tape Self Adhesive Blue Color 2inch Widthe , OHP
Transparent Sheet A4 Size , GBC Sheet Blue A4 Size , OHP
Transparent Sheet FS Size , GBC Sheet Blue FS Size , Brown
Chart Paper , Chart Sheet White Size 70x56 cm , Chart
Paper Size 70x56 cm , Chart Sheet Extra Thick Glossy Size
70x56 cm , Chart Sheet Red Size 70x56 cm , Chart Sheet
Blue Size 70x56 cm , Chart Sheet Yellow Size 70x56 cm ,
Chart Sheet Green Size 70x56 cm , Phot Glossy Paper Kodak
Size 70x56 cm Pack of 20 Sheets , Edge Binding Tape
Colored Good Quality 12mm , Talc Sheet 100 mtr long ,
Pastle Paper 180 GSM Color Paper A4 Size , Plastic Comb
Binding Spines in Pkts of 100 12 mm , Plastic Comb Binding
Spines in Pkts of 100 14 mm , Plastic Comb Binding Spines
in Pkts of 100 16 mm , Plastic Comb Binding Spines in Pkts
of 100 19 mm , Plastic Comb Binding Spines in Pkts of 100
25 mm , Plastic Comb Binding Spines in Pkts of 100 50 mm ,
Plastic Comb Binding Spines in Pkts of 100 60 mm , Tape
Dispenser Large , Tape Dispenser Medium , Glitter Pens
Colored Set of 10 Pens , Stick File Folder Transparent ,
Plotter Paper Roll 80 GSM 36 inch Wide 45 mtr Long and 2
inch core , Paper Trimmer Machine Metal Body Heavy Duty
Size A3 17 inch , Spiral Binding Machine Avanti A3 Size ,
Comb Binding Machine Avanti A3 Size , Comb Binder FS Size
, Paper Cutter Machine Legal Size , Pedal Dustbin Plastic 12
Ltr , Short Hand Notebook Size 12.5x16 with 160 Pages ,
Engagement Pad 2025
Closing Date11 Nov 2024
Tender AmountRefer Documents
Indian Army Tender
Goods
Paints and Enamels
GEM
Bengaluru, Karnataka
Description: CATEGORY: Add Gel Pen Blue , Add Gel Pen Red , Add Gel Pen Black ,
Refill Add Gel Pen Blue , Refill Add Gel Pen Red , Refill Add
Gel Pen Black , Pilot Pen V5 Blue , Pilot Pen V5 Red , Pilot
Pen V5 Black , Trimax Acid Free Water Proof Gel Pen Blue ,
Gel Pen V7 Blue , Gel Pen V7 Red , Gel Pen V7 Black , Gel
Pen V5 Blue , Gel Pen V5 Red , Gel Pen V5 Black , Gel Pen
V10 Blue , Gel Pen V10 Red , Gel Pen V10 Black , Parker Ink
Pen , Ball Pen Blue , Ball Pen Red , Ball Pen Black , Binder
Clip 25 mm 12 pieces or pkt , Binder Clip 32 mm 12 pieces
or pkt , Binder Clip 41 mm 12 pieces or pkts , Binder Clip 51
mm 12 pieces or pkts , Drawing Pin , Drawing Pin Colour
Plastic Coated , U Clip Coloured Plastic 28 mm 100 pieces or
pkt , U Clip Gem 35 mm 100 pieces or pkt , Steel Scale 30
cm , Plastic Scale 30 cm , Yellow Dusting Cloth 24 x 24 inch
, Eraser , File cover for DO Part II , Writing Pad 100 pages
Cloth binded , Writing Pad 80 pages Sprial binded , Paste it
pad 2 inch x3 Inch , Stick Not Pad 10inchx7.5 inch , Paper
Pin T Shape , Pencil Sharpener , Pencil , Permanent Marker
Blue , Permanent Marker Black , Pocker Wooden ,
Permanent OHP Marker Red , Permanent OHP Marker Black
, Permanent OHP Marker Blue , Single Hole Punch Machine ,
Sketch Pen All Colours , Stamp Pad Small 70 mm x 110 mm
, Stamp Pad Big 160 mm x 97 mm , Pad Ink 30 ml ,
Transparent Tape 0.5inch 60 Mtr , Transparent Tape 1 inch
60 Mtr , Transparent Tape 2 inch 60 Mtr , Tape 2 inch Brown
, Tape 3 inch Brown , Tape 2 inch Transparent , Tape stand
1.6 inch x 2.5 inch , Calculator Small , Calculator Big , Dak
