Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Nov 2024
Closing Date13 Dec 2024
Tender Amount₹ 47,57,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. Note : Measurement shall be taken after punning down.

39.59

-

-

... More
S&F of sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.

26183

-

-

... More
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 complete all as specified and directed by Engineer- in- Charge.

17455

-

-

... More
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engineer- in- Charge. Cables of the following sizes:- Note Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately.

-

-

-

... More
16 Sqmm 4 core

2000

-

-

... More
35 Sq mm 3.5 core.

1400

-

-

... More
50 Sq mm 3.5 core.

1100

-

-

... More
95 Sq mm 3.5 core.

200

-

-

... More
120 Sq mm 3.5 core.

1000

-

-

... More
185 Sq mm 3.5 core.

50

-

-

... More
S&F of Junction box thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65 (weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands (IP-65) and/or grommets (IP-55). Size of enclosure: (205x255 x112) mm With suitable connecters for 2Ph/1Ph loop in loop out and branch out vibration proof connections complete all as specified and directed by Engineer- in- Charge.

30

-

-

... More
S&F of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS: 694 of size 2.5 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge.

200

-

-

... More
S&F of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS: 694 of size 06 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge.

200

-

-

... More
S&F of LED Flood lights 50 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge.

50

-

-

... More
S&F of LED Flood lights 120 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge.

40

-

-

... More
S&F of 90 Watt LED street light fittings made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge. Make : Crompton Greaves Model No. LFLN-120-CDL/60-M or equivalent in Havells / Bajaj / Philips as approved by GE.

75

-

-

... More
M&L for GI Tubes of size 50 mm dia light grade, galvanised, with all fitting, laid in trenches for protection of cable in road /drain crossing complete all as specified and directed by Engineer- in- Charge.

50

-

-

... More
Supply & installation of steel tubular swaged poles type 410 SP-31 (9 mtr long) of apprx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and as directed by Engineer-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil, PCC foundation 1:4:8 type D-2, PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 m long for fixing of street light fitings. The steel pole shall be painted by bituminous paint total length inside and up to planting depth outside.

16

-

-

... More
M&L for Boring of holes under road, pavement, hard standing by trenchless technology including 150 mm dia HDPE pipe suitable for 0.6 mpa working pressure. Note :- The quoted rate shall deemed to be included of taking permission from concerned authority like Army Signal and other utility authority and any damage done during execution of work and the same will be repaired/replaced by the Contractor.

45

-

-

... More
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by Engineer- in- Charge and shown in electrical plate number 3 of MES SSR part-I (1991).

15

-

-

... More
S&F of 10 W twister IP 65 Rated LED Bollard with robust design and efficient light distribution (garden lights) and pole base cover aestetocally designed decorative pole base cover, enhancing the appearance of the pole complete all as specified and directed by Engineer- in- Charge. Note- The cost of excavation and PCC 1:3:6, type C-1 for foundation of size (20x20x20cm) required for post top light pole is deemed to be included in the quoted rate.

30

-

-

... More
S&F of 40 W led post top crown HLYT-08 IP 65 LED post top die cast aluminium with stainless steelpins and toggle. reflector high quality anodized aluminium diffuser cover & power led (garden lights) Make HI-LITE and pole base cover aestetocally designed decorative pole base cover, enhancing the apearance of the pole complete all as specified and directed by Engineer- in- Charge. Note- The cost of excavation and PCC 1:3:6, type C-1 for foundation of size (20 x 20 x 20cm) required for post top light pole is deemed to be included in the quoted rate.

38

-

-

... More
Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 200A, factory made, CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4, type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) MCCB 125 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (c) spreader Link- 01 set( 06 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) Set of CT of ratio - 125/05 Amps (g) 3 pole power contractor, type MNX 110 having 2 NO + 2 NC - 01 NO (h) Astro timer -1 No (j) A/O/M selector switch - 1 Nos (k) Control fuse with base - 7 Nos Outgoing :- (a) 100A FP 25 KA MCCB -1 No

2

-

-

... More
Note:-. 1. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The contractor must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following: i) Degree of protection of system ii) Temperature Rise Limit iii) Dielectric Properties iv) Short Circuit Withstand Strength v) Effectiveness of protective circuit vi) Clearance and creepage distance vii) Mechanical Operation 2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent. 3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. 4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. 5.The quoted rate includes the excavation, earth work and required base for fixing the complete panel.

