Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date9 Jul 2019
Closing Date29 Jul 2019
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(c) Supply only spring charging motor for HT VCB of Make : CG or equivalent as approved.

2

-

-

... More
(d) Supply only Limit switch of type LSMS11, AC 15 , 3A/400 V for HT VCB of Make : CG or equivalent as approved.

2

-

-

... More
(e) Supply only Limit switch of type MU25-I/l 2 16 A/250 V AC for HT VCB of Make : CG or equivalent as approved.

2

-

-

... More
(f) Supply only breaker control switch for HT VCB of Make : CG or equivalent as approved.

2

-

-

... More
(g) Supply only Master relay Relay 110 V DC of Make : CG or equivalent as approved.

2

-

-

... More
(h) Supply only Rail Pole Relay 110 V DC of Make : CG or equivalent as approved.

2

-

-

... More
(i) Supply only Aux. Contact block (VCB) of Make : CG or equivalent as approved.

2

-

-

... More
Disconnecting and opening of RMU and removal of all connections with due care for serviceability of its parts and reconnect the HT connection after repairing and serviceability of RMU including with repalcement of tripping coil, bushing set, relay, Indicators (RYB) set, selector switch, refilling of SF6 gas, complete all as specified and directed. Make : CG lucy Note : Breakdown complaints on external electric network shall be completed within 48 hrs without any delay. Necessary repairs/ replacement will be reacted on urgent basis, no delay action shall be applicable during the breakdown conditions.

1

-

-

... More
Taking out the existing transformer from site and transporting to workshop for servicing and repairing including loading, unloading and handling to carry out the following repairs and refixing the same after repairing , installation , testing and commissioning at its existing location complete all as specified and directed . (a) Decant the transformer oil and cheking of all parts for repair/ replacement of parts of cap 1000 KVA capacity of distribution transformer 11/0.440 KV . (b) Rewinding of coils all as per its original stranded specifications by appropiate size/gauge copper conductor and with HT/LT necessary insulation materials. (c) Replacement of HT 11 KV bushing with brass terminal, neoprene rubber gasket and washers etc complete. (d) Replacement of LT bushing with brass terminal, neoprene rubber gasket and washers etc complete (e) Replacement of Transformer oil up to conservator level marking with new oil as per IS 335 having dielectric strength not less than 40 KV at 2.5 mm gap (f) Replacement of silica Jel in existing transformer breathers. (g) Replacement of HT 11 KV off-load tap changing assembly complete. (h) Painting of Transformer body complete with one coat of Simense grey paint with spray paint all as directed by the Engineer-in-charge. (i) Filtration of transformer oil of the transformer at site by providing filtration machine at site. Note : (i) Breakdown complaints on external electric network shall be completed within 48 hrs without any delay. Necessary repairs/ replacement will be reacted on urgent basis, no delay action shall be applicable during the breakdown conditions and accessories or components to be provided for replacement shall be Measured and paid separately. (ii) The cost of work from sl no. (a) to (i) above shall deemed to be included in quoted rate of this item.

1

-

-

... More
All as above item No : 12 above but Cap 630 KVA

1

-

-

... More
Dehydration/filtration of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition including testing of transformer oil before and after filtration by means of oil testing machine, keeping the electrodes at 2.5 mm gap and to achieve die electric strength of filtered oil 50 KV and above complete all as specified and directed.

340

-

-

... More
Supply and topping up/replaced transformer oil conforming to IS : 335 and withstand dielectric strength of 60 KV (when tested with 2.5 Gap electrode) complete all as specified and directed. Make: Savita or equivalent as approved.

620

-

-

... More
Supplying, laying, jointing, testing and commissioning LT, XLPE insulated armoured, heavy duty aluminium conductor electric cable 1100 Volts grade, cross sectional area 240 Sqmm, 3.5 core including taking out old existing cable in trench/wall/feeder connections complete all as specified and directed.

210

-

-

... More
All as per item No 16 but 3.5 core 185 sqmm.

160

-

-

... More
All as per item No 16 but 3.5 core 150 sqmm.

220

-

-

... More
All as per item No 16 but 3.5 core 35 sqmm.

245

-

-

... More
All as per item No 167 but 3.5 core 25 sqmm.

580

-

-

... More
All as per item No 16 but 4 core 16 sqmm.

760

-

-

... More
S&F in replacement with new HT Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed.

3

-

-

... More
S&F in replacement with new HT Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed.