Folder Red , Dak Folder Black , White Bd Marker Pen Black ,
White Bd Marker Pen Blue , Whitener Correction Pen , File
Binder , Pencil Cell AAA , Pencil Cell AA , Scissor Big 200 mm
, Paper cutter small , Paper cutter large , Spiral binding leaf
A4 Blue , Spiral binding leaf A4 Transparent , Spiral binding
ring 32 mm , Spiral binding ring 50 mm , Glue stick 15 gm ,
Fevicol Tube 100gm , Fevicol Tube 200gm , Gum Bottle
300gm , Plastic Cover or display cover For File , Stapler
Small , Stapler Large , Stapler Pin Small , Stapler Pin Large ,
Call Bell , Carbon Paper , Photo Paper , Paper Punching
Machine , Highlighter Yellow or Blue or Green , Tag Green
Big 200 mm , Tag 150 mm , Clip board Omega , Colour flag
set of five 76 mm x 25 mm size 120 sheets , Colour Flag
plastic four strips , Pen and Pencil Stand Wooden ,
Adjustable Acrylic Writing Desk 21 inch x 15 inch , Plastic
Sutli , Padlock 40mm , Padlock 70mm , Room Freshener ,
Paper cutter blade large , Paper cutter blade small , Sketch
Pen Black , Paper Weight , Register 200 pages , Register
300 pages , Register 400 pages , Note Pad Offrs Champion
dairy size 100 pages , Binder Clip 15 mm 12 pieces or pkt ,
Binder Clip 12 mm 12 pieces or pkt , Lamination sheet A4
Size , Drawing sheet Green , Drawing sheet Pink , Drawing
sheet Yellow , Drawing sheet White , Drawing sheet Blue ,
Talc Sheet 60 Inch Width , Envelope 158 x 355 mm ,
Envelope 300 x 250 mm , Envelope Brown 110 x 220 mm ,
Envelope Brown 250 x 325 mm , Envelope Brown 254 x 127
mm , Envelope Brown 280 x 127 mm , Envelope Brown 300
x 100 mm , Envelope White 152 x 107 mm , Envelope DO
White 122 x 176 mm , Envelope DO White 228 x 101 mm ,
Envelope 228 x 101 mm with Cloth , Envelope 250 x 325
mm with Cloth , Envelope 324 x 458 mm with cloth ,
Envelope Laminated 400 x 300 mm Brown
Closing Date22 Nov 2024
Tender AmountRefer Documents
Airports Authority Of India - AAI Tender
Goods
GEM
Corrigendum : Corrigendum Added
Varanasi, Uttar Pradesh
Description: BOQ ITEMS: Sub-Head A (Operation and Maintenance)
Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Terminal Building, ATC Tower, Fire station including AC Operation, Pump Operation, Fire Fighting and alarm systems operation, GLF operation and other ancillary buildings including operation, repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following minimum manpower as per requirement in general shift per day.
(a) Skilled Manpower(Electrician/Technician)-02 Nos. (Reliever Shall be Provided on Weekly Off/Holiday)
(b) Unskilled Manpower(Helper -02 Nos. (Reliever Shall be Provided on Weekly Off / Holiday).
Note-Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs., Periodical Operation and Maintenance of various Electrical and Mechanical Installations of Sub-Station i/c repairs and maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance including operation of DG sets of different capacity and maintenance of records / documentation etc. as per tender specifications, terms and conditions covered under this contract on all days including Saturdays, Sundays and holidays by providing following manpower as per requirement for round the clock operation in three shifts per day.