-

-

-

... More
Supplying, fabrication, installation, testing and commissioning in replacement of Bus bar panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 200A, factory made, CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) MCCB 160 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (C) spreader Link- 01 set( 08 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) set of CT of ratio - 160/05 Amps (g) Control Fuse with base- 6 Nos.

4

-

-

... More
Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 630A, factory made, CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) Change over 400 Amps 4 Pole - 01 No (b) Rotary handle- 01 No (C) spreader Link- 01 set( 08 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) set of CT of ratio - 400/05 Amps Outgoing. (a) 400A FP 36 KA MCCB - 01 No (b) 250A FP 36 KA MCCB - 01 No (c )125A FP 36 KA MCCB - 01 No (d) Rotary handle- 03 No

1

-

-

... More
Note:-. 1. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The contractor must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following: i) Degree of protection of system ii) Temperature Rise Limit iii) Dielectric Properties iv) Short Circuit Withstand Strength v) Effectiveness of protective circuit vi) Clearance and creepage distance vii) Mechanical Operation 2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent. 3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. 4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. 5.The quoted rate includes the excavation, earth work and required base for fixing the complete panel.

-

-

-

... More
Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 630A, factory made, CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) MCCB 400 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (C) spreader Link- 01 set( 08 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) set of CT of ratio - 400/05 Amps Outgoing. (a) 100A FP 25 KA MCCB -2 No (b) 160A FP 36 KA MCCB -3 No (c )200A FP 36 KA MCCB -3 No (d) Rotary handle- 08 No

1

-

-

... More
Note:- 1. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The contractor must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following: i) Degree of protection of system ii) Temperature Rise Limit iii) Dielectric Properties iv) Short Circuit Withstand Strength v) Effectiveness of protective circuit vi) Clearance and creepage distance vii) Mechanical Operation 2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent. 3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. 4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. 5.The quoted rate includes the excavation, earth work and required base for fixing the complete panel.

-

-

-

... More
Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 400A, factory made, CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) MCCB 250 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (c) spreader Link- 01 set( 08 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) set of CT of ratio - 250/05 Amps Outgoing. Outgoing. (a) 200A FP 36 KA MCCB -1 No (b) 160A FP 36 KA MCCB -2 No (c) Rotary handle- 03 No

1

-

-

... More
Note:-. 1. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The contractor must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following: i) Degree of protection of system ii) Temperature Rise Limit iii) Dielectric Properties iv) Short Circuit Withstand Strength v) Effectiveness of protective circuit vi) Clearance and creepage distance vii) Mechanical Operation 2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent. 3.The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. 4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. 5.The quoted rate includes the excavation, earth work and required base for fixing the complete panel.

-

-

-

... More
Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 400A, factory made, CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) MCCB 250 Amps 4 Pole,36 KA- 01 No (b) Rotary handle- 01 No (C) spreader Link- 01 set( 08 Pcs) (d) RYB Indicating lamps (e) Digital Voltmeter and ammeter of suitable rating (f) set of CT of ratio - 250/05 Amps Outgoing. (a) 160A FP 36 KA MCCB -2 No (b) 100A FP 36 KA MCCB -2 No (c) Rotary handle- 04 No

1

-

-

... More
Note:-. 1. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The contractor must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following: i) Degree of protection of system ii) Temperature Rise Limit iii) Dielectric Properties iv) Short Circuit Withstand Strength v) Effectiveness of protective circuit vi) Clearance and creepage distance vii) Mechanical Operation 2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent. 3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. 4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. 5.The quoted rate includes the excavation, earth work and required base for fixing the complete panel.

-

-

-

... More
Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :- (a) Incoming :- (i) ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type motorized, front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection-01 No (ii) Voltmeter digital type with 4 way rotary selector swicth -01 No. (iii) Ammeter digital type with 4 way rotary selector switch-01 No. (iv) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three (vi) Aluminium bus bar of rating 1600 Amp- set of four (b) Outgoing (i) MCCB 4 pole, 315 Amps, 50 Hz, 415 Volts, 36 KA with microprocessor release - 02 Nos (ii) MCCB 4 pole, 200 Amps, 50 Hz, 415 Volts, 36 KA with microprocessor release - 03 Nos

1

-

-

... More
(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer.

-

-

-

... More
M&L for Standard cable route indicator 10 cm dia, CI plate 6 mm thick embossed with raised lettering LT cable 1100 volts painted with luminous paint and mounted on angle iron 25x25x3mm and 0.6 mtr long embedded in PCC block 1:2:4 (size 30 cm x 15 cm x 15 cm) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer- in- Charge.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.