3

-

-

... More
M&L 80mm bore steel tubing light grade, galvanized with all fitting laid in trenches/poles including taking out/down 80mm bore steel tubing with fittings complete all as specified and directed.

110

-

-

... More
All as per item 24 above but 40 mm bore size.

90

-

-

... More
S&F MCCB 3 pole suitable for AC 3 phase 415 volt 50 HZ, 400 Amp, 35 KA, with thermal magnetic release fixed on existing LT panel complete all as specified and directed.Make : HPL( load Guard) or equivalent ' Note: Rate quoted deemed to be included of taking down the existing MCCB from panel board and incoming / outgoing cable and fix the new MCCB in position at panel board and incoming / outgoing cable connections of any size/ rating.

4

-

-

... More
All as per item 26 but 250 Amps, 50 KA.Make : HPL( load Guard) or equivalent

6

-

-

... More
All as per item 26 but 200 Amps, 50 KA.Make : HPL( load Guard) or equivalent

6

-

-

... More
All as per item 26 but 125 Amp, 50 KA.Make : HPL( load Guard) or equivalent

7

-

-

... More
All as per item 26 but 100 Amp, 50 KA.Make : HPL( load Guard) or equivalent

8

-

-

... More
S&F in replacement MCB double pole 63 Amp 415 volt 10 KA complete all as specified and directed.

7

-

-

... More
M&L LT 1100 volts straight through joints kit epoxy type of size 16 to 95 sqmm 3.5 core, jointing LT UG cable complete all as specified and directed.

9

-

-

... More
M&L LT 1100 volts straight through joints kit epoxy type of size 120 to 240 sqmm 3.5 core, jointing LT UG cable complete all as specified and directed.

4

-

-

... More
M&L for servicing of feeder pillar box, after dismantling the incoming and outgoing connections from MCCB/ Bus bar and replacement of old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified. Note: (i) Spare parts such as terminals, lugs, nut bolts, insulators etc will be measured and paid under respective item in the schedule, (ii) Fixing charge of the spare parts deemed to be included in the rate quoted for this items.

14

-

-

... More
Supply only aluminium lugs of any type / shape of capacity 240 Sqmm

30

-

-

... More
Supply only aluminium lugs of any type / shape of capacity 150 Sqmm

30

-

-

... More
Supply only aluminium lugs of any type / shape of capacity 120 Sqmm

30

-

-

... More
Supply only aluminium lugs of any type / shape of capacity 95 Sqmm

30

-

-

... More
Supply only aluminium lugs of any type / shape of capacity 70 Sqmm

30

-

-

... More
Supply only aluminium lugs of any type / shape of capacity 50 Sqmm

30

-

-

... More
Supply only aluminium lugs of any type / shape of capacity 35 Sqmm

30

-

-

... More
Supply only aluminium lugs of any type / shape of capacity 25 Sqmm

30

-

-

... More
Supply only aluminium lugs of any type / shape of capacity 16 Sqmm

30

-

-

... More
Supply only GI Nuts, bolts, screws, washers of required sizes

50

-

-

... More
Supply only bus bar Insulators Epoxy type as required at site min size 45mm x 50 mm dia complete all as specified and as directed.

60

-

-

... More
Supplying and laying unreinforced precast cement concrete cable covers,ISI Marked Class HV, Flat, Type - 1, of size 300 mm X 180 mm X 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface including taking down complete all as specified and as directed.

1400

-

-

... More
Supplying, laying and commissioning of HT XLPE cables, insulated, screened, PVC bedded, galvanized steel strip armoured, earthed, electric power cable with Aluminium conductor, 11 KV grade, 3 Core, 240 Sq.mm cross sectional area laid in trenches / fixed on poles including taking up/down old cables complete all as specified and as directed. Note: Earth work,excavation,cable covers and sand cushioning shall be measured and paid separately.

185

-

-

... More
Material and Labour for heat shrinkable HT, 11 KV cable straight through joint suitable for 11 KV, 3 Phase, AC, 50 Hz, 3 Core, Size of 50 to 95 Sq.mm XLPE Cable including jointing materials,including taking down old unserviceable joints etc complete all as specified and as directed .

6

-

-

... More
Material and Labour for heat shrinkable HT, 11 KV cable straight through joint suitable for 11 KV, 3 Phase, AC, 50 Hz, 3 Core, size of 120 to 240 Sq.mm XLPE Cable including jointing materials,including taking down old unserviceable joints etc complete all as specified and as directed .