(a) Skilled (Electrician/Technician)-03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday)
(c) Unskilled(Helper) - 03 Nos. (i.e. 01 No. in each shift for round the clock operation and Reliever Shall be Provided on Weekly Off/Holiday)
Note- Contractor has to provide Reliever on Weekly Offs / Holidays of above required staffs., Sub-Head B (Misc RandM works)
Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required..
2.0 TR, 1 Phase, 230 V, 50 Hz Split AC Unit (1st Year), Annual Comprehensive maintenance of Inverter / Non- Inverter Split type room Air conditioner Units of following capacity, different makes including stabilizer (If any) installed at different locations inclusive of all spares, materials involving repair and maintenance as per manufacture schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required..
2.0 TR, 1Phase, 230 V, 50 Hz Split AC Unit (2nd Year), Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.
(Maintenance to be done through OEM/Authorized dealer/specialized agency.)
Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)-(1st Year), Annual Comprehensive periodical maintenance of VRV type outdoor Air conditioner Units of Following capacity, and Cassette type indoor units of Daikin makes, Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units) installed at terminal building inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations gas charging, fan, fan motors, thermal Insulation, etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including Sunday and holiday etc. as required.
(Maintenance to be done through OEM/Authorized dealer/specialized agency.)
Model No. RXYQ20ARY6 (5Nos. VRV Unit Each 20HP 3 Phase, 380-415V, 50 Hz, with 20 Nos. Indoor Cassette type units)- (2nd Year), Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item)
1st Year , Supply and laying of refrigerant copper piping including top up of gas charging suitable for 1.5TR / 2TR / 2.5TR capacity of different type AC Units, both suction and discharge along with suitable thermal Insulation and suitable necessary accessories for connection complete for shifting/ reinstallation of ACs as per site requirement. (One lengths of suction, discharge piping and length of copper wire shall be measured one meter for this item)
2nd Year, Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required.
1st Year , Annual comprehensive maintenance of water cooler ( Make- Voltas Model- No. VOLTAS WC FS 40/80NP ) installed at terminal building, inclusive of all spares, materials involving repair and maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical, equipment, safety controls and instrumentations, gas charging etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract, providing all necessary consumables complete as required.
2nd Year, Annual comprehensive maintenance for RO System( Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item.
1st Year , Annual comprehensive maintenance for RO System (Make, Kent ELITE PLUS) upto 50 litre capacity including replacement of all defective components and carrying monthly service activity as required. The supply of consumable spares, membrane and filters as mentioned in item 8 is not included in the scope of this item.
2nd Year, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Shield Membrane, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Carbon/Sediment Filter, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
2.5AMP 24VDC SMPS, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
KENT FRT 550, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Kent Choke, 1st Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Kent UF 4inch, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Shield Membrane, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Carbon/Sediment Filter, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
2.5AMP 24VDC SMPS, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
KENT FRT 550, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Kent Choke, 2nd Year
Replacement of following filter/ spare for above RO system etc. complete as and when required.
Kent UF 4inch, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer)
Ceiling Fan, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer)
Wall Fan / Pedestal fan, Rewinding, servicing, repairing of following fans including replacement of worn-out/ defective parts like copper wire, insulation, bearings, capacitors etc., i/c transportation from site to workshop and back to site. (dismantled material/ wire shall be property of tenderer)
Exhaust Fan, Lifting and lowering of borewell submersible pump of various capacities (up to 3 HP) due to defect in existing pump on urgent basis within a short notices including connection of cables jointing of cables etc. with successful testing and commissioning complete as required., Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer)
1HP, Repair and rewinding of following capacity single phase submersible pump motor sets. Job include transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out / defective parts i.e. bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (dismantled material/ wire shall be property of tenderer)
3HP, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
CO2 Type- 4.5KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
CO2 Type- 6.5KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
ABC Type 4KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
ABC Type 6KG Capacity, Refilling of fire extinguisher and Hydraulic pressure Testing (HPT) from authorized center as per Norms of following type and capacity as and when required.