3

-

-

... More
M & L preparation of old painted steel surface by cleaning, removing rust, grease and apply one coat of synthetic enamel paint of approved shade with Spray painting machine outside/inside surface of the feeder pillar box / LT Panels Outdoor / Indoor type complete with prior permission of Engineer in Charge. Base frame shall be painted with Black enamel paint including Numbering of Panel/ Feeder pillar complete all as specified and as directed.

14

-

-

... More
M & L Bakelite strip connector, 4 way, 100 Amp cap including electrical connections and taking down old item complete all as specified and as directed.

10

-

-

... More
M & L in replacement LT danger notice board of size 20x15 cm made of aluminium sheet 1 mm thick fixed with Nut / bolts and washers or riveting on LT panels/ feeder pillar boxes with vitreous enamelled white back ground, with letters ,figures and conventional skull and bones in signal red colour complete all as specified and as directed.

17

-

-

... More
M & L in replacement HT danger notice board of size 25x20 cm made of aluminium sheet 1 mm thick fixed with Nut / bolts and washers or riveting on LT panels/ feeder pillar boxes with vitreous enamelled white back ground, with letters figures and conventional skull and bones in signal red colour complete all as specified.

5

-

-

... More
S & F in replacement LED type R/Y/B/G indicating lamp complete all as specified and as directed. Make: C & S / Philips / Crompton / Havells / L&T

42

-

-

... More
S & F selector switch suitable for Voltmeter 3 phase, 415V, AC in existing panel including taking down old item complete all as specified and as directed.. Make L&T Cat No :61312 SAB13TDYR / C&S or equivalent as approved.

10

-

-

... More
S & F selector switch suitable for Ammeter 3 phase, 415V, AC in existing panel including taking down old item complete all as specified and as directed. Make L&T Cat No :61325 SAB13TDYR / C&S or equivalent as approved.

10

-

-

... More
S & F aluminium bus bar of required size, shape, length and making drill for fixing in LT panel /feeder pillar/change over switch etc including taking down old item complete all as specified and as directed.

86

-

-

... More
S&F Volt meter 3 phase, 415 V, 0-500 volt in existing panel including wiring from bus bar to volt meter terminals including taking down complete all as specified and as directed.

11

-

-

... More
S&F Ammeter 0-200 Amp 3 phase, 415 V in existing panel including wiring from bus bar to volt meter terminals including taking down complete all as specified and as directed.

10

-

-

... More
S&F current Transformer coil of rating from 100/5 to 400/5 CT ratio in existing panel including taking down ccomplete all as specified and as directed. Make : AE / Kappa

10

-

-

... More
S&F earth continuity conductor or main earthing lead of Galvanised iron strip of size 25 x 4 mm, fixed on floor/ wall with supporting insulators / laid in trench from existing earth test point including taking down old items complete all as specified and as directed.

50

-

-

... More
Dismantling and taking down HPSV 150 Watt street light fittings from 9 metre height pole for repair or replacement of burnt/ worn out accessories and repairing and refixing the same including treaming the area from bushess, grass etc all around one meter area of pole complete all as specified and as directed. Note:(i) T&P for Dismantling deemed to be included in the unit rate. (ii) Accessories or components to be provided for replacement shall be Measured and paid separately as ' supply only'.

140

-

-

... More
Supply only HPSV Lamp tubular 150Watt,complete all as specified and as directed.

80

-

-

... More
Supply only Ignitor suitable for 150 W HPSV street light fittings complete all as specified and as directed.

65

-

-

... More
Supply only copper wound ballast suitable for 150 Watt HPSV street light fittings complete all as specified and as directed.

70

-

-

... More
Supply only Porcelin holder thread type suitable for 150W HPSV fittings complete all as specified and as directed.

60

-

-

... More
Supply and fix in replacement junction box made from SMC/FRP sheet ready made of size 300 X 200 X 100 mm having 100 A capacity for RYB and neutral with aluminum busbar including all necessary insulators fix to Box and MCB SP 6 Amp 10 KA 240V with aluminium lugs - 01 No with 4 way connector fixed to Pole /Wall with MS clamp 25 X 5 mm with the help of suitable nuts and bolts complete all as specified and as directed. Make : Sintex or equivelant of Make Legrand

170

-

-

... More
Supply and fix in replacement 3 Pole contactor MNX 18, including necessary connections for incomming and outgoing connections complete all as specified and as directed. .Make : L & T Catprt No : CS94100 or equivalent.

9

-

-

... More
Supply and fix in replacement Timer for 24 hrs including necessary wiring from contactor and supply connections complete all as specified and as directed. Make:L&T GIC Cat part No :J648B1 or equivalent.

9

-

-

... More
Supply and fixing in replacement MS kiosk box made out from 2 mm thick MS sheet including busbar TPN 4 strip 63 A capacity and one MCB SP 6 Amp for street light fitting to be mounted on pole with 2 nos 25x3 mm flat iron clamps and shutter to be opened and closed vertically with ball locking system size of box 200x150x100 mm complete with two coats of synthetic enamel paint of approved colour over one coat of red oxide primar complete all as specified and directed.

8

-

-

... More
Supply and fixing in replacement of 90 watt LED fitting for street light on pole complete with electronic drivers and other accessories prewired complete all as specified and directed.

38

-

-

... More
Supply & laying Sub class ‘B’ bricks for cable protection including taking out old bricks complete all as specified and directed.

11000

-

-

... More
M&L for scrapping/removing rusted particals on surface of existing single swan neck steel tublar electric street light pole including nut and bolts after cleaing applying two coats of aluminium paint including writing standered size of numbering of pole and making alternate strip black and yellow with sythetic enamle paint from coping of pole to height up to 1.2metre complete all as specified and directed.

185

-

-

... More
Excavation in trenches not exceeding 1.5 mtr deep and not exceeding 1.5 mtr in width in soft/loose soil and getting out complete all as specified and directed.

630

-

-

... More
Returning filling incl leveling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified & directed .

420

-

-

... More
Removal of surplus soil to a distance n.exc 50 m and deposited where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.

210

-

-

... More
M&L for sand cushioning for cable protection etc in trenches, complete all as specified and directed.

95

-

-

... More
Supply and laying 50 mm bore GI tubing light grade with necessary fittings such as bend, tee,elbow etc in trenches/fixed on wall including taking up/down complete all as specified and directed.

20

-

-

... More
Supply and erecting of steel tubular swaged pole single swan neck bent to shape complete with cast iron base plate bolts and nuts and screws, 410 SP 31( 9 mtr long) complete suitable for street light fitting complete all as specified and directed.

5

-

-

... More
Supply and fixing passing through cable 3 core PVC insulated unsheathed multistranded copper conductor of size 2.5 Sqmm from junction box to street light fittingcomplete all as specified and directed.

210

-

-

... More
M&L for earthing complete with GI earth plate electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 Mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 Mtrs below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI wire 4 mm dia by means of bolts, nuts, chuck nuts, and washers and protected by medium grade 50 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering , including funnel, wire mesh, 75 mm thick RCC pit cover (1:2:4 type B-1 using 20 mm graded stone aggregate) with and including 8 mm dia TMT bars @ 100 mm centre to centre both ways ,PCC chamber pit with PCC 1:2:4 type B-1 ( including necessary form work,excavation and earth work, disposal of surplus soil two a distance not exc. 50 Mtrs) complete all as specified and shown in SSR – Part I 2009. NOTE :-1. PCC pit shall be provided at least 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipe and fittings, junction, elbow etc shall be deemed to be included in the unit rate.

15

-

-

... More
M&L for earthing complete with GI earth plate electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 Mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 Mtrs below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI but using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, chuck nuts, and washers and protected by medium grade 50 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering , including funnel, wire mesh, 75 mm thick RCC pit cover (1:2:4 type B-1 using 20 mm graded stone aggregate) with and including 8 mm dia TMT bars @ 100 mm centre to centre both ways ,PCC chamber pit with PCC 1:2:4 type B-1 ( including necessary form work,excavation and earth work, disposal of surplus soil two a distance not exc. 50 Mtrs) complete all as specified and shown in SSR – Part I 2009. NOTE :-1. PCC pit shall be provided at list 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipe and fittings, junction, elbow etc shall be deemed to be included in the unit rate.

9

-

-

... More
M&L in replacement Mild steel plates, plain or chequered of required thickness complete all as specified and directed.

260

-

-

... More
M&L in replacement rubber Insulating protective mat ,size 1950 X 950 X 20 mm complete all as specified and directed.