ABC Type 5KG Capacity, Dismantling of high wall split type air conditioning unit , re-installation, testing and commissioning of capacity up to 2 TR. air-conditioner units , fixing of existing refrigerant pipe, insulation and existing flexible copper conductor cable between evaporator and condenser units, topping up refrigerant gas etc. complete as required., Servicing of Land T Make, Model- CN-CS 800S1 Air circuit breaker 800 Amp through authorised service dealer of OEM/ specialized agency including carrying out of following works racking out and removal of ACB from switch board, cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of ACB. Cleaning all parts with cleaning agents such as CRC 2-26 checking the various settings within the ACB of contacts, releases etc, checking the hardware for wear and tear, checking of termination and tightness, checking for all hardwares for its presence, replacement of spares / accessories for defective / worn out items (Supply of spares / accessories required for healthiness of ACB are in AAI scope), regreasing of the ACB parts as recommended by OEM, refixing the ACB, testing and observance for normal operation of ACB complete as required. , Servicing/maintenance of existing 11 KV VCB panel (installed in HT panel room- Panel Type- AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019 ) as per recommendation of OEM / Authorized dealer of OEM/ specialized agency.
, Testing for healthiness and carrying out calibration of all relays i/c secondary injection test installed in 11KV HT panel of sub-station and submission of test report and calibration certificate as required. Details of HT panel Panel is - AES1220VCBP-1D, Sr. No.1-1346-5, Mfg Year 2019.
Note- Testing and callibrations to be done by OEMs recommended callibrated Kit, by their Er./Technician or by Er./Technician of Authorized dealer of OEM/ specialised agency., Topping up transformer oil including oil filtration/ dehydration and oil sample testing of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019., Oil sample Testing of Transformer oil for 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019 etc. complete as required., Oil filtration and Dehydration i/c oil sample testing before and after of dehydration of 500 KVA 11/0.415kv transformer of Make- KOTSONS PRIVATE LIMITED, Serial No. 20190182 Mfg Year 2019., Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).
4 KW, Microprocessor Controlled Nasu Make CCR
Sr. No. NS/MPCCR/09/2019/09- (1st Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).
4 KW, Microprocessor Controlled Nasu Make CCR
Sr. No. NS/MPCCR/09/2019/10- (1st Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).
4 KW, Microprocessor Controlled Nasu Make CCR
Sr. No. NS/MPCCR/09/2019/09- (2nd Year), Annual Maintenance of Micro Processor controlled CCRs of NASU make including repairing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and service the same, including calibration/checking of the protection circuits, insulation monitor circuits and brightness controls of MPCCRs and complete checking, servicing on quarterly basis etc. as required as per the directions of Engineer-in-Charge and submission of test reports etc as per manufacturer recommendations of NASU make (All the components required for servicing of MPCCRs will be provided by AAI).
4 KW, Microprocessor Controlled Nasu Make CCR
Sr. No. NS/MPCCR/09/2019/10- (2nd Year), Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter.
(All the components required for servicing of RCD will be supplied by AAl )
1st Year, Annual maintenece of remote control desk including repairing of the control desk by identifying faults i/c replacing defective components,servicing the same , doing preventive mainlenance , keeping the system in working condition by carrylng out preventive maintenance every quarter.
(All the components required for servicing of RCD will be supplied by AAl )
2nd Year, Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required.
1st Year, Servicing and maintenance i/c calibration and stamping of 200kg Electrical Weight Machine , Stamping to be done from Government Legal metrology once in year and servicing once in six Month as required.
2nd Year, Rate for Each one rupee Value of work executed from the CPWD DSR (EandM) 2022 Electrical rates.(For example if the quoted rate for this item is Rs.0.90 then the executed DSR-2022 (Electrical) schedule works of value Rs.100000.00 at DSR-2022 (Electrical ) rates, the quoted amount will be Rs.90000.00 and if quoted rate for this item is Rs.1.25 then quoted amount for the same will be Rs.125000.00) .
1st year, Rate for Each one rupee Value of work executed from the CPWD DSR (EandM) 2022 Electrical rates. (For example if the quoted rate for this item is Rs.0.90 then the executed DSR-2022 (Electrical) schedule works of value Rs.100000.00 at DSR-2022 (Electrical ) rates, the quoted amount will be Rs.90000.00 and if quoted rate for this item is Rs.1.25 then quoted amount for the same will be Rs.125000.00) .
2nd year
Closing DateCancelled
Tender Amount₹ 95 Lac
Directorate Of Training And Employment Tender
GEM
Corrigendum : Closing Date Modified
Ghazipur, Uttar Pradesh
Description: CATEGORY: ALLEN KEY SET OF 12P (Q3) , PHILIPS SCREW DRIVER SET
OF 5P (Q3) , SPANNER SOCKET WITH SPEED HANDLE T BAR
RATCHET UNIVERSAL SET OF 28P (Q3) , STEEL TOOL BOX
WITH LOCK AND KEY 400 X 200 X 150MM (Q3) , FUEL FEED
PUMP FOR DISEL HAND OPERATED PLUNGER TYPE (Q3) ,
GREASE GUN HEAVE DUTY TROLLEY TYPE 10KG (Q3) ,
AUTOMATIVE OIL PUMP FOR DISMANTLING AND
ASSEMBLING (Q3) , TURBO CHARGER CUT SECTIONAL (Q3) ,
AUTOMOTIVE WATER PUMP OFR DISMANTLING AND
ASSEMBLING (Q3) , WORK BENCH 250 X 120X 60 WITH
4VICES 12CM JAW (Q3) , SYNCHRONOUS GEAR BOX WITH
STAND FOR DISMANTLING AND ASSEMBLY (Q3) , ARBOR
PRESS HAND OPERATED 2TON (Q3) , DIESEL ENGINE
RUNNING CUNDITION STATIONARY TYPE SINGLE CYLINDER
(Q3) , TRANSFOR CASE WITH STAND FOR DISMANTLING
AND ASSEMBL (Q3) , MRI EQUIPMENT (Q3) , KNIFE SWTICH
DPDT FITTED WITH FUSE TERMINALS (Q3) , RUBBER MAT 2
X 4 X 1" (Q3) , METAL RACK 100 X 150 X 45CM (Q3) ,
CRIMPING TOOL 16SQ TO 95 SQ MM (Q3) , CRIMPING TOOL
1.5 SQ TO 16 SQ MM (Q3) , BEARING PULLER INSIDE AND
OUTSIDE (Q3) , LIMIT SWITCH (Q3) , ROTARY SWITCH 16A
440V (Q3) , POWER FACTOR METER DIGITAL 440V 20A
THREE PHASE PORTABLE BOX TYPE (Q3) , LUX METER LCD
READ OUT 0.05 TO 7000 LUMINUS WITH BATTERY (Q3) ,
TACHOMETER DIGITAL PHOTO SENSOR TYPE 10000 RPM
(Q3) , TONG TESTER 0-100A DIGITAL TYPE (Q3) , MEGGER
ANALOG 500V (Q3) , SINGLE PHASE VARIABLE AUTO
TRANSFORMER 0-270V 10A AIR COOLED (Q3) , VARIABLE
AUTO TRANSFORMER 3PHASE 415V (Q3) , SINGLE PHASE
TRANSFORMER CORE TYUPE AIR COOLED 1KVA 240 415V
50HZ (Q3) , MANUAL MOTOR COIL WINDING MACHINE WITH
STEP ARBOR (Q3) , CEILING FAN COIL WINDING MACHINE
250V 50HZ (Q3) , C-CLAMP 200MM (Q3) , C-CLAMP 100MM
(Q3) , 8 LOCKERS DRAWERS (Q3) , SOLAR PANEL WITH
BATTERY 12W (Q3) , DIGITAL IC TRAINER (Q3) , POTENTIAL
TRANSFORMER 415V 50HZ (Q3) , UNIVERSAL SURFACE
GAUGE 225MM (Q3) , COMBINATION SET 300MM RULE
COMPLETE SET (Q3) , MICROMETER OUTSIDE 0-25MM
READING 0.01 (Q3) , MICROMETER OUTSIDE 25-50MM
READING 0.01 (Q3) , MICROMETER OUTSIDE 50-75MM
READING 0.01 (Q3) , MICROMETER INSDIE UP TO 25MM
READING 0.01M (Q3) , DEPTH GAUGE MICROMETER 0 TO
150MM READING 0.01MM (Q3) , DIAL VERNIER CALIPER
200MM READING. 05MM (Q3) , VERNIER BEVEL PROTACTOR
300MM BLADE (Q3) , VERNIEER MICROMETER OUTSIDE 0 TO
25MM LC 0.00 (Q3) , VERNIER MICROMETER OUTSIDE 0 TO
1" LC 0.00 (Q3) , VERNIEER HEIGHT GAGUE WITH DIAL
30MM LC 0.0 (Q3) , SCREW THREAD MICROMETER
INTERCHANGEBLE (Q3) , SINE BAR WITH CENTER 200MM
(Q3) , SLIP GAUGE METRIC SET 87P BOX (Q3) , MORSE
TAPPER SLEEVE 0-1-2, 2-3, 3-4, 4-5 (Q3) , TWIST DRIL
TAPPER SHANK 10 TO 12MM BY 0.5M (Q3) , ALMIRAH 1980 X
910 X 490 (Q3) , VERNIER CALIPER OUTSIDE 200MM (Q3) ,
DUAL DESK POWDER COATED (Q3) , DESKTOP COMPUTER
CORE i5 11TH GENRATIN 512 SSD 8GB RAM 20.5 DISPLAY
(Q3) , MICTROPHONE SYSTEM (Q3) , COMPUTER TABLE 2 X 3
(Q3) , LAPTOP CORE i5 11TH genration 512 ssd 8gb ram
(Q3) , MAGNETIC WHITE BOARD 8 X 4 (Q3) , INTERACTIVE
BOARD (Q3) , LOCKERS 12 DRAWERS (Q3) , BOOK CASE
1980 X 910 X 490 (Q3) , ANTIVIRUS 1USER (Q3) , UPS 1KVA
(Q3) , TIN SMITH BENCH FOLDER 600MM (Q3)
Closing Date27 Jan 2024
Tender Amount₹ 43.8 Lac
This is an estimated amount, exact amount may vary.
DESK OFFICER OPERATIONS Tender
Works
Civil And Construction...+1Civil Works Others
Nizamabad, Telangana
Purchaser Name: DESK OFFICER OPERATIONS | Sbi - Online Tender For Proposed Interior Works For Ravindra Nagar Branch, Rbo Adilabad , Ao Nizamabad
Closing Date20 Nov 2024
Tender Amount₹ 11.9 Lac
HSCC India Limited - HSCC Tender
Goods
Software and IT Solutions
Corrigendum : Closing Date Modified
Ghaziabad, Uttar Pradesh
Tender Id: HSCC/Quotation/Desktop/2023-24 | Price Quotation For Hp Omen 45l Gaming Desktop Pc Gt22-1214in, Specs:- 13th Gen, Intel Core I9 Processor, Windows 11 Home, Nvidia Geforce Rt 4090, 64 Gb Ddr5, 1 Tb Ssd Hard Drive, Nvidia Geforce Rtx 4090 (24 Gb Gddr6x Dedicated), With Ms Office And One Year Antivirus With 3 Year Onsite Warranty From Date Of Purchase.
Closing Date9 Feb 2024
Tender AmountRefer Documents
Assam Electricity Grid Corporation Limited - AEGCL Tender
NA
Tender Id: AEGCL/MD/IT/DESKTOPS/2023/09 Dated:03/01/2024 | Short Tender For Supply, Installation, Configuration And Successful Implementation Of Desktops Along With All Associated Accessories And Post Installation Support For 3 Years At Assam Electricity Grid Corporation Limited Offices.
Closing Date12 Jan 2024
Tender AmountRefer Documents
Vidyasagar University Tender
Software and IT Solutions...+2Electronics Equipment, Electrical and Electronics
West Bengal
Tender Id: e-Tender for supply and installation of HP Tower Desktop with 20 | E-tender For Supply And Installation Of Hp Tower Desktop With 20'' Led Monitor At Vidyasagar University {niet No.: Wb/vu/mid/niet-03/24-25}
Closing Date1 Jul 2024
Tender AmountRefer Documents
3121-3130 of 3129 archived Tenders