5

-

-

... More
M&L for PCC 1:4:8 type D-2 using 40 mm grade stone aggregate as in foundation concrete for pole complete all as specified and directed

5

-

-

... More
M&L for PCC 1:2:4 type B-1 using 20 mm grade stone aggregate as in foundation concrete for pole including finishing the exposed surface without using extra cement complete all as specified and directed

6

-

-

... More
M & L for 60 mm thick M-35 Grade Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 complete all as specified and directed

30

-

-

... More
M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed

2

-

-

... More
M & L for Overhauling of water pump for 100 KVA DG set including replacement of bushess,washers,seal,bearings,impellers complete all as specified and directed

1

-

-

... More
M & L in replacement Fan belt for water pump suitable for 100 KVA DG set complete all as specified and directed

1

-

-

... More
M & L in replacement Hose pipe including clamps suitable for 100 KVA DG set radiator to water intake complete all as specified and directed

1

-

-

... More
M&L for Calibration/setting of timing to FIP for 100 KVA DG set including setting of all necessary items such as rotory piston,rings,springs etc complete all as specified and directed

1

-

-

... More
M&L in replacement of injectors/nozzles for 100 KVA DG set complete all as directed by Engineer-in-Charge.

4

-

-

... More
M&L for taking out and servicing of Radiator with approved chemical of 100 KVA DG set and refixing the same including minor repairs and maintenance such as seal,nut and bolts,washers complete all as specified and directed

1

-

-

... More
M & L in replacement diesel primary and secondry filter element with O ring suitable for 100 KVA DG Set complete all as specified and directed. Make: Greaves cotton

2

-

-

... More
M & L in replacement Oil primary and secondry filter with O ring suitable for 100 KVA DG Set complete all as specified and directed.

2

-

-

... More
M & L Engine OIL for topping up suitable for 100 KVA DG Set complete all as specified and directed.

4.5

-

-

... More
M & L in replacement Air filter element suitable for 100 KVA DG Set complete all as specified and directed.

1

-

-

... More
M & L in replacement HEX SCREW suitable for 100 KVA DG Set complete all as specified and directed.

0.5

-

-

... More
M & L in replacement FIP High pressure pipe suitable for 100 KVA DG Set complete all as specified and directed.

1

-

-

... More
M & L in replacement fuel pipe M14 BANJO 1100 L, RB suitable for 100 KVA DG Set complete all as specified and directed.

1

-

-

... More
M & L in replacement turbo oil drain pipe (4G11TAG3) suitable for 100 KVA DG Set complete all as specified and directed.

1

-

-

... More
M & L in replacement turbo oil inlet pipe side open suitable for 100 KVA DG Set complete all as specified and directed.

1

-

-

... More
M&L in replacement of gasket cylinder suitable for 100 KVA DG Set incl taking down Cylinder head cleaning carbon with help of chemical, polishing valves ,adjustment of required spring action,fixing of new gasket and refixing of cylinder head and tighting complete all as specified and directed.

1

-

-

... More
M&L in replacement Batteries DC, 12V, 180 AH, lead acid duly initial charged complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement Volt meter 0-500 Volt in existing panel including wiring from bus bar to volt meter terminals and fix the wiring with existing control wiring complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement Ammeter 0 - 100Amp in existing panel with necessary wiring from CT to Ammeter and fix the wiring in existing set of control wiring complete all as specified and directed.

1

-

-

... More
M & L in replacement asbestos rope at silencer of DG Set of any capacity/ Make to be fix on pipe after removing existing unserviceble rope complete all as specified and directed.

5

-

-

... More
M & L for Cleaning the fuel tank, after taking the shut down of DG set in all respects and drain out fuel from tank collect in suitable container as directed and cleaning the tank upto bottom and refill the fuel after cleaning and start test/Run the DG set complete all as specified and directed.

2

-

-

... More
M&L for Excavation/boring by High drilling machine for cable laying under the road minimum depth 0.6 mtr from the road surface for crossing at certain required areas, laying cable through the GI pipe without any distrubence to the road surfaces complete all as specified and directed. NOTE: (i) The cost of all necessary T&P required for the work are deemed to be included in qouted rate of this item. (ii) GI pipe shall be measued and paid separetly under respective item.

15

-

-

... More
M&L for preperation of plaster surfaces and applying two coat of cement base paint on coping of steel pole complete all as specified and directed.

170

-

-

... More
Deduct Credit: for demolished/dismantled material of (-) Rs 191546.00(Